首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, we developed an approach for prosthetic foot design incorporating motion analysis, mechanical testing and computer analysis. Using computer modeling and finite element analysis, a three-dimensional (3D), numerical foot model of the solid ankle cushioned heel (SACH) foot was constructed and analyzed based upon loading conditions obtained from the gait analysis of an amputee and validated experimentally using mechanical testing. The model was then used to address effects of viscoelastic heel performance numerically. This is just one example of the type of parametric analysis and design enabled by this approach. More importantly, by incorporating the unique gait characteristics of the amputee, these parametric analyses may lead to prosthetic feet more appropriately representing a particular user's needs, comfort and activity level.  相似文献   

2.

In this study, we developed an approach for prosthetic foot design incorporating motion analysis, mechanical testing and computer analysis. Using computer modeling and finite element analysis, a three-dimensional (3D), numerical foot model of the solid ankle cushioned heel (SACH) foot was constructed and analyzed based upon loading conditions obtained from the gait analysis of an amputee and validated experimentally using mechanical testing. The model was then used to address effects of viscoelastic heel performance numerically. This is just one example of the type of parametric analysis and design enabled by this approach. More importantly, by incorporating the unique gait characteristics of the amputee, these parametric analyses may lead to prosthetic feet more appropriately representing a particular user's needs, comfort and activity level.  相似文献   

3.
This paper reports on a methodology developed for studying the effects of various types of prosthetic feet on the gait of trans-femoral amputees. It is shown that an analysis in three planes of motion of not only the prosthetic, but also the sound limb provides important information on the performance of prosthetic feet. Two male trans-femoral amputees were tested with four different prosthetic feet; the Springlite II, Carbon Copy III, Seattle LightFoot and the Multiflex foot. A detailed analysis of the results of one amputee and a summary of the most important results of a second subject is presented. The tests were carried out at normal (1.16 m s(-1)) and fast (1.56 m s(-1)) walking speeds. Three dimensional gait analysis was carried out to derive the time curves of the joint angles, intersegmental moments and power at the ankle, knee and hip joints at both the prosthetic and sound sides. A higher first peak of the ground reaction force at the sound side with the Seattle LightFoot compared to that with the Springlite II, may be the result of the lower late stance dorsiflexion angle with the former. Compared to the other two feet, the Carbon Copy III and the Springlite II showed higher prosthetic dorsiflexing moments and positive power at late stance, which could assist in the push-off. The 3D intersegmental loads at the ankle and knee can be used as a guide for design and for compilation of standards for testing of lower limb prostheses incorporating flexible feet.  相似文献   

4.
Stance phase joint moments, muscle power outputs and mechanical energy characteristics were determined in five normal and five below knee amputee subjects running at 2.8 m s-1. The amputees were studied sequentially on three different prosthetic feet: the SACH foot (solid ankle cushion heel), and two energy storing feet, Seattle and Flex. While wearing the SACH foot, the amputees exhibited major alterations in the distribution and magnitude of muscle power output and muscle work: (1) the total work done by the lower extremity was reduced; (2) the hip extensors became the main source of energy absorption and generation, while in normal subjects the ankle plantarflexors were the major energy generators and the knee extensors the major energy absorbers; (3) the eccentric and concentric knee extensor power outputs were reduced and an abnormal concentric knee flexor power output was noted immediately after heel contact. In four of the amputees, energy storing feet resulted in improvements in the power output and mechanical work characteristics of the lower extremity: (1) the energy storing prosthetic feet generated 2-3 times greater energy than the SACH foot; (2) with the Flex foot the amputees exhibited a more normal pattern and magnitude of hip and knee extensor muscle work. One of the subjects, however, exhibited increased abnormalities with the energy storing prosthetic feet. The amount of energy restored relative to the amount of energy absorbed by each of the prosthetic feet was greater with the energy storing feet than the SACH foot (Flex 84%, Seattle 52%, SACH 31%).  相似文献   

