首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A rapid and sensitive LC–MS/MS method for the determination of vardenafil and its major metabolite, N-desethylvardenafil, in human plasma using sildenafil as an internal standard was developed and validated. The analytes were extracted from 0.25-mL aliquots of human plasma by liquid–liquid extraction, using 1 mL of ethyl acetate. Chromatographic separation was carried on a Luna C18 column (50 mm × 2.0 mm, 3 μm) at 40 °C, with an isocratic mobile phase consisting of 10 mM ammonium acetate (pH 5.0) and acetonitrile (10:90, v/v), a flow rate of 0.2 mL/min, and a total run time of 2 min. Detection and quantification were performed using a mass spectrometer in the selected reaction-monitoring mode with positive electrospray ionization at m/z 489.1  151.2 for vardenafil, m/z 460.9  151.2 for N-desethylvardenafil, and m/z 475.3  100.1 for the internal standard (IS), respectively. This assay was linear over a concentration range of 0.5–200 ng/mL with a lower limit of quantification of 0.5 ng/mL for both vardenafil and N-desethylvardenafil. The coefficient of variation for the assay precision was <13.6%, and the accuracy was >93.1%. This method was successfully applied to a pharmacokinetic study after oral administration of vardenafil 20 mg tablet in Korean healthy male volunteers.  相似文献   

2.
This paper reports the development and validation of an assay for quantitation of bergenin in human plasma using liquid chromatography/tandem mass spectrometry (LC–MS/MS). Bergenin and the internal standard (I.S.), 5-bromo-2,4(1H,3H)-pyrimidinedione (5-BrU), were separated by reversed phase HPLC and quantitated by MS/MS using electrospray ionization (ESI) and multiple reaction monitoring (MRM) in the negative ion mode. The most intense [M?H]? MRM transition of bergenin at m/z 326.9  312.3 was used for quantitation and the transition at m/z 188.9  42.2 was used to monitor 5-BrU. Stability issues with bergenin required the addition of ascorbic acid to plasma samples prior to storage and analysis within 10 days storage at ?80 °C. The method was linear in the range 3–1000 ng/mL with intra- and inter-day precision of 3.94–5.96 and 1.62–8.31%, respectively, and accuracy <2.33%. The assay was successfully applied to a pharmacokinetic study in healthy volunteers after administration of a single 250 mg oral dose.  相似文献   

3.
A rapid and sensitive method using liquid chromatography–tandem mass spectrometry (LC–MS/MS) for enantiomeric determination of tramadol and its primary phase metabolite O-desmethyltramadol in human plasma has been developed. Tramadol hydrochloride – 13C, d3, was used as an isotopic labeled internal standard for quantification. The method involves a simple solid phase extraction. The analytes and internal standard were separated on Lux Cellulose-2 packed with cellulose tris(3-chloro-4-methylphenylcarbamate) using isocratic elution with hexane/isopropanol/diethylamine (90:10:0.1, v/v/v) at a flow rate of 1.3 mL/min. The APCI positive ionization mass spectrometry was used with multiple reaction monitoring of the transitions at m/z 264.2  58.2 for tramadol, m/z 250.1  58.2 for O-desmethyltramadol and m/z 268.2  58.2 for internal standard. Linearity was achieved between 1–800 ng/mL and 1–400 ng/mL (R2  0.999) for each enantiomer of tramadol and O-desmethyltramadol, respectively. Intra-day accuracies ranged among 98.2–102.8%, 97.1–109.1% and 97.4–102.9% at the lower, intermediate, and high concentration for all analytes, respectively. Inter-day accuracies ranged among 95.5–104.1%, 99.2–104.7%, and 94.2–105.6% at the lower, intermediate, and high concentration for all analytes, respectively. This assay was successfully used to determine the concentration of enantiomers of tramadol and O-desmethyltramadol in a pharmacogenetic study.  相似文献   

