1.
Gold nanoparticles were used to enhance the immobilization amount and retain the immunoactivity of recombinant dust mite allergen Der f2 immobilized on a glassy carbon electrode (GCE). The interaction between allergen and antibody was studied by electrochemical impedance spectroscopy (EIS). Self-assembled Au colloid layer (?=16nm) deposited on (3-mercaptopropyl)trimethoxysilane (MPTS)-modified GCE offered a basis to control the immobilization of allergen Der f2. The impedance measurements were based on the charge transfer kinetics of the [Fe(CN)(6)](3-/4-) redox pair, compared with bare GCE, the immobilization of allergen Der f2 and the allergen-antibody interaction that occurred on the electrode surface altered the interfacial electron transfer resistance and thereby slowed down the charge transfer kinetics by reducing the active area of the electrode or by preventing the redox species in electrolyte solution from approaching the electrode. The interactions of allergen with various concentrations of monoclonal antibody were also monitored through the change of impedance response. The results showed that the electron transfer resistance increased with increasing concentrations of monoclonal antibody.  相似文献   

2.
Qu F  Lu H  Yang M  Deng C 《Biosensors & bioelectronics》2011,26(12):4810-4814
A new electrochemical immunosensor for the detection of protein biomarker platelet-derived growth factor BB (PDGF-BB) was developed based on graphene oxide (GO) initiated silver enhancement. The immunosensor was fabricated based on the traditional sandwich protocol using secondary anti-PDGF-BB antibody (Ab(2)) modified GO as label. Gold electrode was first modified with self-assembled monolayer (SAM) to block the electron transfer between the electrode and K(3)Fe(CN)(6) solution. After the immobilization of primary anti-PDGF-BB antibody (Ab(1)) onto electrode via aminidation to the carboxylic group of SAM and the formation of the sandwich immuno-structure onto electrode surface, the electrode was immersed into silver enhancement solution for silver deposition. The deposited metal silver onto GO then mediated electron transfer across the SAM, producing redox current. The resulting immunosensor displays a wide range of linear response, low detection limit, good reproducibility and stability. The immunosensor was used to the detection of PDGF-BB contents in serum samples with satisfactory results.  相似文献   

3.
Lu L  Liu B  Zhao Z  Ma C  Luo P  Liu C  Xie G 《Biosensors & bioelectronics》2012,33(1):216-221
A novel electrochemical immunoassay system for the detection of human epididymis-specific protein 4 (HE4) was developed. A chitosan-titanium carbide (TiC) nanocomposition film was first electrodeposited onto a tin-doped indium oxide (ITO) electrode at a constant potential. Gold (Au) nanoparticles were then electrodeposited on the surface of the chitosan-TiC film by cyclic voltammetry (CV). The capture antibody (anti-HE4) was adsorbed onto the Au and TiC nanoparticles. After a specific sandwich immunoreaction among the capture antibody, HE4, and biotinylated secondary antibody, biotinylated primer DNA was immobilized on the secondary antibody by biotin-streptavidin system. Appropriate amounts of circular template DNA and biotinylated primer DNA were used for rolling circle amplification (RCA) under optimal conditions. The RCA products provided a large number of sites to link DNA detection probes. Doxorubicin hydrochloride intercalated the CG-GC steps between the RCA products and the DNA detection probes, which was monitored by differential pulse voltammetry (DPV) based on the current signal of doxorubicin hydrochloride. With the above-mentioned amplification factors, the current responded to HE4 linearly in the concentration range of 3-300 pM under optimal detection conditions, with a detection limit of 0.06 pM. Stepwise changes in the microscopic features of the surfaces and electrochemical properties upon the formation of each layer were confirmed by scanning electron microscopy (SEM), atomic force microscopy (AFM), and electrochemical impedance spectroscopy (EIS). This system was successfully employed for the detection of HE4 with good accuracy and renewable ability.  相似文献   

