首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A method for gait analysis using wearable acceleration sensors and gyro sensors is proposed in this work. The volunteers wore sensor units that included a tri-axis acceleration sensor and three single axis gyro sensors. The angular velocity data measured by the gyro sensors were used to estimate the translational acceleration in the gait analysis. The translational acceleration was then subtracted from the acceleration sensor measurements to obtain the gravitational acceleration, giving the orientation of the lower limb segments. Segment orientation along with body measurements were used to obtain the positions of hip, knee, and ankle joints to create stick figure models of the volunteers. This method can measure the three-dimensional positions of joint centers of the hip, knee, and ankle during movement. Experiments were carried out on the normal gait of three healthy volunteers. As a result, the flexion–extension (F–E) and the adduction–abduction (A–A) joint angles of the hips and the flexion–extension (F–E) joint angles of the knees were calculated and compared with a camera motion capture system. The correlation coefficients were above 0.88 for the hip F–E, higher than 0.72 for the hip A–A, better than 0.92 for the knee F–E. A moving stick figure model of each volunteer was created to visually confirm the walking posture. Further, the knee and ankle joint trajectories in the horizontal plane showed that the left and right legs were bilaterally symmetric.  相似文献   

2.
In this paper, an experimental analysis of overcoming obstacle in human walking is carried out by means of a motion capture system. In the experiment, the lower body of an adult human is divided into seven segments, and three markers are pasted to each segment with the aim to obtain moving trajectory and to calculate joint variation during walking. Moreover, kinematic data in terms of displacement, velocity and acceleration are acquired as well. In addition, ground reaction forces are measured using force sensors. Based on the experimental results, features of overcoming obstacle in human walking are ana- lyzed. Experimental results show that the reason which leads to smooth walking can be identified as that the human has slight movement in the vertical direction during walking; the reason that human locomotion uses gravity effectively can be identified as that feet rotate around the toe joints during toe-off phase aiming at using gravitational potential energy to provide propulsion for swing phase. Furthermore, both normal walking gait and obstacle overcoming gait are characterized in a form that can provide necessary knowledge and useful databases for the implementation of motion planning and gait planning towards overcoming obstacle for humanoid robots.  相似文献   

3.
When comparing previous studies that have measured the three-dimensional moments acting about the lower limb joints (either external moments or opposing internal joint moments) during able-bodied adult gait, significant variation is apparent in the profiles of the reported transverse plane moments. This variation cannot be explained on the basis of adopted convention (i.e. external versus internal joint moment) or inherent variability in gait strategies. The aim of the current study was to determine whether in fact the frame in which moments are expressed has a dominant effect upon transverse plane moments and thus provides a valid explanation for the observed inconsistency in the literature. Kinematic and ground reaction force data were acquired from nine able-bodied adult subjects walking at a self-selected speed. Three-dimensional hip, knee and ankle joint moments during gait were calculated using a standard inverse dynamics approach. In addition to calculating internal joint moments, the components of the external moment occurring in the transverse plane at each of the lower limb joints were calculated to determine their independent effects. All moments were expressed in both the laboratory frame (LF) as well as the anatomical frame (AF) of the distal segment. With the exception of the ankle rotation moment in the foot AF, lower limb transverse plane joint moments during gait were found to display characteristic profiles that were consistent across subjects. Furthermore, lower limb transverse plane joint moments during gait differed when expressed in the distal segment AF compared to the LF. At the hip, the two alternative reference frames produced near reciprocal joint moment profiles. The components of the external moment revealed that the external ground reaction force moment was primarily responsible for this result. Lower limb transverse plane joint moments during gait were therefore found to be highly sensitive to a change in reference frame. These findings indicate that the different transverse plane joint moment profiles during able-bodied adult gait reported in the literature are likely to be explained on this basis.  相似文献   

