共查询到20条相似文献,搜索用时 15 毫秒
1.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,750(1):51-60
Unilamellar liposomes with entrapped fluorescent dye calcein were stably immobilized in gel beads by avidin–biotin-binding. The immobilized liposomes remained extremely stable upon storage and chromatographic runs. The immobilized calcein-entrapped liposomes were utilized for fluorescent analysis of solute–membrane interactions, which in some cases are too weak to be detected by chromatographic retardation. A liposome column was used as a sensitive probe to detect the interactions of membranes with pharmaceutical drugs, peptides and proteins. Retardation of the solutes was monitored using a UV detector. Perturbation of the membranes, reflected as leakage of the entrapped calcein by some of the solutes, can thus be detected on-line using a flow-fluorescent detector. For the amphiphilic drugs or synthetic peptides, perturbation of membranes became more pronounced when the retardation (hydrophobicity) of the molecules increased. On the other hand, in the case of positively-charged peptides, polylysine, or partially denatured bovine carbonic anhydrase, significant dye leakage from the liposomes was observed although the retardation was hardly to be measured. Weak protein–membrane interactions can thus be assumed from the large leakage of calcein from the liposomes. This provides additional useful information for solute–membrane interactions, as perturbation of the membranes was also indicated by avidin–biotin-immobilized liposome chromatography (ILC). 相似文献
2.
M. Ann D.N. Perera Suh-Yeon Choi Eve Syrkin Wurtele Basil J. Nikolau 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2009,877(5-6):482-488
Because acyl-CoAs play major roles in numerous anabolic and catabolic pathways, the quantitative determination of these metabolites in biological tissues is paramount to understanding the regulation of these metabolic processes. Here, we report a method for the analysis of a collection of short-chain acyl-CoAs (<6 carbon chain length) from plant extracts. Identification of each individual acyl-CoA was conducted by monitoring specific mass-fragmentation ions that are derived from common chemical moieties of all Coenzyme A (CoA) derivatives, namely the adenosine triphosphate nucleotide, pantothenate and acylated cysteamine. This method is robust and quick, enabling the quantitative analysis of up to 12 different acyl-CoAs in plant metabolite extracts with minimal post-extraction processing, using a 30 min chromatographic run-time. 相似文献
3.
Hans von Stedingk Per Rydberg Margareta Törnqvist 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(27):2483-2490
A rapid and sensitive method using liquid chromatography–tandem mass spectrometry (LC–MS/MS) for simultaneous determination of adducts from acrylamide, glycidamide and ethylene oxide to N-terminal valines in hemoglobin (Hb) was developed. This new procedure is based on the same principles as the N-alkyl Edman procedure for analysis of adducts from electrophilic agents to N-terminal valines in Hb. The N-substituted valines can be detached, enriched and measured selectively as thiohydantoins by the use of an Edman reagent, in this case fluorescein isothiocyanate (FITC). This procedure is denoted as the “adduct FIRE procedure” as the FITC reagent is used for measurement of adducts (R) formed from electrophilic compounds with a modified Edman procedure. In this study, fluorescein thiohydantoin (FTH) analytes of N-substituted valines from acrylamide, glycidamide and ethylene oxide, as well as their corresponding hepta- and tri-deuterium-substituted analogues, were synthesized. These analytes (n = 8) were then characterized by LC–MS/MS (ESI, positive ion mode) and obtained product ions were interpreted. A considerable work with optimization of the FIRE procedure™, resulted in a procedure in which low background levels of the studied adducts could be measured from 250 μL lyzed whole blood samples (human non-smokers). The analytes were enriched and purified with solid phase extraction columns and analyzed by LC–MS/MS with LOQ down to 1 pmol adduct/g Hb. Compared to other procedures for determination of N-terminal Hb adducts, the introduction of FITC has led to a simplified procedure, where whole blood also can be used, giving new opportunities and reduced hand on time with increased sample throughput. 相似文献
4.
