1.

Aim

The aim of this study is to evaluate differences in terms of the setup errors observed using kV planar image compared to CBCT for oesophageal cancer patients.

Background

Planar kV images are quick to acquire but only allow the observation of bony structures. CBCT allows the evaluation of soft tissues, which includes the oesophagus (and tumour) and OAR, giving a more accurate verification of the positioning.

Materials and Methods

All patients were imaged with both techniques between January 2012 and March 2014 were included in the study (16 patients, 212 kV images and 116 CBCT images). Differences between the setup errors observed on the two images modalities were studied. A correlation study between TNM staging, tumour location and immobilization systems with setup errors was also done. Finally, the calculation of systematic and random errors allowed to determine the CTV–PTV margin.

Results

A significant discrepancy (p < 0.05) between the setup errors observed with kV and CBCT was observed in the lateral direction. No statistical correlation was found between setup errors and tumour location, immobilization system or TNM staging. The CTV–PTV margin was smaller with CBCT in the vertical (0.6 cm vs. 0.9 cm) and longitudinal (0.7 cm vs. 1 cm) directions and smaller with kV for the lateral directions (0.8 cm vs. 0.9 cm).

Conclusions

The chosen modality influences the setup error observed which will influence the correction applied. Allowing a better observation of the volumes of interest, CBCT should be the modality of choice in this pathology. The CTV–PTV margins could be shrunk if CBCT is used.  相似文献   

2.

Aim

To verify the reproducibility of patients irradiated after mastectomy on the immobilization system designed and manufactured for our hospital and to compare the Internal Protocol (IP) with the modified-No Action Level Protocol.

Background

Application of forward IMRT techniques requires a good reproducibility of patient positioning. To minimize the set-up error, an effective immobilization system is important.

Materials and methods

The study was performed for two groups of 65 each. In the first group, portal images for anterior field were taken in 1–3 fractions and, subsequently, three times a week. In this group, the mNAL protocol was used. In the second group, the IP was used. The portal images from the anterior field and from the gantry 0 were taken during the 1–3 and 10 fractions. In both groups, image registration was performed off-line. For each group the systematic and random errors and PTV margin were calculated.

Results

In the first group the value of the population systematic errors and random errors were 1.6 ± 1.6 mm for the left–right, and 1.5 ± 1.7 mm for the cranial–caudal directions, respectively, 1.7 ± 1.3 mm, and 1.9 ± 1.3 mm for the second group. The PTV margins for the left–right and cranial–caudal directions were 5.1 and 4.9 mm for the first group and 5.4 and 6.4 mm for the second group.

Conclusions

For patients immobilized with our support device treated according to the mNAL protocol or IP, a good set-up reproducibility was obtained. Implementation of IP limits the number of required images.  相似文献   

3.

Aim/Background

The analysis of systematic and random errors obtained from the pooled data on inter-fraction prostate motion during radiation therapy in two institutions.

Materials and methods

Data of 6085 observations for 216 prostate cancer patients treated on tomotherapy units in two institutions of position correction shifts obtained by co-registration of planning and daily CT studies were investigated. Three independent variables: patient position (supine or prone), target (prostate or prostate bed), and imaging mode (normal or coarse) were analyzed. Systematic and random errors were evaluated and used to calculate the margins for different options of referencing based on the position corrections observed with one, three, or five imaging sessions.

Results

Statistical analysis showed that only the difference between normal and coarse modes of imaging was significant, which allowed to merge the supine and prone position sub-groups as well as the prostate and prostate bed patients. In the normal and coarse imaging groups, the margins calculated using systematic and random errors in the medio-lateral and cranio-caudal directions (5.5 mm and 4.5 mm, respectively) were similar, but significantly different (5.3 mm for the normal mode and 7.1 mm for the coarse mode) in the anterio-posterior direction. The reference scheme based on the first three fractions (R3) was found to be the optimal one.

Conclusions

The R3 reference scheme effectively reduced systematic and random errors. Larger margins in the anterio-posterior direction should be used during prostate treatment on the tomotherapy unit, as coarse imaging mode is chosen in order to reduce imaging time and dose.  相似文献   

4.

