首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A high-throughput on-line capillary array-based two-dimensional liquid chromatography (2D-LC) system coupled with MALDI-TOF-TOF-MS proteomics analyzer for comprehensive proteomic analyses has been developed, in which one capillary strong-cation exchange (SCX) chromatographic column was used as the first separation dimension and 18 parallel capillary reversed-phase liquid chromatographic (RPLC) columns were integrated as the second separation dimension. Peptides bound to the SCX phase were "stepped" off using multiple salt pulses followed by sequentially loading of each subset of peptides onto the corresponding precolumns. After salt fractionation, by directing identically split solvent-gradient flows into 18 channels, peptide fractions were concurrently back-flushed from the precolumns and separated simultaneously with 18 capillary RP columns. LC effluents were directly deposited onto the MALDI target plates through an array of capillary tips at a 15-s interval, and then alpha-cyano-4-hydroxycinnamic acid (CHCA) matrix solution was added to each sample spot for subsequent MALDI experiments. This new system allows an 18-fold increase in throughput compared with serial-based 2D-LC system. The high efficiency of the overall system was demonstrated by the analysis of a tryptic digest of proteins extracted from normal human liver tissue. A total of 462 proteins was identified, which proved the system's promising potential for high-throughput analysis and application in proteomics.  相似文献   

2.
A highly sensitive and selective method has been developed and validated to determine limaprost, a prostaglandin (PG) E(1) analogue, in human plasma by on-line two-dimensional reversed-phase liquid chromatography-tandem mass spectrometry (2D-LC/MS/MS) due to the lack of efficient methods to determine very low levels of limaprost in plasma. Limaprost and its deuterium derivatives, used as internal standard, were extracted by protein precipitation and following three-step solid phase extractions. After extraction procedure, samples were analyzed by on-line 2D-LC/MS/MS with electrospray ionization in negative mode. The 2D-LC system consists of Phenyl column at first dimension and ODS at second dimension with a trapping column placed between the separation columns. The linear dynamic range of this method was 0.1-10 pg/ml with 3 ml of plasma (r >0.9987). Acceptable precision and accuracy were obtained over the calibration curve ranges. The assay has been successfully used in analyses of human plasma samples to support clinical pharmacokinetics studies.  相似文献   

3.
Proteomics has become an essential methodology for large-scale analysis of proteins in various fields of plant biology. We compared two proteomics techniques, two-dimensional liquid chromatography (2D-LC) and fluorescence two-dimensional difference gel electrophoresis (2D-DIGE), for their ability to identify proteins regulated by gibberellin (GA) in rice. Two-week-old rice seedlings were treated with or without 5 microM GA3 for 48 h and proteins extracted from the basal region of the leaf sheath. After separation of the proteins by the two techniques, the amino acid sequences of GA3-responsive proteins were analyzed using a protein sequencer and mass spectrometry. 2D-LC and 2D-DIGE were able to resolve 1248 protein fractions and 1500 proteins, respectively. Out of these, 2D-LC identified 9 proteins that were up-regulated and 9 that were down-regulated by GA treatment; 2D-DIGE identified 4 up-regulated and 4 down-regulated proteins. The two techniques detected overlapping sets of proteins. For example, cytosolic glyceraldehyde-3-phosphate dehydrogenase and photosystem II oxygen-evolving complex protein were identified as GA3-regulated proteins by both methods. In addition, these two methods uncovered GA3-regulated unknown proteins which had not been reported previously, and novel proteins which are not detected in 2D-PAGE followed by Coomassie brilliant blue staining. These results suggest that these two methods are among some of the very useful tools for detecting proteins that may function in various physiological and developmental processes in plants.  相似文献   

