The major pectenotoxin and okadaic acid group toxins in Dinophysis acuta and Dinophysis acuminata cell concentrates, collected from various locations around the coast of the South Island of New Zealand (NZ), were determined by liquid chromatography–tandem mass spectrometry (LC–MS/MS). PTX2 and PTX11 were the major polyether toxins in all Dinophysis spp. cell concentrates. D. acuta contained PTX11 and PTX2 at concentrations of 4.7–64.6 and 32.5–107.5 pg per cell, respectively. The amounts of PTX11 and PTX2 in D. acuminata were much lower at 0.4–2.1 and 2.4–25.8 pg per cell, respectively. PTX seco acids comprised only 4% of the total PTX content of both D. acuta and D. acuminata. D. acuta contained low levels of OA (0.8–2.7 pg per cell) but specimens from the South Island west coast also contained up to 10 times higher levels of OA esters (7.0–10.2 pg per cell). Esterified forms of OA were not observed in D. acuta specimens from the Marlborough Sounds. D. acuta did not contain any DTX1 though all D. acuminata specimens contained DTX1 at levels of 0.1–2.4 pg per cell. DTX2 was not present in any New Zealand Dinophysis spp. specimens. Although the total toxin content varied spatially and temporally, the relative proportions of the various toxins in different specimens from the same location appeared to be relatively stable. The total PTX/total OA ratios in different isolates of D. acuta were very similar (mean±S.E.: 14.9±1.9), although the Marlborough Sounds D. acuminata isolates had a higher total PTX/total OA ratio (mean±S.E.: 22.7±2.4) than the Akaroa Harbour isolates (8.0). No evidence of azaspiracids were detected in these specimens. These results show that the LC–MS/MS monitoring of plankton for PTX group toxins (e.g. PTX2) and their derivatives (e.g. PTX2 seco acid) may provide a sensitive, semi-quantitative, indicator of the presence of more cryptic OA group toxins (e.g. OA esters).  相似文献   

2.
A sensitive, specific, accurate and reproducible LC–MS–MS method was developed and validated for the simultaneous quantitation of the prodrug fosinopril and its active drug fosinoprilat in human serum. The method employed acidification of the serum samples to minimize the hydrolysis of fosinopril to fosinoprilat prior to purification by solid-phase extraction to isolate the two analytes and the two internal standards from human serum. The extracted samples were analyzed by turbo ionspray LC–MS–MS in the positive ion mode. Chromatography was performed on a polymer-based C18 column (Asahipak™ ODP PVA-C18, 2×50 mm) using gradient elution with methanol and 10 mM ammonium acetate, pH 5.5. The calibration curve, 1.17 to 300 ng/ml, was fitted to a weighted (l/x) linear regression model. Serum quality control (QC) samples used to gauge the accuracy and precision of the method were prepared at concentrations of 5.00, 100, 250 and 500 ng/ml of each analyte. The inter-assay accuracies were within 6% (DEV) for both analytes. The intra- and inter-assay precisions were within 7% and 11% (RSD), respectively, for both analytes. The hydrolysis of fosinopril to fosinoprilat during sample processing was ≤6%. This degree of conversion would cause little error in the analysis of post-dose serum samples since such samples are known to contain low levels of the prodrug compared to the drug.  相似文献   

3.
For the first time, an LC–MS–MS method has been developed for the simultaneous analysis of buprenorphine (BUP), norbuprenorphine (NBUP), and buprenorphine–glucuronide (BUPG) in plasma. Analytes were isolated from plasma by C18 SPE and separated by gradient RP-LC. Electrospray ionization and MS–MS analyses were carried out using a PE-Sciex API-3000 tandem mass spectrometer. The m/z 644→m/z 468 transition was monitored for BUPG, whereas for BUP, BUP-d4, NBUP, and NBUP-d3 it was necessary to monitor the surviving parent ions in order to achieve the required sensitivity. The method exhibited good linearity from 0.1 to 50 ng/ml (r2≥0.998). Extraction recovery was higher than 77% for BUPG and higher than 88% for both BUP and NBUP. The LOQ was established at 0.1 ng/ml for the three analytes. The method was validated on plasma samples collected in a controlled intravenous and sublingual buprenorphine administration study. Norbuprenorphine–glucuronide was also tentatively detected in plasma by monitoring the m/z 590→m/z 414 transition.  相似文献   

