首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The objective of this study was to predict time-dependent bone remodeling around tissue- and bone-level dental implants used in patients with reduced bone width. The remodeling of bone around titanium tissue-level, and titanium and titanium–zirconium alloy bone-level implants was studied under 100 N oblique load for one month by implementing the Stanford theory into three-dimensional finite element models. Maximum principal stress, minimum principal stress, and strain energy density in peri-implant bone and displacement in x- and y- axes of the implant were evaluated. Maximum and minimum principal stresses around tissue-level implant were higher than bone-level implants and both bone-level implants experienced comparable stresses. Total strain energy density in bone around titanium implants slightly decreased during the first two weeks of loading followed by a recovery, and the titanium–zirconium implant showed minor changes in the axial plane. Total strain energy density changes in the loading and contralateral sides were higher in tissue-level implant than other implants in the cortical bone at the horizontal plane. The displacement values of the implants were almost constant over time. Tissue-level implants were associated with higher stresses than bone-level implants. The time-dependent biomechanical outcome of titanium–zirconium alloy bone-level implant was comparable to the titanium implant.  相似文献   

2.
Microbiologically influenced corrosion: looking to the future.   总被引:5,自引:0,他引:5  
This review discusses the state-of-the-art of research into biocorrosion and the biofouling of metals and alloys of industrial usage. The key concepts needed to understand the main effects of microorganisms on metal decay, and current trends in monitoring and control strategies to mitigate the deleterious effects of biocorrosion and biofouling are also described. Several relevant cases of biocorrosion studied by our research group are provided as examples: (i) biocorrosion of aluminum and its alloys by fungal contaminants of jet fuels; (ii) sulfate-reducing bacteria (SRB)-induced corrosion of steel; (iii) biocorrosion and biofouling interactions in the marine environment; (iv) monitoring strategies for assessing biocorrosion in industrial water systems; (v) microbial inhibition of corrosion; (vi) use and limitations of electrochemical techniques for evaluating biocorrosion effects. Future prospects in the field are described with respect to the potential of innovative techniques in microscopy (environmental scanning electron microscopy, confocal scanning laser microscopy, atomic force microscopy), new spectroscopic techniques for the study of corrosion products and biofilms (energy dispersion X-ray analysis, X-ray photoelectron spectroscopy, electron microprobe analysis) and electrochemistry (electrochemical impedance spectroscopy, electrochemical noise analysis).  相似文献   

3.
Orthopaedic metal implants composed of titanium are routinely used in bone fracture repair and for joint replacement therapies. A considerable fraction of implant recipients are unable to benefit due to implant failure resulting from aseptic loosening, while others may experience cutaneous sensitivity to titanium after implantation. An adaptive immune reactivity towards titanium ions, originating from the biocorrosion of the implants, could play a role. As an initiator of the adaptive immune response, dendritic cells (DC) were studied for uptake and characteristics after titanium exposure. Energy filtered transmission electron microscopy showed uptake of titanium(iv) (Ti(iv)) ions by DCs in vitro and co-localisation with phosphorus-rich cell structures of the DC membranes (phospholipids), cytoplasm (ribosomes and phosphorylated proteins) and the nucleus (DNA). DC maturation and function were investigated by measuring cell surface marker expression by flow cytometry. After exposure, DCs showed a decrease in MHC class II (HLA-DR), co-stimulatory molecules (CD40, CD80 & CD86) and chemokine receptors (CCR) 6 and CCR7 but an increase in CCR4 after Ti(iv) treatment. However, Ti(iv) treated DCs had an increased stimulatory capacity towards allogenic lymphocytes. A Ti(iv) concentration dependant increase of IL-12p70 was observed amidst decrease of the other measured cytokines (TGF-β1 and TGF-β2). Hence, Ti(iv) alters DC properties, resulting in an enhanced T lymphocyte reactivity and deviation towards a Th1 type immune response. This effect may be responsible for the inflammatory side effects of titanium implants seen in patients.  相似文献   

