首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Oestrogens, such as oestrone (E1), 17β-oestradiol (E2), oestriol (E3) and their biologically active metabolites 2-methoxyoestrone (2-MeOE1), 2-hydroxyoestradiol (2-OHE2) 16-ketooestradiol (16-OE2), 16-epioestriol (16-epiE3), as well as testosterone (T) play an important role in physiological and pathological developmental processes during human development. We therefore aimed at developing an isotope dilution/bench top gas chromatography–mass spectrometry (ID/GC–MS) method, based on benchtop GC–MS, for the simultaneous determination (‘profiling’) of the above analytes in children. The method consisted of equilibration of urine (5 ml) with a cocktail containing stable isotope-labelled analogues of the analytes as internal standards ([2,4-2H2]E1, [2,4,16,16-2H4]E2, [2,4,17-2H3]E3, [16,16,17-2H3]T, [1,4,16,16-2H4]2-MeOE1, [1,4,16,16,17-2H5]2-OHE2, [2,4,15,15,17-2H5]16-OE2 and [2,4-2H2]16-epiE3). Then, solid-phase extraction (C18 cartridges), enzymatic hydrolysis (sulphatase from Helix pomatia (type H-1)), re-extraction, purification by anion exchange chromatography and derivatisation to trimethylsilyl ethers followed. The samples were analysed by GC–MS (Agilent GC 6890N/5975MSD; fused silica capillary column 25 m × 0.2 mm i.d., film 0.10 μm). Calibration plots were linear and showed excellent reproducibility with coefficients of determination (r2) between 0.999 and 1.000. Intra- and inter-assay coefficients of variation (CV) were <2.21% for all quantified metabolites. Sensitivity was highest for 2-OHE2 (0.25 pg per absolute injection: signal-to-noise ratio (S/N) = 3) and lowest for 16-epiE3 (2 pg per absolute injection: S/N = 2.6), translating into corresponding urine sample analyte concentrations of 0.025 ng ml?1 and 0.2 ng ml?1, respectively. Accuracy – determined in a two-level spike experiment – showed relative errors ranging between 0.15% for 16-OE2 and 11.63% for 2-OHE2. Chromatography showed clear peak shapes for the components analysed. In summary, we describe a practical, sensitive and specific ID/GC–MS assay capable of profiling the above-mentioned steroids in human urine from childhood onwards.  相似文献   

2.
Oxidative stress is associated with many disease states including gynecologic disease. This process can damage lipids, proteins and DNA. The present study highlights the role of oxidative stress induced DNA damage as measured by 8-hydroxy-2-deoxyguanosine in development of benign gynecological conditions (BGC). Our aim was to map the oxidative DNA damage on female reproductive organs and highlight the high amount found in a variety of benign gynecologic disorders. Seventeen biopsy specimens from female pelvic organs were divided in two groups: healthy organs tissue and BGC tissue. Healthy organs biopsy tissue included the cervix, tubes, uterus, peritoneum, and topic endometrium in secretory phase. Benign gynecological biopsy tissue included hydrosalpinges, leiomyoma, adenomyosis and tubal cysts. Immunohistochemical staining showed significantly higher levels of DNA damage between BGC and healthy organs [19.36 % (6.20; 32.51) vs. 4.61 % (0.63; 8.53); P < 0.0344]. Our results highlight the involvement of oxidative stress DNA damage in female benign pelvic disease. Hydrosalpinges, leiomyoma, and adenomyosis exhibit the highest amounts of oxidative DNA damage in the pelvic cavity.  相似文献   

3.
A GC–MS assay for stereoselective determination of tramadol and its pharmacologically active phase I metabolite O-desmethyltramadol in human urine was developed. Nefopam was used as internal standard. The method involves a simple solid phase extraction with chiral analysis by gas chromatography–electron ionization mass spectrometry using m/z 263; 58, 249; 58, and 179; 58 for the determination of concentration of tramadol, O-desmethyltramadol and internal standard, respectively. Chromatography was performed on a Rt-βDEXcst column containing alkylated beta-cyclodextrins as a chiral selector. The calibration curves were linear in the concentration range 0.1–20 μg/mL (R2  0.998). Intra-day accuracies ranged between 97.2–104.9%, 96.1–103.2%, and 97.3–102.8% at the lower, intermediate, and high concentration for all analytes, respectively. Inter-day accuracies ranged between 95.2–105.7%, 99.1–105.2%, and 96.5–101.2% at the lower, intermediate, and high concentration for all analytes, respectively. This method was successfully used to determine the concentration of enantiomers of T and ODT in a pharmacogenetic study.  相似文献   

