首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The development of a multidimensional approach involving high-performance liquid chromatography (LC), ion mobility spectrometry (IMS) and tandem mass spectrometry is described for the analysis of complex peptide mixtures. In this approach, peptides are separated based on differences in their LC retention times and mobilities (as ions drift through He) prior to being introduced into a quadrupole/octopole/time-of-flight mass spectrometer. The initial LC separation and IMS dispersion of ions is used to label ions for subsequent fragmentation studies that are carried out for mixtures of ions. The approach is demonstrated by examining a mixture of peptides generated from tryptic digestion of 18 commercially available proteins. Current limitations of this initial study and potential advantages of the experimental approach are discussed.  相似文献   

2.
Today, 2D online or offline liquid chromatography/mass spectrometry is state of the art for the identification of proteins from complex proteome samples in many laboratories. Both 2D liquid chromatography methods use two orthogonal liquid chromatography separation techniques. The most commonly used techniques are strong cation exchange chromatography for the first dimension and reversed phase separation for the second dimension. In order to improve sensitivity the reversed phase separation is usually performed in the nanoflow scale and mass spectrometry is used as the final detection method. The high-performance liquid chromatography techniques complement the 2D-gel techniques supporting their weaknesses. This is especially true for the gel separation of hydrophobic membrane proteins, which play an important role in living cells as well as being important targets for future pharmaceutical drugs.  相似文献   

3.
Today, 2D online or offline liquid chromatography/mass spectrometry is state of the art for the identification of proteins from complex proteome samples in many laboratories. Both 2D liquid chromatography methods use two orthogonal liquid chromatography separation techniques. The most commonly used techniques are strong cation exchange chromatography for the first dimension and reversed phase separation for the second dimension. In order to improve sensitivity the reversed phase separation is usually performed in the nanoflow scale and mass spectrometry is used as the final detection method. The high-performance liquid chromatography techniques complement the 2D-gel techniques supporting their weaknesses. This is especially true for the gel separation of hydrophobic membrane proteins, which play an important role in living cells as well as being important targets for future pharmaceutical drugs.  相似文献   

4.
We have expanded our recent on-line LC-MS platform for large peptide analysis to combine collision-induced dissociation (CID), electron-transfer dissociation (ETD), and CID of an isolated charge-reduced (CRCID) species derived from ETD to determine sites of phosphorylation and glycosylation modifications, as well as the sequence of large peptide fragments (i.e., 2000-10,000 Da) from complex proteins, such as beta-casein, epidermal growth factor receptor (EGFR), and tissue plasminogen activator (t-PA) at the low femtomol level. The incorporation of an additional CID activation step for a charge-reduced species, isolated from ETD fragment ions, improved ETD fragmentation when precursor ions with high m/z (approximately >1000) were automatically selected for fragmentation. Specifically, the identification of the exact phosphorylation sites was strengthened by the extensive coverage of the peptide sequence with a near-continuous product ion series. The identification of N-linked glycosylation sites in EGFR and an O-linked glycosylation site in t-PA were also improved through the enhanced identification of the peptide backbone sequence of the glycosylated precursors. The new strategy is a good starting survey scan to characterize enzymatic peptide mixtures over a broad range of masses using LC-MS with data-dependent acquisition, as the three activation steps can provide complementary information to each other. In general, large peptides can be extensively characterized by the ETD and CRCID steps, including sites of modification from the generated, near-continuous product ion series, supplemented by the CID-MS2 step. At the same time, small peptides (e.g., 相似文献   

5.
We have investigated the use of a variety of different techniques to identify as many proteins as possible in a yeast lysate, with the aim of investigating the overlap and complementarity of data from different approaches. A standard lysate was prepared from log phase yeast (Saccharomyces cerevisiae). This was then subjected to analysis via five different approaches aimed at identifying as many proteins as possible using an ion trap mass spectrometer. The total number of non-redundant protein identifications from each experiment was: 524 proteins by 2-D (SCX/C18) nanoflow liquid chromatography-liquid chromatography tandem mass spectrometry (nanoLC-LC MS/MS (MudPIT)); 381 proteins by nanoLC-MS/MS with gas phase fractionation by mass range selection; 390 proteins by nanoLC-MS/MS with gas phase fractionation by ion abundance selection; 898 proteins by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) separation of proteins, in-gel digestion, and nanoLC-MS/MS of gel slices; and 422 proteins by isoelectric focusing of proteins, in-gel digestion and nanoLC-MS/MS of gel slices. The total number of non-redundant protein identifications in the five experiments was 1204. Combining only the two best experiments, the SDS-PAGE gel slices and the Mudpit, produces 1024 proteins identified, more than 85% of the total. Clearly, combining a Mudpit analysis with an SDS-PAGE gel slice experiment gives the greatest amount of protein identification information from a limited amount of sample.  相似文献   

