首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary Although the presence of magnetite in their tissues is correlated with the ability of different species to detect magnetic fields, proof that the magnetite is involved in magnetoreception has not yet been provided. Using the approach employed to localize and isolate magnetic particles in the yellowfin tuna, we found that single-domain magnetite occurs in chains of particles in tissue contained within the dermethmoid cartilage of adult chinook salmon,Oncorhynchus tshawytscha. The particles are present in sufficient numbers to provide the adult fish with a very sensitive magnetoreceptor system. Magnetite in the chinook can be correlated with responses to magnetic fields in a congeneric species, the sockeye salmon. Based on the presence of the chains of particles, we propose behavioral experiments that exploit the responses of sockeye salmon fry to magnetic fields to test explicit predictions of the ferromagnetic magnetoreception hypothesis.  相似文献   

2.
Body tissues are not ferromagnetic, but ferromagnetic particles can be present as contaminants or as probes in the lungs and in other organs. The magnetic domains of these particles can be aligned by momentary application of an external magnetic field; the magnitude and time course of the resultant remanent field depend on the quantity of magnetic material and the degree of particle motion. The interpretation of magnetometric data requires an understanding of particle magnetization, agglomeration, random motion, and both rotation and translation in response to magnetic fields. We present physical principles relevant to magnetometry and suggest models for intracellular particle motion driven by thermal, elastic, or cellular forces. The design principles of instrumentation for magnetizing intracellular particles and for detecting weak remanent magnetic fields are described. Such magnetic measurements can be used for noninvasive studies of particle clearance from the body or of particle motion within body tissues and cells. Assumptions inherent to this experimental approach and possible sources of artifact are considered and evaluated.  相似文献   

3.
Physiologic magnetic fields of the order 10(-8) gauss have been unified with their propitiators: quantum genetic particles, the gravitational potential of which is about an erg. As these fields are applied to the equation for solenoidal models, B = micro NI/L, currents of about a microampere are derived; in perfect accord with recent clinical data indicating the therapeutic efficacy of weak currents in repair and growth of soft tissue, bone and nerve. The mechanism of reorientation of spin angular momentum of leptons and baryons influencing molecular magnetic domains to bring about 'particle jumps' is presented so that a clinical picture results. The clinical picture is that of an organism placed at right angles to flux lines in the midst of a solenoid immersed in water exposed then to exogenously applied resonant physiologic magnetic fields which convert malalligned atomic lattices of oncogenes and associated particles to homologous normal structures.  相似文献   

4.
The motions of magnetic particles contained within organelles of living cells were followed by measuring magnetic fields generated by the particles. The alignment of particles was sensed magnetometrically and was manipulated by external fields, allowing non-invasive detection of particle motion as well as examination of cytoplasmic viscoelasticity. Motility and rheology data are presented for pulmonary macrophages isolated from lungs of hamsters 1 d after the animals had breathed airborne gamma-Fe2O3 particles. The magnetic directions of particles within phagosomes and secondary lysosomes were aligned, and the weak magnetic field produced by the particles was recorded. For dead cells, this remanent field was constant, but for viable macrophages, the remanent field decreased rapidly so that only 42% of its initial magnitude remained 5 min after alignment. A twisting field was applied perpendicular to the direction of alignment and the rate at which particles reoriented to this new direction was followed. The same twisting was repeated for particles suspended in a series of viscosity standards. Based on this approach, the low-shear apparent intracellular viscosity was estimated to be 1.2-2.7 X 10(3) Pa.s (1.2-2.7 X 10(4) poise). Time-lapse video microscopy confirmed the alignment of ingested particles upon magnetization and showed persistent cellular motility during randomization of alignment. Cytochalasin D and low temperature both reduced cytoplasmic activity and remanent-field decay, but affected rheology differently. Magnetic particles were observed in association with the microtubule organizing center by immunofluorescence microscopy; magnetization did not affect microtubule distribution. However, both vimentin intermediate filaments and f-actin reorganized after magnetization. These data demonstrate that magnetometry of isolated phagocytic cells can probe organelle movements, rheology, and physical properties of the cytoskeleton in living cells.  相似文献   

