首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In recent years the analysis of heart rate variability (HRV) has become a suitable method for characterizing autonomous cardiovascular regulation. The aim of this study was to investigate the differences in HRV estimated from continuous blood pressure (BP) measurement by different methods in comparison to electrocardiogram (ECG) signals. The beat-to-beat intervals (BBI) were simultaneously extracted from the ECG and blood pressure of 9 cardiac patients (10 min, Colin system, 1000-Hz sampling frequency). For both data types, slope, peak, and correlation detection algorithms were applied. The short-term variability was calculated using concurrent 10-min BP and ECG segments. The root mean square errors in comparison to ECG slope detection were: 1.74 ms for ECG correlation detection; 5.42 ms for ECG peak detection; 5.45 ms for BP slope detection; 5.75 ms for BP correlation detection; and 11.96 ms for BP peak detection. Our results show that the variability obtained with ECG is the most reliable. Moreover, slope detection is superior to peak detection and slightly superior to correlation detection. In particular, for ECG signals with higher frequency characteristics, peak detection often exhibits more artificial variability. Besides measurement noise, respiratory modulation and pulse transit time play an important role in determining BBI. The slope detection method applied to ECG should be preferred, because it is more robust as regards morphological changes in the signals, as well as physiological properties. As the ECG is not recorded in most animal studies, distal pulse wave measurement in combination with correlation or slope detection may be considered an acceptable alternative.  相似文献   

2.
We demonstrate detection of whole viruses and viral proteins with a new label-free platform based on spectral reflectance imaging. The Interferometric Reflectance Imaging Sensor (IRIS) has been shown to be capable of sensitive protein and DNA detection in a real time and high-throughput format. Vesicular stomatitis virus (VSV) was used as the target for detection as it is well-characterized for protein composition and can be modified to express viral coat proteins from other dangerous, highly pathogenic agents for surrogate detection while remaining a biosafety level 2 agent. We demonstrate specific detection of intact VSV virions achieved with surface-immobilized antibodies acting as capture probes which is confirmed using fluorescence imaging. The limit of detection is confirmed down to 3.5 × 10(5)plaque-forming units/mL (PFUs/mL). To increase specificity in a clinical scenario, both the external glycoprotein and internal viral proteins were simultaneously detected with the same antibody arrays with detergent-disrupted purified VSV and infected cell lysate solutions. Our results show sensitive and specific virus detection with a simple surface chemistry and minimal sample preparation on a quantitative label-free interferometric platform.  相似文献   

3.
Recent use of biological warfare (BW) agents has led to a growing interest in the rapid and sensitive detection of pathogens. Therefore, the development of field-usable detection devices for sensitive and selective detection of BW agents is an important issue. In this work, we report a portable biochip system based on complementary metal oxide semiconductor (CMOS) technology that has great potential as a device for single-bacteria detection. The possibility of single-bacteria detection is reported using an immunoassay coupled to laser-induced fluorescence (LIF) detection. Bacillus globigii spores, which are a surrogate species for B. anthracis spores, were used as the test sample. Enzymatic amplification following immunocomplex formation allowed remarkably sensitive detection of B. globigii spores, and could preclude a complicated optical and instrumental system usually required for high-sensitive detection. Atomic force microscopy (AFM) was employed to investigate whether B. globigii spores detected in the portable biochip system exist in single-cell or multicellular form. It was found that B. globigii spores mostly exist in multicellular form with a small minority of single-cell form. The results showed that the portable biochip system has great potential as a device for single-particle or possibly even single-organism detection.  相似文献   

4.
An immunosensor based on surface plasmon resonance imaging (SPR imaging) using a specific monoclonal antibody 11E5 (MAb 11E5) was developed for the detection of the seed-borne bacterium Acidovorax avenae subsp. citrulli (Aac), which causes fruit blotch in watermelons and cantaloupes, and compared to the conventional ELISA technique. The 1:40 mixed self-assembled monolayer (mixed SAM) surface was used for the immobilized MAb 11E5 on sensor surface for the detection of Aac. Both whole cells and broken cells of Aac were tested by using direct and sandwich detection assay. The limit of detection (LOD) of Aac using the SPR imaging technique and a direct detection assay was 10(6)cfu/ml and a subsequent amplification of the SPR signal using a polyclonal antibody (PAb) lowered the LOD to 5×10(5) cfu/ml. The LOD for the ELISA technique was 5×10(4) cfu/ml for the detection of Aac, which was slightly better than that for the SPR technique. However, the sensor surface based on SPR imaging offered a major advantage in terms of surface regeneration, allowing at least five cycles with a shorter time assay, multi-channel analysis with an application on multiplex detection, and an ease of the surface usage for the detection of Aac in the naturally infected plant. The surface was tested against the naturally infected sample and showed good selectivity toward the Aac bacteria.  相似文献   

