首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A reliable and sensitive liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) confirmation method has been developed for the simultaneous determination of chloramphenicol (CAP), thiamphenicol (TAP), florfenicol (FF), and florfenicol amine (FFA) in chicken muscle. Samples were extracted with basic ethyl acetate, defatted with hexane, and cleaned up on Oasis MCX cartridges. LC separation was achieved on a XTerra C(18) column with gradient elution using a mobile phase composed of acetonitrile and water at a flow rate of 0.20 mL/min. The analysis was carried out on a triple-quadrupole tandem mass spectrometer in the multiple reaction monitoring (MRM) mode via electrospray interface operated in the positive and negative ionization modes, with deuterated chloramphenicol-d5 (d(5)-CAP) as the internal standard. The method validation was performed according to the criteria of Commission Decision 2002/657/EC. Four identification points were obtained for each analyte with one precursor ion and two product ions. Limits of detection (LODs) were 0.1 microg/kg for CAP, 0.2 microg/kg for FF and 1 microg/kg for TAP and FFA in chicken muscle. Linear calibration curves were obtained over concentration ranges of 0.3-20 microg/kg for CAP, 0.5-20 microg/kg for FF and 3-100 microg/kg for TAP and FFA in tissues. Mean recoveries of the 4 analytes ranged from 95.1% to 107.3%, with the corresponding intra- and inter-day variation (relative standard deviation, R.S.D.) less than 10.9% and 10.6%, respectively. The decision limit (CCalpha) and detection capability (CCbeta) of the method were also reported.  相似文献   

2.
A specific, sensitive and widely applicable reversed-phase high-performance liquid chromatography with fluorescence detection (RP-HPLC-FLD) method was developed for the simultaneous determination of thiamphenicol (TAP), florfenicol (FF) and florfenicol amine (FFA) in eggs. Samples were extracted with ethyl acetate-acetonitrile-ammonium hydroxide (49:49:2, v/v), defatted with hexane, followed by RP-HPLC-FLD determination. Liquid chromatography was performed on a 5 μm LiChrospher C(18) column using a mobile phase composed of acetonitrile (A), 0.01 M sodium dihydrogen phosphate containing 0.005 M sodium dodecyl sulfate and 0.1% triethylamine, adjusted to pH 4.8 by 85% phosphoric acid (B) (A:B, 35:65 v/v), at a flow rate of 1.0 mL/min. The fluorescence detector of HPLC was set at 224 nm for excitation wavelength and 290 nm for emission wavelength. Limits of detection (LODs) were 1.5 μg/kg for TAP and FF, 0.5 μg/kg for FFA in eggs; limits of quantitation (LOQs) were 5 μg/kg for TAP and FF, 2 μg/kg for FFA in eggs. Linear calibration curves were obtained over concentration ranges of 0.025-5.0 μg/mL for TAP with determination coefficients of 0.9997, 0.01-10.0 μg/mL for FF with determination coefficients of 0.9997 and 0.0025-2.50 μg/mL for FFA with determination coefficients of 0.9998, respectively. The recovery values ranged from 86.4% to 93.8% for TAP, 87.4% to 92.3% for FF and from 89.0% to 95.2% for FFA. The corresponding intra-day and inter-day variation (relative standard deviation, R.S.D.) found to be less than 6.7% and 10.8%, respectively.  相似文献   

3.
A rapid and sensitive liquid chromatography–electrospray ionization-tandem mass spectrometry (LC–ESI-MS/MS) method to quantify thiamphenicol (TAP), florfenicol (FF), and florfenicol amine (FFA) in swine muscle is described. An immunoaffinity chromatography (IAC) column based on polyclonal antibodies and protein A-sepharose CL 4B was used to clean-up extracted samples. IAC optimized conditions were found that allowed the IAC to be reused for selective binding of TAP, FF, and FFA. The dynamic column capacity was more than 512 ng/mL of gel after being used for 15 cycles. From fortified swine muscle samples at levels of 0.4–50 ng/g, the average recoveries were 85.2–98.9% with intra- and inter-day variations less than 9.8% and 12.4%, respectively. The limit of quantitation ranged from 0.4 to 4.0 μg/kg.  相似文献   

