首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, rapid and accurate liquid chromatography–tandem mass spectrometry (LC–MS/MS) method has been developed and validated for the determination of mildronate in human plasma. Following a simple protein precipitation with methanol, the analyte was separated on a C18 column by isocratic elution with methanol and 10 mM ammonium acetate (55:45; v/v), and then analyzed by mass spectrometry in the positive ion MRM mode. Good linearity was achieved over a wide range of 0.01–20 μg/mL. The intra- and inter-batch precisions (as RSD, %) were less than 7.1%. The average extraction recovery was 87.5%. The method described above has been used, for the first time, to reveal the pharmacokinetics of mildronate injection in healthy subjects. After single intravenously administration of 250, 500 and 1000 mg mildronate, the elimination half-life (t1/2) were (5.56 ± 1.55), (6.46 ± 1.07) and (6.55 ± 1.17) h, respectively. The Student–Newman–Keuls test results showed that peak plasma concentration (Cmax) and the area under the plasma concentration versus time curve from time 0 to 24 h (AUC0–24) were both linearly related to dose. The pharmacokinetics of mildronate fitted the linear dynamic feature over the dose range studied. The essential pharmacokinetic parameters of multidoses administration intravenously (500 mg, b.i.d) were as follows: t1/2 was (15.34 ± 3.14) h; Cmax was (25.50 ± 3.63) μg/mL; AUC0–24 was (58.56 ± 5.57) mg h/L. The t1/2 and AUC of multidoses administration intravenously were different from those of single-dose administration significantly. These findings suggested that accumulation of mildronate in plasma occurred.  相似文献   

2.
A sensitive and specific electrospray ionization liquid chromatography–tandem mass spectrometry method was developed to detect diosgenin in the plasma of normal and hyperlipidemic rats. Diosgenin was extracted with n-hexane–ethyl acetate (9:1, v/v) using sarsasapogenin as an internal standard. With multiple reaction monitoring modes, linear calibration curves were obtained in the range 10–1500 ng/mL (r  0.9979) and the limit of quantification was 10 ng/mL. Intra- and inter-assay variabilities were within 7.74%, and accuracies were between ?5.33% and 1.50%. The assay was successfully applied to study pharmacokinetics in rats after oral administration of diosgenin. Significantly different pharmacokinetics between normal and hyperlipidemic rats were observed, which would be beneficial for the clinical use of diosgenin.  相似文献   

3.
A rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the determination of picamilon concentration in human plasma. Picamilon was extracted from human plasma by protein precipitation. High performance liquid chromatography separation was performed on a Venusil ASB C18 column with a mobile phase consisting of methanol ?10 mM ammonium acetate–formic acid (55:45:01, v/v/v) at a flow rate of 0.65 ml/min. Acquisition of mass spectrometric data was performed in selected reaction monitoring mode, using the transitions of m/z 209.0  m/z (78.0 + 106.0) for picamilon and m/z 152.0  m/z (93.0 + 110.0) for paracetamol (internal standard). The method was linear in the concentration range of 1.00–5000 ng/ml for the analyte. The lower limit of quantification was 1.00 ng/ml. The intra- and inter-assay precision were below 13.5%, and the accuracy was between 99.6% and 101.6%. The method was successfully applied to characterize the pharmacokinetic profiles of picamilon in healthy volunteers. This validated LC–MS/MS method was selective and rapid, and is suitable for the pharmacokinetic study of picamilon in humans.  相似文献   

