首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Background

Healthy atrial fibrillation (AF) patients will eventually outgrow their low thromboembolic risk. The purpose of this study is to compare the development of cardiovascular disease in healthy AF patients as compared to healthy sinus rhythm patients and to assess appropriate anticoagulation treatment.

Methods

Forty-one idiopathic paroxysmal AF patients (56 ± 10 years, 66% male) were compared with 45 healthy sinus rhythm patients. Patients were free of hypertension, antihypertensive and antiarrhythmic drugs, diabetes, congestive heart failure, coronary artery or peripheral vascular disease, previous stroke, thyroid, pulmonary and renal disease, and structural abnormalities on echocardiography.

Results

Baseline characteristics and echocardiographic parameters were the same in both groups. During 10.7 ± 1.6 years, cardiovascular disease and all-cause death developed significantly more often in AF patients as compared to controls (63% vs 31%, log rank p < 0.001). Even after the initial 5 years of follow-up, survival curves show divergent patterns (log rank p = 0.006). Mean duration to reach a CHA2DS2-VASc score > 1 among AF patients was 5.1 ± 3.0 years. Five of 24 (21%) patients with CHA2DS2-VASc > 1 did not receive oral anticoagulation therapy at follow-up. Mean duration of over- or undertreatment with oral anticoagulation in patients with CHA2DS2-VASc > 1 was 5 ± 3.0 years.

Conclusion

The majority of recently diagnosed healthy AF patients develop cardiovascular diseases with a consequent change in thromboembolic risk profile within a short time frame. A comprehensive follow-up of this patient category is necessary to avoid over- and undertreatment with anticoagulants.

  相似文献   

2.
BackgroundHigh-power short-duration (HPSD) and cryoballoon ablation (CBA) has been used for pulmonary vein isolation (PVI).ObjectiveWe aimed to compare the efficacy of PVI between CBA and HPSD ablation in patients with paroxysmal atrial fibrillation (PAF).MethodsWe retrospectively analyzed 251 consecutive PAF patients from January 2018 to July 2020. Of them, 124 patients (mean age 57.2 ± 10.1 year) received HPSD and 127 patients (mean age 59.6 ± 9.4 year) received CBA. In HPSD group, the radiofrequency energy was set as 50 W/10 s at anterior wall and 40 W/10 s at posterior wall. In CBA group, 28 mm s generation cryoballoon was used for PVI according the guidelines.ResultsThere was no significant difference in baseline characteristics between these 2 groups. The time to achieve PVI was significantly shorter in cryoballoon ablation group than in HPSD group (20.6 ± 1.7 min vs 51.8 ± 36.3, P = 0.001). The 6-month overall recurrence for atrial tachyarrhythmias was not significantly different between the two groups (HPSD:14.50% vs CBA:11.0%, P = 0.40). There were different types of recurrent atrial tachyarrhythmia between these 2 groups. Recurrence as atrial flutter was significantly more common in CBA group compared to HPSD group (57.1% vs 12.5%, P = 0.04).ConclusionIn PAF patients, CBA and HPSD had a favourable and comparable outcome. The recurrence pattern was different between CBA and HPSD groups.  相似文献   

3.
Background

Patients with chronic total coronary occlusions (CTO) are at increased risk for poor clinical outcomes. We aimed to determine the incidence of CTO percutaneous coronary intervention (PCI) and to identify CTO patients at risk for cardiac events in the nationwide Netherlands Heart Registration (NHR).

Methods

We included all PCI procedures with ≥1 CTO registered in the NHR from January 2015 to December 2018, excluding acute interventions. We used multivariable logistic regression of baseline characteristics to calculate the risk for events as odds ratios (OR) with 95% confidence intervals (CI).

Results

Of the PCIs performed during the study period, 6.3% (8,343/133,042) were for CTOs, with the percentage increasing significantly over time from 5.9% in 2015 to 6.6% in 2018 (p < 0.001). Coronary artery bypass grafting <24 h was carried out in 0.3%, and the only significant predictor was diabetes mellitus (OR 2.97, 95% CI 1.04–8.49, p = 0.042). Myocardial infarction (MI) <30 days occurred in 0.5%, and renal insufficiency (i.e. estimated glomerular filtration rate <30 ml/min per 1.73 m2) was identified as an independent predictor (OR 4.70, 95% CI 1.07–20.61, p = 0.040). Among patients undergoing CTO-PCI, 1‑year mortality was 3.7%, and independent predictors included renal insufficiency (OR 5.59, 95% CI 3.25–9.59, p < 0.001), left ventricular ejection fraction <30% (OR 3.43, 95% CI 2.00–5.90, p < 0.001), previous MI (OR 1.62, 95% CI 1.14–2.31, p = 0.007) and age (OR 1.06 per year increment, 95% CI 1.04–1.07, p < 0.001). Target-vessel revascularisation <1 year occurred in 11.3%.