Jin-Hee Park Yoo-Sin Park Si-Youn Rhim Ok-Hwa Jhee Shin-Hee Kim Seok-Chul Yang Min-Ho Lee Leslie M. Shaw Ju-Seop Kang 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2009,877(1-2):59-64
A highly sensitive and rapid method for the analysis of isradipine in human plasma using liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) was developed. The procedure involves a simple liquid–liquid extraction of isradipine and amlodipine (IS, internal standard) with methyl-t-butyl ether after alkaline treatment and separation by RP-HPLC. Detection was performed by positive ion electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode, monitoring the transitions m/z 372.1 → m/z 312.2 and m/z 408.8 → m/z 237.9, for quantification of isradipine and IS, respectively. The standard calibration curves showed good linearity within the range of 10 to 5000 pg/mL (r2 ≥ 0.9998). The lower limit of quantitation (LLOQ) was 10 pg/mL. The retention times of isradipine (0.81 min) and IS (0.65 min) suggested the potential for high throughput of the proposed method. In addition, no significant metabolic compounds were found to interfere with the analysis. This method offered good precision and accuracy and was successfully applied for the pharmacokinetic and bioequivalence studies of 5 mg of sustained-release isradipine in 24 healthy Korean volunteers. 相似文献
5.
B.R. Capacio B. Dusick J.R. Smith J.H. McDonough T.-M. Shih 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(17-18):1420-1425
In recent animal studies, several novel oxime compounds that are better than 2-PAM as antidotes against selected organophosphate (OP) nerve agents have been identified. The purpose of this study was to develop and validate a liquid chromatographic–mass spectrometric (LC–MS) method for analysis of the bis-pyridinium oxime ICD-585 (1-(2-hydroxyiminomethylpyridinium)-3-(4-carbamoylpyridinium)-propane) in plasma and to establish the utility of the method in a guinea pig model. Calibration curves were prepared using ICD-585-spiked plasma at concentrations from 0.156 to 10 μg/ml. Curves were run over a 1-month time frame and a total of 13 (n = 13) were generated. The lower limit of quantification (LLOQ) was determined to be 0.216 μg/ml. Intra- and inter-day variability was assessed by studying precision and accuracy. For intra-day studies, data from the precision determinations indicated that the % CV's ranged from 4.28 to 14.98%. The % error in the accuracy assessments ranged from ?8.73 to 4.61%. For inter-day studies, precision data ranged from 3.53 to 13.20%. The % error in the accuracy assessments ranged from 0.39 to 13.77%. Room temperature, freeze–thaw and autosampler stability was also examined. For all 3 stability studies, the compound remained within ±15% of the initial analysis. Application of the method was demonstrated by analyzing samples from guinea pigs challenged with sarin (GB) or cyclosarin (GF) (1× LD50) followed with intramuscular ICD-585 (58 μM/kg, 21.8 mg/kg). At 55 min after oxime administration, mean (±SD) plasma concentrations were 15.98 (±4.88) μg/ml and 14.57 (±3.70) μg/ml in GB- and GF-exposed animals, respectively. In summary, studies have been carried out to verify the sensitivity, precision and accuracy of the assay as well as the stability of the analyte under various conditions. The method has been demonstrated to be applicable to the analysis of plasma from nerve agent-exposed guinea pigs. 相似文献
6.
