首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Halothane (CF3CHClBr), a widely used volatile anesthetic, undergoes extensive biotransformation in humans. Oxidative halothane metabolism yields the stable metabolites trifluoroacetic acid and bromide which can be detected in plasma and urine. To date, analytical methodologies have either required extensive sample preparation, or two separate analytical procedures to determine plasma and urine concentrations of these analytes. A rapid and sensitive method utilizing high-performance liquid chromatography-ion chromatography (HPLC-IC) with suppressed conductivity detection was developed for the simultaneous detection of both trifluoroacetic acid and bromide in plasma and urine. Sample preparation required only ultrafiltration. Standard curves were linear (r2≥0.99) from 10 to 250 μM trifluoroacetic acid and 2 to 5000 μM bromide in plasma and 10 to 250 μM trifluoroacetic acid and 2 to 50 μM bromide in urine. The assay was applied to quantification of trifluoroacetic acid and bromide in plasma and urine of a patient undergoing halothane anesthesia.  相似文献   

2.
A liquid chromatographic method is described for the simultaneous determination of cefalexin and trimethoprim in dog plasma. A simple protein precipitation procedure was adopted for the sample preparation with satisfactory extraction recoveries for both analytes. Chromatographic separation of the analytes was achieved on a C(18) column using a mixture of 2 mol/l formate buffer (pH 3.5), methanol and acetonitrile (22:7:7, v/v/v) containing a 0.002 mol/l sodium dodecyl sulfate as mobile phase and detection was performed at 240 nm. The linearity was obtained over the concentration ranges of 1.0-100.0 microg/ml for cefalexin and 0.5-50.0 microg/ml for trimethoprim. For each level of QC samples including the lower limit of quantification, both inter- and intra-day precisions (R.S.D.) were < or =14.0% for cefalexin and < or =11.4% for trimethoprim, and accuracy (RE) was -1.4% for cefalexin and -3.0% for trimethoprim. The present LC method was successfully applied to the pharmacokinetic studies of coformulated cefalexin dispersible tablets after oral administration to beagle dogs.  相似文献   

3.
For the quantification of nitrite and nitrate, the stable metabolites of -arginine-derived nitric oxide (NO) in human urine and plasma, we developed a gas chromatographic—mass spectrometric (GC—MS) method in which [15N]nitrite and [15N]nitrate were used as internal standards. Endogenous nitrite and [15N]nitrite added to acetone-treated plasma and urine samples were converted into their pentafluorobenzyl (PFB) derivatives using PFB bromide as the alkylating agent. For the analysis of endogenous nitrate and [15N]nitrate they were reduced to nitrite and [15N]nitrite, respectively, by cadmium in acidified plasma and urine samples prior to PFB alkylation. Reaction products were extracted with toluene and 1-μl aliquots were analyzed by selected-ion monitoring at m/z 46 for endogenous nitrite (nitrate) and m/z 47 for [15N]nitrite ([15N]nitrate). The intra- and inter-assay relative standard deviations for the determination of nitrite and nitrate in urine and plasma were below 3.8%. The detection limit of the method was 22 fmol of nitrite. Healthy subjects (n = 12) excreted into urine 0.49 ± 0.25 of nitrite and 109.5 ± 61.7 of nitrate (mean ± S.D., μmol/mmol creatinine) with a mean 24-h output of 5.7 μmol for nitrite and 1226 μmol for nitrate. The concentrations of nitrite and nitrate in the plasma of these volunteers were determined to be (mean ± S.D., μmol/l) 3.6 ± 0.8 and 68 ± 17, respectively.  相似文献   

