首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
Direct electrochemistry of hemoglobin in gold nanowire array   总被引:3,自引:0,他引:3  
Yang M  Qu F  Li Y  He Y  Shen G  Yu R 《Biosensors & bioelectronics》2007,23(3):414-420
Gold nanowire array has been proven to be efficient support matrixes for the immobilization of hemoglobin (Hb). The vertically oriented nanowire array provides an ordered well-defined 3D structure with nanowire density approximately 5 x 10(8)cm(2). The adsorption of ferritin onto the nanowire surface was visualized by transmission electron microscopy. When Hb was adsorbed, UV-vis absorption and Fourier transform infrared (FT-IR) spectra show no obvious denaturation of Hb in the nanowire array. The Hb-modified nanowire array exerted direct electron transfer and gave a well-defined, nearly reversible redox couple with formal potential of -0.225 V. The quantity of electroactive Hb varied with the changing of the morphology of the electrode and found to increase with the increasing of the nanowire length. Comparisons of voltammetric and quartz crystal microbalance measurements show that 70% of the Hb molecules adsorbed are electroactive when the length of the nanowire was 2 microm. Both of the Hb-modified nanowire array and the unmodified nanowire array demonstrate good electrocatalytic reduction ability for hydrogen peroxide. With the adsorption of glucose oxidase onto the bare nanowire surface, sensitive and selective glucose biosensors can be fabricated.  相似文献   

2.
Shi J  Ci P  Wang F  Peng H  Yang P  Wang L  Ge S  Wang Q  Chu PK 《Biosensors & bioelectronics》2011,26(5):2579-2584
A silicon microchannel plate (MCP) array electrode modified with over-oxidized polypyrrole (OPPy) has been fabricated to detect glucose. The morphology and structure of the electrode are characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The OPPy modified silicon MCP array electrode exhibits high electrocatalytic activity as well as excellent selectivity to the electrochemical oxidation of glucose. At a potential of +0.08 V, good sensitivity of 0.37 mA mM(-1) cm(-2) and detection limit of 2.06 μM are attained. The linear range is up to 24 mM with a linear correlation coefficient of 0.997. Furthermore, the electrode is highly resistant to interfering substances because the effects of common coexisting substances can be effectively eliminated by the OPPy film and the response in the current to interferences on the electrode surface is almost negligible. This novel electrode has high potential in nonenzymatic detection of glucose.  相似文献   

3.
Nickel oxide microfibers (NiO-MFs) were directly immobilized onto the surface of fluorine tin oxide (FTO) electrode by electrospinning and calcination without using any immobilization matrix for nonenzymatic glucose sensor. Morphology and structure of NiO-MFs were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and X-ray diffraction pattern (XRD). The electrochemical and electrocatalytic performances of the NiO-MFs modified electrodes prepared at different calcination temperatures ranging from 300 to 500°C were evaluated by cyclic voltammetry (CV). The CV results have demonstrated that NiO-MFs modified electrode prepared at 300°C displayed distinct increase in electrocatalytic activity toward the oxidation of glucose, which is explored to develop an amperometric nonenzymatic glucose sensor. The NiO-MFs prepared at 300°C based amperometric nonenzymatic glucose sensor has ultrasensitive current (1785.41 μA mM(-1) cm(-2)) response and low detection limit of 3.3×10(-8) M (signal/noise ratio (S/N)=3), which are among the best values reported in literature. Additionally, excellent selectivity and stability have also been obtained.  相似文献   

4.
Kang X  Mai Z  Zou X  Cai P  Mo J 《Analytical biochemistry》2007,363(1):143-150
Copper (Cu) nanoclusters were electrochemically deposited on the film of a Nafion-solubilized multiwall carbon nanotube (CNTs)-modified glassy carbon electrode (CNTs-GCE), which fabricated a Cu-CNTs composite sensor (Cu-CNTs-GCE) to detect glucose with nonenzyme. Transmission electron microscopy (TEM) and X-ray diffraction (XRD) were used for the characterization of the distribution of the Cu nanoclusters on the CNTs matrix. The composite of the Cu-CNTs was investigated by the electrochemical characterization of cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The preliminary study shows that the nonenzymatic sensor has synergistic electrocatalytic activity to the oxidation of glucose in alkaline media. A well applicable sensor was constructed to use for the analysis of the glucose in real blood serum samples due to the large number of electrons taking part in the oxidation process, the high apparent kinetic rate constant, and the stable operation of the electrode. The linear range for the detection of the glucose is 7.0 x 10(-7) to 3.5 x 10(-3) M with a high sensitivity of 17.76 microA mM(-1), a low detection limit of 2.1 x 10(-7) M, and a fast response time of within 5s. Experiment results also showed that the sensor has good reproducibility and long-term stability and is interference free.  相似文献   