4.
The objective of the present study is to evaluate bone loss at implant abutments coated with a soda-lime glass containing silver nanoparticles subjected to experimental peri-implantitis. Five beagle dogs were used in the experiments, 3 implants were installed in each quadrant of the mandibles. Glass/n-Ag coted abutments were connected to implant platform. Cotton floss ligatures were placed in a submarginal position around the abutment necks and the animals were subject to a diet which allowed plaque accumulation, and after 15 weeks the dogs were sacrificed. Radiographs of all implant sites were obtained at the beginning and at the end of the experimentally induced peri-implantitis. The radiographic examination indicated that significant amounts of additional bone loss occurred in implants without biocide coating, considering both absolute and relative values of bone loss. Percentages of additional bone loss observed in implants dressed with a biocide coated abutment were about 3 times lower (p<0.006 distal aspect; and p<0.031 at mesial aspect) than the control ones. Within the limits of the present study it seems promising the use of soda-lime glass/nAg coatings on abutments to prevent peri-implant diseases.  相似文献   

5.
The presence of microorganisms on material surfaces can have a profound effect on materials performance. Surface-associated microbial growth, i.e. a biofilm, is known to instigate biofouling. The presence of biofilms may promote interfacial physico-chemical reactions that are not favored under abiotic conditions. In the case of metallic materials, undesirable changes in material properties due to a biofilm (or a biofouling layer) are referred to as biocorrosion or microbially influenced corrosion (MIC). Biofouling and biocorrosion occur in aquatic and terrestrial habitats varying in nutrient content, temperature, pressure and pH. Interfacial chemistry in such systems reflects a wide variety of physiological activities carried out by diverse microbial populations thriving within biofilms. Biocorrosion can be viewed as a consequence of coupled biological and abiotic electron-transfer reactions, i.e. redox reactions of metals, enabled by microbial ecology. Microbially produced extracellular polymeric substances (EPS), which comprise different macromolecules, mediate initial cell adhesion to the material surface and constitute a biofilm matrix. Despite their unquestionable importance in biofilm development, the extent to which EPS contribute to biocorrosion is not well-understood. This review offers a current perspective on material/microbe interactions pertinent to biocorrosion and biofouling, with EPS as a focal point, while emphasizing the role atomic force spectroscopy and mass spectrometry techniques can play in elucidating such interactions.  相似文献   

6.
The aim of the present study was to evaluate bone loss at implants connected to abutments coated with a soda-lime glass containing silver nanoparticles, subjected to experimental peri-implantitis. Also the aging and erosion of the coating in mouth was studied. Five beagle dogs were used in the experiments. Three implants were placed in each mandible quadrant: in 2 of them, Glass/n-Ag coated abutments were connected to implant platform, 1 was covered with a Ti-mechanized abutment. Experimental peri-implantitis was induced in all implants after the submarginal placement of cotton ligatures, and three months after animals were euthanatized. Thickness and morphology of coating was studied in abutment cross-sections by SEM. Histology and histo-morphometric studies were carried on in undecalfied ground slides. After the induced peri-implantitis: 1.The abutment coating shown losing of thickness and cracking. 2. The histometry showed a significant less bone loss in the implants with glass/n-Ag coated abutments. A more symmetric cone of bone resorption was observed in the coated group. There were no significant differences in the peri-implantitis histological characteristics between both groups of implants. Within the limits of this in-vivo study, it could be affirmed that abutments coated with biocide soda-lime-glass-silver nanoparticles can reduce bone loss in experimental peri-implantitis. This achievement makes this coating a suggestive material to control peri-implantitis development and progression.  相似文献   

7.
Role of iron-reducing bacteria in corrosion and protection of carbon steel   总被引:2,自引:0,他引:2  
The role of iron-reducing bacteria (IRB) in biocorrosion is under discussion. According to some reports, IRB are able to induce protection of carbon steel while others suggest an important enhancement of corrosion through the reduction and removal of passive films of ferric compounds on the metal surface. In this work, we review recent knowledge concerning microbial respiration, the ecology of IRB containing biofilms and the corrosive or protective effect of such biofilms on metal surfaces.  相似文献   

