首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Diagnosing dysfunctional atlantoaxial motion is challenging given limitations of current diagnostic imaging techniques. Three-dimensional imaging during upright functional motion may be useful in identifying dynamic instability not apparent on static imaging. Abnormal atlantoaxial motion has been linked to numerous pathologies including whiplash, cervicogenic headaches, C2 fractures, and rheumatoid arthritis. However, normal C1/C2 rotational kinematics under dynamic physiologic loading have not been previously reported owing to imaging difficulties. The objective of this study was to determine dynamic three-dimensional in vivo C1/C2 kinematics during upright axial rotation. Twenty young healthy adults performed full head rotation while seated within a biplane X-ray system while radiographs were collected at 30 images per second. Six degree-of-freedom kinematics were determined for C1 and C2 via a validated volumetric model-based tracking process. The maximum global head rotation (to one side) was 73.6 ± 8.3°, whereas maximum C1 rotation relative to C2 was 36.8 ± 6.7°. The relationship between C1/C2 rotation and head rotation was linear through midrange motion (±20° head rotation from neutral) in a nearly 1:1 ratio. Coupled rotation between C1 and C2 included 4.5 ± 3.1° of flexion and 6.4 ± 8.2° of extension, and 9.8 ± 3.8° of contralateral bending. Translational motion of C1 relative to C2 was 7.8 ± 1.5 mm ipsilaterally, 2.2 ± 1.2 mm inferiorly, and 3.3 ± 1.0 mm posteriorly. We believe this is the first study describing 3D dynamic atlantoaxial kinematics under true physiologic conditions in healthy subjects. C1/C2 rotation accounts for approximately half of total head axial rotation. Additionally, C1 undergoes coupled flexion/extension and contralateral bending, in addition to inferior, lateral and posterior translation.  相似文献   

2.
AimThe aim of the study was to evaluate computed tomography (CT) artifacts and image recognition of the CyberKnife system. Regarding fiducial markers, VISICOIL of 0.5 mm × 5.0 mm and 0.75 mm × 5.0 mm, ball-shaped Gold Anchor (GA) of 0.28 mm × 10 mm and 0.28 mm × 20 mm, were compared with the standard cylinder marker of 0.9 mm × 3.0 mm (ACCULOC).BackgroundRecently, various kinds of commercial fiducial markers have been available in CyberKnife treatment.Materials and methodsThe CT images of a water equivalent gel with each fiducial marker were acquired for the evaluation of CT artifacts. The evaluation was performed using the standard deviation of Hounsfield Unit (HU) value for a rectangle region near the fiducial marker. Then, to evaluate the image recognition, each fiducial marker was located to overlap in the target locating system (TLS) for the two sites; the vertebral bone and the pubic bone.ResultsFor CT artifacts, the standard deviations of the VISICOIL of 0.5 mm × 5.0 mm was the smallest. The image recognition of four fiducial markers had a value close to the standard cylinder marker and was feasible for common use, but was slightly poorer when using GA of 0.28 mm × 10 mm in the dynamic conditions.ConclusionOur results indicated that VISICOIL 0.5 × 5.0 mm and the GAs can be used nearly always for CyberKnife treatment in spite of their much thinner needles than those of cylinder types.  相似文献   

3.
The purpose of this study was to determine the changes that occur in tendinous tissue properties during the early phase of tetanic summation in the in vivo human tibialis anterior muscle (TA). The torque response and tendinous tissue elongation following single stimuli, two-pulse trains, and three-pulse trains were recorded in the TA during isometric contractions. The elongation, compliance, and lengthening velocity of tendinous tissue were determined by real-time ultrasonography. The contribution of the response to the second stimulation (C2) was obtained by subtracting the response to the single stimulation (C1) from the response of doublet. The third contribution (C3) was obtained by subtracting the response to the doublet from that of the triplet. C2 (7.8±0.5 Nm) and C3 (7.3±0.6 Nm) had torque responses significantly higher than C1 (3.6±0.7 Nm). In contrast, the elongations of tendinous tissue for C2 (2.8±0.4 mm) and C3 (1.7±0.2 mm) were significantly lower than for C1 (4.9±0.3 mm), indicating that the summation pattern of tendinous tissue elongation is different from the summation pattern of torque response. In addition, this showed considerable difference both between C1 (0.12±0.01 mm/N; 83±4.6 mm/s) and C2 (0.03±0.005 mm/N; 50±6.3 mm/s) and between C1 and C3 (0.02±0.002 mm/N; 39±6.4 mm/s) in the compliance and lengthening velocity of tendinous tissue. These results suggest that changes in tendinous tissue properties between first and second contraction are related to different summation patterns of force and tendinous tissue elongation during early phase of tetanic summation.  相似文献   

