1.
《Ecological Engineering》2005,24(3):185-198
In 2001, to foster the practical development of constructed wetlands (CWs) used for domestic wastewater treatment in Turkey, vertical subsurface flow constructed wetlands (30 m2 of each) were implemented on the campus of the METU, Ankara, Turkey. The main objective of the research was to quantify the effect of different filter media on the treatment performance of vertical flow wetlands in the prevailing climate of Ankara. Thus, a gravel-filled wetland and a blast furnace granulated iron slag-filled wetland were operated identically with primarily treated domestic wastewater (3 m3 d−1) at a hydraulic loading rate of 0.100 m d−1, intermittently. Both of the wetland cells were planted with Phragmites australis. According to the first year results, average removal efficiencies for the slag and gravel wetland cells were as follows: total suspended solids (TSS) (63% and 59%), chemical oxygen demand (COD) (47% and 44%), NH4+–N (88% and 53%), total nitrogen (TN) (44% and 39%), PO43−-P (44% and 1%) and total phosphorus (TP) (45% and 4%). The treatment performances of the slag-filled wetland were better than that of the gravel-filled wetland in terms of removal of phosphorus and production of nitrate. Since this study was a pioneer for implementation of subsurface constructed wetlands in Turkey using local sources, it has proved that this eco-technology could also be used effectively for water quality enhancement in Turkey.  相似文献   

2.
A wetland system has operated seasonally at Saginaw Township, MI, USA, for ten years. The system consists of extraction, aeration, settling, intermittent vertical sand filtration, a surface flow wetland treatment with recycle, and discharge to the Tittibawassee River. The 0.85 ha cattail wetland treats the full leachate flow, with a total system detention time of 180 days. The high recycle rate creates a lesser wetland detention time of 60 days. Ammonia is the principal contaminant of concern, because it occurs at high concentrations, typically 300–500 mg/L. Ammonia mass reduction averaged 99.5% for the last nine years, with a 95% mass removal in the startup year. Metals were not present in all samples, with modest reductions in those always present (zinc 16%, arsenic 29%, barium 78%, chromium 67%). Volatile organic compounds were removed to below detection, excepting BTEX, which occurred in only 2% of the outflow samples. Base neutral organics, PCBs and pesticides were also removed to below detection, excepting phthalates with an outlet detection frequency of 29%. No pesticides or PCBs were detected in the system outflow. The ammonia removal rate coefficients for the wetland (12 m/yr) was at the 55th percentile of the distribution for other surface flow wetlands. The vertical filter was likely oxygen limited, and functioned with an apparent oxygen utilization of 30 gO/(m2 d).  相似文献   

3.
The use of surface flow (SFCWs) and subsurface flow constructed wetlands (SFCWs) for the treatment of combined sewer overflows was assessed at pilot scale. Synthetic wastewater was applied in three batches with decreasing concentrations to mimic concentration profiles that are obtained in the field during overflow events. Three simulated combined sewer overflows were applied on each wetland. Composite water samples (60 in total) were taken for a period of 8 days to study the removal of total nitrogen (Ntot), NH4–N, NO3–N, total COD (CODtot) and total phosphorus. Redox potential, which was monitored at various locations along the wetlands, was more negative in the SSFCWs. In general, removal occurred faster in the SSFCWs and the final concentrations were lower. The removal of Ntot was only 36.6 ± 3.3% in the SFCWs due to nitrification-limiting conditions. The conditions in the SSFCWs, in contrast, seemed to promote Ntot removal (removal efficiency 96.7 ± 1.9%). The removal of P was hampered in both wetland types by reducing conditions. P that was initially removed was released again from the substrates later on. First-order removal rate constants were derived for the removal of both CODtot (SSFCWs: 1.1 ± 0.3 m d?1; SFCWs: 0.17 ± 0.06 m d?1) and Ntot (SSFCWs: 0.4 ± 0.1 m d?1; SFCWs: 1.7 ± 0.5 m d?1).  相似文献   

