首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high throughput and specific method using ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) was developed for the simultaneous determination of diltiazem and its two metabolite (N-desmethyldiltiazem and O-desacetyldiltiazem) in human plasma. A one-step liquid–liquid extraction (LLE) with methyl-t-butyl ether (MTBE) involved for the extraction of diltiazem (DLTZ), metabolites (DMeD and DAcD) and internal standard. Analytes were chromatographed on a ACQUITY UPLC? BEH C18 column (100 mm × 2.1 mm, i.d., 1.7 μm) with isocratic elution at a flow rate of 0.2 mL/min using 10 mM ammonium acetate buffer–acetonitrile (25:75, v/v). The Quattro Premier XE LC–MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. Using 300 μL plasma, the method was validated over the concentration range 0.48–639.9 ng/mL for DLTZ and 0.24–320.1 for DMeD and 0.24–320.7 ng/mL for DAcD, with a lower limit of quantification of 0.48 ng/mL for DLTZ and 0.24 ng/mL for metabolites. The intra- and inter-day precision and accuracy were within 10.0%. The recovery was 77.4%, 76.0%, 74.5% and 74.1% for DLTZ, DMeD, DAcD and Ziprasidone, respectively. Total run time was 2.0 min only.  相似文献   

2.
Pyrrole (Py)–imidazole (Im) polyamides synthesized by combining N-methylpyrrole and N-methylimidazole amino acids have been identified as novel candidates for gene therapy. In this study, a sensitive method using liquid chromatography–tandem mass spectrometry (LC–MS/MS) with an electrospray ionization (ESI) source was developed and validated for the determination and quantification of Py–Im polyamide in rat plasma. Py–Im polyamide was extracted from rat plasma by solid-phase extraction (SPE) using a Waters Oasis® HLB cartridge. Separation was achieved on an ACQUITY UPLC HSS T3 (1.8 μm, 2.1 × 50 mm) column by gradient elution using acetonitrile:distilled water:acetic acid (5:95:0.1, v/v/v) and acetonitrile:distilled water:acetic acid (95:5:0.1, v/v/v). The method was validated over the range of 10–1000 ng/mL and the lower limit of quantification (LLOQ) was 10 ng/mL. This method was successfully applied to the investigation of the pharmacokinetics of Py–Im polyamide after intravenous administration.  相似文献   

3.
A rapid and sensitive bioassay based on liquid chromatography–tandem mass spectrometry (LC–MS/MS) for the simultaneous determination of four isomeric escin saponins (escin Ia, escin Ib, isoescin Ia and isoescin Ib) in human plasma has been developed and validated. Sample preparation of plasma after addition of telmisartan as internal standard (I.S.) involved solid-phase extraction (SPE) on C18 cartridges. Separation was based on reversed phase chromatography using gradient elution with methanol–acetonitrile (50:50, v/v) and 10 mM ammonium acetate solution (pH 6.8). MS/MS detection in the positive ion mode used multiple reaction monitoring of the transition at m/z 1113.8  807.6. Stability issues with the four saponins required the addition of formic acid to plasma samples prior to storage at ?80 °C and analysis within 30 days. The method was linear at concentrations up to 10 ng/mL with correlation coefficients > 0.996 for all analytes. The lower limit of quantitation (LLOQ) for all four saponins was 33 pg/mL. Intra- and inter-day precisions (as relative standard deviation) were all <15% and accuracies (as relative error) in the range ?5.3% to 6.1%. The method was successfully applied to a pharmacokinetic study of escins in healthy volunteers after oral administration of sodium aescinate tablets containing 60 mg escin saponins.  相似文献   

4.
A new simple, rapid, sensitive and accurate quantitative detection method using liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) for the measurement of formononetin (FMN) and daidzein (DZN) levels in rat plasma is described. Analytes were separated on a Supelco Discovery C18 (4.6 × 50 mm, 5.0 μm) column with acetonitrile: methanol (50:50, v/v) and 0.1% acetic acid in the ratio of 90:10 (v/v) as a mobile phase. The method was proved to be accurate and precise at linearity range of 5–100 ng/mL with a correlation coefficient (r) of ≥0.996. The intra- and inter-day assay precision ranged from 1.66–6.82% and 1.87–6.75%, respectively; and intra- and inter-day assay accuracy was between 89.98–107.56% and 90.54–105.63%, respectively for both the analytes. The lowest quantitation limit for FMN and DZN was 5.0 ng/mL in 0.1 mL of rat plasma. Practical utility of this new LC–MS/MS method was demonstrated in a pharmacokinetic study in rats following intravenous administration of FMN.  相似文献   

