首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A limitation in the use of invasive coronary diagnostic indexes is that fluctuations in hemodynamic factors such as heart rate (HR), blood pressure, and contractility may alter resting or hyperemic flow measurements and may introduce uncertainties in the interpretation of these indexes. In this study, we focused on the effect of fluctuations in HR and area stenosis (AS) on diagnostic indexes. We hypothesized that the pressure drop coefficient (CDP(e), ratio of transstenotic pressure drop and distal dynamic pressure), lesion flow coefficient (LFC, square root of ratio of limiting value CDP and CDP at site of stenosis) derived from fluid dynamics principles, and fractional flow reserve (FFR, ratio of average distal and proximal pressures) are independent of HR and can significantly differentiate between the severity of stenosis. Cardiac catheterization was performed on 11 Yorkshire pigs. Simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual sensor-tipped guidewire for HR < 120 and HR > 120 beats/min, in the presence of epicardial coronary lesions of <50% AS and >50% AS. The mean values of FFR, CDP(e), and LFC were significantly different (P < 0.05) for lesions of <50% AS and >50% AS (0.88 ± 0.04, 0.76 ± 0.04; 62 ± 30, 151 ± 35, and 0.10 ± 0.02 and 0.16 ± 0.01, respectively). The mean values of FFR and CDP(e) were not significantly different (P > 0.05) for variable HR conditions of HR < 120 and HR > 120 beats/min (FFR, 0.81 ± 0.04 and 0.82 ± 0.04; and CDP(e), 95 ± 33 and 118 ± 36). The mean values of LFC do somewhat vary with HR (0.14 ± 0.01 and 0.12 ± 0.02). In conclusion, fluctuations in HR have no significant influence on the measured values of CDP(e) and FFR but have a marginal influence on the measured values of LFC. However, all three parameters can significantly differentiate between stenosis severities. These results suggest that the diagnostic parameters can be potentially used in a better assessment of coronary stenosis severity under a clinical setting.  相似文献   

2.
Functional diagnostic parameters such as Fractional Flow Reserve (FFR), which is calculated from pressure measurements across stenosed arteries, are often used to determine the functional severity of coronary artery stenosis. This study evaluated the effect of arterial wall-stenosis compliance, with limiting scenarios of stenosis severity, on the diagnostic parameters. The diagnostic parameters considered in this study include an established index, FFR and two recently developed parameters: Pressure Drop Coefficient (CDP) and Lesion Flow Coefficient (LFC). The parameters were assessed for rigid artery (RR; signifying high plaque elasticity), compliant artery with calcified plaque (CC; intermediate plaque elasticity) and compliant artery with smooth muscle cell proliferation (CS; low plaque elasticity), with varying degrees of epicardial stenosis. A hyperelastic Mooney-Rivlin model was used to model the arterial wall and plaque materials. Blood was modeled as a shear thinning, non-Newtonian fluid using the Carreau model. The arterial wall compliance was evaluated using the finite element method. The present study found that, with an increase in stenosis severity, FFR decreased whereas CDP and LFC increased. The cutoff value of 0.75 for FFR was observed at 78.7% area stenosis for RR, whereas for CC and CS the cutoff values were obtained at higher stenosis severities of 81.3% and 82.7%, respectively. For a fixed stenosis, CDP value decreased and LFC value increased with a decrease in plaque elasticity (RR to CS). We conclude that the differences in diagnostic parameters with compliance at intermediate stenosis (78.7-82.7% area blockage) could lead to misinterpretation of the stenosis severity.  相似文献   