4.
A sensitive and specific assay has been developed for measurement of total sulfidopeptide leukotriense (LT) in plasma. LTC4 and LTD4 in plasma are converted to LTE4 which is then extracted by C18 Sep-Pak binding and elution. Total LTE4 in resolved by reverse phase high performance liquid chromatography (RP-HPLC) and quantitated by radioimmunoassay (RIA). A [3H]LTE4 internal standard is added to the starting plasma sample to allow RP-HPLC to be assayed for LTE4-like immunoreactivity. The correlation between the measured increase in LTE4 concentration after addition of incremental amounts of LTC4 and LTE4 to plasma was 0.989 and 0.978, respectively, with slopes of 1.05 and 1.11. Addition of 51 pg/ml LTE4 to 5 ml plasma was detectable; the measured increase was 48 ± 12 pg/ml (mean ± SE, n = 7). The intra-assay coefficient of variation for 341 pg/ml of added LTC4 was 3.2% (n = 6). Sulfidopeptide leukotrienes could not be detected in blood samples taken from 12 normal volunteers in whom the theoretical detection limit, calculated from the sensitivity of the RIA, the overall recovery of LTE4, and the volume of plasma extracted, was 83 ± 4 pg LTE4/ml plasma (0.19 ± 0.01 pmol sulfidopeptide leukotriene/ml plasma; mean ± SE).  相似文献   

5.
A sensitive, selective, and reproducible GC–MS–SIM method was developed for determination of artemether (ARM) and dihydroartemisinin (DHA) in plasma using artemisinin (ART) as internal standard. Solid phase extraction was performed using C18 Bond Elut cartridges. The analysis was carried out using a HP-5MS 5% phenylmethylsiloxane capillary column. The recoveries of ARM, DHA and ART were 94.9±1.6%, 92.2±4.1% and 81.3±1.2%, respectively. The limit of quantification in plasma was 5 ng/ml (C.V.≤17.4% for ARM and 15.2% for DHA). Calibration curves were linear with R2≥0.988. Within day coefficients of variation were 3–10.4% for ARM and 7.7–14.5% for DHA. Between day coefficients of variations were 6.5–15.4% and 7.6–14.1% for ARM and DHA. The method is currently being used for pharmacokinetic studies. Preliminary data on pharmacokinetics showed Cmax of 245.2 and 35.6 ng/ml reached at 2 and 3 h and AUC0–8h of 2463.6 and 111.8 ngh/ml for ARM and DHA, respectively.  相似文献   

6.
Resident mouse peritoneal cells, stimulated with opsonized zymosan, produced leukotriene C4 and E4, with LTE4 being the major (80–90%) product. When mice were placed on diets containing increasing amounts of fish oil, four additional sulfidopeptide leukotrienes (SP-LT), LTC5, LTE5, 11-trans LTC5 and 11-trans LTE5, were identified. The identity of LTE5 was confirmed by spectrophotometric, chromatographic and enzymatic methods. When equivalent amounts of n-6 and n-3 polyunsaturated fatty acids (PUFA) were included in the diet, the stimulated peritoneal cells ( ) produced higher quantities of LTE5 (30.2 ± 5.4 ng/106 cells) than LTE4 (22.8 ± 7.3 ng/106 cells). In addition, studies demonstrated a 60% reduction in LTC4 (42.0 ± 10.8 ng/106 cells to 16.7 ± 6.2 ng/106 cells) and the appearance of LTC5 (2.1 ± 0.9 ng/106 cells) in resident macrophages (stimulated with A23187) from mice maintained on a fish oil diet compared to mice fed the control diet. This study demonstrated that formation of the pentaenyl SP-LT , in particular LTE5, by peritoneal cells can significantly contribute to the endogenous SP-LT pool in response to an inflammatory stimulus following a dietary regimen containing fish oil.  相似文献   

