首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Βackground

Both limb length inequality and scoliosis are associated with pelvic obliquity.

Methods

This is an observational study of adolescents with growth potential presenting for evaluation of thoracic or thoracolumbar idiopathic scoliosis at an outpatient pediatric orthopedic clinic. Patients were evaluated for limb length discrepancy (LLD) (using bilateral femoral head height difference), pelvic obliquity (using bilateral iliac crest height difference and sacral takeoff angle), and scoliotic curve (using Cobb angle and rotation) on full spine standing radiographs. The same radiographic parameters were measured at a follow-up visit at least 2 years later.

Results

Seventy-three consecutive patients with a mean (SD) age of 13.3 (0.2) years at initial examination were included in the study. Scoliosis (major curve Cobb angle ≥?10°) was confirmed in all 73 patients, pelvic obliquity (iliac crest height difference >?1 cm or sacral takeoff angle >?5°) appeared in 23 (31.5%) patients with scoliosis, and LLD (>?1 cm femoral head height difference) was identified in 6 (8.2%) patients with scoliosis and pelvic obliquity. At a subsequent visit, a mean of 2.8 (range 2–5.8) years later, no significant change (p?>?0.05) in limb length inequality was observed but a statistically significant increase (p?<?0.05) in scoliotic and pelvic deformity parameters was found.

Conclusions

In adolescent patient population with thoracic or thoracolumbar scoliosis, the anisomelia remains stable with growth but both the scoliotic deformity and pelvic obliquity progress.

Trial registration

MGH no 2012-P-000774/1
  相似文献   

2.

Background

Needle-free, painless and localized drug delivery has been a coveted technology in the area of biomedical research. We present an innovative way of trans-dermal vaccine delivery using a miniature detonation-driven shock tube device. This device utilizes~2.5 bar of in situ generated oxyhydrogen mixture to produce a strong shockwave that accelerates liquid jets to velocities of about 94 m/s.

Method

Oxyhydrogen driven shock tube was optimized for efficiently delivering vaccines in the intradermal region in vivo. Efficiency of vaccination was evaluated by pathogen challenge and host immune response. Expression levels of molecular markers were checked by qRT-PCR.

Results

High efficiency vaccination was achieved using the device. Post pathogen challenge with Mycobacterium tuberculosis, 100% survival was observed in vaccinated animals. Immune response to vaccination was significantly higher in the animals vaccinated using the device as compared to conventional route of vaccination.

Conclusion

A novel device was developed and optimized for intra dermal vaccine delivery in murine model. Conventional as well in-house developed vaccine strains were used to test the system. It was found that the vaccine delivery and immune response was at par with the conventional routes of vaccination. Thus, the device reported can be used for delivering live attenuated vaccines in the future.
  相似文献   

3.
4.

Background

There are no data in the peer-reviewed literature regarding long term results in patients treated for AIS with a posterior titanium instrumentation. Therefore we assessed the outcome in 50 patients treated by titanium implant.

Methods

A total of 50 patients with a mean age of 16.6 years were treated. In all patients, titanium hooks and pedicle screws were used in combination. The demographic data and the pre- and post-operative radiographs of all 50 patients were re-examined, and 49 of the 50 patients (98%) attended a radiological and clinical follow up-examination on average 10.1 years post-operatively. The clinical results were recorded by means of the SRS 24 questionnaire.

Results

In the frontal plane, the mean pre-operative thoracic and lumbar curve had been 62.4° and 43.5° respectively, post-operatively the curves were reduced to 26.9° and 16.3°, resulting in a correction rate of 56.9% for thoracic and 62.5% for lumbar curve. At the follow up-evaluation, the Cobb angle of the thoracic and lumbar curve was 31.0° and 21.3° respectively, giving a final correction rate of 50.3% for thoracic, and 51.0% for lumbar curve. 7 of the 50 patients (14.3%) had undergo revision surgery for complications, but complete implant removal was necessary in only one case. Analysis of the SRS 24 questionnaire showed an average score of 95.8 points.