5.
A new method to affect cells by cell–surface interaction is introduced. Biocompatible magnetic nanobeads are deposited onto a biocompatible magnetic thin layer. The particles are composed of small magnetite crystals embedded in a matrix which can be functionalized by different molecules, proteins or growth factors. The magnetic interaction between surface and beads prevents endocytosis if the setup is utilized for cell culturing. The force acting between particles and magnetic layer is calculated by a magnetostatic approach. Biocompatibility is ensured by using garnet layers which turned out to be nontoxic and stable under culturing conditions. The garnet thin films exhibit spatially and temporally variable magnetic domain configurations in changing external magnetic fields and depending on their thermal pretreatment. Several patterns and bead deposition methods as well as the cell–surface interactions were analyzed. In some cases the cells show directed growth. Theoretical considerations explaining particular cell behavior on this magnetic material involve calculations of cell growth on elastic substrates and bending of cell membranes.  相似文献   

6.
Magnetopneumography (MPG) as a non‐invasive method for pneumoconiosis diagnosis has been developed to evaluate the load and spatial distribution of particles within the human lungs through scanning of remanent magnetic fields after magnetization of the subject in a strong direct current field. The measurement of particle spatial distribution is very important for pneumoconiosis diagnosis because localized deposits may be associated with some pathological changes such as pulmonary fibrosis. Previous research found that loads of magnetite particles were proportional to their magnetic dipole moments. The three‐dimensional (3D) MPG magnetic dipole model (MDM) proposed in this paper and based on Biot–Savart Law and matrix manipulation provides a means of precise measurement of the particle distribution and load amount. A styrofoam + magnetite powder phantom with magnetization was laid on a nonmagnetic board. Two first‐order fluxgate gradiometers with 10–12 T sensitivity were coaxially applied over and under the phantom and used for scanning remanent magnetic fields. This paper provides validation results using 3D MPG MDM through two experiments. The overall error of the simulation results is 0.2–2.7% in the center and 7.28–9.42% in the corners of the subject. Finally, this paper gives clinical experiments with a welder suffering stage‐II pneumoconiosis and states that the 3D MPG MDM shows similar results to X‐ray chest films in pneumoconiosis diagnosis. The results suggest that the 3D MPG MDM is potentially a reasonable and accurate algorithmic model to inversely track the load amount and distribution of magnetite particles within the lungs. Bioelectromagnetics. 2019;40:472–487. © 2019 Wiley Periodicals, Inc  相似文献   

7.
A hypothesis is suggested to explain the inhibiting effect which magnetic fields have on the growth rate of cells. The mechanism is based on the influence a magnetic field has on the diffusion of charged particles. Electric fields originating within the cell are used to simulate an active transport mechanism. Estimates indicate that the dynamics of cells with charged cytoplasms are significantly perturbed by magnetic fields of the order of 10(5) gauss.  相似文献   

8.
Magnetic particles have been used widely in both biotechnological and medical fields, including for immunoassay, enzyme immobilization, drug transport, and immunological diagnosis. Especially particles with bioactive molecules such as antibodies and streptavidin are very useful tools for cell separation. Here we report affinity selection of neutrophils and macrophages from peritoneal inflammatory cells performed by thermoresponsive magnetic nanoparticles conjugated with macrophage-specific anti-F4/80 antibody. The magnetic nanoparticles, which are capped with thermoresponsive polymers, are aggregated by heating the particles over 30 degrees C and show their intrinsic magnetism. The neutrophils are concentrated approximately 90% by these magnetic nanoparticles without any activation, indicating that this novel cell separation method could fulfill a wide range of applications in analysis of the isolation of fragile cells such as neutrophils.  相似文献   

9.
The in vivo targeting of tumors with magnetic microspheres is currently realized through the application of external non-uniform magnetic fields generated by rare-earth permanent magnets or electromagnets. Our theoretical work suggests a feasible procedure for local delivery of magnetic nano- and microparticles to a target area. In particular, thin magnetizable wires placed throughout or close to the target area and magnetized by a perpendicular external uniform background magnetic field are used to concentrate magnetic microspheres injected into the target organ's natural blood supply. The capture of the magnetic particles and the building of deposits thereof in the blood vessels of the target area were modeled under circumstances similar to the in vivo situation. This technique could be applied to magnetically targeted cancer therapy or magnetic embolization therapy with magnetic particles that contain anticancer agents, such as chemotherapeutic drugs or therapeutic radioisotopes.  相似文献   

10.
We observed that particles, suspended in an electrolyte and brought into crossed magnetic and electric fields of low intensities, will deviate in the central part of the electrophoresis chamber of a standard Zeiss Cytopherometer with a component vertical to both fields. The direction and magnitude, however, were sharply at variance with what would be expected by the action of the Lorentz force (EMF) on the surface of the particles. The magnitude of the deviation depends upon the magnetic and electric field strength, the ion concentration of the suspension medium and the geometry of the chamber. The movement of the particles is due to streaming of the electrolyte which is mainly caused by inhomogeneities of the electric field in the electrophoresis chamber. The magnitude of the effect is high enough to occur under physiological conditions. Magneto-electrophoretic streaming might eventually act as a transducer mechanism which could explain the ability of some animals to orientate themselves in the geomagnetic field.  相似文献   

