首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
This work describes the development of an automated flow-based biosensor that employs genetically modified acetylcholinesterase (AChE) enzymes B394, B4 and wild type B131. The biosensor was based on a screen printed carbon electrode (SPE) that was integrated into a flow cell. Enzymes were immobilised on cobalt (II) phthalocyanine (CoPC) modified electrodes by entrapment in a photocrosslinkable polymer (PVA-AWP). The automated flow-based biosensor was successfully used to quantify three organophosphate pesticides (OPs) in milk samples. The OPs used were chlorpyriphos-oxon (CPO), ethyl paraoxon (EPOx) and malaoxon (MOx). The total analysis time for the assay was less than 15 min. Initially, the biosensor performance was tested in phosphate buffer solution (PBS) using B394, B131 and B4 biosensors. The best detection limits were obtained with B394; therefore, this biosensor was used to produce calibration data in milk with three OPs in the concentration range of 5 × 10(-6)M to 5 × 10(-12)M. The limit of detection (LOD) obtained in milk for CPO, EPOx and MOx were 5 × 10(-12)M, 5 × 10(-9)M and 5 × 10(-10)M, respectively, with a correlation coefficient R(2)=0.9910. The automated flow-based biosensor successfully quantified the OPs in different fat-containing milk samples. There were no false positives or false negatives observed for the analytical figures of merit for the constructed biosensors. This method is inexpensive, sensitive, portable, non-invasive and provides real-time results. This analytical system can provide rapid detection of highly toxic OPs in food matrices such as milk.  相似文献   

2.
We report a biosensor based on organophosphorus hydrolase (OPH) multilayer modified microcantilever (MCL) for detection of organophosphorus compounds (OPs). The assay is based on substrate-dependent bending of the OPH functionalized MCLs. The cantilever bending amplitude at equilibrium was a function of the concentration of paraoxon with the dynamic range extending from 10(-7) to 10(-3)M. The lower detection limit of approximately 10(-7)M for paraoxon was an order of magnitude better than the OPH-based potentiometric and optical biosensors based on pH modulation. There was a good intra-sensor and an acceptable inter-sensor reproducibility as evidenced by the standard errors of 5% and 15%, respectively. OPs measured using this technique included parathion and diisopropyl fluorophosphate (DFP) in the order of paraoxon>DFP>parathion. The conformational change of the OPH was most likely the main origin of MCL bending.  相似文献   

3.
Pesticides released intentionally into the environment and through various processes contaminate the environment. Although pesticides are associated with many health hazards, there is a lack of monitoring of these contaminants. Traditional chromatographic methods-high-performance liquid chromatography, capillary electrophoresis, and mass spectrometry-are effective for the analysis of pesticides in the environment but have certain limitations such as complexity, time-consuming sample preparation, and the requirement of expensive apparatus and trained persons to operate. Over the past decades, acetylcholinesterase (AChE) inhibition-based biosensors have emerged as simple, rapid, and ultra-sensitive tools for pesticide analysis in environmental monitoring, food safety, and quality control. These biosensors have the potential to complement or replace the classical analytical methods by simplifying or eliminating sample preparation and making field-testing easier and faster with significant decrease in cost per analysis. This article reviews the recent developments in AChE inhibition-based biosensors, which include various immobilization methods, different strategies for biosensor construction, the advantages and roles of various matrices used, analytical performance, and application methods for constructing AChE biosensors. These AChE biosensors exhibited detection limits and linearity in the ranges of 1.0×10(-11) to 42.19 μM (detection limits) and 1.0×10(-11)-1.0×10(-2) to 74.5-9.9×10(3)μM (linearity). These biosensors were stable for a period of 2 to 120days. The future prospects for the development of better AChE biosensing systems are also discussed.  相似文献   

