首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A high-performance liquid chromatography (HPLC) method was developed for quantification of both isomers of the thioxanthene neuroleptic flupentixol and of the butyrophenone derivative haloperidol in human serum. After extraction with diethyl ether–n-heptane (50:50, v/v), an isocratic normal-phase HPLC system with a Hypersil cyanopropyl silica column (250×4.6 mm, 5 μm particle size) was used with ultraviolet detection at 254 nm and elution with a mixture of 920 ml acetonitrile, 110 ml methanol, 30 ml 0.1 M ammonium acetate, and 50 μl triethylamine. The limit of quantitation of 0.5 ng/ml and 0.3 ng/ml for flupentixol and haloperidol, respectively, was sufficient to quantify both compounds in serum after administration of clinically adjusted doses. The suitability of the described method for therapeutic drug monitoring and clinical pharmacokinetic studies was assessed by analysis of more than 100 trough level serum samples.  相似文献   

2.
A simple method is described for the determination of the cyclooxygenase-2 specific inhibitor celecoxib in human serum by HPLC using the demethylated analogue as internal standard. After protein precipitation with acetonitrile, samples were extracted with chloroform. Separation was achieved on a Prontosil C18 AQ column (150x3 mm I.D., 3-microm particle size) at a flow-rate of 0.35 ml/min using water-acetonitrile (40:60, v/v) as the mobile phase. Using fluorescence detection with excitation at 240 nm and emission at 380 nm, the limit of quantification was 12.5 ng/ml for a sample size of 0.5 ml of serum. The assay was linear in the concentration range of 12.5-1500 ng/ml and showed good accuracy and reproducibility. At all concentrations intra- and inter-assay variabilities were below 11% with less than 9% error. The method was applied to the determination of celecoxib for pharmacokinetic studies in man.  相似文献   

3.
A rapid and simple HPLC method with UV detection (288 nm) was developed and validated for quantitation of niflumic acid in human plasma, the active metabolite of talniflumate. After precipitation with 100% methanol containing the internal standard, indomethacin, the analysis of the niflumic acid level in the plasma samples was carried out using a reverse phase C18 CAPCELL PAK (5 microm, 4.6 mm x 250 mm) column. The chromatographic separation was accomplished with an isocratic mobile phase consisting of a mixture of 0.1M sodium acetate in water and acetonitrile (37:63, v/v), adjusted to pH 6.4. This HPLC method was validated by examining its precision and accuracy for inter- and intra-day runs in a linear concentration range of 0.02-5.00 microg/mL. Stability of niflumic acid in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method was successfully applied to the bioequivalence study of talniflunate in healthy volunteers.  相似文献   

4.
A sensitive and reproducible high performance liquid chromatography method with UV detection was described for the determination of aesculin in rat plasma. After deproteinization by methanol using metronidazole as internal standard (I.S.), solutes were evaporated to dryness at 40 degrees C under a gentle stream of nitrogen. The residue was reconstituted in 100 microl of mobile phase and a volume of 20 microl was injected into the HPLC for analysis. Solutes were separated on a Diamonsil C18 column (250 mm x 4.6 mm i.d., 5 microm particle size, Dikma) protected by a ODS guard column (10 mm x 4.0 mm i.d., 5 microm particle size), using acetonitrile-0.1% triethylamine solution (adjusted to pH 3.0 using phosphoric acid) (10:90, v/v) as mobile phase (flow-rate 1.0 ml/min), and wavelength of the UV detector was set at 338 nm. No interference from any endogenous substances was observed during the elution of aesculin and internal standard (I.S., metronidazole). The retention times for I.S and aesculin were 10.4 and 12.4 min, respectively. The limit of quantification was evaluated to be 57.4 ng/ml and the limit of detection was 24.0 ng/ml. The method was used in the study of pharmacokinetics of aesculin after intraperitoneal injection (i.p.) administration in rats.  相似文献   

