首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
The presence of PCR inhibitors in water samples is well known and contributes to the fact that a practical PCR assay has not been developed for legionella surveillance. In this study, we devised a new seminested PCR assay for detection of Legionella spp. in water samples as a means of overriding the PCR inhibitors without loss of sensitivity. The seminested PCR assay utilized primers to amplify the 16S rRNA gene (LEG primers) of 39 Legionella spp. The assay was specific to legionellae, and the sensitivity was 1 fg of extracted Legionella DNA in laboratory examination. To evaluate the feasibility and sensitivity of the PCR assay in identifying the presence of legionellae, it was used to survey Legionella contamination in the water of 49 cooling towers of 32 hospitals. A commercially available EnviroAmp Legionella kit and a culture method were also used in the survey for comparison with the seminested PCR assay. The detection rates of legionellae in the samples were 91.8% (45 of 49) by the PCR assay and 79.5% (39 of 49) by the culture method. The EnviroAmp kit revealed that 30.6% of the water samples (15 of 49) contained inhibitors of the PCR amplification. However, the seminested PCR assay could produce the Legionella-specific DNA bands in 14 of the 15 samples. Although 8 of the 14 samples were positive in the first-step PCR, 6 of the 14 samples became positive in the second-step PCR. These results suggest that the effect of PCR inhibitors in samples, if any, can be reduced because of the dilution of the sample in the second-step PCR and that sensitivity of detection can be increased by the second-step PCR. Thus, the seminested PCR assay with LEG primers to amplify the 16S rRNA gene of 39 Legionella spp. was a practical and sensitive method to detect Legionella spp. in water samples.  相似文献   

2.
Isolation of Legionella from water samples using various culture methods   总被引:3,自引:2,他引:1  
The efficacy of a non-selective medium and two selective media were compared for the isolation of legionellas from water samples. The effect of acid wash treatment for decontamination of the water samples on the isolation frequency of legionellas was also studied. The 236 samples were taken from cooling, humidifying and drinking water systems; 21% were legionella-positive when inoculated directly on modified Wadowsky-Yee (MWY) medium and 26% were positive when concentrated (x 200) before cultivation on MWY or CCVC media. Inoculation on MWY medium after concentration followed by decontamination by the acid-wash technique gave the highest isolation frequency (31%). The lowest frequency (8%) was found with the non-selective BCYEα medium. An isolation frequency of 28% was achieved with the BCYEα medium after concentration and acid-wash treatment of the samples. Forty per cent of the samples were positive for legionellas when the results from all the culture methods were combined. Not all the legionella-positive samples were identified by a single culture method. Ninety-three of the 95 positive samples were detected with the two best combinations of three culture methods. The best culture method for detecting legionellas depended on the source of the water sample. Some water quality characteristics, like temperature and organic matter content, affected the isolation frequency of Legionella spp.  相似文献   

3.
Contamination of hospital water systems with legionellae is a well-known cause of nosocomial legionellosis. We describe a new real-time LightCycler PCR assay for quantitative determination of legionellae in potable water samples. Primers that amplify both a 386-bp fragment of the 16S rRNA gene from Legionella spp. and a specifically cloned fragment of the phage lambda, added to each sample as an internal inhibitor control, were used. The amplified products were detected by use of a dual-color hybridization probe assay design and quantified with external standards composed of Legionella pneumophila genomic DNA. The PCR assay had a sensitivity of 1 fg of Legionella DNA (i.e., less than one Legionella organism) per assay and detected 44 Legionella species and serogroups. Seventy-seven water samples from three hospitals were investigated by PCR and culture. The rates of detection of legionellae were 98.7% (76 of 77) by the PCR assay and 70.1% (54 of 77) by culture; PCR inhibitors were detected in one sample. The amounts of legionellae calculated from the PCR results were associated with the CFU detected by culture (r = 0.57; P < 0.001), but PCR results were mostly higher than the culture results. Since L. pneumophila is the main cause of legionellosis, we further developed a quantitative L. pneumophila-specific PCR assay targeting the macrophage infectivity potentiator (mip) gene, which codes for an immunophilin of the FK506 binding protein family. All but one of the 16S rRNA gene PCR-positive water samples were also positive in the mip gene PCR, and the results of the two PCR assays were correlated. In conclusion, the newly developed Legionella genus-specific and L. pneumophila species-specific PCR assays proved to be valuable tools for investigation of Legionella contamination in potable water systems.  相似文献   

