首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Sodium tanshinone IIA sulfonate (STS), a hydrophilic ionic substance, is used as a cardiovascular drug. An ion-pair reversed-phase high-performance liquid chromatography (IP-RP-HPLC) method for the determination of STS in mouse plasma was initially developed. The assay involved a rapid and simple extraction process and subsequent detection at 271 nm. The retention time for STS was 7.5 min. Based on extracted STS standard mouse plasma at 1.5,10 and 50 microg/ml, the assay precision were 2.7, 2.1 and 1.7% with a mean accuracy of 96.7, 98.5 and 99.4%, respectively. At plasma concentration of 1.5, 50 and 75 microg/ml, the mean recovery of STS were 93.1, 96.3 and 97.5%. The limit of detection (LOD) and limit of quantification (LOQ) for STS was 0.1 microg/ml and 0.5 microg/ml, respectively. Linear responses were observed over a wide concentration range (0.5-100 microg/ml) for STS in mouse plasma. STS can be detected after intravenous administration. This method was performed for the first time in pharmacokinetic studies of STS in the mouse.  相似文献   

2.
A rapid, sensitive and accurate high-performance liquid chromatographic method with UV detection was developed and validated for the quantification of gabapentin in human plasma. Gabapentin was quantified using pre-column derivatization with 1-fluoro-2,4-dinitrobenzene following protein precipitation of plasma with acetonitrile. Amlodipine was used as internal standard. The chromatographic separation was carried out on a Nova-Pak C(18) column using a mixture of 50 mM NaH(2)PO(4) (pH=2.5)-acetonitrile (30:70, v/v) as mobile phase with UV detection at 360 nm. The flow rate was set at 1.5 ml/min. The method was linear over the range of 0.05-5 microg/ml of gabapentin in plasma (r(2)>0.999). The within-day and between-day precision values were in the range of 2-5%. The limit of quantification of the method was 0.05 microg/ml. The method was successfully used to study the pharmacokinetics of gabapentin in healthy volunteers.  相似文献   

3.
The development and validation of a high-performance liquid chromatographic and UV detection method was accomplished for quantitative determination of levamisole in chicken tissues, eggs and plasma. The chromatographic separation was achieved on Luna 5 microm C(18) column using a mobile phase of 0.2% acetic acid in water:methanol (50:50 (v/v)) and Pic B-7 low UV reagent and the pH was adjusted to 7.31 with ammonium hydroxide and UV wavelength was 225 nm. Limits of quantification were 0.025 microg/g for all tissues and 0.003 microg/ml for plasma. Limit of detection was 0.001 microg/g for tissues and plasma.  相似文献   

4.
A stereoselective reversed-phase HPLC assay to determine S-(-) and R-(+) enantiomers of esmolol in human plasma was developed. The method involved liquid-liquid extraction of esmolol from human plasma, using S-(-)-propranolol as the internal standard, and employed 2,3,4,6-tetra-O-acetyl-beta-d-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The derivatized products were separated on a 5-microm reversed-phase C18 column with a mixture of acetonitrile/0.02 mol/L phosphate buffer (pH 4.5) (55:45, v/v) as mobile phase. The detection of esmolol derivatives was made at lambda=224 nm with UV detector. The assay was linear from 0.035 to 12 microg/ml for each enantiomer. The analytical method afforded average recoveries of 94.8% and 95.5% for S-(-)- and R-(+)-esmolol, respectively. For each enantiomer, the limit of detection was 0.003 microg/ml and the limit of quantification for the method was 0.035 microg/ml (RSD<14%). The reproducibility of the assay was satisfactory.  相似文献   

5.
A rapid method was developed for quantification of nimesulide (methanesulfonamide, N-[4-nitro-2-phenoxyphenil]) in rabbit aqueous humor. The analyses were performed by high-performance liquid chromatography using a C(18) reversed-phase column (Ultracarb ODS) with UV detection at 300 nm. The mobile phase consisted of acetonitrile-water containing 1% triethylamine (TEA) adjusted to pH 3.2 with orthophosphoric acid. The retention time was 4.5 min. A simple pre-treatment with acetonitrile was used to deproteinize aqueous humor samples. The limit of quantitation was 50 ng/ml. The recovery was over 90%. The relationship between peak areas and concentration was linear over the range between 0.05 and 2.5 microg/ml, with r(2) values over 0.99. The assay provided good reproducibility and accuracy and proved to be suitable for pharmacokinetic studies of nimesulide.  相似文献   