4.
A sensitive and selective liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed to determine the concentration of eptifibatide in human plasma. Following protein precipitation, the analyte was separated on a reversed-phase C18 column. Acetonitrile:5 mM ammonium acetate:acetic acid (30:70:0.1, v/v/v) was used at a flow-rate of 0.5 mL/min with the isocratic mobile phase. An API 4000 tandem mass spectrometer equipped with a Turbo IonSpray ionization source was used as the detector and was operated in the positive ion mode. “Truncated” multiple reaction monitoring using the transition of m/z 832.6  m/z 832.6 and m/z 931.3  m/z 931.3 was performed to quantify eptifibatide and the internal standard (EPM-05), respectively. The method had a lower limit of quantification of 4.61 ng/mL for eptifibatide. The calibration curve was demonstrated to be linear over the concentration range of 4.61 ? 2770 ng/mL. The intra- and inter-day precisions were less than 10.5% for each QC level, and the inter-day relative errors were 2.0%, 5.6%, and 2.8% for 9.22, 184, and 2490 ng/mL, respectively. The validated method was successfully applied to the quantification of eptifibatide concentration in human plasma after intravenous (i.v.) administration of a 270-μg/kg bolus of eptifibatide and i.v. administration of eptifibatide at a constant rate of infusion of 2 μg/(kg min) for 18 h in order to evaluate the pharmacokinetics.  相似文献   

5.
《Process Biochemistry》2007,42(11):1537-1545
Crude glycerol is the primary by-product in the biodiesel industry, which is too costly to be purified into to higher quality products used in the health and cosmetics industries. This work investigated the potential of using the crude glycerol to produce docosahexaenoic acid (DHA, 22:6 n-3) through fermentation of the microalga Schizochytrium limacinum. The results showed that crude glycerol supported alga growth and DHA production, with 75–100 g/L concentration being the optimal range. Among other medium and environmental factors influencing DHA production, temperature, trace metal (PI) solution concentration, ammonium acetate, and NH4Cl had significant effects (P < 0.1). Their optimal values were determined 30 mL/L of PI, 0.04 g/L of NH4Cl, 1.0 g/L of ammonium acetate, and 19.2 °C. A highest DHA yield of 4.91 g/L with 22.1 g/L cell dry weight was obtained. The results suggested that biodiesel-derived crude glycerol is a promising feedstock for production of DHA from heterotrophic algal culture.  相似文献   

6.
This paper describes a rapid and sensitive method for the quantitation of 20(S)-protopanaxadiol (PPD) in human plasma based on high-performance liquid chromatography–tandem mass spectrometry (LC–MS/MS). The analyte and internal standard (I.S.), ginsenoside Rh2, were extracted from plasma by liquid–liquid extraction and separated on a Zorbax extend C18 analytical column using methanol–acetonitrile-10 mM ammonium acetate (47.5:47.5:5, v/v/v) as mobile phase. Detection was by tandem mass spectrometry using electrospray ionization in the positive ion mode and multiple reaction monitoring (MRM). The assay was linear over the concentration range 0.1–100.0 ng/ml with a limit of detection of 0.05 ng/ml. The method was successfully applied to a clinical pharmacokinetic study in healthy volunteers after a single oral administration of a PPD 25 mg capsule.  相似文献   

7.
A rapid and sensitive LC–MS/MS method for the determination of vardenafil and its major metabolite, N-desethylvardenafil, in human plasma using sildenafil as an internal standard was developed and validated. The analytes were extracted from 0.25-mL aliquots of human plasma by liquid–liquid extraction, using 1 mL of ethyl acetate. Chromatographic separation was carried on a Luna C18 column (50 mm × 2.0 mm, 3 μm) at 40 °C, with an isocratic mobile phase consisting of 10 mM ammonium acetate (pH 5.0) and acetonitrile (10:90, v/v), a flow rate of 0.2 mL/min, and a total run time of 2 min. Detection and quantification were performed using a mass spectrometer in the selected reaction-monitoring mode with positive electrospray ionization at m/z 489.1  151.2 for vardenafil, m/z 460.9  151.2 for N-desethylvardenafil, and m/z 475.3  100.1 for the internal standard (IS), respectively. This assay was linear over a concentration range of 0.5–200 ng/mL with a lower limit of quantification of 0.5 ng/mL for both vardenafil and N-desethylvardenafil. The coefficient of variation for the assay precision was <13.6%, and the accuracy was >93.1%. This method was successfully applied to a pharmacokinetic study after oral administration of vardenafil 20 mg tablet in Korean healthy male volunteers.  相似文献   