5.
The role of symmetry detection in early visual processing and the sensitivity of biological visual systems to symmetry across a wide range of organisms suggest that symmetry can be detected by low-level visual mechanisms. However, computational and functional considerations suggest that higher-level mechanisms may also play a role in facial symmetry detection. We tested this hypothesis by examining whether symmetry detection is better for faces than comparable patterns, which share low-level properties with faces. Symmetry detection was better for upright faces than for inverted faces (experiment 1) and contrast-reversed faces (experiment 2), implicating high-level mechanisms in facial symmetry detection. In addition, facial symmetry detection was sensitive to spatial scale, unlike low-level symmetry detection mechanisms (experiment 3), and showed greater sensitivity to a 45 degrees deviation from vertical than is found for other aspects of face perception (experiment 4). These results implicate specialized, higher-level mechanisms in the detection of facial symmetry. This specialization may reflect perceptual learning resulting from extensive experience detecting symmetry in faces or evolutionary selection pressures associated with the important role of facial symmetry in mate choice and 'mind-reading' or both.  相似文献   

6.
A rapid reversed passive latex agglutination method that uses high-density latex particles for the detection of staphylococcal enterotoxins (SE) A to E was developed. It took 3 h for incubation, much less than the 16 h needed with a customary latex agglutination test for SE detection such as a commercial test kit (SET-RPLA; Denka Seiken Co. Ltd., Tokyo, Japan). The rapid test was shown to be highly specific and sensitive for SE detection (detection limit, about 0.5 ng of SE per ml), comparable to the SET-RPLA test. The rapid test was also efficient in SE detection in foods and culture supernatants of staphylococcal strains, similar to the SET-RPLA test. This showed that a rapid test with high-density latex particles is fully reliable for use.  相似文献   

7.
A rapid reversed passive latex agglutination method that uses high-density latex particles for the detection of staphylococcal enterotoxins (SE) A to E was developed. It took 3 h for incubation, much less than the 16 h needed with a customary latex agglutination test for SE detection such as a commercial test kit (SET-RPLA; Denka Seiken Co. Ltd., Tokyo, Japan). The rapid test was shown to be highly specific and sensitive for SE detection (detection limit, about 0.5 ng of SE per ml), comparable to the SET-RPLA test. The rapid test was also efficient in SE detection in foods and culture supernatants of staphylococcal strains, similar to the SET-RPLA test. This showed that a rapid test with high-density latex particles is fully reliable for use.  相似文献   

8.
9.
Trinitrotoluene, usually known as TNT, is a kind of chemical explosive with hazardous and toxic effects on the environment and human health. Ever-increasing needs for a secure society and green environment essentially require the detection of TNT with rapidity, high sensitivity and low cost. In this article, ionic liquid-graphene hybrid nanosheets (IL-GNs) have been used as an enhanced material for rapidly electrochemical detection of trinitrotoluene (TNT). IL-GNs were characterized by atomic force microscopy (AFM), transmission electron microscopy (TEM), X-ray photo-electron spectroscopy, electrochemical impedance spectroscopy, Fourier transform infrared (FT-IR) spectroscopy and Raman spectroscopy, which confirmed that IL has been effectively functionalized on the surface of GNs. Significantly, IL-GNs modified glassy carbon electrode (GCE) showed 6.2 and 51.4-folds higher current signals for TNT reduction than IL-CNTs/GCE and bare GCE, respectively. Adsorptive stripping voltammetry (ASV) for the detection of TNT on IL-GNs exhibited a good linear range from 0.03 to 1.5 ppm with a detection limit of 4 ppb on the basis of the signal-to-noise characteristics (S/N=3). Moreover, IL-GNs/GCE exhibited good stability and reproducibility for the detection of TNT. And, IL-GNs based electrochemical detection platform was also successfully demonstrated for the detection of TNT in ground water, tap water, and lake water with satisfactory results.  相似文献   