4.
Drug–drug interactions involving cytochrome P450 (CYP450s) are an important factor for evaluation of a new chemical entity (NCE) in drug development. To evaluate the potential inhibitory effects of a NCE on the pharmacokinetics of a cocktail of representative probes of CYP enzymes (midazolam for CYP3A4, tolbutamide for CYP2C9, omeprazole for CYP2C19 and dextromethorphan for CYP2D6) and the safety and tolerability of the NCE in the presence of probe substrates, a high throughput liquid chromatography/tandem mass spectrometry (LC–MS/MS) method was developed and validated for the simultaneous determination of tolbutamide, omeprazole, midazolam and dextromethorphan in human plasma using tolbutamide-d9, midazolam-d4, (±)-omeprazole-d3, and dextromethorphan-d3 as the internal standards (ISs). Human plasma samples of 50 μL were extracted by a simple protein-precipitation procedure and analyzed using a high performance liquid chromatography electrospray tandem mass spectrometer system. Reversed-phase HPLC separation was achieved with a Hypersil GOLD AQ column (50 mm × 4.6 mm, 5 μm). MS/MS detection was set at mass transitions of 271  172 m/z for tolbutamide, 346  198 m/z for omeprazole, 326  291 m/z for midazolam, 272  171 m/z for dextromethorphan, 280  172 m/z for tolbutamide-d9 (IS), 349  198 m/z for (±)-omeprazole-d3 (IS), 330  295 m/z for midazolam-d4 (IS), and 275  171 m/z for dextromethorphan-d3 (IS) in positive mode. The high throughput LC–MS/MS method was validated for accuracy, precision, sensitivity, stability, recovery, matrix effects, and calibration range. Acceptable intra-run and inter-run assay precision (<10%) and accuracy (<10%) were achieved over a linear range of 50–50,000 ng/mL for tolbutamide, 1–1000 ng/mL for omeprazole, 0.1–100 ng/mL for midazolam and 0.05–50 ng/mL for dextromethorphan in human plasma. Method robustness was demonstrated by the 100% pass rate of 24 incurred sample analysis runs and all of the 50 clinical study samples used for incurred sample reproducibility (ISR) test having met the acceptance criterion (%Diff within 20%). The overall ISR results for all compounds showed that over 95% of the samples had a %Diff of less than 10%. The method is simple, rapid and rugged, and has been applied successfully to sample analysis in support of a drug–drug interaction study.  相似文献   

5.
A sensitive, specific and selective method has been developed for the simultaneous determination of bisoprolol and hydrochlorothiazide in human plasma. The method employed a state of the art LC–MS/MS operated in the positive and negative ionization switching modes. A simple sample preparation step involving protein precipitation with acetonitrile has been optimized; the analytes and the internal standard moxifloxacin were separated on a Purosphere® STAR C8 column (125 mm × 4 mm, 5 μm). The mobile phase was an ammonium acetate solution (1 mM) with formic acid (0.2%): methanol and acetonitrile (65:17.5:17.5, v/v/v (%)), the flow rate was set at 0.65 mL/min. Bisoprolol and hydrochlorothiazide were ionized using ESI source prior to detection by Multiple Reaction Monitoring (MRM) mode while monitoring at the following transitions: positive m/z 326  116 for bisoprolol, negative m/z 296  269 and m/z 296  205 for hydrochlorothiazide. Linearity was demonstrated over the concentration range 0.10–30.0 (ng/mL) for bisoprolol and 1.00–80.00 ng/mL for hydrochlorothiazide. The limits of detection were 0.100 (ng/mL) for bisoprolol and 1.00 (ng/mL) for hydrochlorothiazide. The validated method was successfully applied to a pharmacokinetic study of 5 mg bisoprolol fumarate with 12.5 mg hydrochlorothiazide tablet in healthy volunteers.  相似文献   