Background

Late rectal injury is a common side effect of external beam radiotherapy for prostate cancer.

Aim

The aim of this study was to evaluate what total dose may be safely delivered for prostate patients for 3DCRT and IMRT techniques and the CTV–PTV margin.

Materials and methods

3DCRT and IMRT plans were prepared for 12 patients. For each patient PTV was defined with CTV–PTV margins of 0.4, 0.6, …, 1.0 cm, and total doses of 70, 72, …, 80 Gy, with 2 Gy dose fraction. NTCP values for the rectum were calculated using the Lyman model. Both techniques were compared in terms of population mean DVH.

Results

Significantly smaller NTCPs for IMRT were obtained. For both techniques diminishing the margin CTV–PTV of 2 mm leads to decreasing the NTCP of about 0.03. For total dose of 80 Gy the NTCP was smaller than 10% for the 4 mm margin only. The QUANTEC dose volume constraints were more frequently fulfilled for the IMRT technique than for the 3DCRT technique.

Conclusions

The IMRT technique is safer for prostate patients than the 3DCRT. If very high total doses are applied the CTV–PTV margin of 0.4 cm and the IMRT technique should be used. If the CTV–PTV margin of 0.6 cm is applied, the NTCP is smaller than 10% for the 3DCRT and IMRT techniques for the total doses smaller than 74 Gy and 78 Gy, respectively.  相似文献   

5.

Introduction

The accuracy of radiation delivery is increasingly important as radiotherapy technology continues to develop. The goal of this study was to evaluate intrafractional motion during intracranial radiosurgery and the relationship between motion change and treatment time.

Methods and Materials

A total of 50 treatment records with 5988 images, all acquired during treatments with the CyberKnife Radiosurgery System, were retrospectively analyzed in this study. We measured translation and rotation motion including superior-inferior (SI), right-left (RL), anterior-posterior (AP), roll, tilt and yaw. All of the data was obtained during the first 45 minutes of treatment. The records were divided into 3 groups based on 15-min time intervals following the beginning of treatment: group A (0-15 min), group B (16-30 min) and group C (31-45 min). The mean deviations, systematic errors, random errors and margin for planning target volume (PTV) were calculated for each group.

Results

The mean deviations were less than 0.1 mm in all three translation directions in the first 15 minutes. Greater motion occurred with longer treatment times, especially in the SI direction. For the 3D vector, a time-dependent change was observed, from 0.34 mm to 0.77 mm (p=0.01). There was no significant correlation between the treatment time and deviations in the AP, LR and rotation axes. Longer treatment times were associated with increases in systematic error, but not in random error. The estimated PTV margin for groups A, B and C were 0.86 / 1.14 / 1.31 mm, 0.75 / 1.12 / 1.20 mm, and 0.43 / 0.54 / 0.81 mm in the SI, RL, and AP directions, respectively.

Conclusions

During intracranial radiosurgery, a consistent increase in the positioning deviation over time was observed, especially in the SI direction. If treatment time is greater than 15 minutes, we recommend increasing the PTV margins to ensure treatment precision.  相似文献   

6.

Background

This study evaluated patterns of treatment failure (especially locoregional failure; LRF) after radical esophagectomy and proposes a clinical target volume (CTV) for postoperative radiotherapy (PORT) among patients with thoracic esophageal squamous cell carcinoma (SCC).

Methods

All patients who were followed up in our center after radical esophagectomy between 2007 and 2011 were retrospectively enrolled. The patterns of first discovered failure were assessed, and LRFs (including anastomotic and regional lymph node recurrences) were evaluated to determine whether our proposed PORT CTV encompassed these areas. The clinicopathologic factors predictive of lymphatic recurrence type were analyzed.