7.
We report here the development and validation of an LC–MS method for quantitation of loperamide (LOP) and its N-demethyl metabolite (DMLOP) in human plasma. O-Acetyl-loperamide (A-LOP) was synthesized by us for use as an internal standard in the assay. After addition of the internal standard, the compounds of interest were extracted with methyl tert.-butylether and separated by HPLC on a C18 reversed-phase column using an acetonitrile–water gradient containing 20 mM ammonium acetate. The three compounds were well separated by HPLC and no interfering peaks were detected at the usual concentrations found in plasma. Analytes were quantitated using positive electrospray ionization in a triple quadrupole mass spectrometer operating in the MS–MS mode. Selected reaction monitoring was used to quantify LOP (m/z 477→266), DMLOP (m/z 463→252) and A-LOP (m/z 519→266) on ions formed by loss of the 4-(p-chlorophenyl)-4-hydroxy-piperidyl group upon low energy collision-induced dissociation. Calibration curves, which were linear over the range 1.04 to 41.7 pmol/ml (LOP) and 1.55 to 41.9 pmol/ml (DMLOP), were run contemporaneously with each batch of samples, along with low (4.2 pmol/ml), medium (16.7 pmol/ml) and high (33.4 pmol/ml) quality control samples. The lower limit of quantitation (LLQ) of LOP and DMLOP was about 0.25 pmol/ml in plasma. The extraction efficiency of LOP and DMLOP from human plasma was 72.3±1.50% (range: 70.7–73.7%) and 79.4±12.8% (64.9–88.8%), respectively. The intra- and inter-assay variability of LOP and DMLOP ranged from 2.1 to 14.5% for the low, medium and high quality control samples. The method has been used successfully to study loperamide pharmacokinetics in adult humans.  相似文献   

8.
Employing high-performance liquid chromatography–electrospray mass spectrometry, we describe a new assay for monitoring 3-hydroxy-3-methylglutaryl-coenzyme A (HMG-CoA) reductase activity. Incubations were carried out with HMG-CoA reductase (rat liver), HMG-CoA and NADPH, and terminated by the addition of HCl. The reaction product, mevalonolactone, and internal standard, were extracted with ethyl acetate, dissolved in methanol, and analyzed by LC–MS. Using an isocratic mobile phase of 10% acetonitrile and 0.1% formic acid (flow-rate, 0.2 ml/min), the protonated molecules of mevalonolactone at m/z 131 and internal standard, β,β-dimethyl-γ-(hydroxymethyl)-γ-butyrolactone, at m/z 145, were detected using selected ion monitoring. The limit of detection was approximately 6.5 pg, and the limit of quantitation was approximately 16.3 pg. Extraction recovery was >90%. The relative standard deviations for intra- and inter-day assays were approximately 4.1±2.7 and 9.4±3.4%, respectively. Mevalonolactone was examined over a period of 3 days and found to be stable. Using this assay, lovastatin and mevastatin inhibited HMG-CoA reductase activity with IC50 values 0.24±0.02 and 2.16±0.31 μM, respectively. These methods offer some advantages over those reported previously which employ radiolabeled substrate and products, and should be useful in searching for compounds that could lower serum cholesterol or alter cell growth and differentiation.  相似文献   

9.
A fast, robust and sensitive LC–MS–MS method for the determination of zearalenone (ZON) and its metabolites α-zearalenol (α-ZOL) and β-zearalenol (β-ZOL) in beer samples is described. Sample preparation was performed by direct RP-18 solid-phase extraction of undiluted beer samples followed by selective determination of analytes by LC–MS–MS applying an atmospheric pressure chemical ionization (APCI) interface. Using the negative ion mode limits of determination of 0.03–0.06 μg l−1 beer and limits of quantification of 0.07–0.15 μg l−1 beer were achieved, which was distinctly more sensitive than in the positive ion mode. Twenty-three beer samples from different countries, produced from different grains and under different brewing conditions, were investigated by this method, but only in one sample could β-ZOL and ZON be detected. Independently of the type of beer, relative standard deviations between 2.1% and 3.3%, a linear working range of 0.15 μg l−1 to 500 μg l−1 beer and recovery rates around 100% could be achieved when zearalanone (ZAN) was used as internal standard.  相似文献   