Conclusion

CTO-PCI is still infrequently performed in the Netherlands. The most important predictor of mortality after CTO-PCI was renal insufficiency. Identification of patients at risk may help improve the prognosis of CTO patients in the future.

  相似文献   

4.
Background

Pulmonary artery (PA) dilatation is often seen in pulmonary hypertension (PH) and is considered a long-term consequence of elevated pressure. The PA dilates over time and therefore may reflect disease severity and duration. Survival is related to the stage of the disease at the time of diagnosis and therefore PA diameter might be used to predict prognosis. This study evaluates the outcome of patients with pulmonary arterial hypertension (PAH) and chronic thrombo-embolic pulmonary hypertension (CTEPH) and investigates whether PA diameter at the time of diagnosis is associated with mortality.

Methods

Patients visiting an outpatient clinic of a tertiary centre between 2004 and 2018 with a cardiac catheterisation confirmed diagnosis of PAH or CTEPH and a CT scan available for PA diameter measurement were included. PA diameter and established predictors of survival were collected (New York Heart Association (NYHA) class, N‑terminal pro-brain natriuretic peptide (NT-proBNP) level and 6‑min walking distance (6MWD)).

Results

In total 217 patients were included (69% female, 71% NYHA class ≥III). During a median follow-up of 50 (22–92) months, 54% of the patients died. Overall survival was 87% at 1 year, 70% at 3 years and 58% at 5 years. The mean PA diameter was 34.2 ± 6.2 mm and was not significantly different among all the diagnosis groups. We found a weak correlation between PA diameter and mean PA pressure ( r = 0.23, p < 0.001). Male sex, higher age, shorter 6MWD and higher NT-proBNP level were independently associated with mortality, but PA diameter was not.

Conclusion

The prognosis of PAH and CTEPH is still poor. Known predictors of survival were confirmed, but PA diameter at diagnosis was not associated with survival in PAH or CTEPH patients.

  相似文献   

5.
IntroductionThe endoscopic laser balloon ablation system (EAS) is a relatively novel technique to perform pulmonary vein isolation (PVI) in the treatment of atrial fibrillation (AF). The present study aimed to report the results of the first 50 patients treated in the Netherlands with the EAS in terms of procedural characteristics and AF-free survival.MethodsFifty patients successfully underwent EAS PVI. Median follow-up was 17 months. Mean age was 56 years, 82 % had paroxysmal AF.Results99 % of the pulmonary veins were successfully isolated with the EAS. Mean procedure time was 171 min and mean fluoroscopy time was 36 min. One procedure was complicated by a temporary phrenic nerve palsy (2 %). During follow-up, 58 % of patients remained free of AF without the use of antiarrhythmic drugs.ConclusionPVI with EAS is associated with a low risk of complications and a medium-term AF-free survival comparable with other PVI techniques.

Electronic supplementary material

The online version of this article (doi:10.1007/s12471-014-0624-y) contains supplementary material, which is available to authorized users.  相似文献   

6.
Introduction

An increased body mass index (BMI) (>25 kg/m2) is associated with a wide range of electrocardiographic changes. However, the association between electrocardiographic changes and BMI in healthy young individuals with a normal BMI (18.5–25 kg/m2) is unknown. The aim of this study was to evaluate the association between BMI and electrocardiographic parameters.

Methods

Data from 1,290 volunteers aged 18 to 30 years collected at our centre were analysed. Only subjects considered healthy by a physician after review of collected data with a normal BMI and in sinus rhythm were included in the analysis. Subjects with a normal BMI (18.5–25 kg/m2) were divided into BMI quartiles analysis and a backward multivariate regression analysis with a normal BMI as a continuous variable was performed.