4.
We report a new design of a fully automated, high-efficiency parallel nonsplit nanoflow capillary HPLC system, coupled on-line with linear ion trap (LTQ) and high performance nanoelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nanoESI LTQ-FTICR MS). The system, intended for high-throughput proteome analysis of complex protein mixtures, notably serum and plasma, consists of two reversed-phase trap columns for large volume sample injection with high speed sample loading and desalting and two reversed-phase analytical capillary columns. Through a nanoscale two-position, 10-port switching valve, the whole system is terminated by a 10 microm i.d. of nanoemitter mounted on the nanoelectrospray source in front of the sampling cone of the LTQ-FTICR MS. Gradient elution to both nanoflow-rate capillary columns is simultaneously delivered by a single HPLC system via two independent binary gradient pump systems. The parallel capillary column approach eliminates the time delays for column regeneration/equilibration since one capillary column is used for separating the sample mixtures and delivering the separated fractions to the MS, while the other capillary column is being regenerated and equilibrated. The reproducibility of retention time and peak intensity of the present automated parallel nanoflow-rate capillary HPLC system is comparable to that obtained using a single column configuration. Replicate injections of tryptic digests indicated that this system provided good reproducibility of retention time and peak area on both columns with average CV values of less than 1.08% and 7.04%, respectively. Throughput was increased to 100% for 2-h LC-MS analysis compared to the single capillary column LC-MS pipeline. Application of this system is demonstrated in a plasma proteomic study. A total of 312 868 MSMS events were acquired and 1564 proteins identified with high confidence (Protein Prophet > or = 0.9, and peptides matched > or = 2). Comparison of a series of plasma fractions run using the single-column LC-MS versus the parallel-column LC-MS demonstrated that parallel-column LC-MS system significantly reduced the sample carryover, improved MS data quality and increased the number of MS/MS sequence scan events.  相似文献   

5.
In this study, a label-free relative quantification strategy was developed for quantifying low-abundance glycoproteins in human serum. It included three steps: (1) immunodepletion of 12 high-abundance proteins, (2) enrichment of low-abundance glycoproteins by multi-lectin column, (3) relative quantification of them between different samples by micrOTOF-Q. We also evaluated the specificity and efficiency of immunodepletion, the accuracy of protein quantification and the possible influence of immunodepletion, glycoprotein enrichment, trypsin digestion and peptide ionization on quantification. In conclusion, the relative quantification method can be effectively applied to the screening of low-abundance biomarkers.  相似文献   

6.
Chan LL  Lo SC  Hodgkiss IJ 《Proteomics》2002,2(9):1169-1186
A comprehensive study to find the optimal sample preparation conditions for two-dimensional electrophoresis (2-DE) analysis of Prorocentrum triestinum, a model causative agent of harmful algal blooms (HABs) was carried out. The four major sample preparation steps for 2-DE: (a) cell disruption: i.e. sonication and homogenization with glass beads; (b) protein extraction : i.e. sequential and independent extraction procedures; (c) pre-electrophoretic treatment: these included (i) treatment with RNAase/DNAase or benzonase; (ii) ultracentrifugation to sediment large macromolecules such as DNA; (iii) desalting and concentration by ultrafiltration through a Microcon centrifugal filter device (MWCO: 3000 daltons); and (iv) desalting by a micro BioSpin chromatography column (MWCO: 6000 daltons); and (d) rehydration buffers, reducing agents and sample application in the first dimension isoelectric focussing were studied. Our results showed that sonication is easy to perform and resulted in a higher protein yield. Among the four extraction buffers, the urea containing buffers resulted in the extraction of the highest amount of protein while tris(hydroxymethyl)aminomethane buffers and trichloroacetic acid (TCA)/acetone precipitation allowed detection of a higher number of protein species (i.e. protein spots). Desalting by BioSpin and ultrafiltration have improved the 2-DE resolution of the water soluble fraction but have less effect on urea containing fractions. TCA/acetone precipitation was able to desalt all protein fractions independent of the extraction media, however extended exposure to this low pH medium has caused protein modification. Introduction of either DNase/RNase or benzonase treatment did not improve the discriminatory power of the 2-DE but this treatment did yield 2-DE with the clearest background. Proteolytic digestion was inhibited by addition of a protease inhibitor cocktail. Taken overall, a combination of sequential extraction and desalting by BioSpin chromatography for sample treatment before first dimension of 2-DE gave best results based on its simplicity and minimal protein loss. Finally, triscarboxyethylphosphine (TCEP) has performed well as a reducing agent in both the rehydration and equilibration buffers. The rehydration buffer found to be best in this study was 8.0 M urea, 2% 3-[(3-cholamidoprphyldimethylamino]-1-propanesulfonate, 4 mM TCEP and 1% immobilized pH gradient buffer. Subsequently, we applied this finding and performed 2-DE analysis on the soluble protein fractions extracted from light-starved cultured algal cells (nonblooming) and cultured cells grown under optimal conditions (blooming). 2-DE maps of these algal cultures were visibly different and many differentially expressed proteins were found.  相似文献   