3.
Diagnosis of the ischemic power of epicardial stenosis with concomitant microvascular disease (MVD) is challenging during coronary interventions, especially under variable hemodynamic factors like heart rate (HR). The goal of this study is to assess the influence of variable HR and percent area stenosis (%AS) in the presence of MVD on pressure drop coefficient (CDP; ratio of transstenotic pressure drop to the distal dynamic pressure) and lesion flow coefficient (LFC; ratio of %AS to the CDP at the throat region). We hypothesize that CDP and LFC are independent of HR. %AS and MVD were created using angioplasty balloons and 90-μm microspheres, respectively. Simultaneous measurements of pressure drop (DP) and velocity were done in 11 Yorkshire pigs. Fractional flow reserve (FFR), CDP, and LFC were calculated for the groups HR < 120 and HR > 120 beats/min, %AS < 50 and %AS > 50, and additionally for DP < 14 and DP > 14 mmHg, and analyzed using regression and ANOVA analysis. Regression analysis showed independence between HR and the FFR, CDP, and LFC while it showed dependence between %AS and the FFR, CDP, and LFC. In the ANOVA analysis, for the HR < 120 beats/min and HR > 120 beats/min groups, the values of FFR (0.82 ± 0.02 and 0.82 ± 0.02), CDP (83.15 ± 26.19 and 98.62 ± 26.04), and LFC (0.16 ± 0.03 and 0.15 ± 0.03) were not significantly different (P > 0.05). However, for %AS < 50 and %AS > 50, the FFR (0.89 ± 0.02 and 0.75 ± 0.02), CDP (35.97 ± 25.79.10 and 143.80 ± 25.41), and LFC (0.09 ± 0.03 and 0.22 ± 0.03) were significantly different (P < 0.05). A similar trend was observed between the DP groups. Under MVD conditions, FFR, CDP, and LFC were not significantly influenced by changes in HR, while they can significantly distinguish %AS and DP groups.  相似文献   

4.
Depending on stenosis severity, collateral flow can be a confounding factor in the determination of coronary hyperemic microvascular resistance (HMR). Under certain assumptions, the calculation of HMR can be corrected for collateral flow by incorporating the wedge pressure (P(w)) in the calculation. However, although P(w) > 25 mmHg is indicative of collateral flow, P(w) does in part also reflect myocardial wall stress neglected in the assumptions. Therefore, the aim of this study was to establish whether adjusting HMR by P(w) is pertinent for a diagnostically relevant range of stenosis severities as expressed by fractional flow reserve (FFR). Accordingly, intracoronary pressure and Doppler flow velocity were measured a total of 95 times in 29 patients distal to a coronary stenosis before and after stepwise percutaneous coronary intervention. HMR was calculated without (HMR) and with P(w)-based adjustment for collateral flow (HMR(C)). FFR ranged from 0.3 to 1. HMR varied between 1 and 5 and HMR(C) between 0.5 and 4.2 mmHg·cm(-1)·s. HMR was about 37% higher than HMR(C) for stenoses with FFR < 0.6, but for FFR > 0.8, the relative difference was reduced to 4.4 ± 3.4%. In the diagnostically relevant range of FFR between 0.6 and 0.8, this difference was 16.5 ± 10.4%. In conclusion, P(w)-based adjustment likely overestimates the effect of potential collateral flow and is not needed for the assessment of coronary HMR in the presence of a flow-limiting stenosis characterized by FFR between 0.6 and 0.8 or for nonsignificant lesions.  相似文献   

5.
Coronary Artery Disease (CAD) is responsible for most of the deaths in patients with cardiovascular diseases. Diagnostic coronary angiography analysis offers an anatomical knowledge of the severity of the stenosis. The functional or physiological significance is more valuable than the anatomical significance of CAD. Clinicians assess the functional severity of the stenosis by resorting to an invasive measurement of the pressure drop and flow. Hemodynamic parameters, such as pressure wire assessment fractional flow reserve (FFR) or Doppler wire assessment coronary flow reserve (CFR) are well-proven techniques to evaluate the physiological significance of the coronary artery stenosis in the cardiac catheterization laboratory. Between the two techniques mentioned above, the FFR is seen as a very useful index. The presence of guide wire reduces the coronary flow which causes the underestimation of pressure drop across the stenosis which leads to dilemma for the clinicians in the assessment of moderate stenosis. In such condition, the fundamental fluid mechanics is useful in the development of new functional severity parameters such as pressure drop coefficient and lesion flow coefficient. Since the flow takes place in a narrowed artery, the blood behaves as a non-Newtonian fluid. Computational fluid dynamics (CFD) allows a complete coronary flow simulation to study the relationship between the pressure and flow. This paper aims at explaining (i) diagnostic modalities for the evaluation of the CAD and valuable insights regarding FFR in the evaluation of the functional severity of the CAD (ii) the role of fluid dynamics in measuring the severity of CAD.  相似文献   