4.
Three phase liquid phase microextraction (three phase LPME) technique coupled with HPLC-UV has been applied as a sensitive and efficient sample preparation method to determine phenylacetic acid (PAA) as a biomarker of depressive disorders and phenylpropionic acid (PPA) in biological fluids. The compounds were extracted from 3.0 ml aqueous solution with the adjustment of pH at a fixed value in the range of 2.0-3.5 (donor solution) into an organic phase (1-hexanol) layered on the surface of the donor solution and finally back-extracted into 4.0 microl of the acceptor microdrop (pH 11.1) located at the end of the microsyringe needle. After a prescribed back-extraction time, the acceptor microdrop was withdrawn into the microsyringe and then directly injected into the HPLC system. In order to achieve maximum extraction efficiency, different parameters affecting the extraction conditions were optimized. At the optimum conditions (donor solution: 2.3M Na(2)SO(4), pH 2.0-3.5; organic membrane: 95 microl of 1-hexanol; acceptor solution: 4.0 microl of 0.1M NH(3)/NH(4)(+) with pH 11.1; donor solution temperature: 45-50 degrees C; extraction time: 20 min and back-extraction time: 12 min), up to 110-fold enrichment factor was obtained. The calibration curve for these analytes was linear in the range of 1-5000 microg/l with r(2)>0.998. The intraday and interday RSD% were below 6.5% and the limits of detection (LODs) for both analytes were 0.2 microg/l (based on S/N=3). The proposed technique is a low cost, simple and sensitive method with highly clean-up effect. Finally, this technique was successfully utilized for the detection of target analytes in human urine, serum and plasma.  相似文献   

5.
A new, accurate, fast and simple method has been implemented by which nitrite and nitrate ions, as stable forms of nitric oxide production were studied. A study of these two ions was carried out by a sensitive and accurate HPLC method with two detectors. The most important advantages of the reported method are: short time of analysis, minimal sample pre-treatment, long life of the analytical column and stable eluent solution. The photodiode array UV-Vis detector detected nitrite and nitrate ions at an absorbance of 212 nm. Much more sensitive electrochemical detection with a WE (glassy carbon) electrode was used for the detection of nitrite ions. An analytical chromatographic column was formed by a sorbent, containing strong base anion-exchange groups bound in Cl(-) form in the hydrophilic hydroxyethyl methacrylate matrix. The anions were analysed in human plasma without deproteinization using 0.02 M sodium perchlorate monohydrate as eluent solution at pH 3.9. At this pH organic substances do not affect the analysis. The retention times for nitrite and nitrate were 3.62 and 3.72 min (by electrochemical detection) and 4.44 min, respectively. The method was linear (r=0.9992, 0.9998, 0.996) within a 1-100 (nitrate), 1-20 micro mol/l (nitrite) concentration range.  相似文献   

6.
This work presents a cloud-point extraction process using the micelle-mediated extraction method for simultaneous preconcentration and determination of Sb(III) and Sb(V) species in biological and environmental samples as a prior preconcentration step to their spectrophotometric determination. The analytical system is based on the selective reaction between Sb(III) and 3-dichloro-6-(3-carboxy-2-hydroxy-1-naphthylazo)quinoxaline (DCHNAQ) in the presence of cetyltrimethylammonium bromide (CTAB) and potassium iodide at pH 4.5. Total Sb concentration was determined after reduction of Sb(V) to Sb(III) in the presence of potassium iodide and ascorbic acid. The optimal reaction conditions and extraction were studied, and the analytical characteristics of the method (e.g., limits of detection and quantification, linear range, preconcentration, improvement factors) were obtained. Linearity for Sb(III) was obeyed in the range of 0.2–20 ng ml−1. The detection and quantification limits for the determination of Sb(III) were 0.055 and 0.185 ng ml−1, respectively. The method has a lower detection limit and wider linear range, inexpensive instrument, and low cost, and is more sensitive compared with most other methods. The interference effect of some anions and cations was also studied. The method was applied to the determination of Sb(III) in the presence of Sb(V) and total antimony in blood plasma, urine, biological, and water samples.  相似文献   

