首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Diagnosis of murine infections in relation to test methods employed   总被引:1,自引:0,他引:1  
Comparative investigations of Sendai virus, pneumonia virus of mice (PVM), mouse encephalomyelitis virus (mouse polio), minute virus of mice (MVM), and reovirus type 3 (Reo 3) infected murine colonies revealed a 30% higher incidence of positive sera when enzyme-linked immunosorbent assay (ELISA) was employed instead of hemagglutination inhibition (HI) tests. Equivalent sensitivity as in the ELISA was obtained when the same sera were investigated by indirect immunofluorescence (IF) tests. The virus purification techniques described resulted in highly suitable antigens for all indirect ELISA established. Since IIF requires no purified antigens, this test is recommended as an alternative to ELISA as well as to HI and complement fixation (CF) tests for laboratories lacking the necessary equipment for high speed centrifugation. A high incidence of false positive HI reactions was found particularly in Reo 3 routine serology. An updated survey of seromonitoring showed that European murine colonies appeared to be infected far less with Reo 3 if ELISA or IIF tests were employed. During 1982-1984, only 13% of the mouse colonies screened possessed Reo 3 positive sera whereas no natural Reo 3 infection was found in rat colonies. Mouse hepatitis virus (MHV) and the coronaviruses of rats exhibited the highest incidence in murine colonies. A total of 60% of mouse and 41% of rat colonies were found to be infected by these viruses. In comparison with earlier serological surveys, the relative incidence of other murine infections was similar. Antibodies against Bacillus piliformis (Tyzzer's disease) were detected by the IIF test in 41% of the rat colonies screened.  相似文献   

2.
Shiga-like toxin-producingEscherichia coli O157:H7 are important causes of bloody diarrhea and hemolytic uremic syndrome. To facilitate the epidemiologic study of these organisms, we developed enzyme-linked immunosorbent assays (ELISAs) for antibodies to Shiga-like toxin I (SLT I), Shiga-like toxin II (SLT II), andE. coli O157 lipopolysaccharide (LPS). We tested serum samples from 83 patients in two outbreaks ofE. coli O157:H7 diarrhea and from 66 well persons. Forty-three patients (52%) had at least one serum sample positive for anti-O157 LPS antibodies; among 26 culture-confirmed patients, 24 (92%) had at least one positive serum sample. Two (3%) of 66 control sera had positive anti-O157 LPS titers. ELISA results for SLT I and II were compared with those of HeLa cell cytotoxicity neutralization assays on both patient and control sera. Neutralization assays detected anti-SLT I antibodies in at least one serum sample from each of 17 (20%) patients and 7 (10.6%) controls, while 16 (19%) patients and 7 controls had positive titers by anti-SLT I ELISA. Although all serum samples, including control sera, showed nonspecific neutralization of SLT II, no antibody titers to SLT II were detected by either neutralization or ELISA. These results indicate that ELISAs for SLT I and SLT II antibodies are comparable to HeLa cell cytotoxicity neutralization assays. Both the ELISAs and neutralization assays are insensitive in detecting infected patients. However, the ELISA for antibodies toE. coli O157 LPS is both sensitive and specific, and may be more useful than assays for antitoxic antibodies in detecting persons withE. coli O157:H7 infection.  相似文献   