5.
A simple, rapid and sensitive high-performance liquid chromatography (HPLC) method was developed for the enantioselective analysis of the new antidepressant drug mirtazapine in human plasma. The procedure involved liquid-liquid extraction using toluene, followed by liquid chromatography coupled to UV detection at 292 nm. The chromatographic separation of the (+)-(S)- and (-)-(R)-enantiomers of mirtazapine was achieved on a Chiralpak AD column (250 mm x 4.6 mm, 10 microm particle size) protected with a CN guard column, using hexane-ethanol (98:2, v/v) plus 0.1% diethylamine as the isocratic mobile phase, at a flow rate of 1.2 ml/min. The total analysis time was less than 12 min per sample. The recoveries of (+)-(S)- and (-)-(R)-mirtazapine were in the 88-111% range with a linear response over the 6.25-625 ng/ml concentration range for both enantiomers. The quantification limit (LOQ) was 5 ng/ml. Within-day and between-day assay precision and accuracy were studied at three concentration levels (10, 50 and 250 ng/ml). For both mirtazapine enantiomers, the coefficients of variation (CV) and deviation from the theoretical value were lower than 15% at all concentration levels. The method proved to be suitable for pharmacokinetic studies.  相似文献   

6.
An HPLC method for determining a flavonoid, naringin, and its metabolite, naringenin, in human plasma is presented for application to the pharmacokinetic study of naringin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using genistin (for naringin) or daidzein (for naringenin) as an internal standard and solid-phase extraction using a Sep-Pak t C18 cartridge. For the determination, HPLC was carried out using an Inertsil ODS-2 column (250x4.6 m I.D., 5 μm particle size). The mobile phases were acetonitrile-0.1 M ammonium acetate solution (20:80, v/v; pH 7.1) for naringin and acetonitrile-0.1 M ammonium acetate solution-acetic acid (30:69:1, v/v; pH 4.9) for naringenin. The flow-rate was 1 ml min−1. The analyses were performed by monitoring the wavelength of maximum UV absorbance at 280 nm for naringin and at 292 nm for naringenin. The detection limits on-column were about 0.2 ng for the two flavonoids.  相似文献   

7.
Two simple, rapid and sensitive methods, namely, fourth‐derivative synchronous spectrofluorimetry (method I) and HPLC with fluorescence detection (method II) were developed for the simultaneous analysis of a binary mixture of itopride HCl (ITP) and domperidone (DOM) without prior separation. The first method was based on measuring the fourth derivative of the synchronous fluorescence spectra of the two drugs at Δλ = 40 nm in methanol. The different experimental parameters affecting the synchronous fluorescence of the studied drugs were carefully optimized. Chromatographic separation was performed in < 6.0 min using a RP C18 column (250 mm × 4.6 mm i.d., 5 µm particle size) with fluorescence detection at 344 nm after excitation at 285 nm. A mobile phase composed of a mixture of 0.02 M phosphate buffer with acetonitrile in a ratio of 55 : 45, pH 4.5, was used at a flow rate of 1 mL/min. Linearity ranges were found to be 0.1–2 µg/mL for ITP in both methods, whereas those for DOM were found to be 0.08–2 and 0.05–1.5 µg/mL in methods I and II, respectively. The proposed methods were successfully applied for the determination of the studied drugs in synthetic mixtures and laboratory‐prepared tablets. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
A reversed-phase high-performance liquid chromatographic method for the detection of boronophenylalanine is described. Determination was obtained by precolumn reaction of o-phthalaldehyde with a mixture of standard amino acids containing boronophenylalanine and separating the corresponding o-phthalaldehyde derivatives, using a Kromasil C-18, 250 x 4.6 mm, 5-microm particle size column, a step gradient with two buffers, a flow rate of 1.2 ml/min, a column temperature of 23 degrees C, and fluorimetric detection (excitation and emission wavelengths of 330 and 430 nm, respectively). The use of such a method for assaying boronophenylalanine in biological samples was tested in neutralized perchloric acid blood and cerebral tissue extracts of rats treated with intracarotid administration of 300 mg/kg of body weight boronophenylalanine. Results of these experiments showed that the present HPLC method represents a valid alternative to currently available analytical techniques for assaying boronophenylalanine based on boron determination in terms of reproducibility, recovery, or sensitivity. Therefore, it is suggested that the present method may routinely be used in all preclinical and clinical studies in which quantification of circulating and tissue concentrations of boronophenylalanine is critical for the application of boron neutron capture therapy.  相似文献   