5.
The mobility of above-knee amputees (A/K) is limited, in part, due to the performance of A/K prostheses during the stance phase. Currently stance phase control of most conventional A/K prostheses can only be achieved through leg alignment and choice of the SACH (Solid Ankle Cushioned Heel) foot. This paper examines the role of the knee controller in relation to a SACH foot during the stance phase of level walking. The three-dimensional gait mechanics were measured under two stance phase conditions. In the first set of trials, the amputee used a prosthesis with a conventional knee controller that allowed the amputee to maintain the knee joint in full extension during the stance phase. In the second set of trials, the prosthetic knee, during stance, echoed the modified kinematics of the amputee's sound (intact) knee that had been recorded during the previous sound stance phase. Analysis and interpretation of the data indicate the following: (1) SACH foot design can strongly influence the walking mechanics independent of the knee controller; (2) knee controller design and SACH foot design are mutually interdependent; and (3) normal kinematics imposed on the prosthetic knee does not necessarily produce normal hip kinematics (e.g. reduce the abnormal rise in the prosthetic side hip trajectory). Future research is necessary to explore and exploit the interdependency of prosthetic knee control and foot design.  相似文献   

6.
Despite walking with a wider step width, amputees remain 20% more likely to fall than non-amputees. Since mediolateral (ML) balance is critical for ambulation and contingent on ML foot placement, we used a ML disturbance to perturb walking balance and explore the influence of prosthetic foot stiffness on balance recovery. Ten transtibial amputees were fit with two commonly prescribed prosthetic feet with differing stiffness characteristics; 12 non-amputees also participated. A perturbation device that released an air burst just before heel strike imposed a repeatable medial or lateral disturbance in foot placement. After a medial disturbance, the first recovery step width was narrowed (p<0.0001) for the prosthetic limb (−103%), the sound limb (−51%) and non-amputees (−41%) and more than twice as variable. The ML inclination angle remained reduced (−109%) for the prosthetic limb, while the sound limb and non-amputees approached undisturbed levels (p<0.0004). Amputees required five steps to return to undisturbed step width after a prosthetic medial disturbance versus two steps for the sound limb and for non-amputees. After a lateral disturbance, the first recovery step was widened for the prosthetic limb (+82%), sound limb (+75%), and wider than non-amputees (+51%; p<0.0001), with all participants requiring three steps to return to undisturbed step width. Amputees also exhibited a similar upper torso response compared to the non-amputees for both disturbances. Prosthetic feet with different stiffness properties did not have a significant effect. In conclusion, amputee balance was particularly challenged by medial disturbances to the prosthetic limb implying a need for improved interventions that address these balance deficits.  相似文献   

7.
The influence of limb alignment on the gait of above-knee amputees.   总被引:2,自引:0,他引:2  
Biomechanical gait tests on above-knee amputees were conducted in which the alignment of the prosthesis was changed systematically. An eight-segment biomechanical model of the above-knee amputee was developed to analyse and present the three-dimensional kinematic and kinetic data obtained. The effects of alignment changes on the above-knee amputees' gait were studied in terms of the angular displacements of the lower limbs, ground reactions and intersegmental moments. It was found that following the alignment changes the angular displacement at the hip joint on the prosthetic side showed compensatory actions by the amputee. The ground reaction force was sensitive to alignment changes, and in particular, the changes in the characteristics of the fore-aft component of the ground force could be related to the alignment changes. The antero-posterior intersegmental moments at the prosthetic ankle and knee joints were evidently influenced by alignment.  相似文献   

8.
Lower limb amputees have decreased balance during daily ambulation compared to nonamputees. An optimally compliant torsion adapter, which enables transverse plane rotation at the socket–pylon junction may reduce limb asymmetries and improve comfort leading to increased confidence and stability during gait. The purpose of this study was to determine if the presence of a torsion adapter affects amputee sensitivity to local perturbations (local dynamic stability) during straight-line walking and during a turning task. Ten unilateral transtibial amputees were fit with a torsion and rigid adapter in random order and blinded to the condition. After a 3-week acclimation period, kinematic data were collected while subjects walked in a straight-line on a treadmill and around a 1-m radius circular path at constant speed. Maximum finite-time Lyapunov exponents (λ), an estimator of local dynamic stability, were calculated for the amputee’s sagittal plane hip, knee and ankle angles for each condition. The prosthetic limb λ was greater during a turn compared to straight-line walking, suggesting amputees are less stable while turning. There were no statistically significant differences found in λ between adapters during both walking conditions, suggesting the torsion adapter had no effect on amputee stability; however, high inter-subject variability due to the examined population and turning task may have masked a small decrease in prosthetic limb hip and knee stability for the torsion adapter during straight-line gait. Therefore, the torsion adapter’s added degree of freedom may have a small adverse effect on prosthetic limb stability during straight-line walking and no effect on turning.  相似文献   

