首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Usually the measurement of multi-segment foot and ankle complex kinematics is done with stationary motion capture devices which are limited to use in a gait laboratory. This study aimed to propose and validate a wearable system to measure the foot and ankle complex joint angles during gait in daily conditions, and then to investigate its suitability for clinical evaluations. The foot and ankle complex consisted of four segments (shank, hindfoot, forefoot, and toes), with an inertial measurement unit (3D gyroscopes and 3D accelerometers) attached to each segment. The angles between the four segments were calculated in the sagittal, coronal, and transverse planes using a new algorithm combining strap-down integration and detection of low-acceleration instants. To validate the joint angles measured by the wearable system, three subjects walked on a treadmill for five minutes at three different speeds. A camera-based stationary system that used a cluster of markers on each segment was used as a reference. To test the suitability of the system for clinical evaluation, the joint angle ranges were compared between a group of 10 healthy subjects and a group of 12 patients with ankle osteoarthritis, during two 50-m walking trials where the wearable system was attached to each subject. On average, over all joints and walking speeds, the RMS differences and correlation coefficients between the angular curves obtained using the wearable system and the stationary system were 1 deg and 0.93, respectively. Moreover, this system was able to detect significant alteration of foot and ankle function between the group of patients with ankle osteoarthritis and the group of healthy subjects. In conclusion, this wearable system was accurate and suitable for clinical evaluation when used to measure the multi-segment foot and ankle complex kinematics during long-distance walks in daily life conditions.  相似文献   

2.
The purposes of this study was to test a mechanism to reduce the knee adduction moment by testing the hypothesis that increased medio-lateral trunk sway can reduce the knee adduction moment during ambulation in healthy subjects, and to examine the possibility that increasing medio-lateral trunk sway can produce similar potentially adverse secondary gait changes previously associated with reduced knee adduction moments in patients with knee osteoarthritis. Nineteen healthy adults performed walking trials with normal and increased medio-lateral trunk sway at a self-selected normal walking speed. Standard gait analysis was used to calculate three-dimensional lower extremity joint kinematics and kinetics. Knee and hip adduction moments were lower (-65.0% and -57.1%, respectively) for the increased medio-lateral trunk sway trials than for the normal trunk sway trials. Knee flexion angle at heel-strike was 3 degrees higher for the increased than for the normal trunk sway trials. Knee and hip abduction moments were higher for the increased medio-lateral trunk sway trials, and none of the other variables differed between the two conditions. Walking with increased medio-lateral trunk sway substantially reduces the knee adduction moment during walking in healthy subjects without some of the adverse secondary effects such as increased axial loading rates at the major joints of the lower extremity. This result supports the potential of using gait retraining for walking with increased medio-lateral trunk sway as treatment for patients with degenerative joint disease such as medial compartment knee osteoarthritis.  相似文献   

3.
There is increasing interest in wearable sensor technology as a tool for rehabilitation applications in community or home environments. Recent studies have focused on evaluating inertial based sensing (accelerometers, gyroscopes, etc.) that provide only indirect measures of joint motion. Measurement of joint kinematics using flexible goniometry is more direct, and still popular in laboratory environments, but has received little attention as a potential tool for wearable systems. The aim of this study was to compare two goniometric devices: a traditional strain-gauge flexible goniometer, and a fiberoptic flexible goniometer, for measuring dynamic knee flexion/extension angles during activity of daily living: chair rise, and gait; and exercise: deep knee bends, against joint angles computed from a "gold standard" Vicon motion tracking system. Six young adults were recruited to perform the above activities in the lab while wearing a goniometer on each knee, and reflective markers for motion tracking. Kinematic data were collected simultaneously from the goniometers (one on each leg) and the motion tracking system (both legs). The results indicate that both goniometers were within 2-5 degrees of the Vicon angles for gait and chair rise. For some deep knee bend trials, disagreement with Vicon angles exceeded ten degrees for both devices. We conclude that both goniometers can record ADL knee movement faithfully and accurately, but should be carefully considered when high (>120?deg) knee flexion angles are required.  相似文献   