6.
The decision to perform intervention on a patient with coronary stenosis is often based on functional diagnostic parameters obtained from pressure and flow measurements using sensor-tipped guidewire at maximal vasodilation (hyperemia). Recently, a rapid exchange Monorail Pressure Sensor catheter of 0.022″ diameter (MPS22), with pressure sensor at distal end has been developed for improved assessment of stenosis severity. The hollow shaft of the MPS22 is designed to slide over any standard 0.014″ guidewire (G14). Hence, influence of MPS22 diameter on coronary diagnostic parameters needs investigation. An in vitro experiment was conducted to replicate physiologic flows in three representative area stenosis (AS): mild (64% AS), intermediate (80% AS), and severe (90% AS), for two arterial diameters, 3 mm (N2; more common) and 2.5 mm (N1). Influence of MPS22 on diagnostic parameters: fractional flow reserve (FFR) and pressure drop coefficient (CDP) was evaluated both at hyperemic and basal conditions, while comparing it with G14. The FFR values decreased for the MPS22 in comparison to G14, (Mild: 0.87 vs 0.88, Intermediate: 0.68 vs 0.73, Severe: 0.48 vs 0.56) and CDP values increased (Mild: 16 vs 14, Intermediate: 75 vs 56, Severe: 370 vs 182) for N2. Similar trend was observed in the case of N1. The FFR values were found to be well above (mild) and below (intermediate and severe) the diagnostic cut-off of 0.75. Therefore, MPS22 catheter can be used as a possible alternative to G14. Further, irrespective of the MPS22 or G14, basal FFR (FFRb) had overlapping ranges in close proximity for clinically relevant mild and intermediate stenoses that will lead to diagnostic uncertainty under both N1 and N2. However, CDPb had distinct ranges for different stenosis severities and could be a potential diagnostic parameter under basal conditions.  相似文献   

7.
The aim of this study was to assess the influence of a second guidewire on the diagnostic accuracy of functional parameters of coronary lesion severity. Sixty-five patients with intermediate coronary lesions underwent myocardial perfusion scintigraphy. Fractional flow reserve (FFR), coronary flow velocity reserve (CFVR), and hyperemic stenosis resistance (HSR) index (HSR = stenosis pressure gradient / velocity) were determined in 77 lesions. Distal pressure and velocity were acquired simultaneously (dual wire) and sequentially (single wire) with two sensor-equipped guidewires. Overall, functional parameters deteriorated from single- to dual-wire assessment. In patients without ischemia, the good diagnostic performance of FFR, CFVR, and HSR deteriorated significantly (P < 0.001) when assessed by dual wires, with an increase in the number of false-positive results. This trend was more pronounced for HSR, since the presence of a second wire reduced maximal velocity and increased the pressure gradient. The presence of two guidewires, especially across a myocardial perfusion scintigraphy-induced nonsignificant lesion, is associated with overestimation of the hemodynamically assessed lesion severity and, therefore, is likely to have a major impact on clinical decision making. This underscores the advantage of a dual-sensor-equipped guidewire for the evaluation of stenosis severity by combined pressure and velocity measurements.  相似文献   

8.
Fractional flow reserve (FFR) is an important diagnostic tool to guide decision-making in the cardiac catheterisation laboratory and for evaluation of percutaneous coronary interventions (PCI). Especially the pressure pullback curve at maximal hyperaemia is convincing in demonstrating the exact location and severity of a coronary stenosis. This pressure pullback curve can also demonstrate the presence of diffuse disease. We present a case in which FFR with pressure pullback curve seven days after a PCI, which did not result in complete symptom relief, indicates the presence of diffuse disease. Based on this result the patient was treated medically.  相似文献   

