首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Several novel selenium containing compounds were characterized in staple crops (wheat, rice and maize) grown on soils naturally rich in selenium. A dedicated method based on the coupling of liquid chromatography with multiplexed detection (ICP-MS, ESI-Orbitrap MS(/MS)) was developed for the speciation of low-molecular weight (<5 kDa) selenium metabolites. Nine species present in different proportions as a function of the crop type were identified by cation-exchange HPLC-ESI-Orbitrap MS on the basis of the accurate molecular mass and MS/MS spectra. The natural origin of these species was then validated by varying extraction conditions and by using hydrophilic interaction LC (HILIC)-ESI-Orbitrap MS(/MS). Among the identified compounds, Se-containing monosaccharides (hexose moiety, m/z 317 and m/z 358) or Se-containing disaccharides (hexose-pentose moiety, m/z 407 and m/z 408) were the first selenosugars reported in edible plants. It is also the first report of the presence of 2,3-dihydroxypropionyl-selenolanthionine (m/z 345) in rice. Because these crops can be an important source of selenium in animal and human nutrition, the understanding of the origin and the fate of these species during metabolic processes will be of great interest.  相似文献   

2.
Strong cation exchange HPLC with the parallel ICP MS and electrospray hybrid linear ion trap quadrupole orbital trap mass spectrometry (ESI Orbitrap MS) detection was developed for the study of the metabolomic pattern of selenium in selenium-rich yeast. The mobile phase composition (gradient of ammonium formate in 20% methanol) was optimized to obtain separation in conditions guaranteeing the identical ICP MS sensitivity during the entire chromatographic run and the compatibility with electrospray ionization. Twenty seven Se-containing metabolites observed in the HPLC-ICP MS chromatogram were identified by ESI Orbitrap MS based on the Se isotopic pattern, the accurate molecular mass, and the multistage fragmentation patterns. The method allowed for the first time the correlation of the differences observed in HPLC-ICP MS chromatography of water extracts of Se-rich yeast samples from different manufacturers with the identity of the eluted compounds determined by ESI MS.  相似文献   

3.
Soybean (Glycine Max) plants were grown in soil supplemented with sodium selenite. A comprehensive selenium profile, including total selenium concentration, distribution of high molecular weight selenium and characterization of low molecular weight selenium compounds, is reported for each plant compartment: bean, pod, leaf and root of the Se-enriched soybean plants. Two chromatographic techniques, coupled with inductively coupled plasma mass spectrometry (ICPMS) for specific selenium detection, were employed in this work to analyze extract solutions from the plant compartments. Size-exclusion chromatography revealed that the bean compartment, well-known for its strong ability to make proteins, produced high amounts (82% of total Se) of high molecular weight selenospecies, which may offer additional nutritional value and suggest high potential for studying proteins containing selenium in plants. The pod, leaf and root compartments primarily accumulate low molecular weight selenium species. For each compartment, low molecular weight selenium species (lower than 5 kDa) were characterized by ion-pairing reversed phase HPLC-ICPMS and confirmed by electrospray ionization ion trap mass spectrometry (ESI-ITMS). Selenomethionine and selenocystine are the predominant low molecular weight selenium compounds found in the bean, while inorganic selenium was the major species detected in other plant compartments.  相似文献   

4.
An analytical approach allowing the identification of unknown selenium metabolites in selenium-rich yeast was described. Anion-exchange HPLC of the Se-metabolome fraction co-eluting with salts in size-exclusion chromatography allowed the separation of nine selenium species (excluding isomers and selenate) as monitored by inductively coupled plasma mass spectrometry (ICP MS). The individual fractions were analyzed by electrospray QTOF MS/MS and hybrid linear ion trap/Orbitrap MSn after sample introduction by reversed-phase nanoHPLC and by hydrophilic interaction LC (HILIC), respectively. Out of the nine detected species, eight were identified on the basis of accurate mass measurements and collision induced dissociation/fragmentation information. Seven Se-species (selenohomolanthionine, γ-Glu-selenocystathionine, 2,3-DHP-selenocystathionine, N-acetyl-selenocystathionine, 2,3-DHP-selenohomolanthionine, Se-methyl-selenoglutathione, and 2,3-DHP-Se-methylselenocysteine) were reported for the first time in Se-rich yeast, five of them have never been reported in any biological sample before.  相似文献   

