首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The applicability of reversed-phase high-performance liquid chromatography (HPLC) to the analysis of the products of recombinant insulin was studied. The influence of several mobile phases in reversed-phase and ion-pair HPLC on selectivity, resolution and sensitivity was investigated. Optimum conditions for the separation of insulin-related proteins on commercial and laboratory-made supports were established by means of three-dimensional optimizations of selectivity and resolution as a function of pH and ionic strength (μ). A mechanism for the separation of proteins with a mobile phase containing a high salt concentration and a pH near the isoelectric point of proteins is proposed. The questions of scaling up are considered. The proposed techniques allow the analysis of the main impurities and ensures a high quality of active insulin production.  相似文献   

2.
An HPLC method with two derivatizations, the first with o-phthaldehyde in order to eliminate interferences due to some primary amino acids eluting with retention times similar to those of hydroxyproline and the second with dabsyl chloride, was developed and evaluated. Calibration graph linearity, influence of agitation and temperature on the preparation of the first derivative and the influence of the detection wavelength were assessed. The analysis time is shorter in comparison with other available methods, and therefore this method is suitable for laboratories that analyse both small and large series of samples.  相似文献   

3.
A reversed-phase HPLC method for the quantification of aloesin, aloeresin a and anthraquinone (as barbaloin) in Aloe ferox Miller and aloe-related products has been developed and validated. The method utilized a C18 column with a water-methanol gradient and UV detection at 297 nm. The method validation included linearity, accuracy, precision, limit of detection, limit of quantitation, specificity and standard solution stability. The method showed good linearity (r > 0.99 for all components) and recovery (>85% for all components). The detection and quantitation limits for barbaloin were determined to be 0.02 and 0.1 ppm at signal-to-noise ratios of approximately 3:1 and 10:1, respectively.  相似文献   

4.
The objective of this research was to develop a rapid, sensitive and reliable method for the separation of phosphonodipeptide prodrugs and parent compounds to facilitate the evaluation of cell permeation using in vitro cell culture models. Separation was accomplished isocratically within 10.0 min using a C18 (150×4.6 mm I.D., 3 μm) reversed-phase column. The mobile phase consisted of 5 mM tetrahexyl ammonium (ion-pair reagent) in 0.02 M phosphate buffer pH 6.5-acetonitrile (48.5:51.5, v/v). The flow-rate was 1.1 ml/min with detection at 221 nm. The standard curves were linear (r2>0.999) over the concentration range 1–100 μM. The method was reliable and reproducible, with the limit of quantitation being 1 μM (25 ng on column).  相似文献   

5.
A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of ketoconazole in human plasma. The method entailed direct injection of the plasma sample after deproteinization using acetonitrile. The mobile phase comprised 0.05 M disodium hydrogen orthophosphate and acetonitrile (50:50, v/v) adjusted to pH 6. Analysis was run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 260 nm and an emission wavelength of 375 nm. The method is specific and sensitive with a quantification limit of approximately 60 ng/ml and a detection limit of 40 ng/ml at a signal-to-noise ratio of 3:1. Mean absolute recovery value was about 105%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 14%. The calibration curve was linear over a concentration range of 62.5–8000 ng/ml.  相似文献   

6.
A reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for detection and quantification of free maytansinoid drug in disulfide-linked conjugates between monoclonal antibodies and the maytansinoid drug DM1 (MAb-DM1). Mobile phases and gradient conditions were optimized for separation of several DM1-related free drug species from MAb-DM1 conjugates. The selectivity, linearity, and reproducibility of the method are reported. Reduction of the disulfide-linked DM1 followed by RP-HPLC allowed estimation of purity of MAb-linked DM1 as well as recovery of L-DM1. The method was also used to estimate drug per MAb ratios, which were consistent with those determined by UV spectroscopy.  相似文献   