Results

Mean age was 22.7 ± 3.0 years, mean BMI was 22.0, and 73.4% were male. There were significant differences between the BMI quartiles in terms of maximum P-wave duration, P-wave balance, total P-wave area in lead V1, PR-interval duration, and heart axis. In the multivariate model maximum P-wave duration (standardised coefficient (SC) = +0.112, P < 0.001), P-wave balance in lead V1 (SC = +0.072, P < 0.001), heart axis (SC = −0.164, P < 0.001), and Sokolow-Lyon voltage (SC = −0.097, P < 0.001) were independently associated with BMI.

Conclusion

Increased BMI was related with discrete electrocardiographic alterations including an increased P-wave duration, increased P-wave balance, a leftward shift of the heart axis, and decreased Sokolow-Lyon voltage on a standard twelve lead electrocardiogram in healthy young individuals with a normal BMI.

  相似文献   

7.
BackgroundClinical management of vaso-vagal syncope (VVS) remains challenging since no therapy has proven to completely prevent VVS recurrence.ObjectiveThe purpose of this study was to analyze the mid-term outcome of cryoballoon (CB) cardioneuroablation achieved by pulmonary vein isolation (PVI) in patients with VVS.MethodsPatients who underwent CB cardioneuroablation in our centers between January 2014 to June 2018 were included. All patients had a history of VVS or pre-syncope despite therapeutic attempts with medical and/or pacing treatments. Patients were excluded in case of structural heart diseases, cerebrovascular diseases or suspected drug-related syncope. Both heart rate (HR) and atrio-ventricular (AV) interval were analyzed on the 12-lead electrocardiogram (ECG) the day before the procedure, the day after, and in the follow-up.ResultsIn total, 26 patients (76.9% males, 37.5 ± 9.0 years old) were included. All patients underwent a successful procedure with the 28 mm second-generation Arctic Front Advance CB. No major complication occurred. At a mean follow-up of 20.1 ± 11.6 months the freedom from VVS or reflex pre-syncope was 83,7%, with 22 patients free from any clinical recurrence. Basal HR significantly increased the day after the procedure (57.2 bpm vs 78.3 bpm, p < 0.001), while at the final follow-up it stabilized at a value halfway between the 2 previous ones (69.8 bpm, p = 0.0086). The AV interval didn’t modify significantly after the procedure.ConclusionEndocardial autonomic denervation achieved by CB PVI appears to be an effective and safe treatment option for patients with refractory VVS and reflex pre-syncope.  相似文献   

8.

Background

Adenosine infusion after pulmonary vein isolation (PVI) with radiofrequency energy reveals dormant muscular sleeves and predicts atrial fibrillation (AF) recurrence. The aim of our study was to determine whether adenosine could reveal dormant PV sleeves after cryoballoon isolation and study its effect on long-term recurrence of AF.

Methods

Patients with paroxysmal AF underwent cryoballoon PVI. After PVI, adenosine 25 mg was infused to test for dormant muscular sleeves in each vein. If reconnection under adenosine was shown, further cryoballoon ablation was performed until no more reconnection occurred. Follow-up was performed with ECG, 24-h Holter recording, and a symptom questionnaire at three monthly intervals. Transtelephonic Holter monitoring was performed for 1 month before and 3 months after PVI. Patients who underwent cryoballoon PVI without adenosine administration were used as controls for comparison.

Results

In the study group (n = 34, 24 males), adenosine revealed dormant sleeves in 9/132 (8 %) veins, and 7/34 (21 %) patients. All but one vein was further treated until the dormant sleeves were isolated. During a mean follow-up of 520 ± 147 days, 23/34 (68 %) patients were free of AF without antiarrhythmic drugs (AADs). In the control group (n = 65, 46 males), 29/65 (46 %) were free of AF without AADs. There were significantly less AF recurrences in the study group (p = 0.04).

Conclusions

Adenosine administration after cryoballoon PVI reveals dormant muscular sleeves in 21 % of patients. Clinical follow-up shows that adenosine testing is effective in reducing AF recurrence after cryoballoon ablation.  相似文献   

