首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 671 毫秒
1.
A latex test was elaborated which served for evaluation of quality of rabbit immune sera for antigen 0 of selected Gram-negative bacteria. Sensitivity and specificity of this test in comparison with passive hemagglutination and immunoenzymatic DOT-ELISA reactions was evaluated. These studies were performed on immune sera for antigen O of Salmonella groups B, C1, C2, D and E, Yersinia pseudotuberculosis and in antigen preparations for above listed microorganisms both in homologous and heterologous systems. It was found that sensitivity of the latex test is 9 to 160 times lower than that of passive hemagglutination and 7 to 307 lower than for DOT-ELISA. Sensitivity of the latex test and passive hemagglutination reaction was evaluated on the basis of results of cross reaction between studied antigens and unabsorbed rabbit sera, establishing so called sensitivity indexes, which were informing how many times heterologous titer is lower than homologous titer. So evaluated sensitivity of the latex test was close to sensitivity of the passive hemagglutination reaction. It was found that slide latex test is characterized by satisfactory sensitivity and good sensitiveness and may be used for evaluation of antibody level 0 antigens of Salmonella and Yersinia. The value of this test is characterized by high repeatability of results, as well as low work and time-consuming.  相似文献   

2.
The authors have developed the optimum conditions for the preparation of antigenic diagnosticum based on latex manufactured in the USSR. To sensitize latex with the diameter of microspheres equal to 0.83 microns, Brucella polysaccharide was used in a dose of 100 micrograms/ml. As stabilizer, polyvinylpyrrolidone at a concentration of 0.1% was used. The specificity and sensitivity of the diagnosticum were studied in analysis of serum samples taken from 102 healthy donors and patients with infectious diseases of nonbrucellar etiology and from 120 patients with different forms of brucellosis. The specificity of the diagnosticum was found to be 94.1% and its sensitivity, 77.5%. Comparative study of the latex agglutination test with other serological tests showed that the former test is highly effective both in acute and chronic forms of the disease. A high degree of correlation between the agglutination test, Coombs' test, the passive hemagglutination test and the latex agglutination test was established (r = 0.83, 0.72 and 0.62, respectively).  相似文献   

3.
A rapid reversed passive latex agglutination method that uses high-density latex particles for the detection of staphylococcal enterotoxins (SE) A to E was developed. It took 3 h for incubation, much less than the 16 h needed with a customary latex agglutination test for SE detection such as a commercial test kit (SET-RPLA; Denka Seiken Co. Ltd., Tokyo, Japan). The rapid test was shown to be highly specific and sensitive for SE detection (detection limit, about 0.5 ng of SE per ml), comparable to the SET-RPLA test. The rapid test was also efficient in SE detection in foods and culture supernatants of staphylococcal strains, similar to the SET-RPLA test. This showed that a rapid test with high-density latex particles is fully reliable for use.  相似文献   

4.
A rapid reversed passive latex agglutination method that uses high-density latex particles for the detection of staphylococcal enterotoxins (SE) A to E was developed. It took 3 h for incubation, much less than the 16 h needed with a customary latex agglutination test for SE detection such as a commercial test kit (SET-RPLA; Denka Seiken Co. Ltd., Tokyo, Japan). The rapid test was shown to be highly specific and sensitive for SE detection (detection limit, about 0.5 ng of SE per ml), comparable to the SET-RPLA test. The rapid test was also efficient in SE detection in foods and culture supernatants of staphylococcal strains, similar to the SET-RPLA test. This showed that a rapid test with high-density latex particles is fully reliable for use.  相似文献   

5.
The ability of 135 Staphylococcus strains isolated from Spanish dry-cured hams to produce enterotoxins in culture was investigated by the reversed passive latex agglutination method. A high percentage of enterotoxigenic Staphylococcus aureus strains (85.9%) was recorded, and 54.3% of these produced enterotoxin A. One of the two Staphylococcus epidermidis strains produced enterotoxin C. The reversed passive latex agglutination method yielded satisfactory results.  相似文献   