Jens Martens-Lobenhoffer Christin Dautz Stefanie M. Bode-Böger 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(3-4):487-491
Cyclic guanosine monophosphate (cGMP) is an important second messenger molecule involved in gating ion channels and activating protein kinases. Here, we describe a validated LC–MS/MS method for the quantification of cGMP in human plasma, utilizing a stable isotope labeled analogue of cGMP as I.S. Plasma samples were extracted and concentrated by weak anion exchange solid phase extraction and the extracts were chromatographically separated on a porous graphitic carbon column. The analytes were detected by positive electrospray ionization and tandem mass spectrometry. The calibration function was linear in the range 1–20 nM and the intra- and inter-day precision showed relative standard deviations of better than 2 and 6%, respectively. The accuracy was always better than 4%. Plasma concentrations in healthy human subjects determined with this method were 3.92 ± 1.17 nM (n = 20). The method was, due to its isotope labeled I.S., matrix independent. 相似文献
7.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,728(1):85-95
Perillyl alcohol (POH), a metabolite of d-limonene and a component of the lavender oil, is currently in Phase I clinical trials both as a chemopreventative and chemotherapeutic agent. In vivo, POH is metabolized to less active perillic acid (PA) and cis- and trans-dihydroperillic acids [DHPA, 4-(1′-methylethenyl)-cyclohexane-1-carboxylic acid]. Previous pharmacokinetic studies using a GC–MS method detected POH metabolites but not POH itself; thus these studies lacked information on the parent drug. The present report describes a sensitive GC–MS method for the quantitation of POH and metabolites using stable-isotopically labeled internal standards. The residue obtained from CH2Cl2 extraction of a plasma sample was silylated. The products were separated on a capillary column and analyzed by an ion-trap GC–MS using NH3 chemical ionization. POH-d3 was used as the internal standard for POH while 13C-PA-d2 was used as the internal standards for the metabolites. The quantitation limits for POH, PA, cis- and trans-DPA were <10 ng/ml using 1–2 ml plasma. The assay was validated in rat and human plasma. The assay was linear from 2 to 2000 ng/ml for POH, 10 to 1000 ng/ml for PA and trans-DHPA, and 20 to 1000 ng/ml for cis-DHPA monitored. The within-run and between-run coefficients of variation were all <8%. Preliminary pharmacokinetic data from a rat following i.v. administration of POH at 23 mg/kg and from a patient receiving POH at 500 mg/m2 p.o. was also provided. Intact POH, PA, cis- and trans-DHPA were all detected in plasma in both cases. Two new major metabolites were found in human and one in the rat plasma. 相似文献
8.
Qing-Qing Wang Shen-Si Xiang Yan-Bo Jia Lun Ou Fang Chen Hai-Feng Song Qing Liang Dan Ju 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(21):1893-1898
An improved liquid chromatographic method with on-line solid phase extraction (SPE) and tandem mass spectrometric detection was optimised for quantification of the anti-HIV peptide Sifuvirtide in human plasma. The SPE sorbents, loading buffer composition and other aspects of the on-line SPE column were investigated in detail for efficiently extracting the interesting peptides and simultaneously discarding the large amount of proteins. The gradient elution program was optimised on the analysis column to decrease the matrix effect and obtain excellent selectivity. The multiple charge ion at m/z 946.4 of Sifuvirtide was quantified by a linear ion trap mass spectrometer, operating in the positive mode, and selective reaction monitoring (SRM) acquisition. Method validation results demonstrated that the linear calibration curve covered a range of 6.1–6250 ng/mL, and the correlation coefficients (r2) were above 0.992. The lower limit of detection (LLOD) with a signal-to-noise (S/N) ratio higher than 10 was 6.1 ng/mL. The accuracy ranged from −7.6 to 10.6%, and the intra- and inter-batch precisions were less than 8.7% and 5.5%, respectively. Finally, more than nine hundred of samples from a clinical trial was completely analyzed using this on-line SPE coupled HPLC–MS/MS system in one single week, due to the rapid run-time of individual sample (6.5 min). 相似文献
9.
Oskar Gonzalez Gorka Iriarte Estitxu Rico Nerea Ferreirós Miren Itxaso Maguregui Rosa Maria Alonso Rosa Maria Jiménez 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(28):2685-2692
A simple, fast and validated method is reported for the simultaneous analysis, in human plasma, of several drugs usually combined in cardiovascular therapy (atenolol, bisoprolol, hydrochlorothiazide, chlorthalidone, salicylic acid, enalapril and its active metabolite enalaprilat, valsartan and fluvastatin) using high performance liquid chromatography–tandem mass spectrometry (LC–MS/MS) with electrospray ionization (ESI), working in multiple reaction monitoring mode (MRM). Separation of analytes and internal standard (pravastatin) was performed on a Luna C18(2) (150 mm × 4.6 mm, 3 μm) column using a gradient elution mode with a run time of 15 min. The mobile phase consisted of a mixture of acetonitrile and water containing 0.01% formic acid and 10 mM ammonium formate at pH 4.1. Sample treatment consisted of a simple protein precipitation with acetonitrile, enabling a fast analysis. The method showed good linearity, precision (RSD% values between 0.7% and 12.7%) and accuracy (relative error values between 0.9% and 14.0%). Recoveries were within 68–106% range and the ion-suppression was not higher than 22% for any analyte. The method was successfully applied to plasma samples obtained from patients under combined cardiovascular treatment. 相似文献
10.
