首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The possibility of detection of serological markers, containing the hepatitis B surface antigen (HBsAg) and hepatitis C virus core-antigen (HCVcoreAg) in human serum, by a new atomic force microscopy (AFM)-based nanotechnological approach has been demonstrated. The antibodies against the hepatitis B virus surface antigen (anti-HBsAg) and the antibodies against the hepatitis C virus core antigen (anti-HCVcoreAg) were immobilized on an AFM-chip. It was shown that such approach enables to detect HBsAg, HCVcoreAg and the viral fragments containing these antigens in the serum. The comparative analysis of detection of HBsAg- and HCVcoreAg-containing particles by the AFM method versus traditional methods (ELISA, PCR) has demonstrated the 75% coincidence of results between the AFM and two other methods.  相似文献   

2.
Zhang X  Shi L  Shu S  Wang Y  Zhao K  Xu N  Liu S  Roepstorff P 《Proteomics》2007,7(14):2340-2349
An improved method for sample preparation for MALDI-MS and MS/MS using AnchorChip targets is presented. The method, termed the SMW method (sample, matrix wash), results in better sensitivity for peptide mass fingerprinting as well as for sequencing by MS/MS than previously published methods. The method allows up-concentration and desalting directly on the mass spectrometric target and should be amenable for automation. A draw back caused by extensive oxidation of methionine and tryptophan in the SMW method can be alleviated by the addition of n-octyl glucopyranoside and DTT to the sample solution. The method was validated for protein identification from a 2-DE based liver proteome study. The SMW method resulted in identification of many more proteins and in most cases with a better score than the previously published methods.  相似文献   

3.
A method of atomic force microscopy-based fishing (AFM fishing) has been developed for protein detection in the analyte solution using a chip with an immobilized aptamer. This method is based on the biospecific fishing of a target protein from a bulk solution onto the small AFM chip area with the immobilized aptamer to this protein used as the molecular probe. Such aptamer-based approach allows to increase an AFM image contrast compared to the antibody-based approach. Mass spectrometry analysis used after the biospecific fishing to identify the target protein on the AFM chip has proved complex formation. Use of the AFM chip with the immobilized aptamer avoids interference of the antibody and target protein peaks in a mass spectrum.  相似文献   

4.
MALDI-TOF质谱技术对克罗诺杆菌的鉴定与分型   总被引:3,自引:1,他引:2  
以基质辅助激光解析电离飞行时间质谱(MALDI-TOFMS)技术用于克罗诺杆菌的鉴定与分型。通过对获得的克罗诺杆菌属典型菌株、阴沟肠杆菌和产气肠杆菌近似菌株以及克罗诺杆菌分离株的蛋白质质量图谱进行对比分析,找出克罗诺杆菌特征性离子峰,将其作为鉴定克罗诺杆菌的生物标识物;对全细菌蛋白质质量图谱进行聚类分析,将克罗诺杆菌属进一步划分为不同类型,结果显示,4株克罗诺杆菌参考菌株质量图谱约在5740(m/z)离子质荷比处出现1个相近离子峰,28株克罗诺杆菌分离株中27株(占96.4%)表现出相同结果;32株克罗诺杆菌被分为6种类型(以50%距离水平为分类界限)。MALDI-TOFMS作为一种新的技术,不仅能够用于克罗诺杆菌的鉴定,而且根据获得的细菌蛋白质质量图谱可将克罗诺杆菌划分为不同类型。  相似文献   

5.
6.
Ginkgo biloba is one of the most popular herb nutrition supplements, with terpene lactones and flavonoids being the two major active components. A fingerprint profile method was developed using a capillary HPLC/MS method which can identify more than 70 components from the G. biloba product. The method allows the flavonoids and terpene lactones to be detected simultaneously and information of both the parent ion and its fragmentation can be obtained in just one HPLC/MS run. Targeted post-acquisition analysis allows mass spectrometric information regarding the identification of flavonoid components to be easily distinguished from other data, however the same approach for terpene lactones was less successful due to dimer formation and requires further development. The fingerprint profiles of five commercial G. biloba nutritional supplements were obtained and compared; variation of some components among the samples was observed and fortification could be detected. In the quality control analysis of the G. biloba product this method could be viewed as complementary to specific quantitative analysis of some bioactive components of the herb.  相似文献   