9.
Myocardial fractional flow reserve (FFR(myo)) and coronary flow reserve (CFR), measured with guidewire, and quantitative angiography (QA) are widely used in combination to distinguish ischemic from non-ischemic coronary stenoses. Recent studies have shown that simultaneous measurements of FFR(myo) and CFR are recommended to dissociate conduit epicardial coronary stenoses from distal resistance microvascular disease. In this study, a more comprehensive diagnostic parameter, named as lesion flow coefficient, c, is proposed. The coefficient, c, which accounts for mean pressure drop, Delta p, mean coronary flow, Q, and percentage area stenosis, can be used to assess the hemodynamic severity of a coronary artery stenoses. Importantly, the contribution of viscous loss and loss due to momentum change for several lesion sizes can be distinguished using c. FFR(myo), CFR and c were calculated for pre-angioplasty, intermediate and post-angioplasty epicardial lesions, without microvascular disease. While hyperemic c decreased from 0.65 for pre-angioplasty to 0.48 for post-angioplasty lesion with guidewire of size 0.35 mm, FFR(myo) increased from 0.52 to 0.87, and CFR increased from 1.72 to 3.45, respectively. Thus, reduced loss produced by momentum change due to lower percentage area stenosis decreased c. For post-angioplasty lesion, c decreased from 0.55 to 0.48 with the insertion of guidewire. Hence, increased viscous loss due to the presence of guidewire decreased c compared with a lesion without guidewire. Further, c showed a linear relationship with FFR(myo), CFR and percentage area stenosis for pre-angioplasty, intermediate and post-angioplasty lesion. These baseline values of c were developed from fluid dynamics fundamentals for focal lesions, and provided a single hemodynamic endpoint to evaluate coronary stenosis severity.  相似文献   

10.
Pressure-based fractional flow reserve (FFR) is used clinically to evaluate the functional severity of a coronary stenosis, by predicting relative maximal coronary flow (Q(s)/Q(n)). It is considered to be independent of hemodynamic conditions, which seems unlikely because stenosis resistance is flow dependent. Using a resistive model of an epicardial stenosis (0-80% diameter reduction) in series with the coronary microcirculation at maximal vasodilation, we evaluated FFR for changes in coronary microvascular resistance (R(cor) = 0.2-0.6 mmHg. ml(-1). min), aortic pressure (P(a) = 70-130 mmHg), and coronary outflow pressure (P(b) = 0-15 mmHg). For a given stenosis, FFR increased with decreasing P(a) or increasing R(cor). The sensitivity of FFR to these hemodynamic changes was highest for stenoses of intermediate severity. For P(b) > 0, FFR progressively exceeded Q(s)/Q(n) with increasing stenosis severity unless P(b) was included in the calculation of FFR. Although the P(b)-corrected FFR equaled Q(s)/Q(n) for a given stenosis, both parameters remained equally dependent on hemodynamic conditions, through their direct relationship to both stenosis and coronary resistance.  相似文献   

11.

Background  

The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true severity of epicardial stenosis, we evaluate a diagnostic parameter, which is obtained from fundamental fluid dynamics principles. This experimental and numerical study focuses on the characterization of the diagnostic parameter, pressure drop coefficient, and also evaluates the pressure recovery downstream of stenoses.  相似文献   