10.
Isolation and growth of malignant cells from solid tumors have often met with disappointing results. Consequently, we have developed a cell culture methodology based on ex vivo explantation of tumor tissue, with subsequent monolayer cell outgrowth. In an attempt to assess methods for detection of malignant cells in these cultures, we analyzed and compared the results of cytopathology, growth in soft agar, and detection of telomerase activity with those of standard immunohistochemistry (IHC) techniques for the detection of cytokeratins, tumor marker p53, and proliferation marker Ki-67. The sensitivity of detection of malignant cells was 85% (22/26) for cytopathological examination, 30% (3/10) for soft agar growth, and 100% (12/12) for detection of telomerase activity. From these data, we concluded that both cytopathological examination and assessment of telomerase activity contribute to the detection of malignant cells in primary cultures of human solid tumors, whereas growth in soft agar was not a good indicator of malignant cells. Although not specific for malignant cells per se, IHC detection for epithelial cell cytokeratins showed a high degree of sensitivity (100%, 23/23), whereas the sensitivity for detection of tumor marker p53 and proliferation marker Ki-67 was 30% (7/23) and 70% (16/23), respectively. These data also provide proof that malignant tumor cells, derived from a diverse number of human solid tumors, can be isolated and grown in primary cell culture.  相似文献   

11.
The relationship between detection threshold of inspiratory resistive loads and the peaks of the respiratory-related evoked potential (RREP) is unknown. It was hypothesized that the short-latency and long-latency peaks of the RREP would only be elicited by inspiratory loads that exceeded the detection threshold. The detection threshold for inspiratory resistive loads was measured in healthy subjects with inspiratory-interruption or onset load presentations. In a separate protocol, the RREPs were recorded with resistive loads that spanned the detection threshold. The loads were presented in stimulus attend and ignore sessions. Onset and interruption load presentations had the same resistive load detection threshold. The P(1), N(f), and N(1) peaks of the RREP were observed with loads that exceeded the detection threshold in both attend and ignore conditions. The P(300) was present with loads that exceeded the detection threshold only in the attend condition. No RREP components were elicited with subthreshold loads. The P(1), N(f), and P(300) amplitudes varied with resistive load magnitude. The results support the hypothesis that there is a resistive load threshold for eliciting the RREPs. The amplitude of the RREP peaks vary as a function of load magnitude. The cognitive P(300) RREP peak is present only for detectable loads and when the subject attends to the stimulus. The absence of the RREP with loads below the detection threshold and the presence of the RREP elicited by suprathreshold loads are consistent with the gating of these neural measures of respiratory mechanosensory information processing.  相似文献   

12.
Analysis of data from point counts, a common method for monitoring bird population trends, has evolved to produce estimates of various population parameters (e.g., density, abundance, and occupancy) while simultaneously estimating detection probability. An important consideration when designing studies using point counts is to maximize detection probability while minimizing variation in detection probability both within and between counts. Our objectives were to estimate detection probabilities for three marsh songbirds, including Marsh Wrens (Cistothorus palustris), Swamp Sparrows (Melospiza georgiana), and Yellow‐headed Blackbirds (Xanthocephalus xanthocephalus), as a function of weather covariates and to evaluate temporal variability in detection probability of these three species. We conducted paired, unlimited radius, 10‐min point counts during consecutive morning and evening survey periods for our three focal species at 56 wetlands in Iowa from 20 April to 10 July 2010. Mean detection probabilities ranged from 0.272 (SE = 0.042) for Marsh Wrens to 0.365 (SE = 0.052) for Swamp Sparrows. Time of season was positively correlated with detection probability for Swamp Sparrows, but was negatively correlated with detection probability for Yellow‐headed Blackbirds, suggesting that detection probability increased during the breeding season for Swamp Sparrows and was highest early in the breeding season for Yellow‐headed Blackbirds. Understanding how detection probabilities of marsh songbirds vary throughout the breeding season allows targeted survey efforts that maximize detection probabilities for these species. Furthermore, consistent detection probabilities of marsh songbirds during morning and evening survey periods mean that investigators have more time to conduct surveys for these birds, allowing greater flexibility to increase spatial and temporal replication of surveys that could provide more precise estimates of desired population parameters.  相似文献   