7.
We describe an experimental approach for direct molecular fishing of prey protein on the surface of two types of paramagnetic particles (PMP) having different size and composition. Human microsomal cytochrome b5 (b5) and its known partner human cytochrome P450 3A5 (CYP3A5) were used as bait and prey proteins, respectively. For assessing the level of unspecific binding of background proteins, α‐fetoprotein (aFP) was used. SPR measurements were applied for quantitative analysis of trapped proteins (CYP3A5 and aFP) after fishing on PMP. It was shown that the described approach of molecular fishing on micro‐PMP provides enough prey proteins for LC‐MS/MS identification and SPR validation, so this approach can be used for discovery of new protein–protein interactions in the framework of Human Proteome Project.  相似文献   

8.
Identification of major histocompatibility complex (MHC)-associated peptides recognized by T-lymphocytes is a crucial prerequisite for the detection and manipulation of specific immune responses in cancer, viral infections, and autoimmune diseases. Unfortunately immunogenic peptides are less abundant species present in highly complex mixtures of MHC-extracted material. Most peptide identification strategies use microcapillary LC coupled to nano-ESI MS/MS in a challenging on-line approach. Alternatively MALDI PSD analysis has been applied for this purpose. We report here on the first off-line combination of nanoscale (nano) LC and MALDI TOF/TOF MS/MS for the identification of naturally processed MHC peptide ligands. These peptides were acid-eluted from human leukocyte antigen (HLA)-A2, HLA-A3, and HLA-B/-C complexes separately isolated from a renal cell carcinoma cell lysate using HLA allele-specific antibodies. After reversed-phase HPLC, peptides were further fractionated via nano-LC. This additional separation step provided a substantial increase in the number of detectable candidate species within the complex peptide pools. MALDI MS/MS analysis on nano-LC-separated material was then sufficiently sensitive to rapidly identify more than 30 novel HLA-presented peptide ligands. Peptide sequences contained perfect anchor amino acid residues described previously for HLA-A2, HLA-A3, and HLA-B7. The most promising candidate for a T-cell epitope is an HLA-B7-binding nonamer peptide derived from the tumor-associated gene NY-BR-16. To demonstrate the sensitivity of our approach we characterized peptides binding to HLA-C molecules that are usually expressed at the cell surface at approximately only 10% the levels of HLA-A or HLA-B. In fact, multiple renal cell carcinoma peptides were identified that contained anchor amino acid residues of HLA-Cw5 and HLA-Cw7. We conclude that the nano-LC MALDI MS/MS approach is a sensitive tool for the rapid and automated identification of MHC-associated tumor peptides.  相似文献   

9.
10.
An optical biosensor employing surface plasmon resonance (SPR; SPR-biosensor) is a highly efficient instrument applicable for direct real time registration of molecular interactions without additional use of any labels or coupled processes. As an independent approach it is especially effective in analysis of various ligand receptor interactions. SPR-biosensors are used for validation of studies on intermolecular interactions in complex biological systems (affinity profiling of various groups of proteins, etc.). Recently, potential application of the SPR-biosensor for molecular fishing (direct affinity binding of target molecules from complex biological mixtures on the optical biosensor surface followed by their elution for identification by LCMS/MS) has been demonstrated. Using SPR-biosensors in such studies it is possible to solve the following tasks: (a) SPR-based selection of immobilization conditions required for the most effective affinity separation of a particular biological sample; (b) SPR-based molecular fishing for subsequent protein identification by mass spectrometry; (c) SPR-based validation of the interaction of identified proteins with immobilized ligand. This review considers practical application of the SPR technology in the context of recent studies performed in the Institute of Biomedical Chemistry on molecular fishing of real biological objects.  相似文献   

11.
《MABS-AUSTIN》2013,5(5):891-900
Oxidation of methionine (Met) residues is one of several chemical degradation pathways for recombinant IgG1 antibodies. Studies using several methodologies have indicated that Met oxidation in the constant IgG1 domains affects in vitro interaction with human neonatal Fc (huFcRn) receptor, which is important for antibody half-life. Here, a completely new approach to investigating the effect of oxidative stress conditions has been applied. Quantitative ultra-performance liquid chromatography mass spectrometry (MS) peptide mapping, classical surface plasmon resonance and the recently developed FcRn column chromatography were combined with the new fast-growing approach of native MS as a near native state protein complex analysis in solution. Optimized mass spectrometric voltage and pressure conditions were applied to stabilize antibody/huFcRn receptor complexes in the gas phase for subsequent native MS experiments with oxidized IgG1 material. This approach demonstrated a linear correlation between quantitative native MS and IgG-FcRn functional analysis.