5.
A rapid, selective and sensitive high performance liquid chromatography–tandem mass spectrometry method (LC–MS/MS) was developed and validated for the determination and pharmacokinetic investigation of cefuroxime in human plasma. Cefuroxime and the internal standard (IS), cefoxitin, were extracted from plasma samples using solid phase extraction with Oasis HLB cartridges. Chromatographic separation was performed on a LiChrospher® 60 RP Select B column (125 mm × 4 mm i.d., 5 μm particle size) using acetonitrile:5 ± 0.2 mM ammonium acetate solution:glacial acetic acid (70:30:0.020, v/v/v) as the mobile phase at a flow rate of 0.8 mL/min. Detection of cefuroxime and cefoxitin was achieved by tandem mass spectrometry with an electrospray ionization (ESI) interface in negative ion mode. The calibration curves were linear over the range of 81.0–15976.2 ng/mL with the lower limit of quantitation validated at 81.0 ng/mL. The intra- and inter-day precisions were within 7.6%, while the accuracy was within ±6.3% of nominal values. No matrix effect was observed in this method. The validated LC–MS/MS method was successfully applied for the evaluation of pharmacokinetic and bioequivalence parameters of cefuroxime after an oral administration of 500 mg cefuroxime tablet to 36 healthy male volunteers.  相似文献   

6.
Puerarin is a major active ingredient of Pueraria Radix. Puerarin may exert its medicinal functions in part via its metabolites. In this study, we identified these metabolites to better understand and elucidate puerarin's metabolic pathway. Puerarin was intravenously administered to rats and then metabolites in plasma samples were identified by rapid resolution liquid chromatography electrospray ionization-collision induced dissociation tandem mass spectrometry (RRLC-ESI-CID–MS/MS). Chromatography was conducted on a Zorbax SB C18 column (2.1 × 100 mm, 1.8 μm) at 30 °C, with a gradient mobile phase consisting of 0.05% formic acid and acetonitrile, a flow rate of 0.2 mL min?1, and a total run time of 14 min. MS/MS acquisition parameters were as follows: positive ionization mode, dry gas: nitrogen, 10 L min?1, dry temperature: 350 °C, nebulizer: 40 psi, capillary: ?3500 V, scan range: 250–800. The autoMS, manual, or multiple reaction monitoring mode was selected as required. Two glucuronidated metabolites of puerarin (M1 and M2) were detected. M1 and M2 are presumed to be puerarin-7-O-glucuronide and puerarin-4′-O-glucuronide, respectively, and M2 likely is suspected to be the major metabolite because it represented the predominate peak. Kinetic studies of metabolites demonstrated that M1 and M2 were detected in rat plasma at 5 min after intravenous administration of puerarin, the levels of M1 and M2 then reached their peaks at 10–15 and 15–30 min, respectively. The metabolic profiles were similar in rat liver and intestine investigated by in situ liver and intestine perfusion, indicating that no metabolic regioselectivity of puerarin occurs in the two organs.  相似文献   

7.
A reverse-phase liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) method was developed and validated for determination of aminoflavone (AF) in human plasma. Sample preparation involved a liquid–liquid extraction by the addition of 0.25 mL of plasma with 1.0 mL ethyl acetate containing 50 ng/mL of the internal standard zileuton. The analytes were separated on a Waters X-Terra? MS C18 column using a mobile phase consisting of methanol/water containing 0.45% formic acid (70:30, v/v) and isocratic flow at 0.2 mL/min for 6 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the AF concentration range of 5–2000 ng/mL in human plasma. The lower limit of quantitation (LLOQ) was 5 ng/mL for AF in human plasma. The accuracy and within- and between-day precisions were within the generally accepted criteria for bioanalytical method (<15%). This method was successfully applied to characterize AF plasma concentration-time profile in the cancer patients in a phase I trial.  相似文献   

