首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An index of airway caliber can be tracked in near-real time by measuring airway resistance (Raw) as indicated by lung resistance at 8 Hz. These measurements require the placing of an esophageal balloon. The objective of this study was to establish whether total respiratory system resistance (Rrs) could be used rather than Raw to track airway caliber, thereby not requiring an esophageal balloon. Rrs includes the resistance of the chest wall (Rcw). We used a recursive least squares approach to track Raw and Rrs at 8 Hz in seven healthy and seven asthmatic subjects during tidal breathing and a deep inspiration (DI). In both subject groups, Rrs was significantly higher than Raw during tidal breathing at baseline and postchallenge. However, at total lung capacity, Raw and Rrs became equivalent. Measured with this approach, Rcw appears volume dependent, having a magnitude of 0.5-1.0 cmH2O. l-1. s during tidal breathing and decreasing to zero at total lung capacity. When resistances are converted to an effective diameter, Rrs data overestimate the increase in diameter during a DI. Simulation studies suggest that the decrease in apparent Rcw during a DI is a consequence of airway opening flow underestimating chest wall flow at increased lung volume. We conclude that the volume dependence of Rcw can bias the presumed net change in airway caliber during tidal breathing and a DI but would not distort assessment of maximum airway dilation.  相似文献   

2.
Allergic bronchoconstriction may be associated with hemodynamic alterations due to changes in respiratory mechanics (or the associated changes in arterial blood gas composition) or the cardiovascular effects of chemical mediators. In an attempt to differentiate between these two possible mechanisms, we obtained measurements of hemodynamics, respiratory mechanics, and O2 consumption (VO2) in nine asymptomatic adult ragweed asthmatics before and after inhalation challenge with either ragweed extract or methacholine. We measured specific airway conductance (sGaw) by body plethysmography, pleural pressure with an esophageal balloon catheter, pulmonary blood flow (Q) and VO2 by a rebreathing technique, and heart rate. For a similar degree of bronchoconstriction after the two types of challenge (mean +/- SD sGaw 0.06 +/- 0.03 and 0.05 +/- 0.02 cmH2O-1 . s-1, P = NS), mean Q increased by 29 and 29%, and mean VO2 by 33 and 37% 15-20 min after ragweed and methacholine, respectively. Since heart rate did not change, there was a concomitant increase in mean stroke volume by 25 and 35%, respectively (P less than 0.05). The respiratory pleural pressure swings during quiet breathing and the rebreathing maneuver and the work of breathing during rebreathing also increased to a similar degree after the two types of challenge. These observations suggest that, if chemical mediators are released into the circulation during antigen-induced bronchoconstriction, their blood concentrations are too low for appreciable cardiovascular effects. The increase in rebreathing cardiac output during allergic and nonallergic bronchoconstriction is probably due to increases in intrathoracic pressure swings and in the work of breathing.  相似文献   

3.
A mouthpiece plus noseclip (MP + NC) is frequently used in performing measurements of breathing patterns. Although the effects the apparatus exerts on breathing patterns have been studied, the mechanism of the changes it causes remains unclear. The current study examines the effects on respiratory patterns of a standard (17-mm-diam) MP + NC during room air (RA) breathing and the administration of 2 and 4% CO2 in normal volunteers and in patients 2-4 days after abdominal operation. When compared with values obtained with a noninvasive canopy system, the MP + NC induced increases in minute ventilation (VE), tidal volume (VT), and mean inspiratory flow (VT/TI), but not frequency (f) or inspiratory duty cycle, during both RA and CO2 administration. The percentage increase in VE, VT, and VT/TI caused by the MP + NC decreased as the concentration of CO2 increased. During RA breathing, the application of noseclip alone resulted in a decrease in f and an increase in VT, but VE and VT/TI were unchanged. The changes were attenuated during the administration of 2 and 4% CO2. Reducing the diameter of the mouthpiece to 9 mm abolished the alterations in breathing pattern observed with the larger (17-mm) diameter MP.  相似文献   