8.
ObjectivesThe aim of the present study is to evaluate, in a ligature-induced peri-implantitis model, the efficacy of three antimicrobial glassy coatings in the prevention of biofilm formation, intrasulcular bacterial growth and the resulting peri-implant bone loss.MethodsMandibular premolars were bilaterally extracted from five beagle dogs. Four dental implants were inserted on each hemiarch. Eight weeks after, one control zirconia abutment and three with different bactericidal coatings (G1n-Ag, ZnO35, G3) were connected. After a plaque control period, bacterial accumulation was allowed and biofilm formation on abutments was observed by Scanning Electron Microscopy (SEM). Peri-implantitis was induced by cotton ligatures. Microbial samples and peri-implant crestal bone levels of all implant sites were obtained before, during and after the breakdown period.ResultsDuring experimental induce peri-implantitis: colony forming units counts from intrasulcular microbial samples at implants with G1n-Ag coated abutment remained close to the basal inoculum; G3 and ZnO35 coatings showed similar low counts; and anaerobic bacterias counts at control abutments exhibited a logarithmic increase by more than 2. Bone loss during passive breakdown period was no statistically significant. Additional bone loss occurred during ligature-induce breakdown: 0.71 (SD 0.48) at G3 coating, 0.57 (SD 0.36) at ZnO35 coating, 0.74 (SD 0.47) at G1n-Ag coating, and 1.29 (SD 0.45) at control abutments; and statistically significant differences (p<0.001) were found. The lowest bone loss at the end of the experiment was exhibited by implants dressing G3 coated abutments (mean 2.1; SD 0.42).SignificanceAntimicrobial glassy coatings could be a useful tool to ward off, diminish or delay peri-implantitis progression.  相似文献   

9.
王倩  胡欢  范芹  马锐  彭泽惠  刘建国 《微生物学通报》2019,46(11):3084-3090
种植体周围炎是发生在骨性结合种植体周围组织的炎症,是由微生物引发的感染性疾病,可引起种植体周围支持组织丧失而导致种植失败。阐明种植体周围炎生物膜的微生物学基础,可为制定相应防治策略提供理论依据。随着测序技术的发展,基于16S rRNA基因的测序分析技术逐渐应用于与口腔种植体相关的微生物学研究,使人们对种植体周围炎生物膜的微生物群落多样性有了更全面的了解,也进一步认识到种植体周围炎和牙周炎菌斑生物膜的微生物结构存在显著差别。本文根据基于16S rRN基因A序列分析技术的最新研究成果,对种植体周围炎菌斑生物膜的微生物学研究进展作一综述。  相似文献   

10.
Peri-implantitis is an infectious disease, which leads to loss of supporting bone around dental implants. To evaluate the extent and location of bone loss, 43 patients with peri-implantitis were examined. The bone loss was clinically measured at the time of dental surgery. Data revealed that 25% of subjects had bone loss associated with all their implants although the majority of the subjects had fewer than 50% of their implants affected by bone loss. A total number of 264 implants were examined and 131 of those had peri-implantitis associated bone loss. The pattern of bone loss at implants varied between and within subjects and location in the jaws. The highest proportion of implants with peri-implantitis was found in the upper jaw and within this group, at implants located in the incisor area of the upper jaw; the lowest was the canine area of the lower jaw. The highest proportion of implants that lost ≥ 2/3 of their bone support was found in the incisor area of the maxilla. We concluded that in the presence of peri-implant inflammation, bone quantity and characteristics may influence the progression of peri-implantitis bone loss at dental implants. We hypothesize that the ability of the bone to withstand occlusal forces will be altered as consequence of the loss of bone at the neck of the implants. To achieve an understanding of the local degradation of bone due to peri-implantitis, we need to analyze the microstructure of the bone as well the cellular biology of the peri-implant inflammation.  相似文献   

