首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Solid phase extraction (SPE) was coupled at line to capillary electrophoresis (CE) for the determination of three basic and neutral diabetic drugs (metformin, phenformin and glyburide) in human plasma. The SPE procedure employed a C(18) cartridge to remove most of the water and proteins from the plasma sample. Analyte detectability was increased due to trace enrichment during the SPE process. Elution of metformin, phenformin and glyburide was achieved with methanol+3% acetic acid. CE analysis was performed using a non-aqueous buffer, acetonitrile+5mM ammonium acetate+5% acetic acid, which afforded rapid separation of metformin from phenformin within 3 min. Glyburide, with a migration time longer than 6 min, did not cause any interference. The present SPE-CE method, with an electrokinetic injection time of 6s and UV detection at 240 nm, was useful for monitoring down to 1 microg/mL of metformin and phenformin in human plasma. When the electrokinetic injection time was increased to 36s, the detection limits were improved to 12 ng/mL for metformin and 6 ng/mL for phenformin.  相似文献   

2.
The combination of capillary electrophoresis (CE) and mass spectrometry (MS) with solid-phase extraction (SPE) has been used for the identification of nicotine and eight of its metabolites in urine. The recovery of cotinine from cotinine-spiked urine, by C18 SPE, was found to be 98%. Smokers urine (200 ml) was preconcentrated 200-fold via SPE prior to analysis. The sample stacking mode of CE, when compared to capillary zone electrophoresis, was shown to improve peak efficiency by 132-fold. The combination of hydrodynamic and electrokinetic injection was studied with sample stacking/CE/MS. The on-column limits of detection (LOD) of nicotine and cotinine, by this technique, were found to be 0.11 and 2.25 microg/ml, respectively. Hence, LODs of nicotine and cotinine in urine after 200-fold preconcentration were 0.55 and 11.25 ng/ml, respectively.  相似文献   

3.
A sensitive method for the determination of Cloretazine (VNP40101M) and its metabolite (VNP4090CE) with an internal standard (ISTD) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Acidified plasma samples (500 microL) were prepared using solid phase extraction (SPE) columns, and 25 microL of the reconstituted sample was injected onto an Ascentis C18 HPLC column (3 microm, 5 cmx2.1 mm) with an isocratic mobile phase. Analytes were detected with an API-3000 LC-MS/MS System at unit (Q1) and low (Q3) resolution in negative multiple reaction monitoring mode: m/z 249.0 (precursor ion) to m/z 114.9 (product ion) for both Cloretazine (at 3.64 min) and VNP4090CE (at 2.91 min), and m/z 253.0 (precursor ion) to m/z 116.9 (product ion) for the ISTD. The mean recovery for Cloretazine (VNP40101M) and its metabolite (VNP4090CE) was greater than 87% with a lower limit of quantification of 1.0 ng/mL for Cloretazine (S/N=9.7, CV相似文献   

4.
Peptidome analysis has received increasing attention in recent years. Cancer diagnosis by serum peptidome has also been reported by peptides' profiling for discovery of peptide biomarkers. Tissue, which may have a higher biomarker concentration than blood, has not been investigated extensively by means of peptidome analysis. Here, a method for the peptidome analysis of mouse liver was developed by the combination of size exclusion chromatography (SEC) prefractionation with nano-liquid chromatography-tamdem mass spectrometry (nanoLC-MS/MS) analysis. The extracted peptides from mouse liver were separated according to their molecular weight using a size exclusion column. MALDI-TOF MS was used to characterize the molecular weight distribution of the peptides in fractions eluted from the SEC column. The low molecular weight (LMW) (MW < 3000 Da) peptides in the collected fractions were directly analyzed by LC-MS/MS which resulted in the identification of 1181 unique peptides (from 371 proteins). The high molecular weight (HMW) (MW > 3000 Da) peptides in the early two fractions from the SEC column were first digested with trypsin, and the resulted digests were then analyzed by LC-MS/MS, which led to the identification of 123 and 127 progenitor proteins of the HMW peptides in fractions 1 and 2, respectively. Analysis of the peptides' cleavage sites showed that the peptides are cleaved in regulation, which may reflect the protease activity and distribution in body, and also represent the biological state of the tissue and provide a fresh source for biomarker discovery.  相似文献   