8.
A novel precolumn derivatization reversed-phase high-performance liquid chromatography (RP-HPLC) method with UV–vis detection for the quantitative determination of total concentration of asiatic acid (AA) in beagle dog plasma is described. AA was extracted with n-hexane-dichloromethane-2-propanol (20:10:1, v/v/v) from plasma, which had been hydrolyzed by acid and derivatized with p-Toluidine. Chromatographic separation was achieved on a C18 column using gradient elution in a water–methanol system. Detection was set at UV wavelength of 248 nm. A calibration curve ranging from 0.01 to 1.5 μg/mL was shown to be linear, and the lower limit of quantification (LLOQ) was 0.01 μg/mL. The intra- and inter-day precisions which were determined by three different concentrations (0.05, 0.2 and 0.8 μg/mL) ranged from 4.4% to 13.1% and 4.6% to 14.2%, respectively. Mean extraction recoveries were no less than 65% for AA and ursolic acid (IS). Plasma samples containing asiatic acid were stable for 30 days at ?20 °C. The method was successfully applied to a pharmacokinetic study in beagle dogs after oral administration of Centella asiatica extract, and the main pharmacokinetic parameters obtained were: T1/2, 4.29 h; Tmax, 2.70 h; Cmax, 0.74 μg/mL; AUC0–t and AUC0–∞, 3.74 and 3.82 μg h/mL, respectively.  相似文献   

9.
A high throughput and specific method using ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) was developed for the simultaneous determination of diltiazem and its two metabolite (N-desmethyldiltiazem and O-desacetyldiltiazem) in human plasma. A one-step liquid–liquid extraction (LLE) with methyl-t-butyl ether (MTBE) involved for the extraction of diltiazem (DLTZ), metabolites (DMeD and DAcD) and internal standard. Analytes were chromatographed on a ACQUITY UPLC? BEH C18 column (100 mm × 2.1 mm, i.d., 1.7 μm) with isocratic elution at a flow rate of 0.2 mL/min using 10 mM ammonium acetate buffer–acetonitrile (25:75, v/v). The Quattro Premier XE LC–MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. Using 300 μL plasma, the method was validated over the concentration range 0.48–639.9 ng/mL for DLTZ and 0.24–320.1 for DMeD and 0.24–320.7 ng/mL for DAcD, with a lower limit of quantification of 0.48 ng/mL for DLTZ and 0.24 ng/mL for metabolites. The intra- and inter-day precision and accuracy were within 10.0%. The recovery was 77.4%, 76.0%, 74.5% and 74.1% for DLTZ, DMeD, DAcD and Ziprasidone, respectively. Total run time was 2.0 min only.  相似文献   

10.
A rapid, sensitive and specific high performance liquid chromatography–tandem mass spectrometric (HPLC–MS/MS) method has been developed for quantification of mitoxantrone in rat plasma. The analyte and palmatine (internal standard) were extracted from plasma samples with diethyl ether–dichloromethane (3:2, v/v) and separated on a C18 column. The chromatographic separation was achieved within 2.5 min using methanol–10 mM ammonium acetate containing 0.1% acetic acid as the mobile phase at a flow rate of 0.2 mL/min. The method was linear over the range of 0.5–500 ng/mL. The lower limit of quantification (LLOQ) was 0.5 ng/mL. Finally, the method was successfully applied to a pharmacokinetic study of mitoxantrone in rats following intravenous administration.  相似文献   