9.
Recent studies have determined a seemingly consistent feature of able-bodied level ground walking, termed the roll-over shape, which is the effective rocker (cam) shape that the lower limb system conforms to between heel contact and contralateral heel contact during walking (first half of the gait cycle). The roll-over shape has been found to be largely unaffected by changes in walking speed, load carriage, and shoe heel height. However, it is unclear from previous studies whether persons are controlling their lower limb systems to maintain a consistent roll-over shape or whether this finding is a byproduct of their attempt to keep ankle kinematic patterns similar during the first half of the gait cycle. We measured the ankle–foot roll-over shapes and ankle kinematics of eleven able-bodied subjects while walking on rocker shoes of different radii. We hypothesized that the ankle flexion patterns during single support would change to maintain a similar roll-over shape. We also hypothesized that with decrease in rocker shoe radii, the difference in ankle flexion between the end and beginning of single support would decrease. Our results supported these hypotheses. Ankle kinematics were changed significantly during walking with the different rocker shoe radii (p<0.001), while ankle–foot roll-over shape radii (p=0.146) and fore–aft position (p=0.132) were not significantly affected. The results of this study have direct implications for designers of ankle–foot prostheses, orthoses, walking casts/boots, and rocker shoes. The results may also be relevant to researchers studying control of human movements.  相似文献   

10.
In human gait analysis studies, the entire foot is typically modeled as a single rigid-body segment; however, this neglects power generated/absorbed within the foot. Here we show how treating the entire foot as a rigid body can lead to misunderstandings related to (biological and prosthetic) foot function, and distort our understanding of ankle and muscle-tendon dynamics. We overview various (unconventional) inverse dynamics methods for estimating foot power, partitioning ankle vs. foot contributions, and computing combined anklefoot power. We present two case study examples. The first exemplifies how modeling the foot as a single rigid-body segment causes us to overestimate (and overvalue) muscle-tendon power generated about the biological ankle (in this study by up to 77%), and to misestimate (and misinform on) foot contributions; corroborating findings from previous multi-segment foot modeling studies. The second case study involved an individual with transtibial amputation walking on 8 different prosthetic feet. The results exemplify how assuming a rigid foot can skew comparisons between biological and prosthetic limbs, and lead to incorrect conclusions when comparing different prostheses/interventions. Based on analytical derivations, empirical findings and prior literature we recommend against computing conventional ankle power (between shank-foot). Instead, we recommend using an alternative estimate of power generated about the ankle joint complex (between shank-calcaneus) in conjunction with an estimate of foot power (between calcaneus-ground); or using a combined anklefoot power calculation. We conclude that treating the entire foot as a rigid-body segment is often inappropriate and ill-advised. Including foot power in biomechanical gait analysis is necessary to enhance scientific conclusions, clinical evaluations and technology development.  相似文献   

11.
12.
13.
14.
Dynamic elastic response prosthetic feet generally utilize a solid ankle, limiting dominant motion to the sagittal plane. However, researchers often use total rotational ankle joint power in the analysis of these feet. This investigation measured joint power terms in each plane for the Carbon Copy High Performance prosthetic foot. The significance of the frontal and transverse plane terms was assessed. Addition of these terms to the dominant sagittal power term revealed only slight differences, indicating that the sagittal power term is likely sufficient.  相似文献   

15.
Non-articulated energy storage and return prosthetic feet lack any true articulation or obvious point of rotation. This makes it difficult to select a joint center about which to estimate their kinetics. Despite this absence of any clear point of rotation, methods for estimating the kinetic performance of this class of prosthetic feet typically assume that they possess a fixed center of rotation and that its location is well approximated by the position of the contralateral lateral malleolus. To evaluate the validity of this assumption we used a finite helical axis approach to determine the position of the center of rotation in the sagittal plane for a series of non-articulated energy storage and return prosthetic feet. We found that over the course of stance phase, the sagittal finite helical axis position diverged markedly from the typically assumed fixed axis location. These results suggest that researchers may need to review center of rotation assumptions when assessing prosthetic foot kinetics, while clinicians may need to reconsider the criteria by which they prescribe these prosthetic feet.  相似文献   