6.
A reversed-phase high-performance liquid chromatographic method using a mobile phase of acetonitrile-methanol-trifluoroacetic acid-water (16.1:7.2:0.1:76.6, v/v/v/v) at a flow rate of 1.0 ml min(-1) on a LiChrospher RP-18 column with UV (254 nm) detection has been developed for the separation of sulfadoxine and its metabolite N-acetyl sulfadoxine in plasma. No interferences due to endogenous compounds or common antimalarial drugs were noticed. The limit of detection for sulfadoxine and N-acetyl sulfadoxine was 0.01 microg ml(-1) with a signal-to-noise ratio of 5:1 while the limit of quantification was 2.5 microg ml(-1). Intra-day mean relative standard deviations (RSD's) for sulfadoxine and N-acetyl sulfadoxine were 2.6 and 2.8%, respectively, while mean inter-day RSD's for sulfadoxine and N-acetyl sulfadoxine were 2.4 and 2.8%, respectively. Extraction recoveries averaged 90.6% for sulfadoxine and 86.9% for N-acetyl sulfadoxine. The method was applied for the assay of sulfadoxine and its metabolite N-acetyl sulfadoxine in plasma from Plasmodium falciparum malaria patients. Mean plasma sulfadoxine concentrations on day 2 (51 h) from samples collected from sensitive and resistant P. falciparum patients treated with three tablets of Fansidar were 62.8 and 60.5 microg ml(-1), respectively. Mean ratio of N-acetyl sulfadoxine to sulfadoxine was 9.1% for responders and 13.9% for non-responders which revealed that higher amounts of the metabolite N-acetyl sulfadoxine were present in non-responders. The method described should find an application in the therapeutic monitoring of malaria patients.  相似文献   

7.
A simple method for the measurement of the active leflunomide metabolite A77 1726 in human plasma by HPLC is presented. The sample workup was simple, using acetonitrile for protein precipitation. Chromatographic separation of A77 1726 and the internal standard, alpha-phenylcinnamic acid, was achieved using a C(18) column with UV detection at 305 nm. The assay displayed reproducible linearity for A77 1726 with determination coefficients (r2) > 0.997 over the concentration range 0.5-60.0 microg/ml. The reproducibility (%CV) for intra- and inter-day assays of spiked controls was <5%. The limit of quantification was 0.8 microg/ml. The average absolute recovery was approximately 100%. This assay is suitable for the determination of A77 1726 in plasma of patients taking leflunomide, and is simpler to use than other HPLC methods reported previously.  相似文献   

8.
A method based on cloud-point extraction (CPE) was developed for the determination of flurbiprofen (FP) in rat plasma after oral and transdermal administration by high-performance liquid chromatography coupled with UV detection (HPLC-UV). The non-ionic surfactant Genapol X-080 was chosen as the extract solvent. Variables parameter affecting the CPE efficiency were evaluated and optimized. Chromatography separation was performed on a Diamond C(18) column (4.6 mm i.d. x 250 mm, 10 microm particle size) by isocratic elution with UV detection at 254 nm. The assay was linear over the range of 0.2-50 and 0.1-10 microg/ml for oral and transdermal administration, respectively, and the lower limit of quantification (LLOQ) was 0.1 microg/ml. The extraction recoveries were more than 84.5%, the accuracies were within +/-3.8%, and the intra- and inter-day precisions were less than 10.1% in all cases. After strict validation, the method indicated good performance in terms of reproducibility, specificity, linearity, precision and accuracy, and it was successfully applied to the pharmacokinetic study of flurbiprofen in rats after oral and transdermal administration.  相似文献   

9.
A rapid, sensitive and simple high-performance liquid chromatographic (HPLC) method with ultraviolet detector (UV) has been developed for the determination of bifendate in 100 microl plasma of rats. Sample preparation was carried out by deproteinization with 100 microl of acetonitrile. A 20 microl of supernatant was directly injected into the HPLC system with methanol-double distilled water (65/35, v/v) as the mobile phase at a flow rate of 1.0 ml/min. Separation was performed with a microBondapak C(18) column at 30 degrees C. The peak was detected at 278 nm. The calibration curve was linear (r(2)=0.9989) in the concentration range of 0.028-2.80 microg/ml in plasma. The intra- and inter-day variation coefficients were not more than 6.55% and 6.07%, respectively. The limit of detection was 5 ng/ml. The mean recoveries of bifendate were ranged from 94.53% to 99.36% in plasma. The present method has been successfully applied to the pharmacokinetic study of bifendate liposome in rats.  相似文献   