5.
A nonenzymatic electrochemical biosensor was developed for the detection of glucose based on an electrode modified with palladium nanoparticles (PdNPs)-functioned graphene (nafion-graphene). The palladium nanoparticle-graphene nanohybrids were synthesized using an in situ reduction process. Nafion-graphene was first assembled onto an electrode to chemically adsorb Pd(2+). And Pd(2+) was subsequently reduced by hydrazine hydrate to form PdNPs in situ. Such a PdNPs-graphene nanohybrids-based electrode shows a very high electrochemical activity for electrocatalytic oxidation of glucose in alkaline medium. The proposed biosensor can be applied to the quantification of glucose with a wide linear range covering from 10 μM to 5mM (R=0.998) with a low detection limit of 1 μM. The experiment results also showed that the sensor exhibits good reproducibility and long-term stability, as well as high selectivity with no interference from other potential competing species.  相似文献   

6.
An electrocatalytic glucose sensor for in vivo application has been developed. The principle of measurement is based on the direct electrochemical oxidation of glucose at a platinum electrode without an enzymatic reaction. In an in vivo experiment with sheep the glucose sensor was tested with respect to its cross-sensitivity towards ascorbic acid, paracetamol and sulfanilamide. The influence of these substances could be reduced by an adapted calibration to such an extent, that the sensor performance could be ensured.  相似文献   

7.
Highly ordered Ni nanowire arrays (NiNWAs) were synthesized for the first time using a template-directed electropolymerization strategy with a nanopore polycarbonate (PC) membrane template, and their morphological characterization were examined by scanning electron microscopy (SEM) and transmission electron microscope (TEM). A NiNWAs based electrode shows very high electrochemical activity for electrocatalytic oxidation of glucose in alkaline medium, which has been utilized as the basis of the fabrication of a nonenzymatic biosensor for electrochemical detection of glucose. The biosensor can be applied to the quantification of glucose with a linear range covering from 5.0 × 10−7 to 7.0 × 10−3 M, a high sensitivity of 1043 μA mM−1 cm−2, and a low detection limit of 1 × 10−7 M. The experiment results also showed that the sensor exhibits good reproducibility and long-term stability, as well as high selectivity with no interference from other oxidable species.  相似文献   

8.
Nitrogen doped graphene (NG) was prepared by thermally annealing graphite oxide and melamine mixture. After characterization by atomic force microscopy and X-ray photoelectron spectroscopy etc., the electrochemical sensor based on NG was constructed to simultaneously determine small biomolecules such as ascorbic acid (AA), dopamine (DA) and uric acid (UA). Due to its unique structure and properties originating from nitrogen doping, NG shows highly electrocatalytic activity towards the oxidation of AA, DA and UA. The electrochemical sensor shows a wide linear response for AA, DA and UA in the concentration range of 5.0×10(-6) to 1.3×10(-3)M, 5.0×10(-7) to 1.7×10(-4)M and 1.0×10(-7) to 2.0×10(-5)M with detection limit of 2.2×10(-6)M, 2.5×10(-7)M and 4.5×10(-8)M at S/N=3, respectively. These results demonstrate that NG is a promising candidate of advanced electrode material in electrochemical sensing and other electrocatalytic applications.  相似文献   

9.
Novel nickel and copper oxide nanoparticle modified polyaniline (PANI) nanofibers (NiO/CuO/PANI) were fabricated and used as a non-enzymatic sensor for detecting glucose. PANI nanofibers were prepared through electrodeposition, whereas nickel and copper oxide nanoparticles were deposited on PANI nanofibers by electrodeposition and electrochemical oxidation in situ. The morphology and structure of NiO/CuO/PANI nanocomposites were characterized by field emission scanning electron microscopy (FE–SEM), X-ray diffraction (XRD), Raman spectroscopy, and Fourier transform infrared (FT–IR). The as-prepared NiO/CuO/PANI electrode was employed for non-enzymatic glucose detection in alkaline electrolyte and showed better electrocatalytic activity compared with the PANI, CuO/PANI, and NiO/PANI electrodes. Consequently, an amperometric electrode of glucose was achieved under 0.6 V versus Ag/AgCl with a wide linear range from 20 to 2500 μM (R2 = 0.9978) and a low detection limit of 2.0 μM (signal/noise [S/N] = 3). This electrode can effectively analyze glucose concentration in human serum samples, avoiding interference, and is a promising non-enzymatic glucose sensor due to its low overpotential, high sensitivity, good selectivity and stability, fast response, and low cost.  相似文献   