5.
Complete structural elucidation of natural products is commonly performed by nuclear magnetic resonance spectroscopy (NMR), but annotating compounds to most likely structures using high-resolution tandem mass spectrometry is a faster and feasible first step. The CASMI contest 2016 (Critical Assessment of Small Molecule Identification) provided spectra of eighteen compounds for the best manual structure identification in the natural products category. High resolution precursor and tandem mass spectra (MS/MS) were available to characterize the compounds. We used the Seven Golden Rules, Sirius2 and MS-FINDER software for determination of molecular formulas, and then we queried the formulas in different natural product databases including DNP, UNPD, ChemSpider and REAXYS to obtain molecular structures. We used different in-silico fragmentation tools including CFM-ID, CSI:FingerID and MS-FINDER to rank these compounds. Additional neutral losses and product ion peaks were manually investigated. This manual and time consuming approach allowed for the correct dereplication of thirteen of the eighteen natural products.  相似文献   

6.
Mass spectrometers that provide high mass accuracy such as FT-ICR instruments are increasingly used in proteomic studies. Although the importance of accurately determined molecular masses for the identification of biomolecules is generally accepted, its role in the analysis of shotgun proteomic data has not been thoroughly studied. To gain insight into this role, we used a hybrid linear quadrupole ion trap/FT-ICR (LTQ FT) mass spectrometer for LC-MS/MS analysis of a highly complex peptide mixture derived from a fraction of the yeast proteome. We applied three data-dependent MS/MS acquisition methods. The FT-ICR part of the hybrid mass spectrometer was either not exploited, used only for survey MS scans, or also used for acquiring selected ion monitoring scans to optimize mass accuracy. MS/MS data were assigned with the SEQUEST algorithm, and peptide identifications were validated by estimating the number of incorrect assignments using the composite target/decoy database search strategy. We developed a simple mass calibration strategy exploiting polydimethylcyclosiloxane background ions as calibrant ions. This strategy allowed us to substantially improve mass accuracy without reducing the number of MS/MS spectra acquired in an LC-MS/MS run. The benefits of high mass accuracy were greatest for assigning MS/MS spectra with low signal-to-noise ratios and for assigning phosphopeptides. Confident peptide identification rates from these data sets could be doubled by the use of mass accuracy information. It was also shown that improving mass accuracy at a cost to the MS/MS acquisition rate substantially lowered the sensitivity of LC-MS/MS analyses. The use of FT-ICR selected ion monitoring scans to maximize mass accuracy reduced the number of protein identifications by 40%.  相似文献   

7.
A gas chromatography–mass spectrometry (GC–MS) procedure was developed for the detection of 4-hydroxycoumarin anticoagulants and their metabolites in urine as part of a systematic toxicological analysis procedure for acidic drugs and poisons after extractive methylation. The part of the phase-transfer catalyst remaining in the organic phase was removed by solid-phase extraction on a diol phase. The compounds were separated by capillary GC and identified by computerized MS in the full scan mode. Using mass chromatography with the ions m/z 291, 294, 295, 309, 313, 322, 324, 336, 343 and 354, the possible presence of 4-hydroxycoumarin anticoagulants and/or their metabolites could be indicated. The identity of positive signals in such mass chromatograms was confirmed by comparison of the peaks underlying full mass spectra with the reference spectra recorded during this study. This method allowed the detection of therapeutic concentrations of phenprocoumon and warfarin in human urine samples. In absence of human urine, acenocoumarol, coumachlor, coumatetrayl, pyranocoumarin (cyclocumarol) could be detected only in rat urine.  相似文献   

8.
Speciation analysis of selenium in human urine allowed for the first time the identification of a novel selenium metabolite, Se-methylselenoneine. Despite a concentration at low ppb level, its characterization was achieved after sample purification by solid phase extraction (SPE) followed by the parallel coupling of the bidimensional RP/HILIC chromatography with ICP-MS and ESI-LTQ Orbitrap MS detection. To confirm its biological significance with regards to selenoneine, the recently discovered analog of ergothioneine, and to discard the possibility of sample preparation artifacts, a new method was developed to monitor its actual presence, as well as the occurrence of its sulfur and/or non-methylated analogs, in non-preconcentrated urine and blood samples of non-supplemented humans. It consisted in a HILIC ESI-MS(3) method in high resolution mode (resolution 30?000 at m/z 400) with large isolation width windows for precursor ions. These two particular settings allowed respectively to keep observing the specific mass defect of selenium- and sulfur-containing molecules and to maintain the characteristic selenium pattern in product ions created through MS(n) fragmentations. As a result, all four metabolites were detected in blood and three of them in urine. Moreover, different ratios "methylated/non-methylated" were observed between urine and blood samples, which seemed to indicate their active metabolization. The analytical tool developed here will be of a great importance to further study the occurrence and the potential metabolic role in mammalian organelles, cells and fluids of these very particular and promising redox metabolites.  相似文献   

