首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
上转磷光技术在快速生物分析中的应用   总被引:10,自引:0,他引:10  
上转磷光技术 (UPT)是基于上转磷光材料 (UCP)而发展起来的一种新型标记技术。UCP是由几种稀土金属元素掺杂于某些晶体的晶格中构成的纳米级颗粒。由于独特的结构 ,UCP可由红外光激发而发射可见光———上转磷光。这种特殊性质使UCP作为标记物在生物分析中 ,以无本底干扰、无淬灭、适于多重分析和定量分析等显著优势 ,从本质上有别于传统标记物。UCP将在快速免疫分析、微点阵、高通量药物筛选、基因组学研究、外科手术组织成像、食品环境检测以及生化战防御等多方面得到广泛地应用。  相似文献   

2.
In this study, an up‐converting phosphor technology‐based lateral‐flow (UPT‐LF) assay was developed to detect severe fever with thrombocytopenia syndrome virus (SFTSV) total antibodies rapidly and specifically. SFTSV recombinant N protein (SFTSV‐rNP) was coated on analytical membrane for sample capture, up‐converting phosphor (UCP) particles were used as the reporter, the luminescence emitted by UCP particles was converted to a measurable signal by a biosensor. The performance of UPT‐LF assay was evaluated by testing 302 field serum samples by ELISA (enzyme‐linked immunosorbent assay), Western blotting and UPT‐LF assay. UPT‐LF assay exhibited a lower detection limit than ELISA, and a satisfied level of agreement was exhibited by Kappa statistics (Kappa coefficient = 0.938). Considering Western blotting as the reference for comparison, the sensitivity and specificity of UPT‐LF assay could reach 98.31% and 100%. UPT‐LF assay showed no specific reaction with hantavirus total serum antibodies, which avoids the misdiagnosis of SFTSV from hantavirus that could cause similar clinical symptoms. UPT‐LF assay was able to achieve acceptable results within 15 min and needed only 10 μL sample for each test. As a whole, UPT‐LF assay is a candidate method for on‐site surveillance of SFTSV total antibodies owing to its excellent sensitivity, specificity, stability, easy operation and for being less time consuming.  相似文献   

3.

Background

Field-applicable tests detecting asymptomatic Mycobacterium leprae (M. leprae) infection or predicting progression to leprosy, are urgently required. Since the outcome of M. leprae infection is determined by cellular- and humoral immunity, we aim to develop diagnostic tests detecting pro-/anti-inflammatory and regulatory cytokines as well as antibodies against M. leprae. Previously, we developed lateral flow assays (LFA) for detection of cytokines and anti-PGL-I antibodies. Here we evaluate progress of newly developed LFAs for applications in resource-poor settings.

Methods

The combined diagnostic value of IP-10, IL-10 and anti-PGL-I antibodies was tested using M. leprae-stimulated blood of leprosy patients and endemic controls (EC). For reduction of the overall test-to-result time the minimal whole blood assay time required to detect distinctive responses was investigated. To accommodate LFAs for field settings, dry-format LFAs for IP-10 and anti-PGL-I antibodies were developed allowing storage and shipment at ambient temperatures. Additionally, a multiplex LFA-format was applied for simultaneous detection of anti-PGL-I antibodies and IP-10. For improved sensitivity and quantitation upconverting phosphor (UCP) reporter technology was applied in all LFAs.

Results

Single and multiplex UCP-LFAs correlated well with ELISAs. The performance of dry reagent assays and portable, lightweight UCP-LF strip readers indicated excellent field-robustness. Notably, detection of IP-10 levels in stimulated samples allowed a reduction of the whole blood assay time from 24 h to 6 h. Moreover, IP-10/IL-10 ratios in unstimulated plasma differed significantly between patients and EC, indicating the feasibility to identify M. leprae infection in endemic areas.

