共查询到20条相似文献,搜索用时 0 毫秒
1.
Hong-gang Lou Hong Yuan Zou-rong Ruan Bo Jiang 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(7-8):682-688
For the first time, a highly sensitive and simple LC–MS/MS method after one-step precipitation was developed and validated for the simultaneous determination of paracetamol (PA), pseudoephedrine (PE), dextrophan (DT) and chlorpheniramine (CP) in human plasma using diphenhydramine as internal standard (IS). The analytes and IS were separated on a YMC-ODS-AQ C18 Column (100 mm × 2.0 mm, 3 μm) by a gradient program with mobile phase consisting of 0.3% (v/v) acetic acid and methanol at a flow rate of 0.30 mL/min. Detection was performed on a triple quadrupole tandem mass spectrometer via electrospray ionization in the positive ion mode. The method was validated and linear over the concentration range of 10–5000 ng/mL for PA, 2–1000 ng/mL for PE, 0.05–25 ng/mL for DT and 0.1–50 ng/mL for CP. The accuracies as determined from quality control samples were in range of ?8.37% to 3.13% for all analytes. Intra-day and inter-day precision for all analytes were less than 11.54% and 14.35%, respectively. This validated method was successfully applied to a randomized, two-period cross-over bioequivalence study in 20 healthy Chinese volunteers receiving multicomponent formulations containing 325 mg of paracetamol, 30 mg of pseudoephedrine hydrochloride, 15 mg of dextromethorphan hydrobromide and 2 mg of chlorphenamine maleate. 相似文献
2.
Femke de Velde Jan-Willem C. Alffenaar A. Mireille A. Wessels Ben Greijdanus Donald R.A. Uges 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2009,877(18-19):1771-1777
The drug combination rifampicin and clarithromycin is used in regimens for infections caused by Mycobacteria. Rifampicin is a CYP3A4 inducer while clarithromycin is known to inhibit CYP3A4. During combined therapy rifampicin concentrations may increase and clarithromycin concentrations may decrease. Therefore a simple, rapid and easy method for the measurement of the blood concentrations of these drugs and their main metabolites (14-hydroxyclarithromycin and 25-desacetylrifampicin) is developed to evaluate the effect of the drug interaction. The method is based on the precipitation of proteins in human serum with precipitation reagent containing the internal standard (cyanoimipramine) and subsequently high-performance liquid chromatography (HPLC) analysis and tandem mass spectrometry (MS/MS) detection in an electron positive mode. The method validation included selectivity, linearity, accuracy, precision, dilution integrity, recovery and stability according to the “Guidance for Industry – Bioanalytical Method Validation” of the FDA. The calibration curves were linear in the range of 0.10–10.0 mg/L for clarithromycin and 14-hydroxyclarithromycin and 0.20–5.0 mg/L for rifampicin and 25-desacetylrifampicin, with within-run and between-run precisions (CVs) in the range of 0% to ?10%. The components in human plasma are stable after freeze–thaw (three cycles), in the autosampler (3 days), in the refrigerator (3 days) and at room temperature (clarithromycin and 14-hydroxyclarithromycin: 3 days; rifampicin and 25-desacetylrifampicin: 1 day). The developed rapid and fully validated liquid chromatography–tandem mass spectrometry (LC/MS/MS) method is suitable for the determination of clarithromycin, 14-hydroxyclarithromycin, rifampicin and 25-desacetylrifampicin in human plasma. 相似文献
3.
Dezhi Kong Sanni Li Xiaowei Zhang Jianmin Gu Man Liu Yan Meng Yan Fu Xiaojin La Gangqiang Xue Lantong Zhang Qiao Wang 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(29):2989-2996
A simple, sensitive and selective liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the simultaneous determination of m-nisoldipine and its three metabolites in rat plasma has been developed using nitrendipine as an internal standard (IS). Following liquid–liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse phase C18 column and analyzed by MS in the multiple reaction monitoring (MRM) mode. To avoid contamination by residual sample in the injection syringe, a special injection protocol was developed. We found that m-nisoldipine, metabolite M1 and IS could be ionized under positive or negative electrospray ionization conditions, whereas metabolite M and M2 could only be ionized in the positive mode. The mass spectrometry fragmentation pathways for these analytes are analyzed and discussed herein. The total analysis time required less than 5 min per sample. We employed this method successfully to study the metabolism of m-nisoldipine when it was orally administered to rats at a dose of 9 mg/kg. Three metabolites of m-nisoldipine and an unknown compound of molecular weight 386 were found for the first time in rat plasma. The concentration of the potentially active metabolite was approximately equal to its parent compound concentration. 相似文献
4.
