首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation.

Methodology/Principal Findings

Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R2 = 0.96. Bland-Altman analysis showed a bias of −1.07±24.71 ml and limits of agreement of −49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R2 values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT.

Conclusions/Significance

Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT.  相似文献   

2.
The assessment of the regional match between alveolar ventilation and perfusion in critically ill patients requires simultaneous measurements of both parameters. Ideally, assessment of lung perfusion should be performed in real-time with an imaging technology that provides, through fast acquisition of sequential images, information about the regional dynamics or regional kinetics of an appropriate tracer. We present a novel electrical impedance tomography (EIT)-based method that quantitatively estimates regional lung perfusion based on first-pass kinetics of a bolus of hypertonic saline contrast. Pulmonary blood flow was measured in six piglets during control and unilateral or bilateral lung collapse conditions. The first-pass kinetics method showed good agreement with the estimates obtained by single-photon-emission computerized tomography (SPECT). The mean difference (SPECT minus EIT) between fractional blood flow to lung areas suffering atelectasis was -0.6%, with a SD of 2.9%. This method outperformed the estimates of lung perfusion based on impedance pulsatility. In conclusion, we describe a novel method based on EIT for estimating regional lung perfusion at the bedside. In both healthy and injured lung conditions, the distribution of pulmonary blood flow as assessed by EIT agreed well with the one obtained by SPECT. The method proposed in this study has the potential to contribute to a better understanding of the behavior of regional perfusion under different lung and therapeutic conditions.  相似文献   

3.
In this project we evaluate the dynamic changes during expiration at different levels of positive-end-expiratory pressure (PEEP) in ventilated patients. We wanted to discriminate between normal lung function and acute respiratory distress syndrome (ARDS). After approval by the local Ethic Committee we studied two ventilated patients: (one with normal lung function and one with ARDS) We used the 50 ms scan mode of the EBCT. The beam was positioned 1 cm above the diaphragm while the table position remained unchanged. We developed an electronic trigger that utilizes the respirator's synchronizing signal to start the EBCT at the onset of expiration. During controlled mechanical expiration at two levels of PEEP (0 and 15 cm H2O), pulmonary aeration was rated as: well-aerated (-900HU to -500HU), poorly aerated (-500HU to -100HU) and non-aerated (-100HU to +100HU). Pathological and normal lung functions showed different dynamic changes. The different PEEP levels resulted in a significant change of pulmonary aeration in the same patient. Although we studied only two patients, respiratory triggered EBCT may be accurate in discriminating pathological changes due to the abnormal lung function in a mechanically ventilated patient.  相似文献   

4.

Introduction

Lung-protective ventilation aims at using low tidal volumes (VT) at optimum positive end-expiratory pressures (PEEP). Optimum PEEP should recruit atelectatic lung regions and avoid tidal recruitment and end-inspiratory overinflation. We examined the effect of VT and PEEP on ventilation distribution, regional respiratory system compliance (CRS), and end-expiratory lung volume (EELV) in an animal model of acute lung injury (ALI) and patients with ARDS by using electrical impedance tomography (EIT) with the aim to assess tidal recruitment and overinflation.

Methods

EIT examinations were performed in 10 anaesthetized pigs with normal lungs ventilated at 5 and 10 ml/kg body weight VT and 5 cmH2O PEEP. After ALI induction, 10 ml/kg VT and 10 cmH2O PEEP were applied. Afterwards, PEEP was set according to the pressure-volume curve. Animals were randomized to either low or high VT ventilation changed after 30 minutes in a crossover design. Ventilation distribution, regional CRS and changes in EELV were analyzed. The same measures were determined in five ARDS patients examined during low and high VT ventilation (6 and 10 (8) ml/kg) at three PEEP levels.

Results

In healthy animals, high compared to low VT increased CRS and ventilation in dependent lung regions implying tidal recruitment. ALI reduced CRS and EELV in all regions without changing ventilation distribution. Pressure-volume curve-derived PEEP of 21±4 cmH2O (mean±SD) resulted in comparable increase in CRS in dependent and decrease in non-dependent regions at both VT. This implied that tidal recruitment was avoided but end-inspiratory overinflation was present irrespective of VT. In patients, regional CRS differences between low and high VT revealed high degree of tidal recruitment and low overinflation at 3±1 cmH2O PEEP. Tidal recruitment decreased at 10±1 cmH2O and was further reduced at 15±2 cmH2O PEEP.

