首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The bioreactor volume delineating the selection of primary clarification technology is not always easily defined. Development of a commercial scale process for the manufacture of therapeutic proteins requires scale‐up from a few liters to thousands of liters. While the separation techniques used for protein purification are largely conserved across scales, the separation techniques for primary cell culture clarification vary with scale. Process models were developed to compare monoclonal antibody production costs using two cell culture clarification technologies. One process model was created for cell culture clarification by disc stack centrifugation with depth filtration. A second process model was created for clarification by multi‐stage depth filtration. Analyses were performed to examine the influence of bioreactor volume, product titer, depth filter capacity, and facility utilization on overall operating costs. At bioreactor volumes <1,000 L, clarification using multi‐stage depth filtration offers cost savings compared to clarification using centrifugation. For bioreactor volumes >5,000 L, clarification using centrifugation followed by depth filtration offers significant cost savings. For bioreactor volumes of ~2,000 L, clarification costs are similar between depth filtration and centrifugation. At this scale, factors including facility utilization, available capital, ease of process development, implementation timelines, and process performance characterization play an important role in clarification technology selection. In the case study presented, a multi‐product facility selected multi‐stage depth filtration for cell culture clarification at the 500 and 2,000 L scales of operation. Facility implementation timelines, process development activities, equipment commissioning and validation, scale‐up effects, and process robustness are examined. © 2013 The Authors. American Institute of Chemical Engineers Biotechnol. Prog., 29:1239–1245, 2013  相似文献   

2.
Escherichia coli is frequently used as a microbial host to express recombinant proteins but it lacks the ability to secrete proteins into medium. One option for protein release is to use high‐pressure homogenization followed by a centrifugation step to remove cell debris. While this does not give selective release of proteins in the periplasmic space, it does provide a robust process. An ultra scale‐down (USD) approach based on focused acoustics is described to study rec E. coli cell disruption by high‐pressure homogenization for recovery of an antibody fragment (Fab′) and the impact of fermentation harvest time. This approach is followed by microwell‐based USD centrifugation to study the removal of the resultant cell debris. Successful verification of this USD approach is achieved using pilot scale high‐pressure homogenization and pilot scale, continuous flow, disc stack centrifugation comparing performance parameters such as the fraction of Fab′ release, cell debris size distribution and the carryover of cell debris fine particles in the supernatant. The integration of fermentation and primary recovery stages is examined using USD monitoring of different phases of cell growth. Increasing susceptibility of the cells to disruption is observed with time following induction. For a given recovery process this results in a higher fraction of product release and a greater proportion of fine cell debris particles that are difficult to remove by centrifugation. Such observations are confirmed at pilot scale. Biotechnol. Bioeng. 2013 9999:XX–XX. © 2013 Wiley Periodicals, Inc. Biotechnol. Bioeng. 2013; 110: 2150–2160. © 2013 Wiley Periodicals, Inc.  相似文献   

3.
Fusion proteins offer the prospect of new therapeutic products with multiple functions. The primary recovery is investigated of a fusion protein consisting of modified E2 protein from hepatitis C virus fused to human IgG1 Fc and expressed in a Chinese hamster ovary (CHO) cell line. Fusion protein products inevitably pose increased challenge in preparation and purification. Of particular concerns are: (i) the impact of shear stress on product integrity and (ii) the presence of product‐related contaminants which could prove challenging to remove during the high resolution purification steps. This paper addresses the use of microwell‐based ultra scale‐down (USD) methods to develop a bioprocess strategy focused on the integration of cell culture and cell removal operations and where the focus is on the use of operations which impart low shear stress levels even when applied at eventual manufacturing scale. An USD shear device was used to demonstrate that cells exposed to high process stresses such as those that occur in the feed zone of a continuous non‐hermetic centrifuge resulted in the reduction of the fusion protein and also the release of glycosylated intracellular variants. In addition, extended cell culture resulted in release of such variants. USD mimics of low shear stress, hydrohermetic feed zone centrifugation and of depth filtration were used to demonstrate little to no release during recovery of these variants with both results verified at pilot scale. Furthermore, the USD studies were used to predict removal of contaminants such as lipids, nucleic acids, and cell debris with, for example, depth filtration delivering greater removal than for centrifugation but a small (~10%) decrease in yield of the fusion protein. These USD observations of product recovery and carryover of contaminants were also confirmed at pilot scale as was also the capacity or throughput achievable for continuous centrifugation or for depth filtration. The advantages are discussed of operating a lower yield cell culture and a low shear stress recovery process in return for a considerably less challenging purification demand. Biotechnol. Bioeng. 2013; 110: 1973–1983. © 2013 Wiley Periodicals, Inc.  相似文献   