4.
PurposeTo evaluate the respiratory motion of adrenal gland metastases in three-dimensional directions using four-dimensional computed tomography (4DCT) images.MethodsFrom January 2013 to May 2016, 12 patients with adrenal gland metastases were included in this study. They all underwent 4DCT scans to assess respiratory motion of adrenal gland metastases in free breathing state. The 4DCT images were sorted into 10 image series according to the respiratory phase from the end inspiration to the end expiration, and then transferred to FocalSim workstation. All gross tumor volumes (GTVs) of adrenal gland metastases were drawn by a single physician and confirmed by a second. Relative coordinates of adrenal gland metastases were automatically generated to calculate adrenal gland metastases motion in different axial directions.ResultsThe average respiratory motion of adrenal gland metastases in left-right (LR), cranial-caudal (CC), anterior-posterior (AP), 3-dimensional (3D) vector directions was 3.4 ± 2.2 mm, 9.5 ± 5.5 mm, 3.8 ± 2.0 mm and 11.3 ± 5.3 mm, respectively. The ratios were 58.6% ± 11.4% and 63.2% ± 12.5% when the volumes of GTVIn0% and GTV In100% were compared with volume of IGTV10phase. The volume ratio of IGTV10phase to GTV3D was 1.73 ± 0.48.ConclusionsAdrenal gland metastasis is a respiration-induced moving target, and an internal target volume boundary should be provided when designing the treatment plan. The CC motion of adrenal gland metastasis is predominant and >5 mm, thus motion management strategies are recommended for patients undergoing external radiotherapy for adrenal gland metastasis.  相似文献   

5.
Accurate measurement of cartilage deformation in loaded cadaver hip joints could be a valuable tool to answer clinically relevant research questions. MRI is a promising tool, but its use requires an understanding of cartilage deformation and recovery properties in the intact hip. Our objective was to answer the following questions: (1) How long does it take for hip cartilage to reach a deformed steady-state thickness distribution under simulated physiological load, and how much does the cartilage deform? (2) How long does it take for hip cartilage to return to the original cartilage thickness distribution once the load is removed?MethodsFive human hip specimens were axially loaded to 1980 N in a 7 T MR scanner and scanned every 15 min throughout loading. One specimen was scanned every hour throughout recovery from load. One repeatability specimen was loaded and scanned every day for 4 days. Hip cartilage was segmented as a single unit and thickness was measured radially.ResultsThe hip cartilage reached a steady-state thickness distribution after 225 min of load, and 16.5 h of recovery. Mean strain after 225 min of load was 30.9%. The repeatability specimen showed an average day-to-day change in mean cartilage thickness of 0.10 mm over 4 days of data collection. The amount of deformation (0.96 mm) was far greater than the image resolution (0.11 mm) and error due to repeatability (0.10 mm).ConclusionUsing an ex vivo model, this method has potential for assessing changes in hip cartilage strain due to injury or surgical intervention.  相似文献   

6.
Changes in extracellular matrix (ECM) are one of many components that contribute to impaired wound healing in aging. This study examined the effect of age on the glycosaminoglycan hyaluronan (HA) in normal and wounded dermis from young (4–6 month-old) and aged (22–24 month-old) mice. HA content and size were similar in the normal dermis of young and aged mice. Dermal explants labeled with [3H]-glucosamine showed decreased generation of smaller forms of HA in aged explants relative to young explants. Aged mice exhibited delayed wound repair compared with young mice with the greatest differential at 5 days. Expression of hyaluronan synthase (HAS) 2 and 3, and hyaluronidase (HYAL) 1–3 mRNA in wounds of young and aged mice was similar. There was a trend toward a decreased HYAL protein expression in aged wound dermis, which was accompanied by changes in detectable HYAL activity. Total HA content was similar in young and aged wound dermis. There was significantly less HA in the lower MW range (~ 250 kDa and smaller) in 5-day wound dermis, but not in 9-day wound dermis, from aged mice relative to young mice. We propose that decreased cleavage of HA is an additional component of impaired dermal wound healing in aging.  相似文献   