8.
A selective and sensitive liquid chromatography (LC)–atmospheric pressure chemical ionisation (APCI)–mass spectroscopic (MS) assay of canrenone has been developed and validated employing Dried Blood Spots (DBS) as the sample collection medium. DBS samples were prepared by applying 30 μl of spiked whole blood onto Guthrie cards. A 6 mm disc was punched from the each DBS and extracted with 2 ml of methanolic solution of 17α-methyltestosterone (Internal Standard). The methanolic extract was evaporated to dryness and reconstituted in acetonitrile:water (1:9, v/v). The reconstituted solution was further subjected to solid phase extraction using HLB cartridges. Chromatographic separation was achieved using Waters Sunfire C18 reversed-phase column using isocratic elution, followed by a high organic wash to clear late eluting/highly retained components. The mobile phase consisted of methanol:water (60:40, v/v) pumped at a flow rate of 0.3 ml/min. LC–APCI–MS detection was performed in the selected-ion monitoring (SIM) mode using target ions at m/z 341.1 and 303.3 for canrenone and internal standard respectively. The selectivity of the method was established by analysing DBS samples from 6 different sources (individuals). The calibration curve for canrenone was found to be linear over 25–1000 ng/ml (r > 0.994). Accuracy (% RE) and precision (% CV) values for within and between day were <20% at the lower limit of quantification (LLQC) and <15% at all other concentrations tested. The LLOQ of the method was validated at 25 ng/ml. Clinical validation of the method was achieved by employing the validated method for analysis of 160 DBS samples from 37 neonatal and paediatric patients.  相似文献   

9.
For the rapid, selective and sensitive analysis of metoclopramide in human plasma, hydrophilic interaction chromatography with electrospray ionization tandem mass spectrometric (HILIC/MS/MS) method was developed. This method involved liquid–liquid extraction with dichloromethane followed by separation on an Atlantis HILIC silica column using the mobile phase of acetonitrile–ammonium formate (100 mM, pH 6.5) (85:15, v/v). Analytes were quantified using electrospray ionization mass spectrometry in the selected reaction monitoring mode. The standard curve was linear (r2 = 0.998) over the concentration range of 2.00–150 ng/mL using 50 μL of plasma sample. The coefficient of variation and relative error for intra- and inter-assay at four QC levels were 1.8–7.7% and ?7.5 to 3.6%, respectively. The matrix effect for metoclopramide and levosulpiride (internal standard) was practically absent. The present method was successfully applied to the pharmacokinetic study of metoclopramide after oral dose of metoclopramide hydrochloride (10 mg) to male healthy volunteers.  相似文献   

10.
This paper describes a rapid and sensitive method for the quantitation of 20(S)-protopanaxadiol (PPD) in human plasma based on high-performance liquid chromatography–tandem mass spectrometry (LC–MS/MS). The analyte and internal standard (I.S.), ginsenoside Rh2, were extracted from plasma by liquid–liquid extraction and separated on a Zorbax extend C18 analytical column using methanol–acetonitrile-10 mM ammonium acetate (47.5:47.5:5, v/v/v) as mobile phase. Detection was by tandem mass spectrometry using electrospray ionization in the positive ion mode and multiple reaction monitoring (MRM). The assay was linear over the concentration range 0.1–100.0 ng/ml with a limit of detection of 0.05 ng/ml. The method was successfully applied to a clinical pharmacokinetic study in healthy volunteers after a single oral administration of a PPD 25 mg capsule.  相似文献   

11.
A highly sensitive and selective LC–MS/MS method was developed and validated for the determination of dauricine in human plasma, using protopine as internal standard (IS). The analyte and IS were extracted by liquid–liquid extraction and analyzed by LC–MS/MS. Chromatographic separation was performed on Agilent TC-C18 column with a mobile phase of methanol–water–glacial acetic acid (60:40:0.8, v/v/v) at a flow rate of 0.7 mL/min. Detection was performed on a triple quadrupole tandem mass spectrum by multiple reaction monitoring (MRM) mode using the electrospray ionization technique in positive mode. The method was linear over the concentration range of 1–200 ng/mL. The lower limit of quantification (LLOQ) was 1 ng/mL in human plasma with acceptable precision and accuracy. The intra- and inter-day precision was less than 5.9% determined from quality control (QC) samples at concentrations of 2.0, 20.0 and 160 ng/mL, and the accuracy was within ±9.9%. This method was successfully applied for the evaluation of pharmacokinetics of dauricine after oral doses of 100, 300 and 600 mg phenolic alkaloids of menispermum dauricum tablet (PAMDT) to 12 Chinese healthy volunteers.  相似文献   