7.
Human plasma consists of mainly large proteins, which vary in terms of both composition and concentration with the physiological state of the individual. Alterations in protein concentrations reflect the current state of the individual's health and thus may be utilized as valuable biomarkers for a specific biological process or disease. Two-dimensional gel electrophoresis (2-DE) has proven to be a valuable method for the separation and comparison of complex protein mixtures, for example, from disease and healthy states, as this method provides information regarding the variation, relative quantities, and structures of the intact proteins. The procedures utilized for the preparation of samples for 2-DE are critical to the acquisition of high-quality results for the discovery of biomarkers. The objective of this study was to review the preparation methods of plasma for 2-DE, particularly those designed to improve the detection of proteins in low abundance in plasma on 2-DE. The use of anticoagulants and protease inhibitors during the collection of blood, the removal of abundant proteins using multicomponent immunodepletion system, and desalting procedure allow us to compile profiles of proteins occurring in low concentrations in the plasma and to improve the pattern generated during 2-DE.  相似文献   

8.
Protein identification plays an important role in today's academic and industrial proteomic research. Commonly used methods for the separation of proteins from complex samples include liquid chromatography (e.g., ion exchange, reversed-phase, hydrophobic interaction), or types of gel electrophoresis (e.g., 1d and 2d PAGE). Relevant proteins separated in the latter way are often cut out, cleaved with trypsin "in gel," and the resulting peptide mixtures combined with matrix and spotted onto a target plate for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF-ms) analysis. Subsequently, proteins can be identified by comparison of the resulting peptide mass fingerprints against different databases.(1) since the success of protein identification can be enhanced by the desalting and concentration of the samples, an innovative C18-membrane was incorporated into a microspin column (Vivapure C18 micro spin column, Vivascience AG, Hannover, Germany) to analyze its performance for sample preparation prior to MALDI-ToF-ms. Rapid concentration of single or multiple 200-microl volumes through an available membrane only 2 mm in diameter allowed for analysis of very dilute samples. We observed the successful and rapid desalting of urea-containing protein samples at 100 fmol/mul up to a mass of approximately 70 KDA and the concentration of digest peptides from a solution of 1 fmol/microl using C18-membrane technology.  相似文献   

9.
Commercially available desalting techniques, necessary for downstream MALDI-TOF analysis of proteins, are often costly or time consuming for large-scale analysis. Here, we present techniques to elute proteins from various affinity resins, free from salt and ready for MALDI mass spectrometry. We showed that 0.1% TFA in 50% acetonitrile or 40% ethanol can be used as salt-free eluents for His-tagged proteins from variety of polyhistidine-affinity resins, while washing of resin beads twice with double-distilled water prior to the elution effectively desalted and recovered wide-range-molecular size proteins than commercially available desalting devices. Modified desalting and elution techniques were also applied for Flag- and Myc-tag affinity resins. The technique was further applied in co-precipitation assay, where the maximum recovery of wide-range molecular size proteins is crucial. Further, results showed that simple washing of the beads with double distilled water followed by elution with acetonitrile effectively desalted and recovered 150 kDa factor H protein of the sheep and its binding partner ~30 kDa BbCRASP-1 in co-precipitation assay. In summary, simple modifications in the desalting and elution strategy save time, labor and cost of the protein preparation for MALDI mass spectrometry; and large-scale protein purifications or co-precipitations can be performed with ease.  相似文献   

10.
In clinical and diagnostic proteomics, it is essential to develop a comprehensive and robust system for proteome analysis. Although multidimensional liquid chromatography/tandem mass spectrometry (LC/MS/MS) systems have been recently developed as powerful tools especially for identification of protein complexes, these systems still some drawbacks in their application to clinical research that requires an analysis of a large number of human samples. Therefore, in this study, we have constructed a technically simple and high throughput protein profiling system comprising a two-dimensional (2D)-LC/MS/MS system which integrates both a strong cation exchange (SCX) chromatography and a microLC/MS/MS system with micro-flowing reversed-phase chromatography. Using the microLC/MS/MS system as the second dimensional chromatography, SCX separation has been optimized as an off-line first dimensional peptide fractionation. To evaluate the performance of the constructed 2D-LC/MS/MS system, the results of detection and identification of proteins were compared using digests mixtures of 6 authentic proteins with those obtained using one-dimensional microLC/MS/MS system. The number of peptide fragments detected and the coverage of protein sequence were found to be more than double through the use of our newly built 2D-LC/MS/MS system. Furthermore, this multidimensional protein profiling system has been applied to plasma proteome in order to examine its feasibility for clinical proteomics. The experimental results revealed the identification of 174 proteins from one serum sample depleted HSA and IgG which corresponds to only 1 microL of plasma, and the total analysis run time was less than half a day, indicating a fairly high possibility of practicing clinical proteomics in a high throughput manner.  相似文献   