Results

Of the 414 patients who underwent surgery and were followed up over the study, 207 experienced recurrent or metastatic diseases. The median time to progression was 11.0 months. Of the 173 patients with locoregional recurrence, nodal failure recurred in 160; supraclavicular and superior mediastinal lymph nodes had the highest metastasis rates. All 233 recurrent sites across the 160 patients were located in a standard CTV area, including the bilateral supraclavicular areas, the entire mediastinum, and the left gastric lymphatic drainage region. A total of 203 sites (87.2%) were located in either the bilateral supraclavicular areas or the entire mediastinum, and 185 sites (79.4%) were located in either the bilateral supraclavicular areas or the upper mediastinum. A multivariate analysis revealed the lymph node metastatic ratio (LNMR) and tumor differentiation were risk factors for nodal failure.

Conclusions

Locoregional recurrence (especially lymph node recurrence) was the most common and potentially preventable type of initial treatment failure after curative surgery among patients with thoracic esophageal SCC. The proposed PORT CTV covered most LRF sites. The lymphatic drainage regions for PORT are selective, and the supraclavicular and superior mediastinal areas should be considered. However, the value of PORT and the extent of CTV should be investigated in further prospective studies.  相似文献   

7.

Aim

To identify the most reproducible technique of patient positioning and immobilization during pelvic radiotherapy.

Background

Radiotherapy plays an important role in the treatment of pelvic malignancies. Errors in positioning of patient are an integral component of treatment. The present study compares two methods of immobilization with no immobilization with an aim of identifying the most reproducible method.

Materials and methods

65 consecutive patients receiving pelvic external beam radiotherapy were retrospectively analyzed. 30, 21 and 14 patients were treated with no-immobilization with a leg separator, whole body vacuum bag cushion (VBC) and six point aquaplast immobilization system, respectively. The systematic error, random error and the planning target volume (PTV) margins were calculated for all the three techniques and statistically analyzed.

Results

The systematic errors were the highest in the VBC and random errors were the highest in the aquaplast group. Both systematic and random errors were the lowest in patients treated with no-immobilization. 3D Systematic error (mm, mean ± 1SD) was 4.31 ± 3.84, 3.39 ± 1.71 and 2.42 ± 0.97 for VBC, aquaplast and no-immobilization, respectively. 3D random error (mm, 1SD) was 2.96, 3.59 and 1.39 for VBC, aquaplast and no-immobilization, respectively. The differences were statistically significant between all the three groups. The calculated PTV margins were the smallest for the no-immobilization technique with 4.56, 4.69 and 4.59 mm, respectively, in x, y and z axes, respectively.

Conclusions

Among the three techniques, no-immobilization technique with leg separator was the most reproducible technique with the smallest PTV margins. For obvious reasons, this technique is the least time consuming and most economically viable in developing countries.  相似文献   

8.
9.

Aim

The purpose of this study was to examine the usefulness of using Simultaneous Integrated Boost (SIB) radiotherapy for thyroid cancer treatment.

Background

At our hospital a 3D Conformal RadioTherapy (3D-CRT) technique involving photon and electron beams for the treatment of thyroid cancer was often used.1 High dose to the spinal canal was limiting the total dose of such a treatment. After investigation of Intensity Modulated Radiotherapy (IMRT) technique involving seven photon beams for first course of treatment3 we decided to examine possibility of reducing treatment fractions by using SIB radiotherapy.

Material and methods

Plans for 10 patients were studied. For each patient, IMRT plan for the first course of treatment (50 Gy for PTV), two plans for the second course of treatment (10 Gy for BOOST) and a SIB plan (50 Gy for PTV, 56 Gy for BOOST) were prepared. For all plans, comparisons of dose statistics for the PTV, BOOST, PTV without BOOST (defined as PTV without BOOST with 1 cm margin), spinal canal and Patient Outline (Body) was done.

Results

Minimum dose for BOOST is higher in the SIB technique than in the two course treatment. PTV without BOOST receives the same average dose in SIB and the 1st course IMRT – 50.10 Gy and 49.84 Gy, respectively. In the SIB technique, higher reduction of dose delivered to the spinal canal is possible (27 Gy compared with 30 Gy).

Conclusion

SIB therapy for thyroid cancer with relation to typical two course treatment is a good proposal of reducing the number of fractions with the same dose for BOOST and PTV without BOOST. Additionally, better sparing of the spinal canal is achieved.  相似文献   

10.

