首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two flow-injection biosensor systems using semi disposable enzyme reactor have been developed to determine carbamate pesticides in water samples. Acetylcholinesterase was immobilized on silica gel by covalent binding. pH and conductivity electrodes were used to detect the ionic change of the sample solution due to hydrolysis of acetylcholine. Carbamate pesticides inhibited acetylcholinesterase and the decrease in the enzyme activity was used to determine these pesticides. Parameters influencing the performance of the systems were optimized to be used in the inhibition procedure. Carbofuran and carbaryl were used to test these systems. Detection limits for the potentiometric and conductimetric systems were both at 10% inhibition corresponding to 0.02 and 0.3 ppm of carbofuran and carbaryl, respectively. Both systems also provided the same linear ranges, 0.02-8.0 ppm for carbofuran, and 0.3-10 ppm for carbaryl. The analysis of pesticides was done a few times before the reactor was disposed. Percentages of inhibition obtained from different reactors were reproducible, therefore, no recalibration was necessary when changing the reactor. The biosensors were used to analyze carbaryl in water samples from six wells in a vegetable growing area. Both systems could detect the presence of carbaryl in the samples and provided good recoveries of the added carbaryl, i.e., 80-106% for the potentiometric system and 75-105% for the conductimetric system. The presence of carbaryl in water samples analyzed by the biosensors was confirmed by gas chromatography-mass spectrometric system. These biosensors do not require any sample preconcentration and are suitable for detecting pesticides in real water samples.  相似文献   

2.
Analytical technology based on sensors is an extremely broad field which impacts on many major industrial sectors such as the pharmaceutical, healthcare, food, and agriculture industries as well as environmental monitoring. This review will highlight the research carried out during the last 5 years on biosensors that are based on enzyme inhibition for determination of pollutants and toxic compounds in a wide range of samples. Here the different enzymes implicated in the inhibition, different transducers forming the sensing devices, and the different contaminants analyzed are considered. The general application of the various biosensors developed, with emphasis on food and environmental applications, is reviewed as well as the general approaches that have been used for enzyme immobilization, the enzyme catalysis, and the inhibition mechanism.  相似文献   

3.
生物传感器在环境分析中的研究现状与前景   总被引:3,自引:0,他引:3  
论述生物传感器的发展现状与前景。在环境控制中,生物传感器作为广谱装置应用于废水或生化需氧量的检测以及特异性地对农药、重金属、硝酸盐、亚硝酸盐、除草剂和次氮基乙酸等环境污染物进行检测。讨论了各类生物传感器(如酶生物传感器、全细胞生物传感器、受体传感器和免疫传感器)在环境分析中的应用实例及其优缺点,并指出了急需解决的问题以阐明其应用趋势,以期在这一跨学科领域进行更多的研究。  相似文献   

4.
A conductometric biosensor using immobilised Chlorella vulgaris microalgae as bioreceptors was used as a bi-enzymatic biosensor. Algae were immobilised inside bovine serum albumin membranes reticulated with glutaraldehyde vapours deposited on interdigitated conductometric electrodes. Local conductivity variations caused by algae alkaline phosphatase and acetylcholinesterase activities could be detected. These two enzymes are known to be inhibited by distinct families of toxic compounds: heavy metals for alkaline phosphatase, carbamates and organophosphorous (OP) pesticides for acetylcholinesterase. The bi-enzymatic biosensors were tested to study the influence of heavy metal ions and pesticides on the corresponding enzyme. It has finally appeared that these biosensors are quite sensitive to Cd2+ and Zn2+ (limits of detection (LOD) = 10 ppb for a 30 min long exposure) while Pb2+ gives no significant inhibition as this ion seems to adsorb on albumin preferably. For pesticides, first experiments showed that paraoxon-methyl inhibits C. vulgaris AChE contrary to parathion-methyl and carbofuran. Biosensors were then exposed to different mixtures (Cd2+/Zn2+, Cd2+/paraoxon-methyl) but no synergetic or antagonist effect could be observed. A good repeatability could be achieve with biosensors since the relative standard deviation did not exceed 8% while response time was 5-7 min. A comparison between inhibition levels obtained with biosensors (after a 30 min long exposure) and bioassays (after a 240 min long exposure) has finally shown a similar LOD for both Cd and Zn (LOD = 10 ppb).  相似文献   