4.
We examined the influence of lung volume on the ability of normal subjects to sustain breathing against inspiratory resistive loading. Four normal subjects breathed on a closed circuit in which inspiration was loaded by a flow resistor. Subjects were assigned a series of breathing tasks over a range of pressures and flows. In each task there was a specified resistor and also targets for either mean esophageal or airway opening pressure, respiratory frequency, and duty cycle. Endurance was assessed as the length of time to failure of the assigned task. The prime experimental variable was lung volume, which was increased by approximately 1 liter during some tasks; 8 cmH2O continuous positive airway pressure was applied to increase lung volume without increasing elastic load. As previously shown (McCool et al.J. Appl. Physiol. 60: 299-303, 1986), for tasks that could be sustained for the same time, there was an inverse linear relationship of mean esophageal pressure with inspiratory flow rate. This trade-off of pressure and flow was apparent both with and without the increase of lung volume. Comparable tasks, however, could not be sustained as long at the higher lung volumes. This effect of volume on endurance was greater for tasks characterized by high inspiratory pressures and low flow rates than for tasks that could be sustained for the same time but that had lower inspiratory pressures and higher flow rates. This is probably due to the effects of shortening of the sarcomere on fatiguability. Increased lung volume, per se, may contribute to respiratory failure because of increased inspiratory muscle fatiguability by mechanisms independent of elastic load.  相似文献   

5.
Because the pleural pressure gradient and regional distribution of pulmonary function are gravity dependent, substantial changes may be expected during weightlessness. Although very few measurements have been made during spaceflights, a number of observations during brief periods of weightlessness inside aircraft flying with parabolic trajectories confirm these predictions. Single-breath N2 washouts suggest a marked reduction in the inequality of ventilation distribution seen at 1 G. Similarly, inferences made from cardiogenic oscillations during single-breath washouts suggest a greater uniformity of perfusion during weightlessness. This is supported by changes seen on chest radiographs as well as by more direct measurements of regional blood flow distribution using radioactive iodine-labeled macroaggregates. Vital capacity is only slightly reduced, but functional residual capacity decreases by approximately 10% and maximum expiratory flow rates are slightly decreased, especially at low lung volumes. Weightlessness decreases abdominal girth, increases abdominal compliance, and substantially increases the abdominal contribution to tidal volume during resting breathing. Despite these changes, there does not appear to be any alteration in the temporal pattern of breathing. However, the deposition of inhaled medium-sized aerosol particles is substantially reduced, as predicted by model analyses of gravitational sedimentation. Virtually all these observations describe effects at the very onset of weightlessness. Practically nothing is known of slower functional changes and adaptations to prolonged weightlessness. Systematic repeated measurements during manned spaceflights will hopefully begin to provide some information on this subject in the near future.  相似文献   

6.
Chest wall distortion (inward motion of the rib cage on inspiration) has been found recently to reduce the tidal volume during active sleep in the neonatal period. To determine some of the factors that relate to the chest wall distortion and the decreased tidal volume seen in active sleep, a quantification of the phase differences between the movements of the chest wall and those of the abdominal wall, and of the relation of their phase differences to tidal volume was performed on data obtained before and during carbon dioxide stimulation in 15 newborn infants sleeping in the prone position. In quiet sleep, the breathing movements were congruent and regular, and the tidal volume and the mean inspiratory flow increased during carbon dioxide stimulation. In active sleep during exposure to carbon dioxide, the chest wall distortion decreased, the breathing movements were incongruent and the degree of the chest wall distortion was negatively correlated with the tidal volume, while the tidal volume and the mean inspiratory flow was increased. Chest wall distortion did not appear in quiet sleep and was decreased in active sleep in spite of increased ventilation during CO2 stimulation. This study favours the idea that chest wall distortion is caused by a well regulated change in neuromuscular activity and not by the strength of diaphragmatic movements overcoming the mechanical stability of the rib cage.  相似文献   