Conclusions

Tidal recruitment and end-inspiratory overinflation can be assessed by EIT-based analysis of regional CRS.  相似文献   

5.
ABSTRACT: BACKGROUND: Hyperpolarised helium MRI (He3 MRI) is a new technique that enables imaging of the air distribution within the lungs. This allows accurate determination of the ventilation distribution in vivo. The technique has the disadvantages of requiring an expensive helium isotope, complex apparatus and moving the patient to a compatible MRI scanner. Electrical impedance tomography (EIT) a non-invasive bedside technique that allows constant monitoring of lung impedance, which is dependent on changes in air space capacity in the lung. We have used He3MRI measurements of ventilation distribution as the gold standard for assessment of EIT. METHODS: Seven rats were ventilated in supine, prone, left and right lateral position with 70% helium/30% oxygen for EIT measurements and pure helium for He3 MRI. The same ventilator and settings were used for both measurements. Image dimensions, geometric centre and global in homogeneity index were calculated. RESULTS: EIT images were smaller and of lower resolution and contained less anatomical detail than those from He3 MRI. However, both methods could measure positional induced changes in lung ventilation, as assessed by the geometric centre. The global in homogeneity index were comparable between the techniques. CONCLUSION: EIT is a suitable technique for monitoring ventilation distribution and inhomgeneity as assessed by comparison with He3 MRI.  相似文献   

6.
Adler, A., R. Amyot, R. Guardo, J. H. T. Bates, and Y. Berthiaume. Monitoring changes in lung air and liquid volumes withelectrical impedance tomography. J. Appl.Physiol. 83(5): 1762-1767, 1997.Electricalimpedance tomography (EIT) uses electrical measurements at electrodesplaced around the thorax to image changes in the conductivitydistribution within the thorax. This technique is well suited tostudying pulmonary function because the movement of air, blood, andextravascular fluid induces significant conductivity changes within thethorax. We conducted three experimental protocols in a total of 19 dogsto assess the accuracy with which EIT can quantify changes in thevolumes of both gas and fluid in the lungs. In the first protocol, lungvolume increments from 50 to 1,000 ml were applied with a largesyringe. EIT measured these volume changes with an average error of 27 ± 6 ml. In the second protocol, EIT measurements were made at endexpiration and end inspiration during regular ventilation with tidalvolume ranging from 100 to 1,000 ml. The average error in the EITestimates of tidal volume was 90 ± 43 ml. In the third protocol,lung liquid volume was measured by instilling 5% albumin solution intoa lung lobe in increments ranging from 10 to 100 ml. EIT measured thesevolume changes with an average error of 10 ± 10 ml and was alsoable to detect into which lobe the fluid had been instilled. These results indicate that EIT can noninvasively measure changes in thevolumes of both gas and fluid in the lungs with clinically usefulaccuracy.

  相似文献   

7.

Background

Hyperpolarised helium MRI (He3 MRI) is a new technique that enables imaging of the air distribution within the lungs. This allows accurate determination of the ventilation distribution in vivo. The technique has the disadvantages of requiring an expensive helium isotope, complex apparatus and moving the patient to a compatible MRI scanner. Electrical impedance tomography (EIT) a non-invasive bedside technique that allows constant monitoring of lung impedance, which is dependent on changes in air space capacity in the lung. We have used He3MRI measurements of ventilation distribution as the gold standard for assessment of EIT.

Methods

Seven rats were ventilated in supine, prone, left and right lateral position with 70% helium/30% oxygen for EIT measurements and pure helium for He3 MRI. The same ventilator and settings were used for both measurements. Image dimensions, geometric centre and global in homogeneity index were calculated.

Results

EIT images were smaller and of lower resolution and contained less anatomical detail than those from He3 MRI. However, both methods could measure positional induced changes in lung ventilation, as assessed by the geometric centre. The global in homogeneity index were comparable between the techniques.