5.
A method for determination of a gamma-secretase inhibitor, cis-3-[4-[(4-chlorophenyl)sulfonyl]-4-(2,5-difluorophenyl)cyclohexyl]propanoic acid (A), in human plasma and cerebrospinal fluid (CSF) has been developed to support the clinical investigation of compound A for its potential treatment of Alzheimer's disease. The method is based on HPLC with atmospheric pressure chemical ionization tandem mass spectrometric detection (APCI-MS/MS) in the negative ionization mode using a heated nebulizer interface. The addition of phosphoric acid at the ratio of 10-30microL per milliliter of human plasma or CSF was required during clinical sample collection to stabilize an acylglucuronide metabolite (C), which was potentially present in human plasma and CSF. Tween 20 (10% solution) was added at the ratio of 20microL per milliliter of CSF during CSF sample collection to prevent the loss of compound A during the storage of clinical samples. The compound A and its analog internal standard (B) in treated plasma or CSF were isolated from human plasma or CSF using solid phase extraction (SPE) in the 96 well format. The isolated analyte and internal standard were chromatographed on a Phenomenex Synergi Polar RP analytical column (50mmx3.0mm, 4microm), using a mobile phase consisting of 60/40 (v/v, %) acetonitrile/water at a flow-rate of 0.5mL/min. Tandem mass spectrometric detection was performed using a Sciex API 3000 tandem mass spectrometer operated in the multiple reaction monitoring (MRM) mode using precursor to product ion transitions of 441-->175 for A and 469-->175 for B, respectively. The assays were validated over the concentration range of 0.5-200ng/mL for human plasma and CSF. Replicate analyses (n=5) of spiked standards for both assays yielded a linear response with coefficients of variation less than 7% and accuracy within 5% of the nominal concentrations. In addition, the assays were automated to improve sample throughput by utilizing a Packard Multi PROBEII automated liquid handling system and a Tom-Tec Quadra 96 system. Numerous clinical studies have been supported using these assays.  相似文献   

6.
An improved liquid chromatographic method with on-line solid phase extraction (SPE) and tandem mass spectrometric detection was optimised for quantification of the anti-HIV peptide Sifuvirtide in human plasma. The SPE sorbents, loading buffer composition and other aspects of the on-line SPE column were investigated in detail for efficiently extracting the interesting peptides and simultaneously discarding the large amount of proteins. The gradient elution program was optimised on the analysis column to decrease the matrix effect and obtain excellent selectivity. The multiple charge ion at m/z 946.4 of Sifuvirtide was quantified by a linear ion trap mass spectrometer, operating in the positive mode, and selective reaction monitoring (SRM) acquisition. Method validation results demonstrated that the linear calibration curve covered a range of 6.1–6250 ng/mL, and the correlation coefficients (r2) were above 0.992. The lower limit of detection (LLOD) with a signal-to-noise (S/N) ratio higher than 10 was 6.1 ng/mL. The accuracy ranged from −7.6 to 10.6%, and the intra- and inter-batch precisions were less than 8.7% and 5.5%, respectively. Finally, more than nine hundred of samples from a clinical trial was completely analyzed using this on-line SPE coupled HPLC–MS/MS system in one single week, due to the rapid run-time of individual sample (6.5 min).  相似文献   