In our study, oxidation of the heavy chain Met-265 resulted in a stepwise reduction of mAb3/huFcRn receptor complex formation. Remarkably, a quantitative effect of the heavy chain Met-265 oxidation on relative binding capacity was only detected for doubly oxidized IgG1, whereas IgG1 with only one oxidized heavy chain Met-265 was not found to significantly affect IgG1 binding to huFcRn. Thus, mono-oxidized IgG1 heavy chain Met-265 most likely does not represent a critical quality attribute for pharmacokinetics.  相似文献   

12.
In the absence of an analog of PCR for proteins, the concentration detection limit (DL) becomes a real challenge. The problem may be solved by means of a combination of biospecific irreversible fishing with atomic force microscopy (AFM). AFM offers the ability to register individual molecules and their complexes, while biospecific fishing takes advantage of an affine interaction between analyte molecules spread over a large volume of biomaterial and ligand molecules immobilized on the chip surface. Fishing may be conducted in Kd‐dependent reversible mode and in Kd‐independent irreversible mode. In this study, the DLs of two previously applied proteomic approaches were determined and compared to the DL of a newly developed analytical method. The first approach, based on MS analysis of biomaterial after 2‐DE or LC separation of proteins, attained a DL at the level of 10?8–10?10 M. The second approach, based on the optical biosensor analysis of molecular interactions in the format of proteomic microarrays, had a DL of 10?9–10?10 M. Our proposed method which combines biospecific fishing with AFM allowed us to attain DL values of 10?11 M under reversible binding conditions and 10?16 M under irreversible binding conditions.  相似文献   

13.
Integrating surface plasmon resonance analysis with mass spectrometry allows detection and characterization of molecular interactions to be complemented with identification of interaction partners. We have developed a procedure for Biacore 3000 that automatically performs all steps from ligand fishing and recovery to sample preparation for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry including on-target digestion. In the model system used in this study a signal transduction protein, calmodulin, was selectively captured from brain extract by one of its interaction partners immobilized on a sensor chip. The bound material was eluted, deposited directly onto a MALDI target, and analyzed by mass spectrometry both as an intact protein and after on-target tryptic digestion. The procedure with direct deposition of recovered material on the MALDI target reduces sample losses and, in combination with automatic sample processing, increases the throughput of surface plasmon resonance mass spectrometry analysis.  相似文献   

14.
Chen WQ  Kang SU  Lubec G 《Nature protocols》2006,1(3):1446-1452
Protein profiling in the high-throughput mode is a most useful technique that allows formation of reference databases for cells and tissues and performance of comparative proteomics. In the proposed protocol protein extraction from tissues is followed by 2D gel electrophoresis (2DE) with subsequent in-gel digestion and identification of soluble proteins by two individual mass spectrometric techniques, tandem matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) and nano-liquid chromatography (nano-LC)-MS/MS. The proposed combined use of these two MS approaches leads to a very high identification rate of well-separated protein spots from a gel. In the first step 2DE separates high-abundance proteins (those visualized by nonsensitive Coomassie blue staining) that are subsequently picked, digested and aliquoted for MS applications. Protein samples not identified by MALDI-MS or MS/MS (77% of all spots) are finally unambiguously identified by nano-LC-MS/MS (total identification rate 94%). This protocol can be completed in 6 weeks.  相似文献   

15.
A novel analytical procedure for the identification of metal (Hg, Cd, Cu, Zn) complexes with individual metallothionein (MT) isoforms in biological tissues by electrospray MS/MS was developed. The sample preparation was reduced to three rapid steps: the two-fold dilution of the sample cytosol with acetonitrile, the recovery of the supernatant containing MT-complexes by centrifugation and its concentration under nitrogen flow. The replacement of reversed phase HPLC by hydrophilic interaction LC (HILIC) allowed the preservation of the unstable and low abundant metallothionein zinc-mercury mixed complexes (MT-Zn(6)Hg). The MT complexes eluted were detected by ICP MS and identified in terms of molecular mass by electrospray high resolution (100,000) MS. The identification was completed by on line demetallation and the determination of the molecular mass of the apoform, followed by amino acid sequencing in the top-down mode using high energy collision fragmentation (HCD). The method was applied to the identification of MT complexes in a white-sided dolphin (Lagenorhynchus acutus) liver homogenate. The Zn complex of the N-acetylated MT2 isoform was found to be predominant, the presence of mixed complexes with Cd, Cu and, for the first time ever, Hg, was demonstrated. The latter finding has the potential to shed new light on the mercury detoxification mechanism in marine organisms.  相似文献   

16.

