共查询到20条相似文献,搜索用时 0 毫秒
1.
Anterior cruciate ligament reconstruction (ACLR) restores joint stability following ACL injury but does not attenuate the heightened risk of developing knee osteoarthritis. Additionally, patellar tendon (PT) grafts incur a greater risk of osteoarthritis compared to hamstring grafts (HT). Aberrant gait biomechanics, including greater loading rates (i.e. impulsive loading), are linked to the development of knee osteoarthritis. However, the role of graft selection on walking gait biomechanics linked to osteoarthritis is poorly understood, thus the purpose of this study was to compare walking gait biomechanics between individuals with HT and PT grafts. Ninety-eight (74 PT; 24 HT) subjects with a history of ACLR performed walking gait at a self-selected speed from which the peak vertical ground reaction force (vGRF) during the first 50% of the stance phase and its instantaneous loading rate, peak internal knee extension and valgus moments, and peak knee flexion and varus angles were obtained. When controlling for time since ACLR and quadriceps strength, there were no differences in any kinetic or kinematic variables between graft types. While not significant, 44% of the PT cohort were identified as impulsive loaders (displaying a heelstrike transient in the majority of walking trials) compared to only 25% of the HT cohort (odds ratio = 2.3). This more frequent observation of impulsive loading may contribute to the greater risk of osteoarthritis with PT grafts. Future research is necessary to determine if impulsive loading and small magnitude differences between graft types contribute to osteoarthritis risk when extrapolated over thousands of steps per day. 相似文献
2.
A potential cause of non-contact anterior cruciate ligament (ACL) injury is landing on an extended knee. In line with this hypothesis, studies have shown that the ACL is elongated with decreasing knee flexion angle. Furthermore, at low flexion angles the patellar tendon is oriented to increase the anterior shear component of force acting on the tibia. This indicates that knee extension represents a position in which the ACL is taut, and thus may have an increased propensity for injury, particularly in the presence of excessive force acting via the patellar tendon. However, there is very little in vivo data to describe how patellar tendon orientation and ACL elongation interact during flexion. Therefore, this study measured the patellar tendon tibial shaft angle (indicative of the relative magnitude of the shear component of force acting via the patellar tendon) and ACL length in vivo as subjects performed a quasi-static lunge at varying knee flexion angles. Spearman rho rank correlations within each individual revealed that flexion angles were inversely correlated to both ACL length (rho = −0.94 ± 0.07, mean ± standard deviation, p < 0.05) and patellar tendon tibial shaft angle (rho = −0.99 ± 0.01, p < 0.05). These findings indicate that when the knee is extended, the ACL is both elongated and the patellar tendon tibial shaft angle is increased, resulting in a relative increase in anterior shear force on the tibia acting via the patellar tendon. Therefore, these data support the hypothesis that landing with the knee in extension is a high risk scenario for ACL injury. 相似文献
3.
The goal of this study was to develop a new implantable transducer for measuring anterior cruciate ligament (ACL) graft tension postoperatively in patients who have undergone ACL reconstructive surgery. A unique approach was taken of integrating the transducer into a femoral fixation device. To devise a practical in vivo calibration protocol for the fixation device transducer (FDT), several hypotheses were investigated: (1) The use of a cable versus the actual graft as the means for applying load to the FDT during calibration has no significant effect on the accuracy of the FDT tension measurements; (2) the number of flexion angles at which the device is calibrated has no significant effect on the accuracy of the FDT measurements; (3) the friction between the graft and femoral tunnel has no significant effect on measurement accuracy. To provide data for testing these hypotheses, the FDT was first calibrated with both a cable and a graft over the full range of flexion. Then graft tension was measured simultaneously with both the FDT on the femoral side and load cells, which were connected to the graft on the tibial side, as five cadaver knees were loaded externally. Measurements were made with both standard and overdrilled tunnels. The error in the FDT tension measurements was the difference between the graft tension measured by the FDT and the load cells. Results of the statistical analyses showed that neither the means of applying the calibration load, the number of flexion angles used for calibration, nor the tunnel size had a significant effect on the accuracy of the FDT. Thus a cable may be used instead of the graft to transmit loads to the FDT during calibration, thus simplifying the procedure. Accurate calibration requires data from just three flexion angles of 0, 45, and 90 deg and a curve fit to obtain a calibration curve over a continuous range of flexion within the limits of this angle group. Since friction did not adversely affect the measurement accuracy of the FDT, the femoral tunnel can be drilled to match the diameter of the graft and does not need to be overdrilled. Following these procedures, the error in measuring graft tension with the FDT averages less than 10 percent relative to a full-scale load of 257 N. 相似文献
4.