7.
A method based on solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) was developed for the simultaneous determination of 3-(3,5-diclorophenyl)-5-ethenyl-5-methyl-2,4-oxazolidinedione (vinclozolin) and 3-(3,5-diclorophenyl)-N-(1-methylethyl)-2,4-dioxo-1-imidazolidinecarboxamide (iprodione) in human urine. Urine samples containing vinclozolin and iprodione were collected by solid phase extraction using C(18) cartridges. The chromatographic separation was achieved on a Spherisorb ODS2 (250 mm x 4.6 mm, 5 microm) column with an isocratic mobile phase of acetonitrile-water (60:40, v/v). Detection was UV absorbance at 220 nm. The calibration graphs were linear from 30 to 1000 ng/mL for the two fungicides. Intra- and inter-day R.S.D. did not exceed 2.9%. The quantitation limit was 50 ng/mL for vinclozolin and 30 ng/mL for iprodione, respectively.  相似文献   

8.
To support pharmacokinetic studies, a selective and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous determination of a novel KDR kinase inhibitor (1) and its active metabolite (2) in human plasma. The method is fully automated using a Packard MultiPROBE II system and a TomTec Quadra 96 liquid handling workstation to perform sample preparation and solid-phase extraction (SPE). Following the extraction on a mixed-mode SPE using Oasis MCX 96-well plate, the analytes were separated on a Aquasil C18 column (50 mm x 2.1 mm, i.d., 3 microm) with a mobile phase consisting of acetonitrile/ammonium acetate buffer (5 mM, pH 5.0) (60/40, v/v). The run time for each injection was 4.5 min with the retention times of approximately 2.0 and 2.7 min for 1 and 2 respectively, at a flow rate of 0.25 mL/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring (MRM) under the positive ion mode with a turbo ion-spray interface. The linear ranges of the calibration curves were 0.05-400 ng/mL for 1 and 0.1-400 ng/mL for 2 on a PE Sciex API 4000 LC-MS/MS system. The lower limits of quantitation (LLOQ) of the assay were 0.05 and 0.1 ng/mL for 1 and 2 respectively, when 0.4 mL of plasma was processed. Intra-day assay precision (using five standard curves prepared by spiking compounds to five lots of plasma) was less than 4.9% for 1 and less than 9.6% for 2 on each concentration. Assay accuracy was found to be 95.1-104.6% of nominal for 1 standards and 93.5-105.6% for 2 standards. QC samples were stable when kept at room temperature for 4 h, at -70 degrees C for 10 days, and after three freeze-thaw cycles. The extraction recoveries were 80%, 83% and 84% for 1 and 2 and I.S. respectively, and no significant matrix effects were observed. The method was successfully applied to plasma samples from clinical studies after oral administration of compound 1.  相似文献   

9.
A high-performance micellar electrokinetic capillary chromatography (MEKC) has been demonstrated for the determination of meropenem in human plasma and in cerebrospinal fluid (CSF) and application in meningitis patients after intravenous (IV) administration. Plasma sample was pretreated by means of solid-phase extraction (SPE) on C(18) cartridge and CSF sample was by direct injection without sample pretreatment, with subsequent quantitation by MEKC. The separation of meropenem was carried out in an untreated fused-silica capillary (40.2 cm x 50 microm I.D., effective length 30 cm) and was performed at 25 degrees C using a background electrolyte consisting of Tris buffer (40 mM, pH 8.0) solution with sodium dodecyl sulfate (SDS) as the running buffer and on-column detection at 300 nm. Several parameters affecting the separation and sensitivity of the drug were studied, including pH, the concentrations of Tris buffer and surfactant. Using cefotaxime as an internal standard (IS), the linear ranges of the method for the determination of meropenem in plasma and in CSF were all over 0.5-50 microg/mL; the detection limits (signal-to-noise ratio=3) of meropenem in plasma and in CSF were 0.2 microg/mL and 0.3 microg/mL, respectively.  相似文献   