4.
A method for gait analysis using wearable acceleration sensors and gyro sensors is proposed in this work. The volunteers wore sensor units that included a tri-axis acceleration sensor and three single axis gyro sensors. The angular velocity data measured by the gyro sensors were used to estimate the translational acceleration in the gait analysis. The translational acceleration was then subtracted from the acceleration sensor measurements to obtain the gravitational acceleration, giving the orientation of the lower limb segments. Segment orientation along with body measurements were used to obtain the positions of hip, knee, and ankle joints to create stick figure models of the volunteers. This method can measure the three-dimensional positions of joint centers of the hip, knee, and ankle during movement. Experiments were carried out on the normal gait of three healthy volunteers. As a result, the flexion–extension (F–E) and the adduction–abduction (A–A) joint angles of the hips and the flexion–extension (F–E) joint angles of the knees were calculated and compared with a camera motion capture system. The correlation coefficients were above 0.88 for the hip F–E, higher than 0.72 for the hip A–A, better than 0.92 for the knee F–E. A moving stick figure model of each volunteer was created to visually confirm the walking posture. Further, the knee and ankle joint trajectories in the horizontal plane showed that the left and right legs were bilaterally symmetric.  相似文献   

5.
The purpose of this study was to examine how inducing fatigue of the 1) lumbar erector spinae and 2) cervical erector spinae (CES) muscles affected the ability to maintain head stability during walking. Triaxial accelerometers were attached to the head, upper trunk, and lower trunk to measure accelerations in the vertical, anterior-posterior, and mediolateral directions during walking. Using three accelerometers enabled two adjacent upper body segments to be defined: the neck segment and trunk segment. A transfer function was applied to root mean square acceleration, peak power, and harmonic data derived from spectral analysis of accelerations to quantify segmental gain. The structure of upper body accelerations were examined using measures of signal regularity and smoothness. The main findings were that head stability was only affected in the anterior-posterior direction, as accelerations of the head were less regular following CES fatigue. Furthermore, following CES fatigue, the central nervous system altered the attenuation properties of the trunk segment in the anterior-posterior direction, presumably to enhance head stability. Following lumbar erector spinae fatigue, the trunk segment had greater gain and increased regularity and smoothness of accelerations in the mediolateral direction. Overall, the results of this study suggest that erector spinae fatigue differentially altered segmental attenuation during walking, according to the level of the upper body that was fatigued and the direction that oscillations were attenuated. A compensatory postural response was not only elicited in the sagittal plane, where greater segmental attenuation occurred, but also in the frontal plane, where greater segmental gain occurred.  相似文献   

6.
The purpose of this study was to verify the performance of recently developed body-worn sensor packs against 3D motion analysis of trunk and lower-limb movements. Five sensor packs, each consisting of rate gyroscope and two 2-D accelerometers controlled by a microprocessor were attached to the trunk, thighs, and shanks of an able bodied subject. A 6-camera motion analysis system (MAS) recorded multiple trials of sit-to-stand movements and normal walking. Time domain signals from each sensor pack were significantly correlated (r = 0.90-0.99;p < 0.05) with a root mean square errors of less than 5 degrees when compared against the same limb angle measurements calculated by the MAS. These data demonstrate that these external sensor packs are accurate devices for measuring trunk and lower-limb sagittal plane orientation in real-time.  相似文献   

