首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

Left ventricular ejection fraction (LVEF) results from the combined action of longitudinal and circumferential contraction, radial thickening, and basal and apical rotation. The study of these parameters together may lead to an accurate assessment of the cardiac function.

Methods

Ninety healthy volunteers, categorized by gender and age (≤ 55 and?>? 55 years), were evaluated using two-dimensional speckle tracking echocardiography. Transversal views of the left ventricle (LV) were obtained to calculate circumferential strain and left ventricular twist, while three apical views were obtained to determine longitudinal strain (LS) and mitral annular plane systolic excursion (MAPSE). We established the integral myocardial function of the LV according to: 1. The Combined Deformation Parameter (CDP), which includes Deformation Product (DP) - Twist x LS (° x %) - and Deformation Index (DefI) -Twist / LS (° / %)-; and 2. the Torsion Index (TorI): Twist / MAPSE (° / cm).

Results

The mean age of our patients was 50.3?±?11.1 years. CDP did not vary with gender or age. The average DP was ??432?±?172 ° x %, and the average DefI was ??0.96?±?0.36 ° / %. DP provides information about myocardial function (normal, pseudonormal, depressed), and the DefI quotient indicates which component (s) is/are affected in cases of abnormality. TorI was higher in volunteers over 55 years (16.5?±?15.2 vs 13.1?±?5.0 °/cm, p?=?0.003), but did not vary with gender.

Conclusions

The proposed parameters integrate values of twisting and longitudinal shortening. They allow a complete physiological assessment of cardiac systolic function, and could be used for the early detection and characterization of its alteration.
  相似文献   

2.
A technique of modelling the left ventricle for the purpose of volume determination has been devised. Two-dimensional echocardiographic data from the apical four chamber and two chamber views are used to pattern the ventricle as a stack of elliptical discs. The method has been validated for an array of regular geometric shapes commonly associated with ventricular architecture. The relative advantages of this model are discussed.  相似文献   

3.
4.

Background

Conventional echocardiography is not sensitive enough to assess left ventricular (LV) dysfunction in hypertrophic cardiomyopathy (HCM) patients. This research attempts to find a new ultrasonic technology to better assess LV diastolic function, systolic function, and myocardial longitudinal and circumferential systolic strain of segments with different thicknesses in HCM patients.

Methods

This study included 50 patients with HCM and 40 healthy subjects as controls. The peak early and late mitral annulus diastolic velocities at six loci (Ea′ and Aa′, respectively) and the Ea′/Aa′ ratio were measured using real-time tri-plane echocardiography and quantitative tissue velocity imaging (RT-3PE-QTVI). The mean value of Ea′ at six loci (Em′) was obtained for the calculation of E/Em′ ratio. The LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), LV stroke volume (LVSV), and LV ejection fraction (LVEF) were measured using real-time three-dimensional echocardiography (RT-3DE). LV myocardial longitudinal peak systolic strain (LPSS) and circumferential peak systolic strain (CPSS) in the apical-middle-basal segments (LPSS-api, LPSS-mid, LPSS-bas; CPSS-api, CPSS-mid, and CPSS-bas, respectively) were obtained using a software for two-dimensional speckle tracking imaging (2D-STI). According to the different segmental thicknesses (STs) in each HCM patient, the values (LPSS and CPSS) of all the myocardial segments were categorized into three groups and the respective averages were computed.

Results

The Ea′, Aa′, and, Ea′/Aa’ ratio in HCM patients were lower than those in the controls (all p?<?0.001), while the E/Em′ ratio in HCM patients was higher than that in the controls (p?<?0.001). The LVEDV, LVSV, and LVEF were significantly lower in HCM patients than in controls (all p?<?0.001). In HCM patients, the LPSS-api, LPSS-mid, LPSS-bas, CPSS-api, CPSS-mid, and CPSS-bas and the LPSS and CPSS of LV segments with different thicknesses were all significantly reduced (all p?<?0.001).

