首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 419 毫秒
1.
The biomechanics of the patellofemoral (PF) joint is complex in nature, and the aetiology of such manifestations of PF instability as patellofemoral pain syndrome (PFPS) is still unclear. At this point, the particular factors affecting PFPS have not yet been determined. This study has two objectives: (1) The first is to develop an alternative geometric method using a three-dimensional (3D) registration technique and linear mapping to investigate the PF joint contact stress using an indirect measure: the depth of virtual penetration (PD) of the patellar cartilage surface into the femoral cartilage surface. (2) The second is to develop 3D PF joint models using the finite element analysis (FEA) to quantify in vivo cartilage contact stress and to compare the peak contact stress location obtained from the FE models with the location of the maximum PD. Magnetic resonance images of healthy and PFPS subjects at knee flexion angles of 15°, 30° and 45° during isometric loading have been used to develop the geometric models. The results obtained from both approaches demonstrated that the subjects with PFPS show higher PD and contact stresses than the normal subjects. Maximum stress and PD increase with flexion angle, and occur on the lateral side in healthy and on the medial side in PFPS subjects. It has been concluded that the alternative geometric method is reliable in addition to being computationally efficient compared with FEA, and has the potential to assess the mechanics of PFPS with an accuracy similar to the FEA.  相似文献   

2.
Patellofemoral pain is a common knee disorder with a multi-factorial etiology related to abnormal patellar tracking. Our hypothesis was that the pattern of three-dimensional rotation and translation of the patella induced by selective activation of individual quadriceps components would differ between subjects with patellofemoral pain and healthy subjects. Nine female subjects with patellofemoral pain and seven healthy female subjects underwent electrical stimulation to selectively activate individual quadriceps components (vastus medialis obliquus, VMO; vastus medialis lateralis, VML; vastus lateralis, VL) with the knee at 0° and 20° flexion, while three-dimensional patellar tracking was recorded. Normalized direction of rotation and direction of translation characterized the relative amplitudes of each component of patellar movement. VMO activation in patellofemoral pain caused greater medial patellar rotation (distal patellar pole rotates medially in frontal plane) at both knee positions (p<0.01), and both VMO and VML activation caused increased anterior patellar translation (p<0.001) in patellofemoral pain compared to healthy subjects at 20° knee flexion. VL activation caused more lateral patellar translation (p<0.001) in patellofemoral pain compared to healthy subjects. In healthy subjects the 3-D mechanical action of the VMO is actively modulated with knee flexion angle while such modulation was not observed in PFP subjects. This could be due to anatomical differences in the VMO insertion on the patella and medial quadriceps weakness. Quantitative evaluation of the influence of individual quadriceps components on patellar tracking will aid understanding of the knee extensor mechanism and provide insight into the etiology of patellofemoral pain.  相似文献   

3.
The mechanical environment during stair climbing has been associated with patellofemoral pain, but the contribution of loading to this condition is not clearly understood. It was hypothesized that the loading conditions during stair climbing induce higher patellofemoral pressures, a more lateral force distribution on the trochlea and a more lateral shift and tilt of the patella compared to walking at early knee flexion. Optical markers for kinematic measurements were attached to eight cadaveric knees, which were loaded with muscle forces at instances of walking and stair climbing cycles at 12° and 30° knee flexion. Contact mechanics were determined using a pressure sensitive film. At 12° knee flexion, stair climbing loads resulted in higher peak pressure (p=0.012) than walking, more lateral force distribution (p=0.012) and more lateral tilt (p=0.012), whilst mean pressure (p=0.069) and contact area (p=0.123) were not significantly different. At 30° knee flexion, although stair climbing compared to walking loads resulted in significantly higher patellofemoral mean (p=0.012) and peak pressures (p=0.012), contact area (p=0.025), as well as tilt (p=0.017), the medial–lateral force distribution (p=0.674) was not significantly different. No significant differences were observed in patellar shift between walking and stair climbing at either 12° (p=0.093) or 30° (p=0.575) knee flexion. Stair climbing thus leads to more challenging patellofemoral contact mechanics and kinematics than level walking at early knee flexion. The increase in patellofemoral pressure, lateral force distribution and lateral tilt during stair climbing provides a possible biomechanical explanation for the patellofemoral pain frequently experienced during this activity.  相似文献   

