首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A limitation in the use of invasive coronary diagnostic indexes is that fluctuations in hemodynamic factors such as heart rate (HR), blood pressure, and contractility may alter resting or hyperemic flow measurements and may introduce uncertainties in the interpretation of these indexes. In this study, we focused on the effect of fluctuations in HR and area stenosis (AS) on diagnostic indexes. We hypothesized that the pressure drop coefficient (CDP(e), ratio of transstenotic pressure drop and distal dynamic pressure), lesion flow coefficient (LFC, square root of ratio of limiting value CDP and CDP at site of stenosis) derived from fluid dynamics principles, and fractional flow reserve (FFR, ratio of average distal and proximal pressures) are independent of HR and can significantly differentiate between the severity of stenosis. Cardiac catheterization was performed on 11 Yorkshire pigs. Simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual sensor-tipped guidewire for HR < 120 and HR > 120 beats/min, in the presence of epicardial coronary lesions of <50% AS and >50% AS. The mean values of FFR, CDP(e), and LFC were significantly different (P < 0.05) for lesions of <50% AS and >50% AS (0.88 ± 0.04, 0.76 ± 0.04; 62 ± 30, 151 ± 35, and 0.10 ± 0.02 and 0.16 ± 0.01, respectively). The mean values of FFR and CDP(e) were not significantly different (P > 0.05) for variable HR conditions of HR < 120 and HR > 120 beats/min (FFR, 0.81 ± 0.04 and 0.82 ± 0.04; and CDP(e), 95 ± 33 and 118 ± 36). The mean values of LFC do somewhat vary with HR (0.14 ± 0.01 and 0.12 ± 0.02). In conclusion, fluctuations in HR have no significant influence on the measured values of CDP(e) and FFR but have a marginal influence on the measured values of LFC. However, all three parameters can significantly differentiate between stenosis severities. These results suggest that the diagnostic parameters can be potentially used in a better assessment of coronary stenosis severity under a clinical setting.  相似文献   

2.
Functional diagnostic parameters such as Fractional Flow Reserve (FFR), which is calculated from pressure measurements across stenosed arteries, are often used to determine the functional severity of coronary artery stenosis. This study evaluated the effect of arterial wall-stenosis compliance, with limiting scenarios of stenosis severity, on the diagnostic parameters. The diagnostic parameters considered in this study include an established index, FFR and two recently developed parameters: Pressure Drop Coefficient (CDP) and Lesion Flow Coefficient (LFC). The parameters were assessed for rigid artery (RR; signifying high plaque elasticity), compliant artery with calcified plaque (CC; intermediate plaque elasticity) and compliant artery with smooth muscle cell proliferation (CS; low plaque elasticity), with varying degrees of epicardial stenosis. A hyperelastic Mooney-Rivlin model was used to model the arterial wall and plaque materials. Blood was modeled as a shear thinning, non-Newtonian fluid using the Carreau model. The arterial wall compliance was evaluated using the finite element method. The present study found that, with an increase in stenosis severity, FFR decreased whereas CDP and LFC increased. The cutoff value of 0.75 for FFR was observed at 78.7% area stenosis for RR, whereas for CC and CS the cutoff values were obtained at higher stenosis severities of 81.3% and 82.7%, respectively. For a fixed stenosis, CDP value decreased and LFC value increased with a decrease in plaque elasticity (RR to CS). We conclude that the differences in diagnostic parameters with compliance at intermediate stenosis (78.7-82.7% area blockage) could lead to misinterpretation of the stenosis severity.  相似文献   