Bo Jiang Zourong Ruan Honggang Lou Hong Yuan 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(7-8):719-723
A rapid, specific and sensitive liquid chromatography–electrospray ionization-tandem mass spectrometry method was developed and validated for determination of cymipristone in human plasma. Mifepristone was used as the internal standard (IS). Plasma samples were deproteinized using methanol. The compounds were separated on a ZORBAX SB C18 column (50 mm × 2.1 mm i.d., dp 1.8 μm) with gradient elution at a flow-rate of 0.3 ml/min. The mobile phase consisted of 10 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadruple tandem mass spectrometer by selective reaction monitoring (SRM) mode via electrospray ionization. Target ions were monitored at [M+H]+ m/z 498 → 416 and 430 → 372 in positive electrospray ionization (ESI) mode for cymipristone and IS, respectively. Linearity was established for the range of concentrations 0.5–100 ng/ml with a coefficient correlation (r) of 0.9996. The lower limit of quantification (LLOQ) was identifiable and reproducible at 0.5 ng/ml. The validated method was successfully applied to study the pharmacokinetics of cymipristone in healthy Chinese female subjects. 相似文献
5.
Wenqi Cui Xiaoyan Chen Yan Zhan Zhenzhong Zhang Yifan Zhang Dafang Zhong 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(15-16):1181-1184
A rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the determination of picamilon concentration in human plasma. Picamilon was extracted from human plasma by protein precipitation. High performance liquid chromatography separation was performed on a Venusil ASB C18 column with a mobile phase consisting of methanol ?10 mM ammonium acetate–formic acid (55:45:01, v/v/v) at a flow rate of 0.65 ml/min. Acquisition of mass spectrometric data was performed in selected reaction monitoring mode, using the transitions of m/z 209.0 → m/z (78.0 + 106.0) for picamilon and m/z 152.0 → m/z (93.0 + 110.0) for paracetamol (internal standard). The method was linear in the concentration range of 1.00–5000 ng/ml for the analyte. The lower limit of quantification was 1.00 ng/ml. The intra- and inter-assay precision were below 13.5%, and the accuracy was between 99.6% and 101.6%. The method was successfully applied to characterize the pharmacokinetic profiles of picamilon in healthy volunteers. This validated LC–MS/MS method was selective and rapid, and is suitable for the pharmacokinetic study of picamilon in humans. 相似文献
6.
Ke Liu Dafang ZhongXiaoyan Chen 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(26):2415-2420
An enantioselective and sensitive method was developed and validated for determination of doxazosin enantiomers in human plasma by liquid chromatography–tandem mass spectrometry. The enantiomers of doxazosin were extracted from plasma using ethyl ether/dichloromethane (3/2, v/v) under alkaline conditions. Baseline chiral separation was obtained within 9 min on an ovomucoid column using an isocratic mobile phase of methanol/5 mM ammonium acetate/formic acid (20/80/0.016, v/v/v) at a flow rate of 0.60 mL/min. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, using the transitions of m/z 452 → 344 for doxazosin enantiomers, and m/z 384 → 247 for prazosin (internal standard). The method was linear in the concentration range of 0.100–50.0 ng/mL for each enantiomer using 200 μL of plasma. The lower limit of quantification (LLOQ) for each enantiomer was 0.100 ng/mL. The intra- and inter-assay precision was 5.0–11.1% and 5.7–7.6% for R-(−)-doxazosin and S-(+)-doxazosin, respectively. The accuracy was 97.4–99.5% for R-(−)-doxazosin and 96.8–102.8% for S-(+)-doxazosin. No chiral inversion was observed during the plasma storage, preparation and analysis. The method proved adequate for enantioselective pharmacokinetic studies of doxazosin after oral administration of therapeutic doses of racemic doxazosin. 相似文献
7.
