首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Cortisol radioimmunoassays (RIA's) utilizing highly specific antisera combined with a simple ethanol protein precipitation procedure (ETOH-PPT) are widely utilized to measure cortisol in human plasma. This same type of RIA has been assumed specific for measurement of cortisol in the plasma of several different species of experimental animals. In order to test this assumption as applied to fetal ovine plasma, we compared an ETOH-PPT cortisol RIA with another rapid cortisol assay which utilizes a dichloromethane extraction (DM-E) step. The DM-E assay in turn was compared with a chromatographic assay previously shown to be highly specific for measurement of fetal plasma cortisol in this species. Fetal ovine plasma cortisol concentrations determined by the DM-E method were nearly identical to the concentrations obtained by the specific chromatographic RIA procedure. On the other hand, the ETOH-PPT RIA grossly overestimated cortisol concentrations when compared with the DM-E RIA. While the rapid DM-E RIA appears to be suitable for use in fetal ovine plasma, the widely used ETOH-PPT RIA yields spuriously high and unpredictable values and must be considered unreliable. These comparisons demonstrate the need for careful reassessment of steroid assays prior to their application in experimental animals even though they have been previously documented as specific in human plasma.  相似文献   

2.
A simple, sensitive, specific and reproducible method for the determination of corticosterone concentrations in rat serum using high-performance liquid chromatography (HPLC) with fluorimetric detection is described. Corticosterone is detectable down to 0.1 ng injected onto the HPLC column. Cortisol is used as an internal standard. Ethyl acetate was used for both initial serum corticosteroid extraction and the subsequent fluorophore extraction after sulfuric acid hydrolysis; thus sulfuric acid does not enter the HPLC system. The resultant fluorophores for both corticosterone and cortisol are stable for at least two weeks at ambient temperature not requiring storage at −20°C. The procedure is highly suitable for use with HPLC systems utilising automatic sample injectors. The method is specific for corticosterone; dexamethasone, cortisone and gonadal steroids are not detectable and do not interfere in this assay.  相似文献   

3.
Hair may be a useful matrix to detect cumulative cortisol concentrations in studies of animal welfare and chronic stress. The aim of this study was to validate a protocol for cortisol detection in hair from dairy cattle by enzyme immunoassay (EIA). Seventeen adult Holstein–Friesian dairy cows were used during the milking period. Hair cortisol concentration was assessed in 25-day-old hair samples taken from the frontal region of the head, analysing black and white coloured hair separately. Concentrations of cortisol metabolites were determined in faeces collected twice a week during the same period of time. There was a high correlation between cortisol values in faeces and cortisol in white colour hair samples but such correlation was not significant with the black colour hair samples. The intra- and inter-assay coefficients of variation were 4.9% and 10.6%, respectively. The linearity showed R2=0.98 and mean percentage error of −10.8±1.55%. The extraction efficiency was 89.0±23.52% and the parallelism test showed similar slopes. Cortisol detection in hair by using EIA seems to be a valid method to represent long-term circulating cortisol levels in dairy cattle.  相似文献   

4.
Cortisol was isolated from human urine using kieselguhr (Extrelut)-filled columns. After use, Extrelut was cleaned-up once with distilled water and twice with ethanol. Before re-use, the cleaned-up kieselguhr was dried for 24 h by a warm air stream. The comparison of cortisol recovery from human urine and HPLC chromatograms of urinary extracts show that Extrelut can be repeatedly used for liquid–liquid extraction of urinary cortisol.  相似文献   

5.
Steroidal pathophysiology of a malignant, ACTH-producing pancreas tumor was investigated via HPLC-RIA determinations of intratissular concentrations of eleven main steroid hormones. The tumor specimen underwent extraction procedure with ethyl acetate and the extract was purified on a C18 minicolumn. Steroids were isolated by HPLC (C18-silica reversed phase stationary phase and methanol-water eluent system) and quantified by specific RIAs. Cortisol content of the tumor specimen was 15,700 pmol/g, the further steroid hormones were found in much lower concentrations (< 1.5-28 pmol/g). The extremely high cortisol concentration in the tissue witnesses the synthesis of the main glucocorticoid steroid in the ACTH-producing pancreas tumor and suggests a stimulating paracrine effect of ACTH on cortisol production. The present data verify that the determination of intratissular steroid concentrations by HPLC-RIA methods may identify even the most peculiar hormone sources and the hormone profiles facilitate studying pathophysiology of ectopic endocrine tumors.  相似文献   