6.
The ability of 135 Staphylococcus strains isolated from Spanish dry-cured hams to produce enterotoxins in culture was investigated by the reversed passive latex agglutination method. A high percentage of enterotoxigenic Staphylococcus aureus strains (85.9%) was recorded, and 54.3% of these produced enterotoxin A. One of the two Staphylococcus epidermidis strains produced enterotoxin C. The reversed passive latex agglutination method yielded satisfactory results.  相似文献   

7.
A reversed passive latex agglutination (RPLA) assay for detecting Clostridium difficile toxin A is presented. Purified monoclonal antibody (mAb 37B5) was used for latex sensitization. The culture supernatants of 93 strains of C. difficile were tested by RPLA assay and the results compared with those of a commercially available latex agglutination test, PCR and cytotoxin assay with Vero cells. There was agreement between RPLA, cytotoxicity and PCR assays, but 29 strains were positive in the RPLA assay while 35 were positive in the cytotoxicity test and PCR using primer pair NK3-NK2 directed to the nonrepeating portion of the C. difficile toxin A gene. The 6 cytotoxic but RPLA-negative strains were demonstrated to be toxin A-negative/toxin B-positive strains in the PCR assay by using primer pair NK11-NK9 directed to the repeating portion of the C. difficile toxin A gene. There were no cross-reactions with culture supernatants of the other clostridial strains except for two strains of C. sordelli that produced hemorrhagic toxin (which is immunologically related to C. difficile toxin A).  相似文献   

8.
One hundred and thirty one faecal specimens from cases of suspected Clostridium perfringens food poisoning were examined by both a reverse passive latex agglutination test and a standard ELISA test for the presence of Cl. perfringens enterotoxin. The latex agglutination test proved as sensitive and specific as the ELISA, and required less time at the bench without the need for specialized equipment.  相似文献   

9.
食品中金黄色葡萄球菌肠毒素的快速检测方法   总被引:4,自引:0,他引:4  
采用反向被动乳胶凝集法 (RPLA)和mini VIDAS (ELFA)两种方法对 42份金黄色葡萄球菌阳性样品进行了肠毒素检测。结果RPLA法的金葡菌肠毒素检出率为 61.9% (P<0.05 )要高于ELFA法的检出率 50.0% (P <0.05 ) ,但检测时间长 ( 20h)。在实验中我们还发现 ,血浆凝固酶阴性的葡萄球菌也可产生肠毒素 ,其原因有待进一步的研究。  相似文献   

10.
Four lots of the SET-RPLA kit (Denka Seiken Co. Ltd., Tokyo), a commercial reverse passive latex agglutination test kit for the detection of staphylococcal enterotoxins A, B, C, and D in foods, have been evaluated for their efficacy. The kits showed high specificity and sensitivity with a detection limit of 0.75 ng enterotoxin/g of food. The test is simple, is completed within 24 h, and does not require complicated extraction or concentration procedures nor expensive equipment. In addition, the assay is semiquantitative. However, as in any other immunological system, routine verification of the specificity of the latex reagents against standard enterotoxins and toxin-free food extracts is necessary.  相似文献   

11.
Human HBs antibody was isolated by affinity chromatography on HBs antigen absorbed to concanavalin A linked to Sepharose 4B. When a human anti-HBs immunoglobulin preparation obtained by Cohn's cold ethanol fractionation method was used as a starting material, the antibody was concentrated about 10 times in terms of the passive hemagglutination titer with a recovery rate higher than 50%. Latex particles coated with human anti-HBs antibody thus prepared were proved to be useful in detecting HBs antigen in human blood samples. In its sensitivity and in rapidity of its performance, the antibody-coated latex agglutination test seems to be superior to conventional immunodiffusion techniques.  相似文献   