11.
The synthesis of the omega-3 long-chain polyunsaturated fatty acids (LCPUFA)  eicosapentaenoic acid (EPA; 20:5n− 3) and docosahexaenoic acid (DHA; 22:6n  3) from dietary α-linolenic acid (ALA; 18:3n  3) requires three desaturation and three elongation steps in vertebrates. The elongation of EPA to docosapentaenoic acid (DPA; 22:5n  3) can be catalysed by the elongase enzymes Elovl5 or Elovl2, but further elongation of DPA to 24:5n  3, the penultimate precursor of DHA, is limited to Elovl2, at least in mammals. Elovl5 enzymes have been characterised from seventeen fish species but Elovl2 enzymes have only been characterised in two of these fish. The essentiality of Elovl2 for DHA synthesis is unknown in fish. This study is the first to identify an Elovl2 in rainbow trout (Oncorhynchus mykiss) and functionally characterise the Elovl5 and Elovl2 using a yeast expression system. Elovl5 was active with C18–20 PUFA substrates and not C22 PUFA. In contrast, Elovl2 was active with C20–22 PUFA substrates and not C18 PUFA. Thus, rainbow trout is dependent on Elovl2 for DPA to 24:5n  3 synthesis and ultimately DHA synthesis. The expression of elovl5 was significantly higher than elovl2 in liver. Elucidating this dependence on Elovl2 to elongate DPA and the low elovl2 gene expression compared with elovl5 are critical findings in understanding the potential for rainbow trout to synthesize DHA.  相似文献   

12.
The present study is the first report demonstrating that ionic liquids consisting of cholinium cations and linear carboxylate anions ([Ch][CA] ILs) can be used for pretreatment of lignocellulosic materials to enhance subsequent enzymatic saccharification. Six variants of [Ch][CA] ILs were systematically prepared by combining cholinium cations with linear monocarboxylate anions ([CnH2n+1–COO], n = 0–2) or dicarboxylate anions ([HOOC–CnH2n+1–COO], n = 0–2). These [Ch][CA] ILs were analyzed for their toxicity to yeast cell growth and their ability to pretreat kenaf powder for subsequent enzymatic saccharification. When assayed against yeast growth, the EC50 for choline acetate ([Ch][OAc]) was 510 mM, almost one order of magnitude higher than that for 1-ethyl-3-methylimidazolium acetate ([Emim][OAc]). The cellulose saccharification ratio after pretreatment at 110 °C for 16 h with [Ch][OAc] (100.6%) was almost comparable with that after pretreatment with [Emim][OAc]. Therefore, [Ch][OAc] is a biocompatible alternative to [Emim][OAc] for lignocellulosic material pretreatment.  相似文献   

13.
A rapid, specific and sensitive liquid chromatography–electrospray ionization-tandem mass spectrometry method was developed and validated for determination of cymipristone in human plasma. Mifepristone was used as the internal standard (IS). Plasma samples were deproteinized using methanol. The compounds were separated on a ZORBAX SB C18 column (50 mm × 2.1 mm i.d., dp 1.8 μm) with gradient elution at a flow-rate of 0.3 ml/min. The mobile phase consisted of 10 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadruple tandem mass spectrometer by selective reaction monitoring (SRM) mode via electrospray ionization. Target ions were monitored at [M+H]+ m/z 498  416 and 430  372 in positive electrospray ionization (ESI) mode for cymipristone and IS, respectively. Linearity was established for the range of concentrations 0.5–100 ng/ml with a coefficient correlation (r) of 0.9996. The lower limit of quantification (LLOQ) was identifiable and reproducible at 0.5 ng/ml. The validated method was successfully applied to study the pharmacokinetics of cymipristone in healthy Chinese female subjects.  相似文献   

14.
A reverse-phase liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) method was developed and validated for determination of aminoflavone (AF) in human plasma. Sample preparation involved a liquid–liquid extraction by the addition of 0.25 mL of plasma with 1.0 mL ethyl acetate containing 50 ng/mL of the internal standard zileuton. The analytes were separated on a Waters X-Terra? MS C18 column using a mobile phase consisting of methanol/water containing 0.45% formic acid (70:30, v/v) and isocratic flow at 0.2 mL/min for 6 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the AF concentration range of 5–2000 ng/mL in human plasma. The lower limit of quantitation (LLOQ) was 5 ng/mL for AF in human plasma. The accuracy and within- and between-day precisions were within the generally accepted criteria for bioanalytical method (<15%). This method was successfully applied to characterize AF plasma concentration-time profile in the cancer patients in a phase I trial.  相似文献   