Conclusions

Dry-format UCP-LFAs are low-tech, robust assays allowing detection of relevant cytokines and antibodies in response to M. leprae in the field. The high levels of IP-10 and the required shorter whole blood assay time, render this cytokine useful to discriminate between leprosy patients and EC.  相似文献   

4.
The effects of aldehyde fixatives on immunochemical detection of cytoskeletal proteins were demonstrated by applying several quantitative assays to evaluate antigen conservation. Immunologically detectable brain spectrin (240/235) was measured by dot-immunobinding and quantitative immunodot assay using a polyclonal antibody. Paraformaldehyde fixation led to a 43-66% reduction in brain spectrin (240/235) immunodetection, and increasing glutaraldehyde concentrations decreased the immunological detection even more. Quantitative cryosection immunoassay and immunocytochemical localization confirmed the aldehyde sensitivity of brain spectrin (240/235). Brain spectrin (240/235) immunoreactivity decreased with increasing protein crosslinking and was dependent on glutaraldehyde concentration and post-fixation period. The assays were also used to test for conservation of antigenicity of neurofilament proteins by two monoclonal antibodies. Neurofilament detection was abolished in brain tissue after aldehyde fixation. The described methods allow screening within 24 hr of many fixation conditions by use of purified proteins as well as brain tissue samples, and allow an estimate of fixative influence on the conservation of protein antigenicity.  相似文献   

5.
An earlier reported laboratory assay, performed in The Netherlands, to diagnose Schistosoma infections by detection of the parasite antigen CAA in serum was converted to a more user-friendly format with dry reagents. The improved assay requires less equipment and allows storage and worldwide shipping at ambient temperature. Evaluation of the new assay format was carried out by local staff at Ampath Laboratories, South Africa. The lateral flow (LF) based assay utilized fluorescent ultrasensitive up-converting phosphor (UCP) reporter particles, to be read by a portable reader (UPlink) that was also provided to the laboratory. Over a period of 18 months, about 2000 clinical samples were analyzed prospectively in parallel with a routinely carried out CAA–ELISA. LF test results and ELISA data correlated very well at CAA concentrations above 300 pg/mL serum. At lower concentrations the UCP–LF test indicates a better performance than the ELISA. The UCP–LF strips can be stored as a permanent record as the UCP label does not fade. At the end of the 18 months testing period, LF strips were shipped back to The Netherlands where scan results obtained in South Africa were validated with different UCP scanning equipment including a novel, custom developed, small lightweight UCP strip reader (UCP-Quant), well suited for testing in low resource settings.  相似文献   

6.
In hybridoma screening, quantitative kinetic evaluation is difficult since the concentration of each antibody in the hybridoma supernatant is unknown. From modeling calculations, we hypothesized that the ratio of two different antigen-antibody concentrations might allow discrimination of high-affinity monoclonal antibodies irrespective of the antibody concentration. Using anti-alpha-fetoprotein monoclonal antibodies of known affinity, we set the signal ratio of a time-resolved assay at >0.1, in which the antigen concentrations were 10 and 100 ng/mL. From anti-alpha-fetoprotein hybridoma screening with this assay, it was possible to effectively select high-affinity monoclonal antibodies with KD values below 1x10(-8) M. High-sensitivity sandwich enzyme-linked immunosorbent assay which detects domain III of alpha-fetoprotein has been established using selected high-affinity monoclonal antibodies. This screening method is useful for selection of high-affinity monoclonal antibodies of potential diagnostic value.  相似文献   

7.

Background

Elimination of schistosomiasis as a public health problem and interruption of transmission in selected areas are key goals of the World Health Organization for 2025. Conventional parasitological methods are insensitive for the detection of light-intensity infections. Techniques with high sensitivity and specificity are required for an accurate diagnosis in low-transmission settings and verification of elimination. We determined the accuracy of a urine-based up-converting phosphor-lateral flow circulating anodic antigen (UCP-LF CAA) assay for Schistosoma haematobium diagnosis in low-prevalence settings in Zanzibar, Tanzania.

Methodology

A total of 1,740 urine samples were collected in 2013 from children on Pemba Island, from schools where the S. haematobium prevalence was <2%, 2–5%, and 5–10%, based on a single urine filtration. On the day of collection, all samples were tested for microhematuria with reagent strips and for the presence of S. haematobium eggs with microscopy. Eight months later, 1.5 ml of urine from each of 1,200 samples stored at -20°C were analyzed by UCP-LF CAA assay, while urine filtration slides were subjected to quality control (QCUF). In the absence of a true ‘gold’ standard, the diagnostic performance was calculated using latent class analyses (LCA).

Principal Findings

The ‘empirical’ S. haematobium prevalence revealed by UCP-LF CAA, QCUF, and reagent strips was 14%, 5%, and 4%, respectively. LCA revealed a sensitivity of the UCP-LF CAA, QCUF, and reagent strips of 97% (95% confidence interval (CI): 91–100%), 86% (95% CI: 72–99%), and 67% (95% CI: 52–81%), respectively. Test specificities were consistently above 90%.

