Objective

To determine whether the presence of chronic obstructive lung disease (COPD) and reduction of lung function parameters were predictors of mortality in a cohort.

Materials/Patients and Methods

Population based cohorts were followed in Montevideo, Santiago and Sao Paulo during 5, 6 and 9 years, respectively. Outcomes included all-cause, cardiovascular, respiratory and cancer mortality; exposures were COPD, forced expiratory volume in one second (FEV1) and forced vital capacity (FVC). Cox regression was used for analyses. Sensitivity, specificity, positive and negative predictive values, receiver operator characteristics curves and Youden''s index were calculated.

Results

Main causes of death were cardiovascular, respiratory and cancer. Baseline COPD was associated with overall mortality (HR = 1.43 for FEV1/FVC<LLN; 2.01 for GOLD 2-4; 1.46 for GOLD 1-4; 1.50 for FEV1/FEV6 <LLN). For cardiovascular mortality, significant associations were found with GOLD 2-4 (HR = 2.68) and with GOLD 1-4 (HR = 1.78) for both genders together (not among women). Low FEV1 was risk for overall and respiratory mortality (both genders combined). FVC was not associated with overall mortality. For most COPD criteria sensitivity was low and specificity high. The area under the curve for FEV1 was greater than for FVC for overall and cardiovascular mortality.

Answer to the Question

COPD and low FEV1 are important predictors for overall and cardiovascular mortality in Latin America.  相似文献   

2.

Background

Specific occupations are associated with adverse respiratory health. Inhalation exposures encountered in these jobs may place workers at risk of new-onset respiratory disease.

Methods

We analyzed data from 8,967 participants from the Atherosclerosis Risk in Communities (ARIC) study, a longitudinal cohort study. Participants included in this analysis were free of chronic cough and phlegm, wheezing, asthma, chronic bronchitis, emphysema, and other chronic lung conditions at the baseline examination, when they were aged 45-64 years. Using data collected in the baseline and first follow-up examination, we evaluated associations between occupation and the three-year incidence of cough, phlegm, wheezing, and airway obstruction and changes in forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) measured by spirometry. All associations were adjusted for age, cigarettes per day, race, smoking status, and study center.

Results

During the approximately three-year follow-up, the percentage of participants developing chronic cough was 3%; chronic phlegm, 3%; wheezing, 3%; and airway obstruction, defined as FEV1 < lower limit of normal (LLN) and FEV1/FVC < LLN, 2%. The average annual declines in FEV1 and FVC were 56 mL and 66 mL, respectively, among men and 40 mL and 52 mL, respectively, among women. Relative to a referent category of managerial and administrative support occupations, elevated risks of new-onset chronic cough and chronic phlegm were observed for mechanics and repairers (chronic cough: RR: 1.81, 95% CI: 1.02, 3.21; chronic phlegm: RR: 2.10, 95% CI: 1.23, 3.57) and cleaning and building service workers (chronic cough: RR: 1.85, 95% CI: 1.01, 3.37; chronic phlegm: RR: 2.28, 95% CI: 1.27, 4.08). Despite the elevated risk of new-onset symptoms, employment in cleaning and building services was associated with attenuated lung function decline, particularly among men, who averaged annual declines in FEV1 and FVC of 14 mL and 23 mL, respectively, less than the declines observed in the referent population.

Conclusions

Employment in mechanic and repair jobs and cleaning and building service occupations are associated with increased incidence of respiratory symptoms. Specific occupations affect the respiratory health of adults without pre-existing respiratory health symptoms and conditions, though long-term health consequences of inhalation exposures in these jobs remain largely unexplored.  相似文献   

3.

Background

Desmosine and Isodesmosine (D/I) are cross-linking amino acids which are present only in mature elastin. Changes in their concentration in body fluids indicate changes in elastin degradation and can be a reflection of tissue elastase activity. This study was undertaken to determine whether continuous therapy with the long-acting bronchodilator Tiotropium bromide (TTP) could result in reductions in D/I as measured by mass spectrometry in plasma, urine and sputum.