10.
Pulmonary responses to intravenous leukotrienes C4, D4 and E4 administered as a bolus injection and by continuous infusion were studied in anesthetized guinea pigs. LTD4, LTC4 and LTE4 (respective ED50 of 0.21 ± .1, 0.64 ± .2 and 2.0 ± .1 μg kg−1) produced dose-dependent increases in insufflation pressure when given as a bolus injection to anesthetized guinea pigs (Konzett-Rössler). Bronchoconstriction was antagonized by FPL-55712 (50–200 μg kg−1), and indomethacin (50–200 μg kg−1) but was not significantly altered by mepyramine (1.0 mg kg−1), methysergide (0.1 mg kg−1), intal (10 mg kg−1) mepacrine (5 mg kg−1) or dexamethasone (10 mg kg−1). The beta adrenoceptor blocker, timolol (5 μg kg−1) produced a significantly greater potentiation of the responses to the leukotrienes than to arachidonic acid, histamine and acetylcholine. Responses to bolus injection of LTE4 but not LTD4 or LTC4 were partially antagonized by atropine (100 μg kg−1) and bilateral vagotomy. In experiments of a different design, continuous infusion of LTD4 and LTE4 (2.8–3.2 μg kg−1 min−1) into indomethacin-treated animals produced slowly developing increases in pulmonary resistance and decreases in compliance. The increase in resistance produced by LTE4 and LTD4 was partly reversed by intravenous FPL-55712 (1.0 mg kg−1) and atropine (100 μg kg−1) but was almost completely reversed by FPL-55712 (3 – 10 mg kg−1). These findings indicate that leukotrienes can produce bronchoconstriction in guinea pigs through cyclooxygenase-dependent and cyclooxygenase independent mechanisms both of which are blocked by FPL-55712. Cholinergic mechanisms are involved in the mediation of part of the response to bolus injection of LTE4 as well as a small part of the initial response to continuous infusion of LTD4 and LTE4. Intrinsic beta adrenoceptor activation serves to down modulate responses to the leukotrienes to a greater extent than responses to arachidonic acid, histamine and acetylcholine.  相似文献   

11.
Morphine (MOR) is an opioid analgesic used for the treatment of moderate to severe pain. MOR is extensively metabolized to morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G). A rapid and sensitive method that was able to reliably detect at least 0.5 ng/ml of MOR and 1.0 ng/ml of M6G was required to define their pharmacokinetic profiles. An LC–MS–MS method was developed in our laboratory to quantify all three analytes with the required sensitivity and a rapid turnaround time. A solid-phase extraction (SPE) was used to isolate MOR, M3G, M6G, and their corresponding deuterated internal standards from heparinized plasma. The extract was injected on a LC tandem mass spectrometer with a turbo ion-spray interface. Baseline chromatographic separation among MOR, M3G, and M6G peaks was achieved on a silica column with an aqueous organic mobile phase consisting of formic acid, water, and acetonitrile. The total chromatographic run time was 3 min per injection, with retention times of 1.5, 1.9 and 2.4 min for MOR, M6G, and M3G, respectively. Chromatographic separation of M3G and M6G from MOR was paramount in establishing the LC–MS–MS method selectivity because of fragmentation of M3G and M6G to MOR at the LC–MS interface. The standard curve range in plasma was 0.5–50 ng/ml for MOR, 1.0–100 ng/ml for M6G, and 10–1000 ng/ml for M3G. The inter-day precision and accuracy of the quality control (QC) samples were <7% relative standard deviation (RSD) and <6% relative error (R.E.) for MOR, <9% RSD and <5% R.E. for M6G, and <3% RSD and <6% R.E. for M3G. Analyte stability during sample processing and storage were established. Method ruggedness was demonstrated by the reproducible performance from multiple analysts using several LC–MS–MS systems to analyze over one thousand samples from clinical trials.  相似文献   