4.
The spherical porous Pd nanoparticle assemblies (NPAs) have been successfully synthesized by starch-assisted chemical reduction of Pd(II) species at room temperature. Such Pd NPAs are not simply used to enlarge the surface area and to promote the electron transfer. They also catalyze the reduction of H(2)O(2) which are regarded as horseradish peroxidase (HRP) substitutes in electron transfer process. By using them as electrocatalysts, as low as 6.8×10(-7) M H(2)O(2) can be detected with a linear range from 1.0×10(-6) to 8.2×10(-4) M. Moreover, through co-immobilization of such Pd NPAs and glucose oxidase (GOx), a sensitive and selective glucose biosensor is developed. The detection principle lies on measuring the increase of cathodic current by co-reduction of dissolved oxygen and the in situ generated H(2)O(2) during the enzymatic reaction. Under optimal conditions, the detection limit is down to 6.1×10(-6) M with a very wide linear range from 4.0×10(-5) to 2.2×10(-2) M. The proposed biosensor shows a fast response, good stability, high selectivity and reproducibility of serum glucose level. It provides a promising strategy to construct fast, sensitive, stable and anti-interferential amperometric biosensors for early diagnosis and prevention of diabetes.  相似文献   

5.
This study describes the development of amperometric sensors based on poly(allylamine hydrochloride) (PAH) and lutetium bisphthalocyanine (LuPc(2)) films assembled using the Layer-by-Layer (LbL) technique. The films have been used as modified electrodes for catechol quantification. Electrochemical measurements have been employed to investigate the catalytic properties of the LuPc(2) immobilized in the LbL films. By chronoamperometry, the sensors present excellent sensitivity (20 nA μM(-1)) in a wide linear range (R(2)=0.994) up to 900 μM and limit of detection (s/n=3) of 37.5 × 10(-8)M for catechol. The sensors have good reproducibility and can be used at least for ten times. The work potential is +0.3 V vs. saturated calomel electrode (SCE). In voltammetry measurements, the calibration curve shows a good linearity (R(2)=0.992) in the range of catechol up to 500 μM with a sensitivity of 90 nA μM(-1) and LD of 8 μM.  相似文献   

6.
This work describes development and optimization of a generic method for the immobilization of enzymes in chemically synthesized gold polypyrrole (Au-PPy) nanocomposite and their application in amperometric biosensors. Three enzyme systems have been used as model examples: cytochrome c, glucose oxidase and polyphenol oxidase. The synthesis and deposition of the nanocomposite was first optimized onto a glassy carbon electrode (GCE) and then, the optimum procedure was used for enzyme immobilization and subsequent fabrication of glucose and phenol biosensors. The resulting nanostructured polymer strongly adheres to the surface of the GCE electrode, has uniform distribution and is very stable. The method has proved to be an effective way for stable enzyme attachment while the presence of gold nanoparticles provides enhanced electrochemical activity; it needs very small amounts of pyrrole and enzyme and the Au-PPy matrix avoids enzyme leaking. The preparation conditions, Michaelis-Menten kinetics and analytical performance characteristics of the two biosensors are discussed. Optimization of the experimental parameters was performed with regard to pyrrole concentration, enzyme amount, pH and operating potential. These biosensors resulted in rapid, simple, and accurate measurement of glucose and phenol with high sensitivities (1.089 mA/M glucose and 497.1 mA/M phenol), low detection limits (2 x 10(-6)M glucose and 3 x 10(-8)M phenol) and fast response times (less than 10s). The biosensors showed an excellent operational stability (at least 100 assays) and reproducibility (R.S.D. of 1.36%).  相似文献   

7.
This paper describes the use of the electrostatic layer-by-layer (LbL) technique for the preparation of bioanodes with potential application in ethanol/O(2) biofuel cells. More specifically, the LbL technique was employed for immobilization of dehydrogenase enzymes and polyamidoamine (PAMAM) dendrimers onto carbon paper support. Both mono (anchoring only the enzyme alcohol dehydrogenase, ADH) and bi-enzymatic (anchoring both ADH and aldehyde dehydrogenase, AldDH) systems were tested. The amount of ADH deposited onto the Toray? paper was 95 ng cm(-2) per bilayer. Kinetic studies revealed that the LbL technique enables better control of enzyme disposition on the bioanode, as compared with the results obtained with the bioanodes prepared by the passive adsorption technique. The power density values achieved for the mono-enzymatic system as a function of the enzyme load ranged from 0.02 to 0.063 mW cm(-2) for the bioanode containing 36 ADH bilayers. The bioanodes containing a gas diffusion layer (GDL) displayed enhanced performance, but their mechanical stability must be improved. The bi-enzymatic system generated a power density of 0.12 mW cm(-2). In conclusion, the LbL technique is a very attractive approach for enzyme immobilization onto carbon platform, since it enables strict control of enzyme disposition on the bioanode surface with very low enzyme consumption.  相似文献   

