首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Preparative (solution) isoelectric focusing (sIEF) is a proven technique for proteome prefractionation, but carries limitations which include the risk of protein loss from isoelectric precipitation, poor focusing, and excessively long separation times. This report describes a simple yet effective method to achieve rapid focusing (as fast as 1 h) and maximize protein recovery using a carrier ampholyte sIEF system. Cathodic drift was not present over the time course of the experiment using our eight-chamber device, and we demonstrate the effectiveness of this device for focusing proteome mixtures. We also discuss an MS-compatible acidic wash protocol, which is shown to enhance the recovery of proteins following sIEF, thus, improving detection by LC-MS/MS. These approaches overcome significant shortcomings of the technique, enabling effective prefractionation prior to MS analysis.  相似文献   

2.
Due to the complexity of proteomes, developing methods of sample fractionation, separation, concentration, and detection have become urgent to the identification of large numbers of proteins, as well as the acquisition of those proteins in low abundance. In this work, liquid isoelectric focusing (LIEF) combined with 2D-LC-MS/MS was applied to the proteome of Saccharomyces cerevisiae. This yielded a total of 1795 proteins that were detected and identified by 30 fractions of protein prefractionation. Categorization of these hits demonstrated the ability of this technology to detect and identify proteins rarely seen in proteome analysis without protein fractionation. LIEF-2D-LC-MS/MS also produced improved resolution of low-abundance proteins. Furthermore, we analyzed the characteristics of proteins obtained by LIEF-2D-LC-MS/MS. 1103 proteins with CAI under 0.2 were identified, allowing us to specifically obtain detailed biochemical information on these kind proteins. It was observed that LIEF-2D-LC-MS/MS is useful for large-scale proteome analysis and may be specifically applied to systems with wide dynamic ranges.  相似文献   

3.
The high hemeozoin (beta-hemeatin) content of Plasmodium falciparum lysates imposes severe limitations on the analysis of the malarial proteome, in particular compromising the loading capacities of two-dimensional gels. Here we report on the adaptation of a recently developed solution-phase isoelectric focusing-based fractionation technique as a prefractionation strategy for efficient containment of hemeoglobin-derived products and complexity reduction, to facilitate the high-resolution gel-based quantitative analysis of plasmodial lysates.  相似文献   

4.
MS/MS is the technology of choice for analyzing complex protein mixtures. However, due to the intrinsic complexity and dynamic range present in higher eukaryotic proteomes, prefractionation is an important step to maximize the number of proteins identified. Off‐gel IEF (OG‐IEF) and high pH RP (Hp‐RP) column chromatography have both been successfully utilized as a first‐dimension peptide separation technique in shotgun proteomic experiments. Here, a direct comparison of the two methodologies was performed on ex vivo peripheral blood mononuclear cell lysate. In 12‐fraction replicate analysis, Hp‐RP resulted in more peptides and proteins identified than OG‐IEF fractionation. Distributions of peptide pIs and hydropathy did not reveal any appreciable bias in either technique. Resolution, defined here as the ability to limit a specific peptide to one particular fraction, was significantly better for Hp‐RP. This leads to a more uniform distribution of total and unique peptides for Hp‐RP across all fractions collected. These results suggest that fractionation by Hp‐RP over OG‐IEF is the better choice for typical complex proteome analysis.  相似文献   

5.
Barnea E  Sorkin R  Ziv T  Beer I  Admon A 《Proteomics》2005,5(13):3367-3375
Prefractionations of proteins prior to their proteolysis, chromatography, and MS/MS analyses help reduce complexity and increase the yield of protein identifications. A number of methods were evaluated here for prefractionating serum samples distributed to the participating laboratories as part of the human Plasma Proteome Project. These methods include strong cation exchange (SCX) chromatography, slicing of SDS-PAGE gel bands, and liquid-phase IEF of the proteins. The fractionated proteins were trypsinized and the resulting peptides were resolved and analyzed by multidimensional protein identification technology coupled to IT MS/MS. The MS/MS spectra were clustered, combined, and searched against the IPI protein databank using Pep-Miner. The identification results were evaluated for the efficacy of the different prefractionation methodologies to identify larger numbers of proteins at higher confidence and to achieve the best coverage of the proteins with the identified peptides. Prefractionation based on SCX resulted in the largest number of identified proteins, followed by gel slices and then the liquid-phase IEF. An important observation was that each of the methods revealed a set of unique proteins, some identified with high confidence. Therefore, for comprehensive identification of the serum proteins, several different prefractionation approaches should be used in parallel.  相似文献   