Background and Aims

Red or purple coloration of leaf margins is common in angiosperms, and is found in approx. 25 % of New Zealand Veronica species. However, the functional significance of margin coloration is unknown. We hypothesized that anthocyanins in leaf margins correspond with increased phenolic content in leaf margins and/or the leaf entire, signalling low palatability or leaf quality to edge-feeding insects.

Methods

Five species of Veronica with red leaf margins, and six species without, were examined in a common garden. Phenolic content in leaf margins and interior lamina regions of juvenile and fully expanded leaves was quantified using the Folin–Ciocalteu assay. Proportions of leaf margins eaten and average lengths of continuous bites were used as a proxy for palatability.

Key Results

Phenolic content was consistently higher in leaf margins compared with leaf interiors in all species; however, neither leaf margins nor more interior tissues differed significantly in phenolic content with respects to margin colour. Mean phenolic content was inversely correlated with the mean length of continuous bites, suggesting effective deterrence of grazing. However, there was no difference in herbivore consumption of red and green margins, and the plant species with the longest continuous grazing patterns were both red-margined.

Conclusions

Red margin coloration was not an accurate indicator of total phenolic content in leaf margins or interior lamina tissue in New Zealand Veronica. Red coloration was also ineffective in deterring herbivory on the leaf margin, though studies controlling for variations in leaf structure and biochemistry (e.g. intra-specific studies) are needed before more precise conclusions can be drawn. It is also recommended that future studies focus on the relationship between anthocyanin and specific defence compounds (rather than general phenolic pools), and evaluate possible alternative functions of red margins in leaves (e.g. antioxidants, osmotic adjustment).  相似文献   

11.

Aim

This study compared the dosimetric impact between prostate IMRT and VMAT due to patient''s weight loss.

Background

Dosimetric variation due to change of patient''s body contour is difficult to predict in prostate IMRT and VMAT, since a large number of small and irregular segmental fields is used in the delivery.

Materials and methods

Five patients with prostate volumes ranging from 32.0 to 86.5 cm3 and a heterogeneous pelvis phantom were used for prostate IMRT and VMAT plans using the same set of dose–volume constraints. Doses in IMRT and VMAT plans were recalculated with the patient''s and phantom''s body contour reduced by 0.5–2 cm to mimic size reduction. Dose coverage/criteria of the PTV and CTV and critical organs (rectum, bladder and femoral heads) were compared between IMRT and VMAT.

Results

In IMRT plans, increases of the D99% for the PTV and CTV were equal to 4.0 ± 0.1% per cm of reduced depth, which were higher than those in VMAT plans (2.7 ± 0.24% per cm). Moreover, increases of the D30% of the rectum and bladder per reduced depth in IMRT plans (4.0 ± 0.2% per cm and 3.5 ± 0.5% per cm) were higher than those of VMAT (2.2 ± 0.2% per cm and 2.0 ± 0.6% per cm). This was also true for the increase of the D5% for the right femoral head in a patient or phantom with size reduction due to weight loss.

Conclusions

VMAT would be preferred to IMRT in prostate radiotherapy, when a patient has potential to suffer from weight loss during the treatment.  相似文献   

12.

Objective

To investigate the difference between preoperative radiologic tumor volume (RTV) and postoperative pathologic tumor volume (PTV) in patients who received nephrectomy for renal cell carcinoma (RCC).

Materials and Methods

We reviewed 482 patients who underwent preoperative computed tomography (CT) within 4 weeks before radical or partial nephrectomy for renal cell carcinoma. RTV measured by a three dimensional rendering program was compared with PTV (π/6ⅹheightⅹlengthⅹwidth) measured in surgical specimen according to pathologic tumor size and histologic subtype. Correlation of the inter-quartile range (IQR) of the RTV and Fuhrman nuclear grade was also investigated.