Magdalena C. Waldhier Katja Dettmer Michael A. Gruber Peter J. Oefner 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(15-16):1103-1112
GC–MS analysis of fluorinated and non-fluorinated chloroformate and anhydride derivatives of amino acid (AA) enantiomers on two different chiral columns was compared for the direct quantification of free l- and d-AAs in human serum and urine in a single analytical run. Best sensitivity was achieved with pentafluoropropionic anhydride/heptafluorobutanol derivatives separated on a Chirasil-l-Val column. However, the occurrence of racemization during derivatization precluded accurate quantification of AA enantiomers. Derivatization with methyl chloroformate/methanol and separation on an Rt-γDEXsa column did not exhibit racemization and yielded ten baseline separated racemates of proteinogenic AAs with resolution values greater than 2.4. However, protein and peptide hydrolysis occurred in serum and urine during the highly exothermal derivatization reaction under alkaline conditions. Removing serum proteins by precipitation before derivatization and performing the reaction at neutral pH enabled the determination of accurate free AA enantiomer concentrations. Accuracy of quantification was validated by an established nonchiral GC–MS method for AA analysis. Reliable quantification was achieved using stable-isotope labeled l-AAs as internal standards. Limits of detection (LOD) and lower limits of quantification (LLOQ) for the d-AAs were in the range of 3.2–446 nM and 0.031–1.95 μM, respectively. Relative standard deviations (N = 6) for the measurement of AAs in urine and serum ranged from 0.49–11.10% to 0.70–3.87%, respectively. The method was applied to the analysis of urine from 19 patients with renal insufficiency. In comparison to healthy probands, D-ratios of Ala, Val, Pro, Thr, Asp, and Asn were significantly increased. 相似文献
11.
Chang Cheng Shaorong Liu Deqing Xiao John Hollembaek Lili Yao Jing Lin Steven Hansel 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(28):2831-2838
Simple, sensitive and robust liquid chromatography–tandem mass spectrometer (LC–MS/MS) methods were developed and validated for the determination of lipopeptide polymyxins and glycopeptide vancomycin in rat plasma. The effect of trichloroacetic acid (TCA) concentration on sample recoveries (peak area of sample recovered from plasma/peak area of sample from neat solvent solutions) was studied and an optimized concentration of 30% TCA were determined that gives the best sample recovery for the peptides from rat plasma. The effect of the TCA concentration on the chromatographic behavior of peptides was studied on a Phenomenex Jupiter C18 5 μ 300 Å 50 mm × 2 mm column using a mobile phase with a pH of 2.8. Other than protein precipitation, TCA also acted as ion pairing reagent and was only present in the samples but not in the mobile phases. The data demonstrated that by increasing the TCA concentration, the analyte retention and sensitivity were improved. The absence of TCA in mobile phase helped to reduce the ion source contamination and to achieve good reproducibility. The plasma method was linearly calibrated from 5 to 5000 ng/mL for polymyxins with precisions to be of 2.3–10.8%, and accuracies to be 91.7–107.4% for polymyxin B1, B2, E1, E2, respectively. For vancomycin the calibration is from 1 to 5000 ng/mL with precisions to be of 7.8–10.3 and accuracies to be 96.2–102.0%. The LLOQs corresponding with a coefficient of variation less than 20% were 7.5, 18.1, 7.3, 5.0 and 1.0 ng/mL for polymyxin B1, B2, E1, E2 and vancomycin, respectively. 相似文献
12.