Conclusions/Significance

The UCP-LF CAA assay shows high sensitivity for the diagnosis of S. haematobium in low-endemicity settings. Empirically, it detects a considerably higher number of infections than microscopy. Hence, the UCP-LF CAA employed in combination with QCUF, is a promising tool for monitoring and surveillance of urogenital schistosomiasis in low-transmission settings targeted for elimination.  相似文献   

8.
Antibodies against Escherichia coli-expressed uncoupling protein-2 (UCP2) and uncoupling protein-3 (UCP3) were raised by operating the blotted proteins into the spleen of minipigs. The antisera reacted more intensively with the recombinant UCP2 and UCP3 than with uncoupling protein-1 (UCP1) isolated from brown adipose tissue. Moreover, anti-UCP2 and cross-reacting anti-UCP3 antibodies identified the presence of the UCP2/3 antigen in isolated mitochondria from rat heart, rat kidney, rat brain, rabbit epididymal white adipose tissue, hamster brown adipose tissue, and rabbit skeletal muscle. It has been concluded that UCP2 is expressed in these tissues (UCP3 in skeletal muscle); however their existence in mitochondria had not previously been demonstrated.  相似文献   

9.
Despite the wide acceptance of yeast two-hybrid (Y2H) system for protein-protein interaction analysis and discovery, conventional Y2H assays are not well suited for high-throughput screening of the protein interaction network (“interactome”) on a genomic scale due to several limitations, including labor-intensive agar plating and colony selection methods associated with the use of nutrient selection markers, complicated reporter analysis methods associated with the use of LacZ enzyme reporters, and incompatibility of the liquid handling robots. We recently reported a robust liquid culture Y2H system based on quantitative analysis of yeast-enhanced green fluorescent protein (yEGFP) reporters that greatly increased the analysis throughput and compatibility with liquid handling robots. To further advance its utility in high-throughput complementary DNA (cDNA) library screening, we report the development of a novel surface display Y2H (sdY2H) library screening system with uniquely integrated surface display hemagglutination (sdHA) antigen and yEGFP reporters. By introduction of a surface reporter sdHA into the yEGFP-based Y2H system, positive Y2H targets are quickly isolated from library cells by a simple magnetic separation without a large plating effort. Moreover, the simultaneous scoring of multiple reporters, including sdHA, yEGFP, and conventional nutrient markers, greatly increased the specificity of the Y2H assay. The feasibility of the sdY2H assay on large cDNA library screening was demonstrated by the successful recovery of positive P53/T interaction pairs at a target-to-background ratio of 1:1,000,000. Together with the massive parallel DNA sequencing technology, it may provide a powerful proteomic tool for high-throughput interactome mapping on a genomic scale.  相似文献   

10.
With the purpose of evaluating the available methodology for neurocysticercosis (NCC) diagnosis, 60 neurological patients were studied during a 4-year period in Honduras. Neurological evaluation, Computed Tomography (CT), cysticercosis Enzyme-Linked Immunoelectrotransfer blot (EITB) assay, electroencephalographic studies, and collection of epidemiological information were performed to assess a final diagnosis. The presenting clinical manifestations were: epileptic seizures (52%), headache without intracranial pressure (27%) and intracranial hypertension (10%). A protocol for the diagnosis of NCC is suggested. According to this protocol, patients with active (live) cysticercus and/or antibodies in Cerebrospinal fluid (CSF) were diagnosed as definitive cases of NCC, whereas those with only brain calcifications were diagnosed as probable cases. NCC diagnosis was definitive in 14 (23%) patients, probable in 32 (54%) and ruled out in 14 (23%). Of the patients with epileptic seizures, six (19%) had definitive and 20 (65%) had probable NCC. Overall seropositivity was 28%. EITB positivity varied from 14 to 100%, and from 20 to 35% in definitive and probable cases of NCC, respectively. When compared to CT, EITB overall sensitivity for definitive, active cases, was 50% in serum and 63% in CSF. These results suggest that brain images combined with neurological evaluation remains the best approach for neurocysticercosis diagnosis, and that EITB, even though its variable sensitivity, offers valuable information, especially if performed in CSF.  相似文献   