13.
Estimating range-wide population trends of western burrowing owls (Athene cunicularia) requires standardized survey protocols that correct for detection bias in environments that support large owl populations. High concentrations of owls exist in irrigated agroecosystems within the southwest United States, yet little is known about the factors that affect detection bias during owl surveys in these systems. I used closed-population capture-recapture models to evaluate 4 factors that could affect the probability of a surveyor detecting an owl activity center (i.e., nest burrow) during visual surveys where owls are the focal object and analyzed the relationship (linear or curvilinear) between specific factors and detection probability. I recorded 1,199 detections of owls from 132 capture-recapture surveys within 12 sites of the Imperial Valley agroecosystem in California, USA between 16 April and 20 May 2006. I also conducted 96 time budget surveys throughout the day and used mixed linear models to evaluate the effect of each factor on probability of an owl activity center being available for detection (i.e., ≥1 owls above ground) during surveys. Model selection results indicated that detection probability was influenced by ambient air temperature interacting with wind speed. Detection probability followed a curvilinear relationship that resembled bell-shaped curve along a temperature gradient, with the maximum detection probability shifting as a function of wind speed. At low temperatures, detection probability declined with increased wind speed, but this relationship was reversed at high temperatures, producing a 3-dimensional pattern in detection probability characterized by a saddle-shaped hyperbolic paraboloid response surface. The probability of an activity center being available for detection declined curvilinearly with increased temperature and explained 51% of the variation in detection probability. Given the broad range of detection probabilities, correcting visual survey counts for detection bias is necessary for comparing population estimates among regions and through time. Survey designs intended to estimate abundance of owls in southwest agroecosystems should incorporate methods to estimate and correct for variation in detection probability that include measurements of ambient temperature and wind speed for use as covariates. © 2011 The Wildlife Society.  相似文献   

14.
核酸检测作为新型冠状病毒肺炎(COVID-19)筛查诊断和病情监测的主要手段,在疫情防控中发挥了重要作用。虽然实时荧光定量PCR被认为是新型冠状病毒(SARS-CoV-2)核酸检测的金标准,但其依赖荧光定量PCR仪且扩增检测时间较长,难以实现现场快速检测。因此许多基于核酸等温扩增的SARS-CoV-2检测方法相继诞生。等温扩增对仪器温控要求不高,通过与微流控芯片和可视化检测技术结合,可进一步简化操作、降低成本,为SARS-CoV-2现场快速筛查提供有力的技术支撑。本文围绕已报道的SARS-CoV-2等温扩增检测方法原理、检测性能及优缺点进行探讨,为进一步发展SARS-CoV-2现场快速检测平台提供参考。  相似文献   

15.
A pathogen detection methodology based on Bayesian decision theory has been developed for rapid and reliable detection of Salmonella typhimurium. The methodology exploits principles from statistical signal processing along with impedance spectroscopy in order to analytically determine the existence of pathogens in the target solution. The proposed technique is validated using a cost-effective and portable immunosensor. This device uses label-free, electrochemical impedance spectroscopy for pathogen detection and has been demonstrated to reliably detect pre-infectious levels of pathogen in sample solutions. The detection process does not entail any pathogen enrichment procedures. The results using the proposed technique indicate a detection time of approximately 6min (5min for data acquisition, 1min for analysis) for pathogen concentrations in the order of 500CFU/ml. The detection methodology presented here has demonstrated high accuracy and can be generalized for the detection of other pathogens with healthcare, food, and environmental implications. Furthermore, the technique has a low computational complexity and uses a minimal data-set (only 30 data-samples) for data analysis. Hence, it is ideal for use in hand-held pathogen detectors.  相似文献   

16.
Chemiluminescence generated with the reaction of bis(2,4,6-trichlorophenyl)oxalate and hydrogen peroxide was applied to a detection system for high-performance liquid chromatography to determine fluorescamine-labeled catecholamines. The sensitivity of the chemiluminescence detection system with 25 fmol of detection limit was approximately 20 times higher than that of a conventional fluorescence detection system. Norepinephrine and dopamine in human urine were determined by the use of the new high-performance liquid chromatography detection system with the coefficient of variation of less than 4.0%. Good correlations (r = 0.998 for norepinephrine and r = 0.999 for dopamine) were obtained between the values by the present method and the conventional method.  相似文献   