Methods

Twelve not currently smoking patients with chronic obstructive pulmonary disease (COPD), never on TTP, were selected for study. Levels of D/I, along with measurements of FVC, FEV1 and FEV1/FVC. were determined before starting TTP daily, and then one and two months after.

Results

D/I decreased in plasma (10 of 12 patients), in sputum all (12 of 12), and in the percentage of free D/I in urine (10 of 12). Most patients showed slight increases in FVC and FEV1 percent predicted over two months.

Conclusion

The results are consistent with an effect of prolonged bronchodilitation by anti-cholinergic blockade to also result in reduced lung elastin degradation.  相似文献   

4.

Background

Prevalence and risk factors for respiratory symptoms and airway obstruction in HIV-infected subjects in the era of highly active antiretroviral therapy (HAART) are unknown. We evaluated respiratory symptoms and measured airway obstruction to identify the impact of HAART and other risk factors on respiratory symptoms and pulmonary function.

Methodology/Principal Findings

Two hundred thirty-four HIV-infected adults without acute respiratory symptoms were recruited from an HIV clinic. All subjects were interviewed and performed spirometry. Multivariate linear and logistic regressions were performed to determine predictors of respiratory symptoms, forced expiratory volume in one second (FEV1) percent predicted, and FEV1/forced vital capacity (FEV1/FVC). Thirty-one percent of subjects reported at least one respiratory symptom. Smoking status (current or former versus never) (odds ratio [OR] = 2.7, 95% confidence interval [CI] = 1.41–5.22, p = 0.003), higher log plasma HIV viral levels (OR = 1.12, 95%CI = 1.02–1.24, p = 0.02), and lower FEV1/FVC (OR = 1.06 for every 0.01 decrease in FEV1/FVC, 95%CI = 1.02–1.14, p = 0.001) were independent predictors of respiratory symptoms. Age (p = 0.04), pack-year smoking history (p<0.001), previous bacterial pneumonia (p = 0.007), and HAART use (p = 0.04) were independent predictors of decreased FEV1/FVC.

Conclusions/Significance

Respiratory symptoms remain common in HIV-infected subjects, especially in those with a smoking history. Subjects who were older, had a greater pack-year history of smoking, or previous bacterial pneumonia had lower FEV1/FVC ratios. Interestingly, use of HAART was independently associated with a decreased FEV1/FVC, possibly secondary to an immune response to subclinical infections, increased autoimmunity, or other factors associated with HAART use.  相似文献   

5.

Introduction

FEF25-75 is one of the standard results provided in spirometry reports; however, in adult asthmatics there is limited information on how this physiological measure relates to clinical or biological outcomes independently of the FEV1 or the FEV1/FVC ratio.

Purpose

To determine the association between Hankinson’s percent-predicted FEF25-75 (FEF25-75%) levels with changes in healthcare utilization, respiratory symptom frequency, and biomarkers of distal airway inflammation.

Methods

In participants enrolled in the Severe Asthma Research Program 1–2, we compared outcomes across FEF25-75% quartiles. Multivariable analyses were done to avoid confounding by demographic characteristics, FEV1, and the FEV1/FVC ratio. In a sensitivity analysis, we also compared outcomes across participants with FEF25-75% below the lower limit of normal (LLN) and FEV1/FVC above LLN.

Results

Subjects in the lowest FEF25-75% quartile had greater rates of healthcare utilization and higher exhaled nitric oxide and sputum eosinophils. In multivariable analysis, being in the lowest FEF25-75% quartile remained significantly associated with nocturnal symptoms (OR 3.0 [95%CI 1.3–6.9]), persistent symptoms (OR 3.3 [95%CI 1–11], ICU admission for asthma (3.7 [1.3–10.8]) and blood eosinophil % (0.18 [0.07, 0.29]). In the sensitivity analysis, those with FEF25-75% <LLN had significantly more nocturnal and persistent symptoms, emergency room visits, higher serum eosinophil levels and increased methacholine responsiveness.

Conclusions

After controlling for demographic variables, FEV1 and FEV1/FVC, a reduced FEF25-75% is independently associated with previous ICU admission, persistent symptoms, nocturnal symptoms, blood eosinophilia and bronchial hyperreactivity. This suggests that in some asthmatics, a reduced FEF25-75% is an independent biomarker for more severe asthma.  相似文献   

6.