4.
Recovery of therapeutic protein from high cell density yeast fermentations at commercial scale is a challenging task. In this study, we investigate and compare three different harvest approaches, namely centrifugation followed by depth filtration, centrifugation followed by filter-aid enhanced depth filtration, and microfiltration. This is achieved by presenting a case study involving recovery of a therapeutic protein from Pichia pastoris fermentation broth. The focus of this study is on performance of the depth filtration and the microfiltration steps. The experimental data has been fitted to the conventional models for cake filtration to evaluate specific cake resistance and cake compressibility. In the case of microfiltration, the experimental data agrees well with flux predicted by shear induced diffusion model. It is shown that, under optimal conditions, all three options can deliver the desired product recovery ( >80%), harvest time ( <15 h including sequential concentration/diafiltration step), and clarification ( <6 NTU). However, the three options differ in terms of process development time required, capital cost, consumable cost, ease of scale-ability and process robustness. It is recommended that these be kept under consideration when making a final decision on a harvesting approach.  相似文献   

5.
This article presents an application of artificial neural network (ANN) modelling towards prediction of depth filter loading capacity for clarification of a monoclonal antibody (mAb) product during commercial manufacturing. The effect of operating parameters on filter loading capacity was evaluated based on the analysis of change in the differential pressure (DP) as a function of time. The proposed ANN model uses inlet stream properties (feed turbidity, feed cell count, feed cell viability), flux, and time to predict the corresponding DP. The ANN contained a single output layer with ten neurons in hidden layer and employed a sigmoidal activation function. This network was trained with 174 training points, 37 validation points, and 37 test points. Further, a pressure cut‐off of 1.1 bar was used for sizing the filter area required under each operating condition. The modelling results showed that there was excellent agreement between the predicted and experimental data with a regression coefficient (R2) of 0.98. The developed ANN model was used for performing variable depth filter sizing for different clarification lots. Monte‐Carlo simulation was performed to estimate the cost savings by using different filter areas for different clarification lots rather than using the same filter area. A 10% saving in cost of goods was obtained for this operation. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:1436–1443, 2016  相似文献   

6.
Ultra‐scale down (USD) methodology developed by University College London for cell broth clarification with industrial centrifuges was applied to two common cell lines (NS0 and GS‐CHO) expressing various therapeutic monoclonal antibodies. A number of centrifuges at various scales were used with shear devices operating either by high speed rotation or flow‐through narrow channels. The USD methodology was found effective in accounting for both gravitational and shear effects on clarification performance with three continuous centrifuges at pilot and manufacturing scales. Different shear responses were observed with the two different cell lines and even with the same cell line expressing different products. Separate particle size analysis of the treated broths seems consistent with the shear results. Filterability of the centrifuged solutions was also evaluated to assess the utility of the USD approach for this part of the clarification operation. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2009  相似文献   

7.
In the production of biopharmaceuticals disk‐stack centrifugation is widely used as a harvest step for the removal of cells and cellular debris. Depth filters followed by sterile filters are often then employed to remove residual solids remaining in the centrate. Process development of centrifugation is usually conducted at pilot‐scale so as to mimic the commercial scale equipment but this method requires large quantities of cell culture and significant levels of effort for successful characterization. A scale‐down approach based upon the use of a shear device and a bench‐top centrifuge has been extended in this work towards a preparative methodology that successfully predicts the performance of the continuous centrifuge and polishing filters. The use of this methodology allows the effects of cell culture conditions and large‐scale centrifugal process parameters on subsequent filtration performance to be assessed at an early stage of process development where material availability is limited. Biotechnol. Bioeng. 2016;113: 1934–1941. © 2016 The Authors. Biotechnology and Bioengineering Published by Wiley Periodicals, Inc.  相似文献   