Conclusions

In HCM patients, myocardial dysfunction was widespread not only in the obviously hypertrophic segments but also in the non-hypertrophic segments; the LV systolic and diastolic functions were damaged, even with a normal LVEF. LV diastolic dysfunction, systolic dysfunction, and myocardial deformation impairment in HCM patients can be sensitively revealed by RT-3PE-QTVI, RT-3DE, and 2D-STI.
  相似文献   

5.
目的 应用实时三维超声心动图(RT-3DE)研究房间隔缺损(ASD)患者行内科介入手术前后左、右室心肌收缩变化的相关关系.方法 应用RT-3DE技术对34例ASD患者术前、术后1周以及35例正常受检者(对照组)的左、右室舒张末期容量(LVEDV/RVEDV),左、右室收缩末期容量(LVESV/RVESV),左、右室每搏量(LVSV/RVSV)及左、右室射血分数(LVEF/RVEF)进行统计分析.结果 术前,ASD患者LVEDV、LVSV、LVEF均小于对照组(均P<0.05),RVEDV、RVESV、RVSV、RVEF均大于对照组(均P<0.05);术后1周内,ASD患者LVEDV、LVSV、LVEF均较术前增大(均P<0.05),RVEDV、RVSV、RVEF均较术前减小(均P<0.05);ASD患者术后的LVEDV、LVESV、LVSV、LVEF与对照组比较均无统计学意义(均P>0.05),而RVEDV、RVESV、RVSV均大于对照组(P<0.05);ASD患者术后左、右室的射血分数变化之间均无相关性.结论 行内科介入的ASD患者术后初期左、右室收缩功能即恢复到正常水平,术后左、右室射血分数的变化之间均无相关性.  相似文献   

6.
Two apparently different types of mechanisms have emerged to explain diastolic suction (DS), that property of the left ventricle (LV) that tends to cause it to refill itself during early diastole independent of any force from the left atrium (LA). By means of the first mechanism, DS depends on decreased elastance [e.g., the relaxation time constant (tau)] and, by the second, end-systolic volume (V(LVES)). We used wave-intensity analysis (WIA) to measure the total energy transported by the backward expansion wave (I(W-)) during LV relaxation in an attempt to reconcile these mechanisms. In six anesthetized, open-chest dogs, we measured aortic, LV (P(LV)), LA (P(LA)), and pericardial pressures and LV volume by orthogonal ultrasonic crystals. Mitral velocity was measured by Doppler echocardiography, and aortic velocity was measured by an ultrasonic flow probe. Heart rate was controlled by pacing, V(LVES) by volume loading, and tau by isoproterenol or esmolol administration. I(W-) was found to be inversely related to tau and V(LVES). Our measure of DS, the energy remaining after mitral valve opening, I(W-DS), was also found to be inversely related to tau and V(LVES) and was approximately 10% of the total "aspirating" energy generated by LV relaxation (i.e., I(W-)). The size of the Doppler (early filling) E wave depended on I(W-DS) in addition to I(W+), the energy associated with LA decompression. We conclude that the energy of the backward-going wave generated by the LV during relaxation depends on both the rate at which elastance decreases (i.e., tau) and V(LVES). WIA provides a new approach for assessing DS and reconciles those two previously proposed mechanisms. The E wave depends on DS in addition to LA decompression.  相似文献   

7.
Hypereosinophilic syndrome (HES) is a rare condition characterised by idiopathic eosinophilia with organ system involvement. The condition is far more common in males, with a typical onset in the third to sixth decade. Cardiac damage may result in the formation of a characteristic apical thrombus readily visualised on two-dimensional echocardiography. Cardiac involvement portends a less favourable prognosis as it can be complicated by acute embolic events and progressive development of restrictive cardiomyopathy, valvular dysfunction, and heart failure. In this case report, we describe a middle-aged gentleman with HES and characteristic apical thrombus identified on contrast echocardiography. Although the use of contrast agents for assessment of left ventricular thrombus is documented in the literature,1 this case illustrates the application of contrast echocardiography in the evaluation of eosinophilia. (Neth Heart J 2009;17:169–70.)  相似文献   

8.
A 55-year-old man was admitted to our hospital because of chest distress, associated with activity. Two-dimensional echocardiography (2DE) demonstrated a suspected trabeculation versus false tendon of the left ventricular apex cordis but not meeting the diagnostic criteria of noncompaction of the ventricular myocardium (NVM). Threedimensional echocardiography (3DE) revealed more prominent trabeculations and deeper intertrabecular recesses of the left ventricular apex, which were consistent with the diagnostic criteria of NVM. In contrast to 2DE, 3DE provides wide, pyramid-shaped datasets that encompass the entire left ventricle. (Neth Heart J 2009;17:208–10.)  相似文献   