6.
A sensitive and specific high-performance liquid chromatographic (HPLC) method for the determination of cortisol in only 200 microliters of serum is described. Cortisol and two internal standards, 19-nortestosterone (IS1) and 6 alpha-methylprednisolone (IS2) are extracted with dichloromethane and analyzed on a C18 reversed-phase column eluted with a mobile phase of methanol:water at a flow rate of 0.75 ml/min. Ultraviolet absorption at 254 nm is used for detection and quantitation is performed by peak height ratio measurement. Using 200 microliters of serum, the lower limit of detection for cortisol is 10 ng/ml, the analytical recovery is 104 +/- 3.6% (n = 8), and the day-to-day precision was 1.69% at a level of 90 ng/ml (n = 16). Cortisol values obtained by this method were generally lower than those obtained by radioimmunoassay or by fluorometry. A serum pool was analyzed both by HPLC and by isotope dilution/mass spectrometry (ID/MS). A mean value of 90.1 ng/ml was obtained by HPLC (n = 16, CV = 1.7%), whereas ID/MS yielded a mean of 90.8 ng/ml (n = 28, CV = 0.4%). These results clearly demonstrate the high specificity and the accuracy of the HPLC procedure. The use of two internal standards not only compensates for losses during the sample manipulation but also prevents erroneous results in case of medication by either of these two products.  相似文献   

7.
Monoclonal antibodies specific to prostatic acid phosphatase (PAP) isoenzyme 2 were generated by using an improved hybridoma technique. After three subcutaneous immunizations and three intravenous boosters, cell fusion experiments were performed. The hybrid cells were first cultured in a semisolid medium containing methylcellulose and later transferred to a liquid medium for further subculture. Out of a total of 600 colonies recovered after two cell fusion experiments, 13 were shown to exhibit affinity to PAP isoenzyme 2 by radioimmunoassay. Nine hybrid cell lines which showed high affinity and specificity were established for further evaluation. Their immunoglobulin subclass was determined to be immunoglobulin G. The association constants between PAP isoenzyme 2 and each monoclonal antibody were determined by titration curve in radioimmunoassay (RIA). Three of them (PAP 1, PAP 03, and PAP 019) were shown to be over 1 X 10(9) M-1. From the results of a matrix cross-matching procedure, a pair of antibodies (PAP 03 and PAP 1) reacting with discrete antigenic determinants were identified for preparing a solid phase sandwich enzyme immunoassay (EIA) kit. The designed EIA procedure could be performed within 40 min in a one-stage incubation protocol. The assay time was shorter than that of other commercial RIA or EIA kits, and the sensitivity was 0.4 ng/ml which was comparable to that of RIA kits. The EIA kit was shown not to cross-react with human thyroid stimulating hormone, alpha-fetoprotein, carcinoembryonic antigen, and acid phosphatases derived from tissues other than prostate. Therefore, this design was a simple and rapid method with high sensitivity and specificity for determining PAP isoenzyme 2 in human serum.  相似文献   

8.
By using an improved hybridoma technique, monoclonal antibodies specific to alpha-fetoprotein (AFP) were generated. After three subcutaneous immunizations and three intravenous boosters, cell fusion experiments were performed. The hybrid cells were initially cultured in a semisolid medium containing methylcellulose and later transferred to a liquid medium for subculture. Out of 800 colonies recovered after two cell fusion experiments, 16 were shown to exhibit affinity to AFP by radioimmunoassay. Six hybrid cell lines which showed high affinity and specificity were selected for further evaluation. From the results of a cross-matching procedure, two pairs of antibodies (AFP 3 and AFP 05; AFP 3 and AFP 013) reacting with discrete antigenic determinants were identified for preparing solid-phase sandwich enzyme immunoassay (EIA) kits. The association constants between AFP and these three antibodies (AFP 3, AFP 05, and AFP 013) were 2.0, 3.7, and 3.8 X 10(9) M-1, respectively. The immunoglobulin subclass of them was determined to be IgG1. The EIA procedure designed could be performed within 40 min in a one-stage incubation and 70 min in a two-stage incubation. The incubation time was shown to be equal to or shorter than that of any other known commercial kits and the sensitivity was less than 1 IU/ml. In order to avoid the high-dose hook effect which occurred in the one-stage incubation procedure, a two-stage incubation protocol was advised.  相似文献   