9.
10.
Achiral and chiral HPLC methods were developed for clinafloxacin, a quinolone antimicrobial agent. For achiral assay, analytes were isolated from plasma by precipitating plasma proteins. Separation was achieved on a C18 column using an isocratic eluent of ion pairing solution–acetonitrile (80:20, v/v) at 1.0 ml/min with UV detection at 340 nm. The ion pairing solution was 0.05 M citric acid, 1.15 mM tetrabutylammonium hydroxide and 0.1% ammonium perchlorate. Inter-assay accuracy was within 4.9% with an inter-assay precision of 3.7% over a quantitation range of 0.025 to 10.0 μg/ml. For chiral assay, analytes were isolated from plasma by solid-phase extraction. Separation was achieved on a Crownpak CR(+) column using an isocratic eluent of water–methanol (88:12, v/v) containing 0.1 mM decylamine at 1.0 ml/min with UV detection at 340 nm. Perchloric acid was added to adjust pH to 2. Inter-assay accuracy was within 3.5% with a inter-assay precision of 5.4% over a quantitation range of 0.040 to 2.5 μg/ml.  相似文献   

11.
A high-performance liquid chromatographic method for the measurement of bumetamide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol—water—glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5–2000 ng/ml.  相似文献   

12.
Ebastine (CAS 90729-43-4) is an antiallergic agent which selectively and potently blocks histamine H1-receptors in vivo. A simple and sensitive high-performance liquid chromatography (HPLC) method is described for the simultaneous determination of ebastine and its two oxidized metabolites, carebastine (CAS 90729-42-3) and hydroxyebastine (M–OH), in human plasma. After a pretreatment of plasma sample by solid-phase extraction, ebastine and its metabolites were analyzed on an HPLC system with ultraviolet detection at 254 nm. Chromatography was performed on a cyano column (250×4.0 mm I.D.) at 40 °C with the mobile phase of acetonitrile–methanol–0.012 M ammonium acetate buffer (20:30:48, v/v/v) at a flow rate of 1.2 ml/min. Accurate determinations were possible over the concentration range of 3–1000 ng/ml for the three compounds using 1 ml plasma samples. The intra- and inter-day assay accuracy of this method were within 100±15% of nominal values and the precision did not exceed 12.4% of relative standard deviation. The lower limits of quantitation were 3 ng/ml for ebastine and its metabolites in human plasma. This method was satisfactorily applied to the determination of ebastine and its two oxidized metabolites in human plasma after oral administration of ebastine.  相似文献   

13.
We present a simple, fast and validated method for the determination of the new generation antiepileptic drug (AED) levetiracetam (LEV) in plasma of patients with epilepsy using high performance liquid chromatography (HPLC) with UV detection. Plasma sample (500 microL) pretreatment was based on simple deproteinization by methanol spiked with the internal standard (I.S.). HPLC analysis was carried out on a Synergi 4-microm Hydro-RP, 150 mm x 4 mm I.D. column. The mobile phase was a mixture of potassium dihydrogen phosphate buffer (50 mM, pH 4.5) and acetonitrile (94:6, v/v) at an isocratic flow rate of 1.5 mL/min. The UV detector was set at 205 nm. Calibration curves were linear (mean correlation coefficient=0.999) over a range of 4-80 microg/mL. The quantitation limit was 2 microg/mL and the absolute recovery was >90% for LEV and the I.S. Both intra and interassay precision and accuracy were lower than 7.5%. The chromatographic run lasted 13 min. The present procedure omitting expensive solid phase or time-consuming liquid-liquid extraction and drying steps is cheaper, faster and simpler than mostly published analytical methods for levetiracetam. Applied to a large population of patients with epilepsy this assay proved very practical in our therapeutic drug monitoring setting (TDM).  相似文献   