6.
Shotgun proteome analysis platforms based on multidimensional liquid chromatography-tandem mass spectrometry (LC-MS/MS) provide a powerful means to discover biomarker candidates in tissue specimens. Analysis platforms must balance sensitivity for peptide detection, reproducibility of detected peptide inventories and analytical throughput for protein amounts commonly present in tissue biospecimens (< 100 microg), such that platform stability is sufficient to detect modest changes in complex proteomes. We compared shotgun proteomics platforms by analyzing tryptic digests of whole cell and tissue proteomes using strong cation exchange (SCX) and isoelectric focusing (IEF) separations of peptides prior to LC-MS/MS analysis on a LTQ-Orbitrap hybrid instrument. IEF separations provided superior reproducibility and resolution for peptide fractionation from samples corresponding to both large (100 microg) and small (10 microg) protein inputs. SCX generated more peptide and protein identifications than did IEF with small (10 microg) samples, whereas the two platforms yielded similar numbers of identifications with large (100 microg) samples. In nine replicate analyses of tryptic peptides from 50 microg colon adenocarcinoma protein, overlap in protein detection by the two platforms was 77% of all proteins detected by both methods combined. IEF more quickly approached maximal detection, with 90% of IEF-detectable medium abundance proteins (those detected with a total of 3-4 peptides) detected within three replicate analyses. In contrast, the SCX platform required six replicates to detect 90% of SCX-detectable medium abundance proteins. High reproducibility and efficient resolution of IEF peptide separations make the IEF platform superior to the SCX platform for biomarker discovery via shotgun proteomic analyses of tissue specimens.  相似文献   

7.
Saliva is a readily available body fluid with great diagnostic potential. The foundation for saliva-based diagnostics, however, is the development of a complete catalog of secreted and "leaked" proteins detectable in saliva. By employing a capillary isoelectric focusing-based multidimensional separation platform coupled with electrospray ionization tandem mass spectrometry (MS), a total of 5338 distinct peptides were sequenced, leading to the identification of 1381 distinct proteins. A search of bacterial protein sequences also identified many peptides unique to several organisms and unique to the NCBI nonredundant database. To the best of our knowledge, this proteome study represents the largest catalog of proteins measured from a single saliva sample to date. Data analysis was performed on individual MS/MS spectra using the highly specific peptide identification algorithm, OMSSA. Searches were conducted against a decoyed SwissProt human database to control the false-positive rate at 1%. Furthermore, the well-curated SwissProt sequences represent perhaps the least redundant human protein sequence database (12,484 records versus the 50,009 records found in the International Protein Index human database), therefore minimizing multiple protein inferences from single peptides. This combined bioanalytical and bioinformatic approach has established a solid foundation for building up the human salivary proteome for the realization of the diagnostic potential of saliva.  相似文献   

8.
In the analysis of proteins in complex samples, pre-fractionation is imperative to obtain the necessary depth in the number of reliable protein identifications by mass spectrometry. Here we explore isoelectric focusing of peptides (peptide IEF) as an effective fractionation step that at the same time provides the added possibility to eliminate spurious peptide identifications by filtering for pI. Peptide IEF in IPG strips is fast and sharply confines peptides to their pI. We have evaluated systematically the contribution of pI filtering and accurate mass measurements on the total number of protein identifications in a complex protein mixture (Drosophila nuclear extract). At the same time, by varying Mascot identification cutoff scores, we have monitored the false positive rate among these identifications by searching reverse protein databases. From mass spectrometric analyses at low mass accuracy using an LTQ ion trap, false positive rates can be minimized by filtering of peptides not focusing at their expected pI. Analyses using an LTQ-FT mass spectrometer delivers low false positive rates by itself due to the high mass accuracy. In a direct comparison of peptide IEF with SDS-PAGE as a pre-fractionation step, IEF delivered 25% and 43% more proteins when identified using FT-MS and LTQ-MS, respectively. Cumulatively, 2190 non redundant proteins were identified in the Drosophila nuclear extract at a false positive rate of 0.5%. Of these, 1751 proteins (80%) were identified after peptide IEF and FT-MS alone. Overall, we show that peptide IEF allows to increase the confidence level of protein identifications, and is more sensitive than SDS-PAGE.  相似文献   

