首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Three serologic test methods for detection of serum antibodies to mouse thymic virus (MTV) were compared, including enzyme-linked immunosorbent assay (ELISA), complement fixation (CF) test and indirect fluorescent antibody (IFA) test. Serum was collected at regular intervals from CD-1 mice inoculated intraperitoneally with approximately 200 infectious doses of MTV, and from uninoculated mice placed in cages with the inoculated animals. The inoculated mice became MTV antibody-positive by all three assay methods at 15 days post inoculation, while the cage-contacts were seropositive by all methods at 30 days after contact. Although the incidence of positive results was similar by all methods, titers measured by ELISA were substantially higher than those measured by CF and IFA tests. Because MTV can cause persistent infections that adversely affect the suitability of mice for research, it is recommended that testing for antibodies to this virus be performed routinely.  相似文献   

3.
4.
Sixty-one serum samples selected on the basis of reactivity in the complement fixation (CF) and latex agglutination (LA) test, were further examined for sensitivity and specificity by indirect haemagglutination (IHA), enzyme linked immunosorbent assay (ELISA) and defined antigen substrate spheres (DASS). Twenty sera from healthy Europeans and 48 samples from patients with either schistosomiasis or trichinosis were also tested. Comparable levels of sensitivity were found between the CF and LA positive sera and IHA, ELISA and DASS. Of the CF positive LA negative group of sera, many were positive by DASS but only a few reacted in IHA and ELISA. Some cross reactivity was also observed in the schistosomiasis sera tested by IHA and ELISA.  相似文献   

5.
The authors describe the preparation of a first batch of intravenous cytomegalovirus (CMV) immune globulin at the Nancy Regional blood transfusion centre. Immune plasmas were selected from 3 640 healthy volunteer blood donors on the basis of CF antibody titers to CMV (Kolmer's method modified) of, at least, 1:8; plasmas from approximately 10% of the donors were therefore selected. The 68 liters of pooled immune plasma had à CF antibody titer of 1:16 (CMV antibody titers of 1: 10 000 and 1: 640 when tested in the ELISA assay and passive hemagglutination assay respectively). Intravenous immune globulin was produced from pooled plasma by Cohn fractionation and treatment with pepsin at pH 4; 4.8 liters of immune globulin were prepared and divided in 96 doses of 50 ml each. The final product was found to have a CMV antibody titer of 1: 32 (CF) 1: 50 000 (ELISA) or 1: 2 560 (passive hemagglutination). Recent reports on the preparation of CMV immune globulin are briefly reviewed.  相似文献   

6.
Toxoplasmosis has been well known as an important human infection to consider especially in pregnant women. Although many serologic methods are available, the diagnosis of toxoplasmosis can be extremely difficult. The presence of increased levels of Toxoplasma-specific IgG antibodies indicates an infection, but it does not differentiate between a recent and past infection. The purpose of our study was to compare the performance of the ELISA T. gondii IgG/IgM test, a widely used enzyme-linked immunosorbent assay, to the ELISA IgG avidity method. One hundred and four serum samples (from 38 males and 66 females) were tested and evaluated from symptomatic patients (chorioretinitis, lymphadenopathy), and from women in their first trimester of pregnancy who were suspected of having toxoplasmosis. The high IgG avidity and ELISA IgG antibody levels were in agreement for 51 of the specimens (49.0%). Thirty-eight discrepant (borderline) results from the IgG avidity method were positive for IgM (3 specimens) and IgG (37 specimens). Interestingly, out of the eight serum samples that were positive for both IgG and IgM antibodies, two samples were low IgG avidity, and three samples were borderline. There was no statistically significant relation observed between the results of the IgG avidity method and the ELISA IgG test, and the IgG avidity method and ELISA IgM test (chi2 = 1.987; p = 0.370 and chi2 = 2.152; p = 0.341, respectively). The IgG avidity method was considered easy to perform and an acceptable approach for the differentiation of discrepant results (recent/chronic) and for the current detection of T. gondii antibodies. We concluded that the determination of IgG avidity is a helpful tool for the diagnosis of the ocular form of toxoplasmosis and it is a safe method for screening this disease in the first trimester of pregnancy.  相似文献   