12.
Clinical studies reported that some vulnerable stenoses deformed their shape in a blood vessel based on flow condition. However, the effects of shape variation on flow characteristics remain unclear. The flow characteristics are known to affect vulnerable stenosis rupture and fractional flow reserve (FFR) value which has been widely used as a diagnostic tool for stenosis. Vulnerable stenosis rupture occurs when the structural stress exerted on a fibrous cap exceeds its tolerable threshold. The stress magnitude is determined from the spatial distribution of static pressure around the stenosis. In the present study, the static pressure distribution and the FFR value in deformable stenosis were investigated with related other flow characteristics. Two phantom models were fabricated to mimic deformable and nondeformable stenoses using polydimethylsiloxane. The flow characteristics were observed under a steady-flow condition at three Reynolds numbers (Re = 500, 1000, 1500) using a particle image velocimetry. The pressure drop across the stenosis models were measured using a pressure sensor to determine effects of shape deformation on FFR value. Shape variations and jet deflections were clearly observed in the deformable stenosis model, and the effective severity of the stenosis increased up to 17.2%. The shape variations of deformable stenosis model increased the static pressure difference at the upstream and downstream sides of the stenosis. The pressure drop across the deformable stenosis model was significantly higher than that of the nondeformable stenosis model. The present results substantiate that stenosis deformability should be carefully considered to diagnose the rupture of vulnerable stenosis.  相似文献   

13.
To evaluate the hemodynamic impact of coronary stenoses, the fractional (FFR) or coronary flow velocity reserve (CFVR) usually is measured. The combined measurement of instantaneous flow velocity and pressure gradient (v-dp relation) is rarely used in humans. We derived from the v-dp relation a new index, dp(v50) (pressure gradient at flow velocity of 50 cm/s), and compared the diagnostic performance of dp(v50), CFVR, and FFR. Before coronary angiography was performed, patients underwent noninvasive stress testing. In all coronary vessels with an intermediate or severe stenosis, the flow velocity, aortic, and distal coronary pressure were measured simultaneously with a Doppler and pressure guidewire after induction of hyperemia. After regression analysis of all middiastolic flow velocity and pressure gradient data, the dp(v50) was calculated. With the use of the results of noninvasive stress testing, the dp(v50) cutoff value was established at 22.4 mmHg. In 77 patients, 124 coronary vessels with a mean 39% (SD 19) diameter stenosis were analyzed. In 43 stenoses, ischemia was detected. We found a sensitivity, specificity, and accuracy of 56%, 86%, and 76% for CFVR; 77%, 99%, and 91% for FFR; and 95%, 95%, and 95% for dp(v50). To establish that dp(v50) is not dependent on maximal hyperemia, dp(v50) was recalculated after omission of the highest quartile of flow velocity data, showing a difference of 3%. We found that dp(v50) provided the highest sensitivity and accuracy compared with FFR and CFVR in the assessment of coronary stenoses. In contrast to CFVR and FFR, assessment of dp(v50) is not dependent on maximal hyperemia.  相似文献   

14.
Purpose

Invasive fractional flow reserve (FFR), the reference standard for identifying significant coronary artery disease (CAD), can be estimated non-invasively by computed tomography-derived fractional flow reserve (CT-FFR). Commercially available off-site CT-FFR showed improved diagnostic accuracy compared to coronary computed tomography angiography (CCTA) alone. However, the diagnostic performance of this lumped-parameter on-site method is unknown. The aim of this cross-sectional study was to determine the diagnostic accuracy of on-site CT-FFR in patients with suspected CAD.

Methods

A total of 61 patients underwent CCTA and invasive coronary angiography with FFR measured in 88 vessels. Significant CAD was defined as FFR and CT-FFR below 0.80. CCTA with stenosis above 50% was regarded as significant CAD. The diagnostic performance of both CT-FFR and CCTA was assessed using invasive FFR as the reference standard.

Results

Of the 88 vessels included in the analysis, 34 had an FFR of ≤?0.80. On a per-vessel basis, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 91.2%, 81.4%, 93.6%, 75.6% and 85.2% for CT-FFR and were 94.1%, 68.5%, 94.9%, 65.3% and 78.4% for CCTA. The area under the receiver operating characteristic curve was 0.91 and 0.85 for CT-FFR and CCTA, respectively, on a per-vessel basis.

Conclusion

On-site non-invasive FFR derived from CCTA improves diagnostic accuracy compared to CCTA without additional testing and has the potential to be integrated in the current clinical work-up for diagnosing stable CAD.