11.
We observed that particles, suspended in an electrolyte and brought into crossed magnetic and electric fields of low intensities, will deviate in the central part of the electrophoresis chamber of a standard Zeiss Cytopherometer with a component vertical to both fields. The direction and magnitude, however, were sharply at variance with what would be expected by the action of the Lorentz force (EMF) on the surface of the particles. The magnitude of the deviation depends upon the magnetic and electric field strength, the ion concentration of the suspension medium and the geometry of the chamber. The movement of the particles is due to streaming of the electrolyte which is mainly caused by inhomogeneities of the electric field in the electrophoresis chamber. The magnitude of the effect is high enough to occur physiological conditions. Magneto-electrophoretic streaming might eventually act as a transducer mechanism which could explain the ability of some animals to orientate themselves in the geomagnetic field.  相似文献   

12.
Collisionless confinement of monoenergetic α particles in three-dimensional magnetic fields produced by the magnetic coils of the Large Helical Device is calculated. It is found that the inward shift of the magnetic axis due to the vertical field improves the α-particle confinement. In contrast to the vertical field, both large positive and negative hexapole fields do not improve the confinement. The study of the β effect and Mercier criterion calculations for different hexapole fields are also presented.  相似文献   

13.
概述了磁细菌的特点及由磁细菌所产生的细菌磁颗粒的晶体成分、形态特征、磁颗粒膜的特点以及细菌磁颗粒在信息贮存、磁性细胞制备、基因研究、生物活性物质载体、免疫检测以及在污水处理、矿物分选等方面的应用研究。  相似文献   

14.

Background

For clinical applications of mesenchymal stem cells (MSCs), labeling and tracking is crucial to evaluate cell distribution and homing. Magnetic resonance imaging (MRI) has been successfully established detecting MSCs labeled with superparamagnetic particles of iron oxide (SPIO). Despite initial reports that labeling of MSCs with SPIO is safe without affecting the MSC's biology, recent studies report on influences of SPIO-labeling on metabolism and function of MSCs. Exposition of cells and tissues to high magnetic fields is the functional principle of MRI. In this study we established innovative labeling protocols for human MSCs using clinically established SPIO in combination with magnetic fields and investigated on functional effects (migration assays, quantification of colony forming units, analyses of gene and protein expression and analyses on the proliferation capacity, the viability and the differentiation potential) of magnetic fields on unlabeled and labeled human MSCs. To evaluate the imaging properties, quantification of the total iron load per cell (TIL), electron microscopy, and MRI at 3.0 T were performed.

Results

Human MSCs labeled with SPIO permanently exposed to magnetic fields arranged and grew according to the magnetic flux lines. Exposure of MSCs to magnetic fields after labeling with SPIO significantly enhanced the TIL compared to SPIO labeled MSCs without exposure to magnetic fields resulting in optimized imaging properties (detection limit: 1,000 MSCs). Concerning the TIL and the imaging properties, immediate exposition to magnetic fields after labeling was superior to exposition after 24 h. On functional level, exposition to magnetic fields inhibited the ability of colony formation of labeled MSCs and led to an enhanced expression of lipoprotein lipase and peroxisome proliferator-activated receptor-γ in labeled MSCs under adipogenic differentiation, and to a reduced expression of alkaline phosphatase in unlabeled MSCs under osteogenic differentiation as detected by qRT-PCR. Moreover, microarray analyses revealed that exposition of labeled MSCs to magnetic fields led to an up regulation of CD93 mRNA and cadherin 7 mRNA and to a down regulation of Zinc finger FYVE domain mRNA. Exposition of unlabeled MSCs to magnetic fields led to an up regulation of CD93 mRNA, lipocalin 6 mRNA, sialic acid acetylesterase mRNA, and olfactory receptor mRNA and to a down regulation of ubiquilin 1 mRNA. No influence of the exposition to magnetic fields could be observed on the migration capacity, the viability, the proliferation rate and the chondrogenic differentiation capacity of labeled or unlabeled MSCs.