G R Wohl R C Shymkiw J R Matyas R Kloiber R F Zernicke 《Journal of applied physiology》2001,91(1):336-342
To understand more fully the early bone changes in an experimental model of osteoarthrosis, we quantified periarticular bone mineral density and bone mechanical properties in anterior cruciate ligament transected (ACLX) knee joints (4, 10, 32, and 39 wk post-ACLX) compared with contralateral joints and unoperated normal joints of skeletally mature animals. Maximal stress and energy were significantly reduced in ACLX cancellous bone from the medial femoral condyles at 4 wk postinjury. All mechanical properties (e.g., yield stress and elastic modulus) declined after 4 wk and were significantly reduced at 10 wk. ACLX bone mineral density was significantly reduced at all measured time points. Ash content was significantly reduced at 10 and 32 wk. Changes in the lateral condyles were similar but less pronounced than in the medial condyles. These bony changes accompanied the earliest articular cartilage molecular changes and preceded changes in the articular cartilage gross morphology. We suggest that these early changes in bone mechanical behavior contribute to the progression of osteoarthrosis and pathogenic changes in the joint. 相似文献
5.
Neuromuscular function after anterior cruciate ligament reconstruction with autologous semitendinosus-gracilis graft. 总被引:1,自引:0,他引:1
Glenn N Williams Lynn Snyder-Mackler Peter J Barrance Michael J Axe Thomas S Buchanan 《Journal of electromyography and kinesiology》2005,15(2):170-180
BACKGROUND: The quadrupled autologous semitendinosus-gracilis graft is the first choice of many orthopaedic surgeons when reconstructing the anterior cruciate ligament. The effect that this procedure has on voluntary muscle control remains unclear. The purpose of this study was to evaluate the effect that anterior cruciate ligament reconstruction with autologous semitendinosus-gracilis graft has on voluntary muscle control by assessing subjects' specificity of muscle action. METHODS: The voluntary muscle control of 10 people (seven males, three females) with acute, isolated ACL ruptures was assessed in the days prior to when they underwent anterior cruciate ligament reconstruction with quadrupled autologous semitendinosus-gracilis grafts and after they had returned to play in sports requiring quick changes of direction and jumping (approximately 6 months later). The experimental protocol included the use of an established target-matching protocol that requires subjects to produce and modulate force with fine control, electromyographic recordings from 11 muscles about the knee, and the use of circular statistics to calculate specificity indices that describe the degree of focus (specificity) associated with the activity pattern of each muscle. Data were analyzed by performing pre-surgery and post-return to sports side-to-side comparisons, as well as, pre-surgery to post-surgery ipsilateral comparisons. RESULTS: Diminished specificity of muscle action was observed in the activity patterns of most of the muscles of the subjects' anterior cruciate ligament deficient knees prior to surgery. The quadriceps muscles were particularly affected. Post-return to sports results indicated that voluntary muscle control had improved in most muscles. There was no significant difference in pre-surgery and post-return to sports semitendinosus and gracilis muscle control. The semimembranosus muscle displayed less specific muscle activity patterns following surgery, which may represent a compensation strategy for minor changes in neuromuscular function. CONCLUSIONS: Voluntary muscle control improved in most muscles following ACL reconstruction with semitendinosus-gracilis autografts. Semitendinosus and gracilis muscle control did not appear to be altered significantly by the procedure. 相似文献
6.