6.
A simple, sensitive and high throughput liquid chromatography/positive-ion electrospray ionization mass spectrometry (LC–ESI-MS/MS) method has been developed for the simultaneous determination of valacyclovir and acyclovir in human plasma using fluconazole as internal standard (IS). The method involved solid phase extraction of the analytes and IS from 0.5 mL human plasma with no reconstitution and drying steps (direct injection of eluate). The chromatographic separation was achieved on a Gemini C18 analytical column using isocratic mobile phase, consisting of 0.1% formic acid and methanol (30:70 v/v), at a flow-rate of 0.8 mL/min. The precursor  product ion transition for valacyclovir (m/z 325.2  152.2), acyclovir (m/z 226.2  152.2) and IS (m/z 307.1  220.3) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) mode. The method was validated over the concentration range 5.0–1075 ng/mL and 47.6–10225 ng/mL for valacyclovir and acyclovir respectively. The mean recovery of valacyclovir (92.2%), acyclovir (84.2%) and IS (103.7%) from spiked plasma samples was consistent and reproducible. The bench top stability of valacyclovir and acyclovir was extensively evaluated in buffered and unbuffered plasma. It was successfully applied to a bioequivalence study in 41 healthy human subjects after oral administration of 1000 mg valacyclovir tablet formulation under fasting condition.  相似文献   

7.
A highly sensitive and rapid method for the analysis of isradipine in human plasma using liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) was developed. The procedure involves a simple liquid–liquid extraction of isradipine and amlodipine (IS, internal standard) with methyl-t-butyl ether after alkaline treatment and separation by RP-HPLC. Detection was performed by positive ion electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode, monitoring the transitions m/z 372.1  m/z 312.2 and m/z 408.8  m/z 237.9, for quantification of isradipine and IS, respectively. The standard calibration curves showed good linearity within the range of 10 to 5000 pg/mL (r2  0.9998). The lower limit of quantitation (LLOQ) was 10 pg/mL. The retention times of isradipine (0.81 min) and IS (0.65 min) suggested the potential for high throughput of the proposed method. In addition, no significant metabolic compounds were found to interfere with the analysis. This method offered good precision and accuracy and was successfully applied for the pharmacokinetic and bioequivalence studies of 5 mg of sustained-release isradipine in 24 healthy Korean volunteers.  相似文献   

8.
A highly efficient, selective and specific method for simultaneous quantitation of triprolidine and pseudoephedrine in human plasma by liquid chromatography–ion trap-tandem mass spectrometry coupled with electro spray ionization (LC–ESI-ion trap-tandem MS) has been validated and successfully applied to a clinical pharmacokinetic study. Both targeted compounds together with the internal standard (gabapentin) were extracted from the plasma by direct protein precipitation. Chromatographic separation was achieved on a C18 ACE® column (50.0 mm × 2.1 mm, 5 μm, Advance Chromatography Technologies, Aberdeen, UK), using an isocratic mobile phase, consisting of water, methanol and formic acid (55:45:0.5, v/v/v), at a flow-rate of 0.3 mL/min. The transition monitored (positive mode) was m/z 279.1  m/z 208.1 for triprolidine, m/z 165.9  m/z 148.0 for pseudoephedrine and m/z 172.0  m/z 154.0 for gabapentin (IS). This method had a chromatographic run time of 5.0 min and a linear calibration curves ranged from 0.2 to 20.0 ng/mL for triprolidine and 5.0–500.0 ng/mL for pseudoephedrine. The within- and between-batch accuracy and precision (expressed as coefficient of variation, %C.V.) evaluated at four quality control levels were within 94.3–106.3% and 1.0–9.6% respectively. The mean recoveries of triprolidine, pseudoephedrine and gabapentin were 93.6, 76.3 and 82.0% respectively. Stability of triprolidine and pseudoephedrine was assessed under different storage conditions. The validated method was successfully employed for the bioequivalence study of triprolidine and pseudoephedrine formulation in twenty six volunteers under fasting conditions.  相似文献   

