首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, rapid and sensitive method based on dispersive liquid-liquid microextraction (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine opium alkaloids in urine samples. Some effective parameters on extraction were studied and optimized. Under the optimum conditions, enrichment factors and recoveries for different opiates are in the range of 63.0-104.5 and 31.5-52.2%, respectively. The calibration graphs are linear in the range of 0.50-500 μg L(-1) and limit of detections (LODs) are in the range of 0.2-10 μg L(-1). The relative standard deviations (RSDs) for 200 μg L(-1) of morphine, codeine and thebaine, 5.0 μg L(-1) of papaverine and 10.0 μg L(-1) of noscapine in diluted urine sample are in the range of 2.8-6.1% (n=7). The relative recoveries of urine samples spiked with alkaloids are 84.3-106.0%. The obtained results show that DLLME combined with HPLC-UV is a fast and simple method for the determination of opium alkaloids in urine samples.  相似文献   

2.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10-μm μBondapak phenyl column with an eluting solvent of water—methanol—1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(d-(-)-α-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 ± 6.3% (S.D.) in the concentration ranges of 0.1–20 μg per 0.2 ml of plasma with a limit of detection equivalent to 0.5 μg/ml plasma. The urine assay was validated over a concentration range of 0.025–5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 μg/ml) using a 0.1-ml urine specimen per assay.The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples.  相似文献   

3.
Two different enantioselective chiral chromatographic methods were developed and validated to investigate the disposition of the β1-receptor antagonist atenolol in blood and in brain extracellular fluid of rats (tissue dialysates). System A for the plasma samples was a one-column chromatographic system with a Chiral CBH column with an aqueous buffer as mobile phase into which cellobiose was added for selective regulation of the retention of the internal standard, (S)-metoprolol. The plasma samples were analysed after a simple extraction procedure. The limit of quantitation was 0.2 μg/ml for the atenolol enantiomers. The repeatability of the medium concentration quality control plasma sample (6.0 μg rac-atenolol/ml) was 11–18% for the enantiomers. The dynamic linear range of the plasma samples was 0.5–20 μg/ml. For system B, since atenolol is an extremely hydrophilic drug, the tissue dialysate sample required a much more sensitive system as compared to the plasma samples. A coupled column system was used for peak compression of the enantiomers in the eluate after the separation on the Chiral CBH column, hence increasing the detection sensitivity. The limit of quantification was 0.045 μg/ml for the atenolol enantiomers in artificial CSF. The repeatability of the medium concentration quality control samples (0.1 and 4.0 μg rac-atenolol/ml in artificial CSF and Hepes Ringer, respectively) was 2.8–9.3% for the two enantiomers. The dynamic linear range of the brain samples was 0.05–1.0 and 0.5–20 μg/ml in artificial CSF and Hepes Ringer, respectively. Chirality 9:329–334, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

4.
M. Henry Gault 《CMAJ》1966,94(2):61-67
A simple method is described for the assessment of renal function, without collection of urine. Phenolsulfonphthalein (PSP) is injected intravenously in a dosage of 1 mg./kg. body weight, and blood samples are taken at timed intervals. Only one venepuncture is required. The index is based on the rate of decrease in concentration of PSP in the plasma 15 to 35 minutes after injection, during which time this rate is exponential. The methodology and normal range, and the influence of dose, urine flow rate, age and body surface are defined. The extrarenal component of the PSP index and the distribution of PSP in body fluids are discussed.  相似文献   

5.
BackgroundResearch to date suggests that nickel affects not only the metabolism of vitamin B12 but also folates and thus may affect hematopoiesis processes.ObjectiveThe aim of the study was to examine the relationship of nickel (Ni) status to red blood cell (RBC) parameters and serum vitamin B12, folate and homocysteine concentrations in the course of normal pregnancy and in pregnant women with anemia.MethodsThe study included fifty-three pregnant women recruited to the study from the Lower Silesia region of Poland, 17 % of whom developed anemia. Nickel concentration was determined in urine, whole blood and food samples by atomic absorption spectrometry. At the same time as the food and urine samples were taken, blood was also collected for the determination of RBC parameters and serum vitamin B12, homocysteine and folate concentrations.ResultsThe median reported Ni intake, and the urinary and whole blood nickel contents for the studied pregnant women for the first trimester were respectively – 162.46 μg/day, 3.98 μg/L and 3.32 μg/L; for the second trimester – 110.48 μg/day, 6.86 μg/L and 1.04 μg/L; and for the third trimester – 132.20 μg/day, 3.41 μg/L and 0.70 μg/L. With regard to Ni concentration in whole blood (p = 0.0204) and in urine (p = 0.0003), the differences in the values for individual trimesters were statistically significant. The whole blood Ni level was significantly higher (9.28 vs 3.62 μg/L, p = 0.0114), while the concentration of homosysteine was significantly lower (4.09 vs 5.04 μmol/L, p = 0.0165) in pregnant women with anemia compared to those without anemia. The whole blood Ni concentration was negatively correlated with almost all RBC parameters in non-anemic pregnant women.ConclusionsNi status changes with the development of normal pregnancy, and in the case of anemia, an increase in Ni concentration in whole blood is observed. The demonstrated correlations between the Ni status in pregnant women and RBC parameters as well as serum vitamin B12 and folate concentrations suggest that nickel is associated with the methionine–folate cycle, iron homeostasis and bacterial synthesis of vitamin B12 in humans.  相似文献   