7.
This work presents a novel and extensive investigation of mathematical regression techniques, for the prediction of laboratory-type kinematic measurements during human gait, from wearable measurement devices, such as gyroscopes and accelerometers. Specifically, we examine the hypothesis of predicting the segmental angles of the legs (left and right foot, shank and thighs), from rotational foot velocities and translational foot accelerations. This first investigation is based on kinematic data emulated from motion-capture laboratory equipment. We employ eight established regression algorithms with different properties, ranging from linear methods and neural networks with polynomial support and expanded nonlinearities, to radial basis functions, nearest neighbors and kernel density methods. Data from five gait cycles of eight subjects are used to perform both inter-subject and intra-subject assessments of the prediction capabilities of each algorithm, using cross-validation resampling methods. Regarding the algorithmic suitability to gait prediction, results strongly indicate that nonparametric methods, such as nearest neighbors and kernel density based, are particularly advantageous. Numerical results show high average prediction accuracy (rho = 0.98/0.99, RMS = 5.63 degrees/2.30 degrees, MAD = 4.43 degrees/1.52 degrees for inter/intra-subject testing). The presented work provides a promising and motivating investigation on the feasibility of cost-effective wearable devices used to acquire large volumes of data that are currently collected only from complex laboratory environments.  相似文献   

8.
Repetitive exposures to altered gait and movement following lower-limb amputation (LLA) have been suggested to contribute to observed alterations in passive tissue properties and neuromuscular control in/surrounding the lumbar spine. These alterations, in turn, may affect the synergy between passive and active tissues during trunk movements. Eight males with unilateral LLA and eight non-amputation controls completed quasi-static trunk flexion–extension movements in seven distinct conditions of rotation in the transverse plane: 0° (sagittally-symmetric), ±15°, ±30°, and ±45° (sagittally-asymmetric). Electromyographic (EMG) activity of the bilateral lumbar erector spinae and lumbar kinematics were simultaneously recorded. Peak lumbar flexion and EMG-off angles were determined, along with the difference (“DIFF”) between these two angles and the magnitude of peak normalized EMG activities. Persons with unilateral LLA exhibited altered and asymmetric synergies between active and passive trunk tissues during both sagittally-symmetric and -asymmetric trunk flexion movements. Specifically, decreased and asymmetric passive contributions to trunk movements were compensated with increases in the magnitude and duration of active trunk muscle responses. Such alterations in trunk passive and active neuromuscular responses may result from repetitive exposures to abnormal gait and movement subsequent to LLA, and may increase the risk for LBP in this population.  相似文献   

9.
Measuring human gait is important in medicine to obtain outcome parameter for therapy, for instance in Parkinson’s disease. Recently, small inertial sensors became available which allow for the registration of limb-position outside of the limited space of gait laboratories. The computation of gait parameters based on such recordings has been the subject of many scientific papers. We want to add to this knowledge by presenting a 4-segment leg model which is based on inverse kinematic and Kalman filtering of data from inertial sensors. To evaluate the model, data from four leg segments (shanks and thighs) were recorded synchronously with accelerometers and gyroscopes and a 3D motion capture system while subjects (n = 12) walked at three different velocities on a treadmill. Angular position of leg segments was computed from accelerometers and gyroscopes by Kalman filtering and compared to data from the motion capture system. The four-segment leg model takes the stance foot as a pivotal point and computes the position of the remaining segments as a kinematic chain (inverse kinematics). Second, we evaluated the contribution of pelvic movements to the model and evaluated a five segment model (shanks, thighs and pelvis) against ground-truth data from the motion capture system and the path of the treadmill.ResultsWe found the precision of the Kalman filtered angular position is in the range of 2–6° (RMS error). The 4-segment leg model computed stride length and length of gait path with a constant undershoot of 3% for slow and 7% for fast gait. The integration of a 5th segment (pelvis) into the model increased its precision. The advantages of this model and ideas for further improvements are discussed.  相似文献   