4.
The purpose of this paper was to describe a technique that enables three-dimensional (3D) gait kinematics to be obtained using an electromagnetic tracking system, and to report the intra-trial, intra-day/inter-tester and inter-day/intra-tester repeatability of kinematic gait data obtained using this technique. Ten able-bodied adults underwent four gait assessments; the same two testers tested each subject independently on two different days. Gait assessments were conducted on a custom-built long-bed treadmill with no metal components between the rollers. Each gait assessment involved familiarisation to treadmill walking, subject anatomical and functional calibration, and a period of steady-state treadmill walking at a self-selected speed. Following data collection, 3D joint kinematics were calculated using the joint coordinate system approach. 3D joint angle waveforms for 10 left and right strides were extracted and temporally normalised for each trial. Intra-trial, intra-day/inter-tester and inter-day/intra-tester repeatability of the temporally normalised kinematic waveforms were quantified using the coefficient of multiple determination (CMD). CMDs for joint kinematics averaged 0.942 intra-trial, 0.849 intra-day/inter-tester and 0.773 inter-day/intra-tester. In general, sagittal plane kinematics were more repeatable than frontal or transverse plane kinematics, and kinematics at the hip were more repeatable than at the knee or ankle. The level of repeatability of kinematic gait data obtained during treadmill walking using this protocol was equal or superior to that reported previously for overground walking using image-based protocols.  相似文献   

5.
A new method using a double-sensor difference based algorithm for analyzing human segment rotational angles in two directions for segmental orientation analysis in the three-dimensional (3D) space was presented. A wearable sensor system based only on triaxial accelerometers was developed to obtain the pitch and yaw angles of thigh segment with an accelerometer approximating translational acceleration of the hip joint and two accelerometers measuring the actual accelerations on the thigh. To evaluate the method, the system was first tested on a 2° of freedom mechanical arm assembled out of rigid segments and encoders. Then, to estimate the human segmental orientation, the wearable sensor system was tested on the thighs of eight volunteer subjects, who walked in a straight forward line in the work space of an optical motion analysis system at three self-selected speeds: slow, normal and fast. In the experiment, the subject was assumed to walk in a straight forward way with very little trunk sway, skin artifacts and no significant internal/external rotation of the leg. The root mean square (RMS) errors of the thigh segment orientation measurement were between 2.4° and 4.9° during normal gait that had a 45° flexion/extension range of motion. Measurement error was observed to increase with increasing walking speed probably because of the result of increased trunk sway, axial rotation and skin artifacts. The results show that, without integration and switching between different sensors, using only one kind of sensor, the wearable sensor system is suitable for ambulatory analysis of normal gait orientation of thigh and shank in two directions of the segment-fixed local coordinate system in 3D space. It can then be applied to assess spatio-temporal gait parameters and monitoring the gait function of patients in clinical settings.  相似文献   

6.
Robotic lower limb exoskeletons hold significant potential for gait assistance and rehabilitation; however, we have a limited understanding of how people adapt to walking with robotic devices. The purpose of this study was to test the hypothesis that people reduce net muscle moments about their joints when robotic assistance is provided. This reduction in muscle moment results in a total joint moment (muscle plus exoskeleton) that is the same as the moment without the robotic assistance despite potential differences in joint angles. To test this hypothesis, eight healthy subjects trained with the robotic hip exoskeleton while walking on a force-measuring treadmill. The exoskeleton provided hip flexion assistance from approximately 33% to 53% of the gait cycle. We calculated the root mean squared difference (RMSD) between the average of data from the last 15 min of the powered condition and the unpowered condition. After completing three 30-min training sessions, the hip exoskeleton provided 27% of the total peak hip flexion moment during gait. Despite this substantial contribution from the exoskeleton, subjects walked with a total hip moment pattern (muscle plus exoskeleton) that was almost identical and more similar to the unpowered condition than the hip angle pattern (hip moment RMSD 0.027, angle RMSD 0.134, p<0.001). The angle and moment RMSD were not different for the knee and ankle joints. These findings support the concept that people adopt walking patterns with similar joint moment patterns despite differences in hip joint angles for a given walking speed.  相似文献   