6.
A simple, accurate and sensitive high-performance liquid chromatographic method with UV detection was carried out to measure simultaneously plasma and urine concentrations of both p-aminohippuric acid and inulin. Following a simplified acid hydrolysis of the sample, the separation was carried out in 4 min using a C18 reversed-phase column with a flow-rate of 1 ml/min, and monitoring the absorbance at 280 nm. Within the investigated concentration ranges of inulin (0.1–3.2 mg/ml) and p-aminohippuric acid (0.0097–0.3 mg/ml), good linearity (r>0.99) was obtained. Within-run RSD ranged from 2.9 to 6.1% and between-run RSD ranged from 6.4 to 10%. Analytical recoveries were 101–112%, with little differences between plasma and urine samples. The detection limit was 1 μg/ml for all the analytes studied. This method might be ideal for renal function studies where a rapid and reproducible assessment of both renal glomerular filtration rate and blood flow-rate is required.  相似文献   

7.
A simple and sensitive high-performance liquid chromatograhic (HPLC) method for the determination of (+)-(S)-sotalol and (−)-(R)-sotalol in biological fluids was established. Following extraction with isopropyl alcohol from biological samples on a Sep-Pak C18 cartridge, the eluent was derivatized with 2,3,4,6-tetra-O-acetyl-β-d-glucopyranosol isothiocyanate (GITC). The diastereoisomeric derivatives are resolved by HPLC with UV detection at 225 nm. Calibration was linear from 0.022 to 4.41 μg/ml in human plasma and from 0.22 to 88.2 μg/ml in human urine for both (+)-(S)- and (−)-(R)-sotalol. The lower limit of determination was 0.022 μg/ml for plasma and 0.22 μg/ml for urine. The within-day and day-to-day coefficients of variation were less than 7.5% for each enantiomer at 0.09 and 1.8 μg/ml in plasma and at 0.44 and 4.4 μg/ml in urine. The method is also applicable to other biological specimens such as rat, mouse and rabbit plasma.  相似文献   

8.
A high-performance liquid chromatographic method with ultraviolet detection has been developed to quantify NB-506 and its active metabolite in human plasma and urine. This method is based on solid-phase extraction, thereby allowing the simultaneous measurement of the drug and metabolite with the limit of quantification of 0.01 μg/ml in plasma and 0.1 μg/ml in urine. Standard curves for the compounds were linear in the concentration ranges investigated. The range for the drug in plasma was 0.01–2.5 μg/ml, and for the metabolite 0.01–1 μg/ml. In urine, the range for both compounds was 0.1–10 μg/ml. The method was validated and applied to the assay of plasma and urinary samples from phase I studies.  相似文献   

9.
A gas chromatography-mass spectrometric (GC-MS) method was developed for the determination of 2-naphthol (2-NAP) and 1-hydroxypyrene (1-HOP) in human urine. Extraction from urine after the enzyme hydrolysis with β-glucuronidase/arylsulfatase was achieved with a liquid extraction using 5 mL of pentane. After addition of 50 μL of N-methyl-N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBDMSTFA) to prevent the loss of 2-NAP during drying, the extract was completely dried and derivatized with MTBDMSTFA for 30 min at 60 °C. The accuracies were in the range of 96-109% at a concentration of 0.5, 10 and 25 μg/L and their precisions were less than 15%. Method detection limits of 2-NAP and 1-HOP were 0.07 and 0.01 μg/L, respectively. This method was used to analyze twenty urine samples, and they were found in the concentration range <0.07-13.7 μg/L (2-NAP) and <0.01-0.88 μg/L (1-HOP). The concentrations of 2-NAP and 1-HOP were well correlated to those of naphthalene and pyrene in blood, respectively.  相似文献   