15.
New ionic liquid-modified silica sorbents were developed by the surface chemical modification of the commercial silica using synthesized ionic liquids. The obtained ionic liquid-modified particles were successfully used as a special sorbent in solid-phase extraction process to isolation of cryptotanshinone, tanshinone I and tanshinone IIA from Salvia Miltiorrhiza Bunge. Different washing and elution solvents such as water, methanol and methanol–acetic acid (90/10, v/v) were evaluated. A comparison of ionic liquid-modified silica cartridges and traditional silica cartridge show that higher recovery was observed using ionic liquid-modified silica sorbents. A quantitative analysis was conducted by high-performance liquid chromatography using a C18 column (5 μm, 150 mm × 4.6 mm) with methanol–water (78:22, v/v, and containing 0.5% acetic acid) as a mobile phase. Good linearity was obtained from 0.5 × 10?4 to 0.5 mg/mL (r2 > 0.999) with the relative standard deviations less than 4.8%.  相似文献   

16.
Galinsoga ciliata Raf. Blake like Galinsoga parviflora Cav., comes from the Andes region. The chemical composition, activity and use are similar for both species. Galinsoga species are used in folk medicine as anti-inflammatory agents and accelerators for wound healing. Extracts are applied topically onto the skin to treat dermatological diseases, eczemas, lichens and hard-healing-wounds, and also to treat snakebites. Orally they used to cure flu and colds.In the studies using HPTLC method, different stationary phases, including unmodified silica gel, silica gels modified with CN, NH2, DIOL and RP18 groups were tried. The best separation of the tested compounds was achieved on silica gel plates, when as mobile phases mixtures – ethyl acetate–acetic acid–formic acid–water (100:11:11:26, v/v/v/v), ethyl acetate–methanol–formic acid–water (50:3:4:6, v/v/v/v) and ethyl acetate–methyl ethyl ketone–formic acid–water (30:9:3:3, v/v/v/v) – were used. Using reference substances, in the examined extracts the presence of flavonoids: patulitrin, quercimeritrin, quercitagetrin, and phenolic acids – caffeic and chlorogenic acids was found.HPLC analyses of extracts were carried out on a reversed-phase Zorbax SB column (150 mm × 2.1 mm, 1.9 μm). The mobile phase (A) was water/acetonitrile/formic acid (95:5:0.1, v/v/v) and the mobile phase (B) was acetonitrile/formic acid (100:0.1, v/v). A linear gradient system was used: 0–30 min, 1–30% B. Application of HPLC-DAD-MS method confirmed the results obtained by HPTLC method. Moreover, in the tested extracts the presence of caffeoylglucaric acids as dominating compounds was detected.  相似文献   

17.
We present a simple, rapid, and sensitive liquid chromatography (LC)–tandem mass spectrometry (MS/MS) method for the simultaneous quantification of rosiglitazone and its two major metabolites via CYP2C8/9, N-desmethyl and p-hydroxy rosiglitazone, in human plasma. The procedure was developed and validated using rosiglitazone-d3 as the internal standard. Plasma samples (0.1 ml) were prepared using a simple deproteinization procedure with 0.2 ml of acetonitrile containing 40 ng/ml of rosiglitazone-d3. Chromatographic separation was carried out on a Luna C18 column (100 mm × 2.0 mm, 3-μm particle size) using an isocratic mobile phase consisting of a 60:40 (v/v) mixture of acetonitrile and 0.1% formic acid(aq). Each sample was run at 0.2 ml/min for a total run time of 2.5 min per sample. Detection and quantification were performed using a mass spectrometer in selected reaction-monitoring mode with positive electrospray ionization at m/z 358.1  135.1 for rosiglitazone, m/z 344.2  121.1 for N-desmethyl rosiglitazone, m/z 374.1  151.1 for p-hydroxy rosiglitazone, and m/z 361.1  138.1 for rosiglitazone-d3. The linear ranges of concentration for rosiglitazone, N-desmethyl rosiglitazone, and p-hydroxy rosiglitazone were 1–500, 1–150, and 1–25 ng/ml, respectively, with a lower limit of quantification of 1 ng/ml for all analytes. The coefficient of variation for assay precision was less than 14.4%, and the accuracy was 93.3–112.3%. No relevant cross-talk and matrix effect were observed. This method was successfully applied to a pharmacokinetic study after oral administration of a 4-mg rosiglitazone tablet to healthy male Korean volunteers.  相似文献   