4.
The iliotibial band (ITB) has an important role in knee mechanics and tightness can cause patellofemoral maltracking. This study investigated the effects of increasing ITB tension on knee kinematics. Nine fresh-frozen cadaveric knees had the components of the quadriceps loaded with 175 N. A Polaris optical tracking system was used to acquire joint kinematics during extension from 100° to 0° flexion. This was repeated after the following ITB loads: 30, 60 and 90 N. There was no change with 30 N load for patellar translation. On average, at 60 and 90 N, the patella translated laterally by 0.8 and 1.4 mm in the mid flexion range compared to the ITB unloaded condition. The patella became more laterally tilted with increasing ITB loads by 0.7°, 1.2° and 1.5° for 30, 60 and 90 N, respectively. There were comparable increases in patellar lateral rotation (distal patella moves laterally) towards the end of the flexion cycle. Increased external rotation of the tibia occurred from early flexion onwards and was maximal between 60° and 75° flexion. The increase was 5.2°, 9.5° and 13° in this range for 30, 60 and 90 N, respectively. Increased tibial abduction with ITB loads was not observed. The combination of increased patellar lateral translation and tilt suggests increased lateral cartilage pressure. Additionally, the increased tibial external rotation would increase the Q angle. The clinical consequences and their relationship to lateral retinacular releases may be examined, now that the effects of a tight ITB are known.  相似文献   

5.
The aim of this study was to quantify the tibio-femoral contact point (CP) locations in healthy and osteoarthritic (OA) subjects during a weight-bearing squat using stand-alone biplanar X-ray images.Ten healthy and 9 severe OA subjects performed quasi-static squats. Bi-planar X-ray images were recorded at 0°, 15°, 30°, 45°, and 70° of knee flexion. A reconstruction/registration process was used to create 3D models of tibia, fibula, and femur from bi-planar X-rays and to measure their positions at each posture. A weighted centroid of proximity algorithm was used to calculate the tibio-femoral CP locations. The accuracy of the reconstruction/registration process in measuring the quasi-static kinematics and the contact parameters was evaluated in a validation study.The quasi-static kinematics data revealed that in OA knees, adduction angles were greater (p<0.01), and the femur was located more medially relative to the tibia (p<0.01). Similarly, the average CP locations on the medial and lateral tibial plateaus of the OA patients were shifted (6.5±0.7 mm; p<0.01) and (9.6±3.1 mm; p<0.01) medially compared to the healthy group. From 0° to 70° flexion, CPs moved 8.1±5.3 mm and 8.9±5.3 mm posteriorly on the medial and lateral plateaus of healthy knees; while in OA joints CPs moved 10.1±8.4 mm and 3.6±2.8 mm posteriorly. The average minimum tibio-femoral bone-to-bone distances of the OA joints were lower in both compartments (p<0.01).The CPs in the OA joints were located more medially and displayed a higher ratio of medial to lateral posterior translations compared to healthy joints.  相似文献   