8.
This article describes how a combination of an ultra scale‐down (USD) shear device feeding a microwell centrifugation plate may be used to provide a prediction of how mammalian cell broth will clarify at scale. In particular a method is described that is inherently adaptable to a robotic platform and may be used to predict how the flow rate and capacity (equivalent settling area) of a centrifuge and the choice of feed zone configuration may affect the solids carry over in the supernatant. This is an important consideration as the extent of solids carry over will determine the required size and lifetime of a subsequent filtration stage or the passage of fine particulates and colloidal material affecting the performance and lifetime of chromatography stages. The extent of solids removal observed in individual wells of a microwell plate during centrifugation is shown to correlate with the vertical and horizontal location of the well on the plate. Geometric adjustments to the evaluation of the equivalent settling area of individual wells (ΣM) results in an improved prediction of solids removal as a function of centrifuge capacity. The USD centrifuge settling characteristics need to be as for a range of equivalent flow rates as may be experienced at an industrial scale for a machine of different shear characteristics in the entry feed zone. This was shown to be achievable with two microwell‐plate based measurements and the use of varying fill volumes in the microwells to allow the rapid study of a fivefold range of equivalent flow rates (i.e., at full scale for a particular industrial centrifuge) and the effect of a range of feed configurations. The microwell based USD method was used to examine the recovery of CHO‐S cells, prepared in a 5 L reactor, at different points of growth and for different levels of exposure to shear post reactor. The combination of particle size distribution measurements of the cells before and after shear and the effect of shear on the solids remaining after centrifugation rate provide insight into the state of the cells throughout the fermentation and the ease with which they and accumulated debris may be removed by continuous centrifugation. Hence bioprocess data are more readily available to help better integrate cell culture and cell removal stages and resolve key bioprocess design issues such as choice of time of harvesting and the impact on product yield and contaminant carry over. Operation at microwell scale allows data acquisition and bioprocess understanding over a wide range of operating conditions that might not normally be achieved during bioprocess development. Biotechnol. Bioeng. 2009; 104: 321–331 © 2009 Wiley Periodicals, Inc.  相似文献   

9.
The physical and biological conditions of the host cell obtained at the end of fermentation influences subsequent downstream processing unit operations. The ability to monitor these characteristics is central to the improvement of biopharmaceutical manufacture. In this study, we have used a combination of techniques such as adaptive focus acoustics (AFA) and ultra scale-down (USD) centrifugation that utilize milliliter quantities of sample to obtain an insight into the interaction between cells from the upstream process and initial downstream unit operations. This is achieved primarily through an assessment of cell strength and its impact on large-scale disc stack centrifugation performance, measuring critical attributes such as viscosity and particle size distribution. An Escherichia coli fed-batch fermentation expressing antibody fragments in the periplasm was used as a model system representative of current manufacturing challenges. The weakening of cell strength during cultivation time, detected through increased micronization and viscosity, resulted in a 2.6-fold increase in product release rates from the cell (as measured by AFA) and approximately fourfold decrease in clarification performance (as measured by USD centrifugation). The information obtained allows for informed harvest point decisions accounting for both product leakages during fermentation and potential losses during primary recovery. The clarification performance results were verified at pilot scale. The use of these technologies forms a route to the process understanding needed to tailor the host cell and upstream process to the product and downstream process, critical to the implementation of quality-by-design principles.  相似文献   

10.
Optimal bioreactor harvest time is typically determined based on maximizing product titer without compromising product quality. We suggest that ease of downstream purification should also be considered during harvest. In this view, we studied the effect of antiapoptosis genes on downstream performance. Our hypothesis was that more robust cells would exhibit less cell lysis and thus generate lower levels of cell debris and host‐cell contaminants. We focused on the clarification unit operation, measuring postclarification turbidity and host‐cell protein (HCP) concentration as a function of bioreactor harvest time/cell viability. In order to mimic primary clarification using disk‐stack centrifugation, a scale‐down model consisting of a rotating disk (to simulate shear in the inlet feed zone of the centrifuge) and a swinging‐bucket lab centrifuge was used. Our data suggest that in the absence of shear during primary clarification (typical of depth filters), a 20–50% reduction in HCP levels and 50–65% lower postcentrifugation turbidity was observed for cells with antiapoptosis genes compared to control cells. However, on exposing the cells to shear levels typical in a disk‐stack centrifuge, the reduction in HCP was 10–15% while no difference in postcentrifugation turbidity was observed. The maximum benefit of antiapoptosis genes is, therefore, realized using clarification options that involve low shear, <1 × 106 W/m3 and minimal damage to the cells. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 30:100–107, 2014  相似文献   