8.
A potentiometric biosensor based on urease was developed for the quantitative determination of urea concentration in aqueous solutions for biomedical applications. The urease was either physisorbed onto an electrodeposited polyaniline film (PANI), or immobilized on a layer-by-layer film (LbL) assembled over the PANI film, that was obtained by the alternate deposition of charged polysaccharides (carboxymethylpullulan (CMP) and chitosan (CHI)). In the latter case, the urease (Urs) enzyme was either physically adsorbed or covalently grafted to the LbL film using carbodiimide coupling reaction. Potentiometric responses of the enzymatic biosensors were measured as a function of the urea concentration in aqueous solutions (from 10(-6) to 10(-1) mol L(-1) urea). Very high sensitivity and short response time were observed for the present biosensor. Moreover, a stability study showed a higher stability over time for the potentiometric response of the sensor with the enzyme-grafted LbL film, testifying for the protective nature of the polysaccharide coating and the interest of covalent grafting.  相似文献   

9.
An acetylcholine-selective electrode based on a plasticized polymeric membrane has been developed. The electrode exhibited good selectivity for acetylcholine (ACh) over choline and some common ions, low drift, and a fast response to ACh. The response was linear over an ACh concentration range of 1×10(-6) to 1×10(-3) M with a slope of 59.1±0.1 and a detection limit of 1.5×10(-7)±1.2×10(-8) M. The electrode was used to monitor enzymatic ACh hydrolysis catalyzed by acetylcholinesterase (AChE) at different substrate and enzyme concentrations. A kinetic data analysis permitted the determination of the Michaelis-Menten constant of the enzymatic hydrolysis and AChE activity in the range of 2×10(-5) to 3.8×10(-1)U ml(-1).  相似文献   

10.
The detection of aromatic compounds from pesticides and industrial wastewater has become of great interest, since these compounds withstand chemical oxidation and biological degradation, accumulating in the environment. In this work, a highly sensitive biosensor for detecting catechol was obtained with the immobilization of Cl-catechol 1,2-dioxygenase (CCD) in nanostructured films. CCD layers were alternated with poly(amidoamine) generation 4 (PAMAM G4) dendrimer using the electrostatic layer-by-layer (LbL) technique. Circular dichroism (CD) measurements indicated that the immobilized CCD preserved the same conformation as in solution. The thickness of the very first CCD layers in the LbL films was estimated at ca. 3.6 nm, as revealed by surface plasmon resonance (SPR). PAMAM/CCD 10-bilayer films were employed in detecting diluted catechol solutions using either an optical or electrical approach. Due to the mild immobilization conditions employed, especially regarding the pH and ionic strength of the dipping solutions, CCD remained active in the films for periods longer than 3 weeks. The optical detection comprised absorption experiments in which the formation of cis-cis muconic acid, resulting from the reaction between CCD and catechol, was monitored by measuring the absorbance at 260 nm after film immersion in catechol solutions. The electrical detection was carried out using LbL films deposited onto gold-interdigitated electrodes immersed in aqueous solutions at different catechol concentrations. Using impedance spectroscopy in a broad frequency range (1Hz-1kHz), we could detect catechol in solutions at concentrations as low as 10(-10) M.  相似文献   