6.
A common rehabilitation strategy for patellofemoral pain syndrome (PFPS), which lacks scientific evidence, includes pulling the patella medially with tape to reduce pain and increase the vastus medialis oblique (VMO) muscle activity. The purpose of this study was to examine the effect of various patellar taping procedures on force production, EMG activity of the VMO and vastus lateralis (VL) muscles, and perceived pain experienced by 30 women (27.3 +/- 1.53), half diagnosed with PFPS. The perceived pain, force, and EMG of the VMO and VL, were recorded while subjects performed maximal isokinetic leg presses at 30 degrees /s for each of the following patellar taping conditions: no tape (control), no glide (placebo), medial and lateral glide (experimental). The medial and placebo procedures significantly (P < 0.01) reduced perceived pain (70-80%) in PFPS subjects. Although patellar taping did not influence leg press force (P > 0.05), it increased the VMO activity and decreased the VL activity in PFPS subjects but had the opposite effect in healthy subjects. The findings suggest that taping the patella medially can contribute positively to PFPS rehabilitation. Because the medial glide and placebo taping conditions had similar effects, it is proposed that the benefits of patellar taping are not due to a change in patellar position but rather due to enhanced support of the patellofemoral ligaments and/or pain modulation via cutaneous stimulation.  相似文献   

7.
Studies of three-dimensional patellar kinematics done with little or no applied load may not accurately reflect kinematics at physiological load levels, and may provide different results to those acquired with greater applied loads or in physiologic weightbearing. We report the effect of load magnitude on three-dimensional patellar kinematics (flexion, spin and tilt; proximal, lateral and anterior translation) using a validated, sequential static, MRI-based method. Ten healthy subjects loaded their study knee to 0% (no load), 15% and 30% bodyweight (BW) using a custom designed loading rig. Differences between loading levels were determined as a function of knee flexion for each kinematic parameter using linear hierarchical random-effects models. Quadratic and random slope terms were included in the models when significant. We found that the patellae flexed less with knee flexion at 30% BW load compared to 0% BW load (p<0.001) and 15% BW (p=0.004) load. The patellae showed a slight medial tilt with knee flexion at 30% BW load which was significantly less than the medial tilt seen at 0% BW load (p=0.017) and 15% BW load (p=0.043) with knee flexion. Small but statistically significant differences were also observed for proximal and anterior translation; the patellae were in a more proximal and posterior position at 30% BW load than at 0% BW load (p=0.010 and p=0.005, respectively) and 15% BW load (p<0.001 and p=0.029, respectively). Since differences in three-dimensional patellar kinematics were observed between loading levels, magnitudes of prescribed loads must be considered when designing studies and comparing results between studies.  相似文献   

8.
Patellofemoral osteoarthritis and its potential precursor patellofemoral pain syndrome (PFPS) are common, costly, and debilitating diseases. PFPS has been shown to be associated with altered patellofemoral joint mechanics; however, an actual variation in joint contact stresses has not been established due to challenges in accurately quantifying in vivo contact kinematics (area and location). This study developed and validated a method for tracking dynamic, in vivo cartilage contact kinematics by combining three magnetic resonance imaging (MRI) techniques, cine-phase contrast (CPC), multi-plane cine (MPC), and 3D high-resolution static imaging. CPC and MPC data were acquired from 12 healthy volunteers while they actively extended/flexed their knee within the MRI scanner. Since no gold standard exists for the quantification of in vivo dynamic cartilage contact kinematics, the accuracy of tracking a single point (patellar origin relative to the femur) represented the accuracy of tracking the kinematics of an entire surface. The accuracy was determined by the average absolute error between the PF kinematics derived through registration of MPC images to a static model and those derived through integration of the CPC velocity data. The accuracy ranged from 0.47 mm to 0.77 mm for the patella and femur and from 0.68 mm to 0.86 mm for the patellofemoral joint. For purely quantifying joint kinematics, CPC remains an analytically simpler and more accurate (accuracy <0.33 mm) technique. However, for application requiring the tracking of an entire surface, such as quantifying cartilage contact kinematics, this combined imaging approach produces accurate results with minimal operator intervention.  相似文献   