11.
Two bacterial strains used for industrial production of 2‐keto‐L‐gulonic acid (2‐KLG), Ketogulonigenium vulgare 2 and Bacillus thuringiensis 1514, were loaded onto the spacecraft Shenzhou VII and exposed to space conditions for 68 h in an attempt to increase their fermentation productivities of 2‐KLG. An optimal combination of mutants B. thuringiensis 320 and K. vulgare 2194 (KB2194‐320) was identified by systematically screening the pH and 2‐KLG production of 16 000 colonies. Compared with the coculture of parent strains, the conversion rate of L‐sorbose to 2‐KLG by KB2194‐320 in shake flask fermentation was increased significantly from 82·7% to 95·0%. Furthermore, a conversion rate of 94·5% and 2‐KLG productivity of 1·88 g l?1 h?1 were achieved with KB2194‐320 in industrial‐scale fermentation (260 m3 fermentor). An observed increase in cell number of K2194 (increased by 47·8%) during the exponential phase and decrease in 2‐KLG reductase activity (decreased by 46·0%) were assumed to explain the enhanced 2‐KLG production. The results suggested that the mutants KB2194‐320 could be ideal substitutes for the currently employed strains in the 2‐KLG fermentation process and demonstrated the feasibility of using spaceflight to breed high‐yielding 2‐KLG‐producing strains for vitamin C production.

Significance and Impact of the Study

KB2194‐320, a combination of two bacterial strains bred by spaceflight mutation, exhibited significantly improved 2‐KLG productivity and hence could potentially increase the efficiency and reduce the cost of vitamin C production by the two‐step fermentation process. In addition, a new pH indicator method was applied for rational screening of K2, which dramatically improved the efficiency of screening.  相似文献   

12.
High cell density, high product titer mammalian cell culture is the new paradigm for production of recombinant proteins. While the typical motivation is to get a high product titer, additional undesirable outcomes often include an increase in percentage solids in the cell culture fluid (cellular debris and sub-micron colloids), thereby offering new challenges to downstream processing. This article focuses on scouting and comparison of different approaches used for clarification of cell culture fluid. The approaches include centrifugation followed by depth filtration, direct depth filtration without centrifugation and feed pretreatment with use of specially designed density gradient filtration to improve efficiency of clarification and removal of process contaminants from feed stream. The work also evaluates impact of three different pretreatment approaches, namely pH adjustment to acidic condition, metal cation (calcium phosphate) flocculation, and polycationic polymer flocculation (using polymer-I and polymer-II). The results obtained indicate that the use of pretreatment significantly improves the clarification efficiency of depth filtration. Pretreatment options like polycationic polymer-I based flocculation resulted in a >5 fold reduction in filter area requirement as well as >6 fold reduction in HCDNA while retaining acceptable recovery of the IgG (>98%). Thus, pretreatment offers a significant reduction in the depth filtration footprint (~5–6 fold decrease in filter area requirement). However, one must take into consideration the process development time required, capital cost, consumable cost, cost of the pretreatment chemical, cost of testing to demonstrate clearance of treatment agent, ease of scale-ability, and process robustness when finalizing the optimal clarification approach.  相似文献   

13.
Increases in mammalian cell culture titres and densities have placed significant demands on primary recovery operation performance. This article presents a methodology which aims to screen rapidly and evaluate primary recovery technologies for their scope for technically feasible and cost‐effective operation in the context of high cell density mammalian cell cultures. It was applied to assess the performance of current (centrifugation and depth filtration options) and alternative (tangential flow filtration (TFF)) primary recovery strategies. Cell culture test materials (CCTM) were generated to simulate the most demanding cell culture conditions selected as a screening challenge for the technologies. The performance of these technology options was assessed using lab scale and ultra scale‐down (USD) mimics requiring 25–110mL volumes for centrifugation and depth filtration and TFF screening experiments respectively. A centrifugation and depth filtration combination as well as both of the alternative technologies met the performance selection criteria. A detailed process economics evaluation was carried out at three scales of manufacturing (2,000L, 10,000L, 20,000L), where alternative primary recovery options were shown to potentially provide a more cost‐effective primary recovery process in the future. This assessment process and the study results can aid technology selection to identify the most effective option for a specific scenario.  相似文献   