In this paper, we present a simple method of calculating deformation of an anterior cruciate ligament graft in combined elongation, bending and total twisting. We also report our results on these deformations for three types of ligament reconstruction in cadaver knees: two isometric reconstructions, using either a biological bone-patellar tendon-bone autograft or an artificial Trevira prosthesis, and modified over-the-top reconstruction with the prosthesis. The data show that the modified OTT technique produced elongation of the graft equivalent to that of the synthetic isometric technique, but significantly less than isometric reconstruction with the biological graft (p<0.05, ANOVA). Moreover, the grafts were subjected to bending and twisting. 相似文献
7.
8.
9.
《Redox report : communications in free radical research》2013,18(5):221-226
AbstractInterleukin (IL)-10 is an anti-inflammatory cytokine that suppresses pro-inflammatory cytokines. We previously demonstrated that supplementation with vitamins E and C ameliorated the increase in IL-10 immediately following anterior cruciate ligament (ACL) surgery in the absence of other cytokine perturbations. Since both oxidative stress and insulin-like growth factor-1 (IGF-1) can modulate IL-10 concentrations, the mechanisms for these changes warranted further investigation. Our objective was to evaluate the mechanism for the IL-10 decrease following ACL surgery. This study consisted of randomized, double-blind, placebo-controlled experimental design. Subjects were randomly assigned to daily supplementation with either: (i) antioxidants (AO; vitamins E [α-tocopherol] and C [ascorbic acid]; n = 10); or (ii) matching placebos (PL; n = 10). Supplementation started ~2 weeks prior to surgery (baseline) and concluded 3 months after surgery. Subjects provided six fasting blood samples at: (i) baseline; (ii) immediately pre-surgery (Pre); (iii) 90 min; (iv) 72 h; (v) 7 days; and (vi) 3 months post-surgery. α-Tocopherol, ascorbic acid, F2-isoprostane and IGF-1 concentrations were measured in each blood sample. At 90 min relative to other times, plasma F2-isoprostane concentrations were significantly (P < 0.05) elevated in both groups, while at 90 min IGF-1 was significantly (P < 0.05) lower in the AO compared to the PL group. The changes in IGF-1 at 90 min relative to baseline were correlated (P < 0.0001) with the changes in IL-10. The decrease in IL-10 observed in the AO group is likely dependent on the decrease IGF-1 since lipid peroxidation was unchanged between the two groups. 相似文献
10.
To determine which exercises do not overload the graft-fixation complex during intensive rehabilitation from reconstructive surgery of the anterior cruciate ligament (ACL), it would be useful to measure ACL graft loads during rehabilitative activities in vivo in humans. A previous paper by Ventura et al. (1998) reported on the design of an implantable transducer integrated into a femoral fixation device and demonstrated that the transducer could be calibrated to measure graft loads to better than 10 percent full-scale error in cadaveric knees. By measuring both the static and fatigue strengths of the transducer, the purpose of the present study was to determine whether the transducer could be safely implanted in humans without risk of structural failure. Eight devices were loaded to failure statically. Additionally, seven devices were tested using the up-and-down method to estimate the median fatigue strength at a life of 225,000 cycles. The average ultimate strength was 1856 +/- 74 N and the median fatigue strength was 441 N at a life of 225,000 cycles. The maximum graft load during normal daily activities is estimated to be 500 N and the 225,000 cycle life corresponds to that of the average healthy individual during a 12-week period. Considering that patients who have had an ACL reconstruction are less ambulatory than normal immediately following surgery and that biologic incorporation of the graft should be well developed by 12 weeks thus decreasing the load transmitted to the fixation device, the FDT can be safely implanted in humans without undue risk of structural failure. 相似文献
11.