10.
An amperometric glucose biosensor with glucose oxidase (GOx) immobilized into palladium hexacyanoferrate (PdHCF) hydrogel has been prepared and evaluated. The sensor was based on a two-layer configuration with biocatalytic and electrocatalytic layers separately deposited onto the electrode. To reduce the overpotential for reduction of hydrogen peroxide liberated in the enzyme catalyzed oxidation of glucose, an inner thin layer of nickel hexacyanoferrate (NiHCF) electrodeposited onto the surface of graphite electrode was used as an electrocatalyst. As an outer layer, the hydrogel of palladium hexacyanoferrate with entrapped glucose oxidase was used. Under optimal operating conditions (pH 5.0 and E = -0.075 V versus calomel (3.0 M KCl) reference electrode), sensor showed high sensitivity to glucose (0.3-1.0 microA/mM) and a response time of less than 30s. The linear response to glucose was obtained in the concentration range between 0.05 and 1.0 mM in batch analysis mode and 0-7.0 mM in FIA. During the 32 days testing period, no significant decrease in the sensor sensitivity was observed. The sensor was applied for the determination of glucose concentration in fruit juice and yoghurt drink, and the results obtained showed good correlation with results obtained by reference spectrophotometric enzyme method.  相似文献   

11.
In this work, poly(aniline-co-o-aminophenol) (copolymer) was used as an electron transfer mediator in the electrochemical oxidation of catechol due to its reversible redox over a wide range of pH. The experimental results indicate that the anodic peak potential of catechol at the copolymer electrode is lower than that at the platinum electrode in a solution consisting of catechol and sodium sulfate with pH 5.0, and the activation energy for the electrochemical oxidation of catechol at the copolymer electrode is low (23.6 kJ mol(-1)). These are strong evidence for the electrocatalytic oxidation of catechol at the copolymer electrode. The -OH group on the copolymer chain plays an important role in the electron transfer between the copolymer electrode and catechol in the solution. Based on the catalytic oxidation, the copolymer is used as a sensor to determine the concentration of catechol. The response current of the sensor depends on the concentration of catechol, pH, applied potential and temperature. At 0.55 V (versus saturated calomel reference electrode (SCE)) and pH 5.0, the sensor has a fast response (about 10s) to catechol and good operational stability. The sensor shows a linear response range between 5 and 80 microM catechol with a correlation coefficient of 0.997. It was found that phenol and resorcinol cannot be oxidized at the copolymer electrode at potentials < or =0.55 V, so controlling the sensor potential affords a good way of avoiding the effect of phenol and resorcinol on the determination of catechol.  相似文献   

12.
A novel amperometric nonenzymatic glucose sensor based on Au-doped NiO nanobelts has been successfully fabricated and applied to nonenzymatic glucose detection. Its electrochemical behavior towards the oxidation of glucose was compared with NiO nanofibers and Au microparticles prepared with a similar procedure. The NiO-Au hybrid nanobelts modified electrode displays greatly enhanced electrocatalytic activity towards glucose oxidation, revealing a synergistic effect between the matrix NiO and the doped Au. The as-prepared NiO-Au nanobelts based glucose sensor displays significantly lower onset potential, lower detection limit, higher sensitivity, and wider linear range than that of pristine NiO nanofibers modified electrode. Moreover, Au nanoparticles distributed in NiO nanofibers enabled amperometric glucose detection with insignificant interference from ascorbic acid and uric acid. These results indicate that the NiO-Au hybrid nanobelt is a promising candidate in the development of highly sensitive and selective nonenzymatic glucose sensors.  相似文献   

13.
A non-enzymatic glucose sensor of multi-walled carbon nanotube-ruthenium oxide/composite paste electrode (MWCNT-RuO(2)/CPE) was developed. The electrode was characterized by using XRD, SEM, TEM and EIS. Meanwhile, cyclic voltammetry and amperometry were used to check on the performances of the MWCNT-RuO(2)/CPE towards glucose. The proposed electrode has displayed a synergistic effect of RuO(2) and MWCNT on the electrocatalytic oxidation of glucose in 3M NaOH. This was possible via the formation of transitions of two redox pairs, viz. Ru(VI)/Ru(IV) and Ru(VII)/Ru(VI). A linear range of 0.5-50mM glucose and a limit of detection of 33μM glucose (S/N=3) were observed. There was no significant interference observable from the traditional interferences, viz. ascorbic acid and uric acid. Indeed, results so obtained have indicated that the developed MWCNT-RuO(2)/CPE would pave the way for a better future to glucose sensor development as its fabrication was without the use of any enzyme.  相似文献   