10.
The purpose of this study was to determine the inter- and intra-examiner reliability, and stride-to-stride reliability, of an accelerometer-based gait analysis system which measured 3D accelerations of the upper and lower body during self-selected slow, preferred and fast walking speeds. Eight subjects attended two testing sessions in which accelerometers were attached to the head, neck, lower trunk, and right shank. In the initial testing session, two different examiners attached the accelerometers and performed the same testing procedures. A single examiner repeated the procedure in a subsequent testing session. All data were collected using a new wireless gait analysis system, which features near real-time data transmission via a Bluetooth network. Reliability for each testing condition (4 locations, 3 directions, 3 speeds) was quantified using a waveform similarity statistic known as the coefficient of multiple determination (CMD). CMD's ranged from 0.60 to 0.98 across all test conditions and were not significantly different for inter-examiner (0.86), intra-examiner (0.87), and stride-to-stride reliability (0.86). The highest repeatability for the effect of location, direction and walking speed were for the shank segment (0.94), the vertical direction (0.91) and the fast walking speed (0.91), respectively. Overall, these results indicate that a high degree of waveform repeatability was obtained using a new gait system under test-retest conditions involving single and dual examiners. Furthermore, differences in acceleration waveform repeatability associated with the reapplication of accelerometers were small in relation to normal motor variability.  相似文献   

11.
A prey's body orientation relative to a predator's approach path may affect risk of fleeing straight ahead. Consequently, prey often turn before fleeing. Relationships among orientation, turn, and escape angles and between these angles and predation risk have not been studied in terrestrial vertebrates and have rarely been studied in the field. Escape angles are expected to lead away from predators and be highly variable to avoid being predictable by predators. Using approach speed as a risk factor, we studied these issues in the zebra‐tailed lizard, Callisaurus draconoides. Lizards fled away from human simulated predators, but most did not flee straight away. Escape angles were variable, as expected under the unpredictability hypothesis, and had modes at nearly straight away (i.e., 0°) and nearly perpendicular to the predator's approach path (90°). The straight away mode suggests maximal distancing from the predator; the other mode suggests maintaining ability to monitor the predator or possibly an influence of habitat features such as obstacles and refuges that differ among directions. Turn angles were larger when orientation was more toward the predator, and escape angles were closer to straight away when turn angles were larger. Turning serves to reach a favorable fleeing direction. When orientation angle was more toward the predator, escape angle was unaffected, suggesting that turn angle compensates completely for increased risk of orientation toward the predator. When approached more rapidly, lizards fled more nearly straight away, as expected under greater predation risk. Turn angles were unrelated to approach speed.  相似文献   

12.
Biomechanical model assumptions affect the interpretation of the role of the muscle or joint moments to the segmental power estimated by induced acceleration analysis (IAA). We evaluated the effect of modeling the pelvis and trunk segments as two separate segments (8 SM) versus as a single segment (7 SM) on the segmental power, support of the body, knee and hip extension acceleration produced by the joint moments during the stance phase of normal walking. Significant differences were observed in the contribution of the stance hip abductor and extensor moments to support, ipsilateral knee and hip acceleration, and ipsilateral thigh and upper body power. The primary finding was that the role of the stance hip moment in generating ipsilateral thigh and upper body power differed based on degrees of freedom in the model. Secondarily, the magnitude of contributions also differed. For example, the hip abductor and extensor moments showed greater contribution to support, hip and knee acceleration in the 8 SM. IAA and segment power analysis are sensitive to the degrees of freedom between the pelvis and trunk. There is currently no gold standard by which to evaluate the accuracy of IAA predictions. However, modeling the pelvis and trunk as separate segments is closer to the anatomical architecture of the body. An 8 SM appears to be more appropriate for estimating the role of joint moments, particularly to motion of more proximal segments during normal walking.  相似文献   

13.
The purpose of this study was to evaluate gait retraining for reducing the knee adduction moment. Our primary objective was to determine whether subject-specific altered gaits aimed at reducing the knee adduction moment by 30% or more could be identified and adopted in a single session through haptic (touch) feedback training on multiple kinematic gait parameters. Nine healthy subjects performed gait retraining, in which data-driven models specific to each subject were determined through experimental trials and were used to train novel gaits involving a combination of kinematic changes to the tibia angle, foot progression and trunk sway angles. Wearable haptic devices were used on the back, knee and foot for real-time feedback. All subjects were able to adopt altered gaits requiring simultaneous changes to multiple kinematic parameters and reduced their knee adduction moments by 29-48%. Analysis of single parameter gait training showed that moving the knee medially by increasing tibia angle, increasing trunk sway and toeing in all reduced the first peak of the knee adduction moment with tibia angle changes having the most dramatic effect. These results suggest that individualized data-driven gait retraining may be a viable option for reducing the knee adduction moment as a treatment method for early-stage knee osteoarthritis patients with sufficient sensation, endurance and motor learning capabilities.  相似文献   