10.
A rapid, sensitive and specific normal-phase (adsorption) high-performance liquid chromatographic (HPLC) assay was developed for the determination of 1-(2-aminoethyl)-3-(2,6-dichlorophenyl)thiourea [I] in plasma and urine. The assay involves the extraction of the compound into methylene chloride from plasma or urine buffered to pH 10, and the HPLC analysis of the residue dissolved in methylene chloride—methanol—heptane (85:10:5). A 10-μm silica gel column was used with methylene chloride—methanol—heptane—ammonium hydroxide (85:10:5:0.1) as the eluting solvent. The effluent was monitored at 254 nm and quantitation was based on the peak height vs. concentration technique. The assay has a recovery of 64.5 ± 4.5% (S.D.) from plasma and 96.0 ± 6.3% (S.D.) from urine in the concentration range of 0.1–2 μg per ml and 2–40 μg per 0.1 ml of plasma and urine, respectively, with a limit of detection of 0.05–0.1 μg [I] per ml of plasma using a 1-ml specimen and 0.1 μg per ml urine using a 0.1-ml specimen, respectively. The assay was applied to the determination of plasma levels and urinary excretion of the compound [I] in dog following the oral administration of 28.8 mg of [I] · maleate per kg body weight.The HPLC assay was also used to determine the stability of [I] and for the measurement of a potential degradation product, clonidine [II] [2-(2,6-dichlorophenylamino)-2-imidazoline] in pooled human plasma stored at ?17°C, and pooled human urine stored at ?17°C and ?90°C, respectively.  相似文献   

11.
A high-performance liquid chromatographic (HPLC) method with ultraviolet (UV) absorbance was developed for the analysis of piperacillin-tazobactam (tazocillin), in plasma and urine. The detection was performed at 218 nm for tazobactam and 222 nm for piperacillin. The procedure for assay of these two compounds in plasma and of piperacillin in urine involves the addition of an internal standard (ceftazidime for tazobactam and benzylpenicillin for piperacillin) followed by a treatment of the samples with acetonitrile and chloroform. To quantify tazobactam in urine, diluted samples were analysed using a column-switching technique without internal standard. The HPLC column, LiChrosorb RP-select B, was equilibrated with an eluent mixture composed of acetonitrile-ammonium acetate (pH 5). The proposed technique is reproducible, selective, and reliable. The method has been validated, and stability tests under various conditions have been performed. Linear detector responses were observed for the calibration curve standards in the ranges 5–60 μg/ml for tazobactam, and 1–100 μg/ml for piperacillin and spans what is currently though to be the clinically relevant range for tazocillin concentrations in body fluids. The limit of quantification was 3 μg/ml for tazobactam and 0.5 μg/ml for piperacillin in plasma and urine. Extraction recoveries from plasma proved to be more than 85%. Precision, expressed as C.V., was in the range 0.4–18%.  相似文献   

12.
A new method for the analysis of 1-hydroxy-2-imidazol-1-yl-phosphonoethyl phosphoric acid (zoledronic acid) in urine and blood samples has been developed. It consists of a derivatisation of the bisphosphonate with trimethylsilyl diazomethane under multiple methylester formation. The formed derivative can, in contrast to the non-derivatised analyte, easily be separated by reversed phase liquid chromatography due to its reduced polarity. Detection is performed by electrospray tandem mass spectrometry. For calibration purposes, a deuterated internal standard has been synthesised in a three-step synthesis starting with d(4)-imidazole. For human urine, the limit of detection (LOD) is 1.2x10(-7) mol/L, limit of quantification (LOQ) is 3.75×10(-7) mol/L in the MRM mode. For human blood plasma, a LOD of 1×10(-7) mol/L and a LOQ of 2.5×10(-7) mol/L were determined. The linear dynamic range comprised 3.5 decades starting at the limit of quantification. The method was successfully applied for the analysis of spiked urine and blood plasma samples as well as samples from two osteoporosis patients.  相似文献   

13.
A simple and rapid (extractionless) high-performance liquid chromatographic method with UV detection, at 330 nm, was developed for the simultaneous determination of piroxicam and its major metabolite, 5′-hydroxypiroxicam, in human plasma and urine. Acidified plasma and alkali-treated urine samples are used and naproxen is added as internal standard. The separation is performed at 40°C on a C18 Spherisorb column with acetonitrile-0.1 M sodium acetate (33:67, v/v, pH 3.3) as mobile phase. The retention time is 2.2 min for 5′-hydroxypiroxicam, 2.6 min for piroxicam and 3.2 min for naproxen. The detection limit is 0.05 μg/ml using a 100-μl loop.  相似文献   