Background  

Isotope-coded affinity tags (ICAT) is a method for quantitative proteomics based on differential isotopic labeling, sample digestion and mass spectrometry (MS). The method allows the identification and relative quantification of proteins present in two samples and consists of the following phases. First, cysteine residues are either labeled using the ICAT Light or ICAT Heavy reagent (having identical chemical properties but different masses). Then, after whole sample digestion, the labeled peptides are captured selectively using the biotin tag contained in both ICAT reagents. Finally, the simplified peptide mixture is analyzed by nanoscale liquid chromatography-tandem mass spectrometry (LC-MS/MS). Nevertheless, the ICAT LC-MS/MS method still suffers from insufficient sample-to-sample reproducibility on peptide identification. In particular, the number and the type of peptides identified in different experiments can vary considerably and, thus, the statistical (comparative) analysis of sample sets is very challenging. Low information overlap at the peptide and, consequently, at the protein level, is very detrimental in situations where the number of samples to be analyzed is high.  相似文献   

17.
The identification of proteins separated on two-dimensional gels is most commonly performed by trypsin digestion and subsequent matrix-assisted laser desorption ionization (MALDI) with time-of-flight (TOF). Recently, atmospheric pressure (AP) MALDI coupled to an ion trap (IT) has emerged as a convenient method to obtain tandem mass spectra (MS/MS) from samples on MALDI target plates. In the present work, we investigated the feasibility of using the two methodologies in line as a standard method for protein identification. In this setup, the high mass accuracy MALDI-TOF spectra are used to calibrate the peptide precursor masses in the lower mass accuracy AP-MALDI-IT MS/MS spectra. Several software tools were developed to automate the analysis process. Two sets of MALDI samples, consisting of 142 and 421 gel spots, respectively, were analyzed in a highly automated manner. In the first set, the protein identification rate increased from 61% for MALDI-TOF only to 85% for MALDI-TOF combined with AP-MALDI-IT. In the second data set the increase in protein identification rate was from 44% to 58%. AP-MALDI-IT MS/MS spectra were in general less effective than the MALDI-TOF spectra for protein identification, but the combination of the two methods clearly enhanced the confidence in protein identification.  相似文献   

18.
《Chirality》2017,29(10):603-609
d ‐ and l ‐Tryptophan (Trp) and d ‐ and l ‐kynurenine (KYN) were derivatized with a chiral reagent, (S )‐4‐(3‐isothiocyanatopyrrolidin‐1‐yl)‐7‐(N,N‐dimethylaminosulfonyl)‐2,1,3‐benzoxadiazole (DBD‐PyNCS), and were separated enantiomerically by high‐performance liquid chromatography (HPLC) equipped with a triazole‐bonded column (Cosmosil HILIC) using tandem mass spectrometric (MS/MS) detection. Effects of column temperature, salt (HCO2NH4) concentration, and pH of the mobile phase in the enantiomeric separation, followed by MS detection of (S )‐DBD‐PyNCS‐d ,l ‐Trp and ‐d ,l ‐KYN, were investigated. The mobile phase consisting of CH3CN/10 mM ammonium formate in H2O (pH 5.0) (90/10) with a column temperature of 50–60 °C gave satisfactory resolution (R s) and mass‐spectrometric detection. The enantiomeric separation of d ,l ‐Trp and d ,l ‐KYN produced R s values of 2.22 and 2.13, and separation factors (α) of 1.08 and 1.08, for the Trp and KYN enantiomers, respectively. The proposed LC–MS/MS method provided excellent detection sensitivity of both enantiomers of Trp and KYN (5.1–19 nM).  相似文献   

19.
20.
Most current methods for purification and identification of protein complexes use endogenous expression of affinity-tagged bait, tandem affinity tag purification of protein complexes followed by specific elution of complexes from beads, and gel separation and in-gel digestion prior to mass spectrometric analysis of protein interactors. We propose a single affinity tag in vitro pull-down assay with denaturing elution, trypsin digestion in organic solvent, and LC-ESI MS/MS protein identification using SEQUEST analysis. Our method is simple and easy to scale-up and automate, making it suitable for high-throughput mapping of protein interaction networks and functional proteomics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号