11.
This paper describes the preparation of a biomimetic Langmuir-Blodgett film of tyrosinase incorporated in a lipidic layer and the use of lutetium bisphthalocyanine as an electron mediator for the voltammetric detection of phenol derivatives, which include one monophenol (vanillic acid), two diphenols (catechol and caffeic acid) and two triphenols (gallic acid and pyrogallol). The first redox process of the voltammetric responses is associated with the reduction of the enzymatically formed o-quinone and is favoured by the lutetium bisphthalocyanine because significant signal amplification is observed, while the second is associated with the electrochemical oxidation of the antioxidant and occurs at lower potentials in the presence of an electron mediator. The biosensor shows low detection limit (1.98×10(-6)-27.49×10(-6) M), good reproducibility, and high affinity to antioxidants (K(M) in the range of 62.31-144.87 μM). The excellent functionality of the enzyme obtained using a biomimetic immobilisation method, the selectivity afforded by enzyme catalysis, the signal enhancement caused by the lutetium bisphthalocyanine mediator and the increased selectivity of the curves due to the occurrence of two redox processes make these sensors exceptionally suitable for the detection of phenolic compounds.  相似文献   

12.
A Tb(3+)-promoted G-quadruplex-hemin DNAzyme was first reported in here. We demonstrated that trace Tb(3+) is able to induce guanine-rich DNA (5'-TGGGTAGGGCGGGTTGGGAAA-3') folding into a compact antiparallel G-quadruplex structure and thus allows the formation of G-quadruplex-hemin DNAzyme. The proposed DNAzyme can effectively catalyze the H(2)O(2)-mediated oxidation of TMB (3,3',5,5'-tetramethylbenzidine sulfate) and leads to a change from colorless to blue in solution color, which provides a sensing platform for the label-free visual detection of Tb(3+). Using above sensing platform, a selective and sensitive label-free visual method for the detection of trace Tb(3+) was developed. The proposed method can be used to detect as low as 1.13×10(-7) M of Tb(3+) by the naked eyes observation and 9.0×10(-9) M of Tb(3+) by UV-vis spectrophotometry with a better stability and reproducibility. Compared with K(+)-promoted G-quadruplex-hemin DNAzyme reported in previous study, the novel Tb(3+)-promoted G-quadruplex-hemin DNAzyme has much higher peroxidase activity and better specificity, which lead to a great potential in the development of optical, electrochemical and chemiluminescence DNAzyme-based biosensors.  相似文献   

13.
The biocatalytic growth of gold nanoparticles (Au-NPs) has been employed in the design of new optical biosensors based on the enhanced resonance light scattering (RLS) signals. Both absorption spectroscopy and transmission electron microscopy (TEM) analysis revealed Au-NP seeds could be effectively enlarged upon the reaction with H(2)O(2), an important metabolite that could be generated by many biocatalytic reactions. Upon the stepwise enlargement of Au-NPs, the light scattering intensity could be greatly enhanced, which then allowed the quantitative detection of the analyte, H(2)O(2). Further combination of the biocatalytic reaction that can yield H(2)O(2) by using the enzyme, glucose oxidase, with the enlargement of Au-NPs enabled the design of a sensitive glucose biosensor using the RLS technique. In the present study, we could achieve the detection of glucose in a linear range of 1.0 x 10(-6) M to 1.1 x 10(-4) M, with detection limit of 6.8 x 10(-7) M.  相似文献   

14.
In this paper, we report a sensitive and selective method for detection of organophosphorus compounds (OPs) based on Mn:ZnSe d-dots-enzyme-hydrogen peroxide (H(2)O(2)) fluorescence quenching system. Acetylcholine esterase (AChE) can hydrolyze acetylcholine (ACh) to choline. Subsequently, choline oxidase (ChOx) oxidizes choline to generate H(2)O(2). The enzyme-generated H(2)O(2) can quench the fluorescence of Mn:ZnSe d-dots. When paraoxon are introduced in solution, it can interact with the active centers of AChE and decrease the enzyme activity. This leads to the decrease of the H(2)O(2) production and then the fluorescence quenching rate of Mn:ZnSe d-dots. Experimental results showed that the enzyme inhibition percentage of Mn:ZnSe d-dots-ChOx-AChE-ACh system was proportional to the logarithm of paraoxon in the range 4.84×10(-11) to 4.84×10(-6) mol/L with the detection limit (S/N=3) of 1.31×10(-11) mol/L. The proposed biosensor has been employed for quick determination of paraoxon in tap water and milk samples with satisfactory reproducibility and accuracy. This nano-biosensor was proved to be sensitive, rapid, simple and tolerance of most interfering substances.  相似文献   