4.
《Ecological Engineering》2007,29(2):154-163
The South Nation River Watershed, in eastern Ontario, Canada, is an agricultural watershed impacted by excess nutrient loading primarily from agricultural activities. A constructed wetland for the treatment of agricultural wastewater from a 150-cow dairy operation in this watershed was monitored in its eighth operating season to evaluate the proportion of total nitrogen (TN) (approximated by total Kjeldahl nitrogen (TKN) due to low NO3) and total phosphorus (TP) removal that could be attributed to storage in Typha latifolia L. and Typha angustifolia L., which dominate this system. Nutrient loading rates were high, with 16.2 kg ha−1 d−1 N and 3.4 kg ha−1 d−1 P entering the wetland and loading the first wetland cell. Plant uptake accounted for 0.7% of TKN removal when the vegetated free water surface cells were considered together. However, separately, in the second wetland cell with lower N and P loading rates, plants accounted for 9% of TKN, 21% of NH4+ and 5% of TP removal. Plant uptake was significant to overall removal given wetland age and nutrient loading. Nutrient storage during the growing season at this constructed wetland helped reduce the nutrient load entering the watershed, already stressed by intensive local agriculture.  相似文献   

5.
Treatment of various types of wastewaters is an urgent problem in densely populated areas of many tropical countries. We studied the potential of using Sesbania sesban, an N2-fixing shrub, in constructed wetland systems for the treatment of high-strength wastewater. A replicated horizontal subsurface flow system and a saturated vertical downflow system was established with planted and unplanted beds to assess the effects of system design and presence of plants on treatment performance. The systems were loaded with a mixture of domestic and pig farm wastewater at three hydraulic loading rates of 80, 160 and 320 mm d?1. The S. sesban plants grew very well in the constructed wetland systems and produced 17.2–20.2 kg dry matter m?2 year?1 with a high nitrogen content. Mass removal rates and removal rate constants increased with loading rate, but at 320 mm d?1 the effluent quality was unacceptable and hydraulic problems appeared. Mass removal rates and removal rate constants were much higher than reported in other studies probably because of the high-strength wastewater, the high loading rates and the tropical conditions. Planted systems removed pollutants much more efficiently than the unplanted controls. Direct plant uptake constituted only up to 8% of the total-N removal and 2% of the P removal at the lowest loading rate, and was quantitatively of low importance compared to other removal processes. The significant effects of plants were therefore related more to their indirect effects on the removal processes. This study for the first time documents that S. sesban can be used in constructed wetland systems for the treatment of polluted water while at the same time producing a valuable N rich biomass that can be used for animal fodder or soil amendment.  相似文献   

6.
The life-cycle greenhouse gaseous emissions and primary exergy resources consumption associated with a horizontal subsurface flow constructed wetland (HSSF) were investigated. The subject of study was a wetland for municipal wastewater treatment with a 700-person-equivalent capacity. The effects of two types of emergent aquatic macrophytes (Phragmites australis and Schoenoplectus californicus) and seasonality on greenhouse gas (GHG) gas emissions, the environmental remediation cost (ERC) and the specific environmental remediation cost (SERC) were assessed. The results indicate that GHG emissions per capita (12–22 kgCO2eq/p.e/yr) and primary exergy resources consumed (24–27 MJ/m3) for the HSSF are lower than those of a conventional wastewater treatment plant (67.9 kgCO2eq/p.e/yr and 96 MJ/m3). The SERC varied between 176 and 216 MJ/kg biological oxygen demand (BOD5) removal, which should be further reduced by 20% for an improved BOD5 removal efficiency above 90%. The low organic matter removal efficiency is associated with a high organic load and low bacterial development. Seasonality has a marked effect on the organic removal efficiency and the SERC, but the macrophyte species does not.  相似文献   