4.
HPLC–MS/MS methods for the determination of a Hepatitis C NS3/NS4 protease inhibitor (MK-7009) in human plasma and Tween-treated urine were developed and validated over the concentration range 1–1000 ng/mL and 0.2–100 μg/mL respectively. A stable isotope labeled internal standard (ISTD), D4-MK-7009, was employed. Analytes were chromatographed by reversed phase HPLC and quantified by an MS/MS system. Electrospray ionization in the positive mode was employed. Multiple reaction monitoring of the precursor to product ion pairs m/z 758.6  637.4 MK-7009 and m/z 762.5  637.4 ISTD was used for quantitation. Analyte and internal standard were extracted from 250 μL of plasma using an automated 96-well liquid–liquid extraction. Plasma pH adjustment prior to extraction minimized ionization suppression in plasma samples from patients with Hepatitis C. The urine method involved direct dilution in the 96-well format of 0.020 mL Tween-treated urine. These methods have supported several clinical studies. Incurred plasma sample reanalysis demonstrated adequate assay reproducibility and ruggedness.  相似文献   

5.
A high throughput and specific method using ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) was developed for the simultaneous determination of diltiazem and its two metabolite (N-desmethyldiltiazem and O-desacetyldiltiazem) in human plasma. A one-step liquid–liquid extraction (LLE) with methyl-t-butyl ether (MTBE) involved for the extraction of diltiazem (DLTZ), metabolites (DMeD and DAcD) and internal standard. Analytes were chromatographed on a ACQUITY UPLC? BEH C18 column (100 mm × 2.1 mm, i.d., 1.7 μm) with isocratic elution at a flow rate of 0.2 mL/min using 10 mM ammonium acetate buffer–acetonitrile (25:75, v/v). The Quattro Premier XE LC–MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. Using 300 μL plasma, the method was validated over the concentration range 0.48–639.9 ng/mL for DLTZ and 0.24–320.1 for DMeD and 0.24–320.7 ng/mL for DAcD, with a lower limit of quantification of 0.48 ng/mL for DLTZ and 0.24 ng/mL for metabolites. The intra- and inter-day precision and accuracy were within 10.0%. The recovery was 77.4%, 76.0%, 74.5% and 74.1% for DLTZ, DMeD, DAcD and Ziprasidone, respectively. Total run time was 2.0 min only.  相似文献   

6.
A reversed-phase liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) method was developed and validated for simultaneous determination of ABT-888 and its major metabolite (M8) in human plasma. Sample preparation involved a liquid–liquid extraction by the addition of 0.25 ml of plasma with 10 μl of 1 M NaOH and 1.0 ml ethyl acetate containing 50 ng/ml of the internal standard zileuton. The analytes were separated on a Waters XBridge C18 column using a gradient mobile phase consisting of methanol/water containing 0.45% formic acid at the flow rate of 0.2 ml/min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the ABT-888 and M8 concentration ranges of 1–2000 ng/ml in human plasma. The lower limits of quantitation (LLOQ) were 1 ng/ml for both ABT-888 and M8 in human plasma. The accuracy and within- and between-day precisions were within the generally accepted criteria for bioanalytical method (<15%). This method was successfully employed to characterize the plasma concentration–time profile of ABT-888 after its oral administration in cancer patients.  相似文献   

7.
A kinetic study of atosiban was conducted following repeated intravenous administration in Wistar rats. Sample analysis was performed using liquid chromatography–tandem mass spectrometry (LC–MS/MS) following full validation of an in-house method. Eptifibatide, a cyclic peptide, was used as an internal standard (IS). The analyte and internal standard were extracted using solid phase extraction (SPE) method. Chromatographic separation was carried out using an ACE C18 5 μm 50 mm × 4.6 mm column with gradient elution. Mass spectrometric detection was performed using TSQ Quantum ultra AM. The lower limit of quantification was 0.01 μg/ml when 100 μl rat plasma was used. Plasma concentrations of atosiban were measured at 0 (pre-dose), 2, 15, 30, 45, 60, 120 min at the dosage levels of 0.125 mg/kg (low dose), 0.250 mg/kg (mid dose), and 0.500 mg/kg (high dose), respectively. Atosiban plasma concentration measured at Day 1 showed mean peak atosiban concentration (Cmax) 0.40, 0.57, 1.95 μg/ml for low, mid and high dose treated animals and mean peak concentration on Day 28 was 0.41, 0.88, 1.31 μg/ml on Day 28 for low, mid and high dose treated animals.  相似文献   