7.
The analytical method described permits the determination of 2-dimethylamino-5,6-dimethyl-4-hydroxypyrimidine (DDHP), 2-methylamino-5,6-dimethyl-4-hydroxypyrimidine (MDHP) and 2-amino-5,6-dimethyl-4-hydroxypyrimidine (ADHP) in human urine. These hydroxypyrimidines are metabolites of pirimicarb (2-dimethylamino-5,6-dimethylpyrimidin-4-yldimethylcarbamate) which is applied as insecticide. The analytes are extracted into a mixture of diethyl ether and acetonitrile. Pentafluorobenzyl bromide serves as derivatising reagent. The derivatives are analysed using capillary gas chromatography with mass selective detection. 2-Amino-4-hydroxy-6-methylpyrimidine and 4-hydroxy-6-trifluoromethylpyrimidine are used as internal standards. The detection limits are 0.5 μg/l (DDHP), 1 μg/l (MDHP) and 4 μg/l (ADHP), respectively. The method was used for analysing seven urine samples collected from workers who had applied pirimicarb. The three metabolites were found in every sample in concentrations up to 60 μg/l.  相似文献   

8.
We have developed and validated a new, reliable and very sensitive method for the determination of the urinary metabolites of the most common pyrethroids in one analytical run. After acidic hydrolysis for the cleavage of conjugates, the analytes cis-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (cis-Cl(2)CA), trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (trans-Cl(2)CA), cis-3-(2,2-dibromovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (Br(2)CA), 4-fluoro-3-phenoxybenzoic acid (F-PBA) and 3-phenoxybenzoic acid (3-PBA) were extracted from the matrix with a liquid-liquid extraction procedure using n-hexane under acidic conditions. For further clean-up, NaOH was added to the organic phase and the carboxylic acids were re-extracted into the aqueous phase. After acidification and extraction into n-hexane again, the metabolites were then derivatised to volatile esters using N-tert.-butyldimethylsilyl-N-methyltrifluoroacetamid (MTBSTFA). Separation and detection were carried out using capillary gas chromatography with mass-selective detection (GC-MS). 2-Phenoxybenzoic acid (2-PBA) served as internal standard for the quantification of the pyrethroid metabolites. The limit of detection for all analytes was 0.05 microg/l urine. The RSD of the within-series imprecision was between 2.0 and 5.4% at a spiked concentration of 0.4 microg/l and the relative recovery was between 79.3 and 93.4%, depending on the analyte. This method was used for the analysis of urine samples of 46 persons from the general population without known exposure to pyrethroids. The metabolites cis-Cl(2)CA, trans-Cl(2)CA and 3-PBA could be found in 52, 72 and 70% of all samples with median values of 0.06, 0.11 and 0.16 microg/l, respectively. Br(2)CA and F-PBA could also be detected in 13 and 4% of the urine samples.  相似文献   

9.
A method for the quantification of five congener ephedrines in urine samples without sample preparation was developed. The analytes were trapped on a C18 precolumn and separated on a C18 BDS analytical column. Baseline separation was achieved for all analytes. The method meets the requirements of the International Olympic Committee (IOC) medical commission regarding cut-off limits for positive doping cases with ephedrines.  相似文献   

10.
Capillary electrophoresis methods are described for the analysis of the major inorganic anions (nitrite, nitrate, chloride, sulphate, phosphate), organic acids (oxalate, malate, citrate, succinate) and inorganic cations (ammonium, potassium, sodium, calcium, magnesium) in leaf extracts. Analytical performance was validated for extracts from leaves of four sclerophyllous species: Eucalyptus globulus, E. cladocalyx, E. nitens and Pinus radiata. Inorganic anions and organic acids were analysed in a single run within 5 min using a background electrolyte of 2,6-pyridinedicarboxylic acid (20 mM) and cetyltrimethylammonium bromide (0.5 mM). Cations were analysed in a separate run also within 5 min using imidazole (10 mM) and 18-crown-6 (2 mM) as background electrolyte. Replicate injections were highly repeatable when the capillary was rinsed between runs with hydrochloric acid (0.25 M) and background electrolyte, but not when the acid rinse was omitted or replaced by a rinse with sodium hydroxide (0.25 M). Standard curves for all analytes were linear over the range of 0.05-1 mm. Standard curves constructed by serial dilution of a leaf extract were also highly linear, and this, combined with the excellent recovery of added solutes in a spike and recovery test, suggests quantification was unaffected by the complex matrix that is present in un-purified, hot water extracts of leaves. There were significant differences in concentrations of the major anions and cations between the species studied.  相似文献   