9.
We present a simple, rapid, and sensitive liquid chromatography (LC)–tandem mass spectrometry (MS/MS) method for the simultaneous quantification of rosiglitazone and its two major metabolites via CYP2C8/9, N-desmethyl and p-hydroxy rosiglitazone, in human plasma. The procedure was developed and validated using rosiglitazone-d3 as the internal standard. Plasma samples (0.1 ml) were prepared using a simple deproteinization procedure with 0.2 ml of acetonitrile containing 40 ng/ml of rosiglitazone-d3. Chromatographic separation was carried out on a Luna C18 column (100 mm × 2.0 mm, 3-μm particle size) using an isocratic mobile phase consisting of a 60:40 (v/v) mixture of acetonitrile and 0.1% formic acid(aq). Each sample was run at 0.2 ml/min for a total run time of 2.5 min per sample. Detection and quantification were performed using a mass spectrometer in selected reaction-monitoring mode with positive electrospray ionization at m/z 358.1  135.1 for rosiglitazone, m/z 344.2  121.1 for N-desmethyl rosiglitazone, m/z 374.1  151.1 for p-hydroxy rosiglitazone, and m/z 361.1  138.1 for rosiglitazone-d3. The linear ranges of concentration for rosiglitazone, N-desmethyl rosiglitazone, and p-hydroxy rosiglitazone were 1–500, 1–150, and 1–25 ng/ml, respectively, with a lower limit of quantification of 1 ng/ml for all analytes. The coefficient of variation for assay precision was less than 14.4%, and the accuracy was 93.3–112.3%. No relevant cross-talk and matrix effect were observed. This method was successfully applied to a pharmacokinetic study after oral administration of a 4-mg rosiglitazone tablet to healthy male Korean volunteers.  相似文献   

10.
A rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the determination of picamilon concentration in human plasma. Picamilon was extracted from human plasma by protein precipitation. High performance liquid chromatography separation was performed on a Venusil ASB C18 column with a mobile phase consisting of methanol ?10 mM ammonium acetate–formic acid (55:45:01, v/v/v) at a flow rate of 0.65 ml/min. Acquisition of mass spectrometric data was performed in selected reaction monitoring mode, using the transitions of m/z 209.0  m/z (78.0 + 106.0) for picamilon and m/z 152.0  m/z (93.0 + 110.0) for paracetamol (internal standard). The method was linear in the concentration range of 1.00–5000 ng/ml for the analyte. The lower limit of quantification was 1.00 ng/ml. The intra- and inter-assay precision were below 13.5%, and the accuracy was between 99.6% and 101.6%. The method was successfully applied to characterize the pharmacokinetic profiles of picamilon in healthy volunteers. This validated LC–MS/MS method was selective and rapid, and is suitable for the pharmacokinetic study of picamilon in humans.  相似文献   

11.
A sensitive and selective liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed to determine the concentration of eptifibatide in human plasma. Following protein precipitation, the analyte was separated on a reversed-phase C18 column. Acetonitrile:5 mM ammonium acetate:acetic acid (30:70:0.1, v/v/v) was used at a flow-rate of 0.5 mL/min with the isocratic mobile phase. An API 4000 tandem mass spectrometer equipped with a Turbo IonSpray ionization source was used as the detector and was operated in the positive ion mode. “Truncated” multiple reaction monitoring using the transition of m/z 832.6  m/z 832.6 and m/z 931.3  m/z 931.3 was performed to quantify eptifibatide and the internal standard (EPM-05), respectively. The method had a lower limit of quantification of 4.61 ng/mL for eptifibatide. The calibration curve was demonstrated to be linear over the concentration range of 4.61 ? 2770 ng/mL. The intra- and inter-day precisions were less than 10.5% for each QC level, and the inter-day relative errors were 2.0%, 5.6%, and 2.8% for 9.22, 184, and 2490 ng/mL, respectively. The validated method was successfully applied to the quantification of eptifibatide concentration in human plasma after intravenous (i.v.) administration of a 270-μg/kg bolus of eptifibatide and i.v. administration of eptifibatide at a constant rate of infusion of 2 μg/(kg min) for 18 h in order to evaluate the pharmacokinetics.  相似文献   