7.
Steady-state breathing patterns on mouthpiece and noseclip (MP) and face mask (MASK) during air and chemostimulated breathing were obtained from pneumotachometer flow. On air, all 10 subjects decreased frequency (f) and increased tidal volume (VT) on MP relative to that on MASK without changing ventilation (VE), mean inspiratory flow (VT/TI), or mean expiratory flow (VT/TE). On elevated CO2 and low O2, MP exaggerated the increase in VE, f, and VT/TE due to profoundly shortened TE. On elevated CO2, MASK exaggerated VT increase with little change in f. Increased VE and VT/TI were thus due to increased VT. During low O2 on MASK, both VT and f increased. During isocapnia, shortened TE accounted for increased f; during hypocapnia, increased f was related primarily to shortened TI. Thus the choice of a mouthpiece or face mask differentially alters breathing pattern on air and all components of ventilatory responses to chemostimuli. In addition, breathing apparatus effects are not a simple consequence of a shift from oronasal to oral breathing, since a noseclip under the mask did not change breathing pattern from that on mask alone.  相似文献   

8.
Spectral analysis of breathing pattern in man   总被引:1,自引:0,他引:1  
The periodic oscillations of breathing pattern parameters were studied in 34 healthy subjects. In a three minutes' resting spirometric recording we determined the duration of inspiration, expiration and tidal volume in successive breaths and computed autocorrelation functions and power spectral density. Ten of the subjects were re-examined 2 years later. Pulmonary functions were examined in all of them. Rhythmic changes lasting several respiratory cycles were found in the breathing pattern. Rhythmic changes in the duration of inspiration, expiration and tidal volume differed from one another in the same individual. The spectrograms of the individual breathing pattern parameters in the same individual changed during a 2-year period. Despite individual differences, the power spectral density correlations in the same subject and between different subjects two years later, and the mean curves for power spectral densities, show that in all the subjects the power fell at values of 0 to 0.05 Hz and was then maintained at a roughly constant level. Differences in the spectrograms of the various parameters in the same subject can hardly be attributed to a feedback between peripheral receptors and respiratory centres. Rhythmic changes are probably of central origin.  相似文献   

9.
The effect of decreased lung volume on ventilatory responses to arteriovenous fistula-induced increased cardiac output was studied in four chronic awake dogs. Lung volume decreases were imposed by application of continuous negative-pressure breathing of -10 cmH2O to the trachea. The animals were surgically prepared with chronic tracheostomy, indwelling carotid artery catheter, and bilateral arteriovenous femoral shunts. Control arteriovenous blood flow was 0.5 l/min, and test flow level was 2.0 l/min. Arterial blood CO2 tension (PaCO2) was continuously monitored using an indwelling Teflon membrane mass spectrometer catheter, and inhaled CO2 was given to maintain isocapnia throughout. Increased fistula flow alone led to a mean 52% increase in cardiac output (CO), whereas mean systemic arterial blood pressure (Psa) fell 4% (P less than 0.01). Negative-pressure breathing alone raised Psa by 3% (P less than 0.005) without a significant change in CO. Expired minute ventilation (VE) increased by 27% (P less than 0.005) from control in both of these conditions separately. Combined increased flow and negative pressure led to a 50% increase in CO and 56% increase in VE (P less than 0.0025) without any significant change in Psa. Effects of decreased lung volume and increased CO appeared to be additive with respect to ventilation and to occur under conditions of constant PaCO2 and Psa. Because both decreased lung volume and increased CO occur during normal exercise, these results suggest that mechanisms other than chemical regulation may play an important role in the control of breathing and contribute new insights into the isocapnic exercise hyperpnea phenomenon.  相似文献   