9.
Recent studies have determined a seemingly consistent feature of able-bodied level ground walking, termed the roll-over shape, which is the effective rocker (cam) shape that the lower limb system conforms to between heel contact and contralateral heel contact during walking (first half of the gait cycle). The roll-over shape has been found to be largely unaffected by changes in walking speed, load carriage, and shoe heel height. However, it is unclear from previous studies whether persons are controlling their lower limb systems to maintain a consistent roll-over shape or whether this finding is a byproduct of their attempt to keep ankle kinematic patterns similar during the first half of the gait cycle. We measured the ankle–foot roll-over shapes and ankle kinematics of eleven able-bodied subjects while walking on rocker shoes of different radii. We hypothesized that the ankle flexion patterns during single support would change to maintain a similar roll-over shape. We also hypothesized that with decrease in rocker shoe radii, the difference in ankle flexion between the end and beginning of single support would decrease. Our results supported these hypotheses. Ankle kinematics were changed significantly during walking with the different rocker shoe radii (p<0.001), while ankle–foot roll-over shape radii (p=0.146) and fore–aft position (p=0.132) were not significantly affected. The results of this study have direct implications for designers of ankle–foot prostheses, orthoses, walking casts/boots, and rocker shoes. The results may also be relevant to researchers studying control of human movements.  相似文献   

10.
The purpose of this study was to test the hypothesis that the musculotendon moment arm length is affected by the muscle anatomical cross-sectional area. The moment arm length of the triceps brachii (TB) muscle at 30°, 50°, 70°, 90°, 110° elbow flexion positions was measured in sagittal magnetic resonance images (MRI) of 18 subjects as the perpendicular distance between the center of the pulley of the humerus to the line through the center of the TB tendon. The moment arm increased as the elbow flexion angle decreased, from 1.74±0.13 cm at 110° to 2.39±0.14 cm at 30°. The maximal anatomical cross-sectional area of the TB muscle was significantly correlated with the moment arms at all joint positions (r=0.545–0.803, p<0.05). Furthermore, the circumference of the upper arm was also significantly correlated with the moment arms at all joint positions, except for 70° (r=0.504–0.702, p<0.05). These results indicate that the moment arm length of the TB muscle is affected by the muscle anatomical cross-sectional area.  相似文献   

11.
A detailed 3D anatomical model of the patellofemoral joint was developed to study the tracking, force, contact and stability characteristics of the joint. The quadriceps was considered to include six components represented by 15 force vectors. The patellar tendon was modeled using four bundles of viscoelastic tensile elements. Each of the lateral and medial retinaculum was modeled by a three-bundle nonlinear spring. The femur and patella were considered as rigid bodies with their articular cartilage layers represented by an isotropic viscoelastic material. The geometrical and tracking data needed for model simulation, as well as validation of its results, were obtained from an in vivo experiment, involving MR imaging of a normal knee while performing isometric leg press against a constant 140 N force. The model was formulated within the framework of a rigid body spring model and solved using forth-order Runge-Kutta, for knee flexion angles between zero and 50 degrees. Results indicated a good agreement between the model predictions for patellar tracking and the experimental results with RMS deviations of about 2 mm for translations (less than 0.7 mm for patellar mediolateral shift), and 4 degrees for rotations (less than 3 degrees for patellar tilt). The contact pattern predicted by the model was also consistent with the results of the experiment and the literature. The joint contact force increased linearly with progressive knee flexion from 80 N to 210 N. The medial retinaculum experienced a peak force of 18 N at full extension that decreased with knee flexion and disappeared entirely at 20 degrees flexion. Analysis of the patellar time response to the quadriceps contraction suggested that the muscle activation most affected the patellar shift and tilt. These results are consistent with the recent observations in the literature concerning the significance of retinaculum and quadriceps in the patellar stability.  相似文献   