Conclusion

Posterior titanium instrumentation is a safe and effective procedure in the surgical correction of AIS. In this retrospective study with small patient number, it shows favourable long-term results; in particular, the loss of correction is low, no late infection occurred and there was a very high survival rate of the implant itself.
  相似文献   

5.

Background

In this paper, we propose a system for data monitoring and control of polymerase chain reaction (PCR) externally. PCR is a technique for amplifying a desired DNA molecule by repeatedly synthesizing a specific part of DNA sequence. Currently, commercially available systems are standalone systems or operate PCR devices through a computer in the vicinity of devices for control purposes. These systems are limited in the number of devices that the host system can monitor at the same time, and there are limitations in controlling devices or accessing experimental data externally. Therefore, we propose a system to control the PCR device via the cloud for the convenience of the user and to overcome the limitation of the place.

Methods

The cloud system used in this study is Google’s Firebase. At this time, we use Firebase Cloud Messaging (FCM) protocol to send and receive data. In this paper, we have experimented on the possibility of data transmission and reception using FCM between device, cloud and user. Since the PCR chips used in the research are generally operated at about 10°/s, and the temperature can be controlled within 0.5°, the processing period of the control process should be made much smaller than 1/20 s (50 ms).

Results

As a result of experiments, the time of the data round-trip using FCM was measured at 150 ms on the average. Therefore, the data exchange time using FCM is three times slower than the reference time of 50 ms.

Conclusions

Since the data round-trip time using FCM is measured to be three times slower than the reference time of 50 ms, it is impossible for the user to control the device such as the PCR device used in this study through the cloud. However, it is possible for the user to monitor the status of the PCR device from the outside in real time.
  相似文献   

6.
7.

Introduction

Data sharing is being increasingly required by journals and has been heralded as a solution to the ‘replication crisis’.

Objectives

(i) Review data sharing policies of journals publishing the most metabolomics papers associated with open data and (ii) compare these journals’ policies to those that publish the most metabolomics papers.

Methods

A PubMed search was used to identify metabolomics papers. Metabolomics data repositories were manually searched for linked publications.

Results

Journals that support data sharing are not necessarily those with the most papers associated to open metabolomics data.

Conclusion

Further efforts are required to improve data sharing in metabolomics.
  相似文献   

8.

Background

Here we investigated the influence of different stabilization and storage strategies on the quality and composition of the fecal microbial community. Namely, same-day isolated murine DNA was compared to samples stored for 1 month in air at ambient temperature, with or without preservative buffers (i.e. EDTA and lysis buffer), different temperatures (i.e. 4?°C, ??20?°C, and???80?°C), and hypoxic conditions.

Results

Only storage in lysis buffer significantly reduced DNA content, yet without integrity loss. Storage in EDTA affected alpha diversity the most, which was also reflected in cluster separation. Distinct changes were also seen in the phyla and bacterial species abundance per storage strategy. Metabolic function analysis showed 22 pathways not significantly affected by storage conditions, whereas the tyrosine metabolism pathway was significantly changed in all strategies except by EDTA.

Conclusion

Each long-term storage strategy introduced a unique post-collection bias, which is important to take into account when interpreting data.
  相似文献   

9.

Background

Few finite element models (FEM) have been developed to describe the electric field, specific absorption rate (SAR), and the temperature distribution surrounding hepatic radiofrequency ablation probes. To date, a coupled finite element model that accounts for the temperature-dependent electrical conductivity changes has not been developed for ablation type devices. While it is widely acknowledged that accounting for temperature dependent phenomena may affect the outcome of these models, the effect has not been assessed.

Methods

The results of four finite element models are compared: constant electrical conductivity without tissue perfusion, temperature-dependent conductivity without tissue perfusion, constant electrical conductivity with tissue perfusion, and temperature-dependent conductivity with tissue perfusion.

Results

The data demonstrate that significant errors are generated when constant electrical conductivity is assumed in coupled electrical-heat transfer problems that operate at high temperatures. These errors appear to be closely related to the temperature at which the ablation device operates and not to the amount of power applied by the device or the state of tissue perfusion.