17.
A novel enzyme-linked DNA hybridization assay on an interdigitated array (IDA) microelectrode integrated into a microfluidic channel is demonstrated with sub-nM detection limit. To improve the detection limit as compared to conventional electrochemical biosensors, a recyclable redox product, 4-aminophenol (PAP) is used with an IDA microelectrode. The IDA has a modest and easily fabricated inter-digit spacing of 10 μm, yet we were able to demonstrate 97% recycling efficiency of PAP due to the integration in a microfluidic channel. With a 70 nL sample volume, the characterized detection limit for PAP of 1.0 × 10?1? M is achieved, with a linear dynamic range that extends from 1.0 × 10?? to 1.0 × 10?? M. This detection limit, which is the lowest reported detection limit for PAP, is due to the increased sensitivity provided by the sample confinement in the microfluidic channel, as well as the increased repeatability due to perfectly static flow in the microchannel and an additional anti-fouling step in the protocol. DNA sequence detection is achieved through a hybridization sandwich of an immobilized complementary probe, the target DNA sequence, and a second complementary probe labeled with β-galactosidase (β-GAL); the β-GAL converts its substrate, 4-aminophenyl-d-galactopyranoside (PAPG), into PAP. In this report we present the lowest reported observed detection limit (1.0 × 10?1? M) for an enzyme-linked DNA hybridization assay using an IDA microelectrode and a redox signaling paradigm. Thus, we have demonstrated highly sensitive detection of a targeted DNA sequence using a low-cost easily fabricated electrochemical biosensor integrated into a microfluidic channel.  相似文献   

18.
The potential of aptamers as ligand binding molecule has opened new avenues in the development of biosensors for cancer oncoproteins. In this paper, a label-free detection strategy using signaling aptamer/protein binding complex for platelet-derived growth factor (PDGF-BB) oncoprotein detection is reported. The detection mechanism is based on the release of fluorophore (TOTO intercalating dye) from the target binding aptamer's stem structure when it captures PDGF. Amino-terminated three-dimensional carbon microarrays fabricated by pyrolyzing patterned photoresist were used as a detection platform. The sensor showed near linear relationship between the relative fluorescence difference and protein concentration even in the sub-nanomolar range with an excellent detection limit of 5pmol. This detection strategy is promising in a wide range of applications in the detection of cancer biomarkers and other proteins.  相似文献   

19.
The current sensitivity of standard fluorescence-based protein detection limits the use of protein arrays in research and clinical diagnosis. Here, we use functionalized, macromolecular single-walled carbon nanotubes (SWNTs) as multicolor Raman labels for highly sensitive, multiplexed protein detection in an arrayed format. Unlike fluorescence methods, Raman detection benefits from the sharp scattering peaks of SWNTs with minimal background interference, affording a high signal-to-noise ratio needed for ultra-sensitive detection. When combined with surface-enhanced Raman scattering substrates, the strong Raman intensity of SWNT tags affords protein detection sensitivity in sandwich assays down to 1 fM--a three-order-of-magnitude improvement over most reports of fluorescence-based detection. We use SWNT Raman tags to detect human autoantibodies against proteinase 3, a biomarker for the autoimmune disease Wegener's granulomatosis, diluted up to 10(7)-fold in 1% human serum. SWNT Raman tags are not subject to photobleaching or quenching. By conjugating different antibodies to pure (12)C and (13)C SWNT isotopes, we demonstrate multiplexed two-color SWNT Raman-based protein detection.  相似文献   

20.
Traditional assays for secreted proteins include methods such as Western blot and enzyme-linked immunosorbent assay (ELISA) detection of the protein in the cell culture medium. We describe a method for the detection of a secreted protein based on fluorescent measurement of an mCherry fusion reporter. This microplate reader-based mCherry fluorescence detection method has a wide dynamic range of 4.5 orders of magnitude and a sensitivity that allows detection of 1 to 2 fmol fusion protein. Comparison with the Western blot detection method indicated greater linearity, wider dynamic range, and a similar lower detection threshold for the microplate-based fluorescent detection assay of secreted fusion proteins. An mCherry fusion protein of matrix metalloproteinase-9 (MMP-9), a secreted glycoprotein, was created and expressed by transfection of human embryonic kidney (HEK) 293 cells. The cell culture medium was assayed for the presence of the fluorescent signal up to 32 h after transfection. The secreted MMP-9–mCherry fusion protein was detected 6 h after transfection with a linear increase in signal intensity over time. Treatment with chloroquine, a drug known to inhibit the secretion of many proteins, abolished the MMP-9–mCherry secretion, demonstrating the utility of this method in a biological experiment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号