14.
During centrifugation operation, the major challenge in the recovery of extracellular proteins is the removal of the maximum liquid entrapped within the spaces between the settled solids–dewatering level. The ability of the scroll decanter centrifuge (SDC) to process continuously large amounts of feed material with high concentration of solids without the need for resuspension of feeds, and also to achieve relatively high dewatering, could be of great benefit for future use in the biopharmaceutical industry. However, for reliable prediction of dewatering in such a centrifuge, tests using the same kind of equipment at pilot‐scale are required, which are time consuming and costly. To alleviate the need of pilot‐scale trials, a novel USD device, with reduced amounts of feed (2 mL) and to be used in the laboratory, was developed to predict the dewatering levels of a SDC. To verify USD device, dewatering levels achieved were plotted against equivalent compression (Gtcomp) and decanting (Gtdec) times, obtained from scroll rates and feed flow rates operated at pilot‐scale, respectively. The USD device was able to successfully match dewatering trends of the pilot‐scale as a function of both Gtcomp and Gtdec, particularly for high cell density feeds, hence accounting for all key variables that influenced dewatering in a SDC. In addition, it accurately mimicked the maximum dewatering performance of the pilot‐scale equipment. Therefore the USD device has the potential to be a useful tool at early stages of process development to gather performance data in the laboratory thus minimizing lengthy and costly runs with pilot‐scale SDC. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 29:1494–1502, 2013  相似文献   

15.
Tools that allow cost‐effective screening of the susceptibility of cell lines to operating conditions which may apply during full scale processing are central to the rapid development of robust processes for cell‐based therapies. In this paper, an ultra scale‐down (USD) device has been developed for the characterization of the response of a human cell line to membrane‐based processing, using just a small quantity of cells that is often all that is available at the early discovery stage. The cell line used to develop the measurements was a clinically relevant human fibroblast cell line. The impact was evaluated by cell damage on completion of membrane processing as assessed by trypan blue exclusion and release of intracellular lactate dehydrogenase (LDH). Similar insight was gained from both methods and this allowed the extension of the use of the LDH measurements to examine cell damage as it occurs during processing by a combination of LDH appearance in the permeate and mass balancing of the overall operation. Transmission of LDH was investigated with time of operation and for the two disc speeds investigated (6,000 and 10,000 rpm or ? max ≈ 1.9 and 13.5 W mL?1, respectively). As expected, increased energy dissipation rate led to increased transmission as well as significant increases in rate and extent of cell damage. The method developed can be used to test the impact of varying operating conditions and cell lines on cell damage and morphological changes. Biotechnol. Bioeng. 2017;114: 1241–1251. © 2017 The Authors. Biotechnology and Bioengineering Published by Wiley Periodicals, Inc.
  相似文献   

16.
The high-cell-density fermentation of Candida rugosa lipase in the constitutive Pichia pastoris expression system was scaled up from 5 to 800 l in series by optimizing the fermentation conditions at both lab scale and pilot scale. The exponential feeding combined with pH-stat strategy succeeded in small scale studies, while a two-stage fermentation strategy, which shifted at 48 h by fine tuning the culture temperature and pH, was assessed effective in pilot-scale fermentation. The two-stage strategy made an excellent balance between the expression of heterogeneous protein and the growth of host cells, controlling the fermentation at a relatively low cell growth rate for the constitutive yeast expression system to accumulate high-level product. A stable lipase activity of approximately 14,000 IU ml−1 and a cell wet weight of ca. 500 g l−1 at the 800-l scale were obtained. The efficient and convenient techniques suggested in this study might facilitate further scale-up for industrial lipase production.  相似文献   