Results

There was a significant positive linear correlation between RTV and PTV (p<0.001, r = 0.911), and the mean RTV and mean PTV were not significantly different (79.0 vs 76.9cm3, p = 0.393). For pathologic tumor size (PTS) <4cm, the mean RTV was larger than the mean PTV (10.9 vs 7.1cm3, p<0.001). For a PTS of 4-7cm, the mean RTV was larger than the mean PTV (56.0 vs 44.7cm3, p<0.001). However, for a PTS ≥7cm, there was no statistical difference between RTV and PTV (p>0.05). Among patients with clear cell RCC, the mean RTV was significantly larger than the mean PTV (p = 0.042), not for non-clear cell group (p = 0.055). As the quartile of the RTV increased, the Fuhrman grade also increased (p<0.001).

Conclusions

RTV was correlated with PTV and pathologic grade. RTV was larger than the PTV for a tumor size 7 cm or less or in clear cell RCC. RTV may be useful to measure tumor burden preoperatively.  相似文献   

13.

Background

The exact assessment of a tonsil carcinoma''s size is often difficult because of the tumour''s submucosal extension and deep infiltration.

Aim

The aim of the study is to assess the usefulness of intraoperative ultrasonography in tonsil cancer.

Material

Twenty patients with carcinoma of the tonsil were included in the study (squamous cell carcinoma keratosis – 12, squamous cell carcinoma akeratosis – 6, diffuse large B cell lymphoma – 1, neoplasma malignum microcellulare – 1).

Method

Transcutaneous, endoscopic, and intraoperative ultrasonography were performed using a linear 7.5 MHz probe.

Results

The difference in the results was statistically significant between palpation examination and intraoperative ultrasonographic examination, between transcutaneous ultrasonographic examination and intraoperative ultrasonographic examination, and between endoscopic ultrasonographic examination and intraoperative ultrasonographic examination in tonsil tumours. Generally, tumour size assessed by intraoperative ultrasonography was more advanced than those assessed by other methods.

Conclusions

Intraoperative ultrasonography is a safe, non-invasive method, which can be repeated at every stage of surgery. There were no contraindications or side effects. In all cases histological margins corresponded to sonographic margins. Intraoperative ultrasonography provides a quick and reliable orientation during resection of tonsil carcinoma.  相似文献   

14.

Aim

To investigate the clinical application of a technique for patient set-up verification in breast cancer radiotherapy based on a 3D surface image registration system.

Background

Accurate and reproducible patient set-up is a prerequisite to correctly deliver fractionated radiotherapy. Various approaches are available to verify and correct patient setup for 3D image acquisition in a radiation treatment room.

Materials and methods

The study analyzed the setup reproducibility of 15 patients affected by breast cancer and candidates for conformal radiotherapy by using the AlignRT system (VisionRT, London, UK). At the initial setup, electronic portal imaging device (EPID) images were compared with Digitally Reconstructed Radiographs (DRRs) and a reference three-dimensional (3D) surface image was obtained by AlignRT. Surface images were acquired prior to every subsequent setup procedure. The systematic and random errors along longitudinal and vertical directions were measured and compared for the two systems.

Results

The procedure for surface registration, image acquisition and comparison with the reference image took less than 1 min on average. The T test for systematic error showed no significant difference between the 2 verification systems along the longitudinal (p = 0.69) and vertical (p = 0.67) axes. The T-test for random error showed a significant difference between the 2 systems along the vertical axis (p = 0.05).

Conclusion

AlignRT is fast, simple, non-invasive and seems to be reliable in detecting patient setup errors. Our results suggest that it could be used to assess the setup reproducibility for breast cancer patients.  相似文献   

15.

Aim

This prospective study aims to assess feasibility of helical tomotherapy (HT) for craniospinal irradiation (CSI) and perform dosimetric comparison of treatment plans for both HT and 3D conformal radiotherapy (3DCRT).

Background

CSI is a challenging procedure. Large PTV size requires field matching due to technical limitations of standard linear accelerators, which cannot irradiate such volumes as a single field. HT could help to avoid these limitations as irradiation of long fields is possible without field matching.

Materials and methods

Three adults were enrolled from 2009 to 2010. All patients received radiochemotherapy. Treatment plans in prone position for 3DCRT and in supine position for HT were generated. The superior plan was used for patients’ irradiation. Plans were compared with the application of DVH, Dx parameters – where x represents a percentage of the structure volume receiving a normalized dose and homogeneity index (HI).