11.
Recombinant monoclonal antibodies (MAbs) have become one of the most rapidly growing classes of biotherapeutics in the treatment of human disease. MAbs are highly heterogeneous proteins, thereby requiring a battery of analytical technologies for their characterization. However, incompatibility between separation and subsequent detection is often encountered. Here we demonstrate the utility of a generic on-line liquid chromatography–mass spectrometry (LC-MS) method operated in a two-dimensional format toward the rapid characterization of MAb charge and size variants. Using a single chromatographic system capable of running two independent gradients, up to six fractions of interest from an ion exchange (IEC) or size exclusion (SEC) separation can be identified by trapping and desalting the fractions onto a series of reversed phase trap cartridges with subsequent on-line analysis by mass spectrometry. Analysis of poorly resolved and low-level peaks in the IEC or SEC profile was facilitated by preconcentrating fractions on the traps using multiple injections. An on-line disulfide reduction step was successfully incorporated into the workflow, allowing more detailed characterization of modified MAbs by providing chain-specific information. The system is fully automated, thereby enabling high-throughput analysis with minimal sample handling. This technology provides rapid data turnaround time, a much needed feature during product characterization and development of multiple biotherapeutic proteins.  相似文献   

12.
取8周龄羊草的地上部分,用三氯乙酸-丙酮法沉淀总蛋白,沉淀裂解后将缓冲液置换为起始缓冲液,进行第一维色谱聚焦分离。将第一维分离收集的pH值为8.5至4.0之间的组分分别进行第二维无孔硅胶反相高效液相色谱分离,利用ProteoVue软件获得羊草植株总蛋白pI/UV图谱,即羊草植株总蛋白质表达谱。文中对二维液相色谱法分离羊草蛋白质进行了方法学的研究,在第二维分离中尝试用3种不同的洗脱梯度条件进行分离,优化二维液相色谱分离条件并与传统凝胶双向电泳进行了比较,另外还对二维液相色谱的重现性和准确性进行了检验。实验建立了利用二维液相色谱分离羊草总蛋白的技术方法。  相似文献   

13.
He W  Huang C  Luo G  Dal Prà I  Feng J  Chen W  Ma L  Wang Y  Chen X  Tan J  Zhang X  Armato U  Wu J 《Proteomics》2012,12(7):1059-1072
Just as biomarkers specific for diseases, biomarkers indicative of healthy conditions are valuable for the early diagnosis, monitoring, and prognosis of diseases. Our study focused on discovering via proteomics a stable panel of urinary proteins in the human healthy population. Urine samples were collected three times during 4 months from 100 male and 100 female healthy donors and analyzed through four different fractionation techniques (i.e. in-gel, 2D-LC, OFFGEL, and mRP) coupled with HPLC-Chip-MS/MS. Thus, 1641 urinary proteins were identified with a high confidence, among which 70 exhibiting an intergender/day variation <0.25 were selected and matched with the previously published five largest urinary proteomes to get 56 candidate proteins. Next, a panel comprising 18 intact urinary proteins was constructed by comparing the urinary proteomes via SDS-PAGE and 2DE. Finally, such 18 urinary proteins were validated via enzyme-linked immunosorbent assay in eight healthy individuals. Most of these proteins had been related to multiple rather than to single diseases. Therefore, we surmise that this protein set could be used as a biomarker to assess the human health status. Further determinations of the normal fluctuations of the single urinary proteins in this series using samples from large numbers of healthy individuals are required prior to any application in clinical settings.  相似文献   

14.
Ion-exchange chromatography has been applied to purification of unsaturated oligoglucuronans. After an isocratic elution on a strong anion-exchange column, the collected fractions were desalted by low pressure size exclusion chromatography. However, this efficient separation was limited by the time required to desalt. So, we developed a reversed-phase chromatography method using back ionization of oligomers. Two C18 columns were tested with trifluoroacetic acid (TFA 0.7%) as eluent. Different selectivities and column stabilities were observed in this acidic condition. The scale up for semi-preparative applications enabled us to recover pure unsaturated oligoglucuronans without desalting step.  相似文献   