11.
Microbial colonization of metals and alloys of industrial usage takes place through the formation of biofilms made of bacteria, extracellular polymeric substances (EPS) and mainly water. These biological deposits can drastically modify the corrosion behavior of structural metals and alloys enhancing localized alterations in the type and concentrations of ions, pH, and oxygen levels. However, biofilms also facilitate the formation of diffusional barriers to the exchange of chemical species from and towards the metal/solution interface. Problems due to biocorrosion and biofouling of industrial systems range from heavy microbiological contamination with consequent energy and efficiency losses to structural failures owing to corrosion.The use of appropriate monitoring strategies complemented with field and laboratory microbiological techniques is necessary to reach a proper understanding of the effects derived from microbiological activity and the role of biofilms in the corrosion reaction to later implement effective control and preventive countermeasures. It must be emphasized that this assessment should be made for each industrial system, considering its previous history, present operational conditions, physicochemical composition of the intake water and the number and identity of microbial contaminants.Cleaning procedures, most relevant biocides and other methods for prevention and control of biocorrosion like coatings, and cathodic protection are successively described. Updated information about monitoring strategies is also included in the final part of the paper.  相似文献   

12.
Controlling the formation and reconstruction of microbial biofilms is of ever increasing importance for the ecological, medical, and biotechnological aspects of biofilm studies. The goal of this review was to provide systematization and analysis of the results obtained in recent years on the modes and mechanisms of the stimulatory or inhibitory effect of extreme factors and biocidal agents on biofilm formation. Special attention is paid to controlling the formation of medically (infective diseases, implant biofouling) and technologically or biotechnologically important biofilms (bioremediation, biocorrosion, and biosynthesis of biologically active compounds).  相似文献   

13.
Abstract

There is a current trend to propose cementless total joint arthroplasty (TJA) to younger patients. These patients have more demanding physical activity resulting in an increased failure rate of the implants. In particular for these type of patients, the desired service life of the implant should be extended. The actual implant used do not fulfil this requirement.

In this study, a new concept of orthopaedic implant is presented where the implant is not only a structural support but also a local drug delivery system. The delivered drug is meant to influence the bone remodeling in a way so as to compensate the effects of peri-implant osteolysis. To test this concept, we extended an existing bone remodeling model to include the effect of a drug. The results show that a more homogeneous bone density distribution can be obtained around the implant. Implants used as drug delivery systems could then be an alternative way to increase implant service life.  相似文献   

14.
The study focused on the influence of the implant material stiffness on stress distribution and micromotion at the interface of bone defect implants. We hypothesized that a low-stiffness implant with a modulus closer to that of the surrounding trabecular bone would yield a more homogeneous stress distribution and less micromotion at the interface with the bony bed. To prove this hypothesis we generated a three-dimensional, non-linear, anisotropic finite element (FE) model. The FE model corresponded to a previously developed animal model in sheep. A prismatic implant filled a standardized defect in the load-bearing area of the trabecular bone beneath the tibial plateau. The interface was described by face-to-face contact elements, which allow press fits, friction, sliding, and gapping. We assumed a physiological load condition and calculated contact pressures, shear stresses, and shear movements at the interface for two implants of different stiffness (titanium: E=110GPa; composite: E=2.2GPa). The FE model showed that the stress distribution was more homogeneous for the low-stiffness implant. The maximum pressure for the composite implant (2.1 MPa) was lower than for the titanium implant (5.6 MPa). Contrary to our hypothesis, we found more micromotion for the composite (up to 6 microm) than for the titanium implant (up to 4.5 microm). However, for both implants peak stresses and micromotion were in a range that predicts adequate conditions for the osseointegration. This was confirmed by the histological results from the animal studies.  相似文献   