3.
Myocardial fractional flow reserve (FFR(myo)) and coronary flow reserve (CFR), measured with guidewire, and quantitative angiography (QA) are widely used in combination to distinguish ischemic from non-ischemic coronary stenoses. Recent studies have shown that simultaneous measurements of FFR(myo) and CFR are recommended to dissociate conduit epicardial coronary stenoses from distal resistance microvascular disease. In this study, a more comprehensive diagnostic parameter, named as lesion flow coefficient, c, is proposed. The coefficient, c, which accounts for mean pressure drop, Delta p, mean coronary flow, Q, and percentage area stenosis, can be used to assess the hemodynamic severity of a coronary artery stenoses. Importantly, the contribution of viscous loss and loss due to momentum change for several lesion sizes can be distinguished using c. FFR(myo), CFR and c were calculated for pre-angioplasty, intermediate and post-angioplasty epicardial lesions, without microvascular disease. While hyperemic c decreased from 0.65 for pre-angioplasty to 0.48 for post-angioplasty lesion with guidewire of size 0.35 mm, FFR(myo) increased from 0.52 to 0.87, and CFR increased from 1.72 to 3.45, respectively. Thus, reduced loss produced by momentum change due to lower percentage area stenosis decreased c. For post-angioplasty lesion, c decreased from 0.55 to 0.48 with the insertion of guidewire. Hence, increased viscous loss due to the presence of guidewire decreased c compared with a lesion without guidewire. Further, c showed a linear relationship with FFR(myo), CFR and percentage area stenosis for pre-angioplasty, intermediate and post-angioplasty lesion. These baseline values of c were developed from fluid dynamics fundamentals for focal lesions, and provided a single hemodynamic endpoint to evaluate coronary stenosis severity.  相似文献   

4.
Functional severity of coronary stenosis is often assessed using diagnostic parameters. These parameters are evaluated from the combined pressure and/or flow measurements taken at the site of the stenosis. However, when there are functional collaterals operating downstream to the stenosis, the coronary flow-rate increases, and the pressure in the stenosed artery is altered. This effect of downstream collaterals on different diagnostic parameters is studied using a physiological representative in vitro coronary flow-loop.The three diagnostic parameters tested are fractional flow reserve (FFR), lesion flow coefficient (LFC), and pressure drop coefficient (CDP). The latter two were discussed in recent publications by our group (Banerjee et al., 2008, Banerjee et al., 2007, 2009). They are evaluated for three different severities of stenosis and tested for possible misinterpretation in the presence of variable collateral flows. Pressure and flow are measured with and without downstream collaterals. The diagnostic parameters are then calculated from these readings.In the case of intermediate stenosis (80% area blockage), FFR and LFC increased from 0.74 to 0.77 and 0.58 to 0.62, respectively, for no collateral to fully developed collateral flow. Also, CDP decreased from 47 to 42 for no collateral to fully developed collateral flow. These changes in diagnostic parameters might lead to erroneous postponement of coronary intervention. Thus, variability in diagnostic parameters for the same stenosis might lead to misinterpretation of stenosis severity in the presence of operating downstream collaterals.  相似文献   

5.
Diagnosis of the ischemic power of epicardial stenosis with concomitant microvascular disease (MVD) is challenging during coronary interventions, especially under variable hemodynamic factors like heart rate (HR). The goal of this study is to assess the influence of variable HR and percent area stenosis (%AS) in the presence of MVD on pressure drop coefficient (CDP; ratio of transstenotic pressure drop to the distal dynamic pressure) and lesion flow coefficient (LFC; ratio of %AS to the CDP at the throat region). We hypothesize that CDP and LFC are independent of HR. %AS and MVD were created using angioplasty balloons and 90-μm microspheres, respectively. Simultaneous measurements of pressure drop (DP) and velocity were done in 11 Yorkshire pigs. Fractional flow reserve (FFR), CDP, and LFC were calculated for the groups HR < 120 and HR > 120 beats/min, %AS < 50 and %AS > 50, and additionally for DP < 14 and DP > 14 mmHg, and analyzed using regression and ANOVA analysis. Regression analysis showed independence between HR and the FFR, CDP, and LFC while it showed dependence between %AS and the FFR, CDP, and LFC. In the ANOVA analysis, for the HR < 120 beats/min and HR > 120 beats/min groups, the values of FFR (0.82 ± 0.02 and 0.82 ± 0.02), CDP (83.15 ± 26.19 and 98.62 ± 26.04), and LFC (0.16 ± 0.03 and 0.15 ± 0.03) were not significantly different (P > 0.05). However, for %AS < 50 and %AS > 50, the FFR (0.89 ± 0.02 and 0.75 ± 0.02), CDP (35.97 ± 25.79.10 and 143.80 ± 25.41), and LFC (0.09 ± 0.03 and 0.22 ± 0.03) were significantly different (P < 0.05). A similar trend was observed between the DP groups. Under MVD conditions, FFR, CDP, and LFC were not significantly influenced by changes in HR, while they can significantly distinguish %AS and DP groups.  相似文献   