9.
Comparative phytochemical analyses of hydroalcoholic (50% EtOH) extracts from roots of S. miltiorrhiza (SM) and S. przewalskii (SP) were performed using two complementary LC–MS systems: the first system HPLC-DAD-MSn an ion trap mass spectrometer and the second system consisted high resolution MS/MS Orbitrap mass spectrometer. The individual compounds were identified using a previously published approach via comparison of the exact molecular masses, mass spectra and retention times to those of standard compounds, online available databases and literature data. Moreover, the determination of antioxidative activities of extracts by DPPH and FRAP methods was carried out. Analysis allowed to identify 39 chemical compounds in extracts from both species. Extract from root of SP differs from SM in the presence of several metabolites such as: przewalskinic acid and their derivatives, przewaquinone C, przewaquinonate A, glycosides of rosmarinic acid, methyltanshinonate, whereas tanshinones, salvianolic acids and lithospermic acids occurred in both species. Moreover, it was shown that hydroalcoholic extract from roots of SM exerted stronger antioxidant properties in a FRAP test (max. 323.92 μM Fe2+/L) and in DPPH test (max. 78.64 nM TE) in comparison with SP extract.  相似文献   

10.
11.
A sampling system for on-line monitoring of organic compounds of low volatility in complex fermentation media uses membrane inlet mass spectrometry (MIMS). A Syringe pump draws a continuous flow of microfiltered broth from the reactor and circulates it after acidification through a membrane inlet, in which a membrane is the only interface between the sample and the high vacuum of a mass spectrometer. All operations run automatically, i.e., sampling, acidification measurement, and calibration. The on-stream acidification enables MIMS monitoring of carboxylic acids, as they must be undissociated in order to pass the hydrophobic membrane. The performance of the monitoring system was tested by measurements of standard solutions of phenoxyacetic acid (POAA, the sie chain precursor of penicillin-V) as well as on POAA during 200 h penicillin-V fermentation. During the entire fermentation POAA was monitored n low millimolar concentrations with high accuracy and fast response to step changes in POAA concentration. Tandem mass spectrometry (MS/MS) allowed direct identification of peaks in the mass spectrum of the broth that were not accounted for by POAA. These peaks were identified as SO(2) and SCO. (c) 1994 John Wiley & Sons, Inc.  相似文献   

12.
The identification of proteins separated on two-dimensional gels is most commonly performed by trypsin digestion and subsequent matrix-assisted laser desorption ionization (MALDI) with time-of-flight (TOF). Recently, atmospheric pressure (AP) MALDI coupled to an ion trap (IT) has emerged as a convenient method to obtain tandem mass spectra (MS/MS) from samples on MALDI target plates. In the present work, we investigated the feasibility of using the two methodologies in line as a standard method for protein identification. In this setup, the high mass accuracy MALDI-TOF spectra are used to calibrate the peptide precursor masses in the lower mass accuracy AP-MALDI-IT MS/MS spectra. Several software tools were developed to automate the analysis process. Two sets of MALDI samples, consisting of 142 and 421 gel spots, respectively, were analyzed in a highly automated manner. In the first set, the protein identification rate increased from 61% for MALDI-TOF only to 85% for MALDI-TOF combined with AP-MALDI-IT. In the second data set the increase in protein identification rate was from 44% to 58%. AP-MALDI-IT MS/MS spectra were in general less effective than the MALDI-TOF spectra for protein identification, but the combination of the two methods clearly enhanced the confidence in protein identification.  相似文献   

13.
A novel derivatization method employing 1,2-dimethylimidazole-4-sulfonyl chloride (DMISC) to improve the mass spectrometric response for phenolic compounds in liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) and tandem mass spectrometry (LC-ESI-MS/MS) is described. Several environmentally relevant compounds, including chloro-, aryl- and alkylphenols, steroidal estrogens, and hydroxy-polycyclic aromatic hydrocarbons (OHPAHs), were selected to evaluate this technique. A facile derivatization procedure employing DMISC results in dimethylimidazolesulfonyl (DMIS) derivatives that are stable in aqueous solution. These DMIS derivatives produced intense [M+H](+) ions in positive-ion LC-ESI-MS. The product ion spectra of the [M+H](+) ions of simple phenols were dominated by ions representing the DMIS and dimethylimidazole moieties, whereas product ion spectra of the DMIS derivatives of OHPAHs with three or more fused aromatic rings showed prominent ArO(+) ions, the relative intensity of which increased with the number of rings. The DMIS derivatives of the selected phenolic compounds showed excellent chromatographic properties. To substantiate the utility of derivatization with DMISC, an analytical method employing enzyme hydrolysis, solid phase extraction, derivatization with DMISC, and analysis by LC-ESI-MS/MS with multiple reaction monitoring for determination in human urine of 1-hydroxypyrene, a widely used biomarker for the assessment of human exposure to PAHs, was developed and validated.  相似文献   