9.
Capillary isoelectric focusing (CIEF) involves the use of the entire capillary filled with a mixture containing protein/peptide analytes and carrier ampholytes. Thus, the preparative capabilities of CIEF are inherently greater than most capillary-based electrokinetic separation techniques. To further increase sample loading and, therefore, the concentrations of focused analytes, a dynamic approach, which is based on electrokinetic injection of proteins/peptides from a solution reservoir, is demonstrated using a low p/ protein calibration kit and tryptic peptides from Saccharomyces cerevisiae. The proteins/peptides continuously migrate into the capillary and encounter a pH gradient established by carrier ampholytes originally present in the capillary for focusing and separation. Dynamic introduction and focusing in CIEF can be directly controlled by various electrokinetic conditions, including the injection time and the applied electric field strength. Differences in the sample loading are contributed by electrokinetic injection bias and are affected by the individual analyte's electrophoretic mobility. Depending on the mobilities of yeast peptides, the loading capacity of each peptide is measured to be around 8 to 45-fold of that obtained in conventional CIEF. By comparing with the concentrations of dilute yeast peptides originally present in the reservoir, an overall concentration factor of 1400-7700 together with excellent separation resolution is achieved using dynamic introduction and focusing. This concentration effect is further illustrated by detecting 10 pg/microL of bradykinin peptide spiked in yeast protein digest using only ultraviolet absorption.  相似文献   

10.
Sample introduction of an imaged capillary isoelectric focusing (cIEF) instrument is fully automated by using commercially available high-performance liquid chromatography (HPLC) injection valves and autosamplers. Sample carryover can be controlled to under 1% when the valve and separation column are washed for 1 min between sample runs. The standard deviation of peak areas for 20 injections is 3.5%, which includes deviations created by the absorption imaging detector and the isoelectric focusing process inside the 75 μm I.D. column. Sample throughput is up to 10 samples per hour. The instrument has been applied to fast analysis of many proteins including monoclonal antibodies.  相似文献   

11.
Immobilized pH gradients isoelectric focusing (IPG-IEF) is the first dimension typically used in two-dimensional gel electrophoresis (2-DE). It can also be used on its own in conjunction with tandem mass spectrometry (MS/MS) for the analysis of proteins. Here, we described a strategy combining isoelectric focusing in immobilized pH gradient strips, and mass spectrometry to create a new high-throughput and sensitive detection method. Protein mixture is separated by in-gel IEF, then the entire strip is cut into a set of gel sections. Proteins in each gel section are digested with trypsin, and the resulted peptides are subjected to reversed-phase high performance liquid chromatography followed by electrospray-linear ion-trap tandem mass analysis. Using this optimized strategy, we have identified 744 distinct human proteins from an IPG strip loaded only 300 microg of plasma proteins. When compared with other works in published literatures, this study offered a more convenient and sensitive method from gel to mass spectrometry for the separation and identification proteins of complex biological samples.  相似文献   

12.
Anionic or acidic proteins are the main compositions of normal urinary proteome. Efforts to characterize human urinary proteome, thus, have focused mainly on the anionic compartment. The information of cationic or basic proteins present in the normal urine is virtually unknown. In the present study, we applied different methods to enrich cationic urinary proteome. Efficacies of these methods were compared using equal volume (1 L) of urine samples from the same pool obtained from 8 normal healthy individuals. Cation exchange chromatography using RESOURCE-S column provided the least amount of the recovered proteins, whereas batch adsorption using SP Sepharose 4 Fast Flow beads equilibrated with acetic acid (pH 4.8) provided the greatest yield of protein recovery. The recovered proteins were then resolved with 2-DE (pI 7-11) and identified by peptide mass fingerprinting using MALDI-TOF MS. There were several isoforms of immunoglobulin heavy and light chains enriched by these methods. In addition, three isoforms of interferon alpha-3 (IFNalpha3) and six isoforms of eosinophil-derived neurotoxin (EDN), were also enriched. The enrichment of IFNalpha3 and EDN was particularly effective by batch adsorption using SP Sepharose 4 Fast Flow beads equilibrated with acetic acid (pH 6.0). Initial depletion of anionic components using DEAE batch adsorption reduced the recovery yield of these two proteins and did not improve recovery of any other cationic urinary proteins. We conclude that batch adsorption using SP Sepharose Fast Flow beads equilibrated with acetic acid (pH 6.0) is the method of choice to examine the basic/cationic urinary proteome, as this protocol provided the satisfactory yield of protein recovery and provided the greatest amount as well as maximal number of IFNalpha3 and EDN isoforms. Our data will be useful for further highly focused study targeting on cationic/basic urinary proteins. Moreover, the techniques described herein may be applicable for enrichment of cationic proteomes in other body fluids, cells, and tissues.  相似文献   