4.
Bdellovibrios have been isolated from surface waters but there are no reports of its occurrence in mains water supplies. One hundred and thirty five water samples from 81 sources were examined for the presence of Bdellovibrio bacteriovorus and Legionella spp. Bdellovibrios were isolated by a double-layer agar technique with two strains of Legionella pneumophila serogroup 1 as the host organisms. Bdellovibrio spp. were isolated from 57.8% and Legionella spp. from 9.5% of the samples. The two species occurred together in 4.4% of samples. The incidence of Bdellovibrio spp. and its occurrence with legionellas in man-made water systems is discussed.  相似文献   

5.
Legionella contamination of dental-unit waters.   总被引:9,自引:1,他引:8       下载免费PDF全文
Water samples collected from 28 dental facilities in six U.S. states were examined for the presence of Legionella pneumophila and other Legionella spp. by the PCR-gene probe, fluorescent-antibody microscopic, and viable-plate-count detection methods. The PCR and fluorescent-antibody detection methods, which detect both viable and viable nonculturable Legionella spp., gave higher counts and rates of detection than the plate count method. By the PCR-gene probe detection method, Legionella spp. were detected in 68% of the dental-unit water samples and L. pneumophila was detected in 8%. Concentrations of Legionella spp. in dental-unit water reached 1,000 organisms per ml or more in 36% of the samples, and 19% of the samples were in the category of 10,000/ml or above. L. pneumophila, when present in dental-unit water, never reached concentrations of 1,000/ml or more. Microscopic examination with fluorescent-antibody staining indicated that the contamination was in the dental-unit water lines rather than in the handpieces. Legionella spp. were present in 61% of potable water samples collected for comparative analysis from domestic and institutional faucets and drinking fountains; this percentage was not significantly different from the rate of detection of Legionella spp. in dental-unit water. However, in only 4% of the potable water samples did Legionella spp. reach concentrations of 1,000 organisms per ml, and none was in the 10,000 organisms-per-ml category, and so health-threatening levels of Legionella spp. in potable water were significantly lower than in dental-unit water. L. pneumophila was found in 2% of the potable water samples, but only at the lowest detectable level.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
Bdellovibrios have been isolated from surface waters but there are no reports of its occurrence in mains water supplies. One hundred and thirty five water samples from 81 sources were examined for the presence of Bdellovibrio bacteriovorus and Legion-ella spp. Bdellovibrics were isolated by a double-layer agar technique with two strains of Legionella pneumophila serogroup 1 as the host organisms. Bdellovibrio spp. were isolated from 57·8% and Legionella spp. from 9·5% of the samples. The two species occurred together in 4·4% of samples. The incidence of Bdellovibrio spp. and its occurrence with legionellas in man-made water systems is discussed.  相似文献   

7.
AIMS: To confirm the presence of viable Legionella spp. in dental unit waterlines (DUWL) using fluorescent in situ hybridization (FISH) and compare this method with culture approach and also to validate the utility of an enrichment to increase FISH sensitivity. METHODS AND RESULTS: Water samples from 40 dental units were analysed. Three different techniques for detecting Legionella spp. were compared: (i) culture approach, (ii) direct FISH and (iii) FISH with a previous R2A medium enrichment (R2A/FISH). The FISH detection was confirmed by PCR. The use of the direct FISH does not improve significantly the detection of legionellae when compared with the culture. On the contrary, when R2A/FISH was performed, sensitivity was, respectively, two- and threefold higher than that with the direct FISH and culture approach. Using R2A/FISH, 63% of water samples analysed showed a contamination by legionellae. CONCLUSIONS: Legionellae detection by direct FISH and R2A/FISH in dental unit water is possible but is more rapid and more sensitive (R2A/FISH) than the culture approach. SIGNIFICANCE AND IMPACT OF THE STUDY: R2A/FISH showed that several pathogens present in DUWL are viable but may not be culturable. Unlike PCR, R2A/FISH is designed to detect only metabolically active cells and therefore provides more pertinent information on infectious risk.  相似文献   