10.
A simple and reliable HPLC method was developed for the estimation of a new anti-cancer agent that belongs to the thioxanthone class, SR271425 in mouse plasma. SR271425, it’s metabolites and internal standard (SR233377) were separated from plasma by liquid–liquid extraction using dichloromethane after quenching the plasma proteins with acetonitrile. Chromatography was performed on a reversed-phase C18 column using methanol–10 mM phosphate buffer, pH 3.5 (45:55) as mobile phase at a flow-rate of 0.8 ml/min for first 10 min and 1.4 ml/min for the next 15 min with UV–Vis detection at 264 nm and SR233377 as internal standard. The retention times of SR271425 and internal standard were 18.6 and 14.8 min, respectively. The limit of detection was 40 ng/ml and the limit of quantification was 78 ng/ml. This method was also able to detect the three metabolites of SR271425. The intra- and inter-day relative standard deviations were less than 13% at all concentrations. This analytical method was precise and reproducible for pharmacokinetics and metabolism studies of the drug in mice. SR271425 is proceeding to phase I clinical trials in 2001.  相似文献   

11.
The chiral separation of norgestrel enantiomers using reversed-phase high-performance liquid chromatography (RP-HPLC) was studied with hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as chiral mobile phase additive. The effect of mobile phase composition, concentration of HP-beta-CD and column temperature on enantioselective separation were investigated. The quantification properties of the developed RP-HPLC method were examined. A baseline separation of norgestrel enantiomers was achieved on a Agilent ZORBAX Eclipse XDB-C8 column (150 mm x 4.6 mm i.d., 5 microm). The mobile phase was a mixture of acetonitrile and phosphate buffer (pH 5.0, 20 mM) containing 25 mM HP-beta-CD (30:70, v/v) with a flow rate of 1.0 ml/min. The UV detector was set at 240 nm. Calibration curves were linear (n=8) in the range of 0.2-25 microg/ml, the limit of detection and quantitation were 0.10 and 0.20 microg/ml, respectively, for racemic norgestrel. The values of RSD of repeatability and intermediate precision for spiked sample were less than 4.8%. The method was successfully applied to the enantioselective determination of this drug in stereoselective skin permeation study.  相似文献   

12.
In this research project, a high-performance liquid chromatography (HPLC) method was developed for the determination of acyclovir (ACV) in plasma. The plasma samples, recharged with acyclovir and in presence of 5'-N-methylcarboxyamidoadenosine (MECA) as an internal standard, were purified using a solid-phase extraction technique with Waters Oasis HLB columns. The separation of the components from the extract was carried out in a LiChrospher 100 RP-18 column for further ultraviolet detection at a wavelength range of 250-260 nm. The mobile phase composition was 18% acetonitrile, sodium dodecylsulphate 5 mM and phosphate buffer at pH 2.6 with an analysis time of 13 min per sample. The average retention time for acyclovir was of 5.0 min and for the internal standard 11.2 min. The calibration curve was linear ranging between 0.05 and 1.80 microg/ml. The detection limit was 0.006 microg/ml with a quantification limit of 0.020 microg/ml. The ACV recuperation percentage for 250 microl of plasma was between 94.7 and 109.7% with a coefficient of variation not higher than 5.2%. This method was developed and validated for use in bioavailability and bioequivalence studies.  相似文献   

13.
An isocratic high-performance liquid chromatography (HPLC) method was developed and validated to determine Aloe Emodin (AE) in mouse plasma. The analysis required 0.3 ml of plasma and involves extraction with dichloromethane. The HPLC separation was carried out on Symmetry Shield RP18, a mobile phase of methanol-water-acetic acid (65:35:0.2) and fluorescence detection at lambda(ex)=410 nm and lambda(em)=510 nm. The retention time of AE was 11.7 min. The assay was linear from 10 to 1,000 ng/ml (r2 > or = 0.999), showed intra- and inter-day precision within 7.8 and 4.7%, and accuracy of 87.3-105.7%. Detection limit (LOD) and quantification limit (LOQ) were 4.5 and 5 ng/ml, respectively. The method was applied to determine for the first time the pharmacokinetic of AE in mice.  相似文献   