Conclusion

Accounting for temperature-dependent phenomena may be critically important in the safe operation of radiofrequency ablation device that operate near 100°C.
  相似文献   

10.

Introduction

Aqueous–methanol mixtures have successfully been applied to extract a broad range of metabolites from plant tissue. However, a certain amount of material remains insoluble.

Objectives

To enlarge the metabolic compendium, two ionic liquids were selected to extract the methanol insoluble part of trunk from Betula pendula.

Methods

The extracted compounds were analyzed by LC/MS and GC/MS.

Results

The results show that 1-butyl-3-methylimidazolium acetate (IL-Ac) predominantly resulted in fatty acids, whereas 1-ethyl-3-methylimidazolium tosylate (IL-Tos) mostly yielded phenolic structures. Interestingly, bark yielded more ionic liquid soluble metabolites compared to interior wood.

Conclusion

From this one can conclude that the application of ionic liquids may expand the metabolic snapshot.
  相似文献   

11.

Objectives

To optimize conversion of rutin to isoquercetin by commercial α-l-rhamnosidase using high hydrostatic pressure (HHP).

Results

The de-rhamnosylation activity of α-l-rhamnosidase for isoquercetin production was maximal at pH 6.0 and 50 °C using HHP (150 MPa). The enzyme showed high specificity for rutin. The specific activity for rutin at HHP was 1.5-fold higher than that at atmospheric pressure. The enzyme completely hydrolysed 20 mM rutin in tartary buckwheat extract after 2 h at HHP, with a productivity of 10 mM h?1. The productivity and conversion were 2.2- and 1.5-fold higher at HHP than at atmospheric pressure, respectively.

Conclusions

This is the first report concerning the enzymatic hydrolysis of isoquercetin in tartary buckwheat at HHP.
  相似文献   

12.

Background

The changes of hemodynamics and drug concentration distribution caused by the implantation of drug eluting stents (DESs) in curved vessels have significant effects on In-Stent Restenosis.

Methods

A 3D virtual stent with 90°curvature was modelled and the distribution of wall shear stress (WSS) and drug concentration in this model were numerically studied at Reynolds numbers of 200, 400, 600, 800.

Results

The results showed that (1) the intensity of secondary flow at the 45° cross-section was stronger than that at the 90° cross-section; (2) As the Reynolds number increases, the WSS decreases. When the Reynolds number reaches 600, the low-WSS region only accounts for 3% of the total area. (3) The effects of Reynolds number on drug concentration in the vascular wall decreases in proportionally and then the blood velocity increased 4 times, the drug concentration in the vascular wall decreased by about 30%. (4) The size of the high drug concentration region is inversely proportional to the Reynolds number. As the blood velocity increases, the drug concentration in the DES decreases, especially at the outer bend.

Conclusions

It is beneficial for the patient to decrease vigorous activities and keep calm at the beginning of the stent implantation, because a substantial amount of the drug is released in the first two months of stent implantation, thus a calm status is conducive to drug release and absorption; Subsequently, appropriate exercise which increases the blood velocity is helpful in decreasing regions of low-WSS.
  相似文献   

13.

Objective

To determine if there is any non-linearity in the biomagnetic recordings of uterine myomas and to find any differences that may be present in the mechanisms underlying their signal dynamics.

Methods

Twenty-four women were included in the study. Sixteen of them were characterised with large myomas and 8 with small ones. Uterine artery waveform measurements were evaluated by use of Pulsatility Index (PI) (normal value PI<1.45).

Results

Applying nonlinear analysis to the biomagnetic signals of the uterine myomas, we observed a clear saturation value for the group of large ones (mean = 11.35 ± 1.49) and no saturation for the small ones.

Conclusion

The comparison of the saturation values in the biomagnetic recordings of large and small myomas may be a valuable tool in the evaluation of functional changes in their dynamic behavior.
  相似文献   

14.