8.
High-performance liquid chromatography, coupled to tandem mass spectrometry (HPLC–MS/MS) has been established as the method of choice for the sensitive and simultaneous determination of different folates in a particular matrix, especially when only minute quantities of material are available. Using a previously developed and validated HPLC–MS/MS method as a starting point, we here report on the development and validation of an ultra-performance liquid chromatography (UPLC–MS/MS) method for analysis of folates in rice, which allows higher throughput and better resolution. UPLC was performed under gradient conditions on an Acquity HSS T3 column, followed by tandem mass spectrometry detection. The method was validated based on linearity, sensitivity, precision, accuracy and matrix effects. The limits of detection and the lower limits of quantification varied between 0.06 and 0.45 μg/100 g and 0.12 and 0.91 μg/100 g, respectively. Two linear calibration curves were established, one for the low and the other for the high concentration range. Analysis of the distribution and levels of folates in wild-type and folate-biofortified rice showed up to 50-fold enrichment in biofortified rice, with total folate levels of up to 900 μg/100 g rice. This is the first successful implementation of a UPLC method for the rapid and sensitive quantitative determination of folates in plant material.  相似文献   

9.
To eliminate the diastereomer interference on Telcagepant (MK-0974) determination during clinical study support, on-line high turbulent-flow liquid chromatography (HTLC) methods, HTLC-A and HTLC-B that covered dynamic range of 0.5–500 nM and 5–5000 nM, respectively, were developed. To meet the requirement of rapid assay transfer among multiple laboratories and analysts, a solid-phase extraction (SPE) assay was derived from the existing HTLC-B assay under the same dynamic range. The on-line HTLC assays were achieved through direct injection of plasma samples, extraction of analyte with a Cohesive C18 column (50 mm × 0.5 mm, 50 μm), followed by HPLC separation on a FluoPhase RP column (100 mm × 2.1 mm, 5 μm) and MS/MS detection. The off-line SPE assay used Waters Oasis®HLB μElution plate to extract the analytes from plasma matrix before injecting on a FluoPhase RP column (150 mm × 2.1 mm, 5 μm) for LC–MS/MS analysis. Under both on-line and off-line assay conditions, the diastereomer 1c was chromatographically separated from MK-0974. Cross-validation with the pooled samples demonstrated that both on-line and off-line assays provided comparable data with a difference of <2.6%. The assays were proved to be specific, accurate and reliable, and have been used to support multiple clinical studies. The pros and cons of on-line and off-line assays with regard to man power involved in sample preparation, total analysis time, carryover, cost efficiency, and the requirement for assay transfer are discussed.  相似文献   

10.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was validated and applied to the in vitro determination of 4-[(hydroxyimino)methyl]-1-octylpyridinium cation (4-PAO), which can penetrate the blood–brain barrier and reactivate acetylcholinesterase (AChE) inhibited by alkylphosphonate in the brain, liver, lung, and kidney. The limit of detection (LOD) was 0.235 μg cation/g wet weight, and the quantification range and linearity of the calibration curve extended over a range of 0.470–941 μg cation/g wet weight. For the proof of applicability, when 4-PAO was administrated intravenously via the rat tail vein at 10% LD50, we were able to quantify the 4-PAO concentration in the tissues: brain 7.60 ± 1.32 μg cation/g wet weight (mean ± SD, n = 5), liver 26.8 ± 2.82 μg cation/g, lung 76.4 ± 24.9 μg cation/g, and kidney 638 ± 266 μg cation/g. In addition, the methods for 4-[(hydroxyimino)methyl]-1-decylpyridinium bromide (4-PAD) and 4-[(hydroxyimino)methyl]-1-(2-phenylethyl) pyridinium bromide (4-PAPE) were partly validated referring to the findings of the 4-PAO full validation. Thus, the LC-MS/MS method described in this study can be useful for quantification of pyridinium aldoxime methiodide (PAM)-type oximes in biological samples.  相似文献   