Ping-Fei Fang Hua-Lin Cai Huan-De Li Rong-Hua Zhu Qin-You Tan Wei Gao Ping Xu Yi-Ping Liu Wen-Yuan Zhang Yong-Chang Chen Feng Zhang 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(24):2286-2291
A rapid and selective high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method for simultaneous determination of isoniazid (INH), rifampicin (RFP) and levofloxacin (LVX) in mouse tissues and plasma has been developed and validated, using gatifloxacin as the internal standard (I.S.). The compounds and I.S. were extracted from tissue homogenate and plasma by a protein precipitation procedure with methanol. The HPLC separation of the analytes was performed on a Welch materials C4 column (250 mm × 4.6 mm, 5.0 μm, USA) at 25 °C, using a gradient elution program with the initial mobile phase constituting of 0.05% formic acid and methanol (93:7, v/v) at a flow-rate of 1.0 ml/min. For all the three analytes, the recoveries varied between 83.3% and 98.8% in tissues and between 75.5% and 90.8% in plasma, the accuracies ranged from 91.7% to 112.0% in tissues and from 94.6% to 108.8% in plasma, and the intra- and inter-day precisions were less than 13.3% in tissues and less than 8.2% in plsama. Calibration ranges for INH were 0.11–5.42 μg/g in tissues and 0.18–9.04 μg/ml in plasma, for RFP were 0.12–1200 μg/g in tissues and 4.0–200 μg/ml in plasma, and for LVX were 0.13–26.2 μg/g in tissues and 0.09–4.53 μg/ml in plasma. The lower limits of quantification (LLOQs) for INH, RFP and LVX in mouse tissues were 0.11, 0.12 and 0.13 μg/g and for those in mouse plasma were 18.1, 20.0 and 21.8 ng/ml, respectively. The limits of detection (LODs) for INH, RFP and LVX in mouse tissues were 0.04, 0.05 and 0.05 μg/g and for those in mouse plasma were 5.5, 6.0 and 6.6 ng/ml, respectively. The established method was successfully applied to simultaneous determination of isoniazid, rifampicin and levofloxacin in mouse plasma and different mouse tissues. 相似文献
8.
Wei Yang Chao Feng Dezhi Kong Xiaowei Shi Yang Cui Man Liu Qiao Wang Yongli Wang Lantong Zhang 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(5-6):575-582
A sensitive, specific and rapid liquid chromatography–mass spectrometry (LC–MS) method has been developed and validated for the simultaneous determination of xanthotoxin (8-methoxypsoralen), psoralen, isoimpinellin (5,8-dimethoxypsoralen) and bergapten (5-methoxypsoralen) in rat plasma using pimpinellin as an internal standard (IS). The plasma samples were pretreated by protein precipitation with methanol and chromatographic separation was performed on a C18 column with a mobile phase composed of 1 mmol ammonium acetate and methanol (30:70, v/v). The detection was accomplished by multiple-reaction monitoring (MRM) scanning via electrospray ionization (ESI) source operating in the positive ionization mode. The optimized mass transition ion-pairs (m/z) for quantitation were 217.1/202.1 for xanthotoxin, 187.1/131.1 for psoralen, 247.1/217.0 for isoimpinellin, 217.1/202.1 for bergapten, and 247.1/231.1 for IS. The total run time was 6 min between injections. The calibration curves were linear over the investigated concentration range with all correlation coefficients higher than 0.998. The lower limits of quantitation (LLOQ) of these analytes were less than 1.21 ng/ml. The intra- and inter-day RSD were no more than 9.7% and the relative errors were within the range of ?8.1% to 4.5%. The average extraction recoveries for all compounds were between 90.7% and 106.2%. The proposed method was further applied to the determination of actual plasma samples from rats after oral administration of Radix Glehniae extract. 相似文献
9.