Purpose

We aimed to study the association between lung function decline and quantitative computed tomography (CT) air trapping.

Materials and Methods

Current and former heavy smokers in a lung cancer screening trial underwent volumetric low-dose CT in inspiration and expiration. Spirometry was obtained at baseline and after 3 years. The expiratory to inspiratory ratio of mean lung density (E/I-ratioMLD) was used to quantify air trapping. CT emphysema was defined as voxels in inspiratory CT below −950 Hounsfield Unit. Linear mixed modeling was used to determine the association between CT air trapping and lung function.

Results

We included 985 subjects with a mean age of 61.3 years. Independent of CT emphysema, CT air trapping was significantly associated with a reduction in forced expiratory volume in one second (FEV1) and the ratio of FEV1 over the forced vital capacity (FEV1/FVC); FEV1 declines with 33 mL per percent increase in CT air trapping, while FEV1/FVC declines 0.58% per percent increase (both p<0.001). CT air trapping further elicits accelerated loss of FEV1/FVC (additional 0.24% reduction per percent increase; p = 0.014).

Conclusion

In a lung cancer screening cohort, quantitatively assessed air trapping on low-dose CT is independently associated with reduced lung function and accelerated decline of FEV1/FVC.  相似文献   

7.

QUESTION

A 6-second spirometry test is easier than full exhalations. We compared the reliability of the ratio of the Forced expiratory volume in 1 second/Forced expiratory volume in 6 seconds (FEV1/FEV6) to the ratio of the FEV1/Forced vital capacity (FEV1/FVC) for the detection of airway obstruction.

METHODS

The PLATINO population-based survey in individuals aged 40 years and over designed to estimate the prevalence of post-Bronchodilator airway obstruction repeated for the same study participants after 5–9 years in three Latin-American cities.

RESULTS

Using the FEV1/FVC<Lower limit of normal (LLN) index, COPD prevalence apparently changed from 9.8 to 13.2% in Montevideo, from 9.7 to 6.0% in São Paulo and from 8.5 to 6.6% in Santiago, despite only slight declines in smoking prevalence (from 30.8% to 24.3%). These changes were associated with differences in Forced expiratory time (FET) between the two surveys. In contrast, by using the FEV1/FEV6 to define airway obstruction, the changes in prevalence were smaller: 9.7 to 10.6% in Montevideo, 8.6 to 9.0% in São Paulo, and 7.5 to 7.9% in Santiago. Changes in the prevalence of COPD with criteria based on FEV1/FVC correlated strongly with changes in the FET of the tests (R2 0.92) unlike the prevalence based on a low FEV1/FEV6 (R2 = 0.40).

CONCLUSION

The FEV1/FEV6 is a more reliable index than FEV1/FVC because FVC varies with the duration of the forced exhalation. Reporting FET and FEV1/FEV6<LLN helps to understand differences in prevalence of COPD obtained from FEV1/FVC-derived indices.  相似文献   

8.

Rationale

Bronchodilator responsiveness (BDR) is a common but variable phenomenon in COPD. The CT characteristics of airway dimensions that differentiate COPD subjects with BDR from those without BDR have not been well described. We aimed to assess airway dimensions in COPD subjects with and without BDR.

Methods

We analyzed subjects with GOLD 1–4 disease in the COPDGene® study who had CT airway analysis. We divided patients into two groups: BDR + (post bronchodilator ΔFEV1 ≥ 10%) and BDR-(post bronchodilator ΔFEV1 < 10%). The mean wall area percent (WA%) of six segmental bronchi in each subject was quantified using VIDA. Using 3D SLICER, airway wall thickness was also expressed as the square root wall area of an airway of 10 mm (Pi10) and 15 mm (Pi15) diameter. %Emphysema and %gas trapping were also calculated.

Results

2355 subjects in the BDR-group and 1306 in the BDR + group formed our analysis. The BDR + group had a greater Pi10, Pi15, and mean segmental WA% compared to the BDR-group. In multivariate logistic regression using gender, race, current smoking, history of asthma, %emphysema, %gas trapping, %predicted FEV1, and %predicted FVC, airway wall measures remained independent predictors of BDR. Using a threshold change in FEV1 ≥ 15% and FEV1 ≥ 12% and 200 mL to divide patients into groups, the results were similar.