15.
The surface state of titanium implants modulates bone response and implant anchorage. This evidence brought implant manufacturers to switch from the standard surface refinements and implement new surface treatments for more bone apposition and enhanced interfacial strength measured by removal torque or push-out tests. Anodic plasma-chemical treatment of implant surfaces is a cost-effective process to modify surface topography and chemistry. This technique is used for structuring connected with a coating of implant surfaces. The aim of our investigations, here, is to texture the implant surface in the nanoscale without coating. Ti disks with different mechanical pre-treatment (grinded, glass blasted) were used as substrate. Micro-plasma texturing was carried out in an aqueous electrolyte. By applying a pulsed DC voltage to the specimen, micro-plasma discharge was generated in the thin steam film between immersed specimen and electrolyte. The electrical process parameter current density was varied. The micro-plasma textured Ti surfaces were characterised optically by SEM and electrochemically by CV- (for testing the corrosion parameters), CA- (to give the enlargement of the real surface) and EIS-measurement in range of 100 kHz-100 microHz. We found that the initial structure of the material surface has small or no influence on the results of the micro-plasma treatment. The properties of the thick oxide layer resulting from the plasma process are influenced by electrical process parameters. After removal of the thick oxide layer a fine, micro- and nanoscaled surface structure of the titanium remains.  相似文献   

16.
Currently used orthopedic implants composed of titanium have a limited functional lifetime of only 10–15 years. One of the reasons for this persistent problem is the poor prolonged ability of titanium to remain bonded to juxtaposed bone. It has been proposed to modify titanium through anodization to create a novel nanotubular topography in order to improve cytocompatibility properties necessary for the prolonged attachment of orthopedic implants to surrounding bone. Additionally, electrical stimulation has been used in orthopedics to heal bone non-unions and fractures in anatomically difficult to operate sites (such as the spine). In this study, these two approaches were combined as the efficacy of electrical stimulation to promote osteoblast (bone forming cell) density on anodized titanium was investigated. To do this, osteoblast proliferation experiments lasting up to 5 days were conducted as cells were stimulated with constant bipolar pulses at a frequency of 20 Hz and a pulse duration of 0.4 ms each day for 1 hour. The stimulation voltages were 1 V, 5 V, 10 V, and 15 V. Results showed for the first time that under electrical stimulation, osteoblast proliferation on anodized titanium was enhanced at lower voltages compared to what was observed on conventional (nonanodized) titanium. In addition, compared to nonstimulated conventional titanium, osteoblast proliferation was enhanced 72% after 5 days of culture on anodized nanotubular titanium at 15 V of electrical stimulation. Thus, results of this study suggest that coupling the positive influences of electrical stimulation and nanotubular features on anodized titanium may improve osteoblast responses necessary for enhanced orthopedic implant efficacy.  相似文献   

17.
Biocorrosion is a common problem in oil and gas industry facilities. Characterization of the microbial populations responsible for biocorrosion and the interactions between different microorganisms with metallic surfaces is required in order to implement efficient monitoring and control strategies. Denaturing gradient gel electrophoresis (DGGE) analysis was used to separate PCR products and sequence analysis revealed the bacterial composition of a consortium obtained from a sour gas pipeline in the Gulf of Mexico. Only one species of sulfate-reducing bacteria (SRB) was detected in this consortium. The rest of the population consisted of enteric bacteria with different characteristics and metabolic capabilities potentially related to biocorrosion. Therefore, several types of bacteria may be involved in biocorrosion arising from natural biofilms that develop in industrial facilities. The low abundance of the detected SRB was evidenced by environmental scanning electron microscopy (ESEM). In addition, the localized corrosion of pipeline steel in the presence of the consortium was clearly observed by ESEM after removing the adhered bacteria.  相似文献   