12.
Vincristine is a natural vinca alkaloid widely used in paediatric cancer treatment. Vincristine pharmacokinetics has been already studied, but few data are available in paediatric populations. A sensitive and specific liquid chromatography–tandem mass spectrometry (LC/MS/MS) method was developed for the quantification of vincristine in plasma in order to investigate pharmacokinetics in a paediatric population. Two hundred microliters of plasma was added to vinblastine, used as internal standard. Chromatographic separation was achieved on a C8 HPLC column (Phenomenex Luna 50 mm × 2.0 mm, 3.0 μm) with a mobile phase gradient at a flow rate of 0.2 ml/min. Quantification was performed using the transition of 825.4  765.4 (m/z) for vincristine and 811.4  751.4 (m/z) for vinblastine. Chromatographic separation was achieved in 8 min. The limit of quantification was 0.25 ng/ml with a precision of 10.2% and an accuracy of 99.6%. The calibration curve was linear up to 50.0 ng/ml. Intra-day precision and accuracy ranged from 6.3% to 10% and from 91.9% to 100.8%, respectively. Inter-assay precision and accuracy ranged from 3.8% to 9.7% and from 93.5% to 100.5%, respectively. No significant matrix effect was observed for vincristine. A rapid, specific and sensitive LC/MS/MS method for quantification of vincristine in human plasma was developed and is now successfully applied for pharmacokinetic studies in paediatric patients.  相似文献   

13.
A rapid and sensitive bioassay based on liquid chromatography–tandem mass spectrometry (LC–MS/MS) for the simultaneous determination of four isomeric escin saponins (escin Ia, escin Ib, isoescin Ia and isoescin Ib) in human plasma has been developed and validated. Sample preparation of plasma after addition of telmisartan as internal standard (I.S.) involved solid-phase extraction (SPE) on C18 cartridges. Separation was based on reversed phase chromatography using gradient elution with methanol–acetonitrile (50:50, v/v) and 10 mM ammonium acetate solution (pH 6.8). MS/MS detection in the positive ion mode used multiple reaction monitoring of the transition at m/z 1113.8  807.6. Stability issues with the four saponins required the addition of formic acid to plasma samples prior to storage at ?80 °C and analysis within 30 days. The method was linear at concentrations up to 10 ng/mL with correlation coefficients > 0.996 for all analytes. The lower limit of quantitation (LLOQ) for all four saponins was 33 pg/mL. Intra- and inter-day precisions (as relative standard deviation) were all <15% and accuracies (as relative error) in the range ?5.3% to 6.1%. The method was successfully applied to a pharmacokinetic study of escins in healthy volunteers after oral administration of sodium aescinate tablets containing 60 mg escin saponins.  相似文献   

14.
A highly sensitive, specific and evaporation free SPE extraction, LC–MS/MS method has been developed for the estimation of trospium in human plasma using trospium-d8 as an internal standard (IS). The analyte was separated using isocratic mobile phase on reverse phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+] cations, m/z 392–164 for trospium and m/z 400–172 for the IS. The total run time was 3.50 min and the elution of trospium and trospium-d8 (IS) occurred at 2.8 min. The developed method was validated in human plasma with a lower limit of quantification of 0.05 ng/mL. A linear response function was established for the range of concentrations 0.05–10 ng/mL (r > 0.998) for trospium in human plasma. The intra- and inter-day precision values for trospium met the acceptance as per FDA guidelines. Trospium was stable in the battery of stability studies viz., bench-top, auto-sampler, dry extracts and freeze/thaw cycles. The developed assay method was applied to an oral pharmacokinetic study in humans.  相似文献   

15.
A selective, sensitive and high throughput liquid chromatography–tandem mass spectrometry (LC–ESI-MS/MS) method has been developed and validated for the chromatographic separation and quantitation of (E)-entacapone and (Z)-entacapone in human plasma. Sample clean-up involved liquid–liquid extraction (LLE) of both the isomers and carbamazepine used as internal standard from 500 μL of human plasma. Both the analytes were chromatographically separated with a resolution factor of 3.0 on a Gemini C18 (50 mm × 4.6 mm, 5 μm particle size) analytical column using 1% formic acid and methanol (50:50, v/v) as the mobile phase. The selectivity factor (α) of the column for the separation was 2.0, based on the capacity factors of 2.6 and 1.3 for (E)- and (Z)-isomers respectively. The parent  product ion transitions for both the isomers (m/z 306.1  233.0) and IS (m/z 237.3  194.2) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) and positive ion mode. The method was validated over the concentration range of 24.3–6076 ng/mL and 23.8–5960 ng/mL for (E)-entacapone and (Z)-entacapone respectively. Matrix effect was assessed by post-column analyte infusion experiment and the process/extraction efficiency found was 94.3% and 89.3% for (E)- and (Z)-isomers respectively. The method was successfully applied to a pivotal bioequivalence study in 36 healthy human subjects after oral administration of 200 mg (E)-entacapone tablet formulation under fasting conditions.  相似文献   