4.
Liquid chromatography–thermospray mass spectrometry (LC–TSP-MS) using isotope dilution was investigated for quantitative analysis of cortisol, cortisone, prednisolone and prednisone in human plasma. Complete separation attained by a LiChroCART Supersupher reversed-phase column and elution with 0.05 M ammonium formate–tetrahydrofuran–methanol (180:53:17, v/v/v) resulted in a significantly large isotope effect of the deuterium-labeled analogs on the HPLC behavior and caused difficulty in quantification. Reduction of the isotope effect on the retention times using 0.05 M ammonium formate–acetonitrile (65:35, v/v) permitted accurate quantification of cortisol and cortisone by the isotope dilution LC–TSP-MS, although separation between cortisol and prednisone was incomplete.  相似文献   

5.
A simple and sensitive method is proposed for the determination of seven low-molecular mass aldehydes in human urine samples using liquid chromatography with tandem mass spectrometric detection. Urine samples diluted twofold with 0.3 M hydrochloric acid are aspirated into a LiChrolut EN solid-phase extraction column impregnated with 2,4-dinitrophenylhydrazine for cleanup, derivatization and preconcentration of the aldehydes. After elution of the hydrazones with acetonitrile, an aliquot is injected directly into the chromatograph. Identification and quantification of aldehydes was performed with electrospray in negative ion mode by selected reaction monitoring. By using synthetic urine samples, linearity is established over the concentration range 0.1–30 μg/l and limits of detection from 15 to 65 ng/l. The intra- and inter-day precision (RSD, %) of the aldehydes ranged from 2.9% to 6.4% and 3.6% to 9.3%, respectively, and specific uncertainties were ca. 5.0 ± 0.3 ng for all aldehydes. Average recoveries performed on two levels by enriching synthetic urine samples ranged between 92% and 100%. The method was also validated in terms of study sample stability including long-term and short-term analyte stability, freeze–thaw and extract stability. In summary, the method proposed surpasses other recent chromatographic alternatives in terms of the limit of detection and sample requirements for analysis.  相似文献   

6.
《Free radical research》2013,47(10):1291-1295
Abstract

Background. Measurement of urinary 8-hydroxy-2′-deoxyguanosine (8-OHdG) has recently become more popular as a means of assessing oxidative stress in the human body. The aim of this study is to compare the levels of urine 8-OHdG in patients with type 2 diabetes with and without nephropathy and to evaluate its role as a biochemical marker for distinguishing these patients from healthy and patients without complications. Methods. For this purpose, 52 patients with type 2 diabetes mellitus (32 with nephropathy (DMN), 20 without nephropathy (DM)) and 20 healthy control subjects (C) were included in this study. The urine concentrations of 8-OHdG were measured by modified LC-MS/MS method and compared with the first morning voiding urine albumin/creatinine ratio (UACR) and HbA1c values of the same patients. Results. The concentrations of urine 8-OHdG in DMN and DM patients were higher than those of the control subjects (3.47?±?0.94, 2.92?±?1.73, 2.1?±?0.93 nmol/mol creatinine, respectively). But there was no statistical difference between DMN and DM (p =?0.115). There is significant correlation between urinary 8-OHdG and UACR (r =?0.501, p <?0.001). According to ROC analysis, the AUC value of HbA1c was higher than the value of the AUC of 8-OHdG (0.882 and 0.771, respectively). Conclusions. This study shows that the urine 8-OHdG levels increase in diabetic patients. However, urinary 8-OHdG is not a useful clinical marker, compared with UACR, to predict the development of diabetic nephropathy in diabetic patients.  相似文献   

7.
A previously described method for the determination of GABA in CSF has been expanded to include both GABA and β-ALA, using a single GC–MS analysis. A stable isotope labelled internal standard for β-ALA was synthesised to achieve accurate quantification. This new combined method expands the diagnostic power compared to an isolated GABA measurement. Control values for free and total GABA and free and total β-ALA are described. Age <2 years: free GABA 0.017–0.067 μM, total GABA 4.2–13.4 μM; free β-ALA 0.049–0.11 μM, total β-ALA 2.1–4.6 μM. Age >2 years: free GABA 0.032–0.17 μM, total GABA 3.3–12.2 μM; free β-ALA 0.021–0.058 μM, total β-ALA 0.91–3.5 μM.  相似文献   