11.
A method based on the on-line turbulent-flow chromatography and fast high-performance liquid chromatography/mass spectrometry (TFC–LC/MS) was developed for sensitive and high throughput pharmacokinetic study of traditional Chinese medicines (TCMs). In this method, an on-line extraction column (Waters Oasis HLB) and a fast HPLC column with sub-2 μm particle size (Agilent Zorbax StableBond-C18, 4.6 mm × 50 mm, 1.8 μm) in a column-switching set-up were utilized. HLB is a reversed-phase extraction column with hydrophilic–lipophilic balanced copolymer (2.1 mm × 20 mm, 25 μm particle size), which will exhibit some turbulent-flow properties at a high-flow rate. The method combines the speed and robustness of turbulent-flow extraction and the sensitivity and separation efficiency of fast HPLC–MS to analyze multiple and trace constituents of TCMs in plasma matrix. This method was successfully applied for pharmacokinetic study of verticine, verticinone and isoverticine, the chemical markers of Fritillaria thunbergii, after oral administration of total steroidal alkaloids extract of F. thunbergii to rats. Each plasma sample was analyzed within 7 min. The method demonstrated good linearity (R > 0.999) ranged from 0.505 to 96.0 ng/mL with satisfactory accuracy and precision, and the lower limit of quantifications of verticine, verticinone and isoverticine were estimated to be 0.120, 0.595 and 0.505 ng/mL, respectively. These results indicate that the proposed method is fast, sensitive, and feasible for pharmacokinetic study of TCMs.  相似文献   

12.
A sensitive and specific method using ultra performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) was developed for the determination of levetiracetam (LEV) in plasma of neonates. A plasma aliquot of 50 μl was deproteinized by addition of 500 μl methanol which contained 5 μg/ml UCB 17025 as an internal standard. After centrifugation, 50 μl of supernatant was diluted with 1000 μl of 0.1% formic acid–10 mM ammonium formate in water (pH 3.5) (mobile phase solution A) and 2 μl was injected onto the UPLC-system. Compounds were separated on a Acquity UPLC BEH C18 2.1 mm × 100 mm column using gradient elution with mobile phase solution A and 0.1% formic acid in methanol (mobile phase solution B) with a flow rate of 0.4 ml/min and a total runtime of 4.0 min. LEV and the internal standard were detected using positive ion electrospray ionization followed by tandem mass spectrometry (ESI-MS/MS). The assay allowed quantification of LEV plasma concentrations in the range from 0.5 μg/ml to 150 μg/ml. Inter-assay inaccuracy was within ±2.7% and inter-assay precision was less than 4.5%. Matrix effects were minor: the recovery of LEV was between 97.7% and 100%. The developed method required minimal sample preparation and less plasma sample volume compared to earlier published LC–MS/MS methods. The method was successfully applied in a clinical pharmacokinetic study in which neonates received intravenous administrations of LEV for the treatment of neonatal seizures.  相似文献   

13.
In the present work, a simple and high sensitive method based on hollow fiber liquid phase microextraction (HF-LPME) was developed followed by high performance liquid chromatography (HPLC) for determination of ultra-trace amounts of Se(IV) after derivatization in biological and natural water samples. Se(IV) was complexed with o-phenylenediamine to form piazselenol. The formed piazselenol was extracted into 20 μL of 1-octanol located in the lumen of a hollow fiber and the solution was injected into HPLC-UV for analysis. Using the Taguchi method, an orthogonal array design (OAD), OA16 (45) was employed to optimize the HF-LPME of piazselenol. The effect of five experimental factors (each factor at four levels) including the volume of the organic phase, extraction time, pH of the solution, stirring rate and ionic strength on the extraction efficiency of piazselenol was studied and optimized. The maximum extraction efficiency of piazselenol was obtained at 20 μL of 1-octanol as the extracting solvent, 30 min extraction time, pH 2, stirring rate of 500 rpm and 30% (w/v) NaCl. Under the optimum conditions, preconcentration factors up to 130 were achieved and the relative standard deviation (%RSD) of the method was <3.7% for different concentrations of Se(IV). The calibration curves were obtained in the ranges of 0.2–100 and 0.05–10 μg L?1 for the 11 and 50 mL of the sample volumes with reasonable linearity, respectively (r2 > 0.995). The limits of detection (LOD) were 0.1 and 0.02 μg L?1 for the 11 and 50 mL sample volumes, respectively (S/N = 3). Finally, the applicability of the proposed method was evaluated by the extraction and determination of Se(IV) in the plasma, urine and water samples.  相似文献   