7.
Two procedures have been used for measuring antibody titres to bovine herpes virus 1 (BHV1): the serum neutralization (SN) test and enzyme-linked immunosorbent assay (ELISA). One hundred and thirty-two sera selected for their low SN titres were tested both unadsorbed and after adsorption with kaolin to determine the effect of kaolin on the titres. With ELISA, the titres of unadsorbed and kaolin adsorbed were not significantly different but with the SN test many treated sera, originally with weak positive titres, became negative after kaolin adsorption. Thus, if the ELISA results are specific for BHV1 antibody then the SN test findings suggest that treatment of sera with kaolin, rather than removing a viral inhibitor, removes a substance from the serum which potentiates SN antibody. This in turn indicates that low SN titres (reciprocal of titre less than or equal to 4, for instance) are probably specific for BHV1 SN antibody whether or not they are abolished by kaolin treatment of the serum.  相似文献   

8.
Sensitivity of anti-Toxoplasma antibody (IgG) test by enzyme-linked immunosorbent assay (ELISA) was evaluated in comparison with indirect latex agglutination (ILA) using 2,016 paired human samples of serum and cerebrospinal fluid (CSF). The samples were collected from neurologic patients in Korea with mass lesions in central nervous system (CNS) as revealed by imaging diagnosis (CT/MRI). When the sera were screened for anti-Toxoplasma antibody by ILA, 76 cases(3.8%) were positive (1:32 or higher titers). In the paired samples of CSF, no positive reactions were observed. When ELISA was performed using PBS extract of Percoll purified tachyzoites as antigen, cut-off absorbance was determined as 0.40 for serum and 0.27 for CSF tests. The antibody positive rates by ELISA were 7.0% in serum and 5.6% in CSF. Of them, 40 cases (2.0%) showed positive reactions in both serum and CSF. The antibody positive rates were higher in groups older than 40 years. The rates were higher in male (4.7% by ILA, 8.3% by ELISA) than in female (2.2% by ILA, 5.0% by ELISA). The rates in CSF showed no such sex difference. ELISA showed twice higher positive rates when serum was tested, and was sensitive enough to detect specific antibodies in CSF. Etiologic relations between positive antibody tests and CNS lesions remained unknown.  相似文献   

9.
目的了解孕期妇女麻疹抗体水平,为麻疹免疫策略提供依据。方法2005-2006年,在德州市随机抽取部分地区20-38岁孕期妇女进行血清麻疹IgG抗体检测。结果检测702人,麻疹IgG抗体阳性率为84.33%,保护率为37.75%,抗体几何平均滴度(GMT)为1:176.81。不同地区麻疹抗体阳性率和GMT的差异均有统计学意义(P〈0.01);GMT呈现随年龄增长而增加的趋势(P〈0.05)。结论德州市孕期妇女麻疹IgG抗体水平较低。  相似文献   

10.
捕捉法ELISA检测流行性乙型脑炎IgM抗体用于早期快速诊断   总被引:3,自引:1,他引:2  
张礼壁  刘玉清 《病毒学报》1989,5(4):378-382
  相似文献   

11.
应用ELISA直接双抗体夹心法检查轮状病毒抗原,24份仔猪和29份犊牛的腹泻粪样,分别有12和16份阳性。用病毒RNA电泳分析检查阳性粪样,各出现两种病毒RNA电泳型,用中和试验检查17份成年牛和16份成年猪血清,分别有16和15份病毒抗体阳性。将其与ELISA间接法和结合法进行了比较。  相似文献   

12.
The enzyme-linked immunosorbent assay (ELISA) has been used for detection of antibodies against Mycoplasma pneumoniae. The results of ELISA and its sensitivity compared with other serological methods, such as complement fixation (CF), metabolic inhibition (MI), mycoplasmacidal test (MC), and radioimmunoprecipitation (RIP) are reported. ELISA and MC showed greater sensitivity than CF and MI, while RIP showed serum titer two- to 16-fold higher. ELISA was specific as determined using other human mycoplasma. A simplified method based on the determination of ELISA antibody end-point titer by a single serum dilution has been proposed. ELISA presented several advantages: sensitivity, rapidity, and low cost and, if adequately standardized, could become a reliable method for the serodiagnosis of M. pneumoniae infection.  相似文献   