12.
In vivo length-force relationship of canine diaphragm   总被引:4,自引:0,他引:4  
Diaphragmatic length was measured by sonomicrometry and transdiaphragmatic pressure (Pdi) by conventional latex balloons in eight dogs anesthetized with pentobarbital sodium under passive conditions and during supramaximal phrenic stimulation. The passive length-pressure relationship indicates that the crural part of the diaphragm is more compliant than the costal part. With supramaximal stimulation the costal diaphragm showed a length-pressure relationship similar in shape to in vitro length-tension curves previously described for the canine diaphragm. The crural part has a smaller pressure-length slope than the costal part in the length range from 80% of optimum muscle length (Lo) to Lo. At supine functional residual capacity (FRC) the resting length (LFRC) of the costal and crural diaphragms are not at Lo. The costal part is distended to 105% of Lo, and crural is shortened to 92% of Lo. Tidal shortening will increase the force output of costal while decreasing that of the crural diaphragm. The major forces setting the passive supine LFRC are the abdominal weight (pressure) and the elastic recoil of the lungs. The equilibrium length (resting length of excised diaphragmatic strips) was 79 +/- 3.6% LFRC for the costal diaphragm and 87 +/- 3.9% LFRC for the crural diaphragm. Similar shortening was obtained in the upright position, indicating passive diaphragmatic stretch at supine LFRC.  相似文献   

13.
This report describes a new immunological method for the detection and quantification of Nitrospira populations using the reverse passive latex agglutination (RPLA). The numbers of the genus Nitrospira have been quantified only by molecular biological techniques such as FISH and quantitative PCR to date. Using high-density latex particles and a specific polyclonal antibody, Nitrospira populations in the wastewater treatment process were quantified in the shortest 4 h of incubation. The minimum detectable number of Nitrospira cells was 7.0x10(5) (log(10) 5.85) cells/ml. It is thought that the RPLA method can quantify Nitrospira populations more simply, economically, and speedily than molecular biological techniques or the culture method, because this procedure has a simple protocol and does not require the use of specialized equipment, expensive reagents, or technical skill. Therefore it is applicable for use in the everyday control and maintenance of water quality in wastewater treatment facilities where equipment is not sufficient or in the field.  相似文献   

14.
We developed a conventional immunosensor for fibrinogen and fibrin degradation products (FDP) to combine a quartz crystal microbalance (QCM) with the agglutination reaction of immunized latex beads. FDP induced an immunoreaction due to anti-FDP antibody immobilized latex particles. We successfully measured FDP concentration of in human serum within 10 min by QCM method. The detection range of QCM immunosensor is covered with screening concentration of FDP in serum (<10 microg/ml of FDP). The time course of latex agglutination obtained from QCM immunosensor is synchronized to that of latex photometric immunoassay. SEM was used to observe the surface of QCM that applied FDP serum. The size of latex particles agglutinated on the QCM electrode increased concomitant with FDP concentration. Frequency shift on immunoreaction explains the increased adsorption amount of agglutinated latex on QCM.  相似文献   

15.
Intrinsic fluorescence of polystyrene dissolved in organic solvents such as 1,2-dimethoxyethane was used to develop a sensitive method for the quantification of polystyrene latex beads. This method allows the assay of latex in the microgram range and is one order of magnitude more sensitive than the conventional spectrophotometric method. The fluorometric technique was used in the quantification of phagocytic latex particle uptake by macrophages and in the quantification of isolated phagosomal fractions.  相似文献   

16.
Data on sensitization to latex as well as measures aimed at prevention and treatment of latex allergy, are presented. The intensity of the symptoms manifestation of latex allergy was shown to depend on the duration of contact with latex. To prevent the development of latex allergy, the following preparations were used: the antihistaminic preparation Claritine, the immunocorrecting preparations Ruzam and polycomponent vaccine VP-4. The use of Claritine was shown to lead to the alleviation of the symptoms of latex allergy, but after treatment with Claritine was stopped the symptoms of latex allergy reappeared. The clinical effect lasted for as long as 2 months after treatment with Ruzam, while in case of polycomponent vaccine VP-4 use remission was registered even 3 months later. The data presented thus confirm topicality of the latex allergy problem and practical importance of using the immunocorrecting preparations Ruzam and polycomponent vaccine VP-4 for its prevention and treatment.  相似文献   