15.
In clinical and pharmaceutical proteomics, serum and plasma are frequently used for detection of early diagnostic biomarkers for therapeutic targets. Although obtaining these body fluid samples is non-invasive and easy, they contain some abundant proteins that mask other protein components present at low concentrations. The challenge in identifying serum biomarkers is to remove the abundant proteins, uncovering and enriching at the same time the low-abundance ones. The depletion strategies, however, could lead to the concomitant removal of some non-targeted proteins that may be of potential interest. In this study, we compared three different methods aimed to deplete high-abundance proteins from human serum, focusing on the identification of non-specifically bound proteins which might be eventually removed. A Cibacron blue-dye-based method for albumin removal, an albumin and IgG immunodepletion method and an immunoaffinity column (Multiple Affinity Removal System) that simultaneously removes a total of six high-abundance proteins, were investigated. The bound proteins were eluted, separated by two-dimensional gel electrophoresis and identified by Nano LC-CHIP-MS system. Flow-through fractions and bound fractions were also analysed with the ProteinChip technology SELDI-TOF-MS. Our results showed that the methods tested removed not only the targeted proteins with high efficiency, but also some non-targeted proteins. We found that the Multiple Affinity Removal Column improved the intensity of low-abundance proteins, displayed new protein spots and increased resolution. Notably, the column showed the lowest removal of untargeted proteins, proved to be the most promising depletion approach and a reliable method for serum preparation prior to proteomic studies.  相似文献   

16.
Evaluation of cellular processes and their changes at the level of protein expression and post-translational modifications may allow identification of novel proteins and the mechanisms involved in pathogenic processes. However, the number of proteins and, after tryptic digestion, of peptides from a single cell can be tremendously high. Separation and analysis of such complex peptide mixtures can be performed using multidimensional separation techniques such as two-dimensional gel electrophoresis or two-dimensional-high-performance liquid chromatography (2-D-HPLC). The aim of this work was to establish a fully automated on-line 2-D-HPLC separation method with column switching for the separation of complex tryptic digests. A model mixture of five proteins as well as a nuclear matrix protein sample were digested with trypsin and separated using a strong cation exchange (SCX) column in the first dimension and nano reversed phase in the second dimension. Separated peptides were detected using an ion trap mass spectrometer. The advantages of this new fully automated method are rapid sample loading, the possibility of injecting large volumes and no introduction of salt into the mass spectrometer. Furthermore, column switching allows the independent control and optimization of the two dimensions independently.  相似文献   

17.
Immunodepletion of clinical fluids to overcome the dominance by a few very abundant proteins has been explored but studies are few, commonly examining only limited aspects with one analytical platform. We have systematically compared immunodepletion of 6, 14, or 20 proteins using serum from renal transplant patients, analysing reproducibility, depth of coverage, efficiency, and specificity using 2-D DIGE ('top-down') and LC-MS/MS ('bottom-up'). A progressive increase in protein number (≥2 unique peptides) was found from 159 in unfractionated serum to 301 following 20 protein depletion using a relatively high-throughput 1-D-LC-MS/MS approach, including known biomarkers and moderate-lower abundance proteins such as NGAL and cytokine/growth factor receptors. On the contrary, readout by 2-D DIGE demonstrated good reproducibility of immunodepletion, but additional proteins seen tended to be isoforms of existing proteins. Depletion of 14 or 20 proteins followed by LC-MS/MS showed excellent reproducibility of proteins detected and a significant overlap between columns. Using label-free analysis, greater run-to-run variability was seen with the Prot20 column compared with the MARS14 column (median %CVs of 30.9 versus 18.2%, respectively) and a corresponding wider precision profile for the Prot20. These results illustrate the potential of immunodepletion followed by 1-D nano-LC-LTQ Orbitrap Velos analysis in a moderate through-put biomarker discovery process.  相似文献   