14.
The electrochemical performance of a new glucose biosensor is reported. The glucose biosensor is developed using glucose oxidase (GOD) and ferrocene encapsulated palladium (Pd)-linked organically modified sol-gel glass (ORMOSIL) material incorporated within graphite paste electrode. The ORMOSIL material incorporated within graphite paste electrode behaves as an excellent electrocatalyst for the oxidation of enzymatically reduced GOD. The electrochemical behavior of new glucose biosensor has been examined by cyclic volammetry and amperometric measurements. The bioelectrocatalysis of ORMOSIL embedded within graphite paste as a function of storage time and varying concentration of ORMOSIL is reported. The initial amperometric response on glucose sensing is recorded to be 145 microA at 15% (w/w) concentration of the ORMOSIL which is decreased to 20 microA at 5% of the same keeping GOD concentration constant. The variation of electrochemical behavior of the ORMOSIL embedded within graphite paste as a function of time has also been studied based on cyclic voltammetry. The voltammograms showing the reversible electrochemistry of ORMOSIL encapsulated ferrocene is changed into a plateau shape as a function of time, however, the electrocatalytic behavior is still retained. The practical usability of new glucose sensor has been compared with earlier developed glucose sensor. The sensitivity, response time and linearity of the new glucose biosensor are found to be excellent over earlier reported glucose biosensor. The amperometric response, calibration curve and practical applications of new glucose sensor are reported.  相似文献   

15.
An ultrasensitive electrochemical immunoassay (EIA) for the detection of carcinoembryonic antigen (CEA) is described in this report. The assay involves utilizing enzyme-catalyzed deposition of a redox polymer and electrocatalytic oxidation of ascorbic acid (AA) by the deposited redox polymer, a dual-amplification scheme to enhance analytical signals. Briefly, CEA capturing antibody and redox polymer anchoring agent were covalently immobilized on a gold electrode. After incubating with CEA, the electrode was treated in detection antibody-glucose oxidase conjugate solution. Thereafter, it was dipped into the redox polymer solution. Upon the addition of glucose, the redox polymer was enzymatically reduced and deposited on the electrode surface. The deposited redox polymer exhibits excellent electrocatalytic activity towards the oxidation of AA. Consequently, CEA could be quantified amperometrically. This electrochemical immunoassay combines the specificity of the immunological reaction with the sensitivity of the doubly amplified electrochemical detection.  相似文献   

16.
Sensitive electrochemical immunosensor for the detection of protein biomarker tumor necrosis factor α (TNF-α) was reported that uses ferrocene carboxylic acid (Fc) functionalized self-assembled peptide nanowire (Fc-PNW) as sensor platform and glucose oxidase (GOx) modified gold nanorod (GNR) as label. Greatly enhanced sensitivity is achieved based on a dual signal amplification strategy: first, the synthesized Fc-PNW used as the sensor platform increased the loading of primary anti-TNF-α antibody (Ab(1)) onto electrode surface due to its large surface area. At the same time, the Fc moiety on the nanowire is used as a mediator for GOx to catalyze the glucose reaction. Second, multiple GOx and secondary anti-TNF-α antibody (Ab(2)) molecules are bounded onto each GNR to increase the sensitivity of the immunosensor. After the preparation of the immunosensor based on the traditional sandwich protocol, the response of the immunosensor towards glucose was used as a signal to differentiate various concentrations of TNF-α. The resulting immunosensor has high sensitivity, wide linear range (0.005-10ng/mL) and good selectivity. This immunosensor preparation strategy is a promising platform for clinical screening of protein biomarkers.  相似文献   