8.
In the present study, we used the method involving HPLC pre-purification followed by gas chromatography with isotope dilution mass spectrometric detection for the determination of 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodGuo) and 8-oxo-7,8-dihydroguanine (8-oxoGua) in human urine. The mean levels of 8-oxoGua and 8-oxodGuo in the urine samples of the subjects on unrestricted diet were respectively 1.87 nmol/kg 24 h (±0.90) and 0.83 nmol/kg 24h (±0.49), and in the case of the groups studied, they did not depend on the applied diet. The sum of the amounts of both compounds in urine can give information about the formation rate of 8-oxoGua in cellular DNA. It is also likely that the levels of modified nucleo-base/side in urine sample are reflective of the involvement of different repair pathways responsible for the removal of 8-oxodGuo from DNA, namely base excision repair (BER) and nucleotide excision repair (NER).  相似文献   

9.
Haloacetic acids (HAAs) are water disinfection byproducts (DBPs) formed by the reaction of chlorine oxidizing compounds with natural organic matter in water containing bromine. HAAs are second to trihalomethanes as the most commonly detected DBPs in surface drinking water and swimming pools. After oral exposure (drinking, showering, bathing and swimming), HAAs are rapidly absorbed from the gastrointestinal tract and excreted in urine. Typical methods used to determine these compounds in urine (mainly from rodents) only deal with one or two HAAs and their sensitivity is inadequate to determine HAA levels in human urine, even those manual sample preparation protocols which are complex, costly, and neither handy nor amenable to automation. In the present communication, we report on a sensitive and straightforward method to determine the nine HAAs in human urine using static headspace (HS) coupled with GC–MS. Important parameters controlling derivatisation and HS extraction were optimised to obtain the highest sensitivity: 120 μl of dimethylsulphate and 100 μl of tetrabutylammonium hydrogen sulphate (derivatisation regents) were selected, along with an excess of Na2SO4 (6 g per 12 ml of urine), an oven temperature of 70 °C and an equilibration time of 20 min. The method developed renders an efficient tool for the precise and sensitive determination of the nine HAAs in human urine (RSDs ranging from 6 to 11%, whereas LODs ranged from 0.01 to 0.1 μg/l). The method was applied in the determination of HAAs in urine from swimmers in an indoor swimming pool, as well as in that of non-swimmers. HAAs were not detected in the urine samples from non-swimmers and those of volunteers before their swims; therefore, the concentrations found after exposure were directly related to the swimming activity. The amounts of MCAA, DCAA and TCAA excreted from all swimmers are related to the highest levels in the swimming pool water.  相似文献   

10.
A high order method for measuring urea concentrations in milk and milk powder was developed. The method can be applied to certify the concentration of urea in some new milk and milk powder CRMs. This high accurate method for analysis of milk is valuable given the inherent challenges associated with the complexity of the sample matrix. A measurement procedure based on gas chromatography/isotope dilution mass spectrometry (GC/IDMS) was developed. Samples were pre-treated with acetonitrile to remove proteins and the method was applied to determine urea concentrations in milk and milk powder. Excellent precision was obtained, with within- and between-set coefficients of variation of 0.15–0.46 and 0.18–0.65%, respectively. The measurement uncertainty is evaluated. The method can trace to mass.  相似文献   

11.
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for the simultaneous determination of eight β-lactam antibiotics, including ampicillin, cefazolin, cefepime, cefmetazole, cefotaxime, doripenem, meropenem, and piperacillin, in human serum. Sample specimens were subjected to solid phase extraction (SPE) using Waters Oasis® HLB cartridges (30 mg). Chromatographic separation was performed with a high-resolution octadecyl silica column compatible with hydrophilic compounds, using a gradient of 10 mM aqueous ammonium formate containing 0.1% formic acid-methanol. Antibiotics were detected by a triple quadrupole mass spectrometer (MS/MS) with electrospray ionization and quantified by the multiple reaction monitoring mode. A total run time of 13 min was applied. Linearity in the calibration was obtained over a range of 0.1–50 μg/mL of the β-lactam antibiotics, except for doripenem. The lower limit of quantification was 0.005–0.5 μg/mL, using 50 μL serum. The recovery rate exceeded 80.2% for these analytes, except for doripenem (49.1%) and meropenem (62.3%). The present method is applicable to routine therapeutic monitoring of β-lactam antibiotics in clinical practice.  相似文献   