10.
When a subject breathes against an inspiratory resistance, the inspiratory pressure, the inspiratory flow, and the lung volume at which the breathing task takes place all interact to determine the length of time the task can be sustained (Tlim). We hypothesized that the mechanism actually limiting tasks in which these parameters were varied involved the rate of energy utilization by the inspiratory muscles. To test this hypothesis, we studied four experienced normal subjects during fatiguing breathing tasks performed over a range of pressures and flows and at two different lung volumes. We assessed energy utilization by measuring the increment in the rate of whole body O2 consumption due to the breathing task (VO2 resp). Power and mean esophageal pressure correlated with Tlim but depended also on lung volume and inspiratory flow rate. In contrast, VO2 resp closely correlated with Tlim, and this relationship was not systematically altered by inspiratory flow or lung volume. The shape of the VO2 resp vs. Tlim curve was approximately hyperbolic, with high rates of VO2 resp associated with short endurance times and lower rates of VO2 resp approaching an asymptotic value at high Tlim. These findings are consistent with a mechanism whereby a critical rate of energy utilization determines the endurance of the inspiratory pump, and that rate varies with pressure, flow, and lung volume.  相似文献   

11.
During resting breathing, expiration is characterized by the narrowing of the vocal folds which, by increasing the expiratory resistance, raises mean lung volume and airway pressure. This is even more pronounced in the neonatal period, during which expirations with short complete airway closure are commonly occurring. We asked to which extent differences in expiratory flow pattern may modify the inspiratory impedance of the respiratory system. To this aim, newborn puppies, piglets, and adult rats were anesthetized, paralyzed, and ventilated with different expiratory patterns, (a) no expiratory load, (b) expiratory resistive load, and (c) end-inspiratory pause. The stroke volume of the ventilator and inspiratory and expiratory times were maintained constant, and the loads were adjusted in such a way that inflation always started from the resting volume of the respiratory system. After 1 min of each ventilatory pattern, mean inspiratory impedance and compliance of lung and respiratory system were measured. The values were unchanged or minimally altered by changing the type of ventilation. We conclude that the expiratory laryngeal loading is not primarily aimed to decrease the work of breathing. It is conceivable that the expiratory pattern is oriented to increase and control mean airway pressure in the regulation of pulmonary fluid reabsorption, distribution of ventilation, and diffusion of gases.  相似文献   

12.
Breathing responses to small inspiratory threshold loads in humans.   总被引:1,自引:0,他引:1  
To investiage the effect of inspiratory threshold load (ITL) on breathing, all previous work studied loads that were much greater than would be encountered under pathophysiological conditions. We hypothesized that mild ITL from 2.5 to 20 cmH2O is sufficient to modify control and sensation of breathing. The study was performed in healthy subjects. The results demonstrated that with mild ITL 1) inspiratory difficulty sensation could be perceived at an ITL of 2.5 cmH2O; 2) tidal volume increased without change in breathing frequency, resulting in hyperpnea; and 3) although additional time was required for inspiratory pressure to attain the threshold before inspiratory flow was initiated, the total inspiratory muscle contraction time remained constant. This resulted in shortening of the available time for inspiratory flow, so that the tidal volume was maintained or increased by significant increase in mean inspiratory flow. On the basis of computer simulation, we conclude that the mild ITL is sufficient to increase breathing sensation and alter breathing control, presumably aiming at maintaining a certain level of ventilation but minimizing the energy consumption of the inspiratory muscles.  相似文献   

13.
The aim of this study was to investigate the effect of growth on ventilation and breathing pattern during maximal exercise oxygen consumption (VO2max) and their relationships with anthropometric characteristics. Seventy six untrained schoolboys, aged 10.5-15.5 years, participated in this study. Anthropometric measurements made included body mass, height, armspan, lean body mass, and body surface area. During an incremental exercise test, maximal ventilation (VEmax), tidal volume (VTmax), breathing frequency (fmax), inspiratory and expiratory times (tImax and tEmax), total duration of respiratory cycle (tTOTmax), mean inspiratory flow (VT/tImax), and inspiration fraction (tI/tTOTmax) were measured at VO2max. A power function was calculated between anthropometric characteristics and ventilatory variables to determine the allometric constants. The results showed firstly, that VEmax, VTmax, tImax, tEmax, tTOTmax, and VT/tImax increased with age and anthropometric characteristics (P less than 0.001), fmax decreased (P less than 0.001), and tI/tTOTmax remained constant during growth; secondly that lean body mass explained the greatest percentage of variance of VEmax (62.1%), VTmax (76.8%), and VT/tImax (70.6%), while anthropometric characteristics explained a slight percentage of variance of fmax and timing; and thirdly that VEmax, VTmax, and VT/tImax normalized by lean body mass did not change significantly with age. We concluded that at VO2max there were marked changes in ventilation and breathing pattern with growth. The changes in VEmax, VTmax, and VT/tImax were strongly related to the changes in lean body mass.  相似文献   