7.
Usually the measurement of multi-segment foot and ankle complex kinematics is done with stationary motion capture devices which are limited to use in a gait laboratory. This study aimed to propose and validate a wearable system to measure the foot and ankle complex joint angles during gait in daily conditions, and then to investigate its suitability for clinical evaluations. The foot and ankle complex consisted of four segments (shank, hindfoot, forefoot, and toes), with an inertial measurement unit (3D gyroscopes and 3D accelerometers) attached to each segment. The angles between the four segments were calculated in the sagittal, coronal, and transverse planes using a new algorithm combining strap-down integration and detection of low-acceleration instants. To validate the joint angles measured by the wearable system, three subjects walked on a treadmill for five minutes at three different speeds. A camera-based stationary system that used a cluster of markers on each segment was used as a reference. To test the suitability of the system for clinical evaluation, the joint angle ranges were compared between a group of 10 healthy subjects and a group of 12 patients with ankle osteoarthritis, during two 50-m walking trials where the wearable system was attached to each subject. On average, over all joints and walking speeds, the RMS differences and correlation coefficients between the angular curves obtained using the wearable system and the stationary system were 1 deg and 0.93, respectively. Moreover, this system was able to detect significant alteration of foot and ankle function between the group of patients with ankle osteoarthritis and the group of healthy subjects. In conclusion, this wearable system was accurate and suitable for clinical evaluation when used to measure the multi-segment foot and ankle complex kinematics during long-distance walks in daily life conditions.  相似文献   

8.
Wearable systems are becoming increasingly popular for gait assessment outside of laboratory settings. A single shoe-embedded sensor module can measure the foot progression angle (FPA) during walking. The FPA has important clinical utility, particularly in populations with knee osteoarthritis, as it is a target for biomechanical treatments. However, the validity and the day-to-day reliability of FPA measurement using wearable systems during over-ground walking has yet to be established. Two gait analysis sessions on 20 healthy adults were conducted. During both sessions, participants performed natural over-ground walking in a motion capture laboratory and on a 100 m linear section of outdoor athletics track. FPA was measured in the laboratory via marker trajectory data, while the sensor module measured FPA during the outdoor track walking. Validity was examined by comparing the laboratory- and sensor-measured average FPA. Day-to-day reliability was examined by comparing the sensor-measured FPA between the first and second gait analysis sessions. Average absolute error between motion capture and sensor measured FPA were 1.7° and 2.1° at session 1 and 2, respectively. A Bland and Altman plot indicated no systematic bias, with 95% limit of agreement widths of 4.2° – 5.1°. Intraclass correlation coefficient (ICC2k) analysis resulted in good to excellent validity (ICC = 0.89 – 0.91) and reliability (ICC = 0.95). Overall, the shoe-embedded sensor module is a valid and reliable method of measuring FPA during over-ground walking without the need for laboratory equipment.  相似文献   

9.
In gait analysis, the concepts of Euler and helical (screw) angles are used to define the three-dimensional relative joint angular motion of lower extremities. Reliable estimation of joint angular motion depends on the accurate definition and construction of embedded axes within each body segment. In this paper, using sensitivity analysis, we quantify the effects of uncertainties in the definition and construction of embedded axes on the estimation of joint angular motion during gait. Using representative hip and knee motion data from normal subjects and cerebral palsy patients, the flexion-extension axis is analytically perturbed +/- 15 degrees in 5 degrees steps from a reference position, and the joint angles are recomputed for both Euler and helical angle definitions. For the Euler model, hip and knee flexion angles are relatively unaffected while the ab/adduction and rotation angles are significantly affected throughout the gait cycle. An error of 15 degrees in the definition of flexion-extension axis gives rise to maximum errors of 8 and 12 degrees for the ab/adduction angle, and 10-15 degrees for the rotation angles at the hip and knee, respectively. Furthermore, the magnitude of errors in ab/adduction and rotation angles are a function of the flexion angle. The errors for the ab/adduction angles increase with increasing flexion angle and for the rotation angle, decrease with increasing flexion angle. In cerebral palsy patients with flexed knee pattern of gait, this will result in distorted estimation of ab/adduction and rotation. For the helical model, similar results are obtained for the helical angle and associated direction cosines.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
A computer simulation technique was applied to make clear the mechanical characteristics of primate bipedal walking. A primate body and the walking mechanism were modeled mathematically with a set of dynamic equations. Using a digital computer, the following were calculated from these equations by substituting measured displacements and morphological data of each segment of the primate: the acceleration, joint angle, center of gravity, foot force, joint moment, muscular force, transmitted force at the joint, electric activity of the muscle, generated power by the leg and energy expenditure in walking.The model was evaluated by comparing some of the calculated results with the experimental results such as foot force and electromyographic data, and improved in order to obtain the agreement between them.The level bipedal walking of man, chimpanzee and Japanese monkey and several types of synthesized walking were analyzed from the viewpoint of biomechanics.It is concluded that the bipedal walking of chimpanzee is nearer to that of man than to that of the Japanese monkey because of its propulsive mechanism, but it requires large muscular force for supporting the body weight.  相似文献   