12.
13.
《Free radical research》2013,47(4):541-553
Abstract

Levels of oxidatively damaged cellular DNA and urinary excretion of damaged 2′-deoxyribonuclosides are widely measured in biomonitoring studies examining the role of oxidative stress induced by environmental exposures, lifestyle factors and development of disease. This has promoted efforts to harmonise measurements of oxidised guanine nucleobases by the variety of analytical approaches for DNA and urinary levels of damage, in multi-laboratory trials that are centred in Europe. The large inter-laboratory variation reported of values of oxidatively damaged DNA is reduced by harmonising assay protocols. Recent attention on optimal conditions for the comet assay may lead to better understanding of the most critical steps in procedure, which generate variation in DNA damage levels between laboratories. Measurements of urinary excretion of oxidatively generated 8-oxo-7,8-dihydro-2′-deoxyguanosine also show large differences between different methods, where chromatographic techniques generally show more reliable results than antibody-based methods. In this case, standardising calibrants is aimed at improving within technique agreement.  相似文献   

14.
A liquid chromatography–mass spectrometry (LC–MS) method for the analysis of corticosteroids in equine urine was developed. Corticosteroid conjugates were hydrolysed with β-glucuronidase; free and enzyme-released corticosteroids were then extracted from the samples with ethyl acetate followed by a base wash. The isolated corticosteroids were detected by LC–MS and confirmed by LC–MS–MS in the positive atmospheric pressure chemical ionisation mode. Twenty-three corticosteroids (comprising hydrocortisone, deoxycorticosterone and 21 synthetic corticosteroids), each at 5 ng/ml in urine, could easily be analysed in 10 min.  相似文献   

15.
A kinetic study of atosiban was conducted following repeated intravenous administration in Wistar rats. Sample analysis was performed using liquid chromatography–tandem mass spectrometry (LC–MS/MS) following full validation of an in-house method. Eptifibatide, a cyclic peptide, was used as an internal standard (IS). The analyte and internal standard were extracted using solid phase extraction (SPE) method. Chromatographic separation was carried out using an ACE C18 5 μm 50 mm × 4.6 mm column with gradient elution. Mass spectrometric detection was performed using TSQ Quantum ultra AM. The lower limit of quantification was 0.01 μg/ml when 100 μl rat plasma was used. Plasma concentrations of atosiban were measured at 0 (pre-dose), 2, 15, 30, 45, 60, 120 min at the dosage levels of 0.125 mg/kg (low dose), 0.250 mg/kg (mid dose), and 0.500 mg/kg (high dose), respectively. Atosiban plasma concentration measured at Day 1 showed mean peak atosiban concentration (Cmax) 0.40, 0.57, 1.95 μg/ml for low, mid and high dose treated animals and mean peak concentration on Day 28 was 0.41, 0.88, 1.31 μg/ml on Day 28 for low, mid and high dose treated animals.  相似文献   

16.
A simple, reliable and sensitive gas chromatographic–mass spectrometric method was devised to determine the level of mannitol in various human brain tissues obtained at autopsy. Mannitol was extracted with 10% trichloroacetic acid solution which effectively precipitated brain tissues. The supernatant was washed with tert.-butyl methyl ether to remove other organic compounds and to neutralize the aqueous solution. Mannitol was then derivatized with 1-butaneboronic acid and subjected to GC–MS. Erythritol was used as an internal standard. For quantitation, selected ion monitoring with m/z 127 and 253 for mannitol and m/z 127 for internal standard were used. Calibration curves were linear in concentration range from 0.2 to 20 μg/0.1 g and correlation coefficients exceeded 0.99. The lower detection limit of mannitol in distilled water was 1 ng/0.1 g. Mannitol was detected in control brain tissues, as a biological compound, at a level of 50 ng/0.1 g. The precision of this method was examined with use of two different concentrations, 2 and 20 μg/0.1 g, and the relative standard deviation ranged from 0.8 to 8.3%. We used this method to determine mannitol in brain tissues from an autopsied individual who had been clinically diagnosed as being brain dead. Cardiac arrest occurred 4 days later.  相似文献   

17.
A sensitive and specific method is described for the quantitative analysis of 6,11-dihydro-11-oxo-dibenz[b,e]oxepin-3-acetic acid (oxepinac) in human plasma, urine and saliva. Oxepinac and internal standard are extracted from acidified plasma, urine or saliva, converted to the corresponding n-propyl esters and analysed by gas chromatography—mass fragmentography using selected ion monitoring. The method is accurate and precise over the range 100 μg/ml to 1.0 ng/ml. The method has been applied to the analysis of plasma, urine and saliva from healthy volunteers receiving therapeutic doses of oxepinac.  相似文献   

