首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Mass spectrometry-based proteomics has greatly benefitted from enormous advances in high resolution instrumentation in recent years. In particular, the combination of a linear ion trap with the Orbitrap analyzer has proven to be a popular instrument configuration. Complementing this hybrid trap-trap instrument, as well as the standalone Orbitrap analyzer termed Exactive, we here present coupling of a quadrupole mass filter to an Orbitrap analyzer. This "Q Exactive" instrument features high ion currents because of an S-lens, and fast high-energy collision-induced dissociation peptide fragmentation because of parallel filling and detection modes. The image current from the detector is processed by an "enhanced Fourier Transformation" algorithm, doubling mass spectrometric resolution. Together with almost instantaneous isolation and fragmentation, the instrument achieves overall cycle times of 1 s for a top 10 higher energy collisional dissociation method. More than 2500 proteins can be identified in standard 90-min gradients of tryptic digests of mammalian cell lysate- a significant improvement over previous Orbitrap mass spectrometers. Furthermore, the quadrupole Orbitrap analyzer combination enables multiplexed operation at the MS and tandem MS levels. This is demonstrated in a multiplexed single ion monitoring mode, in which the quadrupole rapidly switches among different narrow mass ranges that are analyzed in a single composite MS spectrum. Similarly, the quadrupole allows fragmentation of different precursor masses in rapid succession, followed by joint analysis of the higher energy collisional dissociation fragment ions in the Orbitrap analyzer. High performance in a robust benchtop format together with the ability to perform complex multiplexed scan modes make the Q Exactive an exciting new instrument for the proteomics and general analytical communities.  相似文献   

2.
Xylo-oligosaccharides with degrees of polymerisation 5-13, formed by partial acid hydrolysis from an extract representative of olive pulp glucuronoxylans (GX), were analysed by electrospray ionisation mass spectrometry (ESI-MS), both in positive and negative modes. The positive spectrum showed the presence of xylo-oligosaccharides in the mass range between m/z 500 and 1500 corresponding to singly [M+Na](+) charged ions of neutral (Xyl(7-9)) and acidic xylo-oligosaccharides (Xyl(5-9)MeGlcA), and doubly [M+2Na](2+) charged ions of Xyl(9-13) and Xyl(7-11)MeGlcA. Ammonium adducts [M+NH(4)](+) were also observed for Xyl(5-9)MeGlcA. The negative spectra showed the contribution of ions in the mass range between m/z 600 and 1400, ascribed to the deprotonated molecules [M-H](-) of Xyl(3-9)MeGlcA. Tandem mass spectrometry (MS/MS) of the major ions observed in the MS spectra was performed. The MS/MS spectra of the [M+Na](+) adducts showed the loss of MeGlcA residues as the major fragmentation pathway and glycosidic fragment ions of Xyl(n) and Xyl(n)MeGlcA structures. The MS/MS spectra of the [M+NH(4)](+) adducts suggests the occurrence of isomers of Xyl(5-9)MeGlcA oligosaccharides with the MeGlcA residue at the reducing end and at the non-reducing end of the molecules, although other structural isomers can also occur. Both glycosidic bond and cross-ring cleavages in the MS/MS spectra of the [M-H](-) ion suggest the occurrence of Xyl(3-9)MeGlcA with the substituting group at the reducing end position of the xylose backbone, as the main fragmentation ions. The results obtained by ESI-MS/MS, both in positive and negative modes, of Xyl(7-13)- and Xyl(5-11)MeGlcA, allow to identify fragmentation patterns of the structural isomers with MeGlcA linked to the terminal xylosyl residues of the oligosaccharides. The occurrence of these higher molecular weight oligosaccharides with a low substitution pattern allows to infer a scatter and random distribution of MeGlcA along the xylan backbone of olive pulp.  相似文献   

3.
We report the first application of electrospray ionisation mass spectrometry (ESI-MS) for the reproducible characterisation of strains of intact Gram-negative and Gram-positive bacteria. Electrospray ionisation was performed in both the positive and negative ion modes and the spectra obtained from Escherichia coli and Bacillus cereus were very information rich. Several of the observed negative mass ion fragments from E. coli could be assigned to specific fragmentation from bacterial phospholipids.Cluster analyses of these spectra showed that ESI-MS could be used to discriminate between these microorganisms to below species level. Therefore we conclude that ESI-MS constitutes a powerful approach to the characterisation and speciation of intact microorganisms.  相似文献   