10.
The double coating principle of CEofix buffers was evaluated for the analysis of some basic drugs by capillary electrophoresis-diode-array detection (CE-DAD) and capillary electrophoresis-mass spectrometry (CE-MS). The involatile phosphate present in original low pH CEofix, was replaced with formic acid for hyphenation of CE with MS. The double coating produces a substantial and highly reproducible electroosmotic flow (EOF), even at low pH. The rinsing procedure and electrolyte composition were optimized for both CE-DAD and CE-MS. The system was evaluated with the analysis of a mixture of basic drugs and a spiked urine sample enriched by solid-phase extraction (SPE). The R.S.D. values on the migration time and peak area measured for 28 analyses with CE-DAD were below 0.25 and 2.40%, respectively. For CE-MS, the R.S.D. on the migration time was 0.85% or less and the area precision ranged from 5.65 to 14.33% (for seven injections). The LOD with the developed CE-MS method was below 50 ppb for all five drug standards tested.  相似文献   

11.
In the csf of rats, the concentration of peptides, reacting with antibody to leu-enkephalin, was determined by radioimmunoassay. Intravenous injection of morphine caused a biphasic response, i.e. an immediate and a delayed rise of the level of such immunoreactive peptides in the csf. After i.v. naloxone, only the late peak was observed. Combined administration of morphine and naloxone delayed the appearance of the first peak, expected after morphine injection; the second peak did not show within 2 – 3 hours. The results are interpreted by assuming release of enkephalins and related peptides from two sites, viz. synaptic clefts and intracellular pools.  相似文献   

12.
Two novel methods for the analysis of ellagic acid in pomegranate (Punica granatum) rinds are proposed. Capillary electrophoresis (CE) was performed in a bare fused-silica capillary using a buffer solution of tri(hydroxymethyl)aminomethane:potassium dihydrogen phosphate (pH 8.4) with an applied voltage of 20 kV and UV detection at 254 nm. HPLC analysis was performed with a Zobax SB C(18) column and a mobile phase consisting of methanol:ethyl acetate:potassium dihydrogen phosphate: phosphoric acid at a flow rate of 1.0 mL/min. Under optimised conditions, the HPLC retention and the CE migration times for ellagic acid were 10.32 and 12.23 min, respectively. Calibration curves of peak area vs. concentration gave correlation coefficients of 0.9999 for HPLC and 0.9990 for CE. The detection limits for HPLC and CE were 2.8 and 2.2 microg/mL, respectively. Average recoveries were 98.32 +/- 1.2% for HPLC and 96.52 +/- 2.8% for CE. Both methods were shown to be suitable for the determination of ellagic acid in pomegranate rinds extraction; however, the CE method required less solvent and gave better column efficiency, whilst the HPLC provided superior precision.  相似文献   

13.
In the present work, for the first time, a method for the quantification of the alimentary opioid peptide Gluten Exorphin A5 (GE-A5; Gly-Tyr-Tyr-Pro-Thr) in cerebrospinal fluid (CSF) was developed. Aliquots (5 microL) of CSF were injected into a liquid chromatography-mass spectrometry (LC-MS) instrument equipped with a reversed-phase C18 column at a flow-rate of 0.4 mL/min. The mobile phase consisted of Eluent A water with 0.6% acetic acid as an ion-pairing reagent and Eluent B acetonitrile/methanol (75:25, v/v). The LC-MS system was programmed to divert column flow to waste for 4 min after injection, after which time flow was directed into the mass spectrometer that operated in positive ion mode. No significant interfering peaks were detected at the retention times of GE-A5 in CSF blanks. The lower limit of detection and the lower limit of quantitation values for GE-A5 in CSF were established at 0.60 and 1.50 ng/mL, respectively. The intra- and inter-day precision values were <5% relative standard deviation. The intra- and inter-day accuracy were 99.6-102.8% and 100.0-101.9%, respectively. The reported assay employs extremely small volumes of CSF, thus allowing the analysis of GE-A5 from both small and large animal models.  相似文献   