6.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is an atmospheric pressure ion mobility technique that separates gas-phase ions by their behavior in strong and weak electric fields. FAIMS is easily interfaced with electrospray ionization and has been implemented as an additional separation mode between liquid chromatography (LC) and mass spectrometry (MS) in proteomic studies. FAIMS separation is orthogonal to both LC and MS and is used as a means of on-line fractionation to improve the detection of peptides in complex samples. FAIMS improves dynamic range and concomitantly the detection limits of ions by filtering out chemical noise. FAIMS can also be used to remove interfering ion species and to select peptide charge states optimal for identification by tandem MS. Here, the authors review recent developments in LC-FAIMS-MS and its application to MS-based proteomics.  相似文献   

7.
Covalent addition of nitric oxide (NO) to Cys-sulfur in proteins, or S-nitrosylation, plays pervasive roles in the physiological and pathophysiological modulation of mammalian protein functions. Knowledge of the specific protein Cys residues that undergo NO addition in different biological settings is fundamental to understanding NO-mediated signal transduction. Here, we describe in detail an MS-based proteomic protocol for facile, high-throughput and unbiased discovery of SNO-Cys residues in proteins from complex biological samples. The approach, termed SNOSID (SNO-Cys site identification), can be used to identify endogenous and chemically induced S-nitrosylation sites in proteins from tissues or cells. Identified SNO-Cys sites may provide insights into novel mechanisms and proteins that mediate NO bioactivities in health and disease. SNOSID builds on the biotin-switch method for covalent addition of disulfide-linked biotin at S-nitrosylation sites on proteins. Biotinylated proteins are then subjected to trypsinolysis and the resulting biotin-tagged peptides are affinity-captured on streptavidin-agarose. After selective elution with beta-mercaptoethanol, the peptides are sequenced using nanoflow liquid chromatography tandem mass spectrometry (nLC-MS/MS). Validation that identified peptide ions as originating from authentic NO-Cys-containing precursor proteins can be provided by establishing that these peptide ions are absent from control samples where S-NO bonds were subjected to prior photolysis, using a UV transilluminator. The protocol requires approximately 2 days for sample processing, including the incubation time for proteolysis. An additional 1-2 days is needed for sample analysis by nLC-MS/MS and data analysis/interpretation.  相似文献   

8.
A technique that combines ion mobility spectrometry (IMS) with reversed-phase liquid chromatography (LC), collision-induced dissociation (CID) and mass spectrometry (MS) has been developed. The approach is described as a high throughput means of analysing complex mixtures of peptides that arise from enzymatic digestion of protein mixtures. In this approach, peptides are separated by LC and, as they elute from the column, they are introduced into the gas phase and ionised by electrospray ionisation. The beam of ions is accumulated in an ion trap and then the concentrated ion packet is injected into a drift tube where the ions are separated again in the gas phase by IMS, a technique that differentiates ions based on their mobilities through a buffer gas. As ions exit the drift tube, they can be subjected to collisional activation to produce fragments prior to being introduced into a mass spectrometer for detection. The IMS separation can be carried out in only a few milliseconds and offers a number of advantages compared with LC-MS alone. An example of a single 21-minute LC-IMS-(CID)-MS analysis of the human plasma proteome reveals approximately 20,000 parent ions and approximately 600,000 fragment ions and evidence for 227 unique protein assignments.  相似文献   