Conclusion

EIT is a suitable technique for monitoring ventilation distribution and inhomgeneity as assessed by comparison with He3 MRI.  相似文献   

8.
ABSTRACT: The measurement of ventilation distribution is currently performed using inhaled tracer gases for multiple breath inhalation studies or imaging techniques to quantify spatial gas distribution. Most tracer gases used for these studies have properties different from that of air. The effect of gas density on regional ventilation distribution has not been studied. This study aimed to measure the effect of gas density on regional ventilation distribution. METHODS: Ventilation distribution was measured in seven rats using electrical impedance tomography (EIT) in supine, prone, left and right lateral positions while being mechanically ventilated with either air, heliox (30% oxygen, 70% helium) or sulfur hexafluoride (20% SF6, 20% oxygen, 60% air). The effect of gas density on regional ventilation distribution was assessed. RESULTS: Gas density did not impact on regional ventilation distribution. The non-dependent lung was better ventilated in all four body positions. Gas density had no further impact on regional filling characteristics. The filling characteristics followed an anatomical pattern with the anterior and left lung showing a greater impedance change during the initial phase of the inspiration. CONCLUSION: It was shown that gas density did not impact on convection dependent ventilation distribution in rats measured with EIT.  相似文献   

9.
Gravity-dependent changes of regional lung function were studied during normogravity, hypergravity, and microgravity induced by parabolic flights. Seven healthy subjects were followed in the right lateral and supine postures during tidal breathing, forced vital capacity, and slow expiratory vital capacity maneuvers. Regional 1) lung ventilation, 2) lung volumes, and 3) lung emptying behavior were studied in a transverse thoracic plane by functional electrical impedance tomography (EIT). The results showed gravity-dependent changes of regional lung ventilation parameters. A significant effect of gravity on regional functional residual capacity with a rapid lung volume redistribution during the gravity transition phases was established. The most homogeneous functional residual capacity distribution was found at microgravity. During vital capacity and forced vital capacity in the right lateral posture, the decrease in lung volume on expiration was larger in the right lung region at all gravity phases. During tidal breathing, the differences in ventilation magnitudes between the right and left lung regions were not significant in either posture or gravity phase. A significant nonlinearity of lung emptying was determined at normogravity and hypergravity. The pattern of lung emptying was homogeneous during microgravity.  相似文献   

10.
Excessive mechanical ventilation results in changes in lung tissue mechanics. We hypothesized that changes in tissue properties might be related to changes in the extracellular matrix component proteoglycans (PGs). The effect of different ventilation regimens on lung tissue mechanics and PGs was examined in an in vivo rat model. Animals were anesthetized, tracheostomized, and ventilated at a tidal volume of 8 (VT(8)), 20, or 30 (VT(30)) ml/kg, positive end-expiratory pressure of 0 (PEEP(0)) or 1.5 (PEEP(1.5)) cmH(2)O, and frequency of 1.5 Hz for 2 h. The constant-phase model was used to derive airway resistance, tissue elastance, and tissue damping. After physiological measurements, one lung was frozen for immunohistochemistry and the other was reserved for PG extraction and Western blotting. After 2 h of mechanical ventilation, tissue elastance and damping were significantly increased in rats ventilated at VT(30)PEEP(0) compared with control rats (ventilated at VT(8)PEEP(1.5)). Versican, basement membrane heparan sulfate PG, and biglycan were all increased in rat lungs ventilated at VT(30)PEEP(0) compared with control rats. At VT(30)PEEP(0), heparan sulfate PG and versican staining became prominent in the alveolar wall and airspace; biglycan was mostly localized in the airway wall. These data demonstrate that alterations in lung tissue mechanics with excessive mechanical ventilation are accompanied by changes in all classes of extracellular matrix PG.  相似文献   

11.
Tissue damage that is associated with the loss of cell membrane integrity should alter the bulk electrical properties of the tissue. This study shows that electrical impedance tomography (EIT) should be able to detect and image necrotic tissue inside the body due to the permeabilization of the membrane to ions. Cryosurgery, a minimally invasive surgical procedure that uses freezing to destroy undesirable tissue, was used to investigate the hypothesis. Experimental results with liver tissue demonstrate that cell damage during freezing results in substantial changes in tissue electrical properties. Two-dimensional EIT simulations of liver cryosurgery, which employ the experimental data, demonstrate the feasibility of this application.  相似文献   

12.