7.
8.
PurposeTo measure phrenic nerve conduction velocity in the neck in humans.ScopeWe studied 15 healthy subjects (9 men, 32.4 ± 6.7). We performed bipolar electrical phrenic stimulation in the neck, from a distal and a proximal stimulation site, and recorded diaphragm electromyographic responses on the surface of the chest. The ratio of the between-site distance to the latency difference provided phrenic velocities. Ulnar motor velocity was assessed similarly. In addition, five homogeneous patients with Charcot-Marie-Tooth disease type 1A (CMT1A) were studied for validation purposes. We obtained diaphragmatic responses from the two stimulation sites in all cases. The distal latencies (anterior axillary line recording) were 6.51 ± 0.63 ms (right) and 6.13 ± 0.64 ms (left). The minimal between site distance was 39 mm. Phrenic motor velocity was 55.2 ± 6.3 m s?1 (right) and 56.3 ± 7.2 m s?1 (left). In CMT1A, phrenic velocities were 17.1 ± 8.1 m s?1 (from 7 to 32 m s?1) and were similar to ulnar and median velocities.ConclusionsPhrenic nerve velocities can be estimated in humans and compare with upper limb motor conduction velocities. This should refine the investigation of phrenic function in peripheral neuropathies.  相似文献   

9.
《Small Ruminant Research》2009,82(2-3):90-95
The aim of this study was to determine the effects of the antioxidants glutamine and hyaluronan and the inclusion of different levels on microscopic semen parameters, lipid peroxidation and the antioxidant activities following the freeze–thawing of Angora goat semen. Ejaculates collected from three Angora goat bucks, were evaluated and pooled at 37 °C. The semen samples which were diluted with a Tris-based extender containing additives including glutamine (2.5; 5 mM) and hyaluronan (500; 1000 μl/ml), and an extender containing no antioxidants (control) were cooled to 5 °C and frozen in 0.25 ml French straws and stored in liquid nitrogen. Frozen straws were thawed individually (37 °C) for 20 s in a water bath for microscopic evaluation. Freezing extenders supplemented with 2.5 and 5 mM glutamine led to higher sperm motility and hypo-osmotic swelling test (HOST) values, compared to the control (P < 0.05) following the freeze–thawing process. The addition of 500 μl/ml hyaluronan resulted in a higher HOST percentage, compared to the addition of 1000 μl/ml hyaluronan and the control (P < 0.001). No significant difference was recorded in the percentage acrosome and total sperm abnormalities, following supplementation with antioxidants. The addition of antioxidants did not prevent malondialdehyde (MDA) formation, compared to the controls. Antioxidant treatment however decreased (P < 0.01) the superoxide dismutase (SOD) activity. The maintenance of catalase (CAT) activity was demonstrated to be insignificant following addition of antioxidants. Further studies are required to obtain more repeatable results regarding the characterization of the enzymatic and non-enzymatic antioxidant systems in cryopreserved goat sperm.  相似文献   

10.
The Pacinian corpuscle (PC) is a cutaneous mechanoreceptor sensitive to high-frequency vibrations (20–1000 Hz). The PC is of importance due to its integral role in somatosensation and the critical need to understand PC function for haptic feedback system development. Previous theoretical and computational studies have modeled the physiological response of the PC to sustained or vibrating mechanical stimuli, but they have used estimates of the receptor’s mechanical properties, which remain largely unmeasured. In this study, we used micropipette aspiration (MPA) to determine an apparent Young’s modulus for PCs isolated from a cadaveric human hand. MPA was applied in increments of 5 mm H2O (49 Pa), and the change in protrusion length of the PC into the pipette was recorded. The protrusion length vs. suction pressure data were used to calculate the apparent Young’s modulus. Using 10 PCs with long-axis lengths of 2.99 ± 0.41 mm and short-axis lengths of 1.45 ± 0.22 mm, we calculated a Young’s modulus of 1.40 ± 0.86 kPa. Our measurement is on the same order of magnitude as those approximated in previous models, which estimated the PC to be on the same order of magnitude as skin or isolated cells, so we recommend that a modulus in the kPa range be used in future studies.  相似文献   