3.
Anti-neutrophil cytoplasmic antibodies (ANCA) are the serological hallmark of small vessel vasculitis, so called ANCA-associated vasculitis. The international consensus requires testing by indirect immunofluorescence (IIF) on human ethanol-fixed neutrophils (ethN) as screening followed by confirmation with enzyme-linked immunosorbent assays (ELISAs). This study evaluates the combination of cell- and microbead-based digital IIF analysis of ANCA in one reaction environment by the novel multiplexing CytoBead technology for simultaneous screening and confirmatory ANCA testing. Sera of 592 individuals including 118 patients with ANCA-associated vasculitis, 133 with rheumatoid arthritis, 49 with infectious diseases, 77 with inflammatory bowel syndrome, 20 with autoimmune liver diseases, 70 with primary sclerosing cholangitis and 125 blood donors were tested for cytoplasmic ANCA (C-ANCA) and perinuclear ANCA (P-ANCA) by classical IIF and ANCA to proteinase 3 (PR3) and myeloperoxidase (MPO) by ELISA. These findings were compared to respective ANCA results determined by automated multiplex CytoBead technology using ethN and antigen-coated microbeads for microbead immunoassays. There was a good agreement for PR3- and MPO-ANCA and a very good one for P-ANCA and C-ANCA by classical and multiplex analysis (Cohen''s kappa [κ] = 0.775, 0.720, 0.876, 0.820, respectively). The differences between classical testing and CytoBead analysis were not significant for PR3-ANCA, P-ANCA, and C-ANCA (p<0.05, respectively). The prevalence of confirmed positive ANCA findings by classical testing (IIF and ELISA) compared with multiplex CytoBead analysis (IIF and microbead immunoassay positive) resulted in a very good agreement (κ = 0.831) with no significant difference of both methods (p = 0.735). Automated endpoint-ANCA titer detection in one dilution demonstrated a very good agreement with classical analysis requiring dilution of samples (κ = 0.985). Multiplexing by CytoBead technology can be employed for simultaneous screening and quantitative confirmation of ANCA. This novel technique provides fast and cost-effective ANCA analysis by automated digital IIF for the first time.  相似文献   

4.
Abstract Two enzyme-linked immunosorbent assays (ELISA) using highly purified elementary bodies (EB) of Chlamydia psittaci A/22 strain (ovine) or 6BC strain (psittacine) were set up for the detection of antichlamydial antibodies in sheep. No significant differences were observed between the two ELISAs, whereas these tests proved to be more sensitive than complement fixation test and showed a good correlation ( r = 0.75) with immunofluorescence assay. The periodate treatment of chlamydial antigens modified the results of serological responses studied by ELISA, depending on the sera. The average reduction of ELISA values by periodate was 28%, ranging between 5% and 65%. The immunoblot analysis of sheep sera showed high cross reactivity between the polypeptides of A/22 and 6BC strains. However, some differences were observed. The major outer membrane protein (MOMP) of 6BC strain was recognized at different molecular weight position (40 000 kDa) in comparison with the MOMP of A/22 strain (38 000 kDa). In addition, a clear band of 97 000 kDa was detected by all sheep sera tested with A/22 strain. This band was undetectable in the blots performed with 6BC strain.  相似文献   

5.
Two enzyme-linked immunosorbent assays (ELISA) using highly purified elementary bodies (EB) of Chlamydia psittaci A/22 strain (ovine) or 6BC strain (psittacine) were set up for the detection of antichlamydial antibodies in sheep. No significant differences were observed between the two ELISAs, whereas these tests proved to be more sensitive than complement fixation test and showed a good correlation (r = 0.75) with immunofluorescence assay. The periodate treatment of chlamydial antigens modified the results of serological responses studied by ELISA, depending on the sera. The average reduction of ELISA values by periodate was 28%, ranging between 5% and 65%. The immunoblot analysis of sheep sera showed high cross reactivity between the polypeptides of A/22 and 6BC strains. However, some differences were observed. The major outer membrane protein (MOMP) of 6BC strain was recognized at different molecular weight position (40,000 kDa) in comparison with the MOMP of A/22 strain (38,000 kDa). In addition, a clear band of 97,000 kDa was detected by all sheep sera tested with A/22 strain. This band was undetectable in the blots performed with 6BC strain.  相似文献   

6.
Indirect enzyme-linked immunosorbent assays (ELISAs) based on recombinant major surface protein 5 (rMSP5) and initial body (IB) antigens from a Brazilian isolate of Anaplasma marginale were developed to detect antibodies against this rickettsia in cattle. Both tests showed the same sensitivity (98.2%) and specificities (100% for rMSP5 and 93.8% for IB ELISA) which did not differ statistically. No cross-reactions were detected with Babesia bigemina antibodies, but 5 (rMSP5 ELISA) to 15% (IB ELISA) of cross-reactions were detected with B. bovis antibodies. However, such difference was not statistically significant. Prevalences of seropositive crossbred beef cattle raised extensively in Miranda county, state of Mato Grosso do Sul, Brazil, were 78.1% by rMSP5 ELISA and 79.7% by IB ELISA. In the analysis of sera from dairy calves naturally-infected with A. marginale, the dynamics of antibody production was very similar between both tests, with maternal antibodies reaching the lowest levels at 15-30 days, followed by an increase in the mean optical densities in both ELISAs, suggesting the development of active immunity against A. marginale. Results showed that all calves were seropositive by one-year old, characterizing a situation of enzootic stability. The similar performances of the ELISAs suggest that both tests can be used in epidemiological surveys for detection of antibodies to A. marginale in cattle.  相似文献   

7.