7.
Warfarin is the most common agent used for control and prevention of venous as well as arterial thromboembolism. Although warfarin is administered as a racemic mixture of two stereoisomers (S and R), the S-form is mainly responsible for the anticoagulant effect. The anticoagulant effect of the drug is monitored by analysis of prothrombin complex (International Normalised Ratio,INR). In some cases, however, the measurements of plasma warfarin concentration are needed. Here, we present a new, rapid, sensitive and cost-effective HPLC-method for the determination of warfarin enantiomers in plasma. The chromatographic system consisted of Waters 616 gradient pump, Waters 996 photo diode array detector, Gilson 230 autoinjector and Pirkle (R,R) Whelk-O1 column (25 cmx4.6 mm I.D., 5 microm). An isocratic mobile phase of methanol/acetonitrile/water (50/10/40, v/v) with 0.1% glacial acetic acid was used. The follow rate was 1 mL/min. Data analysis was carried out with Waters Millennium32. The absorbance at 305 nm was measured with a total run-time of 15 min. Method linearity was studied by establishing regression data containing eight points over the range 0.08-10 microg/mL. In this range, warfarin showed to be linear (r2=0.9997 for S-warfarin and r2=0.9998 for R-warfarin). The limit of detection in plasma was 16 ng/mL for S-warfarin and 18 ng/mL for R-warfarin. Limit of quatitation was defined as 10xLOD. The extraction recovery was approximately 80%. Also the relation between INR and warfarin concentration was investigated. As expected, there was a low correlation between these two variables (r=0.23, y=0.3044x+0.9712). This method offers a rapid and cost-effective determination of warfarin enantiomers in human plasma.  相似文献   

8.
A reversed-phase high-performance liquid chromatographic method for the simultaneous determination of cyproterone acetate (CPA), 15 beta-hydroxycyproterone acetate (15 beta-OH-CPA) and cyproterone (CP) was reported. This method was specific, sensitive, precise, easy and rapid for determination of the serum concentrations of these steroids in patients receiving CPA. Although no peak corresponding to CP was observed for serum, peaks corresponding to CPA and 15 beta-OH-CPA were detected and well separated in all subjects undergoing long-term CPA therapy. In these patients, there seemed to be a dose-dependent relationship between the amount of CPA administered and the serum concentrations of these steroids, and the serum concentrations of CPA were either similar or low compared with those of 15 beta-OH-CPA. In conclusion, this simplified method is thought to be very valuable for studies on the pharmacokinetics of CPA and 15 beta-OH-CPA, and on the relationship between the CPA dosage and the therapeutic or side effects on adrenal and gonadal steroid production.  相似文献   

9.
A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of vitamin E especially δ-, γ- and α-tocotrienols in human plasma. The method entailed direct injection of plasma sample after deproteinization using a 3:2 mixture of acetonitrile–tetrahydrofuran. The mobile phase comprised 0.5% (v/v) of distilled water in methanol. Analyses were run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 296 nm and emission wavelength of 330 nm. This method is specific and sensitive, with a quantification limit of approximately 40, 34 and 16 ng/ml for α-, γ- and δ-tocotrienol, respectively. The mean absolute recovery values were about 98% while the within-day and between-day relative standard deviation and percent error values of the assay method were all less than 12.0% for α-, γ- and δ-tocotrienol. The calibration curve was linear over a concentration range of 40–2500, 30–4000 and 16–1000 ng/ml for α-, γ- and δ-tocotrienol, respectively. Application of the method in a bioavailability study for determination of the above compounds was also demonstrated.  相似文献   

10.
A high-performance liquid chromatographic (HPLC) procedure for lamotrigine was developed and validated. Lamotrigine (LTG) and an internal standard were extracted from plasma using liquid–liquid extraction under alkaline conditions into an organic solvent. The method was linear in the range 0.78–46.95 μmol/l, with a mean coefficient of correlation (r)≥0.99923. The limit of detection (LOD) and limit of quantification (LOQ) were 0.19 and 0.58 μmol/l, respectively. Within- and between-run precision studies demonstrated C.V.<3% at all tested concentrations. LTG median recovery was 86.14%. Antiepileptic drugs tested did not interfere with the assay. The method showed to be appropriate for monitoring LTG in plasma samples.  相似文献   