Wuyi Zha Zhimeng Zhu 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(9-10):831-835
A simple and reproducible high performance liquid chromatography–tandem mass spectrometric method was developed for methocarbamol analysis in human plasma. Methocarbamol and the internal standard (IS) were extracted by a protein precipitation method. Under isocratic separation condition the chromatographic run time was 3.0 min. The calibration curve was linear over a range of 150–12,000 ng/mL with good intraday assay and interday assay precision (CV% < 10.9%). The method was proven to be sensitive and selective for the analysis of methocarbamol in human plasma for bioequivalence study. 相似文献
10.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,752(1):9-16
A liquid chromatographic–mass spectrometric (LC–MS) assay was developed and validated for the determination of itraconazole (ITZ) in rat heparinized plasma using reversed-phase HPLC combined with positive atmospheric pressure ionization (API) mass spectrometry. After protein precipitation of plasma samples (0.1 ml) with acetonitrile containing nefazodone as an internal standard (I.S.), a 50-μl aliquot of the supernatant was mixed with 100 μl of 10 mM ammonium formate (pH 4.0). An aliquot of 25 μl of the mixture was injected onto a BDS Hypersil C18 column (50×2 mm; 3 μm) at a flow-rate of 0.3 ml/min. The mobile phase comprising of 10 mM ammonium formate (pH 4) and acetonitrile (60:40, v/v) was used in an isocratic condition, and ITZ was detected in single ion monitoring (SIM) mode. Standard curves were linear (r2≥0.994) over the concentration range of 4–1000 ng/ml. The mean predicted concentrations of the quality control (QC) samples deviated by less than 10% from the corresponding nominal values; the intra-assay and inter-assay precision of the assay were within 8% relative standard deviation. Both ITZ and I.S. were stable in the injection solvent at room temperature for at least 24 h. The extraction recovery of ITZ was 96%. The validated assay was applied to a pharmacokinetic study of ITZ in rats following administration of a single dose of itraconazole (15 mg/kg). 相似文献
11.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,734(1):145-153
A sensitive and specific assay of imidapril and its active metabolite, imidaprilat, in human plasma has been developed. This method is based on rapid isolation and high-performance liquid chromatography (HPLC)–electrospray ionization (ESI)-tandem mass spectrometry (MS–MS). Imidapril and imidaprilat were isolated from human plasma using OASIS HLB (solid-phase extraction cartridge), after deproteinization. The eluent from the cartridge was evaporated to dryness, and the residue was reconstituted in mobile phase and injected into the HPLC–ESI-MS–MS system. Each compound was separated on a semi-micro ODS column in acetonitrile–0.05% (v/v) formic acid (1:3, v/v). The selected ion monitoring using precursor→product ion combinations of m/z 406→234 and 378→206, was used for determination of imidapril and imidaprilat, respectively. The linearity was confirmed in the concentration range of 0.2 to 50 ng/ml in human plasma, and the precision of this assay, expressed as a relative standard deviation, was less than 13.2% over the entire concentration range with adequate assay accuracy. The HPLC–ESI-MS–MS method correlates well with the radioimmunoassay method, therefore, it is useful for the determination of imidapril and imidaprilat with sufficient sensitivity and specificity in clinical studies. 相似文献
12.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,757(1):69-78
We developed a sensitive and specific liquid chromatography–electrospray mass spectrometric (HPLC–ESI-MS) assay for the simultaneous determination of reduced and oxidized glutathione (GSH and GSSG) in peripheral blood mononuclear cells (PBMC). Following derivatization with N-ethylmaleimide to prevent GSH auto-oxidation, addition of thiosalicylic acid as internal standard, and protein precipitation with cold acetonitrile, the samples were injected into a diol column, eluted with acetonitrile–1% aqueous acetic acid (25:75) and detected by the ESI-MS system. The optimized method exhibited a good detection limit for both analytes (0.01 and 0.05 μM for GSH and GSSG, respectively). Good linearity was reached in the 0.01–20 μM range for GSH and 0.05–20 μM for GSSG. The mean recoveries of GSH and GSSG were 98.5–100.6% and 105.8–111.5%, respectively. The run-to-run repeatability for retention time and peak area was RSD% 0.06 and 1.75 for GSH and 0.18 and 2.50 for GSSG. The optimized method was applied to GSH and GSSG assay in PBMC analyzing 20 healthy individuals. 相似文献
13.