6.
The aim of this study was to assess the influence of a second guidewire on the diagnostic accuracy of functional parameters of coronary lesion severity. Sixty-five patients with intermediate coronary lesions underwent myocardial perfusion scintigraphy. Fractional flow reserve (FFR), coronary flow velocity reserve (CFVR), and hyperemic stenosis resistance (HSR) index (HSR = stenosis pressure gradient / velocity) were determined in 77 lesions. Distal pressure and velocity were acquired simultaneously (dual wire) and sequentially (single wire) with two sensor-equipped guidewires. Overall, functional parameters deteriorated from single- to dual-wire assessment. In patients without ischemia, the good diagnostic performance of FFR, CFVR, and HSR deteriorated significantly (P < 0.001) when assessed by dual wires, with an increase in the number of false-positive results. This trend was more pronounced for HSR, since the presence of a second wire reduced maximal velocity and increased the pressure gradient. The presence of two guidewires, especially across a myocardial perfusion scintigraphy-induced nonsignificant lesion, is associated with overestimation of the hemodynamically assessed lesion severity and, therefore, is likely to have a major impact on clinical decision making. This underscores the advantage of a dual-sensor-equipped guidewire for the evaluation of stenosis severity by combined pressure and velocity measurements.  相似文献   

7.
ObjectiveIn this multicentre study, we investigated the long-term prognostic value of intracoronary derived haemodynamic parameters compared with the results of myocardial perfusion scintigraphy (MPS). MethodsPatients (n=191) who were referred for angioplasty of a severe lesion in the presence of an intermediate lesion in another coronary artery were included. MPS was performed to determine the presence of reversible perfusion defects in the area of the intermediate lesion. Coronary flow velocity reserve (CFVR), and additionally fractional flow reserve (FFR; n=129), were determined distal to the intermediate lesion; CFVR ≥2.0 and FFR ≥0.75 were considered negative. ResultsIn total 67 events occurred in 49 patients (3 deaths, 9 MI, 9 CABG, 46 PTCA) during a mean of 793 days follow-up. Event-free survival was 63% for MPS, 79% for CFVR, and 79% for FFR if a negative test result was obtained. The relative risk was 1.2 (not significant) for MPS, 2.2 (p=0.001) for CFVR, and 2.4 (p=0.004) for FFR. ConclusionSelective evaluation of an intermediate lesion using CFVR or FFR allows more adequate risk stratification in patients with multivessel disease than MPS. A CFVR <2.0 or a FFR <0.75 was associated with a significant increase of the occurrence of cardiac events during long-term follow-up, predominantly associated with revascularisation. (Neth Heart J 2007;15:369-74.)  相似文献   

8.
This study aims to investigate the influence of artery wall curvature on the anatomical assessment of stenosis severity and to identify a region of misinterpretation in the assessment of per cent area stenosis (AS) for functionally significant stenosis using fractional flow reserve (FFR) as standard. Five artery models of different per cent AS severity (70, 75, 80, 85 and 90%) were considered. For each per cent AS severity, the angle of curvature of the arterial wall varied from straight to an increasingly curved model (0°, 30°, 60°, 90° and 120°). Computational fluid dynamics was performed under transient physiologic hyperemic flow conditions to investigate the influence of artery wall curvature on the pressure drop and the FFR. The findings in this study may be useful in in vitro anatomical assessment of functionally significant stenosis. The FFR decreased with increasing stenosis severity for a given curvature of the artery wall. Moreover, a significant decrease in FFR was found between straight and curved models discussed for a given severity condition. These findings indicate that the curvature effect was included in the FFR assessment in contrast to minimum lumen area (MLA) or per cent AS assessment. The MLA or per cent AS assessment may lead to underestimation of stenosis severity. From this numerical study, an uncertainty region could be evaluated using the clinical FFR cutoff value of 0.8. This value was observed at 81.98 and 79.10% AS for arteries with curvature angles of 0° and 120° respectively. In conclusion, the curvature of the artery should not be neglected in in vitro anatomical assessment.  相似文献   