11.
A simple high-performance liquid chromatographic method was developed for the determination of ranitidine in human plasma. Prior to analysis, ranitidine and the internal standard (metoprolol) were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M potassium dihydrogenphosphate–acetonitrile (88:12, v/v) adjusted to pH 6.5. Analysis was run at a flow-rate of 1.3 ml/min and at a detection wavelength of 229 nm. The method is sensitive with a detection limit of 1 ng/ml at a signal-to-noise ratio of 3:1, while the quantification limit was set at 15 ng/ml. The calibration curve was linear over a concentration range of 15–2000 ng/ml. Mean recovery value of the extraction procedure was about 90%, while the within-day and between-day coefficients of variation and percent error values of the assay method were all less than 15%.  相似文献   

12.
A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of metformin in human plasma. The method entailed direct injection of the plasma sample after deproteination using perchloric acid. The mobile phase comprised 0.01 M potassium dihydrogen orthophosphate (pH 3.5) and acetonitrile (60:40, v/v). Analyses were run at a flow-rate of 1.0 ml/min with the detector operating at a detection wavelength of 234 nm. The method is specific and sensitive, with a quantification limit of approximately 60 ng/ml and a detection limit of 15 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery value was about 97%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The calibration curve was linear over a concentration range of 62.5–4000 ng/ml.  相似文献   

13.
Reversed-phase high-performance liquid chromatography (HPLC) on a column of Radial-Pak C18 cartridge was utilized for the purification of a variety of growth hormone (GH) proteins from mammalian, avian, amphibian and fish pituitary glands. Recovery of GH from pituitary glands of up to 0.43% of total protein was obtained with a high degree of homogeneity as revealed by sodium dodecyl sulphate polyacrylamide gel electrophoresis. The HPLC-purified GHs show reactions of identity or near identity by immuno-diffusion studies on agar gel. This method offers a convenient and rapid purification of vertebrate GH on an analytical or preparative scale.  相似文献   

14.
Capillary reversed-phase high-performance liquid chromatography (RP-HPLC) was used to determine acetylmethylprednisolone (A-MP) that had been administered to feline spinal cord tissue. The method used a 300 mm × 0.32 mm I.D. packed capillary octadecylsilyl (ODS) column and an isocratic mobile phase of 40 mM triethylamine formate (TEAF, pH 3.2)-acetonitrile (50:50, v:v). The chromatographic behavior of A-MP was evaluated with respect to peak-area and peak-height by varying the A-MP concentration (12–190 μM) with a fixed injection volume (1 μl), and by varying the injection volume (1–10 μl) with a fixed concentration (12 μM) of A-MP. The limit of detection (signal-to-noise ratio, 3:1) was 250 pg (600 fmol) of synthetic A-MP. Various amounts of A-MP directly spiked into feline spinal cord segments were solvent extracted, separated, and plotted against peak-area (r2 = 1.00). Background tissue without A-MP gives minimal (<1%) interference at 243 nm. The method also detects exogenous A-MP that was administered into feline spinal cord via an intrathecal injection. Furthermore, the presence of A-MP was confirmed via its molecular ion and corresponding product ions that were obtained by fast-atom bombardment tandem mass spectrometry (FAB-MS-MS).  相似文献   

15.
A simple high-performance liquid chromatographic method for the determination of endogenous phosphatidylinositol 4-phosphate (PIP) and phosphatidylinositol 4,5-bisphosphate (PIP2) in brain has been developed. PIP and PIP2 were derivatized with 9-anthryldiazomethane to yield (9-anthryl)PIP and di(9-anthryl)-PIP2. The derivatives were separated on a reversed-phase column using isocratic elution and detected with a uv detector. The detection limits of PIP and PIP2 were 0.25 micrograms. The method with uv detection was sufficiently sensitive to measure the concentrations of PIP and PIP2 in rat brain. The levels of PIP and PIP2 were increased in developing rat brain and were decreased after 10 min of ischemia.  相似文献   