5.
Highly sensitive biosensors based on pH-sensitive field effect transistors and cholinesterases for detection of solanaceous glycoalkaloids have been developed, characterised and optimised. The main analytical characteristics of the biosensors developed have been studied under different conditions and an optimal experimental protocol for glycoalkaloids determination in model solution has been proposed. Using such a biosensor and an enzyme reversible inhibition effect, the total potato glycoalkaloids content can be determined within the range of 0.2-100 microM depending on the type of alkaloid, with lowest detection limits of 0.2 microM for alpha-chaconine, 0.5 microM for alpha-solanine and 1 microM for solanidine. The dynamic ranges for the compounds examined show that such biosensors are suitable for a quantitative detection of glycoalkaloids in real potato samples. High reproducibility, operational and storage stability of the biosensor developed have been shown.  相似文献   

6.
The optical transducer of CdTe semiconductor quantum dots (QDs) has been integrated with acetylcholinesterase enzyme (AChE) by the layer-by-layer (LbL) assembly technique, resulting in a highly sensitive biosensor for detection of organophosphorus pesticides (OPs) in vegetables and fruits based on enzyme inhibition mechanism. The detection limits of the proposed biosensors are as low as 1.05 × 10(-11) M for paraoxon and 4.47 × 10(-12) M for parathion, which are significantly better than those of the conventional GC/MS methods or amperometric biosensors (0.5 nM). These biosensors are used for quick determination of low concentrations of OPs in real vegetable and fruit samples and exhibit satisfactory reproducibility and accuracy. Moreover, the stock stability of the biosensors are very good due to the stabilizing environment for the enzyme in the nanostructures made by LbL technique. Many advantages provided by these biosensors, like fluorescent change recognized by naked eyes and mass production with low cost, will facilitate future development of rapid and high-throughput screening of OPs.  相似文献   

7.
Since 1992, when the room temperature ionic liquids (ILs) based on the 1-alkyl-3-methylimidazolium cation were reported to provide an attractive combination of an electrochemical solvent and electrolyte, ILs have been widely used in electrodeposition, electrosynthesis, electrocatalysis, electrochemical capacitor, and lithium batteries. However, it has only been in the last few years that electrochemical biosensors based on carbon ionic liquid electrodes (CILEs) and IL-modified macrodisk electrodes have been reported. However, there are still a lot of challenges in achieving IL-based sensitive, selective, and reproducible biosensors for high speed analysis of biological and environmental compounds of interest. This review discusses the principles of operation of electrochemical biosensors based on CILEs and IL/composite-modified macrodisk electrodes. Subsequently, recent developments and major strategies for enhancing sensing performance are discussed. Key challenges and opportunities of IL-based biosensors to further development and use are considered. Emphasis is given to direct electron-transfer reaction and electrocatalysis of hemeproteins and enzyme-modified composite electrodes.  相似文献   

8.
生物传感器在环境分析中的研究现状与前景   总被引:1,自引:0,他引:1  
在环境控制中,生物传感器作为广谱装置应用于废水或生化需氧量的检测,特异性地对农药、重金属、硝酸盐、亚硝酸盐、除草剂和次氮基乙酸等环境污染物进行检测。讨论了各类生物传感器(酶生物传感器、全细胞生物传感器、受本传感器和免疫传感器)在环境分析中的应用实例及其优缺点,并指出了急需解决的问题以阐明其应用趋势。  相似文献   

9.
Benzene, toluene, ethylbenzene and xylenes (BTEX) contamination is a serious threat to public health and the environment, and therefore, there is an urgent need to detect its presence in nature. The use of whole‐cell reporters is an efficient, easy‐to‐use and low‐cost approach to detect and follow contaminants outside specialized laboratories; this is especially important in oil spills that are frequent in marine environments. The aim of this study is the construction of a bioreporter system and its comparison and validation for the specific detection of monocyclic aromatic hydrocarbons in different host bacteria and environmental samples. Our bioreporter system is based on the two component regulatory system TodS–TodT of P. putida DOT‐T1E, and the PtodX promoter fused to the GFP protein as the reporter protein. For the construction of different biosensors, this bioreporter was transferred into three different bacterial strains isolated from three different environments, and their performance was measured. Validation of the biosensors on water samples spiked with petrol, diesel and crude oil on contaminated waters from oil spills and on contaminated soils demonstrated that they can be used in mapping and monitoring some BTEX compounds (specifically benzene, toluene and two xylene isomers). Validation of biosensors is an important issue for the integration of these devices into pollution‐control programmes.  相似文献   