9.
BackgroundThe single procedure success rates of durable pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) varies between 80 and 90%. Ablation index, incorporating contact force, stability, time and power is a more profound parameter of significant lesion size and has been established. Equally important is a stringent contiguity of the lesion set.Methods and resultsA total number of 100 consecutive patients undergoing de-novo catheter ablation for paroxysmal atrial fibrillation (PAF) were analyzed between 2016 and 2019. In the first 50 patients (group A) PVI was performed using a surround flow, contact force catheter (Biosense Webster Thermocool STSF, Biosense Webster, USA) with a drag-and-ablate technique to encircle the PVs. In the following 50 patients (group B), PVI was performed using ablation index and a stringent lesion contiguity with an interlesion distance (ILD) of <5 mm. The baseline characteristics showed no significant differences between both groups. During a mean follow-up of 18 ± 3 months after a single procedure, 36 (72%) patients of group A were free of arrhythmia recurrence versus 43 (86%) patients in group B (p = 0.047). A total of 14 patients (group A: 10 (20%), group B: 4 (8%); underwent a redo-procedure. 7 patients of group A (14%) and 2 patients of group B (4%) showed recovered veins. In 3 patients of group A and 2 patients of group B the PVs were durably isolated. In these patients persistent AF recurrence was caused by extra-PV AF sources. Four patients of group A and three patients of group B had continued paroxysmal or persistent AF but did not undergo redo-procedure. With regard to the procedural data, the procedure time, the total energy and the fluoroscopy time were significantly lower in group B (AI and ILD <5 mm) (128.86 ± 18.19 versus 115.35 ± 15.38; p < 0.05; 1619.16 ± 988.56 versus 1186.26 ± 756.34; p < 0.05; 11.49 ± 3.20 versus 9.66 ± 3.86; p = 0.04). Both procedures were performed with a low number of complications, no pericardial effusion was seen in either group.ConclusionsPVI using ablation index in combination with a stringent lesion contiguity improves clinical outcome after first-time PVI with lower PVI recovery, shorter procedure times, lower total energy and shorter fluoroscopy times and therefore, is more efficient.  相似文献   

10.
Aims

Spontaneous coronary artery dissection (SCAD) is increasingly recognised as a cause of myocardial infarction, but psychological characteristics of patients with SCAD have not yet been extensively investigated. We assessed the prevalence of a broad range of psychological and clinical factors, and their inter-relationships in patients with a history of SCAD. Furthermore, we investigated whether specific clusters of patients with SCAD can be identified.

Methods

Participants were recruited between March and May 2019 from a Dutch SCAD database and completed online questionnaires. Clinical information was verified by review of medical records. Participants were predominantly female (172/183; 94%). Analyses focused on the 172 female patients (mean age 52.0 ± 7.5 years, 37% postmenopausal).

Results

The most common comorbidities of SCAD were migraine (52%), fibromuscular dysplasia (FMD; 29%), chronic pain (29%), and tinnitus (28%). Six women (3%) had pregnancy-associated SCAD. Traditional cardiovascular risk factors were rare (<10%), except for hypertension (31%). Psychological assessment indicated high levels of perceived stress (PSS-10 ≥14; 50%), fatigue (FAS-10 ≥22; 56%), and a frequent history of burnout (25%). The prevalence of depression (9%) and anxiety (12%) was relatively low. Three clusters were identified: (A) FMD and chronic non-ischaemic conditions (tinnitus, chronic pain, and irritable bowel syndrome); (B) migraine; and (C) none of these conditions.

Conclusion

This study shows that perceived stress and fatigue are common in patients with SCAD, in addition to prevalent comorbid FMD, migraine, tinnitus, and non-ischaemic pain conditions. These factors may add to developing tailored rehabilitation programmes for patients with SCAD.

  相似文献   

11.
BackgroundEffective therapies are needed to prevent the secondary injury and poor prognosis associated with emergency craniotomy of traumatic brain injury (TBI).Hypothesis/PurposeThe wound-healing medicine Yunnan Baiyao (YB) and Xingnaojing (XNJ) adjunct-therapy may improve the outcome of orthodox mono-therapy (OT).Study designRandomized controlled trial.MethodsEighty patients with moderate-to-severe TBI received emergency craniotomy (within 12 h after TBI) at the Chinese PLA General Hospital before being randomly assigned to 4 different treatments (n = 20) for 7 days: 1) OT; 2) OT+XNJ (i.v. 20 ml/daily); 3) OT+low dose-YB (oral, 1,000 mg/day); 4) OT+high dose-YB, 2,000 mg/day).ResultsGCS score was improved more quickly and became significantly higher in XNJ, l-YB, h-YB groups than in OT group (p<0.01). Serum S100B peaked higher but declined more slowly in OT group than in other groups (p<0.01). On postoperative Day 7, S100B was 20% below baseline in YB and XNJ groups but remained 19% above baseline in OT group which also lost 38% of superoxide dismutase (SOD) activity on Day 3 and recovered 69% of SOD on Day 7 whereas the YB and XNJ groups lost 16%∼23% of SOD activity on Day 3 and recovered 92%∼99% of SOD on Day 7 (p<0.01). Clinical prognosis (Glasgow Outcome Scale and Karnofsky Performance Scale) were significantly better (25%∼30%) in the XNJ, l-YB and h-YB groups than in OT group 3 months post-surgery and were correlated with serum S100B and SOD.ConclusionsYB and XNJ adjunct therapies improved postoperative recovery and clinical prognosis in patients with moderate-to-severe TBI partly through divergent regulation of S100B and SOD pathways. (The trial was registered at Chinese Clinical Trial Registry (ChiCTR) trial registration number: ChiCTR2000030280)  相似文献   