Background

Electrical Impedance measurements can be used to estimate the content of intra-thoracic air and thereby give information on pulmonary ventilation. Conventional Impedance measurements mainly indicate relative changes, but no information concerning air-volume is given. The study was performed to test whether a 3-point-calibration with known tidal volumes (VT) during conventional mechanical ventilation (CMV) allows subsequent calculation of VT from total Tidal-Impedance (tTI) measurements using Quadrant Impedance Measurement (QIM). In addition the distribution of TI in different regions of the thorax was examined.

Methodology and Principal Findings

QIM was performed in five neonatal piglets during volume-controlled CMV. tTI values at three different VT (4, 6, 8 ml/kg) were used to establish individual calibration curves. Subsequently, each animal was ventilated with different patterns of varying VT (2–10 ml/kg) at different PEEP levels (0, 3, 6, 9, 12 cmH2O). VT variation was repeated after surfactant depletion by bronchoalveolar lavage. VT was calculated from tTI values (VTcalc) and compared to the VT delivered by the ventilator (VTPNT). Bland-Altman analysis revealed good agreement between VTcalc and VTPNT before (bias −0.08 ml; limits of agreement −1.18 to 1.02 ml at PEEP = 3 cmH2O) and after surfactant depletion (bias −0.17 ml; limits of agreement −1.57 to 1.22 ml at PEEP = 3 cmH2O). At higher PEEP levels VTcalc was lower than VTPNT, when only one fixed calibration curve (at PEEP 3 cmH2O) was used. With a new calibration curve at each PEEP level the method showed similar accuracy at each PEEP level. TI showed a homogeneous distribution over the four assessed quadrants with a shift toward caudal regions of the thorax with increasing VT.

Conclusion

Tidal Impedance values could be used for precise and accurate calculation of VT during CMV in this animal study, when calibrated at each PEEP level.  相似文献   

13.
Regional changes in ventilation and perfusion occurring in the early hours after smoke inhalation injury were evaluated through the use of positron emission tomography. Five lambs were imaged before and 1, 2, and 4 h after receiving 100 breaths of cotton smoke. Utilizing a recently developed model of (13)N tracer kinetics (3), we evaluated changes in ventilation, perfusion, shunt, and regional gas content in nondependent, middle, and dependent lung zones. The data demonstrated a progressive development of regional shunt in dependent (dorsal) regions in which perfusion remained the highest throughout the study. These findings, together with decreasing regional ventilation and fractional gas content in the dependent regions, correlated with decreasing arterial Pa(O(2)) values over the course of the study. A negative correlation between regional shunt fraction and regional gas content in dependent and middle regions suggests that shunt was caused by progressive alveolar derecruitment or flooding.  相似文献   

14.
Effect of body orientation on regional lung expansion in dog and sloth   总被引:3,自引:0,他引:3  
Recent studies (E.A. Hoffman, J. Appl. Physiol. 59: 468-480, 1985) using fast multisliced X-ray computed tomography have demonstrated a ventral-dorsal gradient of fractional lung air content (3.29% air/cm lung height) in supine dogs and an essentially uniform ventral-dorsal air content distribution in the prone dogs [mean = 66 +/- 0.6% (SE) air content]. Since the prone orientation is the dog's normal body posture, we sought to study an animal whose normal body posture was "opposite" to that of the dog. Four two-toed sloths were scanned in the Dynamic Spatial Reconstructor in the prone and supine postures. A supine fractional air content gradient was demonstrated with a regression equation of y = 2.09x + 74.3 (r = 0.92), where y is percent air content and x is vertical height in the lung, and ventral-dorsal air content distribution in the prone posture was uniform with a mean of 85 +/- 0.4% (SE) air content. The low functional residual capacity lung density in the sloth was attributable to unusually large alveoli. The mean heart volume-to-body weight ratio in the dogs was 16.4 +/- 0.6 (SE) ml/kg and that in the sloth was 7.3 +/- 0.4 (SE) ml/kg. Mean lung volume-to-body weight ratios for dogs and sloths were 57 +/- 7 (SE) and 89 +/- 6 ml/kg, respectively. Of particular interest was the fact that large changes in prone vs. supine rib cage and diaphragm geometry previously found in dogs did not occur in sloths, though significant alterations of ventral and dorsal lung geometry prone vs. supine were demonstrated, and lung shape changes in both dog and sloth are attributable to shifts in the intrathoracic position of mediastinal structures.  相似文献   

15.