Vivekanandan Kannan Deepak Gadamsetty Madhankumar Rose Stella Maria Imran Mustafa Anand Khedkar Nitesh Dave Muruganandam Arumugam Harish Iyer 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(15-16):1069-1076
A kinetic study of atosiban was conducted following repeated intravenous administration in Wistar rats. Sample analysis was performed using liquid chromatography–tandem mass spectrometry (LC–MS/MS) following full validation of an in-house method. Eptifibatide, a cyclic peptide, was used as an internal standard (IS). The analyte and internal standard were extracted using solid phase extraction (SPE) method. Chromatographic separation was carried out using an ACE C18 5 μm 50 mm × 4.6 mm column with gradient elution. Mass spectrometric detection was performed using TSQ Quantum ultra AM. The lower limit of quantification was 0.01 μg/ml when 100 μl rat plasma was used. Plasma concentrations of atosiban were measured at 0 (pre-dose), 2, 15, 30, 45, 60, 120 min at the dosage levels of 0.125 mg/kg (low dose), 0.250 mg/kg (mid dose), and 0.500 mg/kg (high dose), respectively. Atosiban plasma concentration measured at Day 1 showed mean peak atosiban concentration (Cmax) 0.40, 0.57, 1.95 μg/ml for low, mid and high dose treated animals and mean peak concentration on Day 28 was 0.41, 0.88, 1.31 μg/ml on Day 28 for low, mid and high dose treated animals. 相似文献
14.
Ohmori T Suzuki A Niwa T Ushikoshi H Shirai K Yoshida S Ogura S Itoh Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(15-16):1038-1042
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for the simultaneous determination of eight β-lactam antibiotics, including ampicillin, cefazolin, cefepime, cefmetazole, cefotaxime, doripenem, meropenem, and piperacillin, in human serum. Sample specimens were subjected to solid phase extraction (SPE) using Waters Oasis® HLB cartridges (30 mg). Chromatographic separation was performed with a high-resolution octadecyl silica column compatible with hydrophilic compounds, using a gradient of 10 mM aqueous ammonium formate containing 0.1% formic acid-methanol. Antibiotics were detected by a triple quadrupole mass spectrometer (MS/MS) with electrospray ionization and quantified by the multiple reaction monitoring mode. A total run time of 13 min was applied. Linearity in the calibration was obtained over a range of 0.1–50 μg/mL of the β-lactam antibiotics, except for doripenem. The lower limit of quantification was 0.005–0.5 μg/mL, using 50 μL serum. The recovery rate exceeded 80.2% for these analytes, except for doripenem (49.1%) and meropenem (62.3%). The present method is applicable to routine therapeutic monitoring of β-lactam antibiotics in clinical practice. 相似文献
15.
Xiaoqiang Xiang Yi HanMikko Neuvonen Jouko LaitilaPertti J. Neuvonen Mikko Niemi 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(1):51-60
We report a sensitive and robust method to determine cholic acid (CA), chenodeoxycholic acid (CDCA), deoxycholic acid (DCA), lithocholic acid (LCA), ursodeoxycholic acid (UDCA), and their taurine- and glycine-conjugate concentrations in human plasma using liquid chromatography–tandem mass spectrometry. Activated charcoal was utilized to prepare bile acid-free plasma, which served as the biological matrix for the preparation of standard and quality control samples. Plasma sample preparation involved solid-phase extraction. A total of 16 bile acids and 5 internal standards were separated on a reverse column by gradient elution and detected by tandem mass spectrometry in negative ion mode. The calibration curve was linear for all the bile acids over a range of 0.005–5 μmol/L. The extraction recoveries for all the analytes fell in the range of 88–101%. Intra-day and inter-day coefficients of variation were all below 10%. A stability test showed that all the bile acids were stable in plasma for at least 6 h at room temperature, at least three freeze–thaw cycles, in the −70 °C or −20 °C freezer for 2 months, and also in the reconstitution solution at 8 °C for 48 h. Comparison of the matrix effect of bile acid-free plasma with that of real plasma indicated that the charcoal purification procedure did not affect the properties of charcoal-purified plasma as calibration matrix. This method has been used to determine the bile acid concentrations in more than 300 plasma samples from healthy individuals. In conclusion, this method is suitable for the simultaneous quantification of individual bile acids in human plasma. 相似文献
16.