14.
Karenitecin is a novel, highly lipophilic camptothecin derivative with potent anticancer potential. We have developed a sensitive high-performance liquid chromatographic method for the determination of karenitecin concentration in human plasma and urine. Karenitecin was isolated from human plasma and urine using solid-phase extraction. Separation was achieved by gradient elution, using a water and acetonitrile mobile phase, on an ODS analytical column. Karenitecin was detected using fluorescence detection at excitation and emission wavelengths of 370 and 490 nm, respectively. Retention time for karenitecin was 16.2±0.5 min and 8.0±0.2 min for camptothecin, the internal standard. The karenitecin peak was baseline resolved, with the nearest peak at 3.1 min distance. Using normal volunteer plasma and urine from multiple individuals, as well as samples from the 50 patients analyzed to date, no interfering peaks were detected. Inter- and intra-day coefficients of variance were <4.4 and 7.1% for plasma and <4.9 and 11.6% for urine. Assay precision, based on an extracted karenitecin standard plasma sample of 2.5 ng/ml, was +4.46% with a mean accuracy of 92.4%. For extracted karenitecin standard urine samples of 2.5 ng/ml assay precision was +2.35% with a mean accuracy of 99.5%. The mean recovery of karenitecin, at plasma concentrations of 1.0 and 50 ng/ml, was 81.9 and 87.8% respectively. In urine, at concentrations of 1.5 and 50 ng/ml, the mean recoveries were 90.3 and 78.4% respectively. The lower limit of detection (LLD) for karenitecin was 0.5 ng/ml in plasma and 1.0 ng/ml in urine. The lower limit of quantification (LLQ) for karenitecin was 1 ng/ml and 1.5 ng/ml for plasma and urine, respectively. Stability studies indicate that when frozen at −70°C, karenitecin is stable in human plasma for up to 3 months and in human urine for up to 1 month. This method is useful for the quantification of karenitecin in plasma and urine samples for clinical pharmacology studies in patients receiving this agent in clinical trials.  相似文献   

15.
A rapid and simple method was developed for the simultaneous separation and quantification of cloricromene, a coumarine derivative, and its active metabolite, cloricromene acid, in rabbit aqueous humor. The analyses were performed by high-performance liquid chromatography using a C18 reversed-phase column (Hypersil ODS) with UV detection at 318 nm. The mobile phase consisted of acetonitrile-water containing 1% triethylamine pH 3.5, adjusted with orthophosphoric acid. An acetonitrile gradient was necessary to achieve good separation within 13 min. Timolol was found to be a suitable internal standard. The retention times ranged from 5.72 to 11.25 min. A simple pre-treatment with acetonitrile containing 0.6% HCIO4 was used to deproteinize aqueous humor samples. The limit of quantitation ranged between 10 and 20 ng/ml. The recovery was >90%. The relationship between peak areas and concentration was linear over the range between 0.01 and 3.8 microg/ml, with r2 > 0.99. The assay provided good reproducibility and accuracy for both analytes and proved to be suitable for pharmacokinetic studies of cloricromene.  相似文献   

16.
A rapid method for the quantification of amiodarone and desethylamiodarone in animal plasma using high-performance liquid chromatography combined with UV detection (HPLC-UV) is presented. The sample preparation includes a simple deproteinisation step with acetonitrile. In addition, a sensitive method for the quantification of amiodarone and desethylamiodarone in horse plasma and urine using high-performance liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is described. The sample preparation includes a solid-phase extraction (SPE) with a SCX column. Tamoxifen is used as an internal standard for both chromatographic methods. Chromatographic separation is achieved on an ODS Hypersil column using isocratic elution with 0.01% diethylamine and acetonitrile as mobile phase for the HPLC-UV method and with 0.1% formic acid and acetonitrile as mobile phase for the LC-MS/MS method. For the HPLC-UV method, good linearity was observed in the range 0-5 microg ml(-1), and in the range 0-1 microg ml(-1) for the LC-MS/MS method. The limit of quantification (LOQ) was set at 50 and 5 ng ml(-1) for the HPLC-UV method and the LC-MS/MS method, respectively. For the UV method, the limit of detection (LOD) was 15 and 10 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs of the LC-MS/MS method in plasma were much lower, i.e. 0.10 and 0.04 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs obtained for the urine samples were 0.16 and 0.09 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The methods were shown to be of use in horses. The rapid HPLC-UV method was used for therapeutic drug monitoring after amiodarone treatment, while the LC-MS/MS method showed its applicability for single dose pharmacokinetic studies.  相似文献   