11.
摘 要 目的 建立基于报告基因的组胺H3受体(H3R)激活剂的高通量筛选模型,用此模型对收集到的中草药化合物组分进行筛选,以发现新的组胺H3R激活剂。 方法 将H3R基因质粒(H3R/pCDNA3.1-hygro)与报告基因质粒(3XCRE-LUC)按3:1的比例共转染入HEK293细胞,建立了稳定的H3R配体的报告基因筛选细胞株。激活剂与细胞表面H3R结合后,激活相应的信号通路,调节Forskolin刺激后的报告基因的表达,通过测定荧光素酶报告基因表达水平的变化,评估激活剂影响H3受体的生物活性。 结果 通过对筛选条件,如激活剂孵育时间、Forskolin终浓度、化合物溶剂的选择、溶剂DMSO终浓度等的优化,建立了可靠的筛选方法,并对多种中草药萃取物进行了筛选,找到了两种对H3R有活性的中药组分。结论 建立的细胞模型可以有效的应用于以组胺H3受体为靶点的高通量药物筛选。  相似文献   

12.
Paired samples of cerebrospinal fluid (CSF) and serum of 30 patients--10 with active, 10 with inactive neurocysticercosis (NCC), and 10 control subjects--were evaluated by enzyme-linked immunosorbent assay (ELISA) using two Taenia crassiceps metacestode extracts as antigen in order to detect IgG antibodies. In active NCC, high levels of IgG were detected (p < 0.05). The CSF samples showed 80% (CI 72-88) of reactivity in the saline extract (S) and 90% (CI 84-95) in sodium dodecyl sulphate (SDS) and the serum samples were reactive in 90% (CI 84-95) and 100% (CI 98-100) in the S and SDS antigenic extracts, respectively. The use of the paired samples of CSF and serum in active NCC showed equivalent results suggesting that the serum samples could be used as a screening in those patients whose CSF puncture is counter-indicated.  相似文献   

13.
Three mitochondrial uncoupling proteins (UCP1, 2, 3) have been described. The proton transport activity of UCP1 triggers mitochondrial uncoupling and thermogenesis but the roles of UCP2 and UCP3 remain debated. Accordingly, compounds able to finely control the proton permeability of the mitochondrial inner membrane where and when needed may have enormous practical consequences. Using purified hamster brown adipose tissue UCP1 reconstituted in liposomes, we describe herein a robust assay allowing the measurement of this artificial membrane conductance to protons in a format compatible with high-throughput screening. The assay was initially developed with a known chemical protonophore in an aproteic system. Then, using the proteolipid reconstituted UCP1 preparation, we assessed the assay with known modulators of UCP1, particularly retinoic acid and guanosine 5'-triphosphate. The system was developed for a 96-well plate format. We then exemplified its use by generating primary data on a set of compounds screened in this system. These primary data will open new routes for the search of candidate compounds that will help biochemical studies on UCPs.  相似文献   

14.
In the attempt to define a strategy for screening new monoclonal antibodies (mAb) that could be appropriate for clinical application in oncology, we evaluated the suitability of three methods: a direct internalization assay (DIA), an indirect internalization assay (IIA) and an indirect cytotoxicity assay (ICA), by applying them to already selected mAb. The latter were directed against three antigenic systems [38-kDa glycoprotein (gp38), epidermal growth factor receptor, and theneu oncogene product], which, according to their tumor selectivity, could be considered suitable for mAb-guided therapy. The dose-dependent and time-dependent binding, as well as the low intraassay variability, demonstrated the reliability of the three tests. However, a certain degree of inter-assay variability was observed in each one, the highest value being that found when IIA was applied. Furthermore, the degree of variability, as well as the predictability, seemed to be more related to the mAb/antigen (Ag) combination used rather than to the test applied. From the overall data we suggest a procedure to be applied for screening purposes. As a first approach applied to the raw material, ICA is only suitable for screening in the case of an already selected toxin whereas IIA may be helpful to eliminate the true negative mAb. After purification of the relevant mAb a repeated analysis using DIA could allow the selection of true internalizing mAb. However, this second screening should be followed by a further analysis of the fate of the Ag–Ab complex after internalization.  相似文献   

15.
16.
Phosphodiesterases (PDEs) hydrolyze cyclic nucleotides, cyclic adenosine monophosphate (cAMP) and guanosine monophosphate (cGMP) into inactive 5' monophosphates, and exist as 11 families. Inhibitors of PDEs allow the elevation of cAMP and cGMP, which leads to a variety of cellular effects including airway smooth muscle relaxation and inhibition of cellular inflammation or of immune responses. PDE4 inhibitors specifically prevent the hydrolysis of cAMP. We have validated the manually developed reporter gene assay in a high-throughput screening format that allows for fast and cost-effective identification of potential inhibitors of PDE4 isozymes. The assay is sensitive and robust, with a Z' value of >0.5. The assay is also amenable to 384-well format.  相似文献   