Background

Avian influenza virus (AIV) subtypes H5 and H7 attracts particular attention because of the risk of their potential pathogenicity in poultry. The haemagglutination inhibition (HI) test is widely used as subtype specific test for serological diagnostics despite the laborious nature of this method. However, enzyme-linked immunosorbent assays (ELISAs) are being explored as an alternative test method.H5 and H7 specific monoclonal antibodies were experimentally raised and used in the development of inhibition ELISAs for detection of serological response specifically directed against AIV subtypes H5 and H7. The ELISAs were evaluated with polyclonal chicken anti-AIV antibodies against AIV subtypes: H1N2, H5N2, H5N7, H7N1, H7N7, H9N9, H10N4 and H16N3.

Results

Both the H5 and H7 ELISA proved to have a high sensitivity and specificity and the ELISAs detected H5 and H7 antibodies earlier during experimental infection than the HI test did. The reproducibility of the ELISA’s performed at different times was high with Pearson correlation coefficients of 0.96-0.98.

Conclusions

The ELISAs are a potential alternative to the HI test for screening of large amounts of avian sera, although only experimental sera were tested in this study.
  相似文献   

8.
A peptide-based indirect ELISA to detect cattle antibodies against Fasciola hepatica was developed and evaluated for its sensitivity and specificity. An immunogenic antigen released in vitro by F. hepatica was purified. After purification the sequence of the first 20 N-terminal aa of this protein showed considerable homology with cathepsin L-like proteinase. Based on its homology with cathepsin-L1, we further focused on this protein for diagnostic purpose. Predicted B-cell epitopes of cathepsin-L1 were synthesised as single synthetic peptides and tested with respect to their diagnostic potential. An indirect ELISA based on one of these peptides was (i) evaluated further and (ii) compared to the potential of an indirect ELISA with excretion/secretion antigens from adult F. hepatica, or (iii) purified cathepsin-L1. Specificity and sensitivity of the three ELISAs were assessed using sera from calves experimentally infected with pure isolates of Dictyocaulus viviparus, Ostertagia ostertagi, Cooperia oncophora, Nematodirus helvetianus, Schistosoma mattheei, Ascaris suum, Taenia saginata or F. hepatica, respectively, and sera from parasite-naive calves. In addition, sera were analysed from calves naturally infected with F. hepatica. The sensitivities of all three ELISAs were also very high, 98.9% (i), 100% (ii) and 100% (iii). The specificity of the peptide ELISA was very high, 99.8%, whereas specificities of the ES antigens and cathepsin-L1 ELISAs were only 82.8% and 94.6%. In experimentally infected cattle, F. hepatica-specific antibodies were first detected between days 21 and 28 p.i. with all three ELISAs, and the antibody levels persisted in the peptide ELISA until day 183 p.i. All sera from naturally infected calves were positive in the peptide ELISA. These results demonstrate that the peptide-based F. hepatica ELISA is a useful method for detecting antibodies in the sera from cattle infected with F. hepatica. This type of immunodiagnostic will therefore contribute to more accurate diagnosis and to timely curative treatment of animals.  相似文献   

9.
Indirect enzyme-linked immunosorbent assays (ELISAs) based on recombinant MSP1a and MSP2 from a Brazilian isolate of Anaplasma marginale were developed to detect antibodies against this rickettsia in cattle. The high sensitivities (99% for both tests) and specificities (100% for both tests) were confirmed with sera from cattle positive or negative for A. marginale antibodies, respectively, by immunofluorescent antibody test. By the analysis of 583 sera from cattle of three regions of the state of Pernambuco, Brazil, the agreement between both tests was high, with a kappa index of 0.89. The similar performances of the ELISAs suggest that both tests can be used in epidemiological surveys for detection of antibodies to A. marginale in cattle.  相似文献   