12.
Dronedarone, a noniodinated benzofuran derivative of amiodarone, is believed to have a better side effect profile, and is currently undergoing phase III clinical trials. A novel method was developed for the determination of dronedarone and its principal metabolite debutyldronedarone in both plasma and myocardial tissue by high-performance liquid chromatography (HPLC) coupled with UV-detection. The assay was also validated for determination of amiodarone and desethylamiodarone. Samples were obtained from healthy humans (plasma) and goats (plasma and myocardium). Sample preparation included deproteinization with acetonitrile and extraction with a mixture of heptane and dichloromethane (50/50, v/v). Chromatographic separation was performed on a Pathfinder PS polymeric C18 column (50 mm × 4.6 mm, 2.5 μm) with a mobile phase of acetonitrile, isopropanol, water and ammonia (80/10/10/0.025, v/v/v/v) at a flow-rate of 1 ml/min. Calibration curves of all analytes were linear in the range of 0.01–5 μg/ml for plasma samples, with a lower limit of quantification (LLOQ) of 0.04 μg/ml. For myocardial tissue samples, linear curves of all analytes were observed in the range of 0.02–500 μg/g, with a LLOQ of 0.08 μg/g. Within- and between-day precision was <18%, and within- and between-day accuracy ranged from 97.5 to 109.7%, with a recovery of 67.6–79.9%. The present method enables sensitive and specific detection of dronedarone, amiodarone and principal metabolites in plasma as well as myocardial tissue.  相似文献   

13.
C. Gómez  O.J. Pozo  L. Garrostas  J. Segura  R. Ventura 《Steroids》2013,78(12-13):1245-1253
Metandienone is one of the most frequently detected anabolic androgenic steroids in sports drug testing. Metandienone misuse is commonly detected by monitoring different metabolites excreted free or conjugated with glucuronic acid using gas chromatography mass spectrometry (GC–MS) and liquid chromatography tandem mass spectrometry (LC–MS/MS) after hydrolysis with β-glucuronidase and liquid–liquid extraction. It is known that several metabolites are the result of the formation of sulphate conjugates in C17, which are converted to their 17-epimers in urine. Therefore, sulphation is an important phase II metabolic pathway of metandienone that has not been comprehensively studied. The aim of this work was to evaluate the sulphate fraction of metandienone metabolism by LC–MS/MS. Seven sulphate metabolites were detected after the analysis of excretion study samples by applying different neutral loss scan, precursor ion scan and SRM methods. One of the metabolites (M1) was identified and characterised by GC–MS/MS and LC–MS/MS as 18-nor-17β-hydroxymethyl-17α-methylandrost-1,4,13-triene-3-one sulphate. M1 could be detected up to 26 days after the administration of a single dose of metandienone (5 mg), thus improving the period in which the misuse can be reported with respect to the last long-term metandienone metabolite described (18-nor-17β-hydroxymethyl-17α-methylandrost-1,4,13-triene-3-one excreted in the glucuronide fraction).  相似文献   

14.
A sensitive and specific method using ultra performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) was developed for the determination of levetiracetam (LEV) in plasma of neonates. A plasma aliquot of 50 μl was deproteinized by addition of 500 μl methanol which contained 5 μg/ml UCB 17025 as an internal standard. After centrifugation, 50 μl of supernatant was diluted with 1000 μl of 0.1% formic acid–10 mM ammonium formate in water (pH 3.5) (mobile phase solution A) and 2 μl was injected onto the UPLC-system. Compounds were separated on a Acquity UPLC BEH C18 2.1 mm × 100 mm column using gradient elution with mobile phase solution A and 0.1% formic acid in methanol (mobile phase solution B) with a flow rate of 0.4 ml/min and a total runtime of 4.0 min. LEV and the internal standard were detected using positive ion electrospray ionization followed by tandem mass spectrometry (ESI-MS/MS). The assay allowed quantification of LEV plasma concentrations in the range from 0.5 μg/ml to 150 μg/ml. Inter-assay inaccuracy was within ±2.7% and inter-assay precision was less than 4.5%. Matrix effects were minor: the recovery of LEV was between 97.7% and 100%. The developed method required minimal sample preparation and less plasma sample volume compared to earlier published LC–MS/MS methods. The method was successfully applied in a clinical pharmacokinetic study in which neonates received intravenous administrations of LEV for the treatment of neonatal seizures.  相似文献   