Wenying Jian Richard Edom Naidong Weng Peter Zannikos Zhiming Zhang Hao Wang 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(20):1687-1699
Endogenous ethanolamides (fatty acid amides), including arachidonyl ethanolamide (anandamide, AEA), oleoyl ethanolamide (OEA), and palmitoyl ethanolamide (PEA), are substrates of fatty acid amide hydrolase (FAAH). FAAH may play an important role for pain, anxiety/depression, and metabolic disorders. Ethanolamides are considered to be potential pharmacodynamic biomarkers to determine target engagement for FAAH inhibition by novel pharmaceutical agents. A highly selective, sensitive, and high-throughput liquid chromatography tandem mass spectrometry (LC–MS/MS) method was developed and validated for simultaneous quantitation of AEA, OEA, and PEA in human plasma. The method employed D4-AEA, D4-OEA, and 13C2-PEA as “surrogate analytes” to establish the concentration–mass response relationship, i.e. a regression equation. The concentrations of AEA, OEA, and PEA were calculated based on the regression equations derived from the surrogate analytes. This approach made it possible to prepare calibration standard and quality control (QC) samples in plasma devoid of interferences from the endogenous analytes. The analytical methodology required 150 μL of human plasma that was processed via liquid–liquid extraction (LLE) using a 96-well plate format. Chromatographic separation was achieved with a reversed-phase high performance liquid chromatography (HPLC) column using gradient elution, and the run time was 3 min. The method was fully validated and it demonstrated acceptable accuracy, precision, linearity, and specificity. The lower limit of quantitation (LLOQ) was 0.1/0.5/0.5 ng/mL for AEA/OEA/PEA, which was sensitive enough to capture the basal plasma levels in healthy subjects. Bench-top stability in plasma, freeze–thaw stability in plasma, frozen long-term stability in plasma, autosampler stability, and stock solution stability all met acceptance criteria (%Bias within ±12.0%). Characterization of stability in purchased/aged blood indicated that ethanolamides are subject to degradation mediated by intracellular membrane-bound FAAH, which has been shown to be inhibited by phenylmethylsulfonyl fluoride (PMSF). In the presence of PMSF, ethanolamide levels increased slightly over time, suggesting that blood cells release ethanolamides into plasma. Whole blood stability conducted in fresh blood immediately following collection revealed that there was significant elevation of ethanolamide concentrations (∼1.3–2.0-fold on ice and ∼1.5–3.0-fold at room temperature by 2 h), indicating that de novo synthesis and release from blood cells were the predominant factors affecting ethanolamide concentrations ex vivo. Accordingly, conditions that ensured rapid separation of plasma from blood cells and consistency in the blood harvesting procedures were established and implemented for clinical studies to minimize the ex vivo elevation of plasma ethanolamide concentrations. The variability (intra-subject and inter-subject) of plasma ethanolamide levels was evaluated in healthy subjects during a Phase 0 study (no drug administration) that simulated the design of single-ascending dose and multiple-ascending dose clinical trials in terms of sample collection time points, population, food, and activity. The data indicated there was relatively large inter- and intra-subject variation in plasma ethanolamide concentrations. In addition, apparent variations due to time of day and/or food effects were also revealed. Understanding the variability of ethanolamide levels in humans is very important for study design and data interpretation when changes in ethanolamide levels are used as target engagement biomarkers in clinical trials. 相似文献
13.
Wei-Dong Zhang Xiao-Juan Wang Si-Yuan Zhou Yi Gu Rong Wang Tao-Li Zhang Hong-Quan Gan 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(23):2137-2140
Flavanoid kaempferol is mainly present as glucuronides and sulfates in rat plasma, and small amounts of the intact aglycone are also detected. In the this study, a rapid, specific and sensitive liquid chromatography–electrospray ionization-tandem mass spectrometry method (HPLC–MS/MS) was developed and validated for determination of kaempferol and its major metabolite glucuronidated kaempferol in rat plasma. A liquid–liquid extraction with acetic ether was involved for the extraction of kaempferol and internal standard. Analytes were separated on a C18 column (150 mm × 2.1 mm, 4.5 μm, Waters Corp.) with isocratic elution at a flow-rate of 0.3 ml min−1. The mobile phase was consisted of 0.5% formic acid and acetonitrile (50:50, v/v). The Quattro Premier HPLC–MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. The method was validated according to the FDA guidelines for validation of bioanalytical method. The validated method was successfully applied to the study of the pharmacokinetics in rats after oral administration of kaempferol with different doses. 相似文献
14.