4.
A highly stable functional composite film was prepared using polyazetidine prepolymer (PAP) with peroxidase from horseradish (HRP) and/or glucose oxidase (GOx). The good permeability of the PAP layer to classical electrochemical mediators, as evaluated by the determination of the diffusion coefficient of different redox molecules, is of great importance in view of the use of PAP as an immobilizing agent in second-generation biosensor development. Cyclic voltammetry of the HRP-PAP layer on a glassy carbon electrode (GCE) showed a pair of stable and quasi-reversible peaks for the HRP-Fe((III))/Fe((II)) redox couple at about -370 mV vs. Ag/AgCl electrode in pH 6.5 phosphate buffer. The electrochemical reaction of HRP entrapped in the PAP film exhibited a surface-controlled electrode process. This film and the successive modifications (HRP-PAP self-assembled monolayer (SAM) modified Au electrode) were used as a biological catalyst (hydrogen peroxide transducers) for glucose biosensors, after coupling to GOx. Both HRP/GOx-PAP and HRP/GOx-PAP SAM third generation biosensors were prepared and characterized. The use of PAP as immobilizing agent offers a biocompatible micro-environment for confining the enzyme and foreshadows the great potentiality of this immobilizing agent not only in theoretical studies on protein direct electron transfer but also from an applications point of view in the development of second- and third-generation biosensors.  相似文献   

5.
The demonstration of a labeless immunosensor for the detection of pathogenic bacteria using screen printed gold electrodes (SPGEs) and a potassium hexacyanoferrate(II) redox probe is reported. Gold electrodes were produced using screen printing and the gold surfaces were modified by a thiol based self assembled monolayer (SAM) to facilitate antibody immobilisation. SAMs based on the use of thioctic acid (TA), mercaptopropionic acid (MPA) and mercaptoundecanoic acid (MUA) were evaluated. Following antibody immobilisation via the optimum SAM, the redox behaviour and diffusion co-efficient (D) of the potassium hexacyanoferrate(II) probe was monitored in the absence and presence of analyte. In the presence of analyte, a change in the apparent diffusion co-efficient of the redox probe was observed, attributable to impedance of the diffusion of redox electrons to the electrode surface due to the formation of the antibody-bacteria immunocomplex. No change in the diffusion co-efficient was observed when a non-specific antibody (mouse IgG) was immobilised and antigen added. The system has been demonstrated with Listeria monocytogenes and Bacillus cereus.  相似文献   

6.
《IRBM》2008,29(2-3):141-148
This study describes the grafting of red blood cells (RBC) onto a gold electrode. The erythrocytes were immobilised using antigen/antibody crosslinking based on the bonding of anti-D with the corresponding antigen of the RBC membrane that is shared by all erythrocytes from the positive rhesus group (O+). To optimise the reproducibility of the modified electrode and to avoid nonspecific interactions, the anti-D layer was deposited onto a protein G layer. The bridge between the protein G and the gold transducer was formed using mixed thiol-based self-assembled monolayer (SAM) (a mixture of 11-mercaptoundecanoic acid and 6-mercapto-1-hexanol in a 1/10 ratio). Each layer deposited was characterized, firstly, with a quartz crystal microbalance to obtain the deposited mass and the corresponding number of moles per square centimetres and secondly, by electrochemical impedance spectroscopy (EIS) using a redox couple Fe(CN)63−/4− (1:1) as an EIS probe. Subsequent modelling with appropriate circuitry enabled the values for each component representing the interface (electrode/film/solution) to be calculated at each step of the grafting process. From these results the surface coverage has been calculated to range from 95 to 98%.  相似文献   

7.
8.
Gold nanoparticles have been attached onto glassy carbon electrode surface through sulfhydryl-terminated monolayer and characterized by X-ray photoelectron spectroscopy, atomic force microscopy, electrochemical impedance spectroscopy and cyclic voltammetry. The gold nanoparticles-attached glassy carbon electrodes have been applied to the immobilization/adsorption of hemoglobin, with a monolayer surface coverage of about 2.1 x 10(-10) mol cm(-2), and consequently obtained the direct electrochemistry of hemoglobin. Gold nanoparticles, acting as a bridge of electron transfer, can greatly promote the direct electron transfer between hemoglobin and the modified glassy carbon electrode without the aid of any electron mediator. In phosphate buffer solution with pH 6.8, hemoglobin shows a pair of well-defined redox waves with formal potential (E0') of about -0.085 V (versus Ag/AgCl/saturated KCl). The immobilized hemoglobin maintained its biological activity, showing a surface controlled electrode process with the apparent heterogeneous electron transfer rate constant (ks) of 1.05 s(-1) and charge-transfer coefficient (a) of 0.46, and displays the features of a peroxidase in the electrocatalytic reduction of hydrogen peroxide. A potential application of the hemoglobin-immobilized gold nanoparticles modified glassy carbon electrode as a biosensor to monitor hydrogen peroxide has been investigated. The steady-state current response increases linearly with hydrogen peroxide concentration from 2.0 x 10(-6) to 2.4 x 10(-4) M. The detection limit (3sigma) for hydrogen peroxide is 9.1 x 10(-7) M.  相似文献   