12.
Introduction

In the care of heart failure patients, telemonitoring is receiving growing attention. The main purpose of this study was to determine the effect of continuous telemonitoring with an implantable loop recorder (ILR, Reveal XT), a novel strategy in the management of stable heart failure patients without a cardiac implantable device. Furthermore, little is known about the incidence of subclinical arrhythmias in this specific group of patients.

Materials and Methods

Stable heart failure patients, New York Heart Association Class II and III, without recent hospitalisation or upcoming intervention, were included. After implantation of the ILR there was regular contact with the research nurse on a pre-specified basis. Clinic visits and telephonic interviews were alternated for a minimum of 1 year. Parallel visits to their treating physician continued according to standard care. The treating physician was blinded for the ILR findings, accept for pre-specified, significant arrhythmic events.

Results

Thirty patients were included and followed for a median duration of 12 months. In 13 patients, data from the loop recorder led to therapeutic changes. One patient received a pacemaker. Eight patients developed atrial fibrillation, all subclinical, with a mean burden of 65.8 ± 173.2 min/day.

Conclusion

The use of an ILR could potentially impact patient management. Additional study is needed in different patient populations (e. g. higher risk groups) to assess if an ILR could also impact on endpoints such as heart failure hospitalisation.

  相似文献   

13.

Background

Paroxysmal atrial fibrillation (PAF) is defined as recurrent AF terminating spontaneously within 7 days. This definition allows the consideration of any AF occurrence lasting < 7 days as paroxysmal, irrespective of the frequency and duration of episodes. The aim of this study was to investigate symptomatic AF burden (AFB) defined as total duration of symptomatic AF episodes within 3 months prior to abalation, for prediction of outcome after pulmonary vein isolation (PVI).

Methods

A total of 320 consecutive patients with symptomatic AF (PAF=244, men=214, age=58 y) were enrolled. AFB in patients with PAF was defined as time spent in AF within 3 months prior to PVI. After the AFB cut-off point was optimized at 500 h, patients with PAF were categorized into 2 groups: Group 1 - patients with AFB< 500 h (n=192), Group 2 - patients with AFB≥ 500 h (n=52). Patients with persistent AF (PersAF, n = 76) comprised control group (Group 3). PVI was performed either with irrigated tip catheter (n=215) or using cryoballoon (n=105). The endpoint of study was first documented recurrence of AF >30 sec.

Results

Symptomatic AFB was found to be appropriate for prediction of outcome after PVI. The freedom from AF within 2 years was observed in 69%, 31%, and 43% patients in Group 1, 2 and 3, respectively (Group 1 vs. Group 2, p < .001; Group 1 vs. Group 3, p< .001; Group 2 vs. Group 3, p = 0.46).

Conclusions

Low AFB < 500 h /3 months was associated with better outcome after PVI. Patients with PAF and high AFB should be treated as patients with PersAF.  相似文献   