Conclusion

BDR in COPD is independently associated with CT evidence of airway pathology. This study provides us with greater evidence of changes in lung structure that correlate with physiologic manifestations of airflow obstruction in COPD.  相似文献   

9.

Background

Dyspnea while performing the activities of daily living has been suggested to be a better measurement than peak dyspnea during exercise. Furthermore, the inspiratory capacity (IC) has been shown to be more closely related to exercise tolerance and dyspnea than the FEV1, because dynamic hyperinflation is the main cause of shortness of breath in patients with COPD. However, breathlessness during exercise is measured in most studies to evaluate this relationship.

Purpose

To evaluate the correlation between breathlessness during daily activities and airflow limitation or static hyperinflation in COPD.

Methods

We examined 167 consecutive outpatients with stable COPD. The Baseline Dyspnea Index (BDI) was used to evaluate dyspnea with activities of daily living. The relationship between the BDI score and the clinical measurements of pulmonary function was then investigated.

Results

The Spearman rank correlation coefficients (Rs) between the BDI score and the FEV1(L), FEV1(%pred) and FEV1/FVC were 0.60, 0.56 and 0.56, respectively. On the other hand, the BDI score also correlated with the IC, IC/predicted total lung capacity (TLC) and IC/TLC (Rs = 0.45, 0.46 and 0.47, respectively). Although all of the relationships studied were strongly correlated, the correlation coefficients were better between dyspnea and airflow limitation than between dyspnea and static hyperinflation. In stepwise multiple regression analyses, the BDI score was most significantly explained by the FEV1 (R2 = 26.2%) and the diffusion capacity for carbon monoxide (R2 = 14.4%) (Cumulative R2 = 40.6%). Static hyperinflation was not a significant factor for clinical dyspnea on the stepwise multiple regression analysis.

Conclusion

Both static hyperinflation and airflow limitation contributed greatly to dyspnea in COPD patients.  相似文献   

10.

Background

Non-protective work practices followed by farm workers during spraying of pesticides lead to occupational exposure among them.

Objective

This study is designed to explore the respiratory health and hematological profile of agricultural workers occupationally exposed to OP pesticides.

Materials and Methods

A cross sectional study was undertaken among 166 pesticide sprayers working in mango orchards of Lucknow district in North India compared with 77 controls to assess the respiratory illness, lung functions, cholinesterase levels and hematological profile. A questionnaire based survey and clinical examination for respiratory health were conducted among study subjects. Lung function test was conducted among study subjects by using spirometer. Cholinesterase level as biomarker of OP pesticides and hematological profile of study subjects were investigated in the laboratory by following the standard protocols.

Results

Overall respiratory morbidity observed among exposed subjects was 36.75%. Symptoms for respiratory illness like dry cough, productive cough, wheezing, irritation of throat and blood stained sputum were found to be significantly more (p<0.05) among pesticide sprayers than controls. Lung function parameters viz. PEFR, FEV1, %PEFR predicted, %FEV1 predicted and FEV1/FVC were found to be significantly decreased (p<0.05) among pesticide sprayers as compared to controls. Exposure wise distribution of respiratory illness and lung functions among pesticide sprayers show that the exposure duration significantly elevates (p<0.05) the respiratory problems and significantly decreases (p<0.001) lung functions among pesticide sprayers. Activities of acetylcholinesterase and butyrylcholinesterase were found to be significantly depleted (p<0.001) among pesticide sprayers as compared to controls which show the exposure of OP pesticides among them. The hematological profile viz. RBC, WBC, monocytes, neutrophils, MCV, MCH, MCHC and platelet count were significantly altered (p<0.001) in pesticide sprayers than controls.

Conclusion

This study shows that the unsafe occupational exposure of OP pesticides causes respiratory illness, decreased lung functions and hematological alterations among pesticide sprayers.  相似文献   

11.