14.
Direct-infusion mass spectrometry (MS) was applied to study the metabolic effects of the symbiosis between the endophytic fungus Neotyphodium lolii and its host perennial ryegrass (Lolium perenne) in three different tissues (immature leaf, blade, and sheath). Unbiased direct-infusion MS using a linear ion trap mass spectrometer allowed metabolic effects to be determined free of any preconceptions and in a high-throughput fashion. Not only the full MS(1) mass spectra (range 150-1,000 mass-to-charge ratio) were obtained but also MS(2) and MS(3) product ion spectra were collected on the most intense MS(1) ions as described previously (Koulman et al., 2007b). We developed a novel computational methodology to take advantage of the MS(2) product ion spectra collected. Several heterogeneous MS(1) bins (different MS(2) spectra from the same nominal MS(1)) were identified with this method. Exploratory data analysis approaches were also developed to investigate how the metabolome differs in perennial ryegrass infected with N. lolii in comparison to uninfected perennial ryegrass. As well as some known fungal metabolites like peramine and mannitol, several novel metabolites involved in the symbiosis, including putative cyclic oligopeptides, were identified. Correlation network analysis revealed a group of structurally related oligosaccharides, which differed significantly in concentration in perennial ryegrass sheaths due to endophyte infection. This study demonstrates the potential of the combination of unbiased metabolite profiling using ion trap MS and advanced data-mining strategies for discovering unexpected perturbations of the metabolome, and generating new scientific questions for more detailed investigations in the future.  相似文献   

15.
HPLC-MS using collision induced dissociation (CID) has been utilised for the identification of the C-glycosylflavone isomer pairs orientin/isoorientin and vitexin/isovitexin. HPLC-CID/MS analyses produced pseudo-MS/MS spectra that allowed the identification of the flavone C-glycosides. The efficient differentiation of isomers was performed by comparing the CID-MS/MS spectra (including exact mass measurements) of particular fragments from the C-glycoside unit. In order to illustrate some possibilities of these MS techniques, they were applied to the comparative analyses of extracts of Passiflora alata, P. edulis, P. incarnata and P. caerulea (Passifloraceae) that are employed as phytomedicines in Brazil and South America.  相似文献   

16.
The characteristics of the mass spectra of vitamin D3 related compounds were investigated by GC–MS and LC–MS using 22-oxacalcitriol (OCT), an analog of 1,25-dihydroxyvitamin D3, and related compounds. Fragmentation during GC–MS (electron impact ionization) of TMS-derivatives of OCT and the postulated metabolites gave useful structural information concerning the vitamin D3-skeleton and its side-chain, especially with respect to the oxidation positions of metabolites. In contrast, few fragment ions were observed in LC–MS (atmospheric pressure chemical ionization), showing that LC–MS gave poor structural information, except for molecular mass. However, when comparing the signal-to-noise ratio (S/N) observed during GC–MS and LC–MS analysis for OCT in plasma extracts, the S/N in LC–MS was over ten-times greater than in GC–MS, possibly due to the low recovery on derivatization and thermal-isomerization in GC–MS. Furthermore, both the GC–MS and the LC–MS allowed the analysis of many postulated metabolites in a single injection without any prior isolation of target metabolites from biological fluids by LC. These results suggest that GC–MS and LC–MS analysis for vitamin D3 related compounds such as OCT each have unique and distinct advantages. Therefore, the complementary use of both techniques enables the rapid and detailed characterization of vitamin D3 related compounds.  相似文献   

17.
Identification of proteins by MS/MS is performed by matching experimental mass spectra against calculated spectra of all possible peptides in a protein data base. The search engine assigns each spectrum a score indicating how well the experimental data complies with the expected one; a higher score means increased confidence in the identification. One problem is the false-positive identifications, which arise from incomplete data as well as from the presence of misleading ions in experimental mass spectra due to gas-phase reactions, stray ions, contaminants, and electronic noise. We employed a novel technique of reduction of false positives that is based on a combined use of orthogonal fragmentation techniques electron capture dissociation (ECD) and collisionally activated dissociation (CAD). Since ECD and CAD exhibit many complementary properties, their combined use greatly increased the analysis specificity, which was further strengthened by the high mass accuracy (approximately 1 ppm) afforded by Fourier transform mass spectrometry. The utility of this approach is demonstrated on a whole cell lysate from Escherichia coli. Analysis was made using the data-dependent acquisition mode. Extraction of complementary sequence information was performed prior to data base search using in-house written software. Only masses involved in complementary pairs in the MS/MS spectrum from the same or orthogonal fragmentation techniques were submitted to the data base search. ECD/CAD identified twice as many proteins at a fixed statistically significant confidence level with on average a 64% higher Mascot score. The confidence in protein identification was hereby increased by more than 1 order of magnitude. The combined ECD/CAD searches were on average 20% faster than CAD-only searches. A specially developed test with scrambled MS/MS data revealed that the amount of false-positive identifications was dramatically reduced by the combined use of CAD and ECD.  相似文献   