9.
Anti-HER-3 antibody was used for the first time in a disposable immunosensor based on indium tin oxide (ITO) substrate for HER-3 quantification. Anti-HER-3 was immobilized onto ITO substrate by 3-aminopropyl)triethoxysilane (APTES) and glutaraldehyde. This highly sensitive immunosensor was capable of detecting concentrations of HER-3 down to the femtogram/ml level by investigating changes in the charge transfer resistance (Rct) using electrochemical impedance spectroscopy (EIS). Construction of ITO layers was carefully investigated using a broad range of techniques such as voltammetry, EIS, atomic force microscopy (AFM), and scanning electron microscopy (SEM). Meanwhile, in an immunosensor system, the “single frequency impedance” technique was first used for characterization of interaction between HER-3 and anti-HER-3. Eventually, the proposed ITO-based immunosensor was applied to artificial serum samples spiked with HER-3.  相似文献   

10.
This paper presents an electrochemical immune sensor for label free detection of epidermal growth factor receptor (EGFR) by immobilizing anti-EGFR antibody (Anti-EGFRab) on dithiobissuccinimidyl propionate (DTSP) self-assembled monolayer (SAM) on gold (Au) electrode. Electrochemical studies show that increased surface concentration of redox moieties onto Anti-EGFRab/DTSP immuno-electrode leads to high electron transport and improved sensing performance. The antigen-antibody complex demonstrates a high association constant (5×10(12)L/mol) that results in high affinity of Anti-EGFRab to EGFR, confirming that the DTSP-SAM provides a conducive environment for anti-EGFR immobilization. The electrochemical response of EA/Anti-EGFRab/DTSP/Au electrode as a function of EGFR concentrations exhibits a linear range from 1pg/mL to 100ng/mL, a detection limit of 1pg/mL at a sensitivity of 2.02μAM(-1)at a regression coefficient of 0.99.  相似文献   

11.
Electrochemistry of microperoxidase-11 (MPx-11) anchored on the mixed self-assembled monolayer (SAM) of 2-(2-mercaptoethylpyrazine) (PET) and 4,4'-dithiodibutyric acid (DTB) on gold (Au) electrode and the biosensing of uric acid (UA) is described. MPx-11 has been covalently anchored on the mixed SAM of PET and DTB on Au electrode. MPx-11 on the mixed self-assembly exhibits reversible redox response characteristic of a surface confined species. The heterocyclic ring of PET promotes the electron transfer between the electrode and the redox protein. The apparent standard rate constant kapps obtained for the redox reaction of MPx-11 on the mixed monolayer is approximately 2.15 times higher than that on the single monolayer of DTB modified electrode. MPx-11 efficiently mediates the electrocatalytic reduction of H2O2. MPx-11 electrode is highly sensitive to H2O2 and it shows linear response for a wide concentration range. The electrocatalytic activity of the MPx-11 electrode is combined with the enzymatic activity of uricase (UOx) to fabricate uric acid biosensor. The bienzyme assembly is highly sensitive towards UA and it could detect UA as low as 2 microM at the potential of -0.1 V. The biosensor shows linear response with a sensitivity of 3.4+/-0.08 nA cm(-2) microM(-1). Ascorbate (AA) and paracetamol (PA) do not significantly interfere in the amperometric sensing of UA.  相似文献   

12.
An electrochemical impedimetric immunosensor was developed for ultrasensitive determination of insulin-like growth factor-1 (IGF-1) based on immobilization of a specific monoclonal antibody on gold nanoparticles (GNPs) modified gold electrode. Self-assembly of colloidal gold nanoparticles on the gold electrode was conducted through the thiol groups of 1,6-hexanedithiol (HDT) monolayer as a cross linker. The redox reactions of [Fe(CN)(6)](4-)/[Fe(CN)(6)](3-) on the electrode surface was probed for studying the immobilization and determination processes, using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The interaction of antigen with grafted antibody recognition layer was carried out by soaking the modified electrode into antigen solution at 37°C for 3 h. The immunosensor showed linearity over 1.0-180.0 pg mL(-1) and the limit of detection was 0.15 pg mL(-1). The association constant between IGF-1 and immobilized antibody was calculated to be 9.17×10(11) M(-1). The proposed method is a useful tool for screening picogram amounts of IGF-1 in clinical laboratory as a diagnostic test.  相似文献   