9.
Multi-dimensional liquid phase based separations in proteomics   总被引:7,自引:0,他引:7  
This review covers recent developments towards the implementation of multi-dimensional (MuD) liquid phase based systems for proteome investigations. Although two-dimensional polyacrylamide gel electrophoresis (2D-PAGE) has been used as a standard approach in proteomics, its drawbacks including the limited dynamic range and molecular mass range, together with lack of on-line integration with biological mass spectrometery (Bio-MS) have limited its widespread use and applications in proteomics. In the meantime, various liquid-phase based multi-dimensional separation techniques have been explored. Especially, with the emergence of the combination of nanoflow capillary high-performance liquid chromatography (cHPLC) and Bio-MS, attention is again refocused on utilizing multi-dimensional liquid-phase based separation of proteins. Some remarkable applications of on-line analysis of intact proteins and on-column digested proteins, and the emergence of approaches such as multiple HPLC-electrospray ionization tandem MS and capillary array electrophoresis-matrix assisted laser desorption ionization MS, have stimulated thinking towards developing a automated multi-dimensional system (MuDSy) that integrates liquid phase based separation, digestion and identification of proteins in complex biological mixtures.  相似文献   

10.
Liu H  Lin D  Yates JR 《BioTechniques》2002,32(4):898, 900, 902 passim
Proteomics is the study of all or part of the protein complement of genes in an organism, often involving the analysis of complex protein/peptide samples. Such complex samples are beyond the separation capacity of 1-D separation techniques. This review describes several multidimensional separations for proteins and peptides. First, several variants of 2-D liquid chromatography (2DLC) are reviewed, including coupled size exclusion-reversed phase, ion exchange-reversed phase, and reversed phase-reversed phase chromatography. Second, we describe coupled liquid chromatography and capillary electrophoresis methods. Finally, a multidimensional protein identification technique (MudPIT) is explained in detail. Each of the described techniques has a much higher separation capacity than 1-D methods and can potentially be automated for high-throughput experiments. In particular, MudPIT takes advantage of both the high separation capacity of 2DLC and the powerful peptide characterization ability of tandem mass spectrometry to analyze complex protein samples. Additional applications and developments of multidimensional liquid separations for proteomics are expected in the future.  相似文献   

11.
Reversed-phase liquid chromatography interfaced to electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) allows analysis of very complex peptide mixtures at great sensitivity, but it can be very time-consuming, typically using 60 min, or more, per sample analysis. We recently introduced the isocratic solid phase extraction-liquid chromatography (SPE-LC) technology for rapid separation (~8 min) of simple peptide samples. We now extend these studies to demonstrate the potential of SPE-LC separation in combination with a hybrid linear ion trap-Orbitrap tandem mass spectrometer for efficient analysis of peptide samples in proteomics research. The system performance of SPE-LC-MS/MS was evaluated in terms of sensitivity and efficiency for the analysis of tryptic peptide digests obtained from samples consisting of up to 12 standard proteins. The practical utility of the analytical setup was demonstrated by the analysis of <15 microg depleted human serum proteome by a combination of SDS-PAGE and SPE-LC-MS/MS. A total of 88 unique gene products spanning 3 orders of magnitude in serum protein concentration were identified using stringent database search criteria.  相似文献   

12.
A two-dimensional (2D) separation method was used to decrease sample complexity in analysis of tryptic peptides from glomerular membrane proteins by tandem mass spectrometry (MS/MS). The first dimension was carried out by electrocapture (EC), which fractionates peptides according to electrophoretic mobility. The second dimension was reverse-phase liquid chromatography (RP-LC), in which EC fractions were further separated and analyzed online by MS/MS. Using this methodology, we now identify 102 glomerular proteins (57 membrane proteins). Many peptides were possible to observe and select for MS/MS only using the 2D approach. Others were detectable in both one-dimensional (1D, without the EC step) and 2D experiments but were selectable for sequence analysis only from the 2D separations because the decrease in complexity then gives time for the mass analyzer to select the peptide and switch to the MS/MS mode. A minority of the peptides were detectable only in the 1D mode (presumably because of handling losses), but at the end this did not decrease the number of proteins identified by the 2D separation. After a database search, the combination of EC and RP-LC MS/MS versus a 1D RP-LC MS/MS separation resulted in a threefold increase in the number of proteins identified and improved the sequence coverage in the identifications, bringing our proteome-identified glomerular proteins to 282.  相似文献   