8.
A new real-time PCR assay was developed and validated in combination with an immunomagnetic separation system for the quantitative determination of Legionella pneumophila in water samples. Primers that amplify simultaneously an 80-bp fragment of the dotA gene from L. pneumophila and a recombinant fragment including a specific sequence of the gyrB gene from Aeromonas hydrophila, added as an internal positive control, were used. The specificity, limit of detection, limit of quantification, repetitivity, reproducibility, and accuracy of the method were calculated, and the values obtained confirmed the applicability of the method for the quantitative detection of L. pneumophila. Moreover, the efficiency of immunomagnetic separation in the recovery of L. pneumophila from different kinds of water was evaluated. The recovery rates decreased as the water contamination increased (ranging from 59.9% for distilled water to 36% for cooling tower water), and the reproducibility also decreased in parallel to water complexity. The feasibility of the method was evaluated by cell culture and real-time PCR analysis of 60 samples in parallel. All the samples found to be positive by cell culture were also positive by real-time PCR, while only eight samples were found to be positive only by PCR. Finally, the correlation of both methods showed that the number of cells calculated by PCR was 20-fold higher than the culture values. In conclusion, the real-time PCR method combined with immunomagnetic separation provides a sensitive, specific, and accurate method for the rapid quantification of L. pneumophila in water samples. However, the recovery efficiency of immunomagnetic separation should be considered in complex samples.  相似文献   

9.
Modifications to the EnviroAmp Legionella detection system are described which permit the rapid analysis of bacterial colonies taken from Legionella selective media. Capillary PCR permitted twice the number of samples to be analysed with a single kit. When PCR was positive for Leg. pneumophila , this result was confirmed by seroagglutination. The reverse dot blot hybridization assay was only used where PCR indicated a Legionella sp. other than Leg. pneumophila , permitting further savings on detection system components. This technique and standard confirmation procedures were applied to 133 isolates arising from 63 water samples plated to Legionella isolation media. Results agreed except for two isolates which gave a positive result for Legionella spp. by PCR and hybridization but were negative using standard procedures. Raising the annealing/extension temperature of the PCR by 2 °C eliminated the false positive result with these two isolates but did not adversely effect the sensitivity of the assay, as determined by re-testing of 68 environmental isolates and testing of 69 new environmental isolates and 12 Legionella reference species. The modified technique provides a convenient and cost effective alternative to standard confirmation procedures.  相似文献   

10.
Reclaimed water is an important resource for areas with inadequate water supplies. However, there have been few studies on the variety of microorganisms found in this type of water, since typically reclaimed water is examined only for the presence of coliform bacteria. Many microorganisms, including the legionellae, are known to be more resistant to chlorine than are coliform bacteria. Previously, we detected > 10(3) Legionella cells per ml in primary and secondary sewage effluents and observed no significant reduction in population numbers throughout the treatment process. In this study, we detected Legionella spp. in chlorinated effluent by using an EnviroAmp Legionella PCR kit and direct fluorescent antibody (DFA) staining. However, we were not able to isolate Legionella spp. from either natural or seeded reclaimed water samples. This suggests that the Legionella spp. detected by the PCR and DFA methods may be injured or viable but nonculturable after exposure to the high residual chlorine levels typically found in this type of water source. The numbers of coliform bacteria were low (< 2 cells per 100 ml) in most reclaimed water samples and were not correlated with the presence or absence of Legionella spp. We also collected air samples from above a secondary aeration basin and analyzed them by using the PCR, DFA, and plate culture methods. Legionella spp. were detected in the air obtained from above the secondary basin with all three methods. We concluded that the PCR was superior to the culture and DFA methods for detecting Legionella spp. in environmental water samples.  相似文献   