13.
A simple and sensitive label-free electrochemical immunoassay electrode for detection of carcinoembryonic antigen (CEA) has been developed. CEA antibody (CEAAb) was covalently attached on glutathione (GSH) monolayer-modified gold nanoparticle (AuNP) and the resulting CEAAb-AuNP bioconjugates were immobilized on Au electrode by electro-copolymerization with o-aminophenol (OAP). Electrochemical impedance spectroscopy and cyclic voltammetry studies demonstrate that the formation of CEA antibody-antigen complexes increases the electron transfer resistance of [Fe(CN)(6)](3-/4-) redox pair at the poly-OAP/CEAAb-AuNP/Au electrode. The use of CEA antibody-AuNP bioconjugates and poly-OAP film could enhance the sensitivity and anti-nonspecific binding of the resulting immunoassay electrode. The preliminary application of poly-OAP/CEAAb-AuNP/Au electrode for detection of CEA was also evaluated.  相似文献   

14.
The direct electrochemical redox reaction of bovine erythrocyte copper--zinc superoxide dismutase (Cu(2)Zn(2)SOD) was clearly observed at a gold electrode modified with a self-assembled monolayer (SAM) of cysteine in phosphate buffer solution containing SOD, although its reaction could not be observed at the bare electrode. In this case, SOD was found to be stably confined on the SAM of cysteine and the redox response could be observed even when the cysteine-SAM electrode used in the SOD solution was transferred to the pure electrolyte solution containing no SOD, suggesting the permanent binding of SOD via the SAM of cysteine on the electrode surface. The electrode reaction of the SOD confined on the cysteine-SAM electrode was found to be quasi-reversible with the formal potential of 65 +/- 3 mV vs. Ag/AgCl and its kinetic parameters were estimated: the electron transfer rate constant k(s) is 1.2 +/- 0.2 s(-1) and the anodic (alpha(a)) and cathodic (alpha(c)) transfer coefficients are 0.39 +/- 0.02 and 0.61 +/- 0.02, respectively. The assignment of the redox peak of SOD at the cysteine-SAM modified electrode could be sufficiently carried out using the native SOD (Cu(2)Zn(2)SOD), its Cu- or Zn-free derivatives (E(2)Zn(2)SOD and Cu(2)E(2)SOD, E designates an empty site) and the SOD reconstituted from E(2)Zn(2)SOD and Cu(2+). The Cu complex moiety, the active site for the enzymatic dismutation of the superoxide ion, was characterized to be also the electroactive site of SOD. In addition, we found that the SOD confined on the electrode can be expected to possess its inherent enzymatic activity for dismutation of the superoxide ion.  相似文献   

15.
In this study, the cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques were used to investigate the extracellular electron transfer from Escherichia coli JM109. It was demonstrated that the formal redox potential of direct electron transfer between electrode and an E. coli JM109 cell in aerobic buffer corresponds to -0.42 V vs. Ag/AgCl. Based on the electroactivity of bacterial cells, the electrochemical system for definition of sensitivity of microbiological material to antibiotics cefepime, ampicillin, amikacin, and erythromycin was proposed. The results obtained indicate that with electrochemical methods it is possible to provide screening of potential drugs for bacterial diseases. The electrochemical method allows estimating the degree of E. coli JM109 cells resistance to antibiotics within 2-5h using disposable screen-printed graphite electrodes.  相似文献   

16.
A highly sensitive and attractive antifouling impedimetric aptasensor for the determination of thrombin in undiluted serum sample was developed. The aptasensor was fabricated by co-assembling thiol-modified anti-thrombin binding aptamer, dithiothreitol and mercaptohexanol on the surface of gold electrode. The performance of aptasensor was characterized by atomic force microscopy, contact angle and electrochemical impedance spectroscopy. In the measurement of thrombin, the change in interfacial electron transfer resistance of aptasensor was monitored using a redox couple of Fe(CN)(6)(3-/4-). The increase in the electron transfer resistance was linearly proportional to the concentration of thrombin in the range from 1.0 to 20ng/mL and a detection limit of 0.3ng/mL thrombin was achieved. The fabricated aptasensor displayed attractive antifouling properties and allowed direct quantification of extrinsic thrombin down to 0.08ng/mL in undiluted serum sample. This work provides a promising strategy for clinical application with impressive sensitivity and antifouling characteristics.  相似文献   