9.
To evaluate the hemodynamic impact of coronary stenoses, the fractional (FFR) or coronary flow velocity reserve (CFVR) usually is measured. The combined measurement of instantaneous flow velocity and pressure gradient (v-dp relation) is rarely used in humans. We derived from the v-dp relation a new index, dp(v50) (pressure gradient at flow velocity of 50 cm/s), and compared the diagnostic performance of dp(v50), CFVR, and FFR. Before coronary angiography was performed, patients underwent noninvasive stress testing. In all coronary vessels with an intermediate or severe stenosis, the flow velocity, aortic, and distal coronary pressure were measured simultaneously with a Doppler and pressure guidewire after induction of hyperemia. After regression analysis of all middiastolic flow velocity and pressure gradient data, the dp(v50) was calculated. With the use of the results of noninvasive stress testing, the dp(v50) cutoff value was established at 22.4 mmHg. In 77 patients, 124 coronary vessels with a mean 39% (SD 19) diameter stenosis were analyzed. In 43 stenoses, ischemia was detected. We found a sensitivity, specificity, and accuracy of 56%, 86%, and 76% for CFVR; 77%, 99%, and 91% for FFR; and 95%, 95%, and 95% for dp(v50). To establish that dp(v50) is not dependent on maximal hyperemia, dp(v50) was recalculated after omission of the highest quartile of flow velocity data, showing a difference of 3%. We found that dp(v50) provided the highest sensitivity and accuracy compared with FFR and CFVR in the assessment of coronary stenoses. In contrast to CFVR and FFR, assessment of dp(v50) is not dependent on maximal hyperemia.  相似文献   

10.

Background

Guidewire (GW) size and stenosis dimensions are the two major factors affecting the translesional pressure drop. Studying the combined effect of these parameters on the mean pressure drop (Δp) across the stenosis is of high practical importance.

Methods

In this study, time averaged mass and momentum conservation equations are solved analytically to obtain pressure drop-flow, Δp-Q, curves for three different percentage area blockages corresponding to moderate (64%), intermediate (80%), and severe (90%) stenoses. Stenosis is considered to be axisymmetric consisting of three different sections namely converging, throat, and diverging regions. Analytical expressions for pressure drop are obtained for each of these regions separately. Using this approach, effects of lesion length and GW insertion on the mean translesional pressure drop and its component (loss due to momentum change and viscous loss) are analyzed.

Results and Conclusion

It is observed that for a given percent area stenosis (AS), increase in the throat length only increases the viscous loss. However, increase in the severity of stenosis and GW insertion increase both loss due to momentum change and viscous loss. GW insertion has greater contribution to the rise in viscous loss (increase by 2.14 and 2.72 times for 64% and 90% AS, respectively) than loss due to momentum change (1.34% increase for 64% AS and 25% decrease for 90% AS). It also alters the hyperemic pressure drop in moderate (48% increase) to intermediate (30% increase) stenoses significantly. However, in severe stenoses GW insertion has a negligible effect (0.5% increase) on hyperemic translesional pressure drop. It is also observed that pressure drop in a severe stenosis is less sensitive to lesion length variation (4% and 14% increase in Δp for without and with GW, respectively) as compared to intermediate (10% and 30% increase in Δp for without and with GW, respectively) and moderate stenoses (22% and 48% increase in Δp for without and with GW, respectively). Based on the contribution of pressure drop components to the total translesional pressure drop, it is found that viscous losses are dominant in moderate stenoses, while in severe stenoses losses due to momentum changes are significant. It is also shown that this simple analytical solution can provide valuable information regarding interpretation of coronary diagnostic parameters such as fractional flow reserve (FFR).  相似文献   