17.
Pichia pastoris is becoming a desirable host in the biopharmaceutical industry for therapeutics production. It grows on methanol to high cell densities ≥100 g DCW/L and secretes foreign proteins at high titers. However, the culture conditions to reach high cell densities pose a challenge to the processability by primary recovery operations, in particular centrifugation, used for cell removal. This work aims to assess the impact of recombinant P. pastoris strain selection on centrifugal dewatering. Normally, the choice of P. pastoris recombinant strain is based on best target protein expression levels; however, it is unknown whether the choice of strain will have an impact on performance of centrifugation operation. To achieve this aim, a previously developed laboratory ultra‐scale down (USD) methodology that successfully predicted centrifugal dewatering of pilot‐scale disk‐type machines, was used in this work. Two recombinant P. pastoris strains, namely a X‐33 and a glycoengineered Pichia strain, were used to perform fermentations secreting different products. The resulting harvested fermentation culture properties were analyzed and the dewatering performances of a pilot‐ and a large‐scale disk‐type centrifuge were evaluated using the USD methodology. The choice of P. pastoris strain was found to have a considerable impact on dewatering performance, with P. pastoris X‐33 strain reaching better dewatering levels than the glycoengineered strain. The USD method proved to be a useful tool to determine optimal conditions under which the large scale centrifuge needed to be operated, reducing the need for repeated pilot‐scale runs during early stages of process development for therapeutic products. © 2012 American Institute of Chemical Engineers Biotechnol. Prog., 28: 1029–1036, 2012  相似文献   

18.
A single-stage clarification was developed using a single-use chromatographic clarification device (CCD) to recover a recombinant protein from Chinese Hamster Ovary (CHO) harvest cell culture fluid (HCCF). Clarification of a CHO HCCF is a complex and costly process, involving multiple stages of centrifugation and/or depth filtration to remove cells and debris and to reduce process-related impurities such as host cell protein (HCP), nucleic acids, and lipids. When using depth filtration, the filter train consists of multiple filters of varying ratios, layers, pore sizes, and adsorptive properties. The depth filters, in combination with a 0.2-micron membrane filter, clarify the HCCF based on size-exclusion, adsorptive, and charge-based mechanisms, and provide robust bioburden control. Each stage of the clarification process requires time, labor, and utilities, with product loss at each step. Here, use of the 3M™ Harvest RC Chromatographic Clarifier, a single-stage CCD, is identified as an alternative strategy to a three-stage filtration train. The CCD results in less overall filter area, less volume for flushing, and higher yield. Using bioprocess cost modeling, the single-stage clarification process was compared to a three-stage filtration process. By compressing the CHO HCCF clarification to a single chromatographic stage, the overall cost of the clarification process was reduced by 17%–30%, depending on bioreactor scale. The main drivers for the cost reduction were reduced total filtration area, labor, time, and utilities. The benefits of the single-stage harvest process extended throughout the downstream process, resulting in a 25% relative increase in cumulative yield with comparable impurity clearance.  相似文献   

19.
The physiological response of erythromycin fermentation scale-up from 50 L to 132 m3 scale was investigated. A relatively high oxygen uptake rate (OUR) in early phase of fermentation was beneficial for erythromycin biosynthesis. Correspondingly, the maximal consistency coefficient (K) reflecting non-Newtonian fluid characteristics in 50 L and 132 m3 fermenter also appeared in same phase. Fluid dynamics in different scale bioreactor was further investigated by real-time computational fluid dynamics modeling. The results of simulation showed that the impeller combination in 50 L fermenter could provide more modest flow field environment compared with that in 132 m3 fermenter. The decrease of oxygen transfer rate (OTR) in 132 m3 fermenter was the main cause for impairing cell physiological metabolism and erythromycin biosynthesis. These results were helpful for understanding the relationship between hydrodynamic environment and physiological response of cells in bioreactor during the scale-up of fermentation process.  相似文献   

20.
The recovery of intracellular recombinant proteins produced in microbial systems typically requires physical, chemical or thermal treatment of the cells post-harvest to release the product into the broth, followed by removal of the cell debris using centrifugation or tangential flow filtration. Often a precipitation or flocculation step is introduced to facilitate the liquid-solid separation. Due to the complex nature of the cell materials and the unit operations, it is difficult to obtain data at laboratory scale that closely reflect the performance of these operations on larger scales (pilot or manufacturing). This study uses a predictive scale-down model that enables rapid optimization of the operating conditions for a flocculation followed with a centrifugation step using only small volumes (20 mL) of a high solids ( approximately 20% w/w) E. coli heat extract. Results obtained show that, with proper theoretical and experimental consideration to account for high cell density, conditions could be found that improve the beneficial interaction between flocculation and centrifugation. These experiments suggested that adding a higher level of a cationic polymer could substantially increase the strength of the flocculated particles produced, thereby enhancing overall clarification performance in a large scale centrifuge. This was subsequently validated at pilot scale.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号