14.
The interaction of riboflavin with salmon sperm double-stranded DNA based on the decreasing of the oxidation signal of guanine and adenine bases was studied electrochemically with a pencil graphite electrode (PGE) using differential pulse voltammetry. The decrease in the intensity of the guanine and adenine oxidation signals after interaction with riboflavin was used as an indicator signals for the sensitive determination of riboflavin. Under the optimum conditions, a linear dependence of the guanine and adenine oxidation signals was observed for the riboflavin concentration in the range of 0.5-70 μg mL(-1) with a detection limit of 0.34 μg mL(-1) at ds-DNA modified PGE. The reproducibility and applicability of the analysis to pharmaceutical dosage forms and urine sample were also investigated. These results showed that this DNA biosensor could be used for the sensitive, rapid, simple and cost effective detection and determination of riboflavin-ds-DNA interaction. Pretreated pencil graphite electrode (PPGE) was also used for the determination of riboflavin by differential pulse adsorptive stripping voltammetry. With PPGE, a linear relationship was obtained for riboflavin over the concentration range of 0.003-0.88 μg mL(-1) with differential pulse adsorptive stripping voltammetric signal and with a detection limit of 0.076 ng mL(-1). Both determination methods were fully validated and applied for the analysis of riboflavin.  相似文献   

15.
Seven goats were given medetomidine 5 μg/kg as an iv bolus injection. Venous blood samples were taken repeatedly and urine was collected continuously via a catheter up to 7h after the injection. Medetomidine caused deep clinical sedation. Base excess, pH and PCO2 in venous blood rose after medetomidine administration. There were no significant changes in plasma concentrations of sodium, calcium, magnesium, creatinine or osmolality, whereas potassium and bicarbonate concentrations increased, and phosphate and chloride decreased. Medetomidine increased plasma glucose concentration, and in 4 of 7 goats glucose could also be detected in urine. Medetomidine did not influence urine flow rate, free water clearance, bicarbonate and phosphate excretion or pH, but renal chloride, sodium, potassium, calcium, magnesium and creatinine excretion were reduced. The results suggest that the metabolic alkalosis recorded after medetomidine administration is not caused by increased renal acid excretion.  相似文献   

16.
A high performance liquid chromatography method with ultraviolet and fluorimetric detection has been developed for the simultaneous determination of urinary creatinine (Cr), tryptophan (Trp) and three Trp-related metabolites including kynurenine (Kyn), kynurenic acid (Kyna) and 5-hydroxyindole-3-acetic acid (5-HIAA). Samples were pretreated by centrifugation after a freeze-thaw cycle to remove protein and other precipitates. Separation was achieved by an Agilent HC-C18 (2) analytical column and a gradient elution program with a constant flow rate 1mL/min at an ambient temperature. Total run time was 30 min. Cr, Kyn and Kyna were measured by a variable wavelength detector at wavelengths 258 nm, 365 nm and 344 nm respectively. Trp and 5-HIAA were measured by a fluorescence detector with an excitation wavelength of 295 nm and an emission wavelength of 340 nm. This allowed the determination of Kyn/Cr, Kyna/Cr, Trp/Cr and 5-HIAA/Cr concentration ratios in a single run on the same urine sample. Good linear responses were found with correlation coefficient (r)>0.999 for all analytes within the concentration range of physiological level. The limit of detection of the developed method was: Cr, 0.0002 g/L; Kyn, 0.1 μmol/L; Kyna, 0.04 μmol/L; Trp, 0.02 μmol/L and 5-HIAA, 0.01 μmol/L. Recoveries from spiked human urine were: Cr, 93.0-106.4%; Kyn, 97.9-106.9%; Kyna, 98.5-105.6%; Trp, 96.7-105.2% and 5-HIAA, 96.1-99.7%. CVs of repeatability and intermediate precision of all analytes were less than 5%. This method has been applied to the analysis of urine samples from normal subjects.  相似文献   

17.
This paper presents specific and sensitive high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) assays for the quantification of the novel anticancer agent eribulin in human plasma, whole blood, urine and faeces. These assays, developed to support clinical pharmacological studies with the drug, quantify eribulin concentration ranges of 0.2-100ng/mL for plasma, 0.5-100 ng/mL for whole blood and urine and 0.1-25 μg/g for faeces, using sample volumes of 500 μL or 250 μg (faeces). Samples were prepared with liquid-liquid extraction, separated on a C18 column with gradient elution and analysed with a triple quadrupole MS, in positive ion mode. A structural analogue of eribulin was used as internal standard for the quantification. The assays were linear with correlation coefficients (r(2)) of 0.99 and better, whereby the deviation from nominal concentrations ranged from -8.2 to 8.9% with CV values of maximally 14.2%. Stability assessments demonstrated that eribulin is stable at -20°C in plasma, whole blood, urine and faeces for at least 38, 4, 10.5 and 5 months, respectively. In conclusion, the validation results show that the assays are specific and accurate and can therefore adequately be applied to support clinical studies of eribulin.  相似文献   