Eziamaka C. Okafor Gangadhar M. Utturkar Margaret R. Widmyer Ermias S. Abebe Amber T. Collins Dean C. Taylor Charles E. Spritzer C.T. Moorman rd William E. Garrett Louis E. DeFrate 《Journal of biomechanics》2014
Altered joint motion has been thought to be a contributing factor in the long-term development of osteoarthritis after ACL reconstruction. While many studies have quantified knee kinematics after ACL injury and reconstruction, there is limited in vivo data characterizing the effects of altered knee motion on cartilage thickness distributions. Thus, the objective of this study was to compare cartilage thickness distributions in two groups of patients with ACL reconstruction: one group in which subjects received a non-anatomic reconstruction that resulted in abnormal joint motion and another group in which subjects received an anatomically placed graft that more closely restored normal knee motion. Ten patients with anatomic graft placement (mean follow-up: 20 months) and 12 patients with non-anatomic graft placement (mean follow-up: 18 months) were scanned using high-resolution MR imaging. These images were used to generate 3D mesh models of both knees of each patient. The operative and contralateral knee models were registered to each other and a grid sampling system was used to make site-specific comparisons of cartilage thickness. Patients in the non-anatomic graft placement group demonstrated a significant decrease in cartilage thickness along the medial intercondylar notch in the operative knee relative to the intact knee (8%). In the anatomic graft placement group, no significant changes were observed. These findings suggest that restoring normal knee motion after ACL injury may help to slow the progression of degeneration. Therefore, graft placement may have important implications on the development of osteoarthritis after ACL reconstruction. 相似文献
12.
《Journal of electromyography and kinesiology》2014,24(1):98-103
Greater hamstring musculotendinous stiffness is associated with lesser ACL loading mechanisms. Stiffness is enhanced via training, but previous investigations evaluated tendon rather than musculotendinous stiffness, and none involved the hamstrings. We evaluated the effects of isometric and isotonic training on hamstring stiffness and ACL loading mechanisms. Thirty-six healthy volunteers were randomly assigned to isometric, isotonic, and control groups. Isometric and isotonic groups completed 6 weeks of training designed to enhance hamstring stiffness. Stiffness, anterior tibial translation, and landing biomechanics were measured prior to and following the interventions. Hamstring stiffness increased significantly with isometric training (15.7%; p = 0.006), but not in the isotonic (13.5%; p = 0.089) or control (0.4%; p = 0.942) groups. ACL loading mechanisms changed in manners consistent with lesser loading, but these changes were not statistically significant. These findings suggest that isometric training may be an important addition to ACL injury prevention programs. The lack of significant changes in ACL loading mechanisms and effects of isotonic training were likely due to the small sample sizes per group and limited intervention duration. Future research using larger sample sizes and longer interventions is necessary to determine the effects of enhancing hamstring stiffness on ACL loading and injury risk. 相似文献
13.
U Bosch B Decker W Kasperczyk A Nerlich H J Oestern H Tscherne 《Journal of biomechanics》1992,25(8):821-830
In a sheep model the posterior cruciate ligament (PCL) was replaced by a patellar tendon autograft (PTAG) using the central one-third of the ipsilateral patellar tendon (PT). The sheep were sacrificed at 16, 26, 52 and 104 weeks postoperation. The PTAG, and, as controls, the contralateral PCL and PT were harvested. These were examined using biomechanical testing as well as light and transmission electron microscopy, including immunohistological techniques. The material properties (maximum stress, elastic modulus) were compared to the morphological features. The cellular distribution, the distribution of glycosaminoglycans (GAGs), the collagen fibril diameter and the occurrence of Type III collagen were studied. Prior to transplantation, the PTAG was shown to be superior in maximum stress (57.2 +/- 5.5 MPa vs 41.3 +/- 1.9 MPa) and elastic modulus (368.8 +/- 49.3 MPa vs 172.3 +/- 14.6 MPa) to the PCL. The early decline in material properties of the PTAG (maximum stress 22% and elastic modulus 42% of the control) after free grafting paralleled a cell- and capillary-rich PTAG tissue with remnants of necrosis and a poorly organized extracellular matrix. Two years after implantation, with progressive alignment of the tissue matrix, maximum stress and elastic modulus acquired approximately 60 and 70% of the control, respectively. However, there was also an evidence of degenerative changes characterized by acellular areas, loss of the normal bundling pattern of collagen fibers and abnormal accumulation of GAGs. Ultrastructurally, there was a predominant shift to thin collagen fibrils in the PTAG compared to PCL and PT, both consisting of thick and thin collagen fibrils. Thin fibrils were demonstrated to be, in part, split thick fibrils as well as newly formed fibrils. Most of these thin fibrils revealed a positive reaction with antibodies to Type III collagen. 相似文献
14.