10.
Synthetic biology has promoted the development of biosensors as tools for detecting trace substances. In the past, biosensors based on synthetic biology have been designed on living cells, but the development of cell biosensors has been greatly limited by defects such as genetically modified organism problem and the obstruction of cell membrane. However, the advent of cell‐free synthetic biology addresses these limitations. Biosensors based on the cell‐free protein synthesis system have the advantages of higher safety, higher sensitivity, and faster response time over cell biosensors, which make cell‐free biosensors have a broader application prospect. This review summarizes the workflow of various cell‐free biosensors, including the identification of analytes and signal output. The detection range of cell‐free biosensors is greatly enlarged by different recognition mechanisms and output methods. In addition, the review also discusses the applications of cell‐free biosensors in environmental monitoring and health diagnosis, as well as existing deficiencies and aspects that should be improved. In the future, through continuous improvement and optimization, the potential of cell‐free biosensors will be stimulated, and their application fields will be expanded.  相似文献   

11.
12.
Carbon nanotubes (CNTs) are promising components for electrical biosensors due to their high surface‐to‐volume ratio and improved electron transfer properties. This review surveys CNT‐based label‐free indicator‐free biosensing strategies that have been demonstrated for the sensitive detection of nucleic acids. After an introduction to CNTs, the fabrication of biosensors and techniques for the immobilization of probe nucleic acids are outlined. Subsequently, two major label‐free strategies namely electrochemical transduction and field‐effect detection are presented. The focus is on direct detection methods that avoid labels, indicators, intercalating agents, mediators, and even secondary receptors. The review concludes with a comparison between the various biosensors and presents ways of engineering them so that they can be deployed in realistic diagnostic applications.  相似文献   

13.
Globally, sustainable provision of high‐quality safe water is a major challenge of the 21st century. Various chemical and biological monitoring analytics are presently utilized to guarantee the availability of high‐quality water. However, these techniques still face some challenges including high costs, complex design and onsite and online limitations. The recent technology of using microbial fuel cell (MFC)‐based biosensors holds outstanding potential for the rapid and real‐time monitoring of water source quality. MFCs have the advantages of simplicity in design and efficiency for onsite sensing. Even though some sensing applications of MFCs were previously studied, e.g. biochemical oxygen demand sensor, recently numerous research groups around the world have presented new practical applications of this technique, which combine multidisciplinary scientific knowledge in materials science, microbiology and electrochemistry fields. This review presents the most updated research on the utilization of MFCs as potential biosensors for monitoring water quality and considers the range of potentially toxic analytes that have so far been detected using this methodology. The advantages of MFCs over established technology are also considered as well as future work required to establish their routine use.  相似文献   

14.
A novel biosensor based on immobilised whole cell Chlorella vulgaris microalgae as a bioreceptor and interdigitated conductometric electrodes as a transducer has been developed and tested for alkaline phosphatase activity (APA) analysis. These sensors were also used for the detection of toxic compounds, namely cadmium ions, in aquatic habitats. Algae were immobilised inside bovine serum albumin (BSA) membranes cross-linked with glutaraldehyde vapours. The detection of the local conductivity variations caused by algae enzymatic reactions could be achieved. The inhibition of C. vulgaris microalgae Alkaline phosphatase activities in presence of cadmium ions was measured. These results were compared with measurements in bioassays. It finally appeared that conductometric biosensors using algae seemed more sensitive than bioassays to detect low levels of cadmium ions (the detection limit for the first experiments was 1 ppb of Cd2+). The main advantages of these alkaline phosphatase biosensors consist of their high specificity in regard to the toxic compounds they enable to detect, but also on their high stability since contrary to enzymatic biosensors, they use whole algae cells with APs on their walls.  相似文献   