11.
A sensitive and highly automated high-performance liquid chromatography (HPLC) column-switching method has been developed for the simultaneous determination of the active metabolite III and its prodrug II, both derivatives of the oral platelet inhibitor Ro 48-3657 (I), in plasma and urine of man and dog. Plasma samples were deproteinated with perchloric acid (0.5 M), while urine samples could be processed directly after dilution with phosphate buffer. The prepared samples were injected onto a pre-column of a HPLC column switching system. Polar plasma or urine components were removed by flushing the precolumn with phosphate buffer (0.1 M, pH 3.5). Retained compounds (including II and III) were backflushed onto the analytical column, separated by gradient elution and detected by means of UV detection at 240 nm. The limit of quantification for both compounds was 1 ng/ml (500 μl of plasma) and 25 ng/ml (50 μl of urine) for plasma and urine, respectively. The practicability of the new method was demonstrated by the analysis of about 6000 plasma and 1300 urine samples from various toxicokinetic studies in dogs and phase 1 studies in man.  相似文献   

12.
In the present work, a method was developed and optimized aiming to determinate the herbicides paraquat (PQ) and diquat (DQ) in human plasma and urine samples. An initial procedure of chemical reduction of the analytes by adding NaBH4 directly in the buffered samples (pH 8.0) was performed. This procedure was necessary to convert the quaternary ammonium substances into more volatile compounds for gas chromatographic analysis. The reduction compounds were extracted with C18 cartridges (solid-phase extraction). Ethyl paraquat (EPQ) was used as internal standard (IS). Gas chromatography-mass spectrometry (GC-MS) was used to identify and quantify the analytes in selected ion monitoring (SIM) mode. The limits of detection were 0.05 mg/l for both PQ and DQ. By using the weighted least squares linear regression (1/x1/2 for plasma and 1/y for urine), the accuracy of the analytical method was improved at the lower end of the calibration curve (from 0.1 to 50 mg/l; r>0.98). This method can be readily utilized as an important tool to confirm the suspicion of PQ and/or DQ poisoning and evaluate the extent of the intoxication.  相似文献   

13.
Nitrite and nitrate levels in physiological fluids are commonly used as an index of nitric oxide production. We developed simple and rapid method for the determination of these anions by capillary zone electrophoresis employing borate buffer (pH 10, 100 mmol/l) as running electrolyte. The anions were analyzed in plasma and cerebrospinal fluid (CSF) without deproteinization of the samples. Electrophoresis was carried out in a capillary (36.5 cm×75 μm) at a potential of 15 kV, with on-column UV detection at 214 nm. Mean retention times for nitrite and nitrates were 4.631 and 5.152 min, respectively. The method was linear (r=0.999) within a 1–500 μmol/l concentration range. Physiological levels of nitrate in plasma (40.2 μmol/l) and CSF (15.3 μmol/l) could be determined with good precision (coefficients of variation <6%) and accuracy (recoveries of added nitrate to plasma and CSF were 97.4 and 104.5%, respectively). Measurements of the physiological levels of nitrite in plasma (6.1 μmol/l) and CSF (0.9 μmol/l) were less precise and accurate.  相似文献   