13.
PURPOSE: To determine levels of the chemokines CCL1/I-309, CCL2/MCP-1, CCL3/MIP-1alpha, CCL4/MIP-1beta, CCL7/MCP-3, CCL8/MCP-2, CXCL5/ENA-78, CXCL6/GCP-2, CXCL10/IP-10, and CXCL11/I-TAC in the vitreous humor and serum, from patients with proliferative diabetic retinopathy (PDR), proliferative vitreoretinopathy (PVR), and rhegmatogenous retinal detachment with no PVR (RD), and to investigate the expression of MCP-1, CXCL12/SDF-1, and the chemokine receptor CXCR3 in epiretinal membranes. METHODS: Paired vitreous humor and serum samples were obtained from patients undergoing vitrectomy for the treatment of RD (57 specimens), PVR (32 specimens), and PDR (88 specimens). The levels of chemokines were measured by enzyme-linked immunosorbent assays. Eighteen PDR and 5 PVR membranes were studied by immunohistochemical techniques. RESULTS: Of all the chemokines studied, only MCP-1 and IP-10 were detected in vitreous humor samples. MCP-1 levels in vitreous humor samples were significantly higher than in serum samples (p < 0.001). MCP-1 levels were significantly higher in vitreous humor samples from patients with PVR and PDR compared with RD (p = 0.0002). MCP-1 levels in vitreous humor samples from patients with active PDR were significantly higher than in inactive PDR cases (p = 0.0224). IP-10 levels in vitreous humor samples were significantly higher than in serum samples (p = 0.0035). IP-10 levels were significantly higher in vitreous humor samples from patients with PVR and PDR compared with RD (p = 0.0083). The incidence of IP-10 detection in vitreous humor samples was significantly higher in active PDR cases compared with inactive cases (p = 0.0214). There was a significant association between the incidence of IP-10 detection and increased levels of MCP-1 in vitreous humor samples from all patients, and patients with RD and PDR (p < 0.001 for all comparisons). MCP-1, and SDF-1 were localized in myofibroblasts in PVR and PDR membranes and in vascular endothelial cells in PDR membranes. CXCR3 was expressed by vascular endothelial cells in PDR membranes. CONCLUSION: MCP-1, IP-10 and SDF-1 may participate in pathogenesis of PVR and PDR. Myofibroblasts and vascular endothelial cells are the major cell types expressing MCP-1, SDF-1, and CXCR3 in epiretinal membranes.  相似文献   

14.
Serum samples from 58 Pacific bottlenose dolphins (Tursiops aduncus) from the Solomon Islands were tested for the IgG antibody to Toxoplasma gondii by the latex agglutination test (LAT), enzyme-linked immunosorbent assay (ELISA), and immunoblotting. The ELISA cut-off value was taken as OD > or = 0.276, and the final dilution ratio, recognized as positive, was represented by the end titer. In 25 of 58 samples, no antibody activity was detected by LAT and ELISA. In 8 of 58 samples, anti-T. gondii IgG antibodies were detected by both LAT and ELISA, with titers of greater than 1 : 64 and 1 : 160, respectively. By immunoblotting, the 8 serum samples producing higher titers showed specific antibody IgG binding to several antigens on the T. gondii lane, but not on the Neospora caninum lane. No specific bands were noted on the lanes for either parasite in the 25 serum samples for which no antibody activity was detected. The specific binding of IgG antibodies to T. gondii antigens observed for serum samples producing higher titers suggests that Pacific bottlenose dolphins from the Solomon islands are exposed to T. gondii.  相似文献   

15.
Detection of serum antibodies against Chlamydia pneumoniae by ELISA   总被引:3,自引:0,他引:3  
Abstract Chlamydia pneumoniae causes pneumonia and other respiratory infections in children, adolescents and adults. We tried to evaluate the diagnostic value of detection of serum antibodies by ELISA for C. pneumoniae infections in Japanese children. Serum IgG, IgA and IgM antibodies to C. pneumoniae were determined by the microimmunofluorescence (MIF) test. Serum IgG and IgA antibodies were also determined by ELISA test kits. Results obtained by ELISA were compared with those obtained by MIF test. IgG antibody to C. pneumoniae was detected in 135 (39.5%) by ELISA and in 125 (36.5%) by MIF out of 342 sera from Japanese infants and children without respiratory infections (aged from 2 months old to 15 years old). IgA antibody to C. pneumoniae was detected in 129 (37.7%) by ELISA and in 117 (34.2%) by MIF out of 342 sera tested. Of 342 specimens 113 were IgG-positive by ELISA and MIF (sensitivity: 90.4%, specificity: 89.9%, r = 0.853). Of 342 sera 28 had IgG antibody titers of 1:256 and none had titers 1:512 or higher by MIF. Of 28 infants and children a total of nine were less than 4 years of age. On the other hand, of 342 specimens 99 were IgA-positive by ELISA and MIF (sensitivity: 84.6%, specificity: 86.7%, r = 0.769). Of 342 sera 16 had IgA antibody titers of 1:256 or higher by MIF. Of 16 infants and children, ten were less than 4 years of age. ELISA had excellent sensitivity and specificity relative to MIF test for detection of IgC and IgA antibodies to C. pneumoniae . It was suggested that C. pneumoniae infection in Japanese infants and children under 4 years of age was not infrequent.  相似文献   