11.
Abstract Using direct fluorescent antibody (DFA) staining technique, Legionella pneumophila SG 1, 3 and 5 was evident in water samples collected from different localities of central Italian regions, Marche and Abruzzi; L. pneumophila SG 1 and 3 was also detected in aquatic stages of arthropods living in the Legionella -positive waters. Diptera, Coleoptera, Collembola and Isopoda were found to be positive for legionellas by DFA. Diptera, the most common in the waters surveyed, were represented by Chironomidae and Culicidae families, the latter being larval and pupal stages of genus Anopheles and Culex . Mosquito adults, emerged in laboratory from pupae collected in one sample of positive water, were also positive. The findings that aquatic arthropods harbor legionellas and whether they could be involved in the maintenance and dissemination of legionellas in nature are discussed.  相似文献   

12.
A new real-time PCR assay was developed and validated in combination with an immunomagnetic separation system for the quantitative determination of Legionella pneumophila in water samples. Primers that amplify simultaneously an 80-bp fragment of the dotA gene from L. pneumophila and a recombinant fragment including a specific sequence of the gyrB gene from Aeromonas hydrophila, added as an internal positive control, were used. The specificity, limit of detection, limit of quantification, repetitivity, reproducibility, and accuracy of the method were calculated, and the values obtained confirmed the applicability of the method for the quantitative detection of L. pneumophila. Moreover, the efficiency of immunomagnetic separation in the recovery of L. pneumophila from different kinds of water was evaluated. The recovery rates decreased as the water contamination increased (ranging from 59.9% for distilled water to 36% for cooling tower water), and the reproducibility also decreased in parallel to water complexity. The feasibility of the method was evaluated by cell culture and real-time PCR analysis of 60 samples in parallel. All the samples found to be positive by cell culture were also positive by real-time PCR, while only eight samples were found to be positive only by PCR. Finally, the correlation of both methods showed that the number of cells calculated by PCR was 20-fold higher than the culture values. In conclusion, the real-time PCR method combined with immunomagnetic separation provides a sensitive, specific, and accurate method for the rapid quantification of L. pneumophila in water samples. However, the recovery efficiency of immunomagnetic separation should be considered in complex samples.  相似文献   

13.
A cross-sectional multicenter survey of Italian hotels was conducted to investigate Legionella spp. contamination of hot water. Chemical parameters (hardness, free chlorine concentration, and trace element concentrations), water systems, and building characteristics were evaluated to study risk factors for colonization. The hot water systems of Italian hotels were strongly colonized by Legionella; 75% of the buildings examined and 60% of the water samples were contaminated, mainly at levels of > or =10(3) CFU liter(-1), and Legionella pneumophila was the most frequently isolated species (87%). L. pneumophila serogroup 1 was isolated from 45.8% of the contaminated sites and from 32.5% of the hotels examined. When a multivariate logistic model was used, only hotel age was associated with contamination, but the risk factors differed depending on the contaminating species and serogroup. Soft water with higher chlorine levels and higher temperatures were associated with L. pneumophila serogroup 1 colonization, whereas the opposite was observed for serogroups 2 to 14. In conclusion, Italian hotels, particularly those located in old buildings, represent a major source of risk for Legionnaires' disease due to the high frequency of Legionella contamination, high germ concentration, and major L. pneumophila serogroup 1 colonization. The possible role of chlorine in favoring the survival of Legionella species is discussed.  相似文献   

14.
Legionella spp. are ubiquitous in most environmental water sources; however, sewage treatment plants have not been examined as potential environmental reservoirs for these bacteria. This study used polymerase chain reaction, direct fluorescent-antibody staining, and culture methods to examine raw and treated sewage, ocean-receiving waters, and nearshore coastal environments for the presence of Legionella pneumophila and other Legionella spp. The study concluded that Legionella spp. are present in all phases of sewage treatment and that population numbers do not significantly decline through the treatment process. Ocean-receiving waters located 5 miles offshore, where the treated sewage is discharged, were found to contain Legionella spp., but ocean water between the discharge site and coastal bathing beaches was negative. This suggests that the Legionella spp. from the ocean discharge site were not reaching the nearshore beach waters. A flood control channel and river that entered the ocean were found to contain Legionella spp., and a nearby beach swimming area was also found to be positive, suggesting that land runoff from the flood control channel and river were the source of the Legionella spp. in the beach water samples that tested positive.  相似文献   