  相似文献   

15.
The association between the levels of N-terminal pro-brain natriuretic peptide (NT-proBNP) and the severity of coronary artery disease (CAD) diagnosed by coronary angiography and other approaches has been investigated. The clinical application of NT-proBNP is restricted by the drawbacks of these techniques now available in screening out patients who need intensive or conservative treatment. Fractional flow reserve (FFR) is superior to coronary angiography and other functional indicators. Accordingly, we designed to investigate the association between NT-proBNP and myocardial ischemia from the perspective of anatomy and physiology in patients with unstable angina and preserved left ventricular function. Plasma samples were collected from 110 patients and NT-proBNP levels were measured by radioimmunoassay. The severity of coronary artery stenosis in patients was measured by coronary angiography and FFR. Stenosis ≥50% in the left main artery or stenosis of 70%, and fractional flow reserve (FFR) ≤0.80 in one or more coronary branches with diameter ≥2 mm were defined as “positive”, which require revascularization. NT-proBNP levels increased progressively between patients with negative and positive angiographic results (p < 0.05), and between FFR-negative and FFR-positive patients (p < 0.05). A significant correlation was observed between log NT-proBNP and log GS (GS = Gensini score, p < 0.001). NT-proBNP level serves as a predictor of positive results of angiographic stenosis and FFR, with the area under the receiver operating characteristic curve being 0.697 and 0.787, respectively. NT-proBNP levels are correlated with the severity of anatomic coronary obstruction and inducible myocardial ischemia, but NT-proBNP per se is insufficient to identify clinically significant angiographic and physiological stenoses.  相似文献   

16.
Coronary artery pressure-drop and distensibility (compliance) are two major, seemingly unrelated, parameters in the cardiovascular clinical setting, which are indicative of coronary arteries patency and atherosclerosis severity. While pressure drop is related to flow, and therefore serves as a functional indicator of a stenosis severity, the arterial distensibility is indicative of the arterial stiffness, and hence the arterial wall composition. In the present study, we hypothesized that local pressure drops are dependent on the arterial distensibility, and hence can provide information on both indices. The clinical significance is that a single measurement of pressure drop could potentially provide both functional and bio-mechanical metrics of lesions, and thus assist in real-time decision making prior to stenting. The goal of the current study was to set the basis for understanding this relationship, and define the accuracy and sensitivity required from the pressure measurement system. The investigation was performed using numerical fluid–structure interaction (FSI) simulations, validated experimentally using our high accuracy differential pressure measurement system. Simplified silicone mock coronary arteries with zero to intermediate size stenoses were used, and various combinations of arterial distensibility, diameter, and flow rate were simulated. Results of hyperemic flow cases were also compared to fractional flow reserve (FFR). The results indicate the potential clinical superiority of a high accuracy pressure drop-based parameter over FFR, by: (i) being more lesion-specific, (ii) the possibility to circumvent the FFR dependency on pharmacologically-induced hyperemia, and, (iii) by providing both functional and biomechanical lesion-specific information.  相似文献   

17.
To study the effects of exercise on collateral development in myocardial ischemia, we induced coronary arterial stenosis of the left circumflex coronary artery (LCCA) in 18 of 30 pigs. During that surgery, we identified the coronary bed at risk. Nine of these pigs were then subjected to 5 mo of exercise training on a treadmill. After exercise training, we determined regional collateral and myocardial blood flow using radiolabeled microspheres. At autopsy, all animals had complete occlusion of the LCCA. Infarct size in the exercise-trained pigs was significantly less than in the sedentary pigs (5.9 +/- 1.0 vs. 11.7 +/- 1.0% of the left ventricle). The exercise-trained animals had a greater increase in collateral flow, 35.1 +/- 3.0 vs. 28.7 +/- 4.1 ml X min-1 X 100 g-1, in the noninfarcted jeopardized zone of the LCCA bed. The major findings of the study were the following: 1) chronic coronary artery stenosis progressing to occlusion stimulated development of the collateral circulation and salvaged tissue in the jeopardized myocardium of an animal model with sparse collaterals; 2) development of the collateral circulation and tissue salvage is increased by exercise training; 3) collaterals develop primarily in or near the ischemic zone; and 4) all collateral beds develop a circumferential flow gradient following occlusion.  相似文献   