14.
A high-performance liquid chromatographic method for the determination of trimetazidine dihydrochloride (TMZ) in spiked human plasma is described. The method is based on the pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) using the fluorimetric detection technique. Fluoxetine HCl (FLX) was used as internal standard. Both, TMZ and FLX were completely derivatized after heating at 50 degrees C for 20 min in borate buffer pH 8.0. Samples were analyzed by high performance liquid chromatography (HPLC) using Zorbax-TMS column (250 mm x 4.6 mm, i.d., 5 microm) and mobile phase consist of acetonitrile, methanol and 20 mM sodium acetate pH 4.7 (44:6:50; v/v/v). Fluorescence detector (FLD) was adjusted at excitation and emission wavelengths; 265 and 311 nm, respectively. The linearity of the method was in the range of 4.5-200 ng/ml. Limits of detection (LOD) and quantification (LOQ) were 1.5 and 4.5 ng/ml, respectively. Trimetazidine recovery was 96.5+/-1.3% (n=6; RSD=2.1%).  相似文献   

15.
Two different columns—Lux Cellulose-1 and Chiralpak CBH—were evaluated for their chiral recognition abilities for eight drugs comprising three β-blockers, one antacid, and four cathinones in polar-organic elution mode and reversed-phase elution mode, respectively. The factors that affected the enantioseparation were tested and optimized to develop a suitable chiral separation method whose LC conditions are compatible with MS detection. In polar-organic elution mode with the Lux Cellulose-1 column, methanol and acetonitrile were tested as the main components of the mobile phase. In addition, the effects of adding isopropanol as organic modifier, acidic additives (formic acid), and basic additives (diethylamine) were evaluated. In reversed-phase elution mode with the Chiralpak CBH column, the effect of type and concentration of organic modifier (isopropanol, acetonitrile, and methanol), the mobile phase pH (6.4 and 5.0), and buffer concentration (1mM-20mM ammonium acetate) were evaluated. The best enantioseparation was achieved with the Chiralpak CBH column with a mobile phase composed of 5mM ammonium acetate aqueous (pH = 6.4)/methanol (95/5, v/v) at a flow rate of 0.1 mL/min and a temperature of 30°C. Under these conditions, six of eight chiral drugs were baseline separated.  相似文献   

16.
The aim of this study was to develop a rapid and sensitive HPLC method with UV detection for the estimation of imatinib from the plasma of patients with chronic myeloid leukemia (CML). The robustness of the method was checked by conducting first dose pharmacokinetics on blood samples from four patients who had been administered Gleevec (100 mg) in an oral dose. Samples were prepared in a simple and single step by precipitating the plasma proteins with methanol and injecting 50 microl aliquot from supernatant was subjected for analysis. Assay was conducted using a C8 column (250 mm x 4.6 mm, 5 microm particle size) under isocratic elution with 0.02 M potassium dihydrogen phosphate-acetonitrile (7:3, v/v) at a flow rate of 1 ml/min and detected using photodiode array at 265 nm. Calibration plots in spiked plasma were linear in a concentration range of 0.05-25 microg/ml. The inter and intra-day variation of standard curve was <4% (R.S.D.). This method could be a simple and quick method for the estimation of imatinib from the patient's plasma.  相似文献   