7.
《Ecological Engineering》2006,26(3):272-282
A full-scale constructed wetlands system with a total area of 80 ha and treatment capability of 2.0 × 104 m3 d−1 was completed in October 1998 in Rongcheng, Shandong Province, China. To evaluate wastewater treatment effectiveness and seasonal performance of the system, water samples were collected and analyzed from January 1999 to December 2004. Comparison of mean inlet and outlet concentrations showed that the constructed wetland system could effectively reduce the output of SS (71.8 ± 8.4%), BOD5 (70.4 ± 9.6%), COD (62.2 ± 10.1%), total coliform (99.7%) and fecal coliform (99.6%). However, the percent reduction of ammonia nitrogen was relatively low (40.6 ± 15.3%), and total phosphorus showed the least efficient reduction (29.6 ± 12.8%). BOD5, COD, ammonia nitrogen, and total phosphorus removal efficiencies displayed seasonal variations. BOD5 and COD removal was more efficient in spring and summer than in autumn and winter whereas ammonia nitrogen and total phosphorus removal was more efficient in summer and autumn than in spring and winter. Annual variation analysis shows that COD, BOD5, and ammonia nitrogen reduction efficiencies increased from 1999 to 2004. In contrast, mean total phosphorus reduction efficiency did not change from 2001 to 2002 and began to decrease from 2003 onwards.  相似文献   

8.
The dairy industry is generally considered to be the largest source of food processing wastewater in many countries. The highly variable nature of dairy wastewaters in terms of volumes and flowrates and in terms of high organic materials contents such as COD 921–9004 mg L−1, BOD 483–6080 mg L−1, TN of 8–230 mg L−1 and SS of 134–804 mg L−1 makes the choice of an effective wastewater treatment regime difficult. A high performance bioreactor, an aerobic jet loop reactor, combined with a ceramic membrane filtration unit, was used to investigate its suitability for the treatment of the dairy processing wastewater. The oxygen transfer rates of the bioreactor were found to be very high (100–285 h−1) on the operating conditions. A loading rate of 53 kg COD m−3 d−1 resulted in 97–98% COD removal efficiencies under 3 h hydraulic retention time. The high MLSS concentrations could be retained in the system (up to 38,000 mg L−1) with the contribution of UF (ultrafiltration) unit. During the filtration of activated sludge, the fluxes decreased with increasing MLSS. Cake formation fouling was determined as dominant fouling mechanisms. The results demonstrate that jet loop membrane bioreactor system was a suitable and effective treatment choice for treating dairy industry wastewater.  相似文献   

9.
The experiment was conducted to develop an integrated treatment system for coffee processing wastewater (CPWW) through the combination of biomethanation with aeration and wetland plants treatment. The biomethanation was carried out at different hydraulic retention times (HRTs) using upflow anaerobic hybrid reactor (UAHR) and 18 h of HRT was found to be optimum. The maximum biochemical oxygen demand (BOD), chemical oxygen demand (COD) and total solids (TS) reduction were 66.0%, 61.0% and 58.0%, respectively with organic loading rate of 9.55 kg m?3 day?1. The reduction of pollution load of the wastewater by microbial action augmented by aeration resulted in the reduction of electrical conductivity (EC), BOD, COD, and total solids (TS). Continuous aeration of wastewater resulted in maximum reduction of BOD (74.6%), COD (68.6%) and TS (49.3%). The wetland plant, Typha latifolia reduced 85.4% and 78.0% of BOD and COD, respectively in biomethanated cum aerated CPWW.  相似文献   

10.
Integration of partial nitrification (nitritation) and anaerobic ammonium oxidation (anammox) in constructed wetlands creates a sustainable design for nitrogen removal. Three wetland treatment systems were operated with synthetic wastewater (60 mg NH3–N L?1) in a batch mode of fill – 1-week reaction – drain. Each treatment system had a surface flow wetland (unplanted, planted, and planted plus aerated, respectively) with a rooting substrate of sandy loam and limestone pellets, followed by an unplanted subsurface flow wetland. Meanwhile, three surface flow wetlands with a substrate of sandy loam and pavestone were operated in parallel to the former surface flow wetlands. Influent and effluent were monitored weekly for five cycles. Aeration reduced nitrogen removal due to hindered nitrate reduction. Vegetation maintained pH near neutral and moderate dissolved oxygen, significantly improved ammonia removal by anammox, and had higher TN removal due to coexistence of anammox and denitrification in anaerobic biofilm layers. Nitrite production was at a peak at the residence time of 4–5 d. Relative to pavestone, limestone increased the nitrite mass production peak by 97%. The subsurface flow wetlands removed nitrogen via nitritation and anammox, having an anammox activity of up to 2.4 g N m?3 d?1 over a startup operation of two months.  相似文献   