14.
Simultaneous measurements of water velocity in the buccal chamber, and buccal and opercular hydrostatic pressure of carp have revealed surprisingly high water velocities. The high flow velocities mean that, at times, the kinetic energy of flow makes a substantial contribution to the total fluid energy. This suggests that there may be unequal distribution of hydrostatic pressures within the buccal chamber. Anatomical examinations showed that fluid channels in the buccal chamber and gill raker sieve are complex and can be expected to vary spatially and temporally throughout the respiratory cycle. It appears that there is a potential for error in many of the previous analyses of 'gill resistance and energetics of fish breathing based solely on hydrostatic pressure measurements and the simplifying assumption of steady-state conditions.  相似文献   

15.
A modified heart-lung preparation of the rat, which permits measuring systolic and diastolic coronary flow separately and enables coronary compliance to be evaluated, is described. The systemic circulation was substituted by a shunt circuit, and the elastic properties of the arterial tree were mimicked by a rubber balloon. Systolic and diastolic coronary flow was evaluated from the pulmonary and aortic flow signal. Integrated phasic pulmonary flow represented right ventricular stroke volume. Integrated phasic systolic aortic flow represented left ventricular stroke volume minus that volume flowing into the coronary arteries during systole, because the aortic flow probe had to be inserted distal to the origin of the coronary vessels. Because right and left ventricular stroke volume was identical under steady-state conditions, the difference between systolic pulmonary and systolic aortic flow resulted in systolic coronary flow. Diastolic coronary flow was measured by means of the retrograde flow through the aortic flow probe. Coronary compliance was calculated according to Frank's windkessel model from coronary resistance and from central diastolic aortic pressure, which decayed exponentially after switching out the rubber balloon and the shunt circuit. It could be shown that the proportion of systolic to diastolic coronary flow depends on coronary compliance.  相似文献   

16.
Airway anesthesia with aerosolized lidocaine has been associated with an increase in minute ventilation (VE) during CO2 inhalation. The increase in VE may be due to increased neuromuscular output or decreased mechanical load on breathing. To evaluate this we measured VE, breathing pattern, mouth occlusion pressure, and lung mechanics in 20 normal subjects during room-air breathing and then inhalation of 6% CO2-94% O2, before and after airway anesthesia. Measurements of lung mechanics included whole-lung resistance, dynamic and static compliance, and functional residual capacity. Airway anesthesia had no detectable effect on any measurements during room-air breathing. During CO2 inhalation, airway anesthesia produced increases in VE and mean inspiratory flow rate (VT/TI) and more negative inspiratory pleural pressure but had no detectable effect on lung mechanics or mouth occlusion pressure. Pleural pressure was more negative during the latter 25% of inspiration. We concluded that airway receptors accessible to airway anesthesia play a role in determining neuromuscular output during CO2 inhalation.  相似文献   