17.
A high-performance liquid chromatographic assay with MS detection has been developed for the quantitative determination of the anti-angiogenic agent CC-5013 in human plasma. Sample pretreatment involved liquid-liquid extraction with acetonitrile/1-chlorobutane (4:1, v/v) solution containing the internal standard, umbelliferone. Separation of the compounds of interest was achieved on a column packed with Waters C18 Nova-Pak material (4 microm particle size; 300 mm x 3.9 mm internal diameter) using acetonitrile, de-ionized water, and glacial acetic acid in ratios of 20:80:0.1 (v/v/v) (pH 3.5) delivered at an isocratic flow rate of 1.00 ml/min. Simultaneous MS detection was performed at m/z 260.3 (CC-5013) and m/z 163.1 (umbelliferone). The calibration curve was fit to a linear response-concentration data over a range of 5-1000 ng/ml using a weighting factor of 1/x. Values for accuracy and precision, obtained from four quality controls analyzed on three different days in replicates of five, ranged from 98 to 106% and from 5.5 to 15.5%, respectively. The method was successfully applied to study the pharmacokinetics of CC-5013 in a cancer patient receiving the drug as single daily dose.  相似文献   

18.
A procedure for determination of rifampicin and 25-desacetylrifampicin in plasma by HPLC was developed. The plasma proteins are precipitated by acetonitrile and the supernatant layer (50 microliters) is used for the assay under isocratic conditions on an analytical column 250 x 4.6 mm in size containing the reversed phase sorbent (C18). The size of the precolumn is 50 x 4.6 mm. An UV detector (at lambda 335 nm) is used. For preparing the mobile phase 630 ml of methanol and 370 ml of 0.058 M sodium nitrite solution are mixed. The flow rate of the mobile phase is 40.7 ml/min. The assay duration is about 10 min. The retention time is 9.6 min for rifampicin and 6.5 min for 25-desacetylrifampicin. The minimum detectable amount of the antibiotic and its metabolite is 0.10 micrograms/ml. The standard curves of rifampicin and 25-desacetylrifampicin are linear within the concentration ranges of 0.5-100 and 0.5-10 micrograms/ml respectively. The procedure is useful in studies on pharmacokinetics of rifampicin and 25-desacetylrifampicin.  相似文献   

19.
An improved method suitable for the determination of 8-methoxypsoralen in the range 50–1500 ng/ml in the plasma of psoriatic patients undergoing PUVA (psoralens and long-wave ultraviolet light) therapy is proposed. A 5-ml aliquot of plasma containing sodium citrate as anticoagulant was centrifuged, griseofulvin was added as internal standard and the sample was denatured with acetonitrile. The supernatant was applied to C18 cartridges and 8-methoxypsoralen was eluted with methanol. The evaporated eluate was reconstituted in the mobile phase for high-performance liquid chromatography (HPLC) and applied to the HPLC column: mobile phase, acetonitrile—0.01 M phosphoric acid (34:66); flow-rate, 1 ml/min; temperature, 40°C; column, Spherisorb 5 ODS, 100 mm × 4.6 mm I.D., 5 μm particle size; UV detection at 248 nm; detection limit, 15 ng/ml of plasma.  相似文献   

20.
We present new HPLC methods for the quantitation in human plasma of two investigative metallotexaphyrin agents, motexafin gadolinium (Gd-Tex) and motexafin lutetium (Lu-Tex). Each assay uses: the other texaphyrin analogue as an internal standard; protein precipitation with acetonitrile:methanol (50:50, v/v); an ODS reversed-phase column; an isocratic mobile phase of 100 mM ammonium acetate, pH 4.3:acetonitrile:methanol (59:21:20, v/v/v); and absorbance detection at 470 nm. The Gd-Tex assay has a lower limit of quantitation (LLOQ) of 0.01 μM and is linear between 0.01and 30 μM. The Lu-Tex assay has an LLOQ of 0.1 μM and is linear between 0.1 and 30 μM. The assays are suited for in vivo preclinical studies and clinical trials because they require minimal amounts of plasma, are sensitive, and involve a 30-min run time. These assays are important tools for evaluating the potential of Gd-Tex and Lu-Tex as a radiation enhancer and photosensitizer, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号