12.
A highly efficient direct injection/on-line guard cartridge extraction–tandem mass spectrometry (DI/GCE–MS–MS) method has been validated for high-throughput evaluation of cytochrome P450 (CYP) 2D6 inhibition potential using human hepatic microsomes and 96-well microtiter plates. Microsomal incubations were terminated with formic acid, centrifuged, and the resulting supernatants were injected for DI/GCE–MS–MS analysis. Due to the novel use of an extremely short C18 guard cartridge, this method exhibits several advantages, such as no sample preparation, excellent on-line extraction, short run time (2.5 min), and minimized source contamination and performance deterioration. The DI/GCE–MS–MS method demonstrates acceptable accuracy and precision for the quantification of dextrorphan, a marker metabolite of dextromethorphan mediated by CYP2D6, in microsomal incubations. The CYP2D6 inhibition assay has been validated using quinidine as a known selective inhibitor of the isoform. The IC50 value (0.20 μM) measured by the new method is in good agreement with the literature value (0.22 μM).  相似文献   

13.
A liquid chromatography–electrospray ionization tandem mass spectrometric method was developed for the simultaneous determination of losartan and its major active metabolite, EXP-3174, in human plasma. The two analytes and the internal standard (DuP-167) were extracted from plasma under acidic conditions by using solid-phase extraction cartridges containing a sorbent of copolymer, poly(divinylbenzene-co-N-vinylpyrrolidone). The analytes were separated by LC equipped with a reversed-phase C18 column, and introduced into the mass spectrometer via the electrospray ion source with pneumatically-assisted nebulization. For LC–MS–MS samples, an isocratic mobile phase consisting of [0.1% triethylamine–0.1% acetic acid (pH 7.1)]–acetonitorile (65:35, v/v) was used, and the assay was monitored for the negative fragment ions of the analytes. The method demonstrated linearity from 1 to 1000 ng/ml for both losartan and EXP-3174. The limit of quantification for both compounds in plasma was 1 ng/ml. This assay method may be useful for the measurement of levels of the two compounds in clinical studies of losartan.  相似文献   

14.
A sensitive and specific analytical method for a potent antitumor agent, TZT-1027, in plasma has been developed using liquid chromatography–mass spectrometry (LC–MS) with [2H4]TZT-1027 as an internal standard (I.S.). A plasma sample was purified by solid-phase extraction on a C18 cartridge, followed by solvent extraction with diethyl ether. The extract was then injected into the LC–MS system. Chromatography was carried out on a C18 reversed-phase column using acetonitrile–0.05% trifluoroacetic acid (TFA) (55:45) as a mobile phase. Mass spectrometric analysis was performed in atmospheric pressure chemical ionization (APCI) mode with positive ion detection, and the protonated molecular ions ([M+H]+) of TZT-1027 and I.S. were monitored to allow quantitation. The method was applied to the determination of TZT-1027 in human, monkey, dog, rat and mouse plasma. As far as the sample preparation was concerned, good recoveries (73.5–99.1%) were obtained. The calibration curves were linear over the range of 0.25–100 ng per 1 ml of human, dog and rat plasma, per 0.5 ml of monkey plasma, and per 0.1 ml of mouse plasma. From the intra- and inter-day accuracy and precision, the present method satisfies the accepted criteria for bioanalytical method validation. TZT-1027 was stable when stored below −15°C for 6 months in human plasma and for 3 weeks in plasma from other species. TZT-1027 was also stable in plasma through at least three freeze–thaw cycles.  相似文献   