9.
10.
Cardiac function may vary predictably along the 1-year scale. A circannual rhythm, more or less in phase is documented for 5 echocardiographic variables in clinically healthy Japanese adults.  相似文献   

11.
12.
The feasibility of blood-pool pinhole ECG gated SPECT was investigated in healthy mice to assess right and left ventricular function analysis. Anaesthetized (isoflurane 1-1.5%) adult CD1 mice (n=11) were analyzed after intravenous administration of 0.2 ml of 550 MBq of (99m)Tc human albumin. For blood-pool gated SPECT imaging, 48 ventral step and shoot projections with eight time bins per RR over 180 degrees with 64x64 word images were acquired with a small animal gamma camera equipped with a pinhole collimator of 12 cm in focal length and 1.5 mm in diameter. For appropriate segmentation of right and left ventricular volumes, a 4D Fourier analysis was performed after reconstruction and reorientation of blood-pool images with a voxel size of 0.55x0.55x0.55 mm(3). Average right and left ejection fractions were respectively 52+/-4.7% and 65+/-5.2%. Right end diastolic and end systolic volumes were significantly higher compared with the corresponding left ventricular volumes (P<0.0001 each). A linear correlation between right and left stroke volumes (r=0.9, P<0.0001) was obtained and right and left cardiac outputs were not significantly different 14.2+/-1.9 and 14.1+/-2 ml/min, respectively. To cite this article: C. Goetz et al., C. R. Biologies 331 (2008).  相似文献   

13.
14.

Background

Real-time perfusion (RTP) contrast echocardiography can be used during adenosine stress echocardiography (ASE) to evaluate myocardial ischemia. We compared two different types of RTP power modulation techniques, angiomode (AM) and high-resolution grayscale (HR), with99mTc-tetrofosmin single-photon emission computed tomography (SPECT) for the detection of myocardial ischemia.

Methods

Patients with known or suspected coronary artery disease (CAD), admitted to SPECT, were prospectively invited to participate. Patients underwent RTP imaging (SONOS 5500) using AM and HR during Sonovue® infusion, before and throughout the adenosine stress, also used for SPECT. Analysis of myocardial perfusion and wall motion by RTP-ASE were done for AM and HR at different time points, blinded to one another and to SPECT. Each segment was attributed to one of the three main coronary vessel areas of interest.

Results

In 50 patients, 150 coronary areas were analyzed by SPECT and RTP-ASE AM and HR. SPECT showed evidence of ischemia in 13 out of 50 patients. There was no significant difference between AM and HR in detecting ischemia (p = 0.08). The agreement for AM and HR, compared to SPECT, was 93% and 96%, with Kappa values of 0.67 and 0.75, respectively (p < 0.001).

Conclusion

There was no significant difference between AM and HR in correctly detecting myocardial ischemia as judged by SPECT. This suggests that different types of RTP modalities give comparable data during RTP-ASE in patients with known or suspected CAD.  相似文献   

15.
Background In three-dimensional echocardiography (3DE), individual endocardial trabeculae are not clearly visible necessitating left ventricular (LV) volumes to be measured by tracing the innermost endocardial contour. Ultrasound contrast agents aim to improve endocardial definition, but may delineate the outermost endocardial contour by filling up intertrabecular space. Although measurement reproducibility may benefit, there may be a significant influence on absolute LV volume measurements. Methods Twenty patients with a recent myocardial infarction and good ultrasound image quality underwent 3DE using the TomTec Freehand method before and during continuous intravenous contrast infusion. LV volumes were measured offline using TomTec Echo-Scan software. Results The use of contrast enhancement increased end-diastolic (110±35 vs. 144±53 ml; p<0.01) and end-systolic volume measurements (68±31 vs. 87±45 ml; p<0.01) significantly compared with non-contrast; the ejection fraction remained unchanged (40±13 vs. 41±14%, p=NS). Measurement reproducibility did not improve significantly, however. Conclusion Volumes measured by 3DE are significantly larger when ultrasound contrast is used. Possibly, intertrabecular space comprises a substantial part of the LV cavity. In the presence of an adequate apical acoustic window, ultrasound contrast does not improve LV volume measurement reproducibility. (Neth Heart J 2008;16:47-52.)  相似文献   