Background

There is increasing evidence that structural lung changes may be present before the occurrence of airflow limitation as assessed by spirometry. This study investigated the prevalence of computed tomography (CT) quantified emphysema, airway wall thickening and gas trapping according to classification of airflow limitation (FEV1/FVC <70% and/or < the lower limit of normal (LLN)) in (heavy) smokers.

Methods

A total number of 1,140 male former and current smokers participating in a lung cancer screenings trial (NELSON) were included and underwent chest CT scanning and spirometry. Emphysema was quantified by the 15th percentile, air way wall thickening by the square root of wall area for a theoretical airway with 10mm lumen perimeter (Pi10) and gas trapping by the mean lung density expiratory/inspiratory (E/I)-ratio. Participants were classified by entry FEV1/FVC: group 1>70%; group 2<70% but >LLN; and group 3<LLN. 32 restricted subjects, i.e. FEV1/FVC >70% but FEV1 <80% predicted, were excluded. Multivariate regression analysis correcting for covariates was used to asses the extent of emphysema, airway wall thickening and gas trapping according to three groups of airflow limitation.

Results

Mean (standard deviation) age was 62.5 (5.2) years and packyears smoked was 41.0 (18.0). Group 2 subjects when compared to group 1 had a significantly lower 15th percentile, −920.6 HU versus −912.2 HU; a higher Pi10, 2.87 mm versus 2.57 mm; and a higher E/I-ratio, 88.6% versus 85.6% (all p<0.001).

Conclusion

Subjects with an FEV1/FVC<70%, but above the LLN, have a significant greater degree of structural lung changes on CT compared to subjects without airflow limitation.  相似文献   

12.

Background

Lung function at the end of life depends on its peak and subsequent decline. Because obesity is epidemic in young adulthood, we quantified age-related changes in lung function relative to body mass index (BMI).

Methods

The Coronary Artery Risk Development in Young Adults (CARDIA) study in 1985–86 (year 0) recruited 5,115 black and white men and women, aged 18–30. Spirometry testing was conducted at years 0, 2, 5 and 10. We estimated 10 year change in FVC, FEV1 and FEV1/FVC according to baseline BMI and change in BMI within birth cohorts with initial average ages 20, 24, and 28 years, controlling for race, sex, smoking, asthma, physical activity, and alcohol consumption.

Measurements and Main Results

Participants with baseline BMI < 21.3 kg/m2 experienced 10 year increases of 71 ml in FVC and 60 ml in FEV1 and neither measure declined through age 38. In contrast, participants with baseline BMI ≥ 26.4 kg/m2 experienced 10 year decreases of 185 ml in FVC and 64 ml in FEV1. FEV1/FVC increased with increasing BMI. Weight gain was also associated with lung function. Those who gained the most weight over 10 years had the largest decrease in FVC, but FVC increased with weight gain in those initially thinnest. In contrast, FEV1 decreased with increasing weight gain in all participants, with maximum decline in obese individuals who gained the most weight during the study.

Conclusion

Among healthy young adults, increasing BMI in the initially thin participants was associated with increasing then stable lung function through age 38, but there were substantial lung function losses with higher and increasing fatness. These results suggest that the obesity epidemic threatens the lung health of the general population.  相似文献   

13.

Background

Numerous studies have demonstrated associations between genetic markers and COPD, but results have been inconsistent. One reason may be heterogeneity in disease definition. Unsupervised learning approaches may assist in understanding disease heterogeneity.

Methods

We selected 31 phenotypic variables and 12 SNPs from five candidate genes in 308 subjects in the National Emphysema Treatment Trial (NETT) Genetics Ancillary Study cohort. We used factor analysis to select a subset of phenotypic variables, and then used cluster analysis to identify subtypes of severe emphysema. We examined the phenotypic and genotypic characteristics of each cluster.

Results

We identified six factors accounting for 75% of the shared variability among our initial phenotypic variables. We selected four phenotypic variables from these factors for cluster analysis: 1) post-bronchodilator FEV1 percent predicted, 2) percent bronchodilator responsiveness, and quantitative CT measurements of 3) apical emphysema and 4) airway wall thickness. K-means cluster analysis revealed four clusters, though separation between clusters was modest: 1) emphysema predominant, 2) bronchodilator responsive, with higher FEV1; 3) discordant, with a lower FEV1 despite less severe emphysema and lower airway wall thickness, and 4) airway predominant. Of the genotypes examined, membership in cluster 1 (emphysema-predominant) was associated with TGFB1 SNP rs1800470.