Results

All patients received HT irradiation. The treatment was well tolerated. The HT plans resulted in a better dose coverage and uniformity in the PTV: HI were 5.4, 7.8, 6.8 for HT vs. 10.3, 6.6, 10.4 for 3DCRT. For most organs at risk (OARs), the D(V80) was higher for HT than for 3DCRT, whereas D(V5) was lower for HT.

Conclusions

HT is feasible for CSI, and in comparison with 3DCRT it improves PTV coverage. HT reduces high dose volumes of OARs, but larger volumes of normal tissue receive low radiation dose. HT requires further study to establish correlations between dosimetrical findings and clinical outcomes, especially with regard to late sequelae of treatment.  相似文献   

16.

Purpose

To develop a robust tool for quantitative in situ pathology that allows visualization of heterogeneous tissue morphology and segmentation and quantification of image features.

Materials and Methods

Tissue excised from a genetically engineered mouse model of sarcoma was imaged using a subcellular resolution microendoscope after topical application of a fluorescent anatomical contrast agent: acriflavine. An algorithm based on sparse component analysis (SCA) and the circle transform (CT) was developed for image segmentation and quantification of distinct tissue types. The accuracy of our approach was quantified through simulations of tumor and muscle images. Specifically, tumor, muscle, and tumor+muscle tissue images were simulated because these tissue types were most commonly observed in sarcoma margins. Simulations were based on tissue characteristics observed in pathology slides. The potential clinical utility of our approach was evaluated by imaging excised margins and the tumor bed in a cohort of mice after surgical resection of sarcoma.

Results

Simulation experiments revealed that SCA+CT achieved the lowest errors for larger nuclear sizes and for higher contrast ratios (nuclei intensity/background intensity). For imaging of tumor margins, SCA+CT effectively isolated nuclei from tumor, muscle, adipose, and tumor+muscle tissue types. Differences in density were correctly identified with SCA+CT in a cohort of ex vivo and in vivo images, thus illustrating the diagnostic potential of our approach.

Conclusion

The combination of a subcellular-resolution microendoscope, acriflavine staining, and SCA+CT can be used to accurately isolate nuclei and quantify their density in anatomical images of heterogeneous tissue.  相似文献   

17.

Objective

To quantify the impact of antiretroviral therapy (ART) on mortality in HIV-positive people during tuberculosis (TB) treatment.

Design

We conducted a systematic literature review and meta-analysis. Studies published from 1996 through February 15, 2013, were identified by searching electronic resources (Pubmed and Embase) and conference books, manual searches of references, and expert consultation. Pooled estimates for the outcome of interest were acquired using random effects meta-analysis.

Subjects

The study population included individuals receiving ART before or during TB treatment.

Main Outcome Measures

Main outcome measures were: (i) TB-case fatality ratio (CFR), defined as the proportion of individuals dying during TB treatment and, if mortality in HIV-positive people not on ART was also reported, (ii) the relative risk of death during TB treatment by ART status.

Results

Twenty-one studies were included in the systematic review. Random effects pooled meta-analysis estimated the CFR between 8% and 14% (pooled estimate 11%). Among HIV-positive TB cases, those receiving ART had a reduction in mortality during TB treatment of between 44% and 71% (RR = 0.42, 95%CI: 0.29–0.56).

Conclusion

Starting ART before or during TB therapy reduces the risk of death during TB treatment by around three-fifths in clinical settings. National programmes should continue to expand coverage of ART for HIV positive in order to control the dual epidemic.  相似文献   

18.

Background

Major depressive disorder afflicts an estimated 17% of individuals during their lifetimes at tremendous suffering and costs. Interpersonal psychotherapy and other psychodynamic therapies may be effective interventions for major depressive disorder, but the effects have only had limited assessment in systematic reviews.