14.
A newly developed method permits the simultaneous quantitative determination of various aromatic amines (or metabolites of aromatic nitro compounds, respectively) in human urine in one analytical run. Applying this method it is possible to determine aniline, toluidines, 4-isopropylaniline, o-anisidine, 3- and 4-chloroaniline, 4-bromoaniline, aminonitrotoluenes, aminodinitrotoluenes, 3,5- and 3,4-dichloroaniline, alpha- and beta-naphtylamine and 4-aminodiphenyl. After separation from the urinary matrix by a simple liquid-liquid extraction at pH 6.2-6.4 the analytes are converted into their pentafluoropropionic acid amides. Separation and quantitative analysis is carried out by capillary gas chromatography and mass-selective detection in the single ion monitoring mode. The limits of detection were within the range from 0.05 microg/l (4-aminobiphenyl, o-anisidine, 3,5-dichloroaniline) to 2 microg/l urine (4-amino-2,6-dinitrotoluene). The relative standard deviation of the within-series imprecision (determined at spiked concentrations of 2.0 microg/l and 10 microg/l) was between 2.9 and 13.6% depending on analyte and concentration. The relative recovery rates were in the range of 70-121%. The analytes that do not contain a nitro function showed better performance regarding the analytical reliability criteria. In order to determine the suitability of this new method for biological monitoring we analysed 20 12-h urine samples of persons without known exposure to aromatic amines, nitroaromatics or precursors in a pilot study. In these samples various aromatic amines could be clearly identified. The general population renally excretes aniline (median: 3.5 microg/l; 95th percentile: 7.9 microg/l), o- (0.12 microg/l; 2.7 microg/l), m- (0.17 microg/l; 2.2 microg/l) and p-toluidine (0.11 microg/l; 0.43 microg/l), and o-anisidine (0.22 microg/l; 0.68 microg/l). Additionally, we found that the persons investigated also excrete 3- (<0.05 microg/l; 0.55 microg/l) and 4-chloroaniline (0.11 microg/l; 0.57 microg/l) as well as 3,5-dichloroaniline (0.18 microg/l; 1.5 microg/l). 3,4-Dichloroaniline was found in some specimens (20%) in concentrations near the limit of detection (<0.05 microg/l; 0.12 microg/l). We did not detect alpha- or beta-naphtylamine, 4-aminobiphenyl or metabolites of explosives in the samples.  相似文献   

15.
We developed a new 3-D HPLC method for on-line clean-up and simultaneous quantification of two important naphthalene metabolites, 1-naphthol and 2-naphthol, in human urine. Except an enzymatic hydrolysis no further sample pre-treatment is necessary. The metabolites are stripped from urinary matrix by on-line extraction on a restricted access material pre-column (RAM RP-8), transferred in backflush mode onto a silica-based CN-(cyano)phase column for further purification from interfering substances. By another successive column switching step both analytes are transferred with a minimum of overlapping interferences onto a C12 bonded reversed phase column with trimethylsilyl endcapping where the final separation is carried out. The entire arrangement is software controlled. Eluting analytes are quantified by fluorescence detection (227/430 nm) after an external calibration. Within a total run time of 40 min we can selectively quantify both naphthols with detection limits in the lower ppb range (1.5 and 0.5 microg/l for 1- and 2-naphthol, respectively) with excellent reliability (ensured by precision, accuracy, matrix-independency and FIOH quality assurance program participation). First results on a collective of 53 occupationally non exposed subjects showed mean levels of 11.0 microg/l (1-naphthol) and 12.9 microg/l (2-naphthol). Among smokers (n=21) a significantly elevated mean level of urinary naphthols was determined (1-naphthol: 19.2 microg/l and 2-naphthol: 23.7 microg/l) in comparison to non smokers (n=32; 1-naphthol: 5.6 microg/l, 2-naphthol: 5.6 microg/l).  相似文献   

16.
Capillary zone electrophoresis was employed for the determination of midecamycin using an end-column amperometric detection with a carbon fiber micro-disk bundle electrode at a constant potential of +1.15 V vs. saturated calomel electrode. The optimum conditions of separation and detection are 1.00x10(-3) mol l(-1) Na(2)HPO(4)-3.49x10(-4) mol l(-1) NaOH (pH 11.4) for the buffer solution, 20 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, respectively. The limit of detection is 5.0x10(-7) mol l(-1) or 0.41 fmol (S/N=3). The linear range of the calibration curve is 1.00x10(-6)-1.00x10(-3) mol l(-1). The relative standard deviation is 1.4% for the migration time and 4.9% for the electrophoretic peak current. The method could be applied to the determination of midecamycin in human urine. In this case, a separation voltage of 14 kV was used.  相似文献   