18.
This report demonstrates the potential of on-line immunoaffinity extraction and coupled column packed capillary liquid chromatography-ion spray tandem mass spectrometry for multi-residue determination of five β-agonists, clenbuterol, mabuterol, mapenterol, methylclenbuterol, and tolubuterol, in bovine urine using an automated column switching system. Trace enrichment and preliminary sample cleanup was performed on-line using bovine urine diluted with phosphate-buffered saline. The column switching process involves trapping the target analytes onto a mini-bore immunoaffinity column, whereupon the target analytes are released from the immunoaffinity column onto a trapping column and subsequently eluted onto a packed capillary analytical column. The latter packed capillary column was used to provide the optimum sensitivity for ion spray LC-MS-MS analyses. The three-column system consists of a 2.0 mm I.D. immunoaffinity column, a 1 mm I.D. reversed-phase trapping column and a 320 μm I.D. packed capillary analytical column. Both qualitative and quantitative results are presented for the multi-residue determination of the target β-agonists from the complex urinary matrix. Using tolubuterol as an internal standard, the quantitative data showed good linear response within the concentration ranges studied. Lower levels of quantitation were 50 part per trillion (ppt) for clenbuterol and methylclenbuterol, 20 ppt for mabuterol and 10 ppt for mapenterol. The bovine renal elimination is described using the technique for one of the β-agonists, clenbuterol. The concentration of clenbuterol was detectable 15 days after the cessation of oral administration.  相似文献   

19.
Although a series of biomarkers are widely used for the estimation of oxidative damage to biomolecules, validations of the analytical methods have seldom been presented. Formal validation, that is the study of the analytical performances of a method, is however recognized as the best safeguard against the generation and publication of data with low reliability. Classical validation parameters were investigated for the determination of an oxidative stress biomarker, 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxo-dG) in cellular DNA, by high-performance liquid chromatography coupled to amperometric detection (HPLC-EC); this modified base is increasingly considered as a marker of oxidative damage to DNA, but many questions are still raised on the analytical methods in use. Upon a rigorous statistical evaluation of the quality criteria currently required for assays in biological media, including selectivity, linearity, accuracy, repeatability, sensitivity, limits of detection and quantification, ruggedness and storage at different stop points in the procedure, the HPLC-EC assay method is found mostly reliable.

The present validation attempt demonstrates that (i) the HPLC-EC assay of 8-oxo-dG provides consistent data allowing to reliably detect an increase of this biomarker in cellular DNA; (ii) a harsh oxidative stress does not hinder the enzymatic digestion of DNA by nuclease P1; and (iii) the analytical results must be expressed relative to the internal standard dG which significantly improves both repeatability and sensitivity. Whereas the described assay minimizes the artifactual production of the analyte from processing and storage, this cannot be totally ruled out; the true 8-oxo-dG base levels still lack a definitive assay method, which remains a considerable analytical challenge and the object of controversy.  相似文献   

20.
While ELISA is a frequently used means of assessing 8-oxo-7,8-dihydro-2-deoxyguanosine (8-oxodG) in biological fluids, differences in baseline urinary 8-oxodG levels, compared to chromatographic techniques, have raised questions regarding the specificity of immunoassays. Recently, ELISA of salivary 8-oxodG has been used to report on periodontal disease. We compared salivary 8-oxodG levels, determined by two commercial ELISA kits, to liquid chromatography-tandem mass spectrometry (LC-MS/MS) with prior purification using solid-phase extraction. While values were obtained with both ELISA kits, salivary 8-oxodG values were below or around the limit of detection of our LC-MS/MS assay. As the limit of detection for the LC-MS/MS procedure is much lower than ELISA, we concluded that the assessment of salivary 8-oxodG by ELISA is not accurate. In contrast to previous studies, ELISA levels of urinary 8-oxodG (1.67 ± 0.53 pmol/μmol creatinine) were within the range reported previously only for chromatographic assays, although still significantly different than LC-MS/MS (0.41 ± 0.39 pmol/μmol creatinine; p = 0.002). Furthermore, no correlation with LC-MS/MS was seen. These results question the ability of ELISA approaches, at present, to specifically determine absolute levels of 8-oxodG in saliva and urine. Ongoing investigation in our laboratories aims to identify the basis of the discrepancy between ELISA and LC-MS/MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号