17.
A nonenzymatic electrochemical sensor device was fabricated for glucose detection based on nickel nanoparticles (NiNPs)/straight multi-walled carbon nanotubes (SMWNTs) nanohybrids, which were synthesized through in situ precipitation procedure. SMWNTs can be easily dispersed in solution after mild sonication pretreatment, which facilitates the precursor of NiNPs binding to their surface and results in the homogeneous distribution of NiNPs on the surface of SMWNTs. The morphology and component of the nanohybrids were characterized by scanning electron microscopy (SEM) and X-ray powder diffraction (XRD), respectively. Cyclic voltammetry (CV) and amperometry were used to evaluate the catalytic activity of the NiNPs/SMWNTs nanohybrids modified electrode towards glucose. It was found that the nanohybrids modified electrode showed remarkably enhanced electrocatalytic activity towards the oxidation of glucose in alkaline solution compared to that of the bare glass carbon electrode (GCE), the NiNPs and the SMWNTs modified electrode, attributing to the synergistic effect of SMWNTs and Ni2+/Ni3+ redox couple. Under the optimal detection conditions, the as-prepared sensors exhibited linear behavior in the concentration range from 1 μM to 1 mM for the quantification of glucose with a limit of detection of 500 nM (3σ). Moreover, the NiNPs/SMWNTs modified electrode was also relatively insensitive to commonly interfering species such as ascorbic acid (AA), uric acid (UA), dopamine (DA), galactose (GA), and xylose (XY). The robust selectivities, sensitivities, and stabilities determined experimentally indicated the great potential of NiNPs/SMWNTs nanohybrids for construction of a variety of electrochemical sensors.  相似文献   

18.
A new amperometric biosensor, based on adsorption of glucose oxidase (GOD) at the platinum nanoparticle-modified carbon nanotube (CNT) electrode, is presented in this article. CNTs were grown directly on the graphite substrate. The resulting GOD/Pt/CNT electrode was covered by a thin layer of Nafion to avoid the loss of GOD in determination and to improve the anti-interferent ability. The morphologies and electrochemical performance of the CNT, Pt/CNT, and Nafion/GOD/Pt/CNT electrodes have been investigated by scanning electron microscopy, cyclic voltammetry, and amperometric methods. The excellent electrocatalytic activity and special three-dimensional structure of the enzyme electrode result in good characteristics such as a large determination range (0.1-13.5mM), a short response time (within 5s), a large current density (1.176 mA cm(-2)), and high sensitivity (91mA M(-1)cm(-2)) and stability (73.5% remains after 22 days). In addition, effects of pH value, applied potential, electrode construction, and electroactive interferents on the amperometric response of the sensor were investigated and discussed. The reproducibility and applicability to whole blood analysis of the enzyme electrode were also evaluated.  相似文献   

19.
Selective detection of cysteine in serum samples was achieved on a graphene nanoribbon (GNR) and Nafion nanocomposite modified electrode with high precision. The superior conductivity and abundant amount of active chemical oxygen groups on the edge of GNR led to extremely highly electrocatalytic activity of GNR towards the electrochemical oxidation of cysteine at +0.025 V. The electrocatalytic behavior was further used for sensitive detection of cysteine by differential pulse voltammetry. Under optimized conditions, the calibration curve was linear in the range from 25 nM to 500 μM. The electrochemical sensor showed strong antifouling ability, good stability and selectivity. It could effectively exclude the interferences from other kinds of biothiols and the biological relevant species, thus had great perspective for in vivo analysis of biological samples.  相似文献   

20.
A new glucose biosensor has been fabricated by immobilizing glucose oxidase into a sol-gel composite at the surface of a basal plane pyrolytic graphite (bppg) electrode modified with multiwall carbon nanotube. First, the bppg electrode is subjected to abrasive immobilization of carbon nanotubes by gently rubbing the electrode surface on a filter paper supporting the carbon nanotubes. Second, the electrode surface is covered with a thin film of a sol-gel composite containing encapsulated glucose oxidase. The carbon nanotubes offer excellent electrocatalytic activity toward reduction and oxidation of hydrogen peroxide liberated in the enzymatic reaction between glucose oxidase and glucose, enabling sensitive determination of glucose. The amperometric detection of glucose is carried out at 0.3 V (vs saturated calomel electrode) in 0.05 M phosphate buffer solution (pH 7.4) with linear response range of 0.2-20 mM glucose, sensitivity of 196 nA/mM, and detection limit of 50 microM (S/N=3). The response time of the electrode is < 5s when it is stored dried at 4 degrees C, the sensor showed almost no change in the analytical performance after operation for 3 weeks. The present carbon nanotube sol-gel biocomposite glucose oxidase sensor showed excellent properties for the sensitive determination of glucose with good reproducibility, remarkable stability, and rapid response and in comparison to bulk modified composite biosensors the amounts of enzyme and carbon nanotube needed for electrode fabrication are dramatically decreased.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号