11.
The objectives of this study was to investigate the acute effects of various magnitudes of tendon strain on the mechanical properties of the human medial gastrocnemius (MG) in vivo during controlled heel-drop exercises. Seven male and seven female volunteers performed two different exercises executed one month apart: one was a heel-drop exercise on a block (HDB), and the other was a heel-drop exercise on level floor (HDL). In each regimen, the subjects completed a session of 150 heel-drop exercises (15 repetitions × 10 sets; with a 30 s rest following each set). Before and immediately after the heel-drop exercise, the ankle plantar flexor torque and elongation of the MG were measured using a combined measurement system of dynamometry and ultrasonography and then the MG tendon strain and stiffness were evaluated in each subject. The tendon stiffness measured prior to the exercises was not significantly different between the two groups 23.7 ± 10.6 N/mm and 24.1 ± 10.0 N/mm for the HDB and HDL, respectively (p > .05). During the heel-drop exercise, it was found that the tendon strain during the heel-drop exercise on a block (8.4 ± 3.7%) was significantly higher than the strain measured on the level floor (5.4 ± 3.8%) (p < .05). In addition, the tendon stiffness following the heel-drop exercise on a block (32.3 ± 12.2 N/mm) was significantly greater than the tendon stiffness measured following the heel-drop exercise on the level floor (25.4 ± 11.4 N/mm) (p < .05). The results of this study suggest that tendon stiffness immediately following a heel-drop exercise depends on the magnitude of tendon strain.  相似文献   

12.
Aerobic granular sludge was cultivated in a glass sequencing batch reactor (SBR) with glucose synthetic wastewater. The spherical shaped granules were observed on 4th day with the mean diameter of 0.1 mm. With the increase of chemical oxygen demand (COD) concentration of the influent, aerobic granules grew matured, the size of which ranged from 1.2 to 1.9 mm. The aerobic granular sludge could sustain high organic loading rate (about 4.0 g COD L−1 d−1), with good settling ability (settling velocity 36 m/h) and high biomass concentration (MLSS 6.7 ±0.2 g/L). Experimental data indicated that the substrate utilization and biomass growth kinetics followed Monod's kinetics model approximately. The corresponding kinetic coefficients of maximum specific substrate utilization rate (k), half velocity coefficient (Ks), growth yield coefficient (Y) and decay coefficient (Kd) were 13.2 d−1, 275.8 mg/L, 0.183–0.250 mg MLSS/mg COD and 0.023–0.075 d−1, respectively, which made aerobic granules have short setup period, high rate of substrate utilization and little surplus sludge.  相似文献   

13.
Optical motion capture is commonly used in biomechanics to measure human kinematics. However, no studies have yet examined the accuracy of optical motion capture in a large capture volume (>100 m3), or how accuracy varies from the center to the extreme edges of the capture volume. This study measured the dynamic 3D errors of an optical motion capture system composed of 42 OptiTrack Prime 41 cameras (capture volume of 135 m3) by comparing the motion of a single marker to the motion reported by a ThorLabs linear motion stage. After spline interpolating the data, it was found that 97% of the capture area had error below 200 μm. When the same analysis was performed using only half (21) of the cameras, 91% of the capture area was below 200 μm of error. The only locations that exceeded this threshold were at the extreme edges of the capture area, and no location had a mean error exceeding 1 mm. When measuring human kinematics with skin-mounted markers, uncertainty of marker placement relative to underlying skeletal features and soft tissue artifact produce errors that are orders of magnitude larger than the errors attributed to the camera system itself. Therefore, the accuracy of this OptiTrack optical motion capture system was found to be more than sufficient for measuring full-body human kinematics with skin-mounted markers in a large capture volume (>100 m3).  相似文献   

14.
The purpose of this study was to investigate the effect of image quality under various imaging parameters (60, 70, 80, 90, 100, 110, and 120 kV at 200 mA and 10 ms/63, 80, 100, 160, 200, 250, and 320 mA at 120 kV and 10 ms) and the diameter of the fiducial marker (0.25, 0.50, 0.75, and 1.10 mm) on the correlation modeling error for dynamic tumor tracking (DTT) in the Vero4DRT system. Each fiducial marker was inserted into the center of the 30 × 30 × 10 cm3 water-equivalent phantom. A programmable respiratory motion table was used to simulate breathing-induced organ motion, with an amplitude of ±20 mm and a breathing cycle of 4 s. The correlation modeling error was calculated from the absolute difference between the detected and predicted target positions in the cranio-caudal direction. The image contrast of the fiducial marker was enhanced with increasing kV and mA. Increasing the diameter of the fiducial marker also enhanced the image contrast. Correlation-modeling error does not depend on the image quality and fiducial marker diameter. A lower kV setting did not generate a 4D model due to poor image contrast. All fiducial marker diameters were identified as good candidates for DTT in the Vero4DRT system.  相似文献   