12.
Many studies have reported strength gains in older adults following high-intensity resistance training. However, the muscle contraction types examined have been primarily isometric (static) or concentric (CONC; shortening). Less is known about how eccentric (ECC) strength in older adults responds to training or about the efficacy of ECC contractions as training stimuli in these subjects, even though muscle contractions of this type are performed in most training regimens and daily physical activities. In this study, 15 physically active, healthy older women [68 (5) years; mean (SD)] completed an 8-week resistance training program of two sessions per week. Training consisted of three sets of eight repetitions of CONC ankle plantar flexion (PF) and ECC dorsiflexion (DF), at greater than 80% of the initial peak torque, in a standing position only. Subjects were tested in standing and supine positions for: (1) strength over a range of 10° DF to 20° PF for both CONC and ECC; DF and PF (2) passive resistive torque of the plantar flexors at 6°/s; and (3) DF and PF rate of torque development. All strength testing and training was done at 30°/s. Significant increases (P < 0.01) were found for both CONC DF (↑30%) and ECC DF (↑17%) peak torque in the standing position. No significant changes occurred for DF strength as measured with the subjects in the supine position, PF strength in either position, passive resistive torque, or rate of torque development. In summary, strength gains occurred only in the dorsiflexors, which were trained using ECC contractions. Improvements in DF strength were specific to the position of training, which has implications for the transferability of strength gains to functional tasks such as maintaining gait. Accepted: 17 January 1997  相似文献   

13.
This study investigated changes in patellofemoral (PF) kinematics for different loading configurations of the quadriceps muscle: single line of action (SL), physiological-based multiple lines of action (ML), weak vastus medialis (WVM), and weak vastus lateralis (WVL). Fourteen cadaveric knees were flexed from 15° to 120° knee flexion using a loading rig with the ability to load different heads of the quadriceps and hamstring muscles in their anatomical orientation. PF rotation in the sagittal plane) and medial lateral translation were significantly different (p<0.05) for SL and ML, with maximum differences of 2.8° and 0.9 mm at 15° and 45° knee flexion, respectively. Compared to the ML, the WVM induced an average lateral shift of 1.5 mm and an abduction rotation of 0.8°, whereas a 0.9 mm medial shift and 0.6° adduction rotation was seen when simulating a WVL. The difference in the sagittal plane resultant force orientation of 26° between SL and ML was the major contributor to the change in PF rotation in the sagittal plane, while the difference in the frontal plane resultant force orientation of both the WVM and WVL from the ML (17° medial and 8° lateral, respectively) were the primary reasons for the change in PF frontal plane rotation and medial lateral translation. The two PF kinematic were significantly different from the ML for WVM and WVL (p<0.05). The results suggest that quadriceps muscle loading configuration can have a large influence on PF kinematics during full extension but less in deeper flexion. Therefore, using quadriceps single line loading for simulating activities with low flexion angles might not be sufficient to accurately replicate the physiological condition.  相似文献   

14.
The objective of this study was to determine the magnitude and phasic relationship of the torso muscles in rotation–flexion of varying degree of asymmetries of the trunk. Nineteen normal young subjects (7 males and 12 females) were stabilized on a posture stabilizing platform and instructed to assume a flexed and right rotated posture. A combination 20°, 40° and 60° of rotation and 20°, 40° and 60° of flexion resulted in nine postures. These postures were assumed in a random order. The subjects were asked to exert their maximal voluntary isometric contraction (MVC) in the plane of rotation of the posture assumed for a period of 5 s. The surface EMG from the external and internal obliques, rectus abdominis, latissimus dorsi and erector spinae at the 10th thoracic and 3rd lumbar vertebral levels was recorded. The abdominal muscles had the least response at 40° of flexion, the dorsal muscles had the highest magnitude.With increasing right rotation, the left external oblique continued to decrease its activity. The ANOVA revealed that rotation and muscles had a significant main effect on normalized peak EMG (p < 0.02) in both genders. There was a significant interaction between rotation and flexion in both genders (p < 0.02) and rotation and muscle in females. The erector spinae activity was highest at 40° flexion, due to greater mechanical disadvantage and having not reached the state of flexion–relaxation. The abdominal muscle activity declined with increasing asymmetry, due to the decreasing initial muscle length. The EMG activity was significantly affected by rotation than flexion (p < 0.02).  相似文献   