4.
A method for the simultaneous determination of sulfadiazine and trimethoprim in plasma from Beagle dogs was developed and validated. Samples were deproteinized with acetonitrile and extracted with ethyl acetate. Sulfachloropyridazine and ormethoprim were used as internal standards for the sulfadiazine and trimethoprim analysis, respectively. The chromatography was carried out both on an LC-UV (liquid chromatography-ultraviolet detection) and ion-trap LC-MS(n) (liquid chromatography-mass spectrometric detection) instrument, operating in the positive APCI mode (atmospheric pressure chemical ionization). The purpose of this work was to compare the quantification results of both methods. Both the LC-UV and LC-MS-MS methods were validated for their linearity, accuracy, precision, limit of detection and limit of quantification, according to the requirements defined by the European Community. Calibration curves using plasma fortified between 0.1 and 1 microg/ml of sulfadiazine, 0.1 and 2 microg/ml of trimethoprim, 1 and 20 microg/ml of sulfadiazine showed a good linear correlation (r> or =0.9990, goodness-of-fit< or =8.4%). The results for the accuracy and precision at 1 microg/ml of sulfadiazine and trimethoprim and at 20 microg/ml of sulfadiazine fell within the ranges specified. The limits of quantification of both methods were 0.1 microg/ml. The limits of detection were 0.019 microg/ml of sulfadiazine and 0.024 microg/ml of trimethoprim for the LC-UV method, and 0.020 microg/ml of sulfadiazine and 0.062 microg/ml of trimethoprim for the LC-MS-MS method. The methods have been successfully applied in a pharmacokinetic study to determine the drug concentrations in plasma samples from dogs. A good correlation between the results of both methods was observed (R=0.9724, slope=1.0239, intercept=-0.2080 microg/ml for sulfadiazine and R=0.9357, slope=1.0433, intercept=0.0325 microg/ml for trimethoprim). The precision of both methods was also tested on the results of the same samples using an F-test (alpha=0.05), indicating that both methods did not differ in precision.  相似文献   

5.
Product ion mass spectral data of [M + H]+ ions of oligosaccharides, mainly tetra- and pentasaccharides, as their dipalmitoyl phosphatidylethanolamine derivatives were obtained using both liquid secondary ion mass spectrometry with B/E linked scanning and fast atom bombardment ionization with collision-induced dissociation/tandem mass spectrometry. Both methods give similar positive product ion spectra of equivalent high sensitivity (detection limits of approximately 50 pmol) that principally contain glycosidic cleavage ions retaining the reducing end of the molecule from which monosaccharide sequence can be deduced. A series of ions from fission of the phosphate ester bond together with glycosidic cleavage are present in the tandem mass spectra and B/E linked scan spectra when helium collision gas is used. Monosaccharide linkage position of isomeric molecules is reflected in the intensity of glycosidic fragmentation, without retention of the oxygen atom, with decreasing cleavage in the order 1-3 greater than 1-4 greater than 1-6 linkage. Fucose and N-acetylhexosamines show an increased degree of fragmentation over hexose sugars. The application of product ion spectra of derivatized oligosaccharides is demonstrated for characterizing mixed samples and also the acquisition of spectra directly from the silica surface of high-performance thin-layer chromatography plates.  相似文献   

6.
In proteomics, selected reaction monitoring (SRM) is rapidly gaining importance for targeted protein quantification. The triple quadrupole mass analyzers used in SRM assays allow for levels of specificity and sensitivity hard to accomplish by more standard shotgun proteomics experiments. Often, an SRM assay is built by in silico prediction of transitions and/or extraction of peptide precursor and fragment ions from a spectral library. Spectral libraries are typically generated from nonideal ion trap based shotgun proteomics experiments or synthetic peptide libraries, consuming considerable time and effort. Here, we investigate the usability of beam type CID (or "higher energy CID" (HCD)) peptide fragmentation spectra, as acquired using an Orbitrap Velos, to facilitate SRM assay development. Therefore, peptide fragmentation spectra, obtained by ion-trap CID, triple-quadrupole CID (QqQ-CID) and Orbitrap HCD, originating from digested cellular lysates, were compared. Spectral comparison and a dedicated correlation algorithm indicated significantly higher similarity between QqQ-CID and HCD fragmentation spectra than between QqQ-CID and ion trap-CID spectra. SRM transitions generated using a constructed HCD spectral library increased SRM assay sensitivity up to 2-fold, when compared to the use of a library created from more conventionally used ion trap-CID spectra, showing that HCD spectra can assist SRM assay development.  相似文献   