15.
AIMS: To compare the sensitivities of two nested PCR assays for the detection of Legionella pneumophila to each other and to the plate counting technique (ISO 11731) in a wide range of aquatic samples. METHODS AND RESULTS: The nested PCR assay with the primer set LEG 225-LEG 858 revealed 56% of the 46 analysed aquatic samples as being positive for Legionella spp., while the primer set JFP-JRP yielded 98% positive samples. The detection was confirmed by sequencing the PCR products. These results are considerably higher than the result obtained with the plate counting technique (41%), indicating the higher sensitivity of PCR-based diagnostic methods. As the PCR assay with the LEG 225-LEG 858 primer set resulted in a lower number of positive samples, it is considered not sensitive enough for aquatic samples. Similar results for the respective primer sets were obtained for the detection of the species L. pneumophila, responsible for 90% of all human Legionella infections, in the aquatic samples analysed. Both microbial community analysis by PCR-denaturing gradient gel electrophoresis and the analysis of biotic and abiotic water quality parameters revealed no relation between L. pneumophila-positive and -negative samples and the physico-chemical and bacteriological characteristics of the aquatic samples. CONCLUSIONS: The results show the additional value of the PCR assay with the JFP-JRP primer set compared with the plate counting technique, as well as its applicability in a wide range of aquatic samples. SIGNIFICANCE AND IMPACT OF THE STUDY: This study shows the importance of comparing different primer sets for nested PCR assays for the detection of L. pneumophila in aquatic samples, as well as the lower sensitivity of the widely accepted plate counting technique (ISO 11731).  相似文献   

16.
A sensitive and specific method has been developed to enumerate viable L. pneumophila and other Legionella spp. in water by epifluorescence microscopy in a short period of time (a few hours). This method allows the quantification of L. pneumophila or other Legionella spp. as well as the discrimination between viable and nonviable Legionella. It simultaneously combines the specific detection of Legionella cells using antibodies and a bacterial viability marker (ChemChrome V6), the enumeration being achieved by epifluorescence microscopy. The performance of this immunological double-staining (IDS) method was investigated in 38 natural filterable water samples from different aquatic sources, and the viable Legionella counts were compared with those obtained by the standard culture method. The recovery rate of the IDS method is similar to, or higher than, that of the conventional culture method. Under our experimental conditions, the limit of detection of the IDS method was <176 Legionella cells per liter. The examination of several samples in duplicates for the presence of L. pneumophila and other Legionella spp. indicated that the IDS method exhibits an excellent intralaboratory reproducibility, better than that of the standard culture method. This immunological approach allows rapid measurements in emergency situations, such as monitoring the efficacy of disinfection shock treatments. Although its field of application is as yet limited to filterable waters, the double-staining method may be an interesting alternative (not equivalent) to the conventional standard culture methods for enumerating viable Legionella when rapid detection is required.  相似文献   