15.
A simple sensitive and robust method for simultaneous determination of citalopram and desmethylcitalopram was developed using liquid chromatography tandem mass spectrometry (LC–MS/MS). A 200 μL aliquot of plasma sample was employed and deproteinized with methanol and desipramine was used as the internal standard. After vortex mixing and centrifugation, the supernatant was diluted with water (1:1, v/v) and then directly injected to analysis. Analytes were separated by a Zorbax XDB C18 column with the mobile phase composed of acetonitrile and water (30:70, v/v) with 0.25% formic acid and monitored in MRM mode using a positive electrospray source with tandem mass spectrometry detection. The total run time was 3.5 min. The dynamic range was 0.2–100 ng/mL for citalopram and 0.25–50 ng/mL for desmethylcitalopram, respectively. Compared to the best existing literatures for plasma samples, the same LOQ for CIT (0.5 ng/mL) and lower LOQ for DCIT (0.25 vs 5 ng/mL) were reached, and less sample preparation steps and runtime (3.5 vs 10 min) were taken for our method. Accuracy and precision was lower than 8% and lower than 11.5% for either target. Validation results and its application to the analysis of plasma samples after oral administration of citalopram in healthy Chinese volunteers demonstrated the method was applicable to pharmacokinetic studies.  相似文献   

16.
A high-performance liquid chromatographic method with fluorescence detection for the determination of itopride in human plasma is reported. The sample preparation was based on liquid–liquid extraction of itopride from plasma with t-butylmethylether and dichloromethane (70:30, v/v) mixture followed by a back extraction of the analyte to the phosphate buffer (pH 3.2). Liquid chromatography was performed on an octadecylsilica column (55 mm × 4 mm, 3 μm particles), the mobile phase consisted of acetonitrile–triethylamine–15 mM dihydrogenpotassium phosphate (14.5:0.5:85, v/v/v), pH of the mobile phase was adjusted to 4.8. The run time was 3 min. The fluorimetric detector was operated at 250/342 nm (excitation/emission wavelength). Naratriptan was used as the internal standard. The limit of quantitation was 9.5 ng/ml using 0.5 ml of plasma. The method precision and inaccuracy were less than 8%. The assay was applied to the analysis of samples from a bioequivalence study.  相似文献   

17.
With the expanded use of the combination of artesunate (AS) and amodiaquine (AQ) for the treatment of falciparum malaria and the abundance of products on the market, comes the need for rapid and reliable bioanalytical methods for the determination of the parent compounds and their metabolites. While the existing methods were developed for the determination of either AS or AQ in biological fluids, the current validated method allows simultaneous extraction and determination of AS and AQ in human plasma. Extraction is carried out on Supelclean LC-18 extraction cartridges where AS, its metabolite dihydroartemisinin (DHA) and the internal standard artemisinin (QHS) are separated from AQ, its metabolite desethylamodiaquine (DeAQ) and the internal standard, an isobutyl analogue of desethylamodiaquine (IB-DeAQ). AS, DHA and QHS are then analysed using Hypersil C4 column with acetonitrile–acetic acid (0.05 M adjusted to pH 5.2 with 1.00 M NaOH) (42:58, v/v) as mobile phase at flow rate 1.50 ml/min. The analytes are detected with an electrochemical detector operating in the reductive mode. Chromatography of AQ, DeAQ and IB-DeAQ is carried out on an Inertsil C4 column with acetonitrile–KH2PO4 (pH 4.0, 0.05 M) (11:89, v/v) as mobile phase at flow rate 1.00 ml/min. The analytes are detected by an electrochemical detector operating in the oxidative mode. The recoveries of AS, DHA, AQ and DeAQ vary between 79.1% and 104.0% over the concentration range of 50–1400 ng/ml plasma. The accuracies of the determination of all the analytes are 96.8–103.9%, while the variation for within-day and day-to-day analysis are <15%. The lower limit of quantification for all the analytes is 20 ng/ml and limit of detection is 8 ng/ml. The method is sensitive, selective, accurate, reproducible and suited particularly for pharmacokinetic study of AS–AQ drug combination and can also be used to compare the bioavailability of different formulations, including a fixed-dose AS–AQ co-formulation.  相似文献   