7.
A database independent search algorithm for the detection of phosphopeptides is described. The program interrogates the tandem mass spectra of LC-MS/MS data sets regarding the presence of phosphorylation specific signatures. To achieve maximum informational content, the complementary fragmentation techniques electron capture dissociation (ECD) and collisionally activated dissociation (CAD) are used independently for peptide fragmentation. Several criteria characteristic for peptides phosphorylated on either serine or threonine residues were evaluated. The final algorithm searches for product ions generated by either the neutral loss of phosphoric acid or the combined neutral loss of phosphoric acid and water. Various peptide mixtures were used to evaluate the program. False positive results were not observed because the program utilizes the parts-per-million mass accuracy of Fourier transform ion cyclotron resonance mass spectrometry. Additionally, false negative results were not generated owing to the high sensitivity of the chosen criteria. The limitations of database dependent data interpretation tools are discussed and the potential of the novel algorithm to overcome these limitations is illustrated.  相似文献   

8.
The field of proteomics continues to be driven by improvements in analytical technology, notably in peptide separation, quantitative MS, and informatics. In this study, we have characterized a hybrid linear ion trap high field Orbitrap mass spectrometer (Orbitrap Elite) for proteomic applications. The very high resolution available on this instrument allows 95% of all peptide masses to be measured with sub‐ppm accuracy that in turn improves protein identification by database searching. We further confirm again that mass accuracy in tandem mass spectra is a valuable parameter for improving the success of protein identification. The new CID rapid scan type of the Orbitrap Elite achieves similar performance as higher energy collision induced dissociation fragmentation and both allow the identification of hundreds of proteins from as little as 0.1 ng of protein digest on column. The new instrument outperforms its predecessor the Orbitrap Velos by a considerable margin on each metric assessed that makes it a valuable and versatile tool for MS‐based proteomics.  相似文献   

9.
A study of liquid chromatography-triple quadrupole mass spectrometry (LC-MS-MS) with positive electrospray ionisation (ESI) for the determination of selected drugs in human tissues and body fluids such as blood, urine and hair is described. The possibility to screen for and quantify the 19 most commonly prescribed neuroleptics on the Swedish market and determine the presence of their major metabolites within a single LC-MS-MS analysis was evaluated on a PE Sciex API2000 instrument. Chromatographic conditions were optimised and the best separation, with individual retention times for most of the analytes, was obtained on a Zorbax SB-CN column within a 9-min gradient run. The MS-MS fragmentation conditions were optimised for each compound in order to obtain both specific fragments and high signal intensity. Since neuroleptics are a heterogeneous group of compounds, a markedly difference in collision energy needed to achieve fragments of the selected parent ions was seen and the number of fragments achieved varied as well. For sensitive quantification the transition of the most intense fragment of the protonated molecular ion (M+1)(+) was selected for multiple reaction monitoring analysis. More than 70 transitions were finally included in the assay. Detection levels down to the lower ng/ml level were achieved for all analytes, but between analytes more than a 10-fold difference in signal response was seen. By evaluation of extracted ion chromatograms from the analysis of authentic human blood, urine and hair sample the proposed concept for rational drug analysis was found to be both selective and sensitive for the neuroleptics included. A great number of metabolites could be determined in blood, urine and hair as well. A full method validation was not performed since the objective was to evaluate the method design rather than to validate a final method set-up.  相似文献   

10.
Shotgun proteomics yields tandem mass spectra of peptides that can be identified by database search algorithms. When only a few observed peptides suggest the presence of a protein, establishing the accuracy of the peptide identifications is necessary for accepting or rejecting the protein identification. In this protocol, we describe the properties of peptide identifications that can differentiate legitimately identified peptides from spurious ones. The chemistry of fragmentation, as embodied in the 'mobile proton' and 'pathways in competition' models, informs the process of confirming or rejecting each spectral match. Examples of ion-trap and tandem time-of-flight (TOF/TOF) mass spectra illustrate these principles of fragmentation.  相似文献   