There are many causes of lengthening of an anterior cruciate ligament soft-tissue graft construct (i.e., graft+fixation devices+bone), which can lead to an increase in anterior laxity. These causes can be due to plastic deformation andor an increase in elastic deformation. The purposes of this in vitro study were (1) to develop the methods to quantify eight causes (four elastic and four plastic) associated with the tibial and femoral fixations using Roentgen stereophotogrammetric analysis (RSA) and to demonstrate the usefulness of these methods, (2) to assess how well an empirical relationship between an increase in length of the graft construct and an increase in anterior laxity predicts two causes (one elastic and one plastic) associated with the graft midsubstance, and (3) to determine the increase in anterior tare laxity (i.e., laxity under the application of a 30 N anterior tare force) before the graft force reaches zero. Markers were injected into the tibia, femur, and graft in six cadaveric legs whose knees were reconstructed with single-loop tibialis grafts. To satisfy the first objective, legs were subjected to 1500 cycles at 14 Hz of 150 N anterior force transmitted at the knee. Based on marker 3D coordinates, equations were developed for determining eight causes associated with the fixations. After 1500 load cycles, plastic deformation between the graft and WasherLoc tibial fixation was the greatest cause with an average of 0.8+/-0.5 mm followed by plastic deformation between the graft and cross-pin-type femoral fixation with an average of 0.5+/-0.1 mm. The elastic deformations between the graft and tibial fixation and between the graft and femoral fixation decreased averages of 0.3+/-0.3 mm and 0.2+/-0.1 mm, respectively. The remaining four causes associated with the fixations were close to 0. To satisfy the remaining two objectives, after cyclic loading, the graft was lengthened incrementally while the 30 N anterior tare laxity, 150 N anterior laxity, and graft tension were measured. The one plastic cause and one elastic cause associated with the graft midsubstance were predicted by the empirical relationships with random errors (i.e., precision) of 0.9 mm and 0.5 mm, respectively. The minimum increase in 30 N anterior tare laxity before the graft force reached zero was 5 mm. Hence, each of the eight causes of an increase in the 150 N anterior laxity associated with the fixations can be determined with RSA as long as the overall increase in the 30 N anterior tare laxity does not exceed 5 mm. However, predicting the two causes associated with the graft using empirical relationships is prone to large errors. 相似文献
15.