16.
NMN adenylyltransferase (NAD pyrophosphorylase; NMNAT) reversibly catalyzes the synthesis of NAD from ATP and NMN. In this paper, we describe a rapid and sensitive high-performance liquid chromatographic assay for NMNAT, which uses a 20-mm-long C18 reversed-phase (RP) column. The activity was measured by separating in less than 3 min the substrates (NMN and ATP) from the product (NAD) with 0.1 M potassium phosphate, pH 6.0, at a 2 ml/min flow-rate and 22°C. NAD was directly quantitated from its ultraviolet absorbance. Amounts of NAD as small as 25 pmol could be measured. The activity value closely agreed with that determined by the spectrophotometric assay. This method was successfully applied to the determination of NMNAT activity in human placental and bull testis extracts, as well as in rat pheochromocytoma (PC12) cells.  相似文献   

17.
An assay for thymidine substitution by iododeoxyuridine (IdUrd) using reversed-phase high-performance liquid chromatography (HPLC) has been developed. Three principal steps in this procedure are: extraction of DNA from cell or tissues, hydrolysis of DNA into deoxynucleosides and separation using HPLC. Approximately 1 microgram of DNA was recovered from 10(5) cells by phenol extraction, and subjected to hydrolysis into deoxynucleosides which required a three-stage DNA digestion using enzymes DNAse I. phosphodiesterase I and alkaline phosphatase. The deoxynucleosides were separated on the Microsorb C18 column with isocratic elution; 90-100% of the DNA was recovered as deoxynucleosides on the column. The method was used to determine quantitatively the percent IdUrd substitution of thymidine in Chinese hamster lung cells in vitro and BA1112 rhabdomyosarcoma in WAG/Rij rats perfused with IdUrd. It was possible to determine the thymidine substitution by IdUrd as small as 1% using a few micrograms of DNA. The close correspondence between the percent substitutions determined by HPLC and those determined by radioactive assay using [125I]-labelled IdUrd, confirmed the accuracy of our HPLC method. The HPLC analysis is especially suitable for the determination of percent IdUrd substitution of thymidine in tissue biopsies from animals used in in vivo experiments or humans undergoing radiation treatment.  相似文献   

18.
A new sensitive high-performance liquid chromatographic (HPLC) method with fluorescence detection was developed for the determination of 2-phenylethylamine (PEA) in human urine. The analytical procedure involved a simple extraction of the analyte from urine, followed by precolumn derivatisation of the sample with o-phthalaldehyde. The HPLC separation was performed under isocratic conditions using an Erbasil S C18 (250 × 4.0 mm I.D., particle size 3 μm) reversed-phase column. The limit of quantification was 0.5 ng of PEA/ml of urine. The method showed good linearity, accuracy and precision data in the concentration range 0.5–200 ng/ml of urine. The method was successfully applied to the determination of PEA urinary excretion in Parkinsonian patients after oral administration of the monoamine oxidase B (MAO-B) inhibitor, selegiline.  相似文献   

19.
A simple, rapid, specific and sensitive high-performance liquid chromatography method has been developed for quantitation of 5-fluorouracil (5-FU) in human plasma. The method involves deproteinization of a small sample volume of plasma (150 μl) followed by HPLC on a cation-exchange resin column, Aminex HPX-87H (300×7.8 mm I.D.), preceded by a similar guard cartridge with UV detection at 265 nm. This method allows a good separation of 5-FU with a retention time of 24 min and a detection limit at 25 ng/ml. The calibration curve was linear from 25 to 2000 ng/ml. The coefficient of variation was ≤4.4% for within-day reproducibility and ≤9.5% for day-to-day reproducibility.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号