Methods/Principal Findings

Cochrane systematic review methodology with meta-analysis and trial sequential analysis of randomized trials comparing the effect of psychodynamic therapies versus ‘treatment as usual’ for major depressive disorder. To be included the participants had to be older than 17 years with a primary diagnosis of major depressive disorder. Altogether, we included six trials randomizing a total of 648 participants. Five trials assessed ‘interpersonal psychotherapy’ and only one trial assessed ‘psychodynamic psychotherapy’. All six trials had high risk of bias. Meta-analysis on all six trials showed that the psychodynamic interventions significantly reduced depressive symptoms on the 17-item Hamilton Rating Scale for Depression (mean difference −3.12 (95% confidence interval −4.39 to −1.86;P<0.00001), no heterogeneity) compared with ‘treatment as usual’. Trial sequential analysis confirmed this result.

Discussion

We did not find convincing evidence supporting or refuting the effect of interpersonal psychotherapy or psychodynamic therapy compared with ‘treatment as usual’ for patients with major depressive disorder. The potential beneficial effect seems small and effects on major outcomes are unknown. Randomized trials with low risk of systematic errors and low risk of random errors are needed.  相似文献   

19.

Aim

To study the use of RapidArc techniques in the treatment of prostate cancer patients with hip prosthesis.

Background

An important aspect of treatment planning is to achieve dose homogeneity inside the planning target volume (PTV). Especially for those patients presenting with hip prosthesis, it becomes a challenging task to achieve dose uniformity inside the PTV.

Materials and methods

Five prostate patients presenting with hip prosthesis who had undergone radical radiotherapy were selected for this study. Depending on the composition of prosthesis, a predefined set of Hounsfield values were assigned to each study set. RapidArc plans were generated on an Eclipse treatment planning system. Two arcs that include clockwise and counter-clockwise arcs were used in all these cases. To avoid beams passing through the prosthesis, a simple structure was defined around it with 1 cm margin and a strict dose constraint applied to the block during VMAT optimization.

Results

The mean D2/D98 ratio of PTV for all the patients was 1.06 ± 0.01. The mean percentage rectum volume receiving 50 Gy, 60 Gy, 70 Gy and 75 Gy for all the patients were 33.1 ± 5.9, 21.7 ± 5.5, 13.8 ± 4.4 and 9.5 ± 3.0, respectively.

Conclusions

This study shows that using a double arc RapidArc technique is a simple and effective treatment method of treating prostate cancer in patients presenting with a hip prosthesis. The definition of a beam avoidance structure encompassing the prosthesis and applying strict dose constraints to it reduces the beam contribution to the prosthesis  相似文献   

20.

Object

Fluorescence imaging has the potential to significantly improve neurosurgical resection of oncologic lesions through improved differentiation between normal and cancerous tissue at the tumor margins. In order to successfully mark glioma tissue a fluorescent tracer must have the ability to penetrate through the blood brain barrier (BBB) and provide delineation in the tumor periphery where heterogeneously intact BBB may exist. In this study it was hypothesized that, due to its smaller size, fluorescently labeled anti-EGFR Affibody protein (∼7 kDa) would provide a more clear delineation of the tumor margin than would fluorescently labeled cetuximab, a full antibody (∼150 kDa) to the epidermal growth factor receptor (EGFR).

Methods

Cetuximab and anti-EGFR targeted Affibody were conjugated to two different fluorescent dyes (both emitting in the near-infrared) and injected intravenously into 6 athymic mice which were inoculated orthotopically with green fluorescent protein (GFP) expressing human U251 glioma cells. Each mouse was sacrificed at 1-h post injection, at which time brains were removed, snap frozen, sectioned and quantitatively analyzed for fluorescence distribution.

Results

Ex vivo analysis showed on average, nearly equal concentrations of cetuximab and Affibody within the tumor (on average Affibody made up 49±6% of injected protein), however, the cetuximab was more confined to the center of the tumor with Affibody showing significantly higher concentrations at the tumor periphery (on average Affibody made up 72±15% of injected protein in the outer 50 um of the tumor). Further ex vivo analysis of detection studies showed that the Affibody provided superior discrimination for differentiation of tumor from surrounding normal brain.

Conclusions

The present study indicates that fluorescently labeled anti-EGFR Affibody can provide significantly better delineation of tumor margins than a fluorescently labeled anti-EGFR antibody and shows considerable potential for guiding margin detection during neurosurgery.  相似文献   