11.
Pressure-based fractional flow reserve (FFR) is used clinically to evaluate the functional severity of a coronary stenosis, by predicting relative maximal coronary flow (Q(s)/Q(n)). It is considered to be independent of hemodynamic conditions, which seems unlikely because stenosis resistance is flow dependent. Using a resistive model of an epicardial stenosis (0-80% diameter reduction) in series with the coronary microcirculation at maximal vasodilation, we evaluated FFR for changes in coronary microvascular resistance (R(cor) = 0.2-0.6 mmHg. ml(-1). min), aortic pressure (P(a) = 70-130 mmHg), and coronary outflow pressure (P(b) = 0-15 mmHg). For a given stenosis, FFR increased with decreasing P(a) or increasing R(cor). The sensitivity of FFR to these hemodynamic changes was highest for stenoses of intermediate severity. For P(b) > 0, FFR progressively exceeded Q(s)/Q(n) with increasing stenosis severity unless P(b) was included in the calculation of FFR. Although the P(b)-corrected FFR equaled Q(s)/Q(n) for a given stenosis, both parameters remained equally dependent on hemodynamic conditions, through their direct relationship to both stenosis and coronary resistance.  相似文献   

12.
A reduced coronary flow reserve (CFR) has been demonstrated in diabetes, but the underlying mechanisms are unknown. We assessed thermodilution-derived CFR after 5-min intravenous adenosine infusion through a pressure-temperature sensor-tipped wire in 30 coronary arteries without significant lumen reduction in 30 patients: 13 with and 17 without a history of diabetes. We determined CFR as the ratio of basal and hyperemic mean transit times (T(mn)); fractional flow reserve (FFR) as the ratio of distal and proximal pressures at maximal hyperemia to exclude local macrovascular disease; and an index of microvascular resistance (IMR) as the distal coronary pressure at maximal hyperemia divided by the inverse of the hyperemic T(mn). We also assessed insulin resistance by the homeostasis model assessment (HOMA) index. FFR was normal in all investigated arteries. CFR was significantly lower in diabetic vs. nondiabetic patients [median (interquartile range): 2.2 (1.4-3.2) vs. 4.1 (2.7-4.4); P = 0.02]. Basal T(mn) was lower in diabetic vs. nondiabetic subjects [median (interquartile range): 0.53 (0.25-0.71) vs. 0.64 (0.50-1.17); P = 0.04], while hyperemic T(mn) and IMR were similar. We found significant correlations at linear regression analysis between logCFR and the HOMA index (r(2) = 0.35; P = 0.0005) and between basal T(mn) and the HOMA index (r(2) = 0.44; P < 0.0001). In conclusion, compared with nondiabetic subjects, CFR is lower in patients with diabetes and epicardial coronary arteries free of severe stenosis, because of increased basal coronary flow, while hyperemic coronary flow is similar. Basal coronary flow relates to insulin resistance, suggesting a key role of cellular metabolism in the regulation of coronary blood flow.  相似文献   

13.
Abstract

To clarify the role of the guanine nucleotide binding proteins (G-proteins) in the pathogenesis of myocardial hypertrophy, we investigated the alterations in myocardial G proteins in 20-week-old F1b hamsters with pressure overload induced for 3 days (3-day AS), 7 days (7-day AS) and 14 days (14-day AS) by the stenosis of the abdominal aorta, and in 4- and 20 week-old BIO 14.6 Syrian hamsters (4-wk and 20-wk BIO) with genetic myocardial hypertrophy. The hearts of 7-day AS, 14-day AS and 20-wk BIO with left ventricular hypertrophy exhibited a decrease in the mRNA levels detected by Northem blot analysis and protein levels of G protein detected by Western blot analysis as compared with sham-operated and age-matched F1b hearts. The function of Gs or Gi showed a concomitant reduction in both models of myocardial hypertrophy. The hearts of 3-day AS and 4-wk BIO without myocardial hypertrophy showed no changes in G proteins as compared with sham-operated and age-matched F1b hearts. These results suggest that a decrease in G proteins is not involved in the pathogenesis of myocardial hypertrophy, but that myocardial hypertrophy reduced the G proteins.  相似文献   