18.
A sensitive, specific and selective method has been developed for the simultaneous determination of bisoprolol and hydrochlorothiazide in human plasma. The method employed a state of the art LC–MS/MS operated in the positive and negative ionization switching modes. A simple sample preparation step involving protein precipitation with acetonitrile has been optimized; the analytes and the internal standard moxifloxacin were separated on a Purosphere® STAR C8 column (125 mm × 4 mm, 5 μm). The mobile phase was an ammonium acetate solution (1 mM) with formic acid (0.2%): methanol and acetonitrile (65:17.5:17.5, v/v/v (%)), the flow rate was set at 0.65 mL/min. Bisoprolol and hydrochlorothiazide were ionized using ESI source prior to detection by Multiple Reaction Monitoring (MRM) mode while monitoring at the following transitions: positive m/z 326  116 for bisoprolol, negative m/z 296  269 and m/z 296  205 for hydrochlorothiazide. Linearity was demonstrated over the concentration range 0.10–30.0 (ng/mL) for bisoprolol and 1.00–80.00 ng/mL for hydrochlorothiazide. The limits of detection were 0.100 (ng/mL) for bisoprolol and 1.00 (ng/mL) for hydrochlorothiazide. The validated method was successfully applied to a pharmacokinetic study of 5 mg bisoprolol fumarate with 12.5 mg hydrochlorothiazide tablet in healthy volunteers.  相似文献   

19.
Pyrrole (Py)–imidazole (Im) polyamides synthesized by combining N-methylpyrrole and N-methylimidazole amino acids have been identified as novel candidates for gene therapy. In this study, a sensitive method using liquid chromatography–tandem mass spectrometry (LC–MS/MS) with an electrospray ionization (ESI) source was developed and validated for the determination and quantification of Py–Im polyamide in rat plasma. Py–Im polyamide was extracted from rat plasma by solid-phase extraction (SPE) using a Waters Oasis® HLB cartridge. Separation was achieved on an ACQUITY UPLC HSS T3 (1.8 μm, 2.1 × 50 mm) column by gradient elution using acetonitrile:distilled water:acetic acid (5:95:0.1, v/v/v) and acetonitrile:distilled water:acetic acid (95:5:0.1, v/v/v). The method was validated over the range of 10–1000 ng/mL and the lower limit of quantification (LLOQ) was 10 ng/mL. This method was successfully applied to the investigation of the pharmacokinetics of Py–Im polyamide after intravenous administration.  相似文献   

20.
Gambogic acid (GA), a promising anticancer candidate, is a polyprenylated xanthone abundant in the resin of Garcinia morella and Garcinia hanburyi. The major circulating metabolite of GA in human, 10-hydroxygambogic acid (10-OHGA), was identified by comparison of the retention time and mass spectra with those of reference standard using liquid chromatography–tandem mass spectrometry. The reference standard of 10-OHGA was isolated from bile samples of rats after intravenous injection of GA injection, and its structure was confirmed by NMR. Then, a selective and sensitive method was developed for the quantitative determination of this metabolite in human plasma. After liquid–liquid extraction by ethyl acetate, the analyte and the internal standard were separated on a Sepax HPC18 column (100 mm × 2.1 mm i.d., 3.0 μm) with a mobile phase of 10 mM ammonium acetate water solution containing 0.1% formic acid–acetonitrile (20:80, v/v). The detection was performed on a single quadrupole mass spectrometer equipped with electrospray ionization (ESI) source. The calibration curve was linear over the range of 3–2000 ng/mL for 10-OHGA. The developed quantification method can now be used for the pharmacokinetic and pharmacological studies of 10-OHGA after intravenous infusion of GA injection in human.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号