15.
Warneckea populations from “sand-forest” or “sand-thicket” habitats in Tembe Elephant Park, South Africa, and Licuati Forest Reserve in adjacent southern Mozambique were previously thought to be a small-leaved form of W. sousae, which typically includes larger-leaved plants ranging from central Mozambique northward to Tanzania. We examine this hypothesis using molecular and morphological evidence. Maximum-likelihood phylogenetic analysis of combined nrDNA ETS and ITS sequence data failed to resolve W. sousae and the Maputaland populations as an exclusively monophyletic group. Instead, the Kenyan endemic W. mouririifolia was strongly supported as the sister species of W. sousae, and the Maputaland plants were resolved in a separate, strongly supported clade together with populations of an as-yet undetermined Warneckea species from northern Mozambique. A hypothesis of exclusive monophyly for the plants from Tembe and Licuati had moderate support in separate ETS and ITS1 analyses (bootstrap proportions of 88% and 81%, respectively). Statistically significant differences in leaf dimensions and internode length were found between the Maputaland plants and typical W. sousae. We conclude that the populations from Tembe and Licuati represent a distinct species, which we describe as W. parvifolia. The species differs from W. sousae in having shorter internodes (mostly 5–25 mm not 10–60 mm long), smaller leaves (mostly 14–32 × 8–19 mm not 40–76 × 22–52 mm), shorter petioles (mostly 1–1.5 mm not 1.5–6 mm long), smaller flowers (hypanthium 1 × 1.5–1.75 mm not 1.5–2 × 2 mm; calyx lobes 0.5 mm not 0.75 mm long; staminal filaments 3–4 mm not 5 mm long; style 4–5 mm not 9 mm long), and globose fruit (not obovoid). An IUCN conservation status of Endangered (EN) B1a, b(ii, iii) is indicated for W. parvifolia, due to its limited distribution and projected declines in its habitat quality and area of occupancy.  相似文献   

16.
We characterized anoxic nitrate granules produced by an alternating current biofilm electrode reactor operating at low voltage-low frequency under optimum conditions. Hydrodynamic results revealed that the settling velocity for the granules ranged from 0.12 to 2.85 cm/s, while that of settling velocities ranged from 0.07 to 3.42 cm/s. Granule diameter varied, with a mean mass of 3.65 ± 1.29 mm and corresponding dry mass ranging from 0.52 to 5.64 mg. Roundness ratio of the sampled granules was determined to be 0.78 ± 0.11. Integrity coefficient obtained from a shear strength test was 87.05 ± 2.07% after 2 min and 74.1 ± 4.14% after 5 min. An adhesion test revealed hydrophilic properties of bacteria. The Most probable number (MPN) value was 2.0 × 106 for HDB and 2.0 × 103 for ADB. An apoptosis assay by flow cytometry confirmed that the majority of cells (87.7%) were viable and non-apoptotic (Annexin V-PI) and dehydrogenase activity was 15.05 ± 1.76 μg TF/mg biomass cm−2 d. Comparison of seed and granules by 1H NMR spectra showed different signals in the range of 0.279–1, 1–1.5, and 1.5–7.5 ppm. Therefore, the biofilm in ACBER can be easily granulated and used to generate dense and fast-settling sludge granules.  相似文献   

17.
This study aimed to determine the characteristics of the in vivo behaviour of human muscle architecture during a pre-motion silent period (PMSP) using ultrasonography. Subjects were requested to perform rapid knee extension with vertical jumping. Electromyographic signals were recorded from the vastus lateralis (VL), vastus medialis, and biceps femoris muscles. Ultrasonic images were recorded from the VL. We found that the cross point between the fascicle and deep aponeurosis in the VL moved to the distal side before the rapid vertical jumps with PMSP. This cross point movement with PMSP was of low amplitude (mean: 1.0 ± 0.3 mm) and velocity (22.2 ± 6.1 mm/s). The amplitude and velocity of the cross point movement were significantly positively related to the angular peak velocity of knee extensor during rapid vertical jumping in trials with PMSP. These results suggest that although low levels of pre-movement muscle architectural change with PMSP may be the result of muscle relaxation behaviour rather than the result of muscle stretching behaviour, this pre-movement effect can influence subsequent muscular performance during a rapid voluntary movement. PMSP may allow pre-movement muscle architectural change to generate a better muscular condition to increase neural activation during the subsequent rapid voluntary contraction.  相似文献   