15.
A rapid and sensitive high-performance liquid chromatography–electrospray MS method has been developed to determine tissue distribution of betulinic acid in mice. The method involved deproteinization of these samples with 2.5 volumes (v/w) of acetonitrile–ethanol (1:1) and then 5 μl aliquots of the supernatant were injected onto a C18 reversed-phase column coupled with an electrospray MS system. The mobile phase employed isocratic elution with 80% acetonitrile for 10 min; the flow-rate was 0.7 ml/min. The column effluent was analyzed by selected ion monitoring for the negative pseudo-molecular ion of betulinic acid [M−H] at m/z 455. The limit of detection for betulinic acid in biological samples by this method was approximately 1.4 pg and the coefficients of variation of the assay (intra- and inter-day) were generally low (below 9.1%). When athymic mice bearing human melanoma were treated with betulinic acid (500 mg/kg, i.p.), distribution was as follows: tumor, 452.2±261.2 μg/g; liver, 233.9±80.3 μg/g; lung, 74.8±63.7 μg/g; kidney, 95.8±122.8 μg/g; blood, 1.8±0.5 μg/ml. No interference was noted due to endogenous substances. These methods of analysis should be of value in future studies related to the development and characterization of betulinic acid.  相似文献   

16.
A sensitive and specific assay of human plasma for the determination of (5α,7β,16β)-16[(4-chlorophenyl)oxy]-4,7-dimethyl-4-aza-andronstan-3-one (I), a selective inhibitor of human type 1 5α-reductase, has been developed. The method is based on high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS–MS) detection. The analyte (I) and internal standard, Proscar (II), were isolated from the basified biological matrix using a liquid–liquid extraction with methyl-tert.-butyl ether (MTBE). The organic extract was evaporated to dryness, the residue was reconstituted in mobile phase and injected into the HPLC system. The MS–MS detection was performed on a PE Sciex API III Plus tandem mass spectrometer using a heated nebulizer interface. Multiple reaction monitoring using the precursor→product ion combinations of m/z 430→114 and 373→305 was used to quantify I and internal standard (II), respectively. The assay was validated in the concentration range of 0.5 to 500 ng/ml in human plasma. The precision of the assay, expressed as coefficient of variation (C.V.), was less than 7% over the entire concentration range, with adequate assay specificity and accuracy. The HPLC–MS–MS method provided sufficient sensitivity to completely map the 24 h pharmacokinetic time-course following a single 0.5 mg dose of I.  相似文献   

17.
A column-switching liquid chromatography–electrospray ionization-tandem mass spectrometric (LC–ESI-MS–MS) method was developed for the direct analysis of entacapone glucuronide in plasma. The plasma samples (5 μl) were injected onto a C18-alkyl-diol silica (ADS) column and the matrix compounds were washed to waste with a mixture of 20 mM ammonium acetate solution at pH 4.0–acetonitrile (97:3). The retained analyte fraction containing (E)- and (Z)-isomers of glucuronides of entacapone and tolcapone glucuronide (internal standard) was backflushed to the analytical C18 column, with a mixture of 20 mM ammonium acetate–acetonitrile (85:15) for the final separation at pH 7.0. The eluate was directed to the mass spectrometer after splitting (1:100). The mass spectrometer was operated in the negative ion mode and the deprotonated molecules [M−H] were chosen as precursor ions for the analytes and internal standard. Collisionally induced dissociation of [M−H] in MS–MS resulted in loss of the neutral glucuronide moiety and in the appearance of intensive negatively charged aglycones [M−H−Glu], which were chosen as the product ions for single reaction monitoring. Quantitative studies showed a wide dynamic range (0.0025–100 μg/ml) with correlation coefficients better than 0.995. The method was repeatable within-day (relative standard deviation, RSD<7%) and between-day (RSD<14%) and the recovery (78–103%) was better than with the traditional, laborious pretreatment method. The use of tandem mass spectrometry permitted low limits of detection (1 ng/ml of entacapone glucuronide). The method was applied for the quantitation of (E)- and (Z)-isomers of entacapone glucuronide in plasma of rats used in absorption studies.  相似文献   