18.
The thrombolytic, recombinant tissue plasminogen activator (rt-PA) is the only approved therapy for acute ischemic stroke (AIS). When administered after AIS, rt-PA has many adverse pleiotropic actions, which are currently poorly understood. The identification of proteins showing differential expression after rt-PA administration may provide insight into these pleiotropic actions. In this study we used a 2D-LC MS/MS iTRAQ proteomic analysis, western blotting, and pathway analysis to analyze changes in protein expression 24-hours after rt-PA administration in the cortical brain tissue of 36 rats that underwent a sham or transient middle cerebral artery occlusion surgery. After rt-PA administration we reported alterations in the expressions of 18 proteins, many of which were involved in excitatory neurotransmitter function or cytoskeletal structure. The expression changes of GAD2 and EAAT1 were validated with western blot. The interactions between the identified proteins were analyzed with the IPA pathway analysis tool and three proteins: DPYSL2, RTN4, and the NF-kB complex, were found to have characteristics of being key proteins in the network. The differential protein expressions we observed may reflect pleiotropic actions of rt-PA after experimental stroke, and shine light on the mechanisms of rt-PA''s adverse effects. This may have important implications in clinical settings where thrombolytic therapy is used to treat AIS.  相似文献   

19.
Differences among techniques for high-abundant protein depletion   总被引:3,自引:0,他引:3  
The need to identify protein or peptide biomarkers via readily available biological samples like serum, plasma, or cerebrospinal fluid is often hindered by a few particular proteins present at relatively high concentrations. The ability to remove these proteins specifically, reproducibly, and with high selectivity is increasingly important in proteomic studies, and success in this procedure is leading to an ever-increasing list of lower abundant proteins being identified in these biological fluids. The current work addresses some of the potential problems in depleting proteins in typical biomarker studies, including nonspecific binding during depletion procedures and whether low molecular weight (LMW) species bind to the column in a so-called "sponge" effect caused by the ability of albumin or other high-abundant proteins to bind peptides or protein fragments. LC-MS/MS methods were applied to the comparative analysis of an IgG-based immunodepletion method and a Cibacron blue (CB)-dye-based method, for specificity of removing targeted proteins (binding fraction), as well as for assessing efficiency of target removal. This analysis was extended to examine the effects of repeated use of materials (cycles of binding and elution), in order to assess potential for carryover of one sample to the next. Capacity studies and efficiency of protein removal from the serum samples were followed for the IgG-based system using both immunochemical assays (ELISA) as well as LC-MS/MS methods. Additionally, the IgG-based system was further characterized for the removal of LMW polypeptides by nonspecific binding. We conclude that the IgG-based system provided effective removal of targeted proteins, with minimal carryover, high longevity, and minimal nonspecific binding. Significant differences are noted between the depletion techniques employed, and this should be considered based on the expectations set during experimental design.  相似文献   

20.
Gong Y  Li X  Yang B  Ying W  Li D  Zhang Y  Dai S  Cai Y  Wang J  He F  Qian X 《Journal of proteome research》2006,5(6):1379-1387
Plasma proteins may often serve as indicators of disease and are a rich source for biomarker discovery. However, the intrinsic large dynamic range of plasma proteins makes the analysis very challenging because a large number of low abundance proteins are often masked by a few high abundance proteins. The use of prefractionation methods, such as depletion of higher abundance proteins before protein profiling, can assist in the discovery and detection of less abundant proteins that may ultimately prove to be informative biomarkers. But there are few studies on comprehensive investigation of the proteins both in the fractions depleted and remainder. In the present study, two different immunoaffinity fractionation columns for the top-6 or the top-12 proteins in plasma were investigated and both the proteins in column-bound and flow-through fractions were subsequently analyzed. A two-dimensional peptide separation strategy, utilizing chromatographic separation techniques, combined with tandem mass spectrometry (MS/MS) was employed for proteomic analysis of the four fractions. Using the established HUPO PPP criteria, a total of 2401 unique plasma proteins were identified. The Multiple Affinity Removal System yielded 921 and 725 unique proteins from the flow-through and bound fractions, respectively, whereas the Seppro MIXED 12 column yielded identification of 897 and 730 unique proteins from the flow-through and bound fractions, respectively. When more stringent criteria, based on searching against the reversed database, were implemented, 529 unique proteins were identified from the four fractions with the confidence in peptide identification increased from 73.6% to 99%. To determine whether the presence of nontarget proteins in the immunoaffinity-bound fraction could be attributed to their interaction with high abundance proteins, co-immunoprecipitation analysis with an antibody to human plasma albumin was performed, which resulted in an identification of 40 unique proteins from the coimmunoprecipitate with the more stringent criteria. This study illustrated that combining the column-bound and flow-through fractions from immunoaffinity separation affords more extensive profiling of the protein content of human plasma. The presence of nontarget proteins in the column-bound fractions may be induced by their binding to the higher abundance proteins targeted by the immunoaffinity column.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号