13.
Extensive site-specific glycosylation analysis of individual glycoproteins is difficult due to the nature and complexity of glycosylation in proteins. In protein mixtures, these analyses are even more difficult. We present an approach combining nonspecific protease digestion, nanoflow liquid chromatography, and tandem mass spectrometry (MS/MS) aimed at comprehensive site-specific glycosylation analysis in protein mixtures. The strategy described herein involves the analysis of a complex mixture of glycopeptides generated from immobilized-Pronase digestion of a cocktail of glycoproteins consisting of bovine lactoferrin, kappa casein, and bovine fetuin using nanoflow liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (nano-LC-Q-TOF MS). The resulting glycopeptides were chromatographically separated on a micro fluidic chip packed with porous graphitized carbon and analyzed via MS and MS/MS analyses. In all, 233 glycopeptides (identified based on composition and including isomers) corresponding to 18 glycosites were observed and determined in a single mixture. The glycopeptides were a mixture of N-linked glycopeptides (containing high mannose, complex and hybrid glycans) and O-linked glycopeptides (mostly sialylated). Results from this study were comprehensive as detailed glycan microheterogeneity information was obtained. This approach presents a platform to simultaneously characterize N- and O-glycosites in the same mixture with extensive site heterogeneity.  相似文献   

14.
采用自动在线纳流多维液相色谱 串联质谱联用的方法分离和鉴定蔗糖密度梯度离心法分离和富集的小鼠肝脏质膜蛋白质 .以强阳离子交换柱为第一相 ,反相柱为第二相 ,在两相之间连接一预柱脱盐和浓缩肽段 .用含去污剂的溶剂提取细胞质膜中的蛋白质 ,获得的质膜蛋白质经酶解和适当的酸化后通过离子交换柱吸附 ,分别用 10个不同浓度的乙酸铵盐溶液进行分段洗脱 .洗脱物经预柱脱盐和浓缩后进入毛细管反相柱进行反相分离 ,分离后的肽段直接进入质谱仪离子源进行一级和二级质谱分析 .质谱仪采得的数据经计算机处理后用Mascot软件进行蛋白质数据库搜寻 ,共鉴定出 12 6种蛋白质 ,其中 4 1种为膜蛋白 ,包括与膜相关的蛋白质和具有多个跨膜区的整合膜蛋白 ,为建立质膜蛋白质组学研究的适宜方法和质膜蛋白质数据库提供了有价值的基础性研究资料 .  相似文献   

15.
The proteins secreted by prostate cancer cells (PC3(AR)6) were separated by strong anion exchange chromatography, digested with trypsin and analyzed by unbiased liquid chromatography tandem mass spectrometry with an ion trap. The spectra were matched to peptides within proteins using a goodness of fit algorithm that showed a low false positive rate. The parent ions for MS/MS were randomly and independently sampled from a log-normal population and therefore could be analyzed by ANOVA. Normal distribution analysis confirmed that the parent and fragment ion intensity distributions were sampled over 99.9% of their range that was above the background noise. Arranging the ion intensity data with the identified peptide and protein sequences in structured query language (SQL) permitted the quantification of ion intensity across treatments, proteins and peptides. The intensity of 101,905 fragment ions from 1421 peptide precursors of 583 peptides from 233 proteins separated over 11 sample treatments were computed together in one ANOVA model using the statistical analysis system (SAS) prior to Tukey-Kramer honestly significant difference (HSD) testing. Thus complex mixtures of proteins were identified and quantified with a high degree of confidence using an ion trap without isotopic labels, multivariate analysis or comparing chromatographic retention times.  相似文献   

16.
Mass spectrometry has become an indispensable tool in identifying post-translationally modified proteins, but multiple peptide mass-mapping/peptide-sequencing experiments are required to answer questions involving the site and type of modification present. Here, we apply ion mobility-mass spectrometry (IM-MS), a high-throughput analysis method having high selectivity and sensitivity, to the challenge of identifying phosphorylated peptides. Ion mobility separation is based on the collision cross-section of the ion. Phosphorylation can result in a conformational change in gas-phase peptide ions, which can be detected by IM. To demonstrate this point, a peptide mixture containing a variety of peptide sequences is examined with IM-MS and molecular dynamics calculations. During the course of these studies, two classes of phosphopeptide were identified: (i) phosphorylated peptide ions that have conformers that differ from the nonphosphorylated ion and (ii) phosphorylated peptide ions that have conformations that are very similar to the nonphosphorylated peptide. The utility of IM-MS peptide mass mapping for identifying both types of phosphorylated peptides is discussed.  相似文献   