Background

Effect of neurofeedback training (NFT) on enhancement of cognitive function or amelioration of clinical symptoms is inconclusive. The trainability of brain rhythm using a neurofeedback system is uncertainty because various experimental designs are used in previous studies. The current study aimed to develop a portable wireless NFT system for alpha rhythm and to validate effect of the NFT system on memory with a sham-controlled group.

Methods

The proposed system contained an EEG signal analysis device and a smartphone with wireless Bluetooth low-energy technology. Instantaneous 1-s EEG power and contiguous 5-min EEG power throughout the training were developed as feedback information. The training performance and its progression were kept to boost usability of our device. Participants were blinded and randomly assigned into either the control group receiving random 4-Hz power or Alpha group receiving 8–12-Hz power. Working memory and episodic memory were assessed by the backward digital span task and word-pair task, respectively.

Results

The portable neurofeedback system had advantages of a tiny size and long-term recording and demonstrated trainability of alpha rhythm in terms of significant increase of power and duration of 8–12 Hz. Moreover, accuracies of the backward digital span task and word-pair task showed significant enhancement in the Alpha group after training compared to the control group.

Conclusions

Our tiny portable device demonstrated success trainability of alpha rhythm and enhanced two kinds of memories. The present study suggest that the portable neurofeedback system provides an alternative intervention for memory enhancement.
  相似文献   

15.

Objectives

To establish a method for microbial transglutaminase (mTG)-mediated PEGylation of proteins at the level of lysine (Lys) residues.

Results

Carboxybenzyl-glutaminyl–glycinyl-methoxypolyethylene glycol (CBZ-QG-mPEG) was prepared by introducing carboxybenzyl-glutaminyl-glycine (CBZ-QG) to mPEG amine. The analysis by Fourier transform infrared spectroscopy and SDS-PAGE showed that CBZ-QG-mPEG was successfully synthesized and can be recognized by mTG as an acyl donor to modify therapeutic protein, cytochrome c (cyt c). Finally, under an optimized condition (cyt c 0.5 mg/ml, CBZ-QG-mPEG 11.25 mg/ml, mTG 0.5 mg/ml, 37 °C, 2 h), the PEGylation yield reached 76.5 %.

Conclusions

This is the first study regarding the PEGylation of protein at the level of Lys residues catalyzed by mTG. The novel method could be employed to immobilize active proteins and modify therapeutic proteins.
  相似文献   

16.

Background

First author attempted to analyse medical records of patients with idiopathic scoliosis for compliance with the Scoliosis Research Society brace studies criteria. A retrospective analysis of medical records of 2705 girls treated from 1989 to 2002 was carried out.

Methods

Age, Cobb, Risser and menarchal status were analyzed for compliance with the Scoliosis Research Society brace studies criteria: a) age ≥10 years, b) Risser 0–2, c) 25–40° Cobb angle, d) no earlier treatment, e) patients before first menses or not more than one year from first menses.

Results

It has been found that 183 girls out of 2705 were ≥10 years old and in the range 25–40° Cobb angle. One hundred two out of 2705 patients revealed eligible for brace effectiveness study according to SRS 2005 criteria. 120 out of 2705 patients revealed eligible for brace brace effectiveness study according to SRS-SOSORT 2014 criteria.

Conclusion

The excluded patients revealed too old or with too significant Cobb angles. This indicates the changing criteria for scoliosis brace treatment over the time. Direct comparison of current results of brace treatment with historical series of cases turns out to be very difficult.
  相似文献   

17.

Background and aims

Mineralization of soil organic matter (SOM) constitutes a major carbon flux to the atmosphere. The carbon use efficiency (CUE) of the saprotrophic microorganisms mineralizing SOM is integral for soil carbon dynamics. Here we investigate how the CUE is affected by temperature, metabolic conditions, and the molecular complexity of the substrate.

Methods

We incubated O-horizon soil samples (with either 13C–glucose or 13C–cellulose) from a boreal coniferous forest at 4, 9, 14, and 19 °C, and calculated CUEs based on the amount of 13C–CO2 and 13C–labelled microbial biomass produced. The effects of substrate, temperature, and metabolic conditions (representing unlimited substrate supply and substrate limitation) on CUE were evaluated.