11.
In Egypt, disposing of partially treated or untreated domestic and industrial wastewater into agricultural drains deteriorates their water quality. A growing interest in effective low-cost treatment of polluted water and wastewater has resulted in many studies on constructed wetlands.This study evaluates free water surface constructed wetlands (by far the largest application project is named “Lake Manzala Engineered Wetland [Egypt]”) utilized to improve the water quality in Bahr El Baqar drain, which is located at the northeastern edge of the Nile Delta. This drain discharges its water into Manzala Lake, which in turn has many fishing activities and is connected to the Mediterranean Sea. The full capacity of the constructed wetland system is 25,000 m3/day. Three various flow rate wetlands were investigated; five wetland beds of high flow rate of 0.344 m3/m2-day, five wetland beds of low flow rate of 0.048 m3/m2-day and reciprocated cells of flow of 500 m3/day.The concentrations of different contaminants along the constructed wetlands system were measured to determine the treatment efficiency. The effluent was compared with the Egyptian standards of water quality in agricultural drains (Law 48/1982). Due to the high percentage of the agricultural water drain, the concentrations of contaminants in the influent were relatively low. The percentages of removal for the different contaminants were BOD5: 52%, COD: 50%, TSS: 87%, TDS: 32%, NH4-N: 66%, PO4: 52%, Fe: 51%, Cu: 36%, Zn: 47% and Pb: 52%. The natural vegetation considerably increased the value of dissolved oxygen in the treated effluent. There were little differences in the removal efficiency between the high and low flow rates beds in the system.  相似文献   

12.
The treatment capacity of constructed wetlands is expected to be high in tropical areas because of the warm temperatures and the associated higher rates of microbial activity. A pilot scale horizontal subsurface flow constructed wetland system filled with river sand and planted with Phragmites vallatoria (L.) Veldkamp was set up in the southern part of Vietnam to assess the treatment capacity and the removal rate kinetics under tropical conditions. The system received municipal wastewater at four hydraulic loading rates (HLRs) of 31, 62, 104 and 146 mm day?1. Removals of TSS, BOD5 and COD were efficient at all HLRs with mean removal rates of 86–95%, 65–83% and 57–84%, respectively. Removals of N and P decreased with HLRs and were: NH4-N 0–91%; TN 16–84% and TP 72–99%. First-order area-based removal rate constants (k, m year?1) estimated from sampling along the length of the wetland from inlet to outlet at the four HLRs were in the range of 25–95 (BOD5), 22–30 (COD), 31–115 (TSS), 5–24 (TN and TKN) and 41–84 (TP) at background concentrations (C*) of 5, 10, 0, 1.5 and 0 mg L?1, respectively. The estimated k-values should not be used for design purposes, as site-specific differences and stochastic variability can be high. However, the study shows that domestic wastewater can be treated in horizontal subsurface flow constructed wetland systems to meet even the most stringent Vietnamese standards for discharge into surface waters.  相似文献   