18.
The temporal lag between gene expression and metabolite accumulation has been estimated in flavonol biosynthesis, but the time difference between these events is unclear. In the present study, we investigated the expression of flavonol biosynthetic genes ELONGATED HYPOCOTYL5, MYELOBLASTOSIS PROYEIN12/PRODUCTION OF FLAVONOL GLYCOSYDES1, CHALCONE SYNTHASE, CHALCONE ISOMERASE, FLAVANONE 3-HYDROXYLASE, and FLAVONOL SYNTHASE1, and the accumulation of flavonol glycosides (kaempferol and quercetin glycosides) in time-series samples of Arabidopsis thaliana roots. All genes started to be expressed within 3 h after sequential light irradiation (HAS) and reached their maximum expression levels at 12 HAS, and the accumulation of the flavonol glycosides started at 6 HAS. Metabolome analysis using liquid chromatography-mass spectrometry showed that the accumulation of kaempferol 3-O-glucoside-7-O-rhamnoside and kaempferol 3-O-rhamnosyl (1  2) glucoside-7-O-rhamnoside reached their maximum levels at 48 HAS, whereas other flavonol glycosides, such as kaempferol/quercetin 3-O-rhamnoside-7-O-rhamnoside, quercetin 3-O-glucoside-7-O-rhamnoside and quercetin 3-O-rhamnosyl (1  2) glucoside-7-O-rhamnoside, increased gradually until 96 HAS. These results show that the expression of the flavonol genes is an early response against light exposure, and that the accumulation of the flavonol glycosides is a late response.  相似文献   

19.
The rising cost of musculoskeletal pathology, disease, and injury creates a pressing need for accurate and reliable methods to quantify 3D musculoskeletal motion, fostering a renewed interest in this area over the past few years. To date, cine-phase contrast (PC) MRI remains the only technique capable of non-invasively tracking in vivo 3D musculoskeletal motion during volitional activity, but current scan times are long on the 1.5T MR platform (~2.5 min or 75 movement cycles). With the clinical availability of higher field strength magnets (3.0T) that have increased signal-to-noise ratios, it is likely that scan times can be reduced while improving accuracy. Therefore, the purpose of this study is to validate cine-PC MRI on a 3.0T platform, in terms of accuracy, precision, and subject-repeatability, and to determine if scan time could be minimized. On the 3.0T platform it is possible to limit scan time to 2 min, with sub-millimeter accuracy (<0.33 mm/0.97°), excellent technique precision (<0.18°), and strong subject-repeatability (<0.73 mm/1.10°). This represents reduction in imaging time by 25% (42 s), a 50% improvement in accuracy, and a 72% improvement in technique precision over the original 1.5T platform. Scan time can be reduced to 1 min (30 movement cycles), but the improvements in accuracy are not as large.  相似文献   

20.
Shrimp head waste is a major byproduct of crustacean processing in North-eastern Brazil and represents an interesting source of bioactive molecules. Additionally, its use increases the sustainability of processing fishery products. The present study reports a process developed for recovering bioactive molecules from shrimp heads through autolysis. A protein hydrolysate (120 ± 0.4 g) formed by a 9% (w/v) solution was recovered and lyophilized from 1 kg of shrimp heads. Approximately 195 ± 0.5 mg of carotenoids was recovered as an ethanolic extract. The recovery of chitin and chitosan were 25 ± 2 g kg?1 and 17 ± 4 g kg?1 wet processing waste, respectively. Chitosans were characterized by 13C NMR, and FT-IR analysis and exhibited a variable degree of deacetylation (60–80%). Sulfated glycosaminoglycans that exhibited electrophoretic migration similar to mammalian standards were also recovered (79 ± 2 mg kg?1 wet processing waste), and their degradation products suggested the presence of C6-sulfated heparan sulfate. These data point to the feasibility of an integrated process for isolating highly bioactive molecules, such as sulfated- and amino-polysaccharides, with a broad spectrum of applications from shrimp processing waste.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号