14.
BackgroundPulmonary vein isolation (PVI) modulates the intrinsic cardiac autonomic nervous system (ANS). We evaluated the impact of PVI on 5 non-invasive autonomic tests.MethodsThirty patients (76% male, mean age 60.37 ± 9.02 years) with paroxysmal atrial fibrillation (AF) underwent cryoballoon-guided PVI. Five autonomic tests were performed 24hrs before and after PVI (N = 30) and repeated after 6months (N = 22). Parasympathetic function was measured by heart rate (HR) variability during deep breathing (E/I ratio, I-E difference), Valsalva maneuver (Valsalva-ratio) and head-up tilt test (30/15 ratio). Sympathetic function was measured by systolic BP response to sustained handgrip and 10’ tilting and by diastolic BP response to cold water.Results24hrs after PVI, baseline HR increased from 57.93 ± 9.06 bpm to 71.10 ± 12.75 bpm (p < 0.001). At 6 months, baseline HR was lower than immediately post-PVI (62.59 ± 7.89 vs 71.36 ± 13.58 bpm, p = 0.032) but still higher in comparison to pre-PVI (62.59 ± 7.89 vs 57.09 ± 8.80 bpm, p < 0.001). No differences were seen in baseline BP and parasympathetic tests acutely and at 6months. Besides an acute lowering in systolic BP increase during handgrip test, all sympathetic tests remained unchanged.ConclusionsAn acute HR increase attenuated at 6months and an acute lowered systolic BP response to sustained handgrip were the only changes after cryoballoon-guided PVI. Non-invasive autonomic tests seem therefore not appropriate to evaluate the autonomic modulatory effect of PVI, either due to a too limited sensitivity or a too localized effect of PVI to influence test results.  相似文献   

15.
BackgroundCryoballoon pulmonary vein isolation (PVI) is a common therapy for atrial fibrillation (AF). While moderately increased sinus rhythm heart rate (HR) after PVI has been observed, inappropriate sinus tachycardia (IST) is a rare phenomenon. We aimed to investigate the prevalence and natural history of an abnormal sinus HR response after cryoballoon PVI.MethodsWe included 169/646 (26.2%) patients with AF undergoing PVI with available Holter recordings before and 3, 6 and 12 months after the procedure. Patients with AF on Holter monitoring were excluded. Mean HR increase ≥ 20 bpm or an IST-like pattern (mean HR > 90 bpm or > 80 bpm when beta-blocking agents were used) following PVI was categorised as abnormal sinus HR response.ResultsFollowing PVI, mean HR ± standard deviation increased in the entire group from 63.5 ± 8.4 to 69.1 ± 9.9 bpm at 3 months (p < 0.001), and to 71.9 ± 9.4 bpm at 6 months (p < 0.001). At 12 months, mean HR was 71.2 ± 10.1 bpm (p < 0.001). Only 7/169 patients (4.1%) met criteria for abnormal sinus HR response: mean HR was 61.9 ± 10.6 bpm (pre-ablation), 84.6 ± 9.8 bpm (3 months), 80.1 ± 6.5 bpm (6 months) and 76.3 ± 10.1 bpm (12 months). Even at 12 months, mean HR was significantly different from that pre-ablation in this group (p = 0.033). However, in patients meeting IST-like pattern criteria, mean HR at 12 months was no longer significantly different from that pre-ablation.ConclusionFew patients had an abnormal sinus HR response after PVI. Peak HR was observed 3 months after PVI, but HR was still significantly increased 12 months post-ablation compared with pre-ablation. An IST-like pattern was rarely observed. In these patients, HR decreased to pre-ablation values within a year.  相似文献   

16.
IntroductionConflicting results regarding the impact of left common pulmonary vein (LCPV) on clinical outcome of atrial fibrillation (AF) ablation with cryoballoon technology have been reported.MethodsWe systematically searched PubMed and Cochrane library for articles that compared the arrhythmia recurrence rate after cryoballoon ablation between patients with normal pattern PVs and patients with LCPV. Studies of first ablation for persistent and paroxysmal AF using the 28 mm Arctic Front Advance, Medtronic cryoballoon (CB-A) reporting clinical success rates at a mean follow-up of ≥12 months were included. Data were analyzed by applying a random effects model.ResultsA total of 5 studies with a total of 1178 patients met our predefined inclusion criteria. After a mean follow-up of 18.4 months, the overall success rate of CB-A ablation among patients with persistent and paroxysmal AF was 57%; in the LCPV group the success rate was 46% and in the normal anatomical pattern group it was 61%. No significant heterogeneity was noted among the studies (I2 = 35.8%; Q (df = 3) = 6.23 p-value = 0.18). Arrhythmia recurrence after CB-A ablation was not statistically significant between the two groups (LogOR 0.24; 95% CI [-0.16-0.63]; p-value = 0.23). No significant difference in PNI was observed between the two groups (p-value = 0.693).ConclusionThe presence of LCPV does not affect the long-term outcome of paroxysmal and persistent atrial fibrillation ablation with 28 mm CB-A compared to normal left PVs pattern.  相似文献   