15.
A novel enzymatic hydrogen peroxide sensor was successfully fabricated based on the nanocomposites containing of Ag/C nanocables and gold nanoparticles (AuNPs). Ag/C nanocables have been synthesized by a hydrothermal method and then AuNPs were assembled on the surface of Ag/C nanocables. The nanocomposites were confirmed by X-ray diffraction (XRD), transmission electron microscopy (TEM), scanning electron microscopy (SEM) and energy-dispersive X-ray spectrometry (EDS). The above nanocomposites have satisfactory chemical stability and excellent biocompatibility. Cyclic voltammetry (CV) was used to evaluate the electrochemical performance of the Ag/C/Au nanocomposites at glassy carbon electrode (GCE). The results indicated that the Ag/C/Au nanocomposites exhibited excellent electrocatalytic activity to the reduction of H(2)O(2). It offered a linear range of 6.7×10(-9) to 8.0×10(-6) M, with a detection limit of 2.2×10(-9) M. The apparent Michaelis-Menten constant of the biosensor was 51.7×10(-6) M. These results indicated that Ag/C/Au nanocomposites have potential for constructing of a variety of electrochemical biosensors.  相似文献   

16.
Organophosphorus pesticides (OP) are highly toxic and are widely used as insecticides. Bacterial organophosphohydrolases which hydrolyze a variety of OPs have been considered for the clean-up of polluted environments. This study describes the engineering of Escherichia coli towards the overproduction of the organophosphohydrolase (OpdA) from Agrobacterium radiobacter at the surface of polyester inclusions. The OpdA was N-terminally fused via a designed linker region to the C-terminus of polyester inclusion-forming enzyme PhaC of Ralstonia eutropha. The PhaC-L-OpdA fusion protein was overproduced by using the strong T7 promoter and when coexpressed with genes phaA (encoding β-ketothiolase) and phaB (encoding acetoacetyl-CoA reductase) from R. eutropha this led to formation of polyester inclusions abundantly displaying OpdA. These OpdA beads showed organophosphohydrolase activity of 1,840 U/g wet polyester beads or 4,412 U/g protein. Steady state kinetics revealed that when compared with free OpdA the k(cat) (s(-1)) of 139 of immobilized OpdA was reduced by about 16.5-fold while the K(M) (M) of 2.5 × 10(-4) was increased by 1.6-fold. The immobilized OpdA showed increased temperature stability. Moreover, the stability of OpdA immobilized to polyester beads was assessed by incubating OpdA beads at 25°C for up to 11 days and no significant loss in enzyme activity was detected. The application performance of the OpdA beads with respect to hydrolysis of OPs in contaminated environments was demonstrated in wool scour spiked with fluorescent coumaphos. This study demonstrated a new strategy toward the efficient recombinant production of immobilized organophosphohydrolase, the OpdA, suitable for bioremediation applications.  相似文献   

17.
A novel enzyme-linked DNA hybridization assay on an interdigitated array (IDA) microelectrode integrated into a microfluidic channel is demonstrated with sub-nM detection limit. To improve the detection limit as compared to conventional electrochemical biosensors, a recyclable redox product, 4-aminophenol (PAP) is used with an IDA microelectrode. The IDA has a modest and easily fabricated inter-digit spacing of 10 μm, yet we were able to demonstrate 97% recycling efficiency of PAP due to the integration in a microfluidic channel. With a 70 nL sample volume, the characterized detection limit for PAP of 1.0 × 10?1? M is achieved, with a linear dynamic range that extends from 1.0 × 10?? to 1.0 × 10?? M. This detection limit, which is the lowest reported detection limit for PAP, is due to the increased sensitivity provided by the sample confinement in the microfluidic channel, as well as the increased repeatability due to perfectly static flow in the microchannel and an additional anti-fouling step in the protocol. DNA sequence detection is achieved through a hybridization sandwich of an immobilized complementary probe, the target DNA sequence, and a second complementary probe labeled with β-galactosidase (β-GAL); the β-GAL converts its substrate, 4-aminophenyl-d-galactopyranoside (PAPG), into PAP. In this report we present the lowest reported observed detection limit (1.0 × 10?1? M) for an enzyme-linked DNA hybridization assay using an IDA microelectrode and a redox signaling paradigm. Thus, we have demonstrated highly sensitive detection of a targeted DNA sequence using a low-cost easily fabricated electrochemical biosensor integrated into a microfluidic channel.  相似文献   