18.
BackgroundSelenium is important for human health and involved in various metabolic processes. Deficiency of selenium associates with increased risk for cancer and cardiovascular diseases. There has been an increase use of selenium supplements for the treatment of autoimmune thyroid conditions. However, the potential biological effects of selenium overload arouse the public concern. The aim of this study was to investigate the associations of plasma selenium concentrations of adults with metabolic syndrome (MS) in Chinese population.MethodsA matched case-control study including 204 metabolic syndrome patients and 204 healthy controls was conducted in 2012. The MS cases were defined according to the criteria of Chinese Diabetes Society (CDS). Healthy controls without abnormality of metabolic components were matched with cases in age, gender and region. Plasma concentrations of selenium were determined by graphite furnace atomic absorption spectrometry (GFAAS). Fasting plasma glucose (FPG), total cholesterol (TC), triglycerides (TG), high density lipoprotein cholesterol (HDL), and low density lipoprotein cholesterol (LDL) were detected by automatic biochemical analyzer.ResultsThe median levels of plasma selenium in MS group were 146.3 (107.3–199.4) μg/L, which were significantly higher than that in the control group (127.4: 95.7–176.0) μg/L; Plasma levels of selenium were related to the risk of MS in dose-response manner. Risk of MS was significantly higher in subjects with plasma selenium in the highest tertile (T3: ≥176.0 μg/L) compared to those in the lowest tertile (T1: <95.7 μg/L) [odds ratio (OR) = 2.416 (95% CI: 1.289–4.526)]. The plasma levels of selenium were positively correlated with fasting plasma glucose (FPG) (rs = 0.268, P < 0.001). Plasma selenium at the median (T2: 95.7–176.0 μg/L) or upper tertile (T3: ≥176.0 μg/L) was associated with increased risk of elevated FPG (defined by FPG  6.1 mmol/L) as compared with the lowest tertile (T1: ≤95.7 μg/L) [T2 vs. T1, OR = 3.487 (1.738–6.996); T3 vs. T1, OR = 6.245 (3.005–12.981)].ConclusionsHigher levels of plasma selenium might increase the risk of metabolic syndrome and elevated fasting plasma glucose. Selenium supplements should be used with prudence for CVD and cancer prevention.  相似文献   

19.
A selective, sensitive and high throughput liquid chromatography–tandem mass spectrometry (LC–ESI-MS/MS) method has been developed and validated for the chromatographic separation and quantitation of (E)-entacapone and (Z)-entacapone in human plasma. Sample clean-up involved liquid–liquid extraction (LLE) of both the isomers and carbamazepine used as internal standard from 500 μL of human plasma. Both the analytes were chromatographically separated with a resolution factor of 3.0 on a Gemini C18 (50 mm × 4.6 mm, 5 μm particle size) analytical column using 1% formic acid and methanol (50:50, v/v) as the mobile phase. The selectivity factor (α) of the column for the separation was 2.0, based on the capacity factors of 2.6 and 1.3 for (E)- and (Z)-isomers respectively. The parent  product ion transitions for both the isomers (m/z 306.1  233.0) and IS (m/z 237.3  194.2) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) and positive ion mode. The method was validated over the concentration range of 24.3–6076 ng/mL and 23.8–5960 ng/mL for (E)-entacapone and (Z)-entacapone respectively. Matrix effect was assessed by post-column analyte infusion experiment and the process/extraction efficiency found was 94.3% and 89.3% for (E)- and (Z)-isomers respectively. The method was successfully applied to a pivotal bioequivalence study in 36 healthy human subjects after oral administration of 200 mg (E)-entacapone tablet formulation under fasting conditions.  相似文献   

20.
A rapid, sensitive and specific high performance liquid chromatography–tandem mass spectrometric (HPLC–MS/MS) method has been developed for quantification of mitoxantrone in rat plasma. The analyte and palmatine (internal standard) were extracted from plasma samples with diethyl ether–dichloromethane (3:2, v/v) and separated on a C18 column. The chromatographic separation was achieved within 2.5 min using methanol–10 mM ammonium acetate containing 0.1% acetic acid as the mobile phase at a flow rate of 0.2 mL/min. The method was linear over the range of 0.5–500 ng/mL. The lower limit of quantification (LLOQ) was 0.5 ng/mL. Finally, the method was successfully applied to a pharmacokinetic study of mitoxantrone in rats following intravenous administration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号