17.
The enantioselectivity imparted to a gold electrode by modifying its surface with a self-assembled monolayer (SAM) of cysteine (Cys) was investigated for the electrochemical redox reaction of 3,4-dihydroxyphenylalanine (DOPA). A cyclic voltammetric study of the redox reaction revealed that the enantioselectivity was determined by the surface coverage of the gold electrode with Cys molecules. The electrode modified with approximately 1.8 x 10(14) Cys molecules cm(-2) exhibited enantioselectivity in the voltammogram for the oxidation and reduction of DOPA, while the voltammograms obtained by the electrodes with either more or less surface coverages did not exhibit significant enantioselectivity. It is suggested that the accessibility of DOPA to that area of the gold surface which is not blocked by Cys molecules at an optimum surface coverage, is required for the enantioselective redox reaction of DOPA to proceed.  相似文献   

18.
Electrochemical impedance spectroscopy (EIS) was used to monitor the growth of mammalian cancer cells and evaluate the cytotoxicity of chemicals using Fe(CN)6(3-/4-) as a redox probe. Cancer cells, the human hepatocarcinoma cell line (BEL7404), were grown on optically transparent indium tin oxide (ITO) semiconductor slides, which were used as the working electrodes in electrochemical experiments. Attachment and proliferation of cancer cells on ITO surfaces resulted in increase of electron-transfer resistance (R(et)) between the redox probe of Fe(CN)6(3-/4-) in electrolyte solution and ITO electrode surface. For cytotoxicity assessment, cells grown on ITO substrates were further cultured in the presence of different cytotoxicants and electrochemical impedance measurements were carried out at different time intervals. Gemcitabine, a promising antineoplastic drug showing activity against a wide spectrum of human solid tumors, was selected as a model for long-term cytotoxicity effect study, whereas mercury chloride represented a model for acute toxicants. The inhibitions of gemcitabine and mercury chloride on the viability and proliferation of BEL7404 cells were observed from the electrochemical impedance experiments, and the different action modes were discriminated. Additionally, microscope images were also used to observe the effects of these two chemicals on the morphology of the cells. General consistency has been found between the electrochemical impedance response and the morphological observation. Such an impedance method provides a simple and inexpensive way for in vitro assessment of chemical cytotoxicity.  相似文献   

19.
An electrochemical DNA sensor based on the hybridization recognition of a single-stranded DNA (ssDNA) probe immobilized onto a gold electrode to its complementary ssDNA is presented. The DNA probe is bound on gold surface electrode by using self-assembled monolayer (SAM) technology. An optimized mixed SAM with a blocking molecule preventing the nonspecific adsorption on the electrode surface has been prepared. In this paper, a DNA biosensor is designed by means of the immobilization of a single stranded DNA probe on an electrochemical transducer surface to recognize specifically Escherichia coli (E. coli) 0157:H7 complementary target DNA sequence via cyclic voltammetry experiments. The 21 mer DNA probe including a C6 alkanethiol group at the 5' phosphate end has been synthesized to form the SAM onto the gold surface through the gold sulfur bond. The goal of this paper has been to design, characterise and optimise an electrochemical DNA sensor. In order to investigate the oligonucleotide probe immobilization and the hybridization detection, experiments with different concentration of DNA and mismatch sequences have been performed. This microdevice has demonstrated the suitability of oligonucleotide Self-assembled monolayers (SAMs) on gold as immobilization method. The DNA probes deposited on gold surface have been functional and able to detect changes in bases sequence in a 21-mer oligonucleotide.  相似文献   

20.
In this research, we reported a novel method of forming hemoglobin (Hb)-linoleic acid (LA) Langmuir-Blodgett (LB) monolayer by spreading Hb solution directly onto the subphase covered with a layer of LA. This method is suitable for preparing electrochemical devices with protein-lipid LB film because almost no protein adsorbed on electrode surface before protein-lipid film transferred from air-water interface to electrode, which ensured better electrode activity. The compressibility of Hb-LA monolayer was used to character the phase transition during compression process. Optimal experimental conditions were obtained by analyzing pressure-time, pressure-area and pressure-compressibility curves. The direct electrochemistry of Hb, which was immobilized on Au electrode surface incorporated with LA layer by LB method, was investigated using cyclic voltammetry for the first time. The electrode modified with Hb-LA LB film holds high electrochemical activity and shows a fast direct electron transfer of Hb. Redox peak currents increased linearly with the increase of scan rate, indicating a surface-controlled electrode process. The electron transfer rate constant was 2.68+/-0.45 s-1. As a target of this research, this work provides a new way to prepare biomimetic film and biosensor.  相似文献   