14.
Immunoreactive dynorphin (I-dynorphin) was measured by radioimmunoassay in human cerebrospinal fluid (CSF). I-dynorphin concentration in CSF was 30 +/- 2 pg/ml. Sephadex G-25 column chromatography showed the main peak eluted at the position of dynorphin-(1-17). HPLC elution profile of this major peak from gel filtration showed a large peak corresponding to the position of dynorphin-(1-17) and small peaks corresponding to the positions of dynorphin-(1-13), dynorphin-(1-12) and other unknown peptides.  相似文献   

15.
A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.  相似文献   

16.
Cerebrospinal fluid (CSF) potentially carries an archive of peptides and small proteins relevant to pathological processes in the central nervous system (CNS) and surrounding brain tissue. Proteomics is especially well suited for the discovery of biomarkers of diagnostic potential in CSF for early diagnosis and discrimination of several neurodegenerative diseases. ProteinChip surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) is one such approach which offers a unique platform for high throughput profiling of peptides and small proteins in CSF. In this study, we evaluated methodologies for the retention of CSF proteins < 20 kDa in size, and identify a strategy for screening small proteins and peptides in CSF. ProteinChip array types, along with sample and binding buffer conditions, and matrices were investigated. By coupling the processing of arrays to a liquid handler reproducible and reliable profiles, with mean peak coefficients of variation < 20%, were achieved for intra- and inter-assays under selected conditions. Based on peak m/z we found a high degree of overlap between the tested array surfaces. The combination of CM10 and IMAC30 arrays was sufficient to represent between 80–90% of all assigned peaks when using either sinapinic acid or α-Cyano-4-hydroxycinnamic acid as the energy absorbing matrices. Moreover, arrays processed with SPA consistently showed better peak resolution and higher peak number across all surfaces within the measured mass range. We intend to use CM10 and IMAC30 arrays prepared in sinapinic acid as a fast and cost-effective approach to drive decisions on sample selection prior to more in-depth discovery of diagnostic biomarkers in CSF using alternative but complementary proteomic strategies.  相似文献   

17.
A fast and simple method based on capillary electrophoresis (CE) with chemiluminescence (CL) detection has been developed for the determination of agmatine, a recently identified neurotransmitter/modulator. The CE run time was approximately 2 min for each sample injected. CL detection employed a lab-built reaction flow cell and a photon counter. The CL reagents used were luminol and NaBrO. The optimized conditions for the CL detection were 5 x 10(-4)M luminol added to the CE running buffer and 5.0 x 10(-4)M NaBrO in 100 mM NaCO3-NaOH buffer solution at pH 12.5 introduced post column. Detection limit for agmatine was 4.3 x 10(-6)M (S/N=3). The precision (R.S.D.) on peak height (at 1 x 10(-5)M agmatine) and migration time were 3.7 and 2.5%, respectively. The present CE-CL method was evaluated with the determination of agmatine in tissue samples taken from rat brain, and rat and monkey stomachs. Samples were directly injected into the CE-CL system after the removal of proteins. A higher level of agmatine was detected in the stomach samples. Agmatine concentrations in the tissue samples taken from rat and monkey stomachs were similar at approximately 1950 ng/g wet tissue.  相似文献   