18.
Our laboratory has been asked to elucidate the origin of a strong “toxic smell” present in a prominent politician's office, private house and motorcar. This stinky and pungent atmosphere has caused serious nausea and vomiting to several individuals. Urine samples were collected from the persons presenting symptoms of nausea for toxicological analysis. Drops, paper and cotton swabs of an oily liquid found at the implicated places were submitted by police to our laboratory for investigation. Methanol extracts of the drops were acetylated for gas chromatography/mass spectrometry (GC/MS) analysis in the electron impact mode; the cotton and paper swabs were analysed using headspace-gas chromatography/mass spectrometry (HS-GC/MS). The GC/MS analysis of the acetylated methanol extracts revealed that the major peaks of the chromatogram could be attributed to 2-methylquinoline, to 2-quinolinemethanethiol, to S-2-quinolinemethyl thioacetate, to 2-phenylethanethiol, to bis(E)-2-butenyl disulphide and to bis(3-methylbutyl) disulphide. Several volatile sulphur-containing compounds have been identified with the HS-GC/MS system. Detailed examination of the spectra as well as GC/MS analysis of commercially available skunk secret allowed us to relate the identified compounds to those present in the defence spray of skunks. No health sequels were observed for any of the persons implicated in this case.  相似文献   

19.
A gas chromatographic mass spectrometric assay for clonidine in plasma with a detection limit of a few picograms per ml was required. The p-trifluoromethylbenzyl, pentafluorobenzyl and pentafluorobenzoyl derivatives of clonidine were synthesized and the electron capture negative ion chemical ionization mass spectra of these compounds show extensive fragmentation with prominent ions at m/z 35 and 37 due to the two chlorine atoms in the clonidine molecule. Selected ion monitoring of specific high mass ions in these mass spectra indicated that the required sensitivity could not be obtained with these derivatives. Several bis(trifluoromethyl)pyrimidines were synthesized and these compounds were found to give an intense negative ion current under conditions of resonance electron capture. Consequently, a derivative of clonidine containing a bis(trifluoromethyl)aryl group was synthesized by reacting the drug with 3,5-bis(trifluoromethyl)benzoyl chloride. The negative ion mass spectrum of the reaction product has a base peak at m/z 673 and, when this ion is specifically monitored, an amount of derivative equivalent to 1 picogram of clonidine can be detected. This allowed the development of an assay for clonidine in plasma with a precision of 8% (SD) at 50 pg ml-1, 22% (SD) at 20 pg ml-1 and a lower limit for quantitative determination of 10 pg ml-1. Plasma concentrations of clonidine in 10 subjects given a single 50 micrograms oral dose are reported.  相似文献   

20.
This work presents a novel database search engine – MLibrary – designed to assist the user in the detection and identification of androgenic anabolic steroids (AAS) and its metabolites by matrix assisted laser desorption/ionization (MALDI) and mass spectrometry-based strategies. The detection of the AAS in the samples was accomplished by searching (i) the mass spectrometric (MS) spectra against the library developed to identify possible positives and (ii) by comparison of the tandem mass spectrometric (MS/MS) spectra produced after fragmentation of the possible positives with a complete set of spectra that have previously been assigned to the software. The urinary screening for anabolic agents plays a major role in anti-doping laboratories as they represent the most abused drug class in sports. With the help of the MLibrary software application, the use of MALDI techniques for doping control is simplified and the time for evaluation and interpretation of the results is reduced. To do so, the search engine takes as input several MALDI-TOF–MS and MALDI-TOF–MS/MS spectra. It aids the researcher in an automatic mode by identifying possible positives in a single MS analysis and then confirming their presence in tandem MS analysis by comparing the experimental tandem mass spectrometric data with the database. Furthermore, the search engine can, potentially, be further expanded to other compounds in addition to AASs. The applicability of the MLibrary tool is shown through the analysis of spiked urine samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号