13.
Constructed treatment wetlands have served the City of Columbia, MO, for fourteen years. Four free water surface wetland units in series, comprised of 23 cells, are an addition to the activated sludge wastewater treatment plant, for the purpose of added biochemical oxygen demand (BOD) and total suspended solids (TSS) control. The system operates year-round, and supplies water to the Eagle Bluffs Conservation Area for wetland maintenance. The cattail wetlands processed an average of 57,000 m3/d, at a water depth of 20 cm. The resulting detention time was approximately 2 days, and the hydraulic loading was 13 cm/d. Water temperatures were warm leaving the treatment plant and in the wetlands in winter, because of the short detention. The period of record average carbonaceous biochemical oxygen demand (CBOD) leaving the wetlands was 5.0 mg/L, and the TSS was 14.7 mg/L. Dissolved oxygen was depressed in summer, likely because of the high sediment demand. Nutrient concentrations were only minimally reduced, total nitrogen (TN) by 22% and total phosphorus (TP) by 6%. However, load reductions were maximal, 98 t/yr for nitrogen, and 3.6 t/yr for phosphorus. Fecal coliforms were reduced by 98%, and E. coli by 95%. First order rate coefficients were high for CBOD (64 m/yr), nitrate (61 m/yr) and organic nitrogen (42 m/yr), but relatively low for ammonia (8 m/yr) and phosphorus (5.7 m/yr). Nitrogen removal was strongly affected by vegetative uptake. Sediment accretion in the wetland inlets was substantial, at 1.6 cm/yr in the inlets to the upstream wetland units. Muskrats caused vegetation damage, and waterfowl use was high in winter, causing TSS excursions.  相似文献   

14.
This paper describes the thermophilic (55 °C) anaerobic biodegradation of a mixed feed composed of vinasses and cutting oil wastewater (COW) in a laboratory upflow anaerobic fixed-film reactor (UAFF) with a porous support medium. The experimental protocol was defined to examine the effect of increasing the percentage of cutting oil wastewater in the feed.The UAFF reactor was initially started-up with vinasses as the only carbon source at an organic loading rate of 22.3 kg COD/m3 day and HRT of 0.8 days using porous particles as the support (SIRAN). The percentage of organic matter composed of vinasses was subsequently reduced while increasing the amount of cutting oil until 100% of cutting oil wastewater was added in the feed. Four stages were considered in the study (0, 42.4, 66.6 and 100% COW). HRT was adjusted in order to maintain an approximately constant organic loading rate applied to the system. Under theses conditions, the UAFF reactor was subjected to a programme of steady-state operation with hydraulic retention times (HRT) in the range 0.8–0.15 days and organic loading rates (OLR) between 22.3 and 14.9 kg COD/m3 day in order to evaluate the treatment capacity of the system.The COD removal efficiency was found to be 87% COD and 94.6% TOC in the reactor when treating vinasses at 22.3 kg COD/m3 day. The volumetric methane level produced in the digester reached 0.45 m3/m3 day. After an operating period of 120 days, the reactor was fed with cutting oil wastewater (COW) as the only source of carbon. An OLR of 16.7 kg COD/m3 day was achieved with 85.8% COD removal efficiency (58.1%TOC) in the experimental UAFF reactor. Under these conditions the volumetric methane produced in the digester was negligible.Hence, COW can be removed, if not degraded, by anaerobic treatment in the presence of a biodegradable co-substrate. Wine vinasses degradation creates conditions for non-biological removal of COW constituents. More studies are necessary in order to test the mechanisms of organic removal when biodegradation apparently had ceased. Also, toxicity assays of COW are necessary to evaluate the toxicity to the methanogenic community.  相似文献   

15.
New technologies regarding wastewater treatment have been developed. Among these technologies, the moving bed biofilm reactor combined with membrane bioreactor (MBBR-MBR) is a recent solution alternative to conventional processes. This paper presents the results obtained from three wastewater treatment plants working in parallel. The first wastewater treatment plant consisted of a membrane bioreactor (MBR), the second one was a MBBR-MBR system containing carriers both in anoxic and aerobic zones, and the last one consisted of a MBBR-MBR system which contained carriers only in the aerobic zone. The reactors operated with a hydraulic retention time of 26.47 h. During the study, the difference between the experimental plants was not statistically significant concerning organic matter and nutrients removal. However, different tendencies regarding nutrients removal are shown by the three wastewater treatment plants. In this sense, the performances in terms of nitrogen and phosphorus removal of the MBBR-MBR system which contained carriers only in the aerobic zone (67.34 ± 11.22% and 50.65 ± 11.13%, respectively) were slightly better than those obtained from another experimental plants. As a whole, the pilot plant which consisted of a MBR showed better performance from the point of view of the kinetics of the heterotrophic and autotrophic biomass with values of μm,H = 0.00858 h−1, μm,A = 0.07646 h−1, KM = 2.37 mg O2 L−1 and KNH = 1.31 mg N L−1.  相似文献   