14.
15.
Inertial measurement units (IMUs) are integrated electronic devices that contain accelerometers, magnetometers and gyroscopes. Wearable motion capture systems based on IMUs have been advertised as alternatives to optical motion capture. In this paper, the accuracy of five different IMUs of the same type in measuring 3D orientation in static situations, as well as the calibration of the accelerometers and magnetometers within the IMUs, has been investigated. The maximum absolute static orientation error was 5.2°, higher than the 1° claimed by the vendor. If the IMUs are re-calibrated at the time of measurement with the re-calibration procedure described in this paper, it is possible to obtain an error of less than 1°, in agreement with the vendor's specifications (XSens Technologies B.V. 2005. Motion tracker technical documentation Mtx-B. Version 1.03. Available from: www.xsens.com).

The new calibration appears to be valid for at least 22 days providing the sensor is not exposed to high impacts. However, if several sensors are ‘daisy chained’ together changes to the magnetometer bias can cause heading errors of up to 15°. The results demonstrate the non-linear relationship between the vendor's orthogonality claim of < 0.1° and the accuracy of 3D orientation obtained from factory calibrated IMUs in static situations. The authors hypothesise that the high magnetic dip (64°) in our laboratory may have exacerbated the errors reported. For biomechanical research, small relative movements of a body segment from a calibrated position are likely to be more accurate than large scale global motion that may have an error of up to 9.8°.  相似文献   

16.
Wearable systems are becoming increasingly popular for gait assessment outside of laboratory settings. A single shoe-embedded sensor module can measure the foot progression angle (FPA) during walking. The FPA has important clinical utility, particularly in populations with knee osteoarthritis, as it is a target for biomechanical treatments. However, the validity and the day-to-day reliability of FPA measurement using wearable systems during over-ground walking has yet to be established. Two gait analysis sessions on 20 healthy adults were conducted. During both sessions, participants performed natural over-ground walking in a motion capture laboratory and on a 100 m linear section of outdoor athletics track. FPA was measured in the laboratory via marker trajectory data, while the sensor module measured FPA during the outdoor track walking. Validity was examined by comparing the laboratory- and sensor-measured average FPA. Day-to-day reliability was examined by comparing the sensor-measured FPA between the first and second gait analysis sessions. Average absolute error between motion capture and sensor measured FPA were 1.7° and 2.1° at session 1 and 2, respectively. A Bland and Altman plot indicated no systematic bias, with 95% limit of agreement widths of 4.2° – 5.1°. Intraclass correlation coefficient (ICC2k) analysis resulted in good to excellent validity (ICC = 0.89 – 0.91) and reliability (ICC = 0.95). Overall, the shoe-embedded sensor module is a valid and reliable method of measuring FPA during over-ground walking without the need for laboratory equipment.  相似文献   

17.
The kinematics information from imaging, if combined with optimization-based biomechanical models, may provide a unique platform for personalized assessment of trunk muscle forces (TMFs). Such a method, however, is feasible only if differences in lumbar spine kinematics due to differences in TMFs can be captured by the current imaging techniques. A finite element model of the spine within an optimization procedure was used to estimate segmental kinematics of lumbar spine associated with five different sets of TMFs. Each set of TMFs was associated with a hypothetical trunk neuromuscular strategy that optimized one aspect of lower back biomechanics. For each set of TMFs, the segmental kinematics of lumbar spine was estimated for a single static trunk flexed posture involving, respectively, 40° and 10° of thoracic and pelvic rotations. Minimum changes in the angular and translational deformations of a motion segment with alterations in TMFs ranged from 0° to 0.7° and 0 mm to 0.04 mm, respectively. Maximum changes in the angular and translational deformations of a motion segment with alterations in TMFs ranged from 2.4° to 7.6° and 0.11 mm to 0.39 mm, respectively. The differences in kinematics of lumbar segments between each combination of two sets of TMFs in 97% of cases for angular deformation and 55% of cases for translational deformation were within the reported accuracy of current imaging techniques. Therefore, it might be possible to use image-based kinematics of lumbar segments along with computational modeling for personalized assessment of TMFs.  相似文献   