Conclusions

Cluster analysis may identify meaningful disease subtypes and/or groups of related phenotypic variables even in a highly selected group of severe emphysema subjects, and may be useful for genetic association studies.  相似文献   

14.

Background

Interactions between spirometry and patient-reported outcomes in COPD are not well understood. This systematic review and study-level analysis investigated the relationship between changes in FEV1 and changes in health status with bronchodilator therapy.

Methods

Six databases (to October 2009) were searched to identify studies with long-acting bronchodilator therapy reporting FEV1 and health status, dyspnoea or exacerbations. Mean and standard deviations of treatment effects were extracted for each arm of each study. Relationships between changes in trough FEV1 and outcomes were assessed using correlations and random-effects regression modelling. The primary outcome was St George''s Respiratory Questionnaire (SGRQ) total score.

Results

Thirty-six studies (≥3 months) were included. Twenty-two studies (23,654 patients) with 49 treatment arms each contributing one data point provided SGRQ data. Change in trough FEV1 and change in SGRQ total score were negatively correlated (r = -0.46, p < 0.001); greater increases in FEV1 were associated with greater reductions (improvements) in SGRQ. The correlation strengthened with increasing study duration from 3 to 12 months. Regression modelling indicated that 100 mL increase in FEV1 (change at which patients are more likely to report improvement) was associated with a statistically significant reduction in SGRQ of 2.5 (95% CI 1.9, 3.1), while a clinically relevant SGRQ change (4.0) was associated with 160.6 (95% CI 129.0, 211.6) mL increase in FEV1. The association between change in FEV1 and other patient-reported outcomes was generally weak.

Conclusions

Our analyses indicate, at a study level, that improvement in mean trough FEV1 is associated with proportional improvements in health status.  相似文献   

15.

Background

Reduced forced expiratory volume in 1 second (FEV1) and the ratio of FEV1 to forced vital capacity (FVC) are strong predictors of mortality and lung function is higher among individuals with exceptional longevity. However, genetic factors associated with lung function in individuals with exceptional longevity have not been identified.

Method

We conducted a genome wide association study (GWAS) to identify novel genetic variants associated with lung function in the Long Life Family Study (LLFS) (n = 3,899). Replication was performed using data from the CHARGE/SpiroMeta consortia. The association between SNPs and FEV1 and FEV1/FVC was analyzed using a linear mixed effects model adjusted for age, age2, sex, height, field center, ancestry principal components and kinship structure to adjust for family relationships separately for ever smokers and never smokers. In the linkage analysis, we used the residuals of the FEV1 and FEV1/FVC, adjusted for age, sex, height, ancestry principal components (PCs), smoking status, pack-years, and field center.

Results

We identified nine SNPs in strong linkage disequilibrium in the CYP2U1 gene to be associated with FEV1 and a novel SNP (rs889574) associated with FEV1/FVC, none of which were replicated in the CHARGE/SpiroMeta consortia. Using linkage analysis, we identified a novel linkage peak in chromosome 2 at 219 cM for FEV1/FVC (LOD: 3.29) and confirmed a previously reported linkage peak in chromosome 6 at 28 cM (LOD: 3.33) for FEV1.

Conclusion

Future studies need to identify the rare genetic variants underlying the linkage peak in chromosome 6 for FEV1.

Electronic supplementary material

The online version of this article (doi:10.1186/s12931-014-0134-x) contains supplementary material, which is available to authorized users.  相似文献   

16.

Introduction

Air pollutant exposure has been associated with an increase in inflammatory markers and a decline in lung function in asthmatic children. Several studies suggest that dietary intake of fruits and vegetables might modify the adverse effect of air pollutants.