16.
This paper analyses the purification efficiency and mass removal of organic material, suspended solids, nitrogen and phosphorus in a hybrid constructed wetland (CW) system treating wastewater from a basic school in Paistu, Estonia. The CW consists of two subsurface flow filter beds using lightweight aggregates (LWA): a two-chamber vertical subsurface flow (VSSF) filter bed followed by a horizontal subsurface flow (HSSF) filter bed, with a total area of 432 m2. This CW was constructed in summer 2002 by the Centre for Ecological Engineering in Tartu (CEET). Eighteen series of water samples (from 30.10.2003 to 15.10.2005) were undertaken. The analyses show the outstanding purification effect of the system: for BOD7 the average purification efficiency is 91%; for total suspended solids (TSS)—78%, for total P—89%, for total N—63%, and for NH4N—77%. The average outlet values for the above-listed parameters were 5.5, 7.0, 0.4, 19.2 and 9.1 mg L−1, respectively. According to our results, the purification parameters meet the standards set by the Water Act of Estonia for wastewater treatment plants of 2000–9999 PE: 15, 25, and 1.5 mg L−1 for BOD7, TSS and total P, respectively. The results show that hybrid CW systems consisting of subsurface flow filter beds can work efficiently in conditions of changing hydraulic loading and relatively cold climate. We did not find significant differences between the removal efficiency, mass removal, and values of the first-order rate-constant k for most water quality indicators during the warm (May–October) and cold (November–April) periods. Locally produced LWA as a filter material in CWs has shown good hydraulic conductivity and phosphorus sorption capacity (k = 17.1 ± 12.4 m yr−1). The Paistu CW, with its proper design and outstanding purification results, can be considered one of the best systems in Estonia.  相似文献   

17.
The ability of vertical flow (VF) constructed wetland systems to treat high-strength (ca. 300 mg L?1 of COD and ca. 300 mg L?1 total-nitrogen) wastewater under tropical climatic conditions was studied during a 5-month period. Nine 0.8-m diameter experimental VF units (depth 0.6 m) were used: three units were planted with Typha angustifolia L., another three units were planted with Cyperus involucratus Rottb and three units were unplanted. Each set of units were operated at hydraulic loading rates (HLRs) of 20, 50 and 80 mm d?1. Cyperus produced more shoots and biomass than the Typha, which was probably stressed because of lack of water. The high evapotranspirative water loss from the Cyperus systems resulted in higher effluent concentrations of COD and total-P, but the mass removal of COD did not differ significantly between planted and unplanted systems. Average mass removal rates of COD, TKN and total-P at a HLR of 80 mm d?1 were 17.8, 15.4 and 0.69 g m?2 d?1. The first-order removal rate constants at a HLR of 80 mm d?1 for COD, TKN and total-P were 49.8, 30.1 and 13.5 m year?1, respectively, which is in the higher range of k-values reported in the literature. The oxygen transfer rates were ca. 80 g m?2 d?1 in the planted systems as opposed to ca. 60 g m?2 d?1 in the unplanted systems. The number of Nitrosomonas was two to three orders of magnitude higher in the planted systems compared to the unplanted systems. Planted systems thus had significantly higher removal rates of nitrogen and phosphorus, higher oxygen transfer rates, and higher quantities of ammonia-oxidizing bacteria. None of the systems did, however, fully nitrify the wastewater, even at low loading rates. The vertical filters did not provide sufficient contact time between the wastewater and the biofilm on the gravel medium of the filters probably because of the shallow bed depth (0.6 m) and the coarse texture of the gravel. It is concluded that vertical flow constructed wetland systems have a high capacity to treat high-strength wastewater in tropical climates. The gravel and sand matrix of the vertical filter must, however, be designed in a way so that the pulse-loaded wastewater can pass through the filter medium at a speed that will allow the water to drain before the next dose arrives whilst at the same time holding the water back long enough to allow sufficient contact with the biofilm on the filter medium.  相似文献   