Lukáš Chytil Martin Štícha Olga Matoušková František Perlík Ondřej Slanař 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2009,877(20-21):1937-1942
A GC–MS assay for stereoselective determination of tramadol and its pharmacologically active phase I metabolite O-desmethyltramadol in human urine was developed. Nefopam was used as internal standard. The method involves a simple solid phase extraction with chiral analysis by gas chromatography–electron ionization mass spectrometry using m/z 263; 58, 249; 58, and 179; 58 for the determination of concentration of tramadol, O-desmethyltramadol and internal standard, respectively. Chromatography was performed on a Rt-βDEXcst column containing alkylated beta-cyclodextrins as a chiral selector. The calibration curves were linear in the concentration range 0.1–20 μg/mL (R2 ≥ 0.998). Intra-day accuracies ranged between 97.2–104.9%, 96.1–103.2%, and 97.3–102.8% at the lower, intermediate, and high concentration for all analytes, respectively. Inter-day accuracies ranged between 95.2–105.7%, 99.1–105.2%, and 96.5–101.2% at the lower, intermediate, and high concentration for all analytes, respectively. This method was successfully used to determine the concentration of enantiomers of T and ODT in a pharmacogenetic study. 相似文献
17.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,692(1):7-14
Liquid chromatography–thermospray mass spectrometry (LC–TSP-MS) using isotope dilution was investigated for quantitative analysis of cortisol, cortisone, prednisolone and prednisone in human plasma. Complete separation attained by a LiChroCART Supersupher reversed-phase column and elution with 0.05 M ammonium formate–tetrahydrofuran–methanol (180:53:17, v/v/v) resulted in a significantly large isotope effect of the deuterium-labeled analogs on the HPLC behavior and caused difficulty in quantification. Reduction of the isotope effect on the retention times using 0.05 M ammonium formate–acetonitrile (65:35, v/v) permitted accurate quantification of cortisol and cortisone by the isotope dilution LC–TSP-MS, although separation between cortisol and prednisone was incomplete. 相似文献
18.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,718(1):95-102
A confirmation procedure is described for residues of spectinomycin in bovine milk. Spectinomycin is extracted from raw milk using ion-pair reversed-phase solid-phase extraction. The extracts are ion-pair chromatographed on a polymeric reversed-phase column and analyzed on a quadrupole ion trap mass spectrometer equipped with an electrospray interface. MS–MS data are acquired in the scan mode of product ions deriving from m/z 333, the protonated molecular ion. The estimated limit of confirmation is between 0.05 and 0.1 μg/ml. The procedure was validated with control milk, fortified milk (0.1–5.0 μg/ml), and milk from cows dosed with spectinomycin. 相似文献
19.
Feng Qin Ning Li Ting Qin Yi Zhang Famei Li 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(7-8):689-694
A rapid, selective and sensitive ultra performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) method was developed to simultaneously determine venlafaxine (VEN) and O-desmethylvenlafaxine (ODV) in human plasma. Sample pretreatment involved a one-step extraction with diethyl ether of 0.5 mL plasma. The separation was carried out on an ACQUITY UPLC? BEH C18 column with 10 mmol/L ammonium acetate and methanol as the mobile phase at a flow rate of 0.30 mL/min. The detection was performed on a triple–quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. The linear calibration curves for VEN and ODV were both obtained in the concentration range of 0.200–200 ng/mL (r2 ≥ 0.99) with the lower limit of quantification (LLOQ) of 0.200 ng/mL. The intra- and inter-day precision (relative standard deviation, R.S.D.) values were less than 13% and the accuracy (relative error, R.E.) was within ±5.3% and ±3.6% for VEN and ODV. The method herein described was superior to previous methods in sensitivity and sample throughput and successfully applied to clinical pharmacokinetic study of venlafaxine sustained-release capsule in healthy male volunteers after oral administration. 相似文献
20.
Qian Zhao Xin ZhengJi Jiang Hui ZhouPei Hu 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(24):2266-2273
Here we report a method capable of quantifying ginsenoside Rg3 in human plasma and urine. The method was validated over linear range of 2.5–1000.0 ng mL−1 for plasma and 2.0–20.0 ng mL−1 for urine using ginsenoside Rg1 as I.S. Compounds were extracted with ethyl acetate and analyzed by HPLC/MS/MS (API-4000 system equipped with ESI− interface and a C18 column). The inter- and intra-day precision and accuracy of QC samples were ≤8.5% relative error and were ≤14.4% relative standard deviation for plasma; were ≤5.6% and ≤13.3% for urine. The Rg3 was stable after 24 h at room temperature, 3 freeze/thaw cycles and 131 days at −30 °C. This method has been applied to pharmacokinetic study of ginsenoside Rg3 in human. 相似文献