11.
Epoxidation of unsaturated pure triacylglycerols (TAGs), cholesterol, and phytosterols was investigated using air and 18O2 oxidation experiments. Oxidized lipids were analyzed using both triple quadrupole mass spectrometry (MS), ion-trap MS in the direct infusion mode, and triple quadrupole MS in tandem with a liquid chromatograph (LC-MS/MS). Pure 1,2-distearoyl-3-oleoyl-glycerol (SSO) samples were heated in sealed vials under air or 18O2 atmosphere at 160 degrees C for 1 h. LC-MS/MS analysis of 18O-labeled oxidized TAGs revealed that hydroperoxides and epoxide TAGs are formed mainly during this first step. Then, oxidized TAGs were incubated under an inert atmosphere, separately with 1,2-dipalmitoyl-3-oleoyl-glycerol (PPO) at 160 degrees C for 90 min, and with cholesterol and stigmasterol at 100 degrees C for 10 min. Subsequent LC-MS/MS analysis revealed the occurrence of epoxidation products of PPO, cholesterol, and sitosterol. Therefore, we showed the epoxidation of unsaturated lipids proceeds readily in contact with hydroperoxide TAGs, in the absence of molecular oxygen. Dual oxidation experiments using both air and 18O2 allowed investigation of oxygen atom transfer during epoxidation of lipids. Moreover, the experimental oxidation design presented can be used to study fragmentation pathways, as illustrated for 5,6-epoxycholesterol (CE) on both triple quadrupole and ion-trap MS. We report for the first time the occurrence of 5,6;22,23-diepoxystigmasterol (StDE) and 5,6;22,23-diepoxybrassicasterol (BDE) in autoxidized vegetable oils. Additionally, acid-catalyzed hydrolysis of epoxidized lipids, with emphasis on phytosterol polyol formation, was investigated using a model gastric medium. For confirmation, almost all identified products were synthesized and characterized by MS.  相似文献   

12.
We have developed a new and sensitive LC-MS platform, Extended Range Proteomic Analysis (ERPA), which is able to achieve very high sequence coverage and comprehensive characterization of post-translational modifications in complex proteins. This new platform provides advantages of both the top-down and bottom-up proteomic approaches by combining (i) digestion of the protein with an enzyme, such as Lys-C, which cuts less frequently than trypsin, leading to on average a higher molecular weight peptide size, (ii) high-performance LC separation of the resulting fragments, (iii) a new data acquisition strategy using the LTQ-FTMS, a hybrid mass spectrometer that couples a linear ion trap with a Fourier transform ion cyclotron resonance (FTICR) cell, for analysis of peptides in the range of 0.5 to 10 kDa, and (iv) new data analysis methods for assigning large peptide structures and determining the site of attachment of post-translational modifications as well as structural features from the accurate precursor mass together with MS(2) and MS(3) fragmentations. The LC retention of the Lys-C fragments is increased, relative to a tryptic digest, due to the generally greater hydrophobicity of the larger peptides, a result that is particularly important for peptides containing hydrophilic modifications such as glycosylation and phosphorylation. Furthermore, additional positively charged arginine and lysine residues in the Lys-C fragments enhance the sensitivity of the post-translationally modified phospho- and glycopeptides by at least 10-fold relative to tryptic fragments. In typical operation, the FTICR cell provides a survey scan with the high mass resolution (> 100 000) and accurate mass (<2 ppm) to characterize the higher charge-state precursor ions of the larger peptides. In parallel, the linear ion trap provides MS(2) and MS(3) fragmentation spectra, with a scan speed sufficiently fast for on-line LC-MS. Together, these data provide multiple means to determine or enhance the confidence of assignment of large or complicated peptide. Using ERPA, we demonstrate >95% sequence coverage in the analysis of two heavily phosphorylated and glycosylated proteins, beta-casein at the 50 fmole level and the epidermal growth factor receptor (EGFR) at the 1 pmole level. In summary, the combination of digestion strategy, high-performance separation, and the hybrid LTQ-FTMS instrument enables comprehensive characterization of large proteins, including posttranslational modifications.  相似文献   