18.
Wearable inertial measurement units (IMU) have been proposed to estimate GRF outside of specialized laboratories, however the precise influence of sensor placement error on accuracy is unknown. We investigated the influence of IMU position and orientation placement errors on GRF estimation accuracy. Methods: Kinematic data from twelve healthy subjects based on marker trajectories were used to simulate 1848 combinations of sensor position placement errors (range ± 100 mm) and orientation placement errors (range ± 25°) across eight body segments (trunk, pelvis, left/right thighs, left/right shanks, and left/right feet) during normal walking trials for baseline cases when a single sensor was misplaced and for the extreme cases when all sensors were simultaneously misplaced. Three machine learning algorithms were used to estimate GRF for each placement error condition and compared with the no placement error condition to evaluate performance. Results: Position placement errors for a single misplaced IMU reduced vertical GRF (VGRF), medio-lateral GRF (MLGRF), and anterior-posterior GRF (APGRF) estimation accuracy by up to 1.1%, 2.0%, and 0.9%, respectively and for all eight simultaneously misplaced IMUs by up to 4.9%, 6.0%, and 4.3%, respectively. Orientation placement errors for a single misplaced IMU reduced VGRF, MLGRF, and APGRF estimation accuracy by up to 4.8%, 7.3%, and 1.5%, respectively and for all eight simultaneously misplaced IMUs by up to 20.8%, 23.4%, and 12.3%, respectively. Conclusion: IMU sensor misplacement, particularly orientation placement errors, can significantly reduce GRF estimation accuracy and thus measures should be taken to account for placement errors in implementations of GRF estimation via wearable IMUs.  相似文献   

19.
We describe segment angles (trunk, thigh, shank, and foot) and joint angles (hip, knee, and ankle) for the hind limbs of bonobos walking bipedally ("bent-hip bent-knee walking," 17 sequences) and quadrupedally (33 sequences). Data were based on video recordings (50 Hz) of nine subjects in a lateral view, walking at voluntary speed. The major differences between bipedal and quadrupedal walking are found in the trunk, thigh, and hip angles. During bipedal walking, the trunk is approximately 33-41 degrees more erect than during quadrupedal locomotion, although it is considerably more bent forward than in normal human locomotion. Moreover, during bipedal walking, the hip has a smaller range of motion (by 12 degrees ) and is more extended (by 20-35 degrees ) than during quadrupedal walking. In general, angle profiles in bonobos are much more variable than in humans. Intralimb phase relationships of subsequent joint angles show that hip-knee coordination is similar for bipedal and quadrupedal walking, and resembles the human pattern. The coordination between knee and ankle differs much more from the human pattern. Based on joint angles observed throughout stance phase and on the estimation of functional leg length, an efficient inverted pendulum mechanism is not expected in bonobos.  相似文献   

20.
The purpose of this study was to determine the contribution of changes in amplitude and phasing of medio-lateral trunk sway to a change in the knee adduction moment when walking with increased medio-lateral trunk sway. Kinematic and kinetic data of walking trials with normal and with increased trunk sway were collected for 19 healthy volunteers using a standard motion analysis system. The relationship between the change in first peak knee adduction moment (ΔKAM) and change in trunk sway amplitude (ΔSA; difference between maximum contralateral trunk lean and maximum ipsilateral trunk lean) and phasing (SP; time of heel-strike relative to time of maximum contralateral and time of maximum ipsilateral trunk lean) was determined using nonlinear regression analysis. On average, subjects increased their SA by 9.7?±?3.6 deg (P?相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号