18.
A method based on solid-phase extraction (SPE) and capillary zone electrophoresis (CZE) for the analysis of tobramycin in human serum is presented. An off-line SPE employing a carboxypropyl bonded phase (CBA) cartridge was used for the extraction of tobramycin from human serum. Adsorbed tobramycin was eluted from the CBA cartridge using a mixture of NH(3) (25%, w/v)-methanol (30:70, v/v). After evaporation, the analyte was reconstituted and derivatized with o-phthaldialdehyde (OPA)/3-mercaptopropionic acid (MPA). The resulting tobramycin-OPA/MPA derivative was purified, and then identified by mass spectrometry. The tobramycin-OPA/MPA derivative was then analysed by CZE with a background electrolyte (BGE) comprising of 30 mM sodium tetraborate pH 10.0-acetonitrile (ACN) (80:20, v/v) with ultraviolet detection at 230 nm. A linear response was observed in the range of 0.3-30 microg/ml with r(2) = 0.992. The sensitivity of the method was determined by its limit of quantitation (LOQ) and limit of detection (LOD) of 0.3 microg/ml and 0.1 microg/ml, respectively. SPE recovery ranged from 68 to 79% at the trough levels to 98% at the peak levels found in serum. Furosemide has been added as internal standard (IS) to improve precision. For the therapeutic range of tobramycin in serum (2-10 microg/ml) the relative standard deviation (R.S.D.) was less than 11% for the entire SPE/CE process. The method demonstrated excellent selectivity as shown by the lack of interference from a total of 20 drugs investigated. The method was then used in therapeutic drug monitoring of patients receiving the drug.  相似文献   

19.
A sensitive, precise and accurate method for the quantification of the alimentary opioid peptide Gluten Exorphin B5 (GE-B5, Tyr-Gly-Gly-Trp-Leu) in cerebrospinal fluid (CSF) was developed using liquid chromatography-mass spectrometry (LC-MS). Aliquots (10 microL) of sheep CSF were injected into a LC-MS instrument equipped with a reversed-phase C12 column at a flow rate of 250 microL/min. The mobile phase consisted of Eluent A water with 0.01% acetic acid as an ion-pairing reagent, and Eluent B acetonitrile. The LC-MS system was programmed to divert column flow to waste for 3.5 min after injection, after which time flow was directed into the mass spectrometer that operated in positive ion mode. DADLE (Tyr-D-Ala-Gly-Phe-D-Leu) was used as Internal Standard. No significant interfering peaks were detected at the retention times of GE-B5 in CSF blanks. The calibration curves were linear in the range of 0.39-78.00 ng/mL. The lower limit of detection and the lower limit of quantitation values for GE-B5 in CSF were established at 0.30 and 0.78 ng/mL, respectively. The intra-day and inter-day precision values were <12% relative standard deviation. The intra-day and inter-day accuracy were 99.46-100.86% and 98.95-100.02%, respectively. Recovery of GE-B5 in CSF samples was greater than 80%. Stability studies indicate that GE-B5 in CSF undergoes significant degradation (>55% after 600 min), which is reduced by the addition of protease inhibitors. This is the first reported method for the quantification of GE-B5 in CSF.  相似文献   

20.
A sensitive and reliable method for the determination of gamma-aminobutyric acid (GABA), a major inhibitory neurotransmitter, in human plasma and cerebrospinal fluid (CSF) has been developed. The method is based on capillary liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using deuterium-labeled GABA (gamma-aminobutyric acid-2,2-D(2), GABA-d(2)) as internal standard. Pre-column derivatization with 7-fluoro-4-nitrobenzoxadiazole (NBD-F) was deployed, allowing both effective in-line pre-concentration and sensitive tandem MS detection of the analyte. An extraction column (10 mm x 0.25 mm, 7 microm, C(18)) was used for preconcentrating and stacking the sample. Separation was carried out on an analytical column (50 mm x 0.25 mm, 5 microm, C(18)). Characteristic precursor-to-product ion transitions, m/z 267--> 249 (for NBD-GABA) and m/z 269--> 251 (for NBD-GABA-d(2)) were monitored for the quantification. A linear calibration curve from 10 to 250 ng/mL GABA with an r(2) value of 0.9994 was obtained. Detection limit was estimated to be 5.00 ng/mL GABA (S/N = 3). Human plasma and CSF samples were analyzed. The concentrations of GABA were found to be 98.6 +/- 33.9 ng/mL (mean +/- S.D., n = 12), and 44.3 +/- 10.0 ng/mL (n = 6) in plasma and CSF, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号