Methods

A total of 158 asthmatic children recruited at the Children''s Hospital of Mexico and 50 non-asthmatic children were followed for 22 weeks. Pulmonary function was measured and nasal lavage collected and analyzed every 2 weeks. Dietary intake was evaluated using a 108-item food frequency questionnaire and a fruit and vegetable index (FVI) and a Mediterranean diet index (MDI) were constructed. The impact of these indices on lung function and interleukin-8 (IL-8) and their interaction with air pollutants were determined using mixed regression models with random intercept and random slope.

Results

FVI was inversely related to IL-8 levels in nasal lavage (p < 0.02) with a significant inverse trend (test for trend p < 0.001), MDI was positively related to lung function (p < 0.05), and children in the highest category of MDI had a higher FEV1 (test for trend p < 0.12) and FVC (test for trend p < 0.06) than children in the lowest category. A significant interaction was observed between FVI and ozone for FEV1 and FVC as was with MDI and ozone for FVC. No effect of diet was observed among healthy children.

Conclusion

Our results suggest that fruit and vegetable intake and close adherence to the Mediterranean diet have a beneficial effect on inflammatory response and lung function in asthmatic children living in Mexico City.  相似文献   

17.

Background

The distribution of airway responsiveness in a general population of non-smokers without respiratory symptoms has not been established, limiting its use in clinical and epidemiological practice. We derived reference equations depending on individual characteristics (i.e., sex, age, baseline lung function) for relevant percentiles of the methacholine two-point dose-response slope.

Methods

In a reference sample of 1567 adults of the SAPALDIA cross-sectional survey (1991), defined by excluding subjects with respiratory conditions, responsiveness during methacholine challenge was quantified by calculating the two-point dose-response slope (O''Connor). Weighted L1-regression was used to estimate reference equations for the 95th , 90th , 75th and 50th percentiles of the two-point slope.

Results

Reference equations for the 95th , 90th , 75th and 50th percentiles of the two-point slope were estimated using a model of the form a + b* Age + c* FEV1 + d* (FEV1)2 , where FEV1 corresponds to the pre-test (or baseline) level of FEV1. For the central half of the FEV1 distribution, we used a quadratic model to describe the dependence of methacholine slope on baseline FEV1. For the first and last quartiles of FEV1, a linear relation with FEV1 was assumed (i.e., d was set to 0). Sex was not a predictor term in this model. A negative linear association with slope was found for age. We provide an Excel file allowing calculation of the percentile of methacholine slope of a subject after introducing age – pre-test FEV1 – and results of methacholine challenge of the subject.

Conclusion

The present study provides equations for four relevant percentiles of methacholine two-point slope depending on age and baseline FEV1 as basic predictors in an adult reference population of non-obstructive and non-atopic persons. These equations may help clinicians and epidemiologists to better characterize individual or population airway responsiveness.  相似文献   

18.

Background

The assessment of bronchodilator-induced change in forced vital capacity (FVC) is dependent on forced expiratory time (FET) in subjects with airflow limitation. Limited information is available on the concurrent responses of FVC, forced expiratory volume in six seconds (FEV6), and FET in the bronchodilation test among patients with obstructive airways disease or in the general population. The aim of this study was to assess the changes in FEV6, FVC, and FET, and their relationships in a standardized bronchodilation test in the general population.

Methods

We studied bronchodilation response in a general adult population sample of 628 individuals (260 men, 368 women) with flow-volume spirometry. The largest FVC, the corresponding FET and the largest FEV6 both at the baseline and after 0.4 mg of inhaled salbutamol were selected for analysis.

Results

After administration of salbutamol FEV6 decreased on average -13.4 (95% CI -22.3 to -4.5) ml or -0.2% (-0.4% to 0.0%) from the baseline. The 95th percentile of change in FEV6 was 169.1 ml and 5.0%. FVC decreased on average -42.8 (-52.4 to -33.3) ml or -1.0% (-1.2% to -0.7%). Concurrently FET changed on average -0.2 (-0.4 to 0.0) seconds or 0.4% (-1.4% to 2.3%). There were four subjects with an increase of FVC over 12% and only one of these was associated with prolonged FET after salbutamol. Changes in FEV6 and FVC were more frequently positive in subjects with reduced FEV1/FVC in baseline spirometry.