11.
The availability of age-matched normative data is an essential component of clinical gait analyses. Comparison of normative gait databases is difficult due to the high-dimensionality and temporal nature of the various gait waveforms. The purpose of this study was to provide a method of comparing the sagittal joint angle data between two normative databases. We compared a modern gait database to the historical San Diego database using statistical classifiers developed by Tingley et al. (2002). Gait data were recorded from 60 children aged 1–13 years. A six-camera Vicon 512 motion analysis system and two force plates were utilized to obtain temporal-spatial, kinematic, and kinetic parameters during walking. Differences between the two normative data sets were explored using the classifier index scores, and the mean and covariance structure of the joint angle data from each lab. Significant differences in sagittal angle data between the two databases were identified and attributed to technological advances and data processing techniques (data smoothing, sampling, and joint angle approximations). This work provides a simple method of database comparison using trainable statistical classifiers.  相似文献   

12.
The purpose of this feasibility study was to examine changes in frontal plane knee and hip walking biomechanics following a gait retraining strategy focused on increasing lateral trunk lean and to quantify reports of difficulty and joint discomfort when performing such a gait modification. After undergoing a baseline analysis of normal walking, 9 young, healthy participants were trained to modify their gait to exhibit small (4°), medium (8°), and large (12°) amounts of lateral trunk lean. Training was guided by the use of real-time biofeedback of the actual trunk lean angle. Peak frontal plane external knee and hip joint moments were compared across conditions. Participants were asked to report the degree of difficulty and the presence of any joint discomfort for each amount of trunk lean modification. Small (4°), medium (8°), and large (12°) amounts of lateral trunk lean reduced the peak external knee adduction moment (KAM) by 7%, 21%, and 25%, respectively, though the peak KAM was only significantly less in the medium and large conditions (p<0.001). Increased trunk lean also significantly reduced the peak external hip adduction moments (p<0.001). All participants reported at least some difficulty performing the exaggerated trunk lean pattern and three participants reported ipsilateral knee, hip, and/or lower spine discomfort. Results from this study indicate that a gait pattern with increased lateral trunk lean can effectively reduce frontal plane joint moments. Though these findings have implications for pathological populations, learning this gait pattern was associated with some difficulty and joint discomfort.  相似文献   

13.
We developed and evaluated a new kinematic driver for musculoskeletal models using ambulatory inertial and magnetic measurement units (IMMUs). The new driver uses the orientation estimates based on sensor fusion of each individual IMMU and benefits from two important properties of musculoskeletal models. First, these models contain more complex, anatomical, kinematic models than those currently used for sensor fusion of multiple IMMUs and are continuously improved. Second, they allow movement between segment and measured sensor. For three different tasks, the new IMMU driver, (optical) marker drivers and a combination of both were used to reconstruct the motion. Maximal root mean square (RMS) joint angle differences with respect to the silver standard (combined IMMU/marker drivers) were found for the hip joint; 4°, 2° and 5° during squat, gait and slideboard tasks for IMMU-driven reconstructions, compared with 6°, 5° and 5° for marker-driven reconstructions, respectively. The measured angular velocities corresponded best to the IMMU-driven reconstructions, with a maximal RMS difference of 66°/s, compared with 108°/s and 91°/s for marker-driven reconstructions and silver standard. However, large oscillations in global accelerations occurred during IMMU-driven reconstructions resulting in a maximal RMS difference with respect to measured acceleration of 23 m/s2, compared with 9 m/s2 for reconstructions that included marker drivers. The new driver facilitates direct implementation of IMMU-based orientation estimates in currently available biomechanical models. As such, it can help in the rapid expansion of biomechanical analysis based on outdoor measurements.  相似文献   