16.
The increasing number and proportion of aged individuals in the population warrants knowledge of normal physiological changes of left ventricular (LV) biomechanics with advancing age. LV twist describes the instantaneous circumferential motion of the apex with respect to the base of the heart and has an important role in LV ejection and filling. This study sought to investigate the biomechanics behind age-related changes in LV twist by determining a broad spectrum of LV rotation parameters in different age groups, using speckle tracking echocardiography (STE). The final study population consisted of 61 healthy volunteers (16-35 yr, n=25; 36-55 yr, n=23; 56-75 yr, n=13; 31 men). LV peak systolic rotation during the isovolumic contraction phase (Rot(early)), LV peak systolic rotation during ejection (Rot(max)), instantaneous LV peak systolic twist (Twist(max)), the time to Rot(early), Rot(max), and Twist(max), and rotational deformation delay (defined as the difference of time to basal Rot(max) and apical Rot(max)) were determined by STE using QLAB Advanced Quantification Software (version 6.0; Philips, Best, The Netherlands). With increasing age, apical Rot(max) (P<0.05), time to apical Rot(max) (P<0.01), and Twist(max) (P<0.01) increased, whereas basal Rot(early) (P<0.001), time to basal Rot(early) (P<0.01), and rotational deformation delay (P<0.05) decreased. Rotational deformation delay was significantly correlated to Twist(max) (R(2)=0.20, P<0.05). In conclusion, Twist(max) increased with aging, resulting from both increased apical Rot(max) and decreased rotational deformation delay between the apex and the base of the LV. This may explain the preservation of LV ejection fraction in the elderly.  相似文献   

17.
Assessment of left ventricular (LV) function in the catheterization laboratory is important to optimize treatment decisions and guide catheter-based local therapies. NOGA electromechanical mapping was developed to assess LV contraction during catheterization; however, quantitative analysis of its "local shortening" (LS) algorithm and direct comparison with conventional methods are lacking. We evaluated the accuracy of NOGA-based regional and global function by examining its ability to detect pharmacologically induced changes in contractility compared with echocardiography. Ten anesthetized pigs were paced to ensure a constant heart rate throughout the experiment. Electromechanical maps of the LV and short-axis echocardiograms were obtained 1) at baseline, 2) during intravenous dobutamine, and 3) after intravenous propranolol. NOGA LS and ejection fraction (EF) consistently increased under dobutamine and decreased after propranolol. NOGA LS and NOGA and echocardiography circumferential shortening correlated highly with one another (r > 0.80), as did NOGA EF with echocardiography EF (r = 0.92), although absolute values differed somewhat. Thus NOGA-based global and regional function correlates closely with echocardiography and is sensitive to changes in contractility, but, at the upper end of the scale, LV function is underestimated.  相似文献   

18.
19.

Background

Power Doppler (PD) has improved diagnostic capabilities of vascular sonography, mainly because it is independent from the angle of insonation. We evaluated this technique in a prospective comparison with conventional imaging, consisting in Duplex and Color Doppler, for the evaluation of Renal Artery (RA) stenosis.

Methods

Sensitivity, specificity and predictive values of PD and conventional imaging were assessed in a blinded fashion on eighteen patients, 9 with angiographic evidence of unilateral RA stenosis (hypertensive patients) and 9 with angiographically normal arteries (control group). PD images were interpreted with an angiography-like criteria.

Results

In the control group both techniques allowed correct visualization of 16 out of the 18 normal arteries (93% specificity). Only in five hypertensive patients RA stenosis was correctly identified with conventional technique (56% sensitivity and 86% negative predictive value); PD was successful in all hypertensive patients (100% sensitivity and negative predictive value), since the operators could obtain in each case of RA stenosis a sharp color signal of the whole vessel with a clear "minus" at the point of narrowing of the lumen. All results were statistically significant (p < 0.01).

Conclusions

This study demonstrates that PD is superior to conventional imaging, in terms of sensitivity and specificity, for the diagnosis of RA stenosis, because it allows a clear visualization of the whole stenotic vascular lumen. Especially if it is used in concert with the other sonographic techniques, PD can enable a more accurate imaging of renovascular disease with results that seem comparable to selective angiography.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号