Introduction

Electrical impedance tomography (EIT) is an emerging clinical tool for monitoring ventilation distribution in mechanically ventilated patients, for which many image reconstruction algorithms have been suggested. We propose an experimental framework to assess such algorithms with respect to their ability to correctly represent well-defined physiological changes. We defined a set of clinically relevant ventilation conditions and induced them experimentally in 8 pigs by controlling three ventilator settings (tidal volume, positive end-expiratory pressure and the fraction of inspired oxygen). In this way, large and discrete shifts in global and regional lung air content were elicited.

Methods

We use the framework to compare twelve 2D EIT reconstruction algorithms, including backprojection (the original and still most frequently used algorithm), GREIT (a more recent consensus algorithm for lung imaging), truncated singular value decomposition (TSVD), several variants of the one-step Gauss-Newton approach and two iterative algorithms. We consider the effects of using a 3D finite element model, assuming non-uniform background conductivity, noise modeling, reconstructing for electrode movement, total variation (TV) reconstruction, robust error norms, smoothing priors, and using difference vs. normalized difference data.

Results and Conclusions

Our results indicate that, while variation in appearance of images reconstructed from the same data is not negligible, clinically relevant parameters do not vary considerably among the advanced algorithms. Among the analysed algorithms, several advanced algorithms perform well, while some others are significantly worse. Given its vintage and ad-hoc formulation backprojection works surprisingly well, supporting the validity of previous studies in lung EIT.  相似文献   

16.
Though well studied, acute respiratory distress syndrome (ARDS) is still not fully understood. Mechanical ventilation (MV) has been a key treatment for ARDS. However, the optimal ventilation settings of basic MV parameters are still significantly debated. Only recently, were low tidal volumes shown to have lower mortality rates among ARDS patients.Despite over two decades of study, no standardisation of therapy or approach to MV appears on the horizon. This problem is likely due to the heterogeneity of the ARDS patient and ARDS affected lung. Currently, external MV parameters are set to try and treat an internal condition. There is no way to determine if more harm than good is being done. Hence, there is a tradeoff in between the risk of and benefit. What is required a method to assess that tradeoff and thus the potential risk.The use of positive end expiratory pressure (PEEP) and tidal volume has been identified as key ventilation parameters when treating ARDS patients. Although the impact of both parameters has been studied extensively, only the use of low tidal volumes has been conclusively determined. In contrast, the application of PEEP is still widely disputed.This review discusses two different approaches to ventilation management and the impact on optimal PEEP. The first approach examines the use of imaging techniques to determine regional lung mechanics. In the past, computed tomography (CT) was seen as a way to optimise PEEP, but the risks associated with it have limited it to a research tool. Newer methods such as lung ultrasound and electrical impedance tomography (EIT) seem to offer a less riskier approach to assessing regional mechanics.The second approach examines model-based approaches to ventilation management. Models that take ventilation data and depict a physical picture offer the potential to assess the risks on a patient-specific basis. Models offer the benefit of creating an approach to a highly heterogeneously and patient-specific problem in a non-invasive manner. Given the added dynamic of a patient's evolution over time, a highly patient-specific approach is typical and also what is required. Although both approaches can potentially be used to help with clinical decision making with regard to PEEP, they both pose advantages and disadvantages. The use of a given approach will depend on the individual needs of each clinic. Although not currently deployed in the clinic, model-based methods represent a novel methodology in treating ARDS patients. Thus, model-based approaches represent a “state of possible” rather than currently practiced methods, and require further clinical validation before justifying their use in the clinic.  相似文献   