14.
Deficiency of β-glucuronidase is the cause of the human lysosomal storage disorder mucopolysaccharidosis type VII (MPS VII). The wide interfamilial variation in the presentation of this disorder complicates clinical diagnosis. Since greatly reduced β-glucuronidase enzyme activity may also be found in healthy individuals (pseudodeficiency), diagnosis based on the biochemical phenotype is also difficult. This is illustrated by the patients studied here, who had extremely mild symptoms confined to the spine, or tachycardia, or upper respiratory infection, and who had low β-glucuronidase activity, and excessive granulation of granulocytes and monocytes on routine blood smears. Low enzyme activity was caused by mutations in the β-glucuronidase gene in all cases. One patient was homozygous for the previously described D152N allele. Family information and 35SO4-uptake studies clearly demonstrated that he was pseudodeficient, with symptoms unrelated to his low β-glucuronidase activity. Two patients of another family were compound heterozygotes for a C38G and a Y626H allele, and were probably extremely mild MPS VII patients. The low β-glucuronidase activity in another mild MPS VII patient was due to reduced biosynthesis of stable mRNA from one allele, and a W446X mutation on the second. Extremely low β-glucuronidase enzyme activity was also found in the serum of a carrier of a 1801ΔT allele, possibly as a consequence of a dominant-negative effect. A combination of investigations is necessary in order to differentiate between mild disease and pseudodeficiency in individuals with enzyme activities close to the threshold. Received: 31 May 1997 / Accepted: 26 Augsut 1997  相似文献   

15.
16.
目的:比较冠状动脉CT血管成像(CT angiography,CTA)以及数字减影血管造影(digital subtraction angiography,DSA)诊断冠心病的临床价值差异。方法:选择2013年12月至2020年3月安徽医科大学第三附属医院、安徽医科大学第四附属医院收治的60例冠心病患者为研究对象,首先对其实施多排螺旋CT冠状动脉血管造影检测(CTA),而后2 w内再对其实施DSA检测,比较两种检测方式对不同血管狭窄程度、不同性质斑块检出率的差异,最后以DSA检测结果为金标准,评估CTA对冠状动脉狭窄诊断的一致性、灵敏度、特异度、阳性预测值和阴性预测值。结果:(1)CTA检测狭窄血管共计387支,轻度狭窄152支(39.28%),中度狭窄118支(30.49%),重度狭窄105支(27.13%),闭塞12支(3.10%);DSA检测狭窄血管392支,轻度狭窄150支(38.27%),中度狭窄124支(31.63%),重度狭窄112支(28.57%),闭塞6支(1.53%),两组各血管狭窄类型比较差异无统计学意义(P0.05);(2)CTA检测斑块69个,其中钙化斑43个(62.32%),非钙化斑26个(37.68%),DSA检测斑块61个,其中钙化斑33个(54.10%),非钙化斑28个(45.50%),两种检测方式差异无统计学意义(P0.05);(3)以DSA检测为金标准,CTA对重度及以上血管狭窄诊断一致性为99.23%,特异度为98.31%,灵敏度为99.64%,阳性预测值为99.15%,阴性预测值为99.27%。结论:与DSA相比,CTA对冠心病患者血管狭窄的诊断价值相当,且属于无创检测,在冠心病早期筛查中临床应用价值更高。  相似文献   