16.
A highly sensitive and selective HPLC–MS/MS method is presented for the quantitative determination of tiloronoxim and its metabolite tilorone in human blood. An aliquot of 200 μl human blood was extracted with a mixture of chloroform/ethyl ether (1/2, v/v), using metoprolol as the internal standard (the IS). Separation was achieved on an Xterra MS C18 column (50 mm × 2.1 mm, 5 μm) with a gradient mobile phase of methanol/water containing 15 mM ammonium bicarbonate (pH 10.5). Detection was performed using positive MRM mode on a TurboIonSpray source. The mass transitions monitored were m/z 426.3  100.0, m/z 411.3  100.0 and m/z 268.3  116.1 for tiloronoxim, tilorone and the IS, respectively. The method was fully validated using total error theory, which is based on β-expectation tolerance intervals and include trueness and intermediate precision. The method was found to be accurate over a concentration range of 1–100 ng/ml for both compounds. The measurement uncertainty based on β-expectation tolerance intervals was assessed at each concentration level of the validation standards. This method was successively applied to a pharmacokinetic study of tiloronoxim in healthy volunteers.  相似文献   

17.
A sensitive and specific liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the quantification of cyclosporine A (CyA) and the identification of its metabolites in rat urine and feces. The analytes were extracted from waste samples via liquid–liquid extraction. A Turboionspray source was used as a detector. It was operated in a positive ion mode with transitions of m/z 1225  m/z 1112 for CyA and in a selected multiple reactions monitoring (MRM) mode with transitions of m/z 1239  m/z 1099 for the internal standard (cyclosporine D, CyD). Linear calibration curves were obtained for CyA concentration ranges of 12.5–250 ng mL?1 in urine and 2.5–375 ng mg?1 in feces. The intra- and inter-day precision values (relative standard deviation) obtained were less than 8%, and the accuracy was within ±15% for each of the analytes. Extraction recoveries of CyA and CyD were both over 80%. The identification of the metabolites and elucidation of their structure were performed on the basis of their retention times and mass spectrometry fragmentation behaviors. A total of seven metabolites in rat feces were identified as dimethyl CyA, hydroxy CyA, and dihydroxy CyA after the oral administration of cyclosporine A-Eudragit® S100 nanoparticles (CyA-NP). Six of these metabolites were also detected in rat urine. A possible metabolic pathway was also proposed. The newly developed method was proven to be sensitive, simple, reproducible, and suitable for the rapid determination of CyA. It was successfully employed to study the excretion of CyA in rats and could be used to better understand the in vivo metabolism of CyA-NP, a potentially effective nanoparticle system.  相似文献   

18.
In the human body, the catecholamine norepinephrine is mainly metabolized to 3,4-dihydroxyphenylglycol (DHPG) which therefore serves as an important biomarker for norepinephrine's metabolism. Most data on DHPG concentrations in human plasma and urine has been generated by using HPLC-ECD or GC–MS technologies. Here, we describe a stable-isotope dilution GC–MS/MS method for the quantitative determination of DHPG in human urine using trideutero-DHPG (d3-DHPG) as internal standard and a two-step derivatization process with pentafluorobenzyl bromide (PFB-Br) and N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA). Two pentafluorobenzyl (PFB) trimethylsilyl (TMS) derivatives were obtained and identified, i.e., two isomeric DHPG-PFB-(TMS)3 derivatives and the later eluting DHPG-tetrafluorobenzyl-(TMS)2 derivative, i.e., DHPG-TFB-(TMS)2. To our knowledge the DHPG-TFB-(TMS)2 derivative and the underlying reaction have not been reported previously. In this reaction both vicinal aromatic hydroxyl groups of DHPG react with PFB-Br to form a heterocyclic seven-membered [1,4]dioxepin compound. The DHPG-TFB-(TMS)2 derivative was used for quantitative GC–MS/MS analysis in the electron-capturing negative-ion chemical ionization mode by selected-reaction monitoring of m/z 351 from m/z 401 for DHPG and of m/z 352 from m/z 404 for d3-DHPG. Validation experiments on human urine samples spiked with DHPG in a narrow (0–33 nM) and a wide range (0–901 nM) revealed high recovery (86–104%) and low imprecision (RSD; 0.01–2.8%). LOD and relative LLOQ (rLLOQ) values of the method for DHPG were determined to be 76 amol and 9.4%, respectively. In urine of 28 patients suffering from chronic inflammatory rheumatic diseases, DHPG was measured at a mean concentration of 238 nM (38.3 μg/g creatinine). The DHPG concentration in the respective control group of 40 healthy subjects was measured to be 328 nM (39.2 μg/g creatinine). Given the unique derivatization reaction and collision-induced dissociation, and the straightforwardness the present method is highly specific, accurate, precise, and should be useful in clinical settings.  相似文献   