Tao Jiang Zhengxing Rong Liang Peng Bing Chen Yifan Xie Congying Chen Jing Sun Yiping Xu Yang Lu Hongzhuan Chen 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(5-6):615-619
A simple sensitive and robust method for simultaneous determination of citalopram and desmethylcitalopram was developed using liquid chromatography tandem mass spectrometry (LC–MS/MS). A 200 μL aliquot of plasma sample was employed and deproteinized with methanol and desipramine was used as the internal standard. After vortex mixing and centrifugation, the supernatant was diluted with water (1:1, v/v) and then directly injected to analysis. Analytes were separated by a Zorbax XDB C18 column with the mobile phase composed of acetonitrile and water (30:70, v/v) with 0.25% formic acid and monitored in MRM mode using a positive electrospray source with tandem mass spectrometry detection. The total run time was 3.5 min. The dynamic range was 0.2–100 ng/mL for citalopram and 0.25–50 ng/mL for desmethylcitalopram, respectively. Compared to the best existing literatures for plasma samples, the same LOQ for CIT (0.5 ng/mL) and lower LOQ for DCIT (0.25 vs 5 ng/mL) were reached, and less sample preparation steps and runtime (3.5 vs 10 min) were taken for our method. Accuracy and precision was lower than 8% and lower than 11.5% for either target. Validation results and its application to the analysis of plasma samples after oral administration of citalopram in healthy Chinese volunteers demonstrated the method was applicable to pharmacokinetic studies. 相似文献
15.
Michela Tomaiuolo Gennaro Vecchione Maurizio Margaglione Daniela Pisanelli Elvira Grandone 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2009,877(28):3292-3299
Homocysteine is an endogenous sulphydryl aminoacid irreversibly catabolized by transsulfuration to cysteine or remethylated to methionine. Increased plasma levels of homocysteine are an independent risk factor for atherosclerosis and cardiovascular disease. Accurate and reliable quantification of this amino acid in plasma samples is essential in clinical practice to explore the presence of a hyperhomocysteinemia, for instance after an ischemic event, or to control a possible adjunctive risk factor in patients at higher risk. In this review, LC–ESI-MS/MS methods are discussed and compared with other analytical methods for plasma homocysteine. LC–ESI-MS/MS is a technique combining the physicochemical separation of liquid chromatography with the analysis of mass spectrometry. It is based on stable-isotope dilution and possesses inherent accuracy and precision. Quantitative analysis is achieved by using commercially available homocystine-d8 as an internal standard. Taking advantage of the high sensitivity and specificity, approaches involving LC–ESI-MS/MS require less laborious sample preparation, no derivatization and produce reliable results. 相似文献
16.
Daniela Rago Kristensen Mette Gözde Gürdeniz Federico Marini Morten Poulsen Lars Ove Dragsted 《Metabolomics : Official journal of the Metabolomic Society》2013,9(6):1202-1215
Fruit and vegetable consumption has been associated with several health benefits; however the mechanisms are largely unknown at the biochemical level. Our research aims to investigate whether plasma metabolome profiling can reflect biological effects after feeding rats with raw apple by using an untargeted UPLC–ESI–TOF–MS based metabolomics approach in both positive and negative mode. Eighty young male rats were randomised into groups receiving daily 0, 5 or 10 g fresh apple slices, respectively, for 13 weeks. During weeks 3–6 some of the animals were receiving 4 mg/ml 1,2-dimethylhydrazine dihydrochloride (DMH) once a week. Plasma samples were taken at the end of the intervention and among all groups, about half the animals were 12 h fasted. An initial ANOVA-simultaneous component analysis with a three-factor or two-factor design was employed in order to isolate potential metabolic variations related to the consumption of fresh apples. Partial least squares-discriminant analysis was then applied in order to select discriminative features between plasma metabolites in control versus apple fed rats and partial least squares modelling to reveal possible dose response. The findings indicate that in laboratory rats apple feeding may alter the microbial amino acid fermentation, lowering toxic metabolites from amino acids metabolism and increasing metabolism into more protective products. It may also delay lipid and amino acid catabolism, gluconeogenesis, affect other features of the transition from the postprandial to the fasting state and affect steroid metabolism by suppressing the plasma level of stress corticosteroids, certain mineralocorticoids and oxidised bile acid metabolites. Several new hypotheses regarding the cause of health effects from apple intake can be generated from this study for further testing in humans. 相似文献
17.