Conclusion

In general adult population, both FEV6 and FVC tended to decrease, but FET remained almost unchanged, in the bronchodilation test. However, those subjects with signs of airflow limitation at the baseline showed frequently some increase of FEV6 and FVC in the bronchodilation test without change in FET. We suggest that FEV6 could be used in assessment of bronchodilation response in lieu of FVC removing the need for regulation of FET during bronchodilation testing.  相似文献   

19.

Background

Lymphangioleiomyomatosis (LAM) is a rare lung disease characterised by progressive airflow obstruction. No effective medical treatment is available but therapy with sirolimus has shown some promise. The aim of this observational study was to evaluate sirolimus in progressive LAM.

Methods

Sirolimus (trough level 5 - 10 ng/ml) was administered to ten female patients (42.4 ± 11.9 years) with documented progression. Serial pulmonary function tests and six-minute-walk-distance (6-MWD) assessments were performed.

Results

The mean loss of FEV1 was -2.30 ± 0.52 ml/day before therapy and a significant mean gain of FEV1 of 1.19 ± 0.26 ml/day was detected during treatment (p = 0.001). Mean FEV1 and FVC at baseline were 1.12 ± 0.15 l (36.1 ± 4.5%pred.) and 2.47 ± 0.25 l (69.2 ± 6.5%pred.), respectively. At three and six months during follow-up a significant increase of FEV1 and FVC was demonstrated (3 months ΔFEV1: 220 ± 82 ml, p = 0.024; 6 months ΔFEV1: 345 ± 58 ml, p = 0.001); (3 months ΔFVC: 360 ± 141 ml, p = 0.031; 6 months ΔFVC: 488 ± 138 ml, p = 0.006). Sirolimus was discontinued in 3 patients because of serious recurrent lower respiratory tract infection or sirolimus-induced pneumonitis. No deaths and no pneumothoraces occurred during therapy.

Conclusions

Our data suggest that sirolimus might be considered as a therapeutic option in rapidly declining LAM patients. However, sirolimus administration may be associated with severe respiratory adverse events requiring treatment cessation in some patients. Moreover, discontinuation of sirolimus is mandatory prior to lung transplantation.  相似文献   

20.

Background

Oxidative stress related genes modify the effects of ambient air pollution or tobacco smoking on lung function decline. The impact of interactions might be substantial, but previous studies mostly focused on main effects of single genes.

Objectives

We studied the interaction of both exposures with a broad set of oxidative-stress related candidate genes and pathways on lung function decline and contrasted interactions between exposures.

Methods

For 12679 single nucleotide polymorphisms (SNPs), change in forced expiratory volume in one second (FEV1), FEV1 over forced vital capacity (FEV1/FVC), and mean forced expiratory flow between 25 and 75% of the FVC (FEF25-75) was regressed on interval exposure to particulate matter <10 µm in diameter (PM10) or packyears smoked (a), additive SNP effects (b), and interaction terms between (a) and (b) in 669 adults with GWAS data. Interaction p-values for 152 genes and 14 pathways were calculated by the adaptive rank truncation product (ARTP) method, and compared between exposures. Interaction effect sizes were contrasted for the strongest SNPs of nominally significant genes (pinteraction<0.05). Replication was attempted for SNPs with MAF>10% in 3320 SAPALDIA participants without GWAS.

Results

On the SNP-level, rs2035268 in gene SNCA accelerated FEV1/FVC decline by 3.8% (pinteraction = 2.5×10−6), and rs12190800 in PARK2 attenuated FEV1 decline by 95.1 ml pinteraction = 9.7×10−8) over 11 years, while interacting with PM10. Genes and pathways nominally interacting with PM10 and packyears exposure differed substantially. Gene CRISP2 presented a significant interaction with PM10 (pinteraction = 3.0×10−4) on FEV1/FVC decline. Pathway interactions were weak. Replications for the strongest SNPs in PARK2 and CRISP2 were not successful.

Conclusions

Consistent with a stratified response to increasing oxidative stress, different genes and pathways potentially mediate PM10 and tobacco smoke effects on lung function decline. Ignoring environmental exposures would miss these patterns, but achieving sufficient sample size and comparability across study samples is challenging.  相似文献   