18.
A rapid and sensitive strategy was proposed for the detection of fluoranthene (FL), which is a polycyclic aromatic hydrocarbon (PAH), in water samples. In this work, syringe solid-phase extraction (SPE) combined with solid-phase fluorescence spectrometry was used to determine FL in PAHs polluted environmental samples. The fluorescence signals were directly monitored on the membrane surface after FL was enriched by syringe SPE. Under the optimal conditions, the proposed method showed a linear relationship in the concentration range 2–50 μg/L with a correlation coefficient (R2) of 0.998, and the limit of detection was 0.143 μg/L. The recoveries varied from 93.47% to 109.81% in the actual samples, with the relative standard deviations (n = 3) ranging from 2.06% to 6.32%. According to the results, the established method can be applied in the field of rapid detection as it is fast, simple, portable, and highly sensitive, and has strong anti-interference.  相似文献   

19.
Dalbavancin is a novel second-generation lipoglycopeptide antibiotic with activity against broad range of Gram-positive pathogens. In order to determine the pharmacokinetics (PK) of dalbavancin in pediatric patients, a new High Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS) bioanalytical method has been developed for quantification of dalbavancin in plasma and in urine. The plasma method was validated for dalbavancin in the linear range from 0.5 μg/mL to 500 μg/mL using 50 μL of K(2) EDTA plasma. For dalbavancin spiked in urine, non-specific binding (NSB) of the drug to polypropylene (PP) urine collection containers was observed. The loss amounted to about 10% per transfer. After successfully establishing the collection/sampling procedure for urine by addition of Triton X-100 to the collection vessels (with a purpose of preventing NSB), the method was validated for dalbavancin in the range from 0.05 μg/mL to 50 μg/mL, using 100 μL of urine. These methods were used to quantify dalbavancin in plasma and urine of hospitalized children in a pediatric dalbavancin PK study. Eighteen percent of the total number of plasma study samples was reassayed for incurred samples reproducibility (ISR) and all the reassayed dalbavancin concentrations were within the ± 20% limits. For urine, all the collected samples were reassayed for ISR and the original dalbavancin concentration was confirmed within the ± 20% limits for 17 (94%) samples; the one remaining urine sample had its reassayed concentration confirmed within ± 25% of the original result.  相似文献   

20.
We report on the quantitative determination of acetaminophen (paracetamol; NAPAP-d(0)) in human plasma and urine by GC-MS and GC-MS/MS in the electron-capture negative-ion chemical ionization (ECNICI) mode after derivatization with pentafluorobenzyl (PFB) bromide (PFB-Br). Commercially available tetradeuterated acetaminophen (NAPAP-d(4)) was used as the internal standard. NAPAP-d(0) and NAPAP-d(4) were extracted from 100-μL aliquots of plasma and urine with 300 μL ethyl acetate (EA) by vortexing (60s). After centrifugation the EA phase was collected, the solvent was removed under a stream of nitrogen gas, and the residue was reconstituted in acetonitrile (MeCN, 100 μL). PFB-Br (10 μL, 30 vol% in MeCN) and N,N-diisopropylethylamine (10 μL) were added and the mixture was incubated for 60 min at 30 °C. Then, solvents and reagents were removed under nitrogen and the residue was taken up with 1000 μL of toluene, from which 1-μL aliquots were injected in the splitless mode. GC-MS quantification was performed by selected-ion monitoring ions due to [M-PFB](-) and [M-PFB-H](-), m/z 150 and m/z 149 for NAPAP-d(0) and m/z 154 and m/z 153 for NAPAP-d(4), respectively. GC-MS/MS quantification was performed by selected-reaction monitoring the transition m/z 150 → m/z 107 and m/z 149 → m/z 134 for NAPAP-d(0) and m/z 154 → m/z 111 and m/z 153 → m/z 138 for NAPAP-d(4). The method was validated for human plasma (range, 0-130 μM NAPAP-d(0)) and urine (range, 0-1300 μM NAPAP-d(0)). Accuracy (recovery, %) ranged between 89 and 119%, and imprecision (RSD, %) was below 19% in these matrices and ranges. A close correlation (r>0.999) was found between the concentrations measured by GC-MS and GC-MS/MS. By this method, acetaminophen can be reliably quantified in small plasma and urine sample volumes (e.g., 10 μL). The analytical performance of the method makes it especially useful in pediatrics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号