18.
The current study investigates the hyperemic flow effects on heamodynamics parameters such as velocity, wall shear stress in 3D coronary artery models with and without stenosis. The hyperemic flow is used to evaluate the functional significance of stenosis in the current era. Patients CT scan data of having healthy and coronary artery disease was chosen for the reconstruction of 3D coronary artery models. The diseased 3D models of coronary artery shows a narrowing of >50% lumen area. Computational fluid dynamics was performed to simulate the hyperemic flow condition. The results showed that the recirculation zone was observed immediate to the stenosis and highest wall shear stress was observed across the stenosis. The decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding of hyperemic flow effect under both conditions.  相似文献   

19.
Coronary computed tomography angiography (CCTA) in combination with first-pass CT myocardial perfusion imaging (MPI) has a better diagnostic performance than CCTA alone, compared with invasive coronary angiography as the reference standard. The aim of this study was to investigate the additional diagnostic value of first-pass CT-MPI without stress for detecting hemodynamic significance of coronary stenosis, compared with invasive fractional flow reserve (FFR). We recruited 53 patients with suspected coronary artery disease undergoing both CCTA and first-pass CT-MPI without stress and invasive FFR, and 75 vessels were analyzed. We used the same raw data for CCTA and CT-MPI. First-pass CT-MPI was reconstructed by examining the diastolic signal densities as a bull’s eye map. Invasive FFR <0.8 was considered as positive. On per-vessel analysis, the area under the receiver operating characteristic curve for CCTA plus first-pass CT-MPI and CCTA alone was 0.81 (0.73–0.90) and 0.70 (0.61–0.81), respectively (P = 0.036). CCTA plus first-pass CT-MPI without stress showed 0.73 sensitivity, 0.74 specificity, 0.53 positive predictive value, and 0.87 negative predictive value for detecting hemodynamically significant coronary stenosis. First-pass CT-MPI without stress correctly reclassified 38% of CCTA false-positive vessels as true negative. First-pass CT-MPI without stress combined with CCTA demonstrated excellent diagnostic accuracy, compared with invasive FFR as the reference standard. This technique could complement CCTA for diagnosis of coronary artery disease.  相似文献   

20.

Background

The systolic forward travelling compression wave (sFCW) and diastolic backward travelling decompression waves (dBEW) predominantly accelerate coronary blood flow. The effect of a coronary stenosis on the intensity of these waves in the distal vessel is unknown. We investigated the relationship between established physiological indices of hyperemic coronary flow and the intensity of the two major accelerative coronary waves identified by Coronary Wave Intensity analysis (CWIA).

Methodology / Principal Findings

Simultaneous intracoronary pressure and velocity measurement was performed during adenosine induced hyperemia in 17 patients with pressure / Doppler flow wires positioned distal to the target lesion. CWI profiles were generated from this data. Fractional Flow Reserve (FFR) and Coronary Flow Velocity Reserve (CFVR) were calculated concurrently. The intensity of the dBEW was significantly correlated with FFR (R = -0.70, P = 0.003) and CFVR (R = -0.73, P = 0.001). The intensity of the sFCW was also significantly correlated with baseline FFR (R = 0.71, p = 0.002) and CFVR (R = 0.59, P = 0.01). Stenting of the target lesion resulted in a median 178% (interquartile range 55–280%) (P<0.0001) increase in sFCW intensity and a median 117% (interquartile range 27–509%) (P = 0.001) increase in dBEW intensity. The increase in accelerative wave intensity following PCI was proportionate to the baseline FFR and CFVR, such that stenting of lesions associated with the greatest flow limitation (lowest FFR and CFVR) resulted in the largest increases in wave intensity.

Conclusions

Increasing ischemia severity is associated with proportionate reductions in cumulative intensity of both major accelerative coronary waves. Impaired diastolic microvascular decompression may represent a novel, important pathophysiologic mechanism driving the reduction in coronary blood flow in the setting of an epicardial stenosis.  相似文献   