15.
Patellofemoral (PF)-related pathologies, including joint laxity, patellar maltracking, cartilage degradation and anterior knee pain, affect nearly 25% of the population. Researchers have investigated the influence of articular geometry on kinematics and contact mechanics in order to gain insight into the etiology of these conditions. The purpose of the current study was to create a three-dimensional statistical shape model of the PF joint and to characterize relationships between PF shape and function (kinematics and contact mechanics). A statistical shape model of the patellar and femoral articular surfaces and their relative alignment was developed from magnetic resonance images. Using 15 shape parameters, the model characterized 97% of the variation in the training set. The first three shape modes primarily described variation in size, patella alta-baja and depth of the sulcus groove. A previously verified finite element model was used to predict kinematics and contact mechanics for each subject. Combining the shape and joint mechanics data, a statistical shape-function model was developed that established quantitative relations of how changes in the shape of the PF joint influence mechanics. The predictive capability of the shape-function model was evaluated by comparing statistical model and finite element predictions, resulting in kinematic root mean square errors of less than 3° and 2.5 mm. The key results of the study are dually in the implementation of a novel approach linking statistical shape and finite element models and the relationships elucidated between PF articular geometry and mechanics.  相似文献   

16.
The purpose of this study was to quantify strain and elongation of the long head of the biceps femoris (BFlh) and the semitendinosus (ST) tendon/aponeurosis. Forty participants performed passive knee extension trials from 90° of knee flexion to full extension (0°) followed by ramp isometric contractions of the knee flexors at 0°, 45° and 90° of knee flexion. Two ultrasound probes were used to visualize the displacement of BFlh and ST tendon/aponeurosis. Three-way analysis of variance designs indicated that: (a) Tendon/aponeurosis (passive) elongation and strain were higher for the BFlh than the ST as the knee was passively extended (p < 0.05), (b) contraction at each angular position was accompanied by a smaller BFlh tendon/aponeurosis (active) strain and elongation than the ST at higher levels of effort (p < 0.05) and (c) combined (passive and active) strain was significantly higher for the BFlh than ST during ramp contraction at 0° but the opposite was observed for the 45° and 90° flexion angle tests (p < 0.05). Passive elongation of tendon/aponeurosis has an important effect on the tendon/aponeurosis behavior of the hamstrings and may contribute to a different loading of muscle fibers and tendinous tissue between BFlh and ST.  相似文献   

17.
Complications in the patellofemoral (PF) joint of patients with total knee replacements include patellar subluxation and dislocation, and remain a cause for revision. Kinematic measurements to assess these complications and evaluate implant designs require the accuracy of dynamic stereo-radiographic systems with 3D-2D registration techniques. While tibiofemoral kinematics are typically derived by tracking metallic implants, PF kinematic measurements are difficult as the patellar implant is radiotransparent and a representation of the resected patella bone requires either pre-surgical imaging and precise implant placement or post-surgical imaging. Statistical shape models (SSMs), used to characterize anatomic variation, provide an alternative means to obtain the representation of the resected patella for use in kinematic tracking. Using a virtual platform of a stereo-radiographic system, the objectives of this study were to evaluate the ability of an SSM to predict subject-specific 3D implanted patellar geometries from simulated 2D image profiles, and to formulate an effective data collection methodology for PF kinematics by considering accuracy for a variety of patient pose scenarios. An SSM of the patella was developed for 50 subjects and a leave-one-out approach compared SSM-predicted and actual geometries; average 3D errors were 0.45 ± 0.07 mm (mean ± standard deviation), which is comparable to the accuracy of traditional segmentation. Further, initial imaging of the patella in five unique stereo radiographic perspectives yielded the most accurate representation. The ability to predict the remaining patellar geometry of the implanted PF joint with radiographic images and SSM, instead of CT, can reduce radiation exposure and streamline in vivo kinematic evaluations.  相似文献   