17.
Coronary computed tomography angiography (CCTA) in combination with first-pass CT myocardial perfusion imaging (MPI) has a better diagnostic performance than CCTA alone, compared with invasive coronary angiography as the reference standard. The aim of this study was to investigate the additional diagnostic value of first-pass CT-MPI without stress for detecting hemodynamic significance of coronary stenosis, compared with invasive fractional flow reserve (FFR). We recruited 53 patients with suspected coronary artery disease undergoing both CCTA and first-pass CT-MPI without stress and invasive FFR, and 75 vessels were analyzed. We used the same raw data for CCTA and CT-MPI. First-pass CT-MPI was reconstructed by examining the diastolic signal densities as a bull’s eye map. Invasive FFR <0.8 was considered as positive. On per-vessel analysis, the area under the receiver operating characteristic curve for CCTA plus first-pass CT-MPI and CCTA alone was 0.81 (0.73–0.90) and 0.70 (0.61–0.81), respectively (P = 0.036). CCTA plus first-pass CT-MPI without stress showed 0.73 sensitivity, 0.74 specificity, 0.53 positive predictive value, and 0.87 negative predictive value for detecting hemodynamically significant coronary stenosis. First-pass CT-MPI without stress correctly reclassified 38% of CCTA false-positive vessels as true negative. First-pass CT-MPI without stress combined with CCTA demonstrated excellent diagnostic accuracy, compared with invasive FFR as the reference standard. This technique could complement CCTA for diagnosis of coronary artery disease.  相似文献   

18.
目的:探讨超声二维斑点追踪成像技术(2DSTI)评价主动脉瓣狭窄(AS)患者左室功能早期改变的临床价值。方法:选取我院自2012年4月至2012年12月左室射血分数(LVEF)正常的AS(中-重度)患者30例(AS组),正常对照组30例。获取心尖位左室长轴观、二腔观和四腔观各节段收缩期纵向峰值应变(SL),并计算左室基底段、中间段、心尖段SL平均值及左室整体纵向应变值(GLS)。结果:AS组与对照组的左室射血分数差异无统计学意义(P0.05),AS组与对照组的主动脉瓣瓣口面积及平均压差具有统计学意义(P0.05);AS组患者整体、基底段、中间段、心尖段的GLS均低于对照组(P0.05)。结论:超声二维斑点追踪成像技术能够评价主动脉瓣狭窄左室心肌收缩功能的早期异常改变。  相似文献   

19.
Clinical studies reported that some vulnerable stenoses deformed their shape in a blood vessel based on flow condition. However, the effects of shape variation on flow characteristics remain unclear. The flow characteristics are known to affect vulnerable stenosis rupture and fractional flow reserve (FFR) value which has been widely used as a diagnostic tool for stenosis. Vulnerable stenosis rupture occurs when the structural stress exerted on a fibrous cap exceeds its tolerable threshold. The stress magnitude is determined from the spatial distribution of static pressure around the stenosis. In the present study, the static pressure distribution and the FFR value in deformable stenosis were investigated with related other flow characteristics. Two phantom models were fabricated to mimic deformable and nondeformable stenoses using polydimethylsiloxane. The flow characteristics were observed under a steady-flow condition at three Reynolds numbers (Re = 500, 1000, 1500) using a particle image velocimetry. The pressure drop across the stenosis models were measured using a pressure sensor to determine effects of shape deformation on FFR value. Shape variations and jet deflections were clearly observed in the deformable stenosis model, and the effective severity of the stenosis increased up to 17.2%. The shape variations of deformable stenosis model increased the static pressure difference at the upstream and downstream sides of the stenosis. The pressure drop across the deformable stenosis model was significantly higher than that of the nondeformable stenosis model. The present results substantiate that stenosis deformability should be carefully considered to diagnose the rupture of vulnerable stenosis.  相似文献   

20.
 In the present study three novel genes from barley accessions 10247 (ym8), Bulgarian 347 (ym9), and Russia 57 (ym11), which confer resistance to Barley Mild Mosaic Virus (BaMMV), were mapped using molecular markers. Bulked segregant analysis of four progenies segregating for resistance to BaMMV was followed by fine-scale mapping of the resistance genes using individual F2 or BC1F2 plants. The resistance genes are inherited recessively and are located on the long arm of barley chromosome 4HL. A series of closely linked molecular markers are available for marker-assisted breeding programs. A marker (MWG2134) linked with resistance gene ym11 from Russia 57 was identified, which is diagnostic for the resistance gene. Received: 25 July 1997 / Accepted: 22 August 1997  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号