Marianne Koller Christian Becker Horst Thiermann Franz Worek 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(17-18):1226-1233
The purpose of this study was to check the applicability of different analytical methods for the identification of unknown nerve agents in human body fluids. Plasma and urine samples were spiked with nerve agents (plasma) or with their metabolites (urine) or were left blank. Seven random samples (35% of all samples) were selected for the verification test. Plasma was worked up for unchanged nerve agents and for regenerated nerve agents after fluoride-induced reactivation of nerve agent-inhibited butyrylcholinesterase. Both extracts were analysed by GC–MS. Metabolites were extracted from plasma and urine, respectively, and were analysed by LC–MS. The urinary metabolites and two blank samples could be identified without further measurements, plasma metabolites and blanks were identified in six of seven samples. The analysis of unchanged nerve agent provided five agents/blanks and the sixth agent after further investigation. The determination of the regenerated agents also provided only five clear findings during the first screening because of a rather noisy baseline. Therefore, the sample preparation was extended by a size exclusion step performed before addition of fluoride which visibly reduced baseline noise and thus improved identification of the two missing agents. The test clearly showed that verification should be performed by analysing more than one biomarker to ensure identification of the agent(s). 相似文献
18.
Hari Kosanam Fei Ma Hui He Suma Ramagiri Veeresa Gududuru Gabor J. Tigyi Koen Van Rompay Duane D. Miller Charles R. Yates 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(26):2379-2383
Octadecenyl thiophosphate (OTP), a synthetic analogue of the lysophospholipid growth factor lysophosphatidic acid (LPA), significantly reduces mortality following a lethal dose of LD80/30 radiation exposure in a mouse model of whole-body irradiation. To facilitate dose scaling between species, we developed a novel liquid chromatography/tandem mass spectrometry (LC–MS/MS) for the preclinical pharmacokinetic characterization of OTP in monkeys. Sample extraction was carried out using a butanol based liquid–liquid extraction method. A partially deuterated OTP analogue was used as internal standard (IS). OTP and IS were separated by reversed-phase liquid chromatography on a C-8 column using 10 mM ammonium acetate and acetonitrile. A triple quadrupole mass spectrometer operating in the negative electrospray ionization mode with multiple reaction monitoring was used to detect OTP and IS transitions of m/z 363.1 → 95.0 and 403.1 → 95.0. The method was applied to determine pharmacokinetic parameters in monkeys receiving a single oral OTP dose (3 mg/kg). OTP is readily absorbed with a relatively long half-life which supports further preclinical testing of OTP as a radioprotectant in monkeys. 相似文献
19.
Stable deuterium internal standard for the isotope-dilution LC–MS/MS analysis of elastin degradation
Shuren Ma Gerard M. Turino Takahiro Hayashi Hiroto Yanuma Toyonobu Usuki Yong Y. Lin 《Analytical biochemistry》2013,440(2):158-165
Chemical synthesis of the deuterium isotope desmosine-d4 has been achieved. This isotopic compound possesses all four deuterium atoms at the alkanyl carbons of the alkyl amino acid substitution in the desmosine molecule and is stable toward acid hydrolysis; this is required in the measurement of two crosslinking molecules, desmosine and isodesmosine, as biomarkers of elastic tissue degradation. The degradation of elastin occurs in several widely prevalent diseases. The synthesized desmosine-d4 is used as the internal standard to develop an accurate and sensitive isotope-dilution liquid chromatography–tandem mass spectrometry analysis, which can serve as a generalized method for an accurate analysis of desmosine and isodesmosine as biomarkers in many types of biological tissues involving elastin degradation. 相似文献
20.
Dan Zhang Yingwu Wang Jiangbin Han Weisong Yu Lili Deng J. Paul Fawcett Zeyuan Liu Jingkai Gu 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2009,877(5-6):581-585
This paper describes a rapid and sensitive method for the quantitation of 20(S)-protopanaxadiol (PPD) in human plasma based on high-performance liquid chromatography–tandem mass spectrometry (LC–MS/MS). The analyte and internal standard (I.S.), ginsenoside Rh2, were extracted from plasma by liquid–liquid extraction and separated on a Zorbax extend C18 analytical column using methanol–acetonitrile-10 mM ammonium acetate (47.5:47.5:5, v/v/v) as mobile phase. Detection was by tandem mass spectrometry using electrospray ionization in the positive ion mode and multiple reaction monitoring (MRM). The assay was linear over the concentration range 0.1–100.0 ng/ml with a limit of detection of 0.05 ng/ml. The method was successfully applied to a clinical pharmacokinetic study in healthy volunteers after a single oral administration of a PPD 25 mg capsule. 相似文献