17.
Background. Noninvasive diagnostic tests are useful as screening tools for Helicobacter pylori infection in pediatric populations. The aim of this study was to evaluate performance of the immunoblot assay, Helico Blot 2.1, for the diagnosis of H. pylori infection in symptomatic children. Materials and Methods. Immunoblot assay was used for detection of IgG antibodies to specific H. pylori proteins and to a recombinant H. pylori antigen, CIM marker. The study was performed on sera collected from 134 symptomatic, untreated children (mean age, 9.1 ± 3.2 years; range, 1–14 years). H. pylori infection status was determined by culture, histology and rapid urease test. Results. Immunoblot assay yielded a positive result in 71 of the 72 infected patients (sensitivity 98.6%) and in eight of the 62 noninfected ones (specificity 87.1%). The predictive values for a positive and a negative result were 89.9% and 98.2%, respectively. The performance of the CIM band alone, as a marker for H. pylori infection status, was also evaluated. This band was present on the blot of 71 infected patients and on four of the 62 H. pylori‐negative patients. The sensitivity, specificity, PPV and NPV of the CIM antigen were 98.6%, 93.5%, 94.7% and 98.3%, respectively. Conclusions. The immunoblot assay Helico Blot 2.1 is a suitable noninvasive test for the serodiagnosis of H. pylori infection in children. The good level of performance demonstrated by the novel recombinant antigen CIM suggests it may be a useful contribution to the qualitative and quantitative performance of the Helico Blot 2.1 in pediatric populations.  相似文献   

18.
19.
A highly specific and novel dual-label time-resolved immunofluorometric assay was developed exploiting the unique emission wavelengths of the intrinsically fluorescent terbium (Tb3+) and europium (Eu3+) tracers for the simultaneous detection of human immunodeficiency virus 1 (HIV-1) and hepatitis B virus (HBV) infections, respectively. HIV-1 infection was detected using a double antigen sandwich format wherein anti-HIV-1 antibodies were captured using an in vivo biotinylated version of a chimeric HIV-1 antigen and revealed using the same antigen labeled with Tb3+ chelate. Hepatitis B surface antigen (HBsAg), which served as the marker of HBV infection, was detected in a double antibody sandwich using two monoclonal antibodies (mAbs), one chemically biotinylated to capture, and the other labeled with Eu3+ nanoparticles, to reveal. The performance of the assay was evaluated using a collection (n = 60) of in-house and commercially available human sera panels. This evaluation showed the dual-label assay to possess high degrees of specificity and sensitivity, comparable to those of commercially available, single analyte-specific kits for the detection of HBsAg antigen and anti-HIV antibodies. This work demonstrates the feasibility of developing a potentially time- and resource-saving multiplex assay for screening serum samples for multiple infections in a blood bank setting.  相似文献   

20.
目的:构建解偶联蛋白UCP1启动子荧光素酶报告基因载体,为寻找调控UCP1表达的小分子化合物提供有效工具。方法:从小鼠基因组DNA中PCR扩增小鼠UCP1启动子上游2000 bp序列,并将该序列连接到荧光素酶报告基因载体p GL3-basic中,构建p GL3-UCP1启动子。测序正确后,提取质粒,然后将上述载体与p RL-TK载体共转染至HEK293细胞、小鼠白色脂肪前体细胞和小鼠棕色脂肪前体细胞,48 h后裂解细胞检测荧光素酶的活性。结果:通过PCR成功扩增获得了目的片段,并将其克隆至p GL3-basic中。与细胞内源UCP1表达水平相似,荧光素酶报告系统表明构建的p GL3-UCP1在棕色脂肪细胞中启动子活性最高,在白色脂肪细胞中活性较低,在HEK293细胞中基本没有活性。同时β3肾上腺素受体激动剂CL 316,243同样能够上调p GL3-UCP1的启动子活性。结论:成功构建了小鼠UCP1启动子荧光素酶报告基因载体,并证明在棕色脂肪细胞中,该启动子具有很强的启动子活性,而在白色脂肪和HEK293细胞中,启动子活性很低。该启动子报告系统有望为寻找激活UCP1的小分子化合物提供重要平台。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号