14.
Hip contact forces and gait patterns from routine activities.   总被引:35,自引:0,他引:35  
In vivo loads acting at the hip joint have so far only been measured in few patients and without detailed documentation of gait data. Such information is required to test and improve wear, strength and fixation stability of hip implants. Measurements of hip contact forces with instrumented implants and synchronous analyses of gait patterns and ground reaction forces were performed in four patients during the most frequent activities of daily living. From the individual data sets an average was calculated. The paper focuses on the loading of the femoral implant component but complete data are additionally stored on an associated compact disc. It contains complete gait and hip contact force data as well as calculated muscle activities during walking and stair climbing and the frequencies of daily activities observed in hip patients. The mechanical loading and function of the hip joint and proximal femur is thereby completely documented. The average patient loaded his hip joint with 238% BW (percent of body weight) when walking at about 4 km/h and with slightly less when standing on one leg. This is below the levels previously reported for two other patients (Bergmann et al., Clinical Biomechanics 26 (1993) 969-990). When climbing upstairs the joint contact force is 251% BW which is less than 260% BW when going downstairs. Inwards torsion of the implant is probably critical for the stem fixation. On average it is 23% larger when going upstairs than during normal level walking. The inter- and intra-individual variations during stair climbing are large and the highest torque values are 83% larger than during normal walking. Because the hip joint loading during all other common activities of most hip patients are comparably small (except during stumbling), implants should mainly be tested with loading conditions that mimic walking and stair climbing.  相似文献   

15.
The purpose of this study was to predict and explain the pattern of shear force and ligament loading in the ACL-deficient knee during walking, and to compare these results to similar calculations for the healthy knee. Musculoskeletal modeling and computer simulation were combined to calculate ligament forces in the ACL-deficient knee during walking. Joint angles, ground-reaction forces, and the corresponding lower-extremity muscle forces obtained from a whole-body dynamic optimization simulation of walking were input into a second three-dimensional model of the lower extremity that represented the knee as a six degree-of-freedom spatial joint. Anterior tibial translation (ATT) increased throughout the stance phase of gait when the model ACL was removed. The medial collateral ligament (MCL) was the primary restraint to ATT in the ACL-deficient knee. Peak force in the MCL was three times greater in the ACL-deficient knee than in the ACL-intact knee; however, peak force sustained by the MCL in the ACL-deficient knee was limited by the magnitude of the total anterior shear force applied to the tibia. A decrease in anterior tibial shear force was brought about by a decrease in the patellar tendon angle resulting from the increase in ATT. These results suggest that while the MCL acts as the primary restraint to ATT in the ACL-deficient knee, changes in patellar tendon angle reduce total anterior shear force at the knee.  相似文献   

16.
A three-dimensional model for normal gait formulated in Part 1 is now altered to simulate the dynamics of pathological walking. Mechanisms fundamental to the production of a normal gait pattern are systematically removed, in order to assess contributions from individual gait determinants. Four separate pathological cases are studied: a model neglecting ankle plantarflexor activity; absence of stance knee flexion-extension and foot and knee interaction; both pelvic list and transverse pelvic rotation removed; and finally, a model with all major gait determinants missing. These are used collectively to show that stance knee flexion-extension and foot and knee interaction successively dominate lower-extremity dynamical response during the single support phase of normal gait. The hip abductor muscles, while effecting pelvic list, serve to stabilize this limb, rather than actively determine whole-body vertical acceleration. Mechanisms compensating for a loss in joint motion are also explored. Complete ankle loss may be successfully compensated with increased hip abductor muscle activity; the loss of both ankle and knee, however, demand unacceptable levels of vertical pelvic displacement.  相似文献   