10.
Full-length nucleoproteins from Ebola and Marburg viruses were expressed as His-tagged recombinant proteins in Escherichia coli and nucleoprotein-based enzyme-linked immunosorbent assays(ELISAs) were established for the detection of antibodies specific to Ebola and Marburg viruses. The ELISAs were evaluated by testing antisera collected from rabbit immunized with Ebola and Marburg virus nucleoproteins. Although little cross-reactivity of antibodies was observed in antiEbola virus nucleoprotein rabbit antisera, the highest reactions to immunoglobulin G(Ig G) were uniformly detected against the nucleoprotein antigens of homologous viruses. We further evaluated the ELISA's ability to detect antibodies to Ebola and Marburg viruses using human sera samples collected from individuals passing through the Guangdong port of entry. With a threshold set at the mean plus three standard deviations of average optical densities of sera tested, the ELISA systems using these two recombinant nucleoproteins have good sensitivity and specificity. These results demonstrate the usefulness of ELISA for diagnostics as well as ecological and serosurvey studies of Ebola and Marburg virus infection.  相似文献   

11.
Full-length nucleoproteins from Ebola and Marburg viruses were expressed as His-tagged recombinant proteins in Escherichia coli and nucleoprotein-based enzyme-linked immunosorbent assays (ELISAs) were established for the detection of antibodies specific to Ebola and Marburg viruses. The ELISAs were evaluated by testing antisera collected from rabbit immunized with Ebola and Marburg virus nucleoproteins. Although little cross-reactivity of antibodies was observed in anti-Ebola virus nucleoprotein rabbit antisera, the highest reactions to immunoglobulin G (IgG) were uniformly detected against the nucleoprotein antigens of homologous viruses. We further evaluated the ELISA’s ability to detect antibodies to Ebola and Marburg viruses using human sera samples collected from individuals passing through the Guangdong port of entry. With a threshold set at the mean plus three standard deviations of average optical densities of sera tested, the ELISA systems using these two recombinant nucleoproteins have good sensitivity and specificity. These results demonstrate the usefulness of ELISA for diagnostics as well as ecological and serosurvey studies of Ebola and Marburg virus infection.  相似文献   

12.
Rabbit antibodies against Encephalitozoon cuniculi were detected in an indirect microagglutination test using a bead substrate to which anti-rabbit immunoglobin G light and heavy chain antibodies were coupled. The test was positive using immune whole serum or F(ab)' and F(ab)'2 fragments of immunoglobin G but negative using the F(c) fragment. The reaction was blocked by saturating the beads with rabbit serum or by absorbing positive sera with excess Encephalitozoon cuniculi. The test provided a simple method to detect antibodies to Encephalitozoon cuniculi, did not require elaborate equipment and could be performed using frozen antigen.  相似文献   

13.
A simple, semi-automated immunofluorescence assay, (TRACK XI), was developed for the detection and quantitation of circulating antibodies to Sendai virus in mice. The assay was validated by selecting Sendai virus-free and naturally infected mice from six different colonies and testing each serum in both ELISA and quantitative immunofluorescence (QIF) assays. The QIF test utilizes Sendai viral proteins immobilized within a dried colloid gel and permits serum antibody quantitation in 30 minutes. Using a dedicated fluorometer, antibody titers in test sera are calculated automatically from a three-point best fit calibration line. The QIF test gave 92.9% agreement with the ELISA and proved to be a reproducible, accurate and convenient assay for the quantitative measurement of serum antibody to Sendai virus in mice.  相似文献   