18.
A selected-ion monitoring (SIM) determination of serum lycopene, α-carotene and β-carotene by an atmospheric pressure chemical ionization mass spectrometry (APCI–MS) was developed. A large amount of serum cholesterols disturbed the SIM determination of carotenoids by contaminating the segment of interface with the LC–MS. Therefore, separation of carotenoids from the cholesterols was performed using a mixed solution of methanol and acetonitrile (70:30) as the mobile phase on a C18 column of mightsil ODS-5 (75 mm×4.6 mm I.D.). The SIM determination was carried out by introducing only the peak portions of carotenoids and I.S. (squalene) by means of an auto switching valve. In the positive mode of APCI–MS, lycopene, α-carotene and β-carotene were monitored at m/z 537 and I.S. was monitored at m/z 411. This method was linear for all analytes in the range of 15–150 ng for lycopene, 7–70 ng for α-carotene and 25–50 ng for β-carotene. The detection limit of LC–APCI–MS-SIM for carotenoids was about 3 ng per 1 ml of serum (S/N=3). The repeatabilities, expressed as C.V.s, were 10%, 8.4% and 5.3% for lycopene, α-carotene and β-carotene, respectively. The intermediate precisions, expressed as C.V.s, were 11. 2%, 8.8% and 6.5% for lycopene, α-carotene and β-carotene, respectively.  相似文献   

19.
A sensitive and selective reversed-phase LC–ESI-MS method to quantitate perifosine in human plasma was developed and validated. Sample preparation utilized simple acetonitrile precipitation without an evaporation step. With a Develosil UG-30 column (10×4 mm I.D.), perifosine and the internal standard hexadecylphosphocholine were baseline separated at retention times of 2.2 and 1.1 min, respectively. The mobile phase consisted of eluent A, 95% 9 mM ammonium formate (pH 8) in acetonitrile–eluent B, 95% acetonitrile in 9 mM ammonium formate (pH 8) (A–B, 40:60, v/v), and the flow-rate was 0.5 ml/min. The detection utilized selected ion monitoring in the positive-mode at m/z 462.4 and 408.4 for the protonated molecular ions of perifosine and the internal standard, respectively. The lower limit of quantitation of perifosine was 4 ng/ml in human plasma, and good linearity was observed in the 4–2000 ng/ml range fitted by linear regression with 1/x weight. The total LC–MS run time was 5 min. The validated LC–MS assay was applied to measure perifosine plasma concentrations from patients enrolled on a phase I clinical trial for pharmacokinetic/pharmacodynamic analyses.  相似文献   

20.
This work presents the development and the validation of an LC–MS–MS method with atmospheric pressure chemical ionization for the quantitative determination of levamisole, an anthelmintic for veterinary use, in porcine tissue samples. A liquid–liquid back extraction procedure using hexane–isoamylalcohol (95:5, v/v) as extraction solvent was followed by a solid-phase extraction procedure using an SCX column to clean up the tissue samples. Methyllevamisole was used as the internal standard. Chromatographic separation was achieved on a LiChrospher® 60 RP-select B (5 μm) column using a mixture of 0.1 M ammonium acetate in water and acetonitrile as the mobile phase. The mass spectrometer was operated in MS–MS full scanning mode. The method was validated for the analysis of various porcine tissues: muscle, kidney, liver, fat and skin plus fat, according to the requirements defined by the European Community. Calibration graphs were prepared for all tissues and good linearity was achieved over the concentration ranges tested (r>0.99 and goodness of fit <10%). Limits of quantification of 5.0 ng/g were obtained for the analysis of levamisole in muscle, kidney, fat and skin plus fat tissues, and of 50.0 ng/g for liver analysis, which correspond in all cases to half the MRLs (maximum residue limits). Limits of detection ranged between 2 and 4 ng/g tissue. The within-day and between-day precisions (RSD, %) and the results for accuracy fell within the ranges specified. The method has been successfully used for the quantitative determination of levamisole in tissue samples from pigs medicated via drinking water. Moreover the product ion spectra of the levamisole peak in spiked and incurred tissue samples were in close agreement (based on ion ratio measurements) with those of standard solutions, indicating the worthiness of the described method for pure qualitative purposes.  相似文献   