18.
A finite element analysis (FEA) modeling technique has been developed to characterize how varying the orientation of the patellar tendon influences the patellofemoral pressure distribution. To evaluate the accuracy of the technique, models were created from MRI images to represent five knees that were previously tested in vitro to determine the influence of hamstrings loading on patellofemoral contact pressures. Hamstrings loading increased the lateral and posterior orientation of the patellar tendon. Each model was loaded at 40°, 60°, and 80° of flexion with quadriceps force vectors representing the experimental loading conditions. The orientation of the patellar tendon was represented for the loaded and unloaded hamstrings conditions based on experimental measures of tibiofemoral alignment. Similar to the experimental data, simulated loading of the hamstrings within the FEA models shifted the center of pressure laterally and increased the maximum lateral pressure. Significant (p < 0.05) differences were identified for the center of pressure and maximum lateral pressure from paired t-tests carried out at the individual flexion angles. The ability to replicate experimental trends indicates that the FEA models can be used for future studies focused on determining how variations in the orientation of the patellar tendon related to anatomical or loading variations or surgical procedures influence the patellofemoral pressure distribution.  相似文献   

19.
Patellofemoral pain syndrome (PFPS) is one of the most common, yet misunderstood, knee pathologies. PFPS is thought to result from abnormal patella tracking caused from altered neuromuscular control. Researchers have investigated neuromuscular influences from the gluteus medius (GM), vastus medialis (VM), and vastus lateralis (VL) but with inconsistent findings. A reason for these discrepancies may be from varying methodology. The purpose of this study was to determine the reliability of electromyographic (EMG) methods used to assess amplitudes and timing differences of the GM, VM, and VL in subjects with PFPS. Seven females with PFPS participated. GM, VM, and VL activity was assessed during the stance phase of a stair descent task on two separate occasions. Amplitudes during the different intervals of stance were recorded and expressed as a percent of each muscle’s maximum voluntary isometric contraction. Muscle onsets at the beginning of stair descent were also determined. VM–GM, VL–GM, and VL–VM onset timing differences were quantified. Intraclass correlation coefficients (ICCs) and standard errors of measurement (SEMs) were calculated to assess between-day reliability. Most EMG measures had acceptable reliability (ICC3,5 ? 0.70). Although some measures had moderate reliability (ICC < 0.70), they had low SEMs, which suggested high measurement precision. These findings support using these methods for examining neuromuscular activity in subjects with PFPS.  相似文献   

20.
The purpose of this study was to determine the stability and accuracy of active knee joint velocity replication methods in healthy subjects. We used a repeated measures design with 14 healthy volunteers. Measures of velocity replication were performed in two ranges of knee joint flexion (0°–30° and 60°–90°), across four testing velocities (5, 10, 15, and 30°/s) in two movement directions (flexion and extension). Statistical analysis included intraclass correlation coefficients (ICCs; 2, k) and associated standard error of the measures calculated between day 1 and 2. We performed z-tests between all possible combinations of ICC pairs using Fisher’s Z transformations to determine if any significant differences existed between observed ICCs. We also calculated correlation ratios (η2) to explain the source of variability in the calculated ICCs. To assess measurement accuracy, we calculated constant error and absolute error between criterion and replication velocities. Results on ICCs and standard error of the measurements (SEMs) ranged from r = ?0.44 ± 7.00 to 0.88 ± 0.72°/s. Calculated z-tests indicated six paired ICCs were significantly different (?p < 0.1). In all six pairs, the faster test velocity had a lower ICC magnitude. The η2 calculations demonstrated that inconsistent performance between day 1 and 2 caused the low ICC magnitudes observed with faster testing velocities. Significantly more absolute error occurred at 30 and 15°/s compared with 5°/s. Significantly less constant error was observed for 30°/s compared with 15°/s. A significant direction by range of motion interaction indicated less constant error for flexion movements in the 60°–90° range of motion (ROM) as compared with extension movements in either ROM. Healthy individuals could actively replicate slower criterion velocities in the mid and end ranges of knee joint motion in both movement directions with an acceptable amount of consistency and accuracy. The data support the use of velocity replication in future investigations on proprioceptive function.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号