14.
The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-infected persons could be symptomatic or asymptomatic. Asymptomatic and symptomatic patients can transmit SARS-CoV-2. This study aimed to study the humoral immune response in Saudis who are Covid-19 symptomatic and asymptomatic patients. We created three types of enzyme-linked immunosorbant assays (ELISAs) to reveal IgG and IgM antibodies (Abs) against SARS-CoV-2. The developed ELISAs were designed to detect Abs against SARS-CoV-2 N, S and N + S proteins. A number of Covid-19 symptomatic (1 5 3) and asymptomatic (84) RT–PCR-confirmed patient sera were used to evaluate the ELISAs and to determine the IgG and IgM antibody profile in those patients. The sensitivity and specificity of these ELISAs were evaluated using pre-Covid-19 pandemic serum samples. The results revealed the existence of anti-SARS-CoV-2 IgG and IgM Abs in Covid-19 symptomatic and asymptomatic Saudi persons. The use of SARS-CoV-2 N and S proteins in the same ELISA greatly increased the detectability of infection. In conclusion, the Covid-19 symptomatic and asymptomatic Saudi persons demonstrated both IgG and IgM antibody profile with higher titer in symptomatic patients. The use of N + S proteins as antibody capture antigens greatly increased the ELISA sensitivity.  相似文献   

15.
BACKGROUND: An increasing volume of data suggests a relationship between cytokine levels in human body fluids and disease pathogenesis. Traditionally, many individual assays would be performed to measure the large number of known cytokines and determine their associations with disease. A new technique for the simultaneous measurement of multiple cytokines in cell culture supernatants by fluorescent microsphere-based flow cytometry was adapted to human sera. METHODS: Multiplexed sandwich immunoassays for eight cytokines were developed by coupling cytokine-specific capture antibodies to beads with different emission spectra. The binding of biotinylated detection antibodies bound with a streptavidin-conjugated fluorochrome was analyzed. Recovery of "spiked" cytokines, sensitivity, and variability of the assays were evaluated. In addition, the results of the bead assays were compared with the results of commercial enzyme-linked immunosorbent assays (ELISAs) that used the same antibody pairs. RESULTS: Correlations of the bead assays and the ELISAs were 0.974 (n = 18) for supernatant samples and 0.859 (n = 28) for serum samples. High, false-positive values observed with some sera, assumed to be produced by heterophilic antibodies, were reduced by preincubation with a cocktail of animal sera. CONCLUSIONS: Fluorescent bead-based immunoassays can be used to quantitate multiple cytokines in human sera and contribute to an understanding of the role of cytokines in disease processes. This methodology is applicable to many combinations of purified analytes and high-affinity antibodies. Published 2001 Wiley-Liss, Inc.  相似文献   

16.
The effect of natural malaria transmission-blocking factors in the blood of Plasmodium falciparum gametocyte carriers was assessed in two types of functional bioassays. In the direct membrane feeding assay (DMFA), a comparison is made between the infectivity of gametocytes from a naturally infected gametocyte carrier in the presence of autologous plasma and the infectivity in the presence of replacement plasma from nonimmune donors. In the standard membrane feeder assay (SMFA), cultured NF54 gametocytes are used to measure the capacity of endemic sera to block transmission. In the DMFA, 18 out of 48 sera (37.5%) from Cameroonian gametocyte carriers reduced transmission significantly, while in the SMFA 22 out of 48 sera (45.8%) produced transmission reduction. There was a positive correlation between both assays (r + 0.41, P < 0.05). Antibodies against epitopes of transmission-blocking target antigens Pfs48/45 and Pfs230 were measured in competition ELISAs and compared with the results of DMFA and SMFA. Serological reactivity in competition ELISAs against three epitopes of Pfs48/45 was significantly higher in the group of transmission-reducing sera in both the DMFA and the SMFA, especially for epitope III. No significant difference was found for Pfs230 antibodies (epitope I). Sensitivity of the serological assays was approximately 60%, with a specificity of around 70%. Serological tests cannot replace the functional bioassay in field situations as yet, but can contribute in the selection of sera for SMFA evaluation.  相似文献   