14.
A rapid and selective method for simultaneous determination of cyclophosphamide and its metabolite carboxyethylphosphoramide mustard (CEPM) was developed using online sample preparation and separation with tandem mass spectrometric detection. Diluted plasma was injected onto an extraction column (Cyclone MAX 0.5 mm × 50 mm, >30 μm), the sample matrix was washed with an aqueous solution, and retained analytes were transferred to an analytical column (Gemini 3 μm C18 110A, 100 mm × 2.0 mm) using a gradient mobile phase prior to detection by MS/MS. Analytes were detected in an API-3000 LC-MS/MS system using positive multiple-reaction monitoring mode (m/z 261/140 and 293/221 for CTX and CEPM, respectively). Online extraction recoveries were 76% and 72% for cyclophosphamide and CEPM. Within-day and between-day variabilities were <3.0%, and accuracies were between ?6.9% and 5.2%. This method has been used to measure plasma cyclophosphamide and CEPM concentrations in an ongoing Phase II study in children with newly diagnosed medulloblastoma.  相似文献   

15.
建立分散固相萃取剂-液相色谱串联质谱法(HPLC-MS/MS)同时检测鸡肉及鸡蛋中氟苯尼考和氟苯尼考胺的方法.样品用乙腈提取,C18分散固相萃取填料净化,乙腈饱和的正己烷脱脂,电喷雾离子源正负模式切换,HPLC-MS/MS多反应监测(MRM),同位素内标法定量.氟苯尼考和氟苯尼考胺线性范围分别为0.1 ng/mL~2....  相似文献   

16.
Dronedarone, a noniodinated benzofuran derivative of amiodarone, is believed to have a better side effect profile, and is currently undergoing phase III clinical trials. A novel method was developed for the determination of dronedarone and its principal metabolite debutyldronedarone in both plasma and myocardial tissue by high-performance liquid chromatography (HPLC) coupled with UV-detection. The assay was also validated for determination of amiodarone and desethylamiodarone. Samples were obtained from healthy humans (plasma) and goats (plasma and myocardium). Sample preparation included deproteinization with acetonitrile and extraction with a mixture of heptane and dichloromethane (50/50, v/v). Chromatographic separation was performed on a Pathfinder PS polymeric C18 column (50 mm × 4.6 mm, 2.5 μm) with a mobile phase of acetonitrile, isopropanol, water and ammonia (80/10/10/0.025, v/v/v/v) at a flow-rate of 1 ml/min. Calibration curves of all analytes were linear in the range of 0.01–5 μg/ml for plasma samples, with a lower limit of quantification (LLOQ) of 0.04 μg/ml. For myocardial tissue samples, linear curves of all analytes were observed in the range of 0.02–500 μg/g, with a LLOQ of 0.08 μg/g. Within- and between-day precision was <18%, and within- and between-day accuracy ranged from 97.5 to 109.7%, with a recovery of 67.6–79.9%. The present method enables sensitive and specific detection of dronedarone, amiodarone and principal metabolites in plasma as well as myocardial tissue.  相似文献   

17.
A simple, sensitive and reproducible gas chromatographic–mass spectrometric method was developed for monitoring ractopamine (RAC) and clenbuterol (CLB) in feeds. Feed samples were extracted with 0.1 M perchloric acid, centrifuged, neutralized, followed by liquid–liquid extraction with ethyl acetate-isopropanol (9:1, v/v). The concentrated extracts were dissolved in 0.02 M NH4Ac (pH 5.2), and applied to a solid phase extraction SCX cartridge for cleanup. The drugs were eluted with 3% (v/v) ammonia hydroxide in methanol, and the eluate was evaporated to dryness. The residue was derivatized with N,O-bis (trimethylsilyl) trifluoroacetamide at 80 °C for 1 h, and cooled, then analyzed by gas chromatography–mass spectrometry. The selected ions monitoring mode was performed at m/z 179, 250, 267 and 502 for RAC, and m/z 86, 243, 262 and 277 for CLB. Recoveries of RAC and CLB from concentrated feeds and premix fortified at 10, 100 and 5000 μg/kg were between 64.6 and 84.2%, with relative standard deviations of less than 15%. The limits of detection were about 4 μg/kg for RAC and 2 μg/kg for CLB.  相似文献   