18.
This cross-sectional study aimed to identify and quantify up to 42 target species colonizing the early biofilm of dental implants restored with titanium or zirconia abutments. A total of 720 samples from 20 healthy individuals were investigated. Biofilm samples were collected from the peri-implant sulci, inner parts of implants, abutment surfaces and prosthetic crowns over a functioning period of 30 days. Checkerboard DNA–DNA hybridization was used for microbial detection and quantitation. Clinical characteristics (probing depth, bleeding on probing, clinical attachment level and marginal bone loss) were also investigated during the monitoring period. Genome counts were low at the implant loading time point for both the abutment materials, and increased over time. Both the titanium and the zirconia groups presented similar microbial counts and diversity over time, and the microbiota was very similar to that colonizing the remaining teeth. Clinical findings were consistent with a healthy condition with no significant difference regarding marginal bone loss between the two materials.  相似文献   

19.
《IRBM》2007,28(1):42-48
Dental implant-associated infections as peri-implantitis represent one of the major causes of osteointegration failures of oral implants. Adhesion of Porphyromonas gingivalis, one of the bacterial strains mainly involved in such infections, is tightly dependent on the topographical and/or physico-chemical properties of the implant surfaces. As a matter of fact, we showed that the grafting of one bioactive polymer such as poly(sodium styrene sulfonate) onto titanium implant surfaces allowed a sensitive decrease of Staphylococcus aureus adhesion (> 40%). The aim of the study consists in evaluating the adhesion of P. gingivalis onto titanium surfaces grafted with poly(sodium stryrene sulfonate) in order to elaborate implants exhibiting appropriate inhibiting properties towards the adhesion of periodontal pathogens. The grafting of poly(sodium stryrene sulfonate) onto titanium surfaces is carried out in two steps: chemical oxydation of titanium to initiate radical species then grafting of poly(sodium stryrene sulfonate) by radical polymerization. Chemical characterization of the surfaces is achieved by Fourier transformed infrared spectroscopy (FTIR). Bacterial adhesion was studied on grafted and non grafted (control) titanium surfaces, preadsorbed or not by plasmatic proteins. Protein adsorption as well as bacteria adhesion is followed by fluorescence spectroscopy by using proteins or bacteria previously labelled with fluorescence probes; the quantification of adsorption and bacteria adhesion are performed by image analysis. Results showed that protein adsorption is more important (~3 times) and that P. gingivalis adhesion is strongly inhibited (~73%) onto poly(sodium styrene sulfonate) grafted surfaces when compared to titanium control. Moreover, the inhibition of bacterial adhesion on grafted surfaces preadsorbed with plasma proteins is comparable to that observed on grafted surfaces preadsorbed with fibronectin. In conclusion, the obtained results evidenced that the grafting of titanium surface by poly(sodium styrene sulfonate) led to significant inhibition of P. gingivalis adhesion and that this inhibitory activity involved adsorbed proteins. Poly(sodium styrene sulfonate) grafted titanium surfaces present a high interest for the elaboration of oral implants in various clinical dental applications.  相似文献   

20.
The oil-water-gas environments of oil production facilities harbour abundant and diverse microbial communities that can participate in deleterious processes such as biocorrosion. Several molecular methods, including pyrosequencing of 16S rRNA libraries, were used to characterize the microbial communities from an oil production facility on the Alaskan North Slope. The communities in produced water and a sample from a 'pig envelope' were compared in order to identify specific populations or communities associated with biocorrosion. The 'pigs' are used for physical mitigation of pipeline corrosion and fouling and the samples are enriched in surface-associated solids (i.e. paraffins, minerals and biofilm) and coincidentally, microorganisms (over 10(5) -fold). Throughout the oil production facility, bacteria were more abundant (10- to 150-fold) than archaea, with thermophilic members of the phyla Firmicutes (Thermoanaerobacter and Thermacetogenium) and Synergistes (Thermovirga) dominating the community. However, the structure (relative abundances of taxa) of the microbial community in the pig envelope was distinct due to the increased relative abundances of the genera Thermacetogenium and Thermovirga. The data presented here suggest that bulk fluid is representative of the biofilm communities associated with biocorrosion but that certain populations are more abundant in biofilms, which should be the focus of monitoring and mitigation strategies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