17.
Chloride self-exchange was determined by measuring the rate of 36Cl efflux from human red blood cells at pH 7.2 (0 degrees C) in the presence of fluoride, bromide, iodide, and bicarbonate. The chloride concentration was varied between 10--400 mM and the concentration of other halides and bicarbonate between 10--300 mM. Chloride equilibrium flux showed saturation kinetics. The half-saturation constant increased and the maximum flux decreased in the presence of halides and bicarbonate: the inhibition kinetics were both competitive and noncompetitive. The competitive and the noncompetitive effects increased proportionately in the sequence: fluoride less than bromide less than iodide. The inhibitory action of bicarbonate was predominantly competitive. The noncompetitive effect of chloride (chloride self-inhibition) on chloride transport was less dominant at high inhibitor concentrations. Similarly, the noncompetitive action of the inhibitors was less dominant at high chloride concentrations. The results can be described by a carrier model with two anion binding sites: a transport site, and a second site which modifies the maximum transport rate. Binding to both types of sites increases proportionately in the sequence: fluoride less than chloride less than bromide less than iodide.  相似文献   

18.
Three fluorescent halide-sensitive quinolinium dyes have been produced by the reaction of the 6-methylquinoline heterocyclic nitrogen base with methyl bromide, methyl iodide, and 3-bromo-1-propanol. The quaternary salts, unlike the precursor molecule, are readily water soluble and the fluorescence intensity of these salts is reduced in the presence of aqueous chloride, bromide, and iodide ions, allowing halide solution concentrations to be determined using well-known Stern-Volmer kinetics. One of the dyes, dye 1, has a chloride Stern-Volmer constant of 255 mol(-1) dm(3) which is more than twice that of SPQ [6-methoxy-N-(3-sulfopropyl)quinolinium] used in recent physiological measurements to measure intracellular chloride levels. The dyes have been characterized using steady-state fluorescence spectroscopy and are compared to three similar dyes based on the 6-methoxyquinoline nucleus, reported earlier by the authors, and also to dyes reported by Krapf et al. (Anal. Biochem. 169, 142-150, 1988). The interference of aqueous anions and the potential for using these dyes in biological halide-sensing applications are discussed.  相似文献   

19.
A high-performance liquid chromatographic method with indirect fluorescence detection has been developed for quantification of dipicolinic acid, a major constituent of bacterial endospores. After separation on a reversed-phase column, a post-column reagent of sodium acetate at 1 mol l(-1) with 50 micromol l(-1) terbium chloride was added for complexation of dipicolinic acid. Terbium monodipicolinate complexes formed were quantified by measuring the fluorescence emission maximum at 548 nm after excitation with UV light at 270 nm wavelength. Parameters of post-column complexation were optimized to achieve a detection limit of 0.5 nmol DPA l(-1), corresponding to about 10(3) Desulfosporosinus orientis endospores per ml. The method was applied to the analysis of spore contamination in tuna and for estimating the endospore numbers in marine sediments.  相似文献   

20.
The promising advantages of Prussian Blue (PB) as catalyst and of the thick film screen printing technology have been combined to assemble sensors with improved characteristics for the amperometric determination of H(2)O(2). PB-modified screen printed electrodes were applied to detect H(2)O(2) at an applied potential of -0.05 V versus the internal screen printed Ag pseudoreference electrode, showing a detection limit of 10(-7) mol l(-1), a linearity range from 10(-7) to 5x10(-5) mol l(-1), a sensitivity of 234 microA mmol l(-1) cm(-2), and a high selectivity. Improved stability at alkaline pH values was also observed, which made possible their use with enzymes having an optimum basic pH. Then, the immobilisation of a single enzyme (glucose oxidase (GOD) or choline oxidase (ChOX)) or of two enzymes, acetylcholinesterase (AchE) coimmobilised with ChOX, has been performed on the surface of PB modified screen-printed electrodes (SPEs) using glutaraldehyde and Nafion. ChOX has been selected as an example of enzyme working at alkaline pH. The choline biosensors showed a detection limit of 5x10(-7) mol l(-1), a wide linearity range (5x10(-7)-10(-4) mol l(-1)), a high selectivity and a remarkable long term stability of 9 months at 4 degrees C, and at least 4 weeks at room temperature. Similar analytical characteristics and stability were observed with the acetylcholine biosensors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号