17.
Regulation of end-expiratory lung volume during sleep in premature infants   总被引:1,自引:0,他引:1  
To investigate the regulation of end-expiratory lung volume (EEV) in premature infants, we recorded airflow, tidal volume, diaphragm electromyogram (EMG), and chest wall displacement during sleep. In quiet sleep, EEV during breathing was 10.8 +/- 3.6 (SD) ml greater than the minimum volume reached during unobstructed apneas. In active sleep, no decrease in EEV was observed during 28 of 35 unobstructed apneas. Breaths during quiet sleep had a variable extent of expiratory airflow retardation (braking), and inspiratory interruption occurred at substantial expiratory flow rates. During active sleep, the expiratory flow-volume curve was nearly linear, proceeding nearly to the volume axis at zero flow, and diaphragm EMG activity terminated near the peak of mechanical inspiration. Expiratory duration (TE) and inspiratory duration (TI) were significantly shortened in quiet sleep vs. active sleep although tidal volume was not significantly different. In quiet sleep, diaphragmatic braking activity and shortened TE combined to maintain EEV during breathing substantially above relaxation volume. In active sleep, reduced expiratory braking and prolongation of TE resulted in an EEV that was close to relaxation volume. We conclude that breathing strategy to regulate EEV in premature infants appears to be strongly influenced by sleep state.  相似文献   

18.
To assess the mechanical role of the expiratory musculature during eupnea, we recorded the electromyographic (EMG) activity of the triangularis sterni, the external oblique, and the transversus abdominis in eight supine lightly anesthetized dogs and have measured the volume generated by the phasic activation of the expiratory muscles. Activation of the expiratory muscles was invariably associated with a decrease in lung volume below the relaxed position of the respiratory system, a volume equal to 41.3 +/- 8.4 ml. This volume represented roughly 20% of tidal volume generated during spontaneous breathing. The fractional expiratory contribution to the tidal volume was unrelated to the size of the animal. Traction on the forelimbs (limb extension), however, tended to enhance the phasic expiratory activation of both the triangularis sterni and the transversus abdominis in the majority of animals. Moreover, after limb extension, the fractional contribution of tidal volume attributed to the phasic activation of the expiratory muscles increased in all but one animal. During spontaneous breathing with the forelimbs extended, roughly 25% of tidal volume was found to be due directly to phasic expiratory muscle contraction. The present observations firmly establish that in supine lightly anesthetized dogs breathing at rest the expiratory component of tidal volume represents a substantial contribution.  相似文献   

19.
The usual method of measuring density dependence of maximum expiratory flows is superimposition at total lung capacity or residual volume of maximum expiratory flow volume (MEFV) curves obtained breathing air and a mixture of 80% He plus 20% O2 (HeO2). A major problem with this technique is the large variability in results, which has been thought to be due to errors in matching lung volumes on both gases. Accordingly, we obtained MEFV curves breathing air and HeO2 using a bag-in-the-box system so that the curves breathing the two gas mixtures could be directly superimposed without removing the mouthpiece (isovolume). Ten healthy, nonsmoking subjects performed MEFV curves on each gas mixture for six consecutive experiments. We compared the increase in flow at 50% of vital capacity (delta Vmax50) and volume of isoflow (Viso) by superimposing and matching the MEFV curves at total lung capacity, at residual volume, and using the isovolume method. The variability of each method was assessed by the mean intersubject and intrasubject coefficients of variation. In all subjects, the mean delta Vmax50 and Viso as well as their corresponding coefficients of variation were not significantly different among the three methods. We conclude that, in healthy nonsmoking young adults, the method chosen for superimposing and matching MEFV curves has no effect on the variability of delta Vmax50 and Viso.  相似文献   

20.
The effective elastance of the respiratory system (which has been previously shown to provide an index of the ability of the respiratory musculature to compensate rapidly for transient mechanical ventilatory loads) was measured in six hypoxic dogs to determine whether hypoxia hindered immediate load-compensatory mechanisms. The effective elastance value was computed from measurements of control tidal volume and the pressure developed at the airway opening during the first inspiratory effort following airway occlusion at FRC. The mean effective elastance was 197 cmH2O/l while the animals were breathing room air and did not change significantly when the animals were rendered hypoxic by reducing the inspired oxygen concentration, in five dogs, or by controlled hemorrhage, in two dogs. It was concluded that inasmuch as effective elastance measurements remain constant during hypoxia, the stability of ventilation is not significantly impaired in this situation.  相似文献   