Abebe ES Utturkar GM Taylor DC Spritzer CE Kim JP Moorman CT Garrett WE DeFrate LE 《Journal of biomechanics》2011,44(5):924-929
Achieving anatomical graft placement remains a concern in Anterior Cruciate Ligament (ACL) reconstruction. The purpose of this study was to quantify the effect of femoral graft placement on the ability of ACL reconstruction to restore normal knee kinematics under in vivo loading conditions. Two different groups of patients were studied: one in which the femoral tunnel was placed near the anterior and proximal border of the ACL (anteroproximal group, n=12) and another where the femoral tunnel was placed near the center of the ACL (anatomic group, n=10) MR imaging and biplanar fluoroscopy were used to measure in vivo kinematics in these patients during a quasi-static lunge. Patients with anteroproximal graft placement had up to 3.4mm more anterior tibial translation, 1.1mm more medial tibial translation and 3.7° more internal tibial rotation compared to the contralateral side. Patients with anatomic graft placement had motion that more closely replicated that of the intact knee, with anterior tibial translation within 0.8mm, medial tibial translation within 0.5mm, and internal tibial rotation within 1°. Grafts placed anteroproximally on the femur likely provide insufficient restraint to these motions due to a more vertical orientation. Anatomical femoral placement of the graft is more likely to reproduce normal ACL orientation, resulting in a more stable knee. Therefore, achieving anatomical graft placement on the femur is crucial to restoring normal knee function and may decrease the rates of joint degeneration after ACL reconstruction. 相似文献
16.
Eleftherios Kellis Evaggelos Karagiannidis Glykeria Patsika 《Computer methods in biomechanics and biomedical engineering》2013,16(10):1083-1089
The purpose of this study was to examine the moment-arm and cross-sectional area (CSA) of the patellar tendon (PT) and the hamstrings after anterior cruciate ligament (ACL) reconstruction. The right knee of five males who underwent ACL reconstruction with a PT graft and five age-matched controls was scanned using magnetic resonance image scans. Based on three-dimensional (3D) solids of the PT, CSAs and moment-arms of semitendinous (ST), biceps femoris (BF) long head and semimembranosus (SM) were estimated. Analysis of variance indicated no significant group differences in muscle moment-arms (p>0.05). 3D moment-arms of PT, ST and BF were significantly lower than the corresponding 2D values (p < 0.05). The ACL group displayed a significantly higher maximum BF CSA, a lower ST CSA (p < 0.05) but similar PT and SM CSAs compared with controls. It is concluded that any alterations in PT properties 1 year after harvesting do not affect knee muscle moment-arms compared with age-matched controls. Moment-arm estimation differed between 3D and 2D data, although it did not affect comparisons between ACL reconstruction group and controls. Design of rehabilitation programmes should take into consideration a potential alteration in hamstring morphology following surgery with a PT graft. 相似文献
17.
Lengthening of an anterior cruciate ligament (ACL) graft construct can occur as a result of lengthening at the sites of tibial and/or femoral fixation and manifests as an increase in anterior laxity. Although lengthening at the site of fixation has been measured for a variety of fixation devices, it is difficult to place these results in a clinical context because the mathematical relationship between lengthening of an ACL graft construct and anterior laxity is unknown. The purpose of our study was to determine empirically this relationship. Ten cadaveric knees were reconstructed with a double-looped tendon graft. With the knee in 25 degrees of flexion, the position of the proximal end of the graft inside the femoral tunnel was adjusted by moving the femoral fixation device until the anterior laxity at an applied anterior force of 134 N matched that of the intact knee. In random order, the graft construct was lengthened 1, 2, 3, 4, and 5 mm by moving the femoral fixation device distally along the femoral tunnel and anterior laxity was measured. The increase in the length of the graft construct was related to the increase in anterior laxity by a simple linear regression model. Lengthening the graft construct from 1 to 5 mm caused an equal increase in anterior laxity (slope=1.0 mmmm, r(2)=0.800, p<0.0001). Because an anterior laxity increase of 3 mm or greater in a reconstructed knee is considered unstable clinically and because many fixation devices in widespread use clinically allow 3 mm or greater of lengthening in in vitro tests, our empirical relationship indicates that lengthening at the site of fixation probably is an important cause of knee instability following ACL reconstructive surgery. Our empirical relation also indicates that an important criterion in the design of future fixation devices is that lengthening at the sites of fixation in in vitro tests should be limited to less than 3 mm. 相似文献
18.
19.