17.
Sera from the majority of individuals that were positive in an enzyme-linked immunosorbent assay (ELISA) retrovirus (ARV), an isolate of the for antibodies to acquired immune deficiency syndrome (AIDS)-associated retrovirus (ARV), an isolate of the retrovirus identified as the etiologic agent of AIDS, were found to react with a 31,000-dalton protein (p31) in virus Western blot assays. To determine if this 31,000-dalton immunoreactive species originated from the putative endonuclease region of the polymerase (pol) gene of ARV, we cloned this portion of pol into bacterial expression vectors for direct expression and for expression as a fusion protein with human superoxide dismutase. Transformants from both constructions expressed immunoreactive protein detected in immunoblots with an AIDS patient's serum. Extracts from transformants expressing these sequences competed with the binding of antibodies from AIDS patients' sera to the 31,000-dalton protein in virus immunoblots, confirming that viral p31 originated from the endonuclease domain of the ARV polymerase gene. The superoxide dismutase-p31 fusion protein was purified, and an ELISA for detecting antibodies to p31 was developed. The majority (95%) of serum samples obtained from individuals seropositive in the virus ELISA were also positive in the p31 antibody ELISA.  相似文献   

18.
In order to investigate the IgG HIV-1 antibodies reactivity to structural components of the virus, 85 sera from infected Brazilians, comprising the total spectrum of HIV infection, were analysed by Western blot assay. The sera were confirmed as being positive to HIV with enzyme linked immuno assay (ELISA) and indirect immunofluorescence (IIF). Although the sera from patients reacted less intensively to the gag polypeptide of 55 KDa, no distinctive antigen reaction patterns were observed between sera patients with different clinical forms. Because of the higher frequency of reactivity to the gag p24 in AIDS patients, the patterns of anti-HIV IgG responses are similar to those observed in their African counterparts.  相似文献   

19.
Phage libraries displaying cDNA or random peptides have been used for profiling autoantibodies in cancer. The detection of autoantibodies in human sera using phages displaying specific epitopes is usually performed by phage-immobilized ELISAs which can detect specific antibodies without identification of whole antigens. However, these ELISAs can give feeble detection signals that are indistinguishable from background signals which are caused by human sera. To improve the usefulness of phage ELISA for human sera, the conditions for each step in phage ELISA were optimized. The antigenicity of phage antigens was maximal when using coating buffer of neutral pH. By using protein-free blocking buffer and pre-adsorbing human sera with phage host cell ER2738 extracts significantly decreased non-specific signals. Finally, when these conditions were applied to phage ELISA using K10P1, the values of the negative controls were concentrated near cutoff values, which made the assay more reliable. The optimized phage ELISA conditions described here would increase the efficacy of detection specific autoantibodies in human sera.  相似文献   

20.
Crimean-Congo Hemorrhagic Fever Virus (CCHFV) is a geographically widespread tick-borne arbovirus that has been recognized by the WHO as an emerging pathogen needing urgent attention to ensure preparedness for potential outbreaks. Therefore, availability of accurate diagnostic tools for identification of acute cases is necessary.A panel comprising 121 sequential serum samples collected during acute, convalescent and subsided phase of PCR-proven CCHFV infection from 16 Kosovar patients was used to assess sensitivity. Serum samples from 60 healthy Kosovar blood donors were used to assess specificity. All samples were tested with two IgM/IgG immunofluorescence assays (IFA) from BNITM, the CCHFV Mosaic 2 IgG and IgM indirect immunofluorescence tests (IIFT) from EUROIMMUN, two BlackBox ELISAs for the detection of CCHFV-specific IgM and IgG antibodies (BNITM), two Anti-CCHFV ELISAs IgM and IgG from EUROIMMUN using recombinant structural proteins of CCHFV antigens, and two ELISAs from Vector-Best (IgM: μ-capture ELISA, IgG: indirect ELISA using immobilized CCHFV antigen). Diagnostic performances were compared between methods using sensitivity, specificity, concordance and degree of agreement with particular focus on the phase of the infection.In early and convalescent phases of infection, the sensitivities for detecting specific IgG antibodies differed for the ELISA test. The BlackBox IgG ELISA yielded the highest, followed by the EUROIMMUN IgG ELISA and finally the VectorBest IgG ELISA with the lowest sensitivities. In the subsided phase, the VectorBest IgM ELISA detected a high rate of samples that were positive for anti-CCHFV IgM antibodies. Both test systems based on immunofluorescence showed an identical sensitivity for detection of anti-CCHFV IgM antibodies in acute and convalescent phases of infection.Available serological test systems detect anti-CCHFV IgM and IgG antibodies accurately, but their diagnostic performances vary with respect to the phase of the infection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号