Results

CUE from metabolizing glucose was higher as compared to cellulose. A slight decrease in CUE with increasing temperature was observed in glucose amended samples (but only in the range 9–19 °C), but not in cellulose amended samples. CUE differed significantly with metabolic conditions, i.e. CUE was higher during unlimited growth conditions as compared to conditions with substrate limitation.

Conclusions

We conclude that it is integral to account for both differences in CUE during different metabolic phases, as well as complexity of substrate, when interpreting temperature dependence on CUE in incubation studies.
  相似文献   

18.

Background

Transcutaneous neurostimulation (TNS) at extracephalic sites is a well known treatment of pain. Thanks to recent technical progress, the Cefaly® device now also allows supraorbital TNS. During observational clinical studies, several patients reported decreased vigilance or even sleepiness during a session of supraorbital TNS. We decided therefore to explore in more detail the potential sedative effect of supraorbital TNS, using standardized psychophysical tests in healthy volunteers.

Methods

We performed a double-blind cross-over sham-controlled study on 30 healthy subjects. They underwent a series of 4 vigilance tests (Psychomotor Vigilance Task, Critical Flicker Fusion Frequency, Fatigue Visual Numeric Scale, d2 test). Each subject was tested under 4 different experimental conditions: without the neurostimulation device, with sham supraorbital TNS, with low frequency supraorbital TNS and with high frequency supraorbital TNS.

Results

As judged by the results of three tests (Psychomotor Vigilance Task, Critical Flicker Fusion Frequency, Fatigue Visual Numeric Scale) there was a statistically significant (p < 0.001) decrease in vigilance and attention during high frequency TNS, while there were no changes during the other experimental conditions. Similarly, performance on the d2 test was impaired during high frequency TNS, but this change was not statistically significant.

Conclusion

Supraorbital high frequency TNS applied with the Cefaly® device decreases vigilance in healthy volunteers. Additional studies are needed to determine the duration of this effect, the underlying mechanisms and the possible relation with the stimulation parameters. Meanwhile, this effect opens interesting perspectives for the treatment of hyperarousal states and, possibly, insomnia.
  相似文献   

19.

Background

Infant feeding is governed by environmental as well as cultural factors. Breastfeeding knowledge and attitudes are known to be associated with breastfeeding duration. This study investigated breastfeeding information, attitudes and supplementary feeding in the central hills district of Nepal.

Methods

A community-based prospective cohort study of 701 pregnant women was conducted. Information on breastfeeding attitudes, feeding practices and supplementary feeding was sought from the cohort at 4 weeks, 12 weeks and 22 weeks postpartum through repeated interviews using validated questionnaires.

Results

Average duration of intended breastfeeding was 28 months (SD 7.9) and average target time to introduce solid foods was 6.1 months (SD 1.2). About 80% of women reported their husband, mother/mother-in-law preferred breastfeeding. Eleven percent of the cohort said that breastfeeding was not enjoyable. At 12 weeks and 22 weeks after birth, about a quarter (24.8%) and half (52.8%) of the infants were introduced cow/buffalo milk, respectively, while only 6.3% and 13.4% of them were given infant formula. Overall, any breastfeeding rate remained high at over 98% throughout the follow up period.

Conclusions

Breastfeeding attitudes were encouraging in this population. Breastfeeding was almost universal. Use of infant formula was quite low, whereas cow or buffalo milk appeared to be popular supplementary foods.
  相似文献   

20.

Objectives

To characterize biomarkers that underlie osteosarcoma (OS) metastasis based on an ego-network.

Results

From the microarray data, we obtained 13,326 genes. By combining PPI data and microarray data, 10,520 shared genes were found and constructed into ego-networks. 17 significant ego-networks were identified with p < 0.05. In the pathway enrichment analysis, seven ego-networks were identified with the most significant pathway.

Conclusions

These significant ego-modules were potential biomarkers that reveal the potential mechanisms in OS metastasis, which may contribute to understanding cancer prognoses and providing new perspectives in the treatment of cancer.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号