Benjamin Gantenbein Neha Gadhari Samantha CW Chan Sandro Kohl Sufian S Ahmad 《World journal of stem cells》2015,7(2):521-534
AIM: To investigate collagen patches seeded with mesenchymal stem cells(MSCs) and/or tenocytes(TCs) with regards to their suitability for anterior cruciate ligament(ACL) repair. METHODS: Dynamic intraligamentary stabilization utilizes a dynamic screw system to keep ACL remnants in place and promote biological healing, supplemented by collagen patches. How these scaffolds interact with cells and what type of benefit they provide has not yet been investigated in detail. Primary ACL-derived TCs and human bone marrow derived MSCs were seeded onto two different types of 3D collagen scaffolds, Chondro-Gide?(CG) and Novocart?(NC). Cells were seeded onto the scaffolds and cultured for 7 d either as a pure populations or as "premix" containing a 1:1 ratio of TCs to MSCs. Additionally, as controls, cells were seeded in monolayers and in co-cultures on both sides of porous high-density membrane inserts(0.4 μm). We analyzed the patches by real time polymerase chain reaction, glycosaminoglycan(GAG), DNA and hydroxyproline(HYP) content. To determine cell spreading and adherence in the scaffolds microscopic imaging techniques, i.e., confocal laser scanning microscopy(c LSM) and scanning electron microscopy(SEM), were applied.RESULTS: CLSM and SEM imaging analysis confirmed cell adherence onto scaffolds. The metabolic cell activity revealed that patches promote adherence and proliferation of cells. The most dramatic increase in absolute metabolic cell activity was measured for CG samples seeded with tenocytes or a 1:1 cell premix. Analysis of DNA content and c LSM imaging also indicated MSCs were not proliferating as nicely as tenocytes on CG. The HYP to GAG ratio significantly changed for the premix group, resulting from a slightly lower GAG content, demonstrating that the cells are modifying the underlying matrix. Real-time quantitativepolymerase chain reaction data indicated that MSCs showed a trend of differentiation towards a more tenogenic-like phenotype after 7 d.CONCLUSION: CG and NC are both cyto-compatible with primary MSCs and TCs; TCs seemed to perform better on these collagen patches than MSCs. 相似文献
20.
Tyler Barker Scott W. Leonard Roy H. Trawick Thomas B. Martins Carl R. Kjeldsberg Harry R. Hill Maret G. Traber 《Free radical biology & medicine》2009,46(5):599-606
Muscle atrophy commonly follows anterior cruciate ligament (ACL) injury and surgery. Proinflammatory cytokines can induce and exacerbate oxidative stress, potentiating muscle atrophy. The purpose of this study was to evaluate the influence of prior antioxidant (AO) supplementation on circulating cytokines following ACL surgery. A randomized, double-blind, placebo-controlled trial was conducted in men undergoing ACL surgery, who were randomly assigned to either: (1) AO (200 IU of vitamin E (50% d-alpha-tocopheryl acetate and 50% d-α-tocopherol) and 500 mg ascorbic acid), or (2) matching placebos (PL). Subjects took supplements twice daily for 2 weeks prior to and up to 12 weeks after surgery. Each subject provided five blood samples: (1) baseline (Bsl, prior to supplementation and ~2 weeks prior to surgery), (2) presurgery (Pre), (3) 90 min, (4) 72 h, and (5) 7 days postsurgery. Following surgery, inflammation and muscle damage increased in both groups, as assessed by increased circulating IL-6, C-reactive protein, and creatine kinase. During AO supplementation, plasma α-T and AA increased while γ-T concentrations decreased significantly (P < 0.05). At 90 min the AO group displayed a significant decrease in AA, an inverse correlation between AA and (interleukin) IL-8 (r2 = 0.50, P < 0.05), and a significantly lower IL-10 response than that of the PL group. IL-10 was significantly elevated at 90 min and 72 h in the PL group. In summary, our findings show that circulating inflammatory cytokines increase and AO supplementation attenuated the increase in IL-10 in patients post-ACL surgery. 相似文献