9.
In this paper we elaborate a one-step procedure for the selective extraction of urinary 11-dehydrothromboxane B2 on octylsilyl silica cartridges for reliable determination with radioimmunoassay. The immunoreactivity profile of nonselectively extracted urine after HPLC separation showed that as much as 70% of the total 11-dehydrothromboxane B2 immunoreactivity comigrates with polar interfering material. Its amount could be considerably decreased using acetonitrile:water (18:82, v/v) as wash solvent before elution of 11-dehydrothromboxane B2 from the cartridge. Alternatively, very high immunoreactive purity was achieved without the preceding wash step by selective elution of the analyte with dichloromethane:hexane (70:30). After both optimized steps in the extraction procedure were combined, immunoreactivity was found only in HPLC fractions corresponding to the retention volume of authentic 11-dehydrothromboxane B2. The homogeneity of this immunoreactivity was confirmed by two-step HPLC separation. A significant correlation of values was observed between samples measured after extraction and those measured after subsequent HPLC purification. A high correlation was also found with concentrations determined by radioimmunoassay using four different antisera. The values of 24 h excretion of 11-dehydrothromboxane B2 in 10 male volunteers (595 +/- 114 ng/g creatinine, mean +/- SD) as well as the inhibitory effect of acetylsalicylic acid (80 +/- 13%) closely correspond with those reported in the literature. This selective extraction procedure provides a high validity in radioimmunoassay without requiring any further purification step.  相似文献   

10.
Plasma B-Endorphin (B-EP), Growth Hormone (GH) and cortisol response to 100 mcg/m2 b.s., i.v. clonidine (an alpha 2-adrenergic agonist) were evaluated in 17 normal weight children (8 prepubertal and 9 pubertal) and in 15 children with simple exogenous obesity (7 prepubertal and 8 pubertal, weight excess ranging from 29% to 97%). All the hormones were measured by radioimmunoassay either directly in the plasma (GH and cortisol) or after extraction and chromatography (B-EP). Obese prepubertal and pubertal children showed basal B-EP levels significantly higher than in controls and no differences were found in GH and cortisol levels. While in controls clonidine stimulated a significant release of plasma GH and B-EP in obese patients, irrespective of pubertal development, no changes were found. Cortisol levels decreased in both groups. These data suggest an impaired adrenergic control of GH and B-EP secretion in children with simple exogenous obesity.  相似文献   

11.
The use of cortisol levels as a measure of stress is often complicated by the use of invasive techniques that may increase hypothalamic-pituitary-adrenal (HPA) axis activity during sample collection. The goal of this study was to collect samples noninvasively and validate an enzyme-immunoassay (EIA) for the measurement of cortisol in urine to quantify HPA axis activity in the bearded emperor tamarin (Saguinus imperator subgrisescens). Urine samples were collected from trained subjects between 0700 and 0730 hr during a 1-month period, and were pooled for immunological validation. We validated the assay immunologically by demonstrating specificity, accuracy, precision, and sensitivity. For biological validation of the assay, we showed that levels of urinary cortisol (in samples collected between 0700 and 1700 hr) varied significantly across the day. Cortisol concentration was lowest at 0700 hr, increased to a mid-morning peak (0900 hr), and declined across the remainder of the day in a typical mammalian circadian pattern. We thus demonstrate that urinary cortisol can be used to quantify HPA activity in S.i. subgrisescens.  相似文献   

12.
Commercially available enzyme immunoassay (EIA) kits were validated for measuring steroid hormone concentrations in blood plasma from three fish species: the orange clownfish Amphiprion percula, the orangefin anemonefish Amphiprion chrysopterus and the blacktip reef shark Carcharhinus melanopterus. A minimum of 5 µl plasma was required to estimate hormone concentrations with both kits. These EIA kits are a simple method requiring minimal equipment, for measuring hormone profiles under field conditions.  相似文献   