13.
The negative ion mass spectra (2-4 eV) of twenty free alpha-amino acids have been investigated and compared with the respective low voltage positive ion mass spectra (6-16 eV). The important fragmentation processes are discussed.  相似文献   

14.
Avermectin endectocides are used for the treatment of cattle against a variety of nematode and arthropod parasites, and consequently may appear in milk after normal or off-label use. The compounds abamectin, doramectin, and ivermectin, contain only C, H and O and may be expected to be detected by LC-MS in negative ion mode. The others contain nitrogen in addition and would be expected to be preferentially ionized in positive mode. The use of positive ion and negative ion methods with electrospray LC-MS-MS were compared. Using negative ion the compounds abamectin, doramectin, ivermectin, emamectin, eprinomectin, and moxidectin gave a curvilinear response and were quantified in raw milk by LC-MS-MS with a triethylamine-acetonitrile buffer over the concentration range 1-60 ppb (microg/kg) using selamectin as the internal standard. The limits of detection (LOD) were between 0.19 ppb (doramectin) and 0.38 ppb (emamectin). The compounds gave maximum sensitivity with positive ionisation from a formic acid-ammonium formate-acetonitrile buffer and were detected in milk (LC-MS-MS) also with a curvilinear response over the range 0.5-60 ppb. Although the positive ion signals were larger, with somewhat lower limits of detection (LOD between 0.06 ppb (doramectin) and 0.32 ppb (moxidectin) the negative ion procedure gave a more linear response and more consistent results. Comparison of spiked samples in the range 2-50 ppb showed a high degree of correlation between the two methods.  相似文献   

15.
The possibility of mass spectrometric sequencing of peptides without the need for the conventional MS/MS analysis has been demonstrated experimentally. The peptide hydrolysate was fractionated by reversephase chromatography on a microbore column. The eluate fraction was injected into the mass spectrometer via an electrospray ion source that directly coupled a liquid chromatography instrument to a time-of-flight mass spectrometer (HPLC-MS). Fragmentation of the peptides eluted from the column was performed in the mass spectrometer interface by varying the voltage difference between the mass spectrometer nozzle and skimmer. A restricted set of intensive peaks of y-ions, which corresponded to sequential cleavage of all amino acids from the peptide, was obtained. The ratios of the y-ion peak intensities to the background were (5?100)/1. The presence of Lys and Arg in the peptides provided for a substantial increase of informative peak intensity in the mass spectra. The mass spectra of short peptides (up to 10 residues) were processed manually, whereas the Proteos hardware and software system was used to process the fragmentation results for a long N-terminal peptide of the human hemoglobin α-chain.  相似文献   

16.
Tandem mass spectrometry (MS/MS) is frequently used in the identification of peptides and proteins. Typical proteomic experiments rely on algorithms such as SEQUEST and MASCOT to compare thousands of tandem mass spectra against the theoretical fragment ion spectra of peptides in a database. The probabilities that these spectrum-to-sequence assignments are correct can be determined by statistical software such as PeptideProphet or through estimations based on reverse or decoy databases. However, many of the software applications that assign probabilities for MS/MS spectra to sequence matches were developed using training data sets from 3D ion-trap mass spectrometers. Given the variety of types of mass spectrometers that have become commercially available over the last 5 years, we sought to generate a data set of reference data covering multiple instrumentation platforms to facilitate both the refinement of existing computational approaches and the development of novel software tools. We analyzed the proteolytic peptides in a mixture of tryptic digests of 18 proteins, named the "ISB standard protein mix", using 8 different mass spectrometers. These include linear and 3D ion traps, two quadrupole time-of-flight platforms (qq-TOF), and two MALDI-TOF-TOF platforms. The resulting data set, which has been named the Standard Protein Mix Database, consists of over 1.1 million spectra in 150+ replicate runs on the mass spectrometers. The data were inspected for quality of separation and searched using SEQUEST. All data, including the native raw instrument and mzXML formats and the PeptideProphet validated peptide assignments, are available at http://regis-web.systemsbiology.net/PublicDatasets/.  相似文献   