15.
Biosensors are low-cost and low-maintenance alternatives to conventional analytical techniques for biomedical, industrial and environmental applications. Biosensors based on whole microorganisms can be genetically engineered to attain high sensitivity and specificity for the detection of selected analytes. While bacteria-based biosensors have been extensively reported, there is a recent interest in yeast-based biosensors, combining the microbial with the eukaryotic advantages, including possession of specific receptors, stability and high robustness. Here, we describe recently reported yeast-based biosensors highlighting their biological and technical features together with their status of development, that is, laboratory or prototype. Notably, most yeast-based biosensors are still in the early developmental stage, with only a few prototypes tested for real applications. Open challenges, including systematic use of advanced molecular and biotechnological tools, bioprospecting, and implementation of yeast-based biosensors in electrochemical setup, are discussed to find possible solutions for overcoming bottlenecks and promote real-world application of yeast-based biosensors.  相似文献   

16.
Making bio-sense of toxicity: new developments in whole-cell biosensors   总被引:1,自引:0,他引:1  
Bacterial whole-cell biosensors are very useful for toxicity measurements of various samples. Semi-specific biosensors, containing fusions of stress-regulated promoters and reporter genes, have several advantages over the traditional, general biosensors that are based on constitutively expressed reporter genes. Furthermore, semi-specific biosensors are constantly being refined to lower their sensitivity and, in combination, are able to detect a wide range of toxic agents. However, the requirement for a positive response of these biosensors to toxicants can result in false-negative responses. The application of in situ inoculation and single-cell detection, combined with the introduction of new reporter genes and refined detection equipment, could lead to the extensive use of semi-specific, stress-responsive biosensors for toxicity estimations in the future.  相似文献   

17.
This review presents with selected examples the versatility of nuclear magnetic resonance (NMR) spectroscopy in the analysis of toxic organophosphorus (OP) compounds, i.e. OP pesticides and chemical warfare agents (CWAs). Several NMR applications of biological importance, like studies on inhibition mechanism, metabolism, and exposure determination, are presented. The review also concerns with the environmental analysis of OP compounds by NMR spectroscopy. Residue analysis of environment and food samples as well as characterization of degradation in environment is discussed. Some of the NMR studies that have been done to support the Chemical Weapons Convention, i.e. the development of suitable CWA detoxification means and the method development of verification analysis for CWAs and their degradation products, are outlined.  相似文献   

18.
Detection of microorganisms and microbial toxins is important for health and safety. Due to their unique physical and chemical properties, nanomaterials have been extensively used to develop biosensors for rapid detection of microorganisms with microbial cells and toxins as target analytes. In this paper, the design principles of nanomaterials‐based biosensors for four selected analyte categories (bacteria cells, toxins, mycotoxins, and protozoa cells), closely associated with the target analytes' properties is reviewed. Five signal transducing methods that are less equipment intensive (colorimetric, fluorimetric, surface enhanced Raman scattering, electrochemical, and magnetic relaxometry methods) is described and compared for their sensory performance (in term oflimit of detection, dynamic range, and response time) for all analyte categories. In the end, the suitability of these five sensing principles for on‐site or field applications is discussed. With a comprehensive coverage of nanomaterials, design principles, sensing principles, and assessment on the sensory performance and suitability for on‐site application, this review offers valuable insight and perspective for designing suitable nanomaterials‐based microorganism biosensors for a given application.  相似文献   

19.
Results of the research performed at the Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, on designing immunobiosensors for detection of toxic compounds and microbial cells enzyme-based biosensors for detection of hydrocarbons and alcohols, and microbial biosensors for aromatic compounds, surfactants, and biological oxygen consumption are briefed. Parameters of the mediator electrodes involving microbial cells and data on the properties of microbial biofuel cells--devices based on biosensor principle and representing alternative sources of electric energy--are given.  相似文献   

20.
Results of the research performed at the Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, on designing immunobiosensors for detection of toxic compounds and microbial cells, enzyme-based biosensors for detection of hydrocarbons and alcohols, and microbial biosensors for aromatic compounds, surfactants, and biological oxygen consumption are reviewed. Parameters of the mediator electrodes involving microbial cells and data on the properties of microbial biofuel cells—devices based on the biosensor principle and representing alternative sources of electric energy—are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号