19.
A novel validated liquid chromatography–tandem mass spectrometry (LC–MS/MS) procedure was developed and fully validated for the simultaneous determination of nicotine-N-β-d-glucuronide, cotinine-N-oxide, trans-3-hydroxycotinine, norcotinine, trans-nicotine-1′-oxide, cotinine, nornicotine, nicotine, anatabine, anabasine and cotinine-N-β-d-glucuronide in human plasma or urine. Target analytes and corresponding deuterated internal standards were extracted by solid-phase extraction and analyzed by LC–MS/MS with electrospray ionization (ESI) using multiple reaction monitoring (MRM) data acquisition. Calibration curves were linear over the selected concentration ranges for each analyte, with calculated coefficients of determination (R2) of greater than 0.99. The total extraction recovery (%) was concentration dependent and ranged between 52–88% in plasma and 51–118% in urine. The limits of quantification for all analytes in plasma and urine were 1.0 ng/mL and 2.5 ng/mL, respectively, with the exception of cotinine-N-β-d-glucuronide, which was 50 ng/mL. Intra-day and inter-day imprecision were ≤14% and ≤17%, respectively. Matrix effect (%) was sufficiently minimized to ≤19% for both matrices using the described sample preparation and extraction methods. The target analytes were stable in both matrices for at least 3 freeze–thaw cycles, 24 h at room temperature, 24 h in the refrigerator (4 °C) and 1 week in the freezer (?20 °C). Reconstituted plasma and urine extracts were stable for at least 72 h storage in the liquid chromatography autosampler at 4 °C. The plasma procedure has been successfully applied in the quantitative determination of selected analytes in samples collected from nicotine-abstinent human participants as part of a pharmacokinetic study investigating biomarkers of nicotine use in plasma following controlled low dose (7 mg) transdermal nicotine delivery. Nicotine, cotinine, trans-3-hydroxycotinine and trans-nicotine-1′-oxide were detected in the particular sample presented herein. The urine procedure has been used to facilitate the monitoring of unauthorized tobacco use by clinical study participants at the time of physical examination (before enrollment) and on the pharmacokinetic study day.  相似文献   

20.
A liquid chromatography–electrospray ionization tandem mass spectrometry (HPLC–ESI-MS/MS) method for the determination of andrographolide in human plasma was established. Dehydroandrographolide was used as the internal standard (I.S.). The plasma samples were deproteinized with methanol and separated on a Hanbon C18 column with a mobile phase of methanol–water (70:30, v/v). HPLC–ESI-MS/MS was performed in the selected ion monitoring (SIM) mode using target ions at [M?H2O–H]?, m/z 331.1 for andrographolide and [M?H]?, m/z 331.1 for the I.S. Calibration curve was linear over the range of 1.0–150.0 ng/mL. The chromatographic separation was achieved in less than 6.5 min. The lower limits of quantification (LLOQ) was 1.0 ng/mL. The intra and inter-run precisions were less than 6.95 and 7.22%, respectively. The method was successfully applied to determine the plasma concentrations of andrographolide in Chinese volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号