18.
A simple and sensitive high-performance liquid chromatography with ultraviolet detection (HPLC-UV) method has been developed and validated for simultaneous quantification of five local anesthetics in human plasma: procaine, lidocaine, ropivacaine, tetracaine and bupivacaine. In an ice-water bath, 500 μL plasma sample, containing 100 μg/mL neostigmine methylsulfate as anticholinesterase, was spiked with carbamazepine as internal standard and alkalized by sodium hydroxide. Liquid–liquid extraction with ethyl ether was used for plasma sample preparation. The chromatographic separation was achieved on a Kromosil ODS C18 column with a mobile phase consisting of 30 mM potassium dihydrogen phosphate buffer (0.16% triethylamine, pH adjusted to 4.9 with phosphoric acid) and acetonitrile (63/37, v/v). The detection was performed simultaneously at wavelengths of 210 and 290 nm. The chromatographic analysis time was 13 min per sample. The calibration curves of all five analytes were linear between 0.05 and 5.0 μg/mL (r2  0.998). Precision ranged from 1.4% to 7.9% and accuracy was between 91.7% and 106.5%. The validated method is applicable for simultaneous determination of procaine, lidocaine, ropivacaine, tetracaine and bupivacaine for therapeutic drug monitoring and pharmacokinetic study.  相似文献   

19.
A rapid liquid chromatographic–tandem mass spectrometric (LC–MS/MS) multi-residue method for the simultaneous quantitation and identification of sixteen synthetic growth promoters and bisphenol A in bovine milk has been developed and validated. Sample preparation was straightforward, efficient and economically advantageous. Milk was extracted with acetonitrile followed by phase separation with NaCl. After centrifugation, the extract was purified by dispersive solid-phase extraction with C18 sorbent material. The compounds were analysed by reversed-phase LC–MS/MS using both positive and negative ionization and operated in multiple reaction monitoring (MRM) mode, acquiring two diagnostic product ions from each of the chosen precursor ions for unambiguous confirmation. Total chromatographic run time was less than 10 min for each sample. The method was validated at a level of 1 μg L?1. A wide variety of deuterated internal standards were used to improve method performance. The accuracy and precision of the method were satisfactory for all analytes. The confirmative quantitative liquid chromatographic tandem mass spectrometric (LC–MS/MS) method was validated according to Commission Decision 2002/657/EC. The decision limit (CCα) and the detection capability (CCβ) were found to be below the chosen validation level of 1 μg L?1 for all compounds.  相似文献   

20.
A rapid and sensitive LC–MS/MS method for the determination of vardenafil and its major metabolite, N-desethylvardenafil, in human plasma using sildenafil as an internal standard was developed and validated. The analytes were extracted from 0.25-mL aliquots of human plasma by liquid–liquid extraction, using 1 mL of ethyl acetate. Chromatographic separation was carried on a Luna C18 column (50 mm × 2.0 mm, 3 μm) at 40 °C, with an isocratic mobile phase consisting of 10 mM ammonium acetate (pH 5.0) and acetonitrile (10:90, v/v), a flow rate of 0.2 mL/min, and a total run time of 2 min. Detection and quantification were performed using a mass spectrometer in the selected reaction-monitoring mode with positive electrospray ionization at m/z 489.1  151.2 for vardenafil, m/z 460.9  151.2 for N-desethylvardenafil, and m/z 475.3  100.1 for the internal standard (IS), respectively. This assay was linear over a concentration range of 0.5–200 ng/mL with a lower limit of quantification of 0.5 ng/mL for both vardenafil and N-desethylvardenafil. The coefficient of variation for the assay precision was <13.6%, and the accuracy was >93.1%. This method was successfully applied to a pharmacokinetic study after oral administration of vardenafil 20 mg tablet in Korean healthy male volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号