17.
Contamination of hospital water systems with legionellae is a well-known cause of nosocomial legionellosis. We describe a new real-time LightCycler PCR assay for quantitative determination of legionellae in potable water samples. Primers that amplify both a 386-bp fragment of the 16S rRNA gene from Legionella spp. and a specifically cloned fragment of the phage lambda, added to each sample as an internal inhibitor control, were used. The amplified products were detected by use of a dual-color hybridization probe assay design and quantified with external standards composed of Legionella pneumophila genomic DNA. The PCR assay had a sensitivity of 1 fg of Legionella DNA (i.e., less than one Legionella organism) per assay and detected 44 Legionella species and serogroups. Seventy-seven water samples from three hospitals were investigated by PCR and culture. The rates of detection of legionellae were 98.7% (76 of 77) by the PCR assay and 70.1% (54 of 77) by culture; PCR inhibitors were detected in one sample. The amounts of legionellae calculated from the PCR results were associated with the CFU detected by culture (r = 0.57; P < 0.001), but PCR results were mostly higher than the culture results. Since L. pneumophila is the main cause of legionellosis, we further developed a quantitative L. pneumophila-specific PCR assay targeting the macrophage infectivity potentiator (mip) gene, which codes for an immunophilin of the FK506 binding protein family. All but one of the 16S rRNA gene PCR-positive water samples were also positive in the mip gene PCR, and the results of the two PCR assays were correlated. In conclusion, the newly developed Legionella genus-specific and L. pneumophila species-specific PCR assays proved to be valuable tools for investigation of Legionella contamination in potable water systems.  相似文献   

18.
Aims: This study was designed to evaluate the usefulness of quantification by real‐time PCR as a management tool to monitor concentrations of Legionella spp. and Legionella pneumophila in industrial cooling systems and its ability to anticipate culture trends by the French standard method (AFNOR T90‐431). Methods and Results: Quantifications of Legionella bacteria were achieved by both methods on samples from nine cooling systems with different water qualities. Proportion of positive samples for L. pneumophila quantified by PCR was clearly lower in deionized or river waters submitted to a biocide treatment than in raw river waters, while positive samples for Legionella spp. were quantified for almost all the samples. For some samples containing PCR inhibitors, high quantification limits (up to 4·80 × 105 GU l?1) did not allow us to quantify L. pneumophila, when they were quantified by culture. Finally, the monitoring of concentrations of L. pneumophila by both methods showed similar trends for 57–100% of the samples. Conclusions: These results suggest that, if some methodological steps designed to reduce inhibitory problems and thus decrease the quantification limits, could be developed to quantify Legionella in complex waters, the real‐time PCR could be a valuable complementary tool to monitor the evolution of L. pneumophila concentrations. Significance and Impact of the Study: This study shows the possibility of using real‐time PCR to monitor L. pneumophila proliferations in cooling systems and the importance to adapt nucleic acid extraction and purification protocols to raw waters.  相似文献   

19.
A multiplex PCR technique was compared with standard bacteriological techniques for the detection of Salmonella , and Salm. enteritidis in particular, in samples of chicken skin obtained from retail outlets. Five of 68 samples were positive by both systems (7.4%), 58 of 68 were negative by both systems (85%), five were positive by PCR only (7.4%) but none were positive by culture only. The PCR was quicker and more sensitive than the bacteriological methods, finding 15% of samples positive for Salmonella compared to 7.4%, and taking less than 24 h to reach a result as opposed to 2–3 d.  相似文献   

20.
Isothermal nucleic acid sequence-based amplification (NASBA) was applied to detect Legionella 16S rRNA. The assay was originally developed as a Legionella pneumophila conventional NASBA assay with electrochemiluminescence (ECL) detection and was subsequently adapted to a L. pneumophila real-time NASBA format and a Legionella spp. real-time NASBA using molecular beacons. L. pneumophila RNA prepared from a plasmid construct was used to assess the analytical sensitivity of the assay. The sensitivity of the NASBA assay was 10 molecules of in vitro wild type L. pneumophila RNA and 0.1-1 colony-forming units (CFU) of L. pneumophila. In spiked respiratory specimens, the sensitivity of the NASBA assays was 1-10000 CFU of L. pneumophila serotype 1 depending on the background. After dilution of the nucleic acid extract prior to amplification, 1-10 CFU of L. pneumophila serotype 1 could be detected with both detection methods. Finally, 27 respiratory specimens, well characterized by culture and PCR, collected during a L. pneumophila outbreak, were tested by conventional and real-time NASBAs. All 11 PCR positive samples were positive by conventional NASBA, 9/11 and 10/11 were positive by L. pneumophila real-time NASBA and Legionella spp. real-time NASBA, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号