16.
The usefulness of the ELISA using as antigen prepared in our laboratory supernatant obtained after centrifugation of sonicated F. tularensis cell suspension was compared with the tube agglutination test with commercial available antigen. Paired serum specimens obtained from 6 patients with ulceroglandular syndrome of tularemia were tested in both tests. The cut-off limit of serum antibodies was set at mean antibody titre determined in the sera of 115 blood donors exceeded by three standard deviations. Antibodies to F. tularensis in diagnostically significant titre were detected in all 12 serum samples by both tests. However the titres obtained in ELISA were several times higher than in tube agglutination test. In the second serum sample the level of IgA and IgM was lower but the level of IgG higher than in the first sample. We could not observe any difference in the level of antibodies between paired serum specimens in tube agglutination test.  相似文献   

17.
AIMS: To develop a competitive agglutination inhibition assay (CAIA) for the detection of anti-Toxic Shock Syndrome Toxin-1 (TSST-1) antibody in serum samples using a commercially available reverse passive agglutination assay (RPLA) kit. METHODS AND RESULTS: TSST-1 toxin and sera were incubated together, so that anti-toxin IgG would complex with the toxin. Latex particles sensitized with rabbit IgG anti-TSST-1 were added to test for un-complexed toxin. The sensitivity and specificity of the CAIA assay was determined relative to positive and negative ELISA results. The sensitivity (proportion of positive ELISA sera which tested positive by CAIA) was 66% whilst the specificity (proportion of ELISA negative sera which tested negative by CAIA) was 75%. Seven sera (14%) were negative by ELISA but positive for CAIA and 12 (18.8%) were positive for ELISA but negative for CAIA, suggesting some interference with the assays. Statistical analysis showed no significant difference between the methods in terms of the numbers of individuals testing positive (chi2, P = 0.04). CONCLUSIONS: The CAIA assay allowed detection of anti-TSST-1 within 18 h and was simple to read visually. SIGNIFICANCE AND IMPACT OF THE STUDY: The method is a useful test for individual serum samples and a preliminary investigation for medical screening of suspected toxic shock syndrome and is applicable in situations where antibody assays are not routinely used for anti-TSST-1 and also where sophisticated equipment (e.g. microtitre plate reader) is not available.  相似文献   

18.
用ELISA、间接免疫荧光和中和试验三种方法测定兔免疫血清的呼吸道合胞病毒抗体。结果中和试验测定的免疫血清几何平均抗体滴度为1:32;间接免疫荧光试验为1:508,比中和试验高16倍;ELISA测得的抗体滴度1:4,000~1:5,000,为中和试验的125~156倍。以ELISA敏感性最高,间接免疫荧光试验次之,中和试验景差。  相似文献   

19.
The usefulness of Serodia-Myco II agglutination test (Fujirebio, Japan) for diagnosis of the M. pneumoniae infections was evaluated. A total of 66 serum samples obtained from patients with respiratory tract infections were tested by Serodia-Myco II test, complement fixation (CF) test, ELISA-IgG/-IgM, and by latex agglutination (LA) test prepared in our laboratory. Using CF test and ELISA as the reference tests, Serodia-Myco II test gave too many false positive results. This test in relation to CF test, ELISA-IgM, ELISA-IgG, and LA test showed a very high sensitivity, virtually 100%, with a low specificity, below 50%. It seems that oversensitivity of the Serodia-Myco II test is caused by too low cut off (40) value recommended by the manufacturer. The Serodia-Myco II test may be used in routine serodiagnosis of mycoplasmosis under condition that cut off value will be raised to 160 and the positive results of this test will be confirmed by the CF test or ELISA.  相似文献   

20.
The results of CF and ELISA tests for cytomegalovirus performed on 270 sera of hospitalized patients show a positive correlation. As a general rule, ELISA is more sensitive than CF, except for a few sera collected from patients with immunological disorders. When two sequential sera are available, the CF remains a reliable and inexpensive method. But when only one serum can be obtained, the probability of an active CMV infection can be estimated on the IgM/IgG ratio. In 26% of the patients, this ratio was greater than or equal to 1. The ELISA is twice as expensive as the CF test. To reduce its cost, a simple method for preparing ELISA antigen from commercially-obtained CF antigens is described.  相似文献   