17.
For the control of actuated orthoses, or gait rehabilitation robotics, kinematic reference trajectories are often required. These trajectories, consisting of joint angles, angular velocities and accelerations, are highly dependent on walking-speed. We present and evaluate a novel method to reconstruct body-height and speed-dependent joint trajectories. First, we collected gait kinematics in fifteen healthy (middle) aged subjects (47–68), at a wide range of walking-speeds (0.5–5 kph). For each joint trajectory multiple key-events were selected (among which its extremes). Second, we derived regression-models that predict the timing, angle, angular velocity and acceleration for each key-event, based on walking-speed and the subject?s body-height. Finally, quintic splines were fitted between the predicted key-events to reconstruct a full gait cycle. Regression-models were obtained for hip ab-/adduction, hip flexion/extension, knee flexion/extension and ankle plantar-/dorsiflexion. Results showed that the majority of the key-events were dependent on walking-speed, both in terms of timing and amplitude, whereas the body-height had less effect. The reconstructed trajectories matched the measured trajectories very well, in terms of angle, angular velocity and acceleration. For the angles the RMSE between the reconstructed and measured trajectories was 2.6°. The mean correlation coefficient between the reconstructed and measured angular trajectories was 0.91. The method and the data presented in this paper can be used to generate speed-dependent gait patterns. These patterns can be used for the control of several robotic gait applications. Alternatively they can assist the assessment of pathological gait, where they can serve as a reference for “normal” gait.  相似文献   

18.
Modern three-dimensional gait analysis systems give information on joint angles and moments in the sagittal and coronal planes, for which normal ranges may not be readily available in the literature. Since patients with joint disease tend to walk slowly and with a short stride, it is essential that normal ranges for gait parameters should be defined with reference to speed of walking. This we have done using a population of 10 normal male subjects agea from 18 to 63 years, walking at speeds which range from very slow to very fast. The ranges of knee angle and moment are given, together with the changes in these parameters with walking speed. Peak knee flexion moment is strongly related to walking speed, whereas coronal plane knee angle is virtually independent of it. The stride length is probably the best basis for deciding the normal range for a particular measurement.  相似文献   

19.
During human walking, plantar flexor activation in late stance helps to generate a stable and economical gait pattern. Because plantar flexor activation is highly mediated by proprioceptive feedback, the nervous system must modulate reflex pathways to meet the mechanical requirements of gait. The purpose of this study was to quantify ankle joint mechanical output of the plantar flexor stretch reflex response during a novel unexpected gait perturbation. We used a robotic ankle exoskeleton to mechanically amplify the ankle torque output resulting from soleus muscle activation. We recorded lower-body kinematics, ground reaction forces, and electromyography during steady-state walking and during randomly perturbed steps when the exoskeleton assistance was unexpectedly turned off. We also measured soleus Hoffmann- (H-) reflexes at late stance during the two conditions. Subjects reacted to the unexpectedly decreased exoskeleton assistance by greatly increasing soleus muscle activity about 60 ms after ankle angle deviated from the control condition (p<0.001). There were large differences in ankle kinematic and electromyography patterns for the perturbed and control steps, but the total ankle moment was almost identical for the two conditions (p=0.13). The ratio of soleus H-reflex amplitude to background electromyography was not significantly different between the two conditions (p=0.4). This is the first study to show that the nervous system chooses reflex responses during human walking such that invariant ankle joint moment patterns are maintained during perturbations. Our findings are particularly useful for the development of neuromusculoskeletal computer simulations of human walking that need to adjust reflex gains appropriately for biomechanical analyses.  相似文献   

20.
Our purpose was to demonstrate the ability of an actively controlled partial body weight support (PBWS) system to provide gait synchronized support during the stance period of a single lower extremity while examining the affect of such a support condition on gait asymmetry. Using an instrumented treadmill and a motion capture system, we compared gait parameters of twelve healthy elderly subjects (age 65-80 years) during unsupported walking to those while walking with 20% body weight support provided during only the stance period of the right limb. Specifically, we examined peak three-dimensional ground reaction force (GRF) data and the symmetry of lower extremity sagittal plane joint angles and of time and distance parameters. A reduction in all three GRF components was observed for the supported limb during modulated support. Reductions observed in the vertical GRF were comparable to the desired 20% support level. Additionally, GRF components examined for the unsupported limb during modulated support were consistently similar to those measured during unsupported walking. Modulated support caused statistically significant increases in asymmetry for knee flexion during stance (increased 5.9%), hip flexion during late swing (increased 9.1%), and the duration of single limb support (increased 2.8%). However, the observed increases were similar or considerably less than the natural variability in the asymmetry of these parameters during unsupported walking. The ability of the active PBWS device to provide unilateral support may offer new and possibly improved applications of PBWS rehabilitation for patients with unilateral walking deficits such as hemiparesis or orthopaedic injury.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号