17.
Researchers have several options when designing proteomics experiments. Primary among these are choices of experimental method, instrumentation and spectral interpretation software. To evaluate these choices on a proteome scale, we compared triplicate measurements of the yeast proteome by liquid chromatography tandem mass spectrometry (LC-MS/MS) using linear ion trap (LTQ) and hybrid quadrupole time-of-flight (QqTOF; QSTAR) mass spectrometers. Acquired MS/MS spectra were interpreted with Mascot and SEQUEST algorithms with and without the requirement that all returned peptides be tryptic. Using a composite target decoy database strategy, we selected scoring criteria yielding 1% estimated false positive identifications at maximum sensitivity for all data sets, allowing reasonable comparisons between them. These comparisons indicate that Mascot and SEQUEST yield similar results for LTQ-acquired spectra but less so for QSTAR spectra. Furthermore, low reproducibility between replicate data acquisitions made on one or both instrument platforms can be exploited to increase sensitivity and confidence in large-scale protein identifications.  相似文献   

18.
Twelve naturally occurring glucosinolates displaying alkenyl, hydroxylated, methylsulphinyl, aromatic and indole side chains were investigated by both negative and positive ion electrospray ionisation-tandem mass spectrometry (ESI-MS/MS). In order to resolve the MS/MS spectra obtained from the anion and cation molecular ions of glucosinolates, the different fragments were investigated by MSn experiments using an ion trap spectrometer. The MS3 spectra obtained permitted possible fragmentation schemes to be proposed. These were supported by accurate mass measurements of some characteristic diagnostic ions with the help of a quadrupole time-of-flight instrument. The negative ion ESI-MS/MS behaviour of the different glucosinolates investigated in this study confirmed previously described patterns and revealed new interesting structural informative fragments. Some are common to all the glucosinolates and others are highly specific for a type of variable side chain. The positive ion ESI-MS/MS fragments obtained from the [MNa+Na]+ or [MK+K]+ molecular ions did not provide complementary specific diagnostic ions. Nevertheless, when compared with the negative ion mode, the daughter ions appeared more homogenous and with a better relative abundance for all of the 12 compounds studied. Moreover, the positive ion mode appeared to be more efficient than the negative mode for the study of methoxylated glucosinolates and should be useful to detect the glucosinolates present as organic salts in crude plant extracts.  相似文献   

19.
Mass spectrometric fragmentation patterns of herbacetin 3-O-glucopyranoside-8-O-glucuronopyranoside (1), gossypetin 3-O-glucopyranoside-8-O-glucuronopyranoside (2) and takakin 7-O-glucopyranoside-8-O-glucuronopyranoside (3) were elucidated from mass spectra obtained with electrospray ionisation. The usefulness of the fragmentation patterns observed in the positive and negative mode for structural elucidation of the studied compounds is discussed. The fragmentation of 3 was substantially different from 1 and 2, especially in the negative mode. In order to explain these differences, theoretical calculations were performed.  相似文献   

20.
The microheterogeneous alamethicin F30 (ALM F30) isolated from the fermentation of Trichoderma viride strain NRRL 3199 was analyzed by nonaqueous capillary electrophoresis coupled to electrospray ion-trap mass spectrometry (ESI-IT-MS) and electrospray time-of-flight mass spectrometry (ESI-TOF-MS). Tandem ESI-IT-MS was used for elucidation of the amino acid sequence based on the fragmentation pattern of selected parent ions. The MS/MS spectra using the [M + 3H](3+) or [M + 2H](2+) ions as precursor ions displayed the respective b- and the y-type fragments resulting from cleavage of the particularly labile Aib-Pro bond. The MS(3) of these fragments generated the b acylium ion series, as well as internal fragment ion series. Eleven amino acid sequences were identified, characterized by the exchange of Ala to Aib in position 6, Gln to Glu in positions 7 or 19 as well as the loss of the C-terminal amino alcohol. In addition, two truncated pyroglutamyl peptaibols were found. Overall, seven new sequences are reported compared to earlier LC-MS studies. The composition of the components was confirmed by on-line ESI-TOF-MS detection. Mass accuracy well below 5 ppm was observed. Quantification of the individual components was achieved by a combination of UV and TOF-MS detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号