17.
Restenosis after angioplasty is thought to be caused by proliferation and migration of vascular smooth muscle cells (VSMCs), and it is a most serious problem in medical treatment. A low dose (50 ng/ml) of manumycin A, an inhibitor of p21(ras) (ras) farnesylation, significantly inhibited proliferation of rat VSMCs stimulated by the platelet-derived growth factor (PDGF). The mitoinhibitory effect of manumycin A was dose- and time-dependent but was independent of cell density. Western blot analysis showed that manumycin A reduced the amount of functional ras localized at the cytoplasmic membrane and inhibited the phosphorylation of p42/44 mitogen-activated protein kinase (MAPK). Manumycin A also inhibited VSMC migration and disorganized alpha actin fibers, as shown by immnofluorecence staining. These results indicate that the interruption of the ras/MAPK signal transduction pathway and the disorganization of alpha actin fibers are the main cause of manumycin A inhibition of VSMC proliferation and migration induced by PDGF.  相似文献   

18.
A highly sensitive and simple high-performance liquid chromatographic (HPLC) assay has been developed and validated for the quantification of dibenzoylmethane (DBM) in rat plasma. DBM and internal standard (I.S.) 1-(5-chloro-2-hydroxy-4-methylphenyl)-3-phenyl-1,3-propanedione (CHMPP) were extracted from rat plasma by ethyl acetate/methanol (95:5, v/v) and analyzed using reverse-phase gradient elution with a Phenomenex Gemini C18 5-mum column. A gradient of mobile phase (mobile phase A: water/methanol (80:20, v/v) with 0.1% TFA and mobile phase B: acetonitrile with 0.1% TFA) at a flow rate of 0.2 mL/min, and ultraviolet (UV) detection at 335 nm were utilized. The lower limit of quantification (LLOQ) using 50 microL rat plasma was 0.05 microg/mL. The calibration curve was linear over a concentration range of 0.05-20 microg/mL. The mean recoveries were 80.6+/-5.7, 83.4+/-1.6 and 77.1+/-3.4% with quality control (QC) level of 0.05, 1 and 20 microg/mL, respectively. Intra- and inter-day assay accuracy and precision fulfilled US FDA guidance for industry bioanalytical method validation. Stability studies showed that DBM was stable in rat plasma after 4h incubation at room temperature, one month storage at -80 degrees C and three freeze/thaw cycles, as well as in reconstitute buffer for 48 h at 4 degrees C. The utility of the assay was confirmed by the successful analysis of plasma samples from DBM pharmacokinetics studies in the rats after oral and intravenous administrations.  相似文献   

19.
An assay was developed to determine concentrations of modafinil (dl-2-[(diphenylmethyl)sulfinyl]acetamide; Provigil) and its two major circulating metabolites, modafinil acid and modafinil sulfone, in human plasma. The assay utilized liquid-liquid extraction of the analytes and an internal standard, (phenylthio)acetic acid, from plasma into a mixture of hexane-dichloromethane-glacial acetic acid (55:45:2, v/v). The analytes were resolved isocratically on a narrow-bore phenyl column at a mobile phase flow-rate of 0.3 ml/min and were monitored by UV detection at 235 nm. The method reported herein reduces the required sample volume of previously reported methods from 1.00 to 0.200 ml of plasma while lowering the limit of quantification (LOQ). The linear range of the assay was from 0.100 to 20.0 microg/ml for each of the three compounds.  相似文献   

20.
Iodixanol is a widely used iso-osmolar contrast medium agent. Similar to iohexol, it can also be a good exogenous marker for the measurement of glomerular filtration rate (GFR). This article describes the development and validation of an HPLC-UV method for quantification of iodixanol in human plasma. Internal standard, iohexol (20 microl, 1 mg/ml), and perchloric acid (30 microl, 20%, v/v) were added to plasma samples (300 microl), followed by neutralization with 10 microl potassium carbonate (5M). Samples were centrifuged and 10 microl of the supernatant was injected onto a C(18) EPS analytical column (3 microm particle size, 150 mm x 4.6 mm). The extraction method yielded >95% recovery for both iodixanol and iohexol. The mobile phase consisted of 0.1% (w/v) sodium formate buffer and acetonitrile. Iohexol and iodixanol peaks were eluted at approximately 5 and 9 min, respectively using a fast gradient method. The assay lower limit of detection was 2.0 microg/ml and lower limit of quantification was 10 microg/ml. The calibration curves, assessed in six replicates, were linear over an iodixanol concentration range of 10-750 microg/ml. Intra- and inter-day accuracy was >95% and precision expressed as % coefficient of variation was <10%. This method is simple, accurate, precise and robust and can potentially be used for iodixanol quantification in large-scale clinical studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号