13.
Recently, we have developed a high-resolution two-dimensional separation strategy for the analysis of complex peptide mixtures. This methodology employs isoelectric focusing of peptides on immobilized pH gradient (IPG) gels in the first dimension, followed by reversed-phase chromatography in the second dimension, and subsequent tandem mass spectrometry analysis. The traditional approach to this mixture problem employs strong-cation-exchange (SCX) chromatography in the first dimension. Here, we present a direct comparison of these two first-dimensional techniques using complex protein samples derived from the testis of Rattus norvegicus. It was found that the use of immobilized pH gradients (narrow range pH 3.5-4.5) for peptide separation in the first dimension yielded 13% more protein identifications than the optimized off-line SCX approach (employing the entire pI range of the sample). In addition, the IPG technique allows for a much more efficient use on mass spectrometer analysis time. Separation of a tryptic digest derived from a rat testis sample on a narrow range pH gradient (over the 3.5-4.5 pH range) yielded 7626 and 2750 peptides and proteins, respectively. Peptide and protein identification was performed with high confidence using SEQUEST in combination with a data filtering program employing pI and statistical based functions to remove false-positives from the data.  相似文献   

14.
15.
An isoelectric focusing gel system is described which produces a pH gradient spanning the range 4–9. When chick brain mitochondrial polypeptides were focused on such a gel, extra polypeptide spots were observed in the basic region which were not seen in a gel prepared by conventional methods.  相似文献   

16.
One method of improving the protein profiling of complex mammalian proteomes is the use of prefractionation followed by application of narrow pH range two dimensional (2-D) gels. The success of this strategy relies on sample solubilization; poor solubilization has been associated with missing protein fractions and diffuse, streaked, and/or trailing protein spots. In this study, I sought to optimize the solubilization of prefractionated human cancer cell samples using isoelectric focusing (IEF) rehydration buffers containing a variety of commercially available reducing agents, detergents, chaotropes, and carrier ampholytes. The solubilized proteins were resolved on 2-D gels and compared. Among five tested IEF rehydration buffers, those containing 3-[(3-cholamidopropyl)dimethylamino]-1-propane sulfonate (CHAPS) and dithiothreitol (DTT) provided superior resolution, while that containing Nonidet P-40 (NP-40) did not significantly affect protein resolution, and the tributyl phosphine (TBP)-containing buffer yielded consistently poor results. In addition, I found that buffers containing typically high urea and ampholyte levels generated sharper 2-D gels. Using these optimized conditions, I was able to apply 2-D gel analysis successfully to fractionated proteins from human breast cancer tissue MCF-7, across a pH range of 4-6.7.  相似文献   

17.
Forward and reverse (18)O labeling are integrated with solution isoelectric focusing and capillary LC-tandem mass spectrometry to evaluate a new strategy for quantitative proteomics and to study abundance changes in mitochondrial proteins associated with drug resistance in MCF-7 human cancer cells. Galectin-3 binding protein, which is involved in apoptosis, was detected only in the resistant cell line, as a result of reverse labeling. Among 278 proteins identified, 12 were detected with abundances altered at least 2-fold.  相似文献   

18.
In mixed-bed, carrier ampholyte-Immobiline gels, a primary, insolubilized pH gradient is admixed with a secondary, soluble pH gradient generated by amphoteric buffers. The latter are the standard carrier ampholytes (e.g. Ampholine, Pharmalyte, Biolyte, Servalyte), used in conventional isoelectric focusing, admixed to Immobiline gels in levels of approximately 0.5-1%. It is here shown that polybuffers 96 (covering the pH 6-9 range) and 74 (covering the pH 4-7 interval) used as eluents in chromatofocusing, can effectively substitute the standard carrier ampholytes with considerable savings (they are 1/16th as expensive as the latter chemicals).  相似文献   

19.
20.
In this paper we discuss the thermodynamics of ion binding in solution, protein adsorption and ion co-adsorption. The emphasis is on charge regulation effects. To this end, we introduce phenomenological linkage relations from which the ion binding can be calculated from the electrolyte dependency of proton titration curves and the co-adsorption from the electrolyte dependency of protein adsorption isotherms. The linkage relations are derived from classical interfacial thermodynamics, and thus offer an alternative approach as compared to the mass balance equations which are currently used in biotechnology, and Record et al.'s 1978 analysis of Wyman's Binding Polynomial for protein interactions. The co-adsorption theory is an extension of our previous analysis of ion binding in solution, which we include here for comparison of the ion co-adsorption with the ion binding in solution. The theory is applied to the chromatography of lysozyme on the strong cation exchanger ‘mono S’ and to the proton titration of lysozyme in solution. In the accompanying Part 2 of this paper the results are interpreted with a simple model.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号