17.
The radiotracer technique is described for transport and metabolic studies in latex producing bark. This technique provided further evidence that carbohydrates are supplied to latex vessels as sucrose and that sucrose is readily used for rubber synthesis. Bark treatment with ethylene resulting in latex flow stimulation is shown to activate within a few hours sucrose and water transport into the latex vessels. The available knowledge suggests an implication of an energy-dependent process of proton excretion which could explain the earlier observed ethylene induced alkalization of latex cytosol enhancing invertase and sucrose utilization. An increase of tapping intensity decreases the level of latex sucrose and changes its distribution pattern in drained bark. There is a clonal difference in the early response to exploitation. Bark excision by conventional tapping inhibits downward sucrose translocation, the inhibition being proportional to the surface of consumed bark above the tapping cut. Seasonal variation in the level of latex sucrose is related to variations in sunshine duration and sucrose concentration rises during the process of refoliation. The results stress the importance of sucrose supply to latex vessels for latex producing potentialities and indicate an association of low sucrose availability in latex vessels with premature latex vessel degeneration and bark dryness.  相似文献   

18.
Digestion of staphylococcal enterotoxin by Bacillus natto   总被引:15,自引:0,他引:15  
Cooked rice contaminated with staphylococcal enterotoxin A (SEA) was mixed with 'natto', a Bacillus natto fermented soybean food, and the mixture was incubated at 37 °C for 1 h. Reversed passive latex agglutination (RPLA) tests performed on the mixture revealed that the RPLA titer against SEA was significantly reduced after incubation. Subsequent analytical tests showed that the SEA protein molecule was fragmented to small peptides by an extracellular protease, subtilisin, produced by B. natto. The proteolytic activity of B. natto was also found to be effective against ohter types of staphylococcal enterotoxins.  相似文献   

19.
Ligand-bearing liposomes are used to enhance the agglutination ‘signal’ of a typical latex assay for the detection of human rheumatoid factor. Heat-denatured IgG, the antigen to which rheumatoid factor binds naturally, was covalently attached to latex spheres. The liposomes were covalently coated with a ‘second ligand’ which also recognizes rheumatoid factor, anti-human IgM Fab′ fragments. In the present test configuration, rheumatoid factor present in a patient's serum binds to the IgG attached to the latex particles. The liposomes, in turn, bind rapidly to rheumatoid factor-sensitized latex, via the second ligand, promoting the formation of large, clearly visible latex aggregates. When latex spheres bearing the same type and density of second ligand were used to replace the liposomes they failed to improve agglutination, suggesting that multivalent presentation of the second ligand is not sufficient to insure the improvement. These results suggest that fluidity of the liposomal membrane is a requirement for the effect. Sensitivity as well as ‘readability’ are improved by the liposomes while specificity remains unaffected. The principle of using ligand-bearing liposomes to enhance particle agglutination is applicable to a wide range of other diagnostic assays.  相似文献   

20.
The latex agglutination test has been applied as a detection system for lectins, the method being especially useful in locations where the dependence on blood for hemagglutination tests could be minimised. The binding of various glycoproteins and sugars individually to the latex particles facilitated the agglutination with lectins having varying sugar specificities. The glycoproteins used were ovalbumin, horseradish peroxidase, porcine mucin and fetuin, while N-acetylglucosamine, N-acetylgalactosamine comprised the sugars used for binding to latex. The sensitivity of the latex agglutination tests was comparable with that of hemagglutination tests. Sugar binding specificity of the lectins could also be determined by inhibition of the agglutination in the presence of corresponding free sugars. The method proved to be useful in screening crude seed extracts for the presence of lectins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号