Conclusions

In our study an innovative labeling protocol for tracking MSCs by MRI using SPIO in combination with magnetic fields was established. Both, SPIO and the static magnetic field were identified as independent factors which affect the functional biology of human MSCs. Further in vivo investigations are needed to elucidate the molecular mechanisms of the interaction of magnetic fields with stem cell biology.  相似文献   

15.
Targeted delivery of cells and therapeutic agents would benefit a wide range of biomedical applications by concentrating the therapeutic effect at the target site while minimizing deleterious effects to off-target sites. Magnetic cell targeting is an efficient, safe, and straightforward delivery technique. Superparamagnetic iron oxide nanoparticles (SPION) are biodegradable, biocompatible, and can be endocytosed into cells to render them responsive to magnetic fields. The synthesis process involves creating magnetite (Fe3O4) nanoparticles followed by high-speed emulsification to form a poly(lactic-co-glycolic acid) (PLGA) coating. The PLGA-magnetite SPIONs are approximately 120 nm in diameter including the approximately 10 nm diameter magnetite core. When placed in culture medium, SPIONs are naturally endocytosed by cells and stored as small clusters within cytoplasmic endosomes. These particles impart sufficient magnetic mass to the cells to allow for targeting within magnetic fields. Numerous cell sorting and targeting applications are enabled by rendering various cell types responsive to magnetic fields. SPIONs have a variety of other biomedical applications as well including use as a medical imaging contrast agent, targeted drug or gene delivery, diagnostic assays, and generation of local hyperthermia for tumor therapy or tissue soldering.  相似文献   

16.
The possibility is demonstrated of splitting the eigenfrequencies of MHD plasma waves in a stellarator with a weakly rippled helical confining magnetic field. The distribution of the fields of an Alfvén wave in the satellite Alfvén resonance region is investigated when the influence of the helical ripple in a confining magnetic field on the resonance structure is comparable with the effects of the finite ion Larmor radius, electron inertia, and collisions between plasma particles.  相似文献   

17.
趋磁细菌及其应用于生物导航的研究进展   总被引:2,自引:2,他引:0       下载免费PDF全文
趋磁性细菌是一种由于体内含有对磁场具有敏感性的磁小体,而能够沿着磁力线运动的特殊细菌,本文综述了趋磁细菌的分布、分类、特性、磁小体研究以及趋磁细菌在生物导航方面的研究进展。  相似文献   

18.
何世颖  顾宁 《生物磁学》2006,6(1):19-21
趋磁性细菌是一种由于体内含有对磁场具有敏感性的磁小体,而能够沿着磁力线运动的特殊细菌,本文综述了趋磁细菌的分布、分类、特性、磁小体研究以及趋磁细菌在生物导航方面的研究进展.  相似文献   

19.
To investigate the effects of pulsed magnetic field on magnetosome formation in Magnetospirillum magneticum AMB-1, cultures inoculated with either mangetic or non-magnetic pre-cultures were incubated under 1 mT pulsed magnetic field. Magnetism of cells was measured by using spectrophotometer coupled with applied magnetic fields and the values were described as C mag. Magnetosome in cells was counted by transmission electron microscopy observation. The results showed that pulsed magnetic field did not affect cellular growth, but enhanced magnetosome formation. The applied pulsed magnetic field might exceed the chain of magnetosomes and change the homogeneity of the magnetosome particles. The results implied that magnetite precipitation induced by the adjacent magnetosome was affected by pulsed magnetic field. Moreover, the applied pulsed magnetic field up-regulated the magA and mamA expression in cells, which might account for the increasing number and the exceeding chain of magnetosomes in cells.  相似文献   

20.
Magnetic particles have attracted much attention for their versatile uses in biotechnology, especially in medical applications. The major advantage of magnetic particles is that they can be easily manipulated by magnetic forces. Magnetotactic bacteria synthesize nano-sized biomagnetites, otherwise known as bacterial magnetic particles (BacMPs) that are individually enveloped by a lipid bilayer membrane. The mechanisms of BacMP synthesis have been analyzed by genomic, proteomic, and bioinformatic approaches. Based on those studies in Magnetospirillum magneticum AMB-1, functional nanomaterials have been designed and produced. Through genetic engineering, functional proteins such as enzymes, antibodies, and receptors have been successfully displayed on BacMPs. These functional BacMPs have been utilized in various biosensors and bio-separation processes. Here, recent papers and patents for bioengineering of BacMPs and their applications in biotechnology are reviewed. The elucidation of the mechanism of magnetic particle synthesis has provided a roadmap for the design of novel biomaterials that can play useful roles in multiple disciplinary fields.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号