17.
It was demonstrated that a shotgun approach can be utilized for the characterization of phospholipids (PLs) extracted from mouse liver and brain by using nanoflow reversed phase liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS). In this study, a dual scan method was introduced for the high throughput analysis of complex PL mixtures. Two consecutive LC-ESI-MS-MS runs were made in positive ion mode (for phosphatidylcholines (PCs) and phosphatidylethanolamines (PEs)) first followed by analysis in negative ion mode (for phosphatidylserine (PSs) and phosphatidylinositol (PIs)) using the same binary gradient elution with and without adding formic acid, respectively. The separation of the PLs was carried out using a home made pull tip capillary column (C18) with an end frit. The MS analysis of the eluted PL molecules was performed with a precursor scan followed by a data dependent MS-MS scan. The developed dual scan method was tested with the extracts of PCs and PIs mixtures from soybean, PEs from Escherichia coli, and PSs from bovine brain. It was further applied for the characterization of intact PL samples that were extracted from both mouse liver and mouse brain in the laboratory, and resulted in the identification of 90 and 80 PL species, respectively.  相似文献   

18.
Differential, functional, and mapping proteomic analyses of complex biological mixtures suffer from a lack of component resolution. Here we describe the application of ion mobility-mass spectrometry (IMS-MS) to this problem. With this approach, components that are separated by liquid chromatography are dispersed based on differences in their mobilities through a buffer gas prior to being analyzed by MS. The inclusion of the gas-phase dispersion provides more than an order of magnitude enhancement in component resolution at no cost to data acquisition time. Additionally, the mobility separation often removes high-abundance species from spectral regions containing low-abundance species, effectively increasing measurement sensitivity and dynamic range. Finally, collision-induced dissociation of all ions can be recorded in a single experimental sequence while conventional MS methods sequentially select precursors. The approach is demonstrated in a single, rapid (3.3 h) analysis of a plasma digest sample where abundant proteins have not been removed. Protein database searches have yielded 731 high confidence peptide assignments corresponding to 438 unique proteins. Results have been compiled into an initial analytical map to be used -after further augmentation and refinement- for comparative plasma profiling studies.  相似文献   

19.
The potential of drift tube ion mobility (IM) spectrometry in combination with high performance liquid chromatography (LC) and mass spectrometry (MS) for the metabonomic analysis of rat urine is reported. The combined LC-IM-MS approach using quadrupole/time-of-flight mass spectrometry with electrospray ionisation, uses gas-phase analyte characterisation based on both mass-to-charge (m/z) ratio and relative gas-phase mobility (drift time) following LC separation. The technique allowed the acquisition of nested data sets, with mass spectra acquired at regular intervals (65 micros) during each IMS separation (approximately 13 ms) and several IMS spectra acquired during the elution of a single LC peak, without increasing the overall analysis time compared to LC-MS. Preliminary results indicate that spectral quality is improved when using LC-IM-MS, compared to direct injection IM-MS, for which significant ion suppression effects were observed in the electrospray ion source. The use of reversed-phase LC employing fast gradient elution reduced sample preparation to a minimum, whilst maintaining the potential for high throughput analysis. Data mining allowed information on specific analytes to be extracted from the complex metabonomic data set. LC-IM-MS based approaches may have a useful role in metabonomic analyses by introducing an additional discriminatory dimension of ion mobility (drift time).  相似文献   

20.
Advances in the field of proteomics depend upon the development of high-throughput separation methods. Ion mobility-mass spectrometry is a fast separation method (separations on the millisecond time-scale), which has potential for peptide complex mixture analysis. Possible disadvantages of this technique center around the lack of orthogonality between separation based on ion mobility and separation based on mass. In order to examine the utility of ion mobility-mass spectrometry, the peak capacity (phi) of the technique was estimated by subjecting a large dataset of peptides to linear regression analysis to determine an average trend for tryptic peptides. This trend-line, along with the deviation from a linear relationship observed for this dataset, was used to define the separation space for ion mobility-mass spectrometry. Using the maximum deviation found in the dataset (+/-11%) the peak capacity of ion mobility-mass spectrometry is approximately 2600 peptides. These results are discussed in light of other factors that may increase the peak capacity of ion mobility-mass spectrometry (i.e. multiple trends in the data resulting from multiple classes of compounds present in a sample) and current liquid chromatography approaches to complex peptide mixture analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号