17.
18.
In the egg production industry, trace elements are required as additional dietary supplements to play vital roles in performance and egg quality. Compared to inorganic microelements (ITs), appropriate dose of organic trace microelements (OTs) are environmentally friendly and sufficient to satisfy the needs of hens. In order to evaluate the extent to which low-dose OTs replace whole ITs, the effects of organic copper, zinc, manganese, and iron compound on the performance, eggshell quality, antioxidant capacity, immune function, and mineral deposition of old laying hens were investigated. A total of 1 080 57-week-old Jing Hong laying hens were assigned to five groups with six replicates of 36 layers each for an 8-week experimental period. The birds were fed either a basal diet (control treatment (CT)) or the basal diet supplemented with commercial levels of inorganic trace elements (IT 100%) or the equivalent organic trace elements at 20%, 30%, and 50% of the inorganic elements (OT 20%, OT 30%, and OT 50%, respectively). Results showed that compared with those in the CT treatment, feeding hens with inorganic or organic microelement diet had significant effects on the eggshell quality, antioxidant capacity, immune function, and mineral deposition of old laying hens (P < 0.05). The eggshell strength and ratio between OT 30%, OT 50%, and IT 100% were similar at weeks 4 and 8, and the eggshell thickness of these groups was also similar at weeks 6 and 8. At week 8, the eggshell colour in OT 50% was darker than that in IT 100%. The mineral content in the eggshells of OT 50% and IT 100% significantly increased (P < 0.001), with no significant difference in effective thickness, mammillary thickness, and mammillary knob width between groups. There were no differences in the malondialdehyde content, total antioxidant capacity, and total superoxide dismutase activity in serum between OT 30%, OT 50%, and IT100%. While the catalase activities, the interleukin-1β, interleukin-10, immunoglobulin G, and immunoglobulin M concentrations in serum were not significantly different between OT 50% and IT 100%. The mineral contents in the faeces of the organic groups were considerably reduced compared with those in IT 100% (P < 0.001). In conclusion, dietary supplementation with 30–50% organic compound microelements has the potential to replace 100% inorganic microelements in the hen industry for improving eggshell quality, mineral deposition in the eggshell, antioxidant capacity, and immune function, and reducing emissions to the environment without negative effects on laying performance.  相似文献   

19.
ObjectiveTo examine the learning curves of atrial fibrillation (AF) ablation comparing the cryoballoon (CB) and radiofrequency (RF) catheters.MethodsWe performed a retrospective data analysis from the initiation of AF ablation program in our center. For CB ablation, a second generation 28 mm balloon was utilized and for RF ablation.ResultsA total of 100 consecutive patients (50 in each group) have been enrolled in the study (male 74%, mean age 58.9 ± 10 years, paroxysmal AF 85%). The mean procedure time was shorter for CB (116.6 ± 39.8 min) than RF group (191.8 ± 101.1 min) (p < 0.001). There was no difference in the mean fluoroscopy time, 24.2 ± 10.6 min in RF and 22.4 ± 11.7 min in CB group, (p = 0.422). Seven major complications occurred during the study; 5 in RF group (10%) and 2 in CB group (4%) (p = 0.436). After the mean follow up of 14.5 ± 2.4 months, 15 patients in RF group (30%) and 11 in CB group (26%) experienced AF recurrences (P = 0.300).ConclusionWhen starting a new AF ablation program, our results suggest that CB significantly shortens procedure while fluoroscopy time and clinical outcomes are comparable to RF ablation.  相似文献   

20.

Aims

To evaluate the effects of pulmonary vein isolation (PVI) in terms of feasibility, safety and success rate on a midterm follow-up period in septuagenarians undergoing ablation with the Arctic Front Cryoballoon for atrial fibrillation (AF).

Methods and Results

We prospectively enrolled 21 patients aged 70 years or older (14 male; age 73 ± 2.5 years) elected to circumferential PVI with the 28mm cryoballoon for symptomatic drug resistant paroxysmal AF. A total number of 82 pulmonary veins (PV) were evidenced. Successful isolation could be obtained in all 82 (100%) PV ostia at the end of procedure. No major complication occurred during procedure. At a mean follow-up of 11.5 ± 4.7 months following ablation, 62% of patients did not present recurrence of atrial arrhythmias.

Conclusion

Cryoballoon ablation may be feasible and safe in older patients. Moreover a large proportion of the latter did not present AF recurrence during follow-up.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号