18.
Charge-detecting biosensors have recently become the focal point of biosensor research, especially research onto organic thin-film transistors (OTFTs), which combine compactness, a low cost, and fast and label-free detection to realize simple and stable in vivo diagnostic systems. We fabricated organic pentacene-based bottom-contact thin-film transistors with an ultra-thin insulating layer of a cyclized perfluoro polymer called CYTOP (Asahi Glass Co., Tokyo, Japan) on SiO(2) for operation in aqueous media. The stability and sensitivity of these transistor sensors were examined in aqueous buffer media with solutions of variable pH levels after the passivation of perfluoro polymers with thicknesses ranging from 50 to 300 nm. These transistor sensors were further modified with an ultra-thin film (5 nm) functional layer for selective BSA/antiBSA detection in aqueous buffer media, demonstrating a detection capability as low as 500 nM of concentrated antiBSA. The dissociation constant from the antiBSA detection results was 2.1×10(-6)M. Thus, this study represents a significant step forward in the development of organic electronics for a disposable and versatile chemical and bio-sensing platform.  相似文献   

19.
DNA electrochemical biosensor based on thionine-graphene nanocomposite   总被引:1,自引:0,他引:1  
A novel protocol for development of DNA electrochemical biosensor based on thionine-graphene nanocomposite modified gold electrode was presented. The thionine-graphene nanocomposite layer with highly conductive property was characterized by scanning electron microscopy, transmission electron microscopy, cyclic voltammetry and electrochemical impedance spectroscopy. An amino-substituted oligonucleotide probe was covalently grafted onto the surface of the thionine-graphene nanocomposite by the cross-linker glutaraldehyde. The hybridization reaction on the modified electrode was monitored by differential pulse voltammetry analysis using an electroactive intercalator daunomycin as the indicator. Under optimum conditions, the proposed biosensor exhibited high sensitivity and low detection limit for detecting complementary oligonucleotide. The complementary oligonucleotide could be quantified in a wide range of 1.0 × 10(-12) to 1.0 × 10(-7)M with a good linearity (R(2)=0.9976) and a low detection limit of 1.26 × 10(-13)M (S/N=3). In addition, the biosensor was highly selective to discriminate one-base or two-base mismatched sequences.  相似文献   

20.
Poly(ionic liquid) (PIL) coated ordered mesoporous carbons (OMCs) were prepared by in situ polymerization of 3-ethyl-1-vinylimidazolium tetrafluoroborate ([VEIM]BF(4)) monomer on OMCs matrix. PIL on the surface of OMCs can provide sufficient binding sites to anchor the precursors of metal ion. PIL/OMCs were employed as support material for the deposition and formation of ultra-fine Pt nanoparticles, via the self-assembly between the negative Pt precursor and positively charged functional groups of PIL-functionalized OMCs. The combination of the unique properties of each component endows Pt/PIL/OMCs as a good electrode material. Compared with the Pt/OMCs nanocomposite, the Pt/PIL/OMCs modified electrode displays high electrocatalytic activity towards hydrogen peroxide (H(2)O(2)) and gives linear range from 1.0 × 10(-7) to 3.2 × 10(-3) M (R=0.999). The Pt/PIL/OMCs responds very rapidly to the changes in the level of H(2)O(2), producing steady-state signals within 4-5s. A high sensitivity of 24.43 μA mM(-1) and low detection limit of 0.08 μM was obtained at Pt/PIL/OMCs modified electrode towards the reduction of H(2)O(2). The improved activity makes Pt/PIL/OMCs nanocomposite promising for being developed as an attractive robust and new electrode material for electrochemical sensors and biosensors design.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号