16.
The duration of stance and swing phase and step and stride length are important parameters in human gait. In this technical note a low-cost ultrasonic motion analysis system is described that is capable of measuring these temporal and spatial parameters while subjects walk on the floor. By using the propagation delay of sound when transmitted in air, this system is able to record the position of the subjects' feet. A small ultrasonic receiver is attached to both shoes of the subject while a transmitter is placed stationary on the floor. Four healthy subjects were used to test the device. Subtracting positions of the foot with zero velocity yielded step and stride length. The duration of stance and swing phase was calculated from heel-strike and toe-off. Comparison with data obtained from foot contact switches showed that applying two relative thresholds to the speed graph of the foot could reliably generate heel-strike and toe-off. Although the device is tested on healthy subjects in this study, it promises to be extremely valuable in examining pathological gait. When gait is asymmetrical, walking speed is not constant or when patients do not completely lift their feet, most existing devices will fail to correctly assess the proper gait parameters. Our device does not have this shortcoming and it will accurately demonstrate asymmetries and variations in the patient's gait. As an example, the recording of a left hemiplegic patient is presented in the discussion.  相似文献   

17.
Improvements in surgical techniques and prosthetic devices and the establishment of prosthetic clinics have altered the outlook for the amputee. A cooperative effect on the part of professionals looking after amputee patients, as carried out in these clinics, offers the best means of recognition and treatment of difficulties as they arise. Until the "bionic man" becomes a reality, amputees will continue to have skin problems. In describing a number of illustrative cases, we have attempted to: (a) renew interest in these problems; (b) demonstrate the value of the group approach; and (c) encourage the participation of interested dermatologists in the prosthetic clinic team to facilitate earlier recognition and treatment of troublesome skin disorders in the amputee.  相似文献   

18.
The presence of multiple foot types has been used to explain the variability of foot structure observed among healthy adults. These foot types were determined by specific static morphologic features and included rectus (well aligned hindfoot/forefoot), planus (low arched), and cavus (high arched) foot types. Unique biomechanical characteristics of these foot types have been identified but reported differences in segmental foot kinematics among them has been inconsistent due to differences in neutral referencing and evaluation of only select discrete variables. This study used the radiographically-indexed Milwaukee Foot Model to evaluate differences in segmental foot kinematics among healthy adults with rectus, planus, and cavus feet based on the true bony alignment between segments. Based on the definitions of the individual foot types and due to conflicting results in previous literature, the primary study outcome was peak coronal hindfoot position during stance phase. Additionally, locally weighted regression smoothing with alpha-adjusted serial t-test analysis (LAAST) was used to compare these foot types across the entire gait cycle. Average peak hindfoot inversion was −1.6° ± 5.1°, 6.7° ± 3.5°, and 13.6° ± 4.6°, for the Planus, Rectus, and Cavus Groups, respectively. There were significant differences among all comparisons. Differences were observed between the Rectus and Planus Groups and Cavus and Planus Groups throughout the gait cycle. Additionally, the Planus Group had a premature peak velocity toward coronal varus and early transition toward valgus, likely due to a deficient windlass mechanism. This assessment of kinematic data across the gait cycle can help understand differences in dynamic foot function among foot types.  相似文献   

19.
Legged robots relying on dry adhesives for vertical climbing are required to preload their feet against the wall to increase contact surface area and consequently maximize adhesion force. Preloading a foot causes a redistribution of forces in the entire robot, including contact forces between the other feet and the wall. An inappropriate redistribution of these forces can cause irreparable detachment of the robot from the vertical surface. This paper investigates an optimal preloading and detaching strategy that minimizes energy consumption, while retaining safety, during locomotion on vertical surfaces. The gait of a six-legged robot is planned using a quasi-static model that takes into account both the structure of the robot and the characteristics of the adhesive material. The latter was modelled from experimental data collected for this paper. A constrained optimization routine is used, and its output is a sequence of optimal posture and motor torque set-points.  相似文献   

20.
A principle objective of human walking is controlling angular motion of the body as a whole to remain upright. The force of the ground on each foot (F) reflects that control, and recent studies show that in the sagittal plane F exhibits a specific coordination between F direction and center-of-pressure (CP) that is conducive to remaining upright. Typical walking involves the CP shifting relative to the body due to two factors: posterior motion of the foot with respect to the hip (stepping) and motion of the CP relative to the foot (foot roll-over). Recent research has also shown how adjusting ankle torque alone to shift CP relative to the foot systematically alters the direction of F, and thus, could play a key role in upright posture and the F measured during walking. This study explores how the CP shifts due to stepping and foot roll-over contribute to the observed F and its role in maintaining upright posture. Experimental walking kinetics and kinematics were combined with a mechanical model of the human to show that variation in F that was not attributable to foot roll-over had systematic correlation between direction and CP that could be described by an intersection point located near the center-of-mass. The findings characterize a component of walking motor control, describe how typical foot roll-over contributes to postural control, and provide a rationale for the increased fall risk observed in individuals with atypical ankle muscle function.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号