13.
Cortisol and aldosterone levels were measured in plasma of eastern cottontail rabbits (Sylvilagus floridanus) collected by three different methods, i.e., shooting, live-trapping and falconry. Cortisol levels ranged from near 0 to 27.5 micrograms/100 ml and aldosterone from near 0 to 220 ng/100 ml. Shot animals had significantly lower cortisol concentrations than those taken by either of the other methods. Trapped cottontails also had significantly lower aldosterone levels.  相似文献   

14.
We compared five methods for improved extraction of very-large parapoxvirus DNA from infected cells: (i) alkaline-lysis procedure followed by phenol extraction; (ii) modified Hirt procedure, which was a neutral lysis procedure followed by phenol extraction; (iii) Hirt procedure; (iv) method used for extraction of vaccinia virus DNA; and (v) standard procedure using virus purification with an ultracentrifuge and protease-sodium dodecyl sulfate-phenol treatment. The alkaline-lysis procedure was more rapid, inexpensive and simpler than the other methods. Moreover, with this method it is not necessary to prepare any special facilities, reagents and kits. Although the extracted DNA was still crude, we could reproducibly prepare viral DNA from 2 X 10(6) infected cells in less than 2 hr and it could be readily digested by restriction endonuclease. This method will aid rapid genetic classification of parapoxvirus.  相似文献   

15.
本文报道对清洁级实验动物应排除的四种病毒(淋巴细胞脉络丛脑膜炎病毒、小鼠脱脚病病毒、鼠肝炎病毒和仙台病毒)抗体玻片酶免疫(EIA)检测试剂盒的研制。四种病毒感染的细胞和对照细胞经冷丙酮固定于载玻片上制成特异性抗原和对照抗原,此四种病毒的抗血清各10份和SPF小鼠血清20份分别与四种病毒的特异性抗原和对照抗原进行EIA交叉试验,结果显示,抗原只与其相应抗血清发生特异性显色反应,与非特异性小鼠血清和SPF小鼠血清不显色。与HI或ELISA方法比较,通过对112份普通小鼠血清进行测试,结果表明,EIA对仙台病毒抗体的检出率(19.6%)显著高于(<0.005)HI(6.3%),对小鼠脱脚病病毒抗体的检出率(23.3%)与HI(21.4%)无显著性差异(P>0.05)。EIA对淋巴细胞脉络丛脑膜炎病毒和鼠肝炎病毒抗体的检出率分别为1.8%和71.2%,ELISA对两种病毒抗体的检出率分别为1.8%和67.6%,两种方法对两种病毒抗体的检出率无显著性差异(P>0.05)。重复性试验表明两批四种病毒抗体试剂盒对108份小鼠血清两次测定的符合率为96~100%。四种病毒的EIA抗原在-18℃保存12个月或在2-8℃保存3  相似文献   

16.
Patterns of cortisol reactivity to laboratory stress   总被引:1,自引:0,他引:1  
Cortisol responses to a laboratory stress protocol were investigated in 82 male firefighters. Saliva samples were collected during an adaptation period beginning between 9 and 10 am, and then at the end of each of six 10-min trials (a mental arithmetic task, an inter-task recovery period, a speech task, and three recovery periods). Individual differences in the mean cortisol response to the stress tasks were characterized by variation in the direction of the response, as well as the size of the response. Neither pre-stress cortisol levels nor responses were correlated with cardiovascular and mood responses. Cortisol levels before stress task presentation were negatively correlated with recent stress severity. Larger mean cortisol responses were associated with lower reports of recent stress exposure, lower negative affect scores, and a coping style characterized less experience of anger, more control over anger expression, and a tendency to screen out threatening information in stressful situations. Thus, increased cortisol activity was associated with less recent stress exposure and a more adaptive behavioral style than for those whose cortisol levels fell or were largely unchanged in response to a laboratory stressor.  相似文献   