17.
The effects of changing tidal volume (VT) and frequency (f) on the distribution of ventilation during high-frequency ventilation (HFV) were assessed from the washout of nitrogen-13 by positron emission tomography. Six dogs, anesthetized and paralyzed, were studied in the supine position during conventional ventilation (CV) and during HFV at f of 3, 6, and 9 Hz. In CV and HFV at 6 Hz, VT was selected to achieve eucapnic arterial partial pressure of CO2 (37 +/- 3 Torr). At 3 and 9 Hz, VT was proportionally changed so that the product of VT and f remained constant and equal to that at 6 Hz. Mean residence time (MRT) of nitrogen-13 during washout was calculated for apical, midheart, and basal transverse sections of the lung and further analyzed for gravity-dependent, cephalocaudal and radial gradients. An index of local alveolar ventilation per unit of lung volume, or specific ventilation (spV), was calculated as the reciprocal of MRT. During CV vertical gradients of regional spV were seen in all sections with ventral (nondependent) regions less ventilated than dorsal (dependent) regions. Regional nonuniformity in gas transport was greatest for HFV at 3 and 6 Hz and lowest at 9 Hz and during CV. During HFV, a central region at the base of the lungs was preferentially ventilated, resulting in a regional time-averaged tracer concentration equivalent to that of the main bronchi. Because the main bronchi were certainly receiving fresh gas, the presence of this preferentially ventilated area, whose ventilation increased with VT, strongly supports the hypothesis that direct convection of fresh gas is an important mechanism of gas transport during eucapnic HFV. Aside from the local effect of increasing overall lung ventilation, this central area probably served as an intermediate shuttle station for the transport of gas between mouth and deeper alveoli when VT was less than the anatomic dead space.  相似文献   

18.
Retinal explants of mouse embryos were cultured together with explants of different regions in the retinofugal pathway in order to investigate whether ventral temporal (VT) and dorsal nasal (DN) retinal neurites showed differential responses to regional-specific cues in the pathway. In the presence of the chiasm, biased outgrowth of retinal neurites was found in explants of both retinal regions, which was accompanied by a reduction in total neurite growth in the VT but not the DN retina. Such differential responses to the diffusible negative influence were also observed when explants of two retinal origins were cocultured with the ventral diencephalon, but were not found with the dorsal diencephalon that contains targets of the optic axons. Indeed, extensive neurite invasion was found in the dorsal diencephalic explants and this ingrowth was more prominent for VT than DN neurites, showing a difference in axons from a distinct position in the retina to contact-mediated stimulatory activity within the target nuclei. We conclude that neurites from different regions of the retina show differential responses to the regional-specific cues in the diencephalon. These cues exist in both diffusible and contact-mediated forms that may shape the characteristic course and organization of retinal axons in decision regions of the optic pathway and the visual targets.  相似文献   

19.
20.

Objective

Variations of conductive fluid content in brain tissue (e.g. cerebral edema) change tissue impedance and can potentially be measured by Electrical Impedance Tomography (EIT), an emerging medical imaging technique. The objective of this work is to establish the feasibility of using EIT as an imaging tool for monitoring brain fluid content.

Design

a prospective study.

Setting

In this study EIT was used, for the first time, to monitor variations in cerebral fluid content in a clinical model with patients undergoing clinical dehydration treatment. The EIT system was developed in house and its imaging sensitivity and spatial resolution were evaluated on a saline-filled tank.

Patients

23 patients with brain edema.

Interventions

The patients were continuously imaged by EIT for two hours after initiation of dehydration treatment using 0.5 g/kg intravenous infusion of mannitol for 20 minutes.

Measurement and Main Results

Overall impedance across the brain increased significantly before and after mannitol dehydration treatment (p = 0.0027). Of the all 23 patients, 14 showed high-level impedance increase and maintained this around 4 hours after the dehydration treatment whereas the other 9 also showed great impedance gain during the treatment but it gradually decreased after the treatment. Further analysis of the regions of interest in the EIT images revealed that diseased regions, identified on corresponding CT images, showed significantly less impedance changes than normal regions during the monitoring period, indicating variations in different patients'' responses to such treatment.

Conclusions

EIT shows potential promise as an imaging tool for real-time and non-invasive monitoring of brain edema patients.  相似文献   