18.
A horizontal subsurface flow (HSSF) and a free water surface flow (FWSF) constructed wetlands (4 m2 of each) were set up on the campus of Harran University, Sanliurfa, Turkey. The main objective of the research was to compare the performance of two systems to decide the better one for future planning of wastewater treatment system on the campus. Both of the wetland systems were planted with Phragmites australis and Canna indica. During the observation period (10 months), environmental conditions such as pH, temperature and total chemical oxygen demand (COD), soluble COD, total biochemical oxygen demand (BOD), soluble BOD, total suspended solids (TSS), total phosphate (TP), total nitrogen (TN) removal efficiencies of the systems were determined. According to the results, average yearly removal efficiencies for the HSSF and the FWSF, respectively, were as follows: total COD (75.7% and 69.9%), soluble COD (85.4% and 84.3%), total BOD (79.6% and 87.6%), soluble BOD (87.7% and 95.3%), TN (33.2% and 39.4%), and TP (31.5% and 6.5%). Soluble COD and BOD removal efficiencies of both systems increased gradually since the start-up. After nine months of operation, above 90% removal of organic matters were observed. The treatment performances of the HSSF were better than that of the FWSF with regard to the removal of suspended solids and total COD at especially high temperatures. In FWSF systems, COD concentrations extremely exceeded the discharge limit values due to high concentrations of algae in spring months.The performance of the two systems was modelled using an artificial neural network-back-propagation algorithm. The ANN model was competent at providing reasonable match between the measured and the predicted concentrations of total COD (R = 0.90 for HSSF and R = 0.96 for FWSF), soluble COD (R = 0.90 for HSSF and R = 0.74 for FWSF) and total BOD (R = 0.94 for HSSF and R = 0.84 for FWSF) in the effluents of constructed wetlands.  相似文献   

19.
《Process Biochemistry》2007,42(2):193-198
A pilot-scale vertical submerged membrane bioreactor (VSMBR) with anoxic and oxic zones in one reactor was operated in an attempt to reduce the problems concerning effective removal of organic matter and nutrients from municipal wastewater. Source water with total chemical oxygen demand (TCOD)/total nitrogen (TN) ratio of 5.5 was treated at various temperatures (13–25 °C) over an interval of about 1 year. As a result, total suspended solid (TSS) and TCOD were removed by 100% and higher than 98%, respectively. Moreover, the average removal efficiencies of TN and total phosphorus (TP) were found to be 74% and 78% at 8 h-hydraulic retention time (HRT) and 60-days sludge retention time (SRT). Under these conditions, the specific removal rates (SRR) of TN and TP were found to be 0.093 kg N m−3 day−1 and 0.008 kg P m−3 day−1, and the daily production of excess sludge (DPES), 0.058 kg TSS day−1.  相似文献   

20.
A free-water surface wetland covering an area of 2800 m2 was operated from March 2002 to June 2004 for agricultural runoff treatment in the Dianchi Valley in China. In the wetland were grown Zizania Caduciflora Turez Hand-mazt and Phragmites australis (Cav.) Trin.ex Steud. The instantaneous inflow rate was measured and the integrated flux was recorded by an ultrasonic flow instrument all year round. The average inflow rate, hydraulic loading rate (HLR) and hydraulic retention time (HRT) were kept at 242 m3 d?1, 12.7 cm d?1 and 2.0 d, respectively. The annual average total phosphorus (TP) in the inflow was 0.87 mg L?1, and the corresponding removal efficiency was calculated to be 59.0%. Biannual plant uptake and removal by harvesting and seed transport was the main pathway for TP removal, while the influent TP load was 12.9 g m?2 year?1. Hydraulic retention time had a significant positive correlation with the removal of P (r2 = 0.88). Water temperature, inflow phosphorus load, inflow and hydraulic load rates were positively correlated with the removal of P. Inflow phosphorus concentrations were negatively correlated with the removal of P. It is shown that the free-water surface wetland was an effective and economical system for agricultural runoff treatment in lake regions.  相似文献   