17.
A rapid high-performance liquid chromatographic (HPLC) method for the simultaneous determination of cortisol and cortisone in a single extract of 1 ml of serum is described. The method employs meprednisone as the internal standard. The steroids were analysed isocratically by reversed-phase HPLC with an octadecylsilane-bonded (ODS) column using ultraviolet detection. The matrix effect was reduced by lowering the sample pH by adding glacial acetic acid to the sera. The samples were then filtered through regenerated cellulose membranes at 4°C and extracted with diethyl ether. The dried eluates were redissolved in the mobile phase and injected into the column. The detection limit of the assay for both steroids was 500 ng/l. Cortisol was determined in twenty serum samples by both HPLC and radioimmunoassay (RIA). The results were similar. Interference by other steroids and certain steroid analogue drugs was also studied. The HPLC method yielded no cross-reactivity between the different steroids as may occur with the RIA technique. The HPLC method was technically easy to perform and it allowed us to quantify both cortisol and cortisone in a single serum extract with high specificity.  相似文献   

18.
Stress-like levels of cortisol inhibit sexual receptivity in ewes but the mechanism of this action is not understood. One possibility is that cortisol interferes with the actions of oestradiol to induce sexual receptivity. We tested this hypothesis in 2 experiments with ovariectomised ewes that were artificially induced into oestrus by 12 days of i.m. injections of progesterone followed by an i.m. injection of oestradiol benzoate (ODB) 48 h later. In Experiment 1, ewes were randomly allocated to the following groups: saline infusion + 25 μg ODB, saline infusion + 50 μg ODB, cortisol infusion + 25 μg ODB or cortisol infusion + 50 μg ODB (n = 5 per group). Saline or cortisol was infused i.v. for 40 h beginning at the ODB injection. In Experiment 2, ewes were infused with saline or cortisol (n = 5 per group) for 5 h beginning 1 h before ODB injection. In both experiments, ewe sexual behaviour (attractivity, proceptivity and receptivity) was quantified every 6 h. Blood samples were also collected. The cortisol infusion yielded plasma concentrations of cortisol similar to those seen during psychosocial stress. In both experiments, cortisol suppressed receptivity index (number of immobilisations by ewe/courtship displays by ram) and the number of times ewes were mounted but had no effect on attractivity or proceptivity, irrespective of the dose of ODB (Experiment 1). Cortisol also suppressed LH pulse amplitude. These results suggest that both an acute (5 h) and chronic (40 h) infusion of cortisol inhibit oestradiol-induced sexual receptivity in ewes and that increasing the dose of ODB does not overcome the inhibitory effects of cortisol.  相似文献   

19.
Cortisol 21-amine (21-amino-11β,17-dihydroxy-4-pregnene-3,20-dione) was prepared and an enzyme immunoassay for cortisol in serum was established using cortisol 21-amine conjugated with alkaline phosphatase. The minimal amount of cortisol detected was 1ng/tube and the measurable range was from 1 to 80 μg/d1, using 10 μ1 of serum sample. This enzyme immunoassay satisfied the standard criteria of dilution, accuracy and precision. The values correlated well with those obtained by radioimmunoassay. This enzyme Immunoassay is applicable to the routine determination of serum cortisol in any clinical laboratory. Cortisol 21-amine was found to be a useful derivative for preparing cortisol-enzyme conjugate in enzyme immunoassay.  相似文献   

20.
The hepatotoxin cylindrospermopsin (CYN) is a potent inhibitor of protein synthesis in mammalian cells. It is produced by freshwater cyanobacterial blooms in countries such as Australia, the United States, Israel, Thailand, and Brazil. An interlaboratory comparison was organized as a first step to evaluate the measurement of CYN in lyophilized cyanobacterial cells. Six laboratories from Europe, Israel, and Australia participated in the trial. All of the methods used for extraction of the toxin and the high-performance liquid chromatography (HPLC) analysis were satisfactory on the basis of statistical evaluation, according to ISO standards 5725-1 and -2. Further comparison of all the extraction methods by the organizer indicated that the most effective extraction procedure used 5% formic acid to prevent interference in chromatograms by contaminant compounds when analyzed using HPLC employing isocratic conditions